The full rack and half rack vertical mount monitored PDUs provide customers a full rack of power with local monitoring and easily accessible at the rear of the rack.

» Performance
» Customer choice
» Monitoring
» Color-coded load segments

Product information

» Overview & Features
» Key benefits
» Questions & Answers

Performance

With both single-phase or three-phase power and output power ranging from 4.9 kVA up to 22.1 kVA per PDU, the amount of equipment connected to a single PDU is significantly increased over existing PDU products available. Additional customer choice of single feed or dual feed models allow for power redundancy as well as increased outlet count (Full rack vertical mount models with either 39 receptacles per single feed model, or 78 receptacles per dual feed model; half rack vertical mount models with twelve C-19 receptacles for 3 phase versions, and single phase versions have 24 C-13 and three C19 receptacles).


Customer choice

Full rack vertical PDU

Models consist of single feed or dual feed models allowing for power redundancy as well as increased outlet count (either 39 receptacles per single feed model or 78 receptacles per dual feed model).




Along with the product choices comes the requirement to be sure and have your data center able to accommodate the correct input power. Below are the types of input plugs available on the full rack vertical PDU models.




Half rack vertical PDU

Models consist of single feed model with twelve C-19 outlets

Half rack vertical PDU

Along with the product choices comes the requirement to be sure and have your data center able to accommodate the correct input power. Below are the types of input plugs on the available on the half rack vertical PDU models.

IEC 309 4-pin 60A plug-Model S348 IEC 309 5-pin 32A plug-Model S332



Monitoring

The front panel has a two-digit, seven segment LED digital display, which shows the current in each circuit breaker, a scroll button to scroll through values, and six LEDs, which indicate current overloads and voltage out of range conditions. Current monitoring consists of two digit RMS current, with load segment LEDs reporting three different conditions (normal 0-80%; caution 80-102%; warning > 102%). Voltage monitoring measures over voltage and under voltage on any output load segment.



Color-coded load segments

Both the front panel receptacles and circuit breakers are color coded by load segment for easy and quick identification and matching. Load segments are also spread across the length of the PDU for equal distribution in a rack. Flat rocker circuit breakers provide additional security by preventing accidental shut off (smooth/flush to PDU surface when on).