Overview
|
Smart Array 5300 Controller |
| The Smart Array 5300 series of high-performance
Ultra3 array controllers provides reliable data protection for ProLiant
servers and offers new levels of flexibility thanks to an innovative modular
design and new Advanced Data Guarding (RAID ADG) technology. The Smart Array
5300 controller raises the standard to higher performance levels with several
enhancements including a new memory architecture and new RAID engine.
Designed and tested with industry-standard ProLiant Servers for greater reliability, this controller is ideal for the distributed workgroup server or centralized departmental server, and like other Smart Array controllers, the SA-5300 offers complete data compatibility with previous generations' Smart Array controllers for easy data migration and upgradability. |
|
|
| What's New | ||||||||
| Updated option support list | ||||||||
|
|
||||||||
| Models | |
| Smart Array 5304/256 Controller |
283551-B21
|
| Smart Array 5304/256 Controller (Japan) |
283551-291
|
|
|
|
| Related Options | |
| NOTE: This is a list of related options, some may be discontinued. | |
| Smart Array 5302/128 Controller |
283552-B21
|
| Smart Array 5302/128 Controller (Japan) |
283552-291
|
| SAN Access Module for Smart Array 5302 Controller |
216687-B21
|
| SAN Access Module for Smart Array 5302 Controller (Japan) |
216687-291
|
|
|
|
| Feature List |
|
|
|
| Key Features |
|
|
|
| The Smart Array Advantage | ||||||
| HP's innovative design and integration work of the Smart Array family of products creates customer value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID products. The HP Smart Array family brings an unparalleled return on investment through: | ||||||
|
|
|
Product Highlights
|
Data Compatibility |
Data compatibility among all models of Smart Array Controllers means customers can instantly upgrade their Smart Array products to get to higher performance, capacity and availability. Unlike competitive products, successive generations of Smart Array products understand the data format of other Smart Array controllers, providing investment protection for your HP storage solution. | ||
|
|
|||
|
Performance |
HP's High Performance Architecture sets new boundaries of industry performance expectations! | ||
|
|||
|
|
|||
| Capacity | Given the need for scalable capacity growth of server storage, the SA-5300 offers up to four SCSI channels for over two terabytes of storage from a single PCI slot: |
|
|
|
|
|
|
Availability |
Provides increased server uptime by providing advanced storage functionality: | ||
|
|||
|
|
|||
|
Fault Prevention |
The following features offer detection of possible failures before they occur, allowing preventive action to be taken: | ||
|
|||
|
|
|||
|
Fault Tolerance |
Keeps data available and server running while a failed drive is being replaced; several fault tolerance configurations are supported including: | ||
|
|||
|
|
|||
|
Fault Recovery |
Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure | ||
|
|||
|
|
|||
| Ease of Use | Consistency and Upgradability make the Smart Array family unique in the industry: | |
|
||
|
|
||
|
SAN Access (Optional) |
The SAN Access Module for the Smart Array 5302 Controller offers the industry's first true integrated bridge from Direct Attach Storage (SCSI) to the Fibre Channel Storage Area Network (SAN). Fibre Channel SAN offers robust data handling for superior reliability and manageability. Smart Array SAN Access Technology grants users of SCSI based storage the opportunity to implement a basic SAN for the consolidation of backup operations with HP Enterprise Backup Solutions (ARCPaq or BackPaq). SAN Access Technology also offers access to primary storage (RAID Array 4100) on the SAN. |
| Key Features: | |
|
|
|
Compatibility
| Server Compatibility |
| For up to date compatibility, please see the following URL for complete Smart Array 5300 compatibility and support information: http://www.hp.com/products/smartarray |
|
|
| Operating Systems | |||
| Microsoft Windows NT 4.0, 2000, 2003** | |||
| Novell NetWare 4.2, 5.x ** | |||
| SCO UnixWare 7.1.x | |||
| SCO UnixWare 8 | |||
| SCO OpenServer 5.0.4, 5.0.5, 5.0.6a | |||
| Linux | |||
| IBM OS/2 Warp Server 4 | |||
| IBM OS/2 Warp Server for e-Business | |||
| Sun Solaris™ * Intel Platform Edition 7 | |||
| Sun Solaris™ * Intel Platform Edition 8 | |||
| **SAN Access module compatible with Operating System. | |||
|
|
|||
| Software Suite |
|
All Smart Array products share a common set of configuration, management and diagnostic tools, including Array Configuration Utility XE (ACU-XE), Array Configuration Utility (ACU), Array Diagnostic Utility (ADU), and Insight Manager. This software consistency of tools reduces the cost of training for each successive generation of product and takes much of the guesswork out of troubleshooting field problems. These tools lower the total cost of ownership by reducing training and technical expertise necessary to install and maintain the HP server storage. |
| HP Insight Manager |
|
| Configuration/Diagnostic Utilities |
|
|
|
Service and Support, HP Care Pack, and Warranty Information
| Software Product Services |
Standalone telephone support
|
| Rights to new license version | |
| Media and documentation updates | |
|
|
|
| Hardware Product Services | Installation services |
| On-site maintenance (includes warranty support) | |
| Response time upgrades during the warranty period | |
| Post-warranty coverage | |
| RAID setup and performance consulting via statement of work | |
| For additional hardware installation
and maintenance information, please refer to the URL listed below: http://www.hp.com/hps/hardware/ |
|
|
|
|
| Warranty Upgrade Options | Response - Upgrade on-site response from next business day to same day 4 hours |
| Coverage - Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days | |
| Duration - Select duration of coverage for a period of 1, 3, or 5 years | |
|
|
|
| HP Care Pack Information | HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage. | |
| HP Care Pack is not available for less than the product's warranty duration. | ||
| HP Care Pack is available for sale anytime during the warranty period for most products, but the commencement date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase may be required. | ||
| HP Care Pack services are prepaid. | ||
| For additional HP Care Pack (hardware & software) information, as well as orderable part numbers, please refer to the URL http://www.hp.com/hps/carepack/ | ||
|
|
Options
| Software | StorageWorks Virtual Replicator by HP | |||
| License & Media (CD-ROM) | 388931-B21 | |||
| License Only | 388932-B21 | |||
|
|
||||
| Disk Drive Enclosures | HP StorageWorks Modular Smart
Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies |
302969-B21
|
|
| HP StorageWorks Modular Smart
Array 30 DB NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies |
302970-B21 | ||
|
|
|||
| Hard Drives | Ultra320 Universal Drives Hot Plug | ||
| 36.4GB 10,000 rpm, U320 Universal Hard Drive, 1" | 286713-B22 | ||
| 72.8GB 10,000 rpm, U320 Universal Hard Drive, 1" | 286714-B22 | ||
| 146.8GB 10,000 rpm, U320 Universal Hard Drive, 1" | 286716-B22 | ||
| 300GB 10,000 rpm, U320 Universal Hard Drive, 1" | 350964-B22 | ||
| 18.2GB 15,000 rpm, U320 Universal Hard Drive, 1" | 286775-B22 | ||
| 36.4GB 15,000 rpm, U320 Universal Hard Drive, 1" | 286776-B22 | ||
| 72.8GB 15,000 rpm, U320 Universal Hard Drive, 1" | 286778-B22 | ||
| NOTE:
This is a list of supported hard disk drives (note that some
drives may be discontinued). NOTE: For complete compatibility information, refer to the SCSI Hard Drive Compatibility table located at: http://www.compaq.com/products/servers/proliantstorage/drives-enclosures/docs/index.html |
|||
|
|
|||
| Universal Hot Plug Tape Drives | HP StorageWorks DAT 72 Tape Drive, Internal Hot-Plug (Carbon) |
Q1529A
|
| HP StorageWorks DAT 40 Tape Drive, Internal Hot-Plug (Carbon) |
Q1546A
|
|
|
Family Information
| This is a brief overview and comparison of the Smart Array family of PCI RAID controllers. |
| Smart Array 5302/5304 | Smart Array 5312 | Smart Array 4300 | Smart Array 532 | |
| Introduction Date | July 2000 | April 2002 | July 1999 | May 2001 |
| SCSI Protocols Supported | Ultra3, Ultra2, Wide-Ultra |
Ultra3, Ultra2 | Ultra2, Wide-Ultra | Ultra3, Ultra2 |
| Maximum Channel Transfer Rate (MB/s) | 640 total 160 per channel |
320 total 160 per channel |
320 total 80 per channel |
320 total 160 per channel |
| Channels | 2, 4 | 2 | 4 | 2 |
| SCSI Ports (external/internal) | 2 channel model: 2/2 4 channel model: 4/2 |
2/2 | 4/2 | 1/1 |
| Maximum Drives | 56* | 28* | 56* | 20* |
| Cache | 256-, 128-, 64- or 32-MB read-write |
128-MB read-write | 64-MB read-write | 32-MB read cache |
| Battery-backed, Removable Cache | Yes, Redundant , Replaceable Batteries |
Yes, Redundant , Replaceable Batteries |
Yes | No |
| Upgradeable Cache | Yes | Yes | No | No |
| Recovery ROM | Yes | Yes | No | Yes |
| RAID Support | 0,1,1+0,5, Advanced Data Guarding** |
0,1,1+0,5 | 0,1,1+0,5 | 0,1, 1+0,5 |
| Configuration Tool(s) | ACU-XE ACU ORCA |
ACU-XE ACU ORCA |
ACU-XE ACU |
ACU-XE ACU ORCA |
| Management and Diagnostic Tools | CIM ADU |
CIM ADU |
CIM ADU |
CIM ADU |
| Maximum Volumes | 32 | 32 | 32 | 32 |
| Drive Roaming | Yes | Yes | Yes | Yes |
| Online Expansion | Yes | Yes | Yes | Yes |
| Online & Offline Configuration | Yes | Yes | Yes | Yes |
| Logical Drive Extension | Yes | Yes | Yes | Yes |
| Stripe Set Migration | Yes | Yes | Yes | Yes |
| RAID Level Migration | Yes | Yes | Yes | Yes |
| Redundant Controllers | No | No | No | No |
| Online Spare Support | Yes | Yes | Yes | Yes |
| Capacity Extension | Yes | Yes | Yes | Yes |
| SAN Access Module | Yes | No | No | No |
| PCI Bus | 64-bit, 66-MHz | 64-bit, 133-MHz PCI-X | 32-bit, 33-MHz | 64-bit, 66-MHz |
| *NOTE: Based on use of StorageWorks Enclosure 4200/4300 family (14 drives enclosure) | |||||
| **NOTE: RAID ADG is a standard feature of SA-5304 and available as an option to other models. RAID ADG requires a minimum of 64-MB battery-backed cache. | |||||
|
|
Configuration Information
| Building a Storage Sub-System with the Smart Array 5300 Controller | ||||
| Step 1 Smart Array 5300 Choose a Model | ||||
| Select one: | ||||
| Model Number | Part Number | Model Description | ||
| SA-5304/256 | 283551-B21 | Smart Array 5304/256 Controller | ||
| 283551-291 (Japan) | Ultra3 2 channel PCI Array Controller board, | |||
| Ultra3 2 channel Expansion Module, | ||||
| 256-MB Cache Module, | ||||
| Advanced Data Guarding, | ||||
| Setup and configuration software, | ||||
| Documentation | ||||
|
|
||||
| Step 2 Additional Options | |
| Select each required option with quantities specified. | |
| Part Number | Description with Parts Shipped: |
| 286713-B22 | 36.4GB 10,000 rpm, U320 Universal Hard Drive, 1" |
| 286714-B22 | 72.8GB 10,000 rpm, U320 Universal Hard Drive, 1" |
| 286716-B22 | 146.8GB 10,000 rpm, U320 Universal Hard Drive, 1" |
| 350964-B2 | 300GB 10,000 rpm, U320 Universal Hard Drive, 1" |
| 286775-B22 | 18.2GB 15,000 rpm, U320 Universal Hard Drive, 1" |
| 286776-B22 | 36.4GB 15,000 rpm, U320 Universal Hard Drive, 1" |
| 286778-B22 | 72.8GB 15,000 rpm, U320 Universal Hard Drive, 1" |
| Q1529A | HP StorageWorks DAT 72 Tape Drive, Internal Hot-Plug (Carbon) |
| Q1546A | HP StorageWorks DAT 40 Tape Drive, Internal Hot-Plug (Carbon) |
| NOTE: This is a list of additional supported options some may be discontinued. | |
|
|
Technical Specifications
| Electrical Interface | LVD (Low Voltage Differential) and SE (Single Ended) | |
| Protocol Support | Wide Ultra3 SCSI (160 MB/s per channel) | |
| SCSI Ports | 4 channel model: 4 external/2 Internal shared | |
| 2 channel model: 2 external/2 internal shared | ||
| Drives Supported | 4 channel model: up to 56 drives | |
| 2 channel model: up to 28 drives | ||
| Maximum Capacity | 4 channel model: 16.8 TB (56 drives x 300 GB) | |
| 2 channel model: 8.4 TB (28 drives x 300 GB) | ||
| PCI | PCI 2.2 Compliant | |
| PCI Bus Speed | 64-bit, 66-MHz PCI (533-MB/s maximum bandwidth) | |
| Logical Drives | Up to 32 logical drives Up to 2TB per Logical Drive |
|
| RAID Support | RAID ADG (Advanced Data Guarding)* included with model SA-5304 | |
| RAID 5 (Distributed Data Guarding) | ||
| RAID 1+0 (Striping & Mirroring) | ||
| RAID 0 (Striping) | ||
| Cache Memory | Up to 256-MB Write Cache Memory (32-, 64-, 128-MB and 256-MB modules) | |
| ECC protection, battery-backed, and removable | ||
| SA-5302/FC comes standard with 32-MB cache memory | ||
| Cache Batteries | Up to 4 days of redundant battery life, removable for easy replacement (3days with 256-MB Module) | |
| Upgradable Firmware | 2-MB flashable ROM | |
| Disk Drive and Enclosure Protocol Support | Ultra3, Ultra2 and Wide-Ultra (SCSI-3) | |
| Memory Addressing | 64-bit, supporting servers memory greater than 4 GB | |
| Dimensions (HxWxD) | 18.375 x 8.25 x 4 in (46.67 x 20.95 x 10.16 cm) | |
| Weight | Smart Array 5304/256 | 3.26 lbs (1.48 kg) |
|
|
||
| SAN Access Module Specifications | |||
| Fibre Channel Protocol Support ** | 1-Gbit Fibre Channel | ||
| Fibre Channel Ports ** | 1 | ||
| EBS Qualification ** | ARCPaq and BackPaq | ||
| NOTE: Only with single (non-cascaded) 7 or 12 Port Fibre Channel Hub and FC-AL Switch 8. | |||
| SAN Primary Storage Qualification ** | RAID Array 4100 | ||
| NOTE: Access to volume (LUN) created by separate HP Fibre Channel Host Bus Adapter and assigned under Selective Storage Presentation and only with a single (non-cascaded) FC-AL Switch 8. | |||
| * Fibre Channel support is a standard feature of the SA-5302/FC and available as an option to other models. Fibre Channel support requires the SAN Access Module. | |||
|
|
|||
| © Copyright 2004 Hewlett-Packard Development
Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |