Overview
|
HP ProLiant BL10e e-Class Server Blade
|
|||
|
ProLiant BL e-Class Server Blade Enclosure
(shown with 20 ProLiant BL10e server blades) |
|
|
![]() |
|
ProLiant BL10e Server Blade
|
What's New
|
![]() |
|
PLUS
|
![]() |
|
PLUS
|
|
|
||||
![]() |
or
|
![]() |
or
|
![]() |
|
a. C-GbE Interconnect Switch
|
b. RJ-45 Patch Panel
|
c. RJ-21 Patch Panel
|
||
| Configuration Steps For a complete configuration of the HP ProLiant BL e-Class system, do the following:
|
|
|
Standard Features
| HP ProLiant BL10e Server Blade | |
| Processor |
One Ultra-Low Voltage Intel Pentium III 900-MHz processor; 100-MHz front-side bus |
|
|
|
| Cache
Memory |
512K Level-2 on-die Cache | |
|
|
||
| Chipset |
ServerWorks LELP
3.0 chipset NOTE: For more information regarding ServerWorks, please see the following URL: http://www.serverworks.com/products/overview.html. | |
| | ||
| Memory |
Standard | 512-MB PC133-MHz Registered ECC SDRAM DIMM Memory (1x512 MB) | |
| Maximum | 1024 MB (2 DIMM slots total) | ||
|
|
|||
| Network
Controller |
Two Compaq NC3163 Fast Ethernet NICs Embedded 10/100 WOL (Wake On LAN) enabled with PXE | |
|
|
||
| Internal
Storage |
Hard Drive | One 40-GB Ultra ATA/100 5,400 rpm Non-Hot Plug 2.5" hard drive | |
|
|
|||
| Warranty |
1 year on parts, 9x5 NBD. Care Pack warranty upgrades available to add labor, on-site service, faster response times, and longer terms to the standard server blade warranty. PXE | |
|
|
||
| Form
Factor |
Server blades plug vertically into HP ProLiant BL e-Class Server Blade Enclosure | |
|
|
||
| Product
Demo |
To view
the Product Demo, please see the following URL, then click on "PRODUCT DEMO": http://www5.compaq.com/products/servers/proliant-bl/e-class/index.html. | |
| | ||
| HP ProLiant BL10e Server Blade | |
| HP ProLiant BL e-Class Server Blade Enclosure | 5.25 inch Height (3U), 17.5
inch Width, 28.35 inch Depth Bays for up to 20 ProLiant BL10e server blades |
|
|
|
| Rack Capability | Mounts in HP, Compaq-branded, third-party, and Telco racks. Rack mounting hardware for HP, Compaq-branded and third-party racks ships standard with each server blade enclosure. Telco rack-mounting hardware is a separately available option kit. | |
|
|
||
| Server Blade Enclosure includes | Rear bay for 1 of 3 Interconnect
Tray configurations for network cable management (see below). Two (2) Diagnostic Adapters for connecting keyboard, video, mouse and other devices locally to individual server blades ProLiant Essentials Foundation Pack for ProLiant BL Servers, includes the Insight Manager 7 and Management Agents CD and ProLiant Essentials Rapid Deployment Pack CD (trial version 7-days, 10 nodes). (NOTE: The ProLiant BL e-Class server blade enclosure can also be purchased bundled with 20 licenses for Rapid Deployment Pack at 50% of the standard license price.) Four (2+ 2 redundant) hot- plug fans Dual (1+ 1 redundant) hot- plug power supplies (600 watts each), power cords Server blade blanks (to fill 19 of the 20 server blade bays) Rack mounting hardware for HP, Compaq-branded and third-party racks Null-modem cable for serial connection to the Integrated Administrator serial "Console" connector HP Documentation CD |
|
|
|
||
| Warranty | 3 years on parts, labor and on-site service. Care Pack warranty upgrades available to add faster response times to the standard warranty. | |
|
|
||
| HP ProLiant BL e-Class Interconnect Trays | |
| NOTE: Each interconnect tray includes the Integrated Administrator module. | |
| Please see the following (3)
interconnect tray configurations for accessing server blade network connections: ProLiant BL e-Class C-GbE Interconnect Switch (with 4 Gigabit Ethernet uplinks for up to 40-to-1 network cable reduction!) NOTE: See details below. RJ-45 Patch Panel (with 40 RJ-45 connectors) RJ-21 Patch Panel (with 4 RJ-21 connectors for cable aggregation behind the enclosure) NOTE: See "Other Options" below for RJ-21 to RJ-45 Cable option kit. |
|
| Warranty | 3 years on parts, labor and on-site service. Care Pack warranty upgrades available to add faster response times to the standard warranty. |
|
|
|
| HP ProLiant BL e-Class Integrated Administrator Features |
http://www.compaq.com/products/servers/proliant-bl/e-class/integrated-admin.html. |
| |
| HP ProLiant BL e-Class C-GbE Interconnect Switch Features |
For more information on the ProLiant BL e-Class C-GbE Interconnect
Switch, please visit the Web site at: |
|
|
| Other Options |
|
|
|
| Diagnostic Adapter Interfaces | |
| NOTE: Two Diagnostic Adapters are included with every ProLiant BL e-Class Server Blade Enclosure. | |
|
ProLiant BL10e server blade LEDs and buttons
NOTE: The TEAC USB CD ROM Drive must be purchased directly from TEAC or a TEAC reseller. | |
| | |
| ProLiant Essentials Foundation Pack Software for the ProLiant BL Server |
|
||
|
|||
|
|||
|
|||
|
|||
|
|||
| NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials | |||
|
|
|||
| Optional ProLiant Essentials Value Packs | Optional software offerings
that selectively extend the functionality of an Adaptive Infrastructure
to address specific business problems and needs:
|
|
|
|
| SmartStart | SmartStart is a tool that simplifies
single server setup, providing a rapid way to deploy reliable and consistent
server configurations. SmartStart 7.00 and later can now deploy the ProLiant
BL20P G3 and ProLiant BL40P servers, using the I/O port with an attached
USB CD-ROM device. To obtain a copy of SmartStart for your blade server,
redeem the coupon that is included with your Blade server or order your
copy from the SmartStart web site. For more information, please visit the
SmartStart Web site at http://www.hp.com/servers/smartstart. SmartStart version supported (minimum): SmartStart 6.20 |
|
|
|
| Industry Standard Compliance | ACPI 1.0b compliant SDG 3.0 compliant Microsoft Logocertifications MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface MIB (RFC 2233), 801.1Q MIB (RFC 2684), RMON1 MIB (RFC 1757) groups 1, 2, 3, and 9, and Ethernet MIB (RFC1643) (ProLiant BL e-Class C-GbE Interconnect Switch interconnect tray option) IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.1D, IEEE 802.1p, IEEE 802.3ac and 802.1Q, IEEE 802.1Q, and IEEE 802.3x (ProLiant BL e-Class C-GbE Interconnect Switch interconnect tray option) SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9 (ProLiant BL e-Class C-GbE Interconnect Switch interconnect tray option) |
|
|
|
| Intelligent Manageability | Insight Manager 7 HP Systems Insight Manager ROM Based Setup Utility (RBSU) Automatic Server Recovery (ASR-2) Enclosure Self Recovery (ESR) Advanced Configuration and Power Interface Specification Ready (ACPI) Server Blade and Enclosure Health Logs Redundant Power Supply Utility Power Down Utility Pre-Failure Warranty (covers processors, hard drives and memory) HP Interconnect Switch Management System and Utilities (included with the ProLiant BL e-Class C-GbE Interconnect Switch interconnect tray option) |
|
|
|
| Availability | Redundant Hot-Plug Power Supplies
(ProLiant BL e-Class Server Blade Enclosure) Redundant Hot-Plug Fans (ProLiant BL e-Class Server Blade Enclosure) ECC Memory (ProLiant BL10e Server Blade) Redundant ROM (ProLiant BL10e Server Blade) Dual network communication paths to each server blade using redundant, non-blocking layer 2 switch modules with redundant inter-module communication links (ProLiant BL e-Class C-GbE Interconnect Switch interconnect tray option Two redundant uplink ports per each interconnect switch module (ProLiant BL e-Class C-GbE Interconnect Switch interconnect tray option Spanning tree protocol for loop-free path redundancy (ProLiant BL e-Class C-GbE Interconnect Switch interconnect tray option |
|
|
|
| Security | Power-on password Administrator's password Secure Shell (SSH) access through the Integrated Administrator serial console Multilevel user names and passwords with configurable time out period setting, up to 64 IEEE 802.1Q tagged VLANs per interconnect switch module, and IP address restriction (ProLiant BL e-Class C-GbE Interconnect Switch interconnect tray option |
|
|
|
| OS Support | Microsoft® Windows
2000 Server RedHat Linux SuSE Linux Microsoft Windows Server 2003 (when available) NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS Support Matrix at: http://www.hp.com/go/supportos NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux Web site at http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html. |
| | |
| Rack Airflow Requirements |
Rack 10000 series Cabinets
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. NOTE: Please consult the Setup & Installation Guide for the server for additional details. |
|
|
|
| Service and Support |
Three-year limited warranty, including hardware diagnostic support, pre-failure
warranty (coverage of hard drives, memory and processors). The warranty
is fully supported by HP Services and a worldwide network of resellers
and service providers. In addition 90-day's getting started software telephone
support may be covered under the warranty or available for an additional
fee. Enhancements to warranty services are available through HP Care Pack
services. Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware and software services are available including:
HP Care Pack services for ProLiant BL p-Class server blades, cover the server blade and the p-Class blade enclosure that the server blade is installed in as well as interconnects, power enclosure with power supplies and power distribution. |
| NOTE:
For more information on HP Care Pack services, contact any of our worldwide
sales offices or resellers or visit our worldwide Web site on the internet
at: http://www.hp.com/hps/carepack NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at: http://www.hp.com/hps NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html |
|
|
Models
| ProLiant BL10e P900-512KB (ULV), 512-MB, 40-GB ATA | Processor | One Ultra-Low Voltage Intel Pentium III 900-MHz processor; 100-MHz front-side bus |
| Cache Memory | 512-KB Level-2 on-die cache | |
| 311538-B21 (1 pack) 311539-B21 (10 pack) |
Memory | 512 MB (Standard) to 1024 MB (Maximum) PC133-MHz Registered ECC SDRAM DIMM Memory (1x512 MB) |
| Network Controller | Two Compaq NC3163 Fast Ethernet NICs Embedded 10/100 WOL (Wake On LAN) enabled with PXE | |
| Hard Drive | One 40-GB Ultra ATA/100 5,400 rpm Non-Hot Plug 2.5² hard drive | |
| Form Factor | Plugs vertically into HP ProLiant BL e-Class Server Blade Enclosure |
|
|
Options
| ProLiant BLe-Class Unique Options | Four (4) RJ-21
to RJ-45 cables for use with the RJ-21 Patch Panel interconnect tray (10 foot cables) |
257076-B21
|
|
| Enclosure Shipping
Bracket Kit NOTE: When shipping an enclosure in a rack shipping brackets must be installed to the rack. |
293119-B21
|
||
|
|
|||
| Server Blade Enclosure | ProLiant BL e-Class Server Blade Enclosure |
243280-B21
|
|
| ProLiant BL e-Class Server Blade Enclosure (includes 20 licenses for ProLiant Essentials Rapid Deployment Pack at 50% of the standard per-node license list price) |
273644-B21
|
||
|
|
|||
| Interconnect Trays (each includes an Integrated Administrator module) | Interconnect Tray, ProLiant BL e-Class C-GbE Interconnect Switch |
243283-B21
|
|
| Interconnect Tray, RJ-21 Patch Panel |
253177-B21
|
||
| Interconnect Tray, RJ-45 Patch Panel |
243282-B21
|
||
|
|
|||
| ProLiant
Essentials Value Pack Software |
ProLiant Essentials
Rapid Deployment Pack (1 node license, V1.1) NOTE: Each server blade bay slot populated by a server blade requires one license. |
267196-B21
|
|
| ProLiant Essentials Rapid Deployment Pack (10 node license, V1.1) |
269817-B21
|
||
| ProLiant Essentials Workload Management Pack (Featuring Resource Partitioning Manager version 2.0) |
303284-B21
|
||
| NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.compaq.com/proliantessentials. | |||
| ProLiant Essentials
Intelligent Networking Pack, Single Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372906-B21
|
||
| ProLiant Essentials
Intelligent Networking Pack, Flexible License NOTE: For use with multiple servers. This part number can be used to purchase multiple licenses with a single activation key. The quantity ordered for this part number will be the quantity of licenses included in the kit in the form of a corresponding activation key. Use the same key to activate all licenses in the actual quantity ordered. For a given order, one kit will be delivered with the activation key, and documentation. |
372950-B21
|
||
| ProLiant Essentials
Intelligent Networking Pack, Tracking License NOTE: For use with signed and implemented Activation Key Agreements only. Purchase of this part number entitles the customer to deploy additional licenses of the product under the terms of the existing Activation Key Agreement. NOTE: Nothing is delivered in conjunction with the purchase of this part number. Visit http://h18004.www1.hp.com/products/servers/proliantessentials/license/akalic.html for more information on Activation Key Agreements. |
372951-B21
|
||
|
|
|||
|
Memory (SDRAM DIMMs) |
512-MB PC 133-MHz Registered ECC SDRAM DIMM Memory Option Kit (1 x 512 MB) |
128279-B21
|
| 256-MB PC 133-MHz Registered ECC SDRAM DIMM Memory Option Kit (1 x 256 MB) |
128278-B21
|
|
| 128-MB PC 133-MHz Registered ECC SDRAM DIMM Memory Option Kit (1 x 128 MB) |
128277-B21
|
|
|
|
||
| UPS and PDU Power Cord Matrix | Please
see the UPS and PDU cable matrix that lists cable descriptions, requirements,
and specifications for UPS and PDU units: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf. | |
| | ||
| Uninterruptible Power Systems- Rack | Compaq UPS R1500 XR (1440VA, 1340 Watt), Low Voltage (NA) |
204404-001
|
| Compaq UPS R1500 XR (1500VA, 1340 Watt), High Voltage (Int'l) |
204404-B31
|
|
| Compaq UPS R1500 XR (1500VA, 1340 Watt), Low Voltage (Japan) |
204404-291
|
|
| Compaq UPS R3000 XR (2880VA, 2700 Watt), Low Voltage (NA) |
192186-001
|
|
| Compaq UPS R3000 XR (3000VA, 2700 Watt), High Voltage (NA) |
192186-002
|
|
| Compaq UPS R3000 XR (2400VA, 2250 Watt), Low Voltage (Japan) |
192186-291
|
|
| Compaq UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Japan) |
192186-292
|
|
| Compaq UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Int'l detachable cord) |
192186-B31
|
|
| Compaq UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A IEC309 Plug) |
192186-B32
|
|
| Compaq UPS R3000 XR (3000VA, 2700
Watt), High Voltage (16A CEE 7/7 SCHUKO Plug) |
192186-B33
|
|
| Compaq UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A BS-546 Plug) |
192186-AR1
|
|
| Rack-Mountable UPS R6000 (6000VA,
6000 Watt) High Voltage (NA) NOTE: The UPS R6000 has a hardwired input. |
347207-001
|
|
| Rack-Mountable UPS R6000 (6000VA,
6000 Watt) High Voltage (Int'l) NOTE: The UPS R6000 has a hardwired input. |
347207-B31
|
|
| Rack-Mountable UPS R6000 (6000VA,
6000 Watt) High Voltage (Japan) NOTE: The UPS R6000 has a hardwired input. |
347207-291
|
|
| UPS R12000 XR N+ x (200-240V)
(WW-hardwired) NOTE: The UPS R12000 XR has a hardwired input and output. |
207552-B22
|
|
|
|
||
| UPS Options | SNMP Serial Port Card NOTE: Supports tower and rack UPS XR models ranging from 1000 3000VA. |
192189-B21
|
| Six Port Card NOTE: Supports tower and rack UPS XR models ranging from 1000 3000VA. |
192185-B21
|
|
| Extended Runtime Module, R1500
XR NOTE: 2U each, two ERM maximum. |
218971-B21
|
|
| Extended Runtime Module, R3000
XR NOTE: 2U each, one ERM maximum. |
192188-B21
|
|
| Extended Runtime Module, R6000 NOTE: 3U each, two ERM maximum. |
347224-B21
|
|
| Extended Runtime Module, R12000
XR, 4U NOTE: 4U each, two ERM maximum. |
217800-B21
|
|
| R12000 XR BackPlate Receptacle
Kit, (2) L6-30R (NA) NOTE: The R12000 XR BackPlate Kit has a hardwired input. |
325361-001
|
|
| R12000 XR BackPlate Receptacle
Kit, (2) IEC-309R (WW) NOTE: The R12000 XR BackPlate Kit has a hardwired input. |
325361-B21
|
|
| SNMP-EN Adapter NOTE: Supports R6000 UPS series only. |
347225-B21
|
|
|
|
||
| Rack-Mountable PDUs
1U/0U (Up to 12 outlets) NOTE: 0U mounting brackets shipped with the unit (separate option kit for 1U mounting). |
Compaq Power Distribution Unit-16A
(200 to 240V) (WW) NOTE: The 16A PDU also connects to the high volt models of the UPS R3000 XR (need cable PN 340653-001 (NA)) and the UPS R6000 models. Cable PN 340653-001 required if connecting to UPS R3000 XR (192186-002 NA-High Volt model only). |
207590-B21 |
| Compaq Power Distribution Unit-32A (200 to 240V) (Int'l) |
207590-B31
|
|
| Compaq Power Distribution Unit-40A (200 to 240V) (WW) |
207590-B23
|
|
| NOTE:
Please see the following Power Distribution Unit (Zero-U/1U PDU) QuickSpecs
for additional options, including cables: http://h18000.www1.hp.com/products/quickspecs/10838_na/10838_na.HTML (North America) http://h18000.www1.hp.com/products/quickspecs/10838_div/10838_div.HTML (Worldwide) |
||
|
|
||
| Modular
PDUs 1U/0U (Up to 32 outlets) NOTE: 1U/0U mounting brackets shipped with the unit (optimized for 10000 and 9000 series racks). |
Modular Power Distribution Units
(mPDU), High Volt Model, 16A (200-240 VAC) (WW) NOTE:This model has a detachable input power cord and is adaptable to country specific requirements. The 16A PDU also connects to the high volt models of the UPS R3000 XR and R6000 models. Cable P/N 340653-001 required if connecting to UPS R3000 XR (192186-002 NA High Volt model only). |
252663-B24
|
| Modular Power Distribution Units
(mPDU), Low Volt Model, 24A (100-127 VAC) (NA, Japan) NOTE:This mPDU (252663-D71) may also be used to connect the low volt model of the UPS R3000 XR. |
252663-D71
|
|
| Modular Power Distribution Units
(mPDU), High Volt Model, 24A (200-240 VAC) (NA, Japan) |
252663-D72
|
|
| Modular Power Distribution Units (mPDU), High Volt Model, 32A (200-240 VAC) (Int'l) |
252663-B31
|
|
| Modular Power Distribution Units
(mPDU), High Volt Model, 40A (200-240 VAC) (WW) NOTE:This mPDU (252663-B21), 40A model has a hardwired input. |
252663-B21
|
|
| NOTE:
Please see the following Modular Power Distribution Unit (Zero-U/1U
Modular PDUs) QuickSpecs for additional options including shorter jumper
cables and country specific power cords: http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.HTML (North America) http://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.HTML (Worldwide) |
||
|
|
||
| USB Options | USB Optical Scroll Mouse (Carbonite) | DD441B |
| USB 1.44-MB External Diskette Drive (Carbonite) |
DC141B
|
|
| TEAC USB CD-ROM |
TEAC CD-210
|
|
| NOTE: The TEAC USB CD ROM Drive must be purchased directly from TEAC or a TEAC reseller. | ||
| USB Easy Access Keyboard (Carbonite/Silver) |
DC168B#
|
| USB Easy Access Keyboard (Carbonite) Country Key Code | ||||
| Dash # | Description | Dash # | Description | |
| A2M | ICELAND | ABT | HE | |
| AB0 | TAWA | ABU | UK | |
| AB1 | KOR | ABV | ARA | |
| AB2 | PRC | ABX | FIN | |
| AB6 | FRA | ABY | DEN | |
| AB7 | GRK | ABZ | ITL | |
| AB8 | TURK | AC0 | BEL | |
| AB9 | PORT | AC4 | BRZ | |
| ABA | US | ACB | RUSS | |
| ABB | EURO | AKB | CZE | |
| ABC | FCAN | AKC | HUNG | |
| ABD | GR | AKD | POL | |
| ABE | SP | AKL | THAI | |
| ABF | FR | AKN | BHCSY | |
| ABH | NL | AKR | SLOV | |
| ABJ | Japan | ARK | ICELAND | |
| ABM | LA | B15 | KAZ | |
| ABN | NOR | UUZ | SWISS | |
| ABS | SW | |||
|
|
||||
| Tape Libraries | HP StorageWorks ESL9000 Series
Tape Libraries |
|
| ESL9595 Extended Tape Library,
0 drive, 400 slots (card cage, Interface Mgr card, Command View license) |
343378-B21 | |
| ESL9595 Library, 0 drive, 400
slots |
330833-B21 | |
| ESL9322 Extended Tape Library,
0 drive, 222 slots (card cage, Interface Mgr card, Command View license) |
343377-B21 | |
| ESL9595 Library, 0 drive, 222
slots |
330832-B21 | |
| ESL9000 Ultrium 460 drive kit |
330834-B21 | |
| ESL9000 Ultrium 230 drive kit |
301930-B21 | |
| ESL9000 SDLT 320 drive kit |
293414-B21 | |
| ESL9000 400 to 500 slot upgrade | 330842-B21 | |
| ESL9000 500 to 595 slot upgrade |
330842-B22 | |
| ESL9000 400 to 595 slot upgrade |
330842-B23 | |
| ESL9000 222 to 322 slot upgrade |
330840-B21 | |
| ESL9000 E2400-160 FC Interface
Controller (one controller for every four drives) |
330839-B21 | |
| License for Direct Backup Engine
ESL |
343375-B21 | |
| License for Secure Manager ESL |
343376-B21 | |
| NOTE: Please reference the ESL9000 Series Tape Libraries QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs | ||
|
|
||
| Custom Builder | Please see the Enterprise Configurator for configuration assistance at: http://www.hp.com/products/configurator. |
| | |
|
HP Rack 10000 Series (Graphite Metallic) | S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22 |
| HP Rack 10647 (47U) Pallet | 245160-B21 | |
| HP Rack 10647 (47U) Crated | 245160-B23 | |
| HP Rack 10642 (42U) Pallet | 245161-B21 | |
| HP Rack 10642 (42U) Shock Pallet | 245161-B22 | |
| HP Rack 10642 (42U) Crated | 245161-B23 | |
| HP Rack 10636 (36U) Pallet | 245162-B21 | |
| HP Rack 10636 (36U) Shock Pallet | 245162-B22 | |
| HP Rack 10636 (36U) Crated | 245162-B23 | |
| HP Rack 10622 (22U) Pallet | 245163-B21 | |
| HP Rack 10622 (22U) Shock Pallet | 245163-B22 | |
| HP Rack 10622 (22U) Crated | 245163-B23 | |
| NOTE:
-B21 (pallet) used to ship empty racks shipped on a truck -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels) -B23 (crated) used for air shipments of empty racks NOTE: Not all HP equipment is qualified to be shipped in the Rack 10000 series. |
||
| NOTE:
Please see the Rack 10000 QuickSpecs for Technical Specifications such as
height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.HTML (Worldwide) http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.HTML (North America) NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/racks/index.html. |
||
| | ||
| Rack Options for
HP Rack 10000 Series |
HP Light kit for 10000 series rack | 361589-B21 | |||||||||||||||||||||||||||
| HP Plinth kit for 10000 series rack | 251960-B21 | ||||||||||||||||||||||||||||
| 800mm Wide Stabilizer Kit (Graphite) | 255488-B21 | ||||||||||||||||||||||||||||
| NOTE: Supported by the Rack 10842 cabinet only. | |||||||||||||||||||||||||||||
| 600mm Stabilizer Kit Graphite | 246107-B21 | ||||||||||||||||||||||||||||
| Baying Kit for Rack 10000 series (Carbon) | 248929-B21 | ||||||||||||||||||||||||||||
| 42U Side Panel Graphite Metallic | 246099-B21 | ||||||||||||||||||||||||||||
| 110V Fan Kit (Graphite) | 257413-B21 | ||||||||||||||||||||||||||||
| NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 5-15P. | |||||||||||||||||||||||||||||
| 220V Fan Kit (Graphite) | 257414-B21 | ||||||||||||||||||||||||||||
| NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 6-15P. | |||||||||||||||||||||||||||||
| 36U Side Panel Graphite Metallic | 246102-B21 | ||||||||||||||||||||||||||||
| 47U Side Panel Graphite Metallic | 255486-B21 | ||||||||||||||||||||||||||||
| 9000/10000 Series Offset Baying Kit (42U) | 248931-B21 | ||||||||||||||||||||||||||||
| NOTE: This kit can be used to connect 9000 and 10000 series racks of the same U height together. Kit contents include hardware for connecting racks and a panel to cover the 100mm gap at the rear of the two racks. | |||||||||||||||||||||||||||||
| NOTE: For additional information regarding Rack Options, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. | |||||||||||||||||||||||||||||
| Ballast Option Kit |
120672-B21
|
||||||||||||||||||||||||||||
| 9000/10000 Series Offset Baying Kit (42U) |
248931-B21
|
||||||||||||||||||||||||||||
| NOTE: This kit can be used to connect 9000 and 10000 series racks of the same U height together. Kit contents include hardware for connecting racks and a panel to cover the 100mm gap at the rear of the two racks. | |||||||||||||||||||||||||||||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html | |||||||||||||||||||||||||||||
| Rack Rail Adapter Kit (25" depth) | 120675-B21 | ||||||||||||||||||||||||||||
| 100 kg Sliding Shelf | 234672-B21 | ||||||||||||||||||||||||||||
| Monitor/Utility Shelf - Graphite | 253449-B21 | ||||||||||||||||||||||||||||
| Depth Adjustable Fixed Rail | 332558-B21 | ||||||||||||||||||||||||||||
| Cable Management D-Rings Kit | 168233-B21 | ||||||||||||||||||||||||||||
| Server Console Switch 1 x 4 port (100-230 VAC) | 400336-001 | ||||||||||||||||||||||||||||
| Server Console Switch 1 x 4 port (100-230 VAC) (Intl) | 400336-B31 | ||||||||||||||||||||||||||||
| Server Console Switch 1 x 4 port (100-230 VAC) (Japan) | 400336-291 | ||||||||||||||||||||||||||||
| IP Console Switch Box, 1 x 1 x 16 | 262585-B21 | ||||||||||||||||||||||||||||
| IP Console Switch Box, 3 x 1 x 16 | 262586-B21 | ||||||||||||||||||||||||||||
| CPU to Server Console Cable, 12 | 110936-B21 | ||||||||||||||||||||||||||||
| CPU to Server Console Cable, 3 | 110936-B24 | ||||||||||||||||||||||||||||
| CPU to Server Console Cable, 7 | 110936-B25 | ||||||||||||||||||||||||||||
| IP CAT5 Cable 3, 4 pack | 263474-B21 | ||||||||||||||||||||||||||||
| IP CAT5 Cable 6, 8 pack | 263474-B22 | ||||||||||||||||||||||||||||
| IP CAT5 Cable 12, 8 pack | 263474-B23 | ||||||||||||||||||||||||||||
| IP CAT5 Cable 20, 4 pack | 263474-B24 | ||||||||||||||||||||||||||||
| IP CAT5 Cable 40, 1 pack | 263474-B25 | ||||||||||||||||||||||||||||
|
Switch Box Connector Kit (high voltage) (Int'l) |
144007-B33 | ||||||||||||||||||||||||||||
| TFT5600 Rack Keyboard Monitor | 221546-xx1 | ||||||||||||||||||||||||||||
| TFT7210R Rack Mounted 17" Monitor | 348373-B21 | ||||||||||||||||||||||||||||
| NOTE:
For a complete list of Monitors please view the following URL: http://h18004.www1.hp.com/products/monitors/ |
|||||||||||||||||||||||||||||
| 1U Rack Keyboard & Drawer (Carbon) |
257054-xx1
|
||||||||||||||||||||||||||||
| Country Code Key(for 1U Rack Keyboard & Drawer (PN 257054-xx1)) | |||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
| NOTE: For additional information regarding Rack Options, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. | |||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||
| Rack Options for HP, Compaq-branded, Third Party and Telco racks | Telco rack-mounting hardware kit for ProLiant BL e-Class Server Blade Enclosure |
266076-B21
|
| Enclosure Shipping Bracket Kit NOTE: When shipping an enclosure in a rack shipping brackets must be installed to the rack. |
293119-B21
|
|
|
|
||
| Service and Support Offerings (HP Care Pack Services) |
|
|
|
Memory
| ProLiant BL10e Server Blade |
|
Standard Memory 512-MB PC 133-MHz Registered ECC SDRAM DIMM installed (1 x 512-MB SDRAM DIMM) Standard Memory Plus Optional Memory Up to 1024 MB of SDRAM DIMM memory is available with the installation of optional SDRAM DIMM memory expansion kits. |
|
Memory
|
Slot
|
||
|
|
1
|
2
|
|
|
Standard
|
512 MB
|
512 MB
|
Empty
|
|
Optional
|
640 MB
|
512 MB
|
128 MB
|
|
Optional
|
768 MB
|
512 MB
|
256 MB
|
|
Maximum
|
1024 MB
|
512 MB
|
512 MB
|
| Following are memory options available from HP: | |
|
128279-B21 |
|
128278-B21 |
|
128277-B21 |
|
|
Technical Specifications
| HP ProLiant BL p-Class Server Blade Enclosure | Dimensions | Height | 5.25 in (13.35 cm) (3U) |
| Width | 17.5 in (44.45 cm) | ||
| Depth | 28.35 in (72.01 cm) | ||
| Weight | Interconnect Tray | 4.5 lb (2.04 kg) | |
| 20 server blades | 35 lb (15.86 kg) | ||
| Enclosure with 2 power supplies | 54.5 lb (24.7 kg) | ||
| Total weight fully loaded | 94 lb (41.73 kg) | ||
| | |||
| Power Supply | 600W,
Hot-Plug Redundant (2 standard) | Two Redundant Power Supplies (optimized to provide full redundancy at 120 and 220 volts) | |
| Input Specifications | Normal Line Voltage | 100 to 127VAC, 200 to 240VAC | |
| Range Input Line | 90 to 264VAC | ||
| Frequency Range | 43 to 63Hz | ||
| Power Factor | > 0.95 (120Vac/Max Load) | ||
| Input Current | 8.5A @ 120VAC, 4.3A @ 240VAC | ||
| Inrush Current | 25A | ||
| Holdup Time | 25mS | ||
| General Specifications | Full Output Rating | 600W | |
| Minimum Load | |||
| Dielectric Voltage Withstand | Input to Output | 1500Vac or 2150Vdc (1 Min.) | |
| Input to Ground | 1500Vac or 2150Vdc (1 Min.) | ||
| Input Transient Susceptibility | Common and Differential Mode (superimposed on AC line) | 2200V | |
| Differential Mode | 1100V | ||
| NOTES:
ProLiant BL e-Class Power Calculator is available from the product page at the
following address: http://www.Compaq.com/products/servers/proliant-bl/e-class/index.html Click "Power Calculator" in the "Support" section. | |||
| | |||
| Non-Hot Plug Ultra ATA/100 Hard Drives | 40 GB 5.4 K | Capacity | 40,007 MB | |
| Height | 0.374 in (9.5 mm) | |||
| Width | 2.756 in (70 mm) | |||
| Interface | Ultra ATA-5 (IDE) 100 MB/s | |||
| Transfer
Rate Synchronous (Maximum) | 27.8 to 44.1 MB/sec (Disk-Buffer) | |||
| Seek
Time (typical reads, including settling) | Single Track | 13 ms | ||
| Rotational Speed | 5,400 RPM | |||
| Physical Configuration | Bytes/Sector | 512 | ||
| Logical Blocks | 78,140,160 (LBA) | |||
| Operating Temperature | 41° to 131° F (5° to 55° C) (Ambient) | |||
|
| ||||
| Two Compaq NC3163 Fast Ethernet NIC Embedded 10/100 WOL (Wake on LAN) | Network Interface | 10Base-T/100Base-TX | |
| Compatibility | IEEE 802.3/802.3u compliant | ||
| Data Transfer Method | 32-bit bus-master PCI | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| Connector | Mates into enclosure center wall assembly | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP; up to 328 ft (100 m) | |
| 100Base-TX | Category 5 UTP; up to 328 ft (100 m) | ||
|
| |||
|
HP ProLiant BL e-Class C-GbE Interconnect Switch | General | Two
24-port Managed Layer 2 Ethernet switches for server network cable reduction Fully pre-configured for immediate operation | |
| Performance | 4.0
Gbps Switching bandwidth 12 Million pps aggregate throughput (64-byte packets) Full-wire speed for all connections | ||
| Forwarding Mode | Store and forward | ||
| MAC Addresses | 16,382; MAC address based filtering and MAC address packet priority configuring | ||
| Memory | 64MB
Main 12MB Flash 32MB Packet Buffer | ||
| Ports | Four
RJ-45 10/100/1000 T/TX/T Gigabit Ethernet uplink ports for customer use Forty 10/100 T/TX fast Ethernet downlink ports dedicated to server blade to interconnect switch network connections Two 10/100 T/TX Fast Ethernet ports dedicated to inter-switch module communications One RS-232 DB-9 port (console connector for Integrated Administrator) One 10/100 T/TX Fast Ethernet port (Network management connector for Integrated Administrator) Auto-negotiation and auto-sensing with full-duplex | ||
| Management | Web-based
interface with graphical user interface Console menu driven Interface via local RS-232 and Telnet Scriptable command line interface (CLI) SNMP v1 (RFC 1157) with scripting tool and example scripts RMON v1 (RFC 1757) groups 1, 2, 3, and 9 Telnet (RFC 854) MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface MIB (RFC 2233), 801.1Q MIB (RFC 2684), RMON1 MIB (RFC 1757) groups 1, 2, 3, and 9, Ethernet MIB (RFC1643) and HP-specific switch MIBs 64 Port-based IEEE 802.1Q tagged VLANs per switch module XML human read/write configuration file TFTP client (RFC 783) for backup and remote download of configuration and history log files IGMP (Internet Group Management Protocol) multicasting EtherChannel (Fast EtherChannel, GigaChannel) compatible trunking Uplink port speed and link activity LEDs Simple network time protocol (SNTP) Broadcast, multicast, and DA-unknown packet storm control BootP and DHCP client support BootP and DHCP client support Port mirroring | ||
| IEEE Standards Compliance | IEEE
802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX Ethernet IEEE 802.3ab 1000Base-T Ethernet IEEE 802.1D Spanning Tree Protocol IEEE 802.1p Quality of Service (QoS) Packet Prioritization IEEE 802.3ac and 802.1Q Port Based Tagged VLANs and VLAN Extensions IEEE 802.1Q Trunking Encapsulation IEEE 802.3x Flow Control | ||
| Form Factor | Removable interconnect tray that plugs into the rear of the server blade enclosure | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-T (Full-Duplex) | 2000 Mb/s | ||
| 1000Base-T (Full-Duplex) | 2000 Mb/s | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP;up to 328 ft (100 m) | |
| 100Base-TX | Category 5 UTP; up to 328 ft (100 m) | ||
| 1000Base-T | Category 5 UTP; up to 328 ft (100 m) | ||
|
| |||
| © Copyright 2004
Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |