The HP BladeSystem PCI Expansion Blade provides PCI card expansion slots to an adjacent c-Class blade server. This blade expansion unit uses the c-Class midplane to pass standard PCI signals between adjacent enclosure bays, to allow a c-Class blade server to add off-the-shelf PCI-X or PCI-e cards. Customers would need one PCI Expansion Blade for each c-Class server blade needing PCI card expansion. Any PCI card from third-party manufacturers that works in HP ProLiant ML and HP ProLiant DL servers should work in this PCI Expansion Blade. HP does not offer any warranty or support for third-party PCI manufactured products. HP does joint market with selected PCI manufactures via the HP BladeSystem Solutions Builder Program.
|
 |
|
 |
 |
|
 |
 |
 |
Provides PCI-X or PCI-e expansion slots for c-Class blade server in an adjacent enclosure bay.
- Each PCI Expansion Blade can hold one or two PCI-X cards( 3.3V or universal); or one or two PCI-e cards(x1, x4, or x8)
- Installed PCI-X cards must use less than 25 watts per card. Installed PCIe cards must use less than 75 watts per PCIe slot, or a single PCIe card can use up to 150 watts, with a special power connector enabled on the PCI Expansion blade.
- Supports typical third-party (non-HP) PCI cards, such as SSL or XML accelerator cards, VOIP cards, special purpose telecommunications cards, and some graphic acceleration cards.
|
 |
|
 |
 |
 |
Ideal for...
- Applications requiring hardware acceleration using PCI cards
- Applications needing special-purpose telecommunications cards
- Applications needing other third-party PCI-X or PCI-e cards
|
 |
|
 |
 |
 |
 |
|
| HP BladeSystem PCI Expansion blade |
Dimensions Height 2.207in (5.61cm)
Depth 20.058in (50.95cm)
Width 7.154 in (18.17cm)
Weight Maximum 14.20 lb (6.44kg)
Temperature Range* Operating: 10°C to 35°C (50°F to 95°F)
Non-Operating:-40°C to 60°C (-40°F to 140°F)
Storage:-20°C to 60°C (-4 to 140°C)
Maximum Wet Bulb Temperature:-30°C (86°F)
Operating:10% to 90%
Relative Humidity** Shipping: 10% to 90%
Storage: 10% to 95%
*NOTE: All temperature ratings shown are for sea level. An altitude derating of 1°C
per 304.8 m (1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct
sunlight allowed. Upper operating limit is 3,048m (10,000 ft) or 70 Kpa/10.1 psia.
Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia.
**NOTE: Storage maximum humidity of 95% is based on a maximum temperature
of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum
of 70 KPa.
|
|
|