|
|
Overview
|
HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) |
| HP Modular PDUs have a unique modular architecture designed specifically for data center customers who want to maximize power distribution and space efficiencies in the rack. Modular PDUs consist of two building blocks - the Control Unit (core) and the Extension Bar(s) (sticks). The Control Unit is 1U/0U, and the Extension Bars mount directly to the frame of the rack in multiple locations. Available models range from 16A to 48A current ratings, with output connections ranging from four outlets up to 28 outlets. Single phase and three phase core only units have IEC C-19 outlets on the control unit for BladeSystems as well as larger ProLiant, Integrity and HP9000 servers requiring this type of connection. |
![]() |
| What's New |
|
| |
| Models | ||
| North America, Japan, and South America (Except Argentina and Chile) | ||
| 100 - 127v 1Ø | 2.8 kVA Modular PDU, 24A |
252663-D71
|
| 200 - 240v 1Ø | 3.6 kVA Modular PDU, 16A |
252663-B24
|
| 4.9 kVA Modular PDU, 24A |
252663-D72
|
|
| 8.3 kVA Modular PDU, 40A |
252663-B21
|
|
| 8.3 kVA Modular PDU, 40A |
252663-D73
|
|
| 8.3 kVA Modular PDU, 40A* |
252663-D75
|
|
| 4.9 kVA Modular PDU, 24A* |
252663-D74
|
|
| 200 - 240v 3Ø | 8.6 kVA Modular PDU, 24A 3Ø* |
AF512A
|
| 14.4 kVA Modular PDU, 40A 3Ø* | AF519A | |
| 17.3 kVA Modular PDU, 48A 3Ø* |
AF511A
|
|
| International (Including Argentina and Chile) | ||
| 200 - 240v 1Ø | 3.6 kVA Modular PDU, 16A |
252663-B24
|
| 8.3 kVA Modular PDU, 40A |
252663-B21
|
|
| 7.3 kVA Modular PDU, 32A |
252663-B31
|
|
| 9.2 kVA Modular PDU, 40A |
252663-B32
|
|
| 9.2 kVA Modular PDU, 40A* |
252663-B34
|
|
| 7.3 kVA Modular PDU, 32A* |
252663-B33
|
|
| 380 - 415v 3Ø | 11 kVA Modular PDU, 16A 3Ø* |
AF513A
|
| 22 kVA Modular PDU, 32A 3Ø* |
AF518A
|
|
| * These Modular Distribution Unit Kits are "core only" and do not include any PDU extension bars. | ||
|
|
||
| Related Options | ||
| HP Two C-13 PDU Extension Bars | HP Two C-13 PDU Extension
Bars NOTE: Each extension bar has a C-19 input and 7 C-13 receptacles. The option is ideal for core only models of the modular PDUs |
AF500A |
| HP Two Fixed Cord Extension Bars | HP Two Fixed
Cord Extension Bars NOTE: Each extension bar has a C-19 input and 7 C-13 receptacles on 13 inch cords attached to the extension bars. The option is ideal for powering 1U servers and components. |
351655-B21 |
| Service
and Support Offerings (HP Care Pack Services) | Hardware Installation | U2871A |
| Hardware Installation (Electronic) |
U2871E | |
| | ||
| Feature List |
|
|
|
| Key Features |
|
|
|
Product Highlights
| Unique Modular Design Architecture |
Modular PDUs have unique modular design architecture. This "Building block" concept consists of two main parts, the Control Unit, and the Extension Bar(s). The modular PDUs ship with one Control Unit and up to 4 Extension Bars. The Control Unit is zero-U or 1U rack mountable. Extension Bars mount directly to the rack-frame or the rack extension unit. 1Ø Modular PDUs
3Ø Modular PDUs
NOTE: See model selection matrix below for extension bars which come with each |
|
| |
| Up to 6 PDU Extension Bars |
NOTE: The low voltage extension bars are rated at 1.9kVA, but each C-19 receptacle on the core unit of the 2.8 kVA PDU has a 12A circuit breaker (15A circuit breaker derated to 12A). Therefore the most power an extension bar can draw is 1.4kVA. |
| | |
| Easy Installation | Installation is quick and easy. Whether you choose to mount the Modular PDU in zero-U or 1U, all required mounting brackets, accessories, and installation instructions are shipped with the product. The Extension Bars come with easy to use, snap-in brackets, which fit directly into the rack frame of HP 9000, 10000, and 10000 G2 Series racks. |
| | |
| Compatibility | Ideal for use with the HP 9000, 10000, and 10000 G2 Series Racks, the Modular PDUs are largely designed for the dense rack environment. These Modular PDUs connect directly to the facility input power. |
|
|
Service and Support, HP Care Pack, and Warranty Information
|
Care Pack Services | Care
Pack services provide a range of life cycle support options that let you choose
the service levels that meet your business requirements, from basic to mission-critical.
NOTE:
For more information on HP Care Pack services, contact any of our worldwide
sales offices or resellers or visit our worldwide Web site on the internet at:
http://www.hp.com/hps/carepack |
| | |
| Warranty Upgrade Options | HP Modular PDUs are backed by a limited 3-year
warranty. When used in the HP 9000, 10000, and 10000 G2 Series Racks, HP PDUs assume the warranty of the HP Rack in which they're installed. HP Care Pack services bought for the HP Rack also extend towards the HP Modular PDU if it is being used inside the HP rack. |
|
|
Modular PDU Family Information
| Model Selection Matrix | |||||||
| HP Modular PDUs with Extension Bars |
|
2.8 kVA PDU
|
3.6 kVA PDU
|
4.9 kVA PDU
|
7.3 kVA PDU
|
9.2 kVA PDU
|
8.3 kVA PDU | 9.2 kVA PDU | |
| Part Number |
252663-D71
|
252663-B24
|
252663-D72
|
252663-B31
|
252663-B21
|
252663-D73 | 252663-B32 |
| Input Connection (Single Input) |
NEMA L5-30P
|
Detachable input power cord with an IEC 320-C20 inlet*
|
NEMA L6-30P
|
IEC 309-32A
|
Field Wired Terminal
|
Non-NEMA Locking CS8265C, 50A | IEC-309 63A |
| * The detachable cord can be used only in applications where the total leakage current is less than 3.5 mA. | |||||||
| Output Connections on Modular PDU core |
4 IEC 320 C-19
|
2 IEC 320 C19
|
4 IEC 320 C-19
|
4 IEC 320 C-19
|
4 IEC 320 C-19
|
4 IEC 320 C-19 | 4 IEC 320 C-19 |
| Extension Bars | 4 with 7 NEMA 5-15R* | 2 with 7 IEC 320 C-13 receptacles | 4 with 7 IEC 320 C-13 receptacles | 4 with 7 IEC 320 C-13 receptacles | 4 with 7 IEC 320 C-13 receptacles | 4 with 7 IEC 320 C-13 receptacles | 4 with 7 IEC 320 C-13 receptacles |
| Total Receptacles | 28 NEMA 5-15R | 14 IEC 320 C-13 | 28 IEC 320 C-13 | 28 IEC 320 C-13 | 28 IEC 320 C-13 | 28 IEC 320 C-13 | 28 IEC 320 C-13 |
| * The low volt Extension Bars w/5-15 outlets should be used ONLY with the low volt Control Unit that is shipped with the low volt Modular PDU unit. | |||||||
| Current (max) | 24A | 16A | 24A | 32A | 40A | 40A | 40A |
| AC Voltage Range | 100-127V | 200-240V | 200-240V | 200-240V | 200-240V | 200-240V | 200-240V |
| Frequency (Hertz) | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
| Load Capacity (VA) | 2880 (@120V) | 3680 (@230V) | 4992 (@208V) | 7360 (@230V) | 9200 (@230V) | 8320 (@208V) | 9200 (@230V) |
| Output Circuit Breakers | 4x15A | 2x10A | 4x15A | 4x15A | 4x15A | 4x15A | 4x15A |
| Overload Protection | Yes, per load group | Yes, per load group | Yes, per load group | Yes, per load group | Yes, per load group | Yes, per load group | Yes, per load group |
| Indicator Light on main AC Pilot light on the Control Unit | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Plugs and Cables | |||||||
| Control Unit | Input: 3.6m attached cable with L5-30P | Input: Detachable input power cord (country specific) with a IEC320 C-20 inlet | Input: 3.6m attached cable with L6-30P | Input: 3.6m attached cable with IEC309-32A, Splashproof | Input: Hardwire | Input: Attached Input cord, Non-NEMA Locking CS8265C, 50A | Input: Attached Input cord, IEC-309 63A, Splashproof |
| Facility power connection | NEMA L5-30R
Can also connect directly to the HP R3000 low voltage UPS |
Country specific Can also connect directly to the HP R3000 High Voltage UPS* |
NEMA L6-30R |
IEC60309 2 pole, 3 wire, 200-
240VAC, 32A
IEC 332C6S, 332R6S, or equivalent |
Hard wired to facility power** | Non-NEMA CS8264C or CS8269, 50A or equivalent | IEC60309 2 pole, 3 wire, 200-
240VAC, 63A
IEC 363C6S, 363R6S, or equivalent |
| * For the UPS R3000,
North America high volt model an additional cable option kit, PN 340653-001
(IEC320-C-19 to L6-20P), is needed to connect a 16A mPDU to the NA high
voltage model of the UPS R3000. This cable is also used to connect the PDU
to facility power in North America. ** Hardwiring needs to be done by a certified on-site electrician in accordance with the local electrical installation codes) into the facility input. |
|||||||
| Extension Bars | Input: 2m attached cord with
IEC320-C-20. Output: Each Bar has 8 NEMA 5-15 outlets (12A max per outlet, 12A max per Bar). |
Input: 2m attached cord with
IEC320- C-20. Output: Each Bar has 7 C-13 outlets (10A max per outlet, 16A max per Bar). |
Input: 2m attached cord with
IEC320- C-20. Output: Each Bar has 7 C-13 outlets (10A max per outlet, 16A max per Bar). |
Input: 2m attached cord with
IEC320- C-20. Output: Each Bar has 7 C-13 outlets (10A max per outlet, 16A max per Bar). |
Input: 2m attached cord with
IEC320- C-20. Output: 4 Bars each with 7 C-13 (10A max per outlet, 16A max per Bar); 1 Bar with 4 C-19 (12A max per outlet, 12A max per Bar). |
Input: 2m attached cord with
IEC320- C-20. Output: 4 Bars each with 7 C-13 (10A max per outlet, 16A max per Bar) |
Input: 2m attached cord with
IEC320- C-20. Output: 4 Bars each with 7 C-13 (10A max per outlet, 16A max per Bar) |
| Core Only Modular PDUs |
|
4.9 kVA PDU
|
7.3 kVA PDU
|
8.3 kVA PDU
|
9.2 kVA PDU
|
8.6 kVA PDU
|
11 kVA PDU
|
14.4 kVA |
17.3kVA PDU
|
22 kVA PDU
|
|
| Part Number |
252663-D74
|
252663-B33
|
252663-D75
|
252663-B34
|
AF512A
|
AF513A
|
AF519A |
AF511A
|
AF518A
|
| Input Connection (Single Input) |
Input: 3.6m attached cable with L6-30P
|
Input: 3.6m attached cable with IEC309-32A, Splashproof
|
Input: 3.6m Attached Input cord, Non-NEMA Locking CS8265C,
50A
|
Input: 3.6m Attached Input cord, IEC-309 63A, Splashproof
|
Input: 3.6m Attached input cord, NEMA L15-30P
|
Input: 3.6m Attached Input cord, IEC-309 4 pole, 5 wire,
380-415VAC, 16A, Splashproof
|
Input: 3.6m Attached input cord,
CS8365C plug |
Input 3.6m Attached Input cord IEC-309 3 pole, 4 wire
200-240VAC 60A Waterproof
|
Input: 3.6m Attached Input cord, IEC-309 4 pole, 5 wire,
380-415VAC, 32A, Waterproof
|
| Facility power connection |
NEMA L6-30R
|
IEC60309 2 pole, 3 wire, 200- 240VAC, 32A
IEC 332C6S, 332R6S, or equivalent |
Non-NEMA CS8264C or CS8269, 50A or equivalent
|
IEC60309 2 pole, 3 wire, 200- 240VAC, 63A
IEC 363C6S, 363R6S, or equivalent |
208V 3 phase 3 pole 4 wire (Delta) NEMA L15-30R
|
IEC60309 4 pole, 5 wire, 380-415 VAC, 16A
IEC 516C6S, 516R6S, or equivalent |
208V 3 phase 3 pole 4 wire (Delta) CS8364C, CS8369, or equivalent |
IEC60309 3 pole, 4 wire, 208VAC 60A
IEC 460C9W, 460R9W, or equivalent |
4 pole, 5 wire, 380-415 VAC, 32A
IEC 532C6W, 532R6W, or equivalent |
| Output Connections on Modular PDU core |
4 IEC 320 C-19
|
4 IEC 320 C-19
|
4 IEC 320 C-19
|
4 IEC 320 C-19
|
6 IEC 320 C-19
|
6 IEC 320 C-19
|
6 IEC 320 C-19 |
6 IEC 320 C-19
|
6 IEC 320 C-19
|
| Extension Bars |
None
|
None
|
None
|
None
|
None
|
None
|
None |
None
|
None
|
| Total Receptacles |
4 IEC 320 C-19
|
4 IEC 320 C-19
|
4 IEC 320 C-19
|
4 IEC 320 C-19
|
6 IEC 320 C-19
|
6 IEC 320 C-19
|
6 IEC 320 C-19 |
6 IEC 320 C-19
|
6 IEC 320 C-19
|
| Current (max) |
24A
|
32A
|
40A
|
40A
|
41.52A, 13.84A/phase
|
16A
|
69A, 23A/phase |
83.04A
27.68/phase |
32A phase
|
| AC Voltage Range |
200-240V
|
200-240V
|
200-240V
|
200-240V
|
208v 3Ø Delta
|
380-415v 3Ø Wye
|
208v 3Ø Delta |
208v 3Ø Delta
|
380-415v 3Ø Wye
|
| Frequency (Hertz) |
50/60Hz
|
50/60Hz
|
50/60Hz
|
50/60Hz
|
50/60Hz
|
50/60Hz
|
50/60Hz |
50/60Hz
|
50/60Hz
|
| Load Capacity (VA) |
4992 (@208V)
|
7360 (@230V)
|
8320 (@208V)
|
9200 (@230V)
|
8600 (@208V)
|
11000 (@230v)
|
14393 (@208V) |
17300 (@208V)
|
22000
(@230V) |
| Output Circuit Breakers |
4x15A
|
2x10A
|
4x15A
|
4x15A
|
6 X 20A
|
6 X 16A
|
6 X 20A |
6 X 20A
|
6 X 16A
|
| Overload Protection |
Yes, per load group
|
Yes, per load group
|
Yes, per load group
|
Yes, per load group
|
Yes, per load group
|
Yes, per load group
|
Yes, per load group |
Yes, per load group
|
Yes, per load group
|
| HP Power Cables | Cable | Description |
Part Number
|
| IEC C-13 |
4.5 ft (1.37 m), x15 |
10A, IEC320 C-14 to IEC 320 C-13 cables for connecting devices to the power distribution unit. |
142257-007
|
| 4.5 ft (1.37 m), x1 |
142257-006
|
||
| 1.6 ft (0.5m) x1 |
142257-B28
|
||
| 8 ft (2.5m) x1 |
142257-002
|
||
| 6 ft (1.83m) x1 | 10A, IEC320 C-14 to NEMA -15 cables for connecting devices to the low voltage power distribution unit |
AF556A
|
|
| IEC C-19 | 8 ft (2.5m) x 1 |
16A, IEC C-19 to IEC C-20 for connecting
16A mPDU to R3000 High voltage UPS, international model |
295633-B22
|
| 12 ft (3.66m) x1 | 16A, IEC C-19 to NEMA L6-20 for connecting 16A mPDU directly to a facility outlet or R3000 high voltage UPS in North America/Japan |
AF593A
|
|
| Please refer to the Power Cord
Matrix for more information on power cords/cable part numbers, input/output
descriptions. http://www.hp.com/go/powercordmatrix. |
|||
| Disclaimer: HP makes no recommendations regarding power connector manufactures. The model numbers listed in the above tables are strictly for the purpose of providing examples. Please consult a licensed professional to determine the best connector or receptacle for your specific needs. | |||
|
|
Technical Specifications
| All PDUs | |
| Shipping Weight | 20.2 lb (9.16 kg) |
| Operating Temperature | 50° to 122° F (10° to 50° C) |
| Operating Relative Humidity (%) | 10% to 90% |
| Operating Elevation | 0 to 10,000 ft (0 to 3048 m) |
| Storage Temperature | -4° to 140° F (-20° to 60° C) |
| Storage Relative Humidity (%) | 5% to 95% |
| Storage Elevation | 0 to 30,000 ft (0 to 9144 m) |
| Input Plug Length | 142 inches (360.7 cm) |
| Conformance Standards | UL, CUL, CE, NOM, D - 16A and
40A models UL, CUL, NOM - 24A High and Low voltage models CE, D - 32A model |
| 1Ø 2.8kVA to 9.2kVA | |
| Mechanical Dimensions (WxHxD) | 17.5 x 1.62 x 5.6 in (44.45 x 4.11 x 14.22 cm) |
| Unit Weight | 18 lb (8.16 kg) |
| Shipping Dimensions (WxHxD) | 21.5 x 12.25 x 13.0 in (54.61 x 31.12 x 33.02 cm) |
| 3Ø 8.6 kVA to 22 kVA | |
| Mechanical Dimensions (WxHxD) | 17.5 x 1.62 x 7.5 in (44.45 x 4.11 x 19.22 cm) |
| Unit Weight | 20 lb (9.07 kg) |
| Shipping Dimensions (WxHxD) | 21.5 x 12.25 x 15.0 in (54.61 x 31.12 x 38.1 cm) |
| Shipping Weight | 22.2 lb (10.07 kg) |
| Kit Contents | |
| All Modular PDUs | All models ship with: 0U/1U Mounting brackets/hardware for Control Unit Cord Retention bracket for the Control Unit Tie wraps Install Card |
| Sku Specific Kit Contents | |
| 252663-D71 | 2.8kVA ship with 1.x Control Unit and 4 x NEMA 5-15P Extension Bars |
| 252663-B34 | 3.6kVA,16A Modular PDU ship with 1 x Control Unit and 2 x Extension Bars, and country specific power cord, Mounting brackets for Extension Bars |
| 252663-B21 | 9.2kVA, "field wire" Modular PDU ship with 1 x Control Units, 4 x C-13 Extension Bars, Mounting brackets for Extension Bars |
| 252663-D72, 252663-D73, 252663-B31, 252663-B32 | ship with 1 x Control Unit and 4 x C-13 Extension Bars, Mounting brackets for Extension Bars |
| 252663-B33, 252663-B34, 252663-D74, 252663-D75, AF512A, AF513A, AF511A, AF518A, and AF519A | ship with 1 x Control Unit |
|
|
|
|
Environment-friendly Products and Approach | End-of-life Management and Recycling | Hewlett-Packard
offers end-of-life HP product return, trade-in, and recycling programs in many
geographic areas. For trade-in information, please go to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will be recycled,
recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
| | ||
|
© Copyright 2008 Hewlett-Packard Development Company, L.P. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |