Overview
|
HP ProLiant BL20p p-Class Server Blade
| ||||||||||||
|
What's New
|
|
|
|
At A Glance
|
|
|
|
|
|
||||||||||||
|
|
|||||||||||||||||||||||||
| Configuration Steps
|
|
|
Standard Features (Server Blade)
| Processor | Intel Pentium III FC-PGA2 Processor 1.40 GHz |
|
|
|
| Upgradeability | Upgradeable to dual processing |
|
|
|
| Cache Memory | 512-KB Level 2 Cache |
|
|
|
| Chipset | ServerWorks HE- SuperLite Chipset | ||
| NOTE: For more information regarding ServerWorks, please see the following URL: http://www.serverworks.com/products/overview.html. | |||
|
| |||
| Memory | Standard | 512MB PC133-MHz Registered ECC
SDRAM DIMM Memory (2 X 256 MB) (1 processor model) |
| Maximum | 4096 MB | |
| Standard | 1024MB PC133-MHz Registered
ECC SDRAM DIMM Memory (2 x 512 MB) (2 processor model - not available in NA) |
|
| Maximum | 4096 MB | |
| NOTE: Memory must be installed in pairs. | ||
|
|
||
| Network Controller | Four NICs total: Three NC3163 Fast Ethernet 10/100T NICs (embedded) with WOL and PXE One 10/100 NIC dedicated to iLO management Two NC3163 NICs are upgradeable to 10/100/1000T using the Dual Gigabit Ethernet NC7780 NIC option kit |
|
|
|
| Manageability | Integrated Lights-Out (iLO) Management Advanced (ASIC on the System Board) |
|
|
|
| Internal Storage | Hard Drives | None shipped standard |
| Maximum
Internal Storage |
145.6 GB (internal drive cage) (2 x 72.8 GB Ultra320, 1" drives) | |
| | ||
| Expansion Slots | No PCI slots all features are integrated |
|
|
|
| Product Demo | To view the Product Demo,
please see the following URL, then click on "PRODUCT DEMO": http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/index.html. |
|
| |
| ProLiant BL p-Class Server Blade Enclosure and Interconnects | |
| ProLiant BL p-Class Server Blade Enclosure | 6U (10.5-inch), 19-inch wide Holds up to 8 ProLiant BL20p servers blades 10 bays per server blade enclosure 8 bays for server blades 2 outside bays for interconnect modules (RJ-45 Patch Panel, RJ-45 Patch Panel 2, GbE Interconnect Switch, or GbE2 Interconnect Switch) Server blades blind mate into the server blade enclosure backplane for power and data connections Up to 6 BL p-Class 6U server blade enclosures fit in a 42U rack Server blade management module attached to the back of each BL p-Class 6U server blade enclosure to report events all servers and provide asset and inventory information |
|
|
|
| ProLiant BL p-Class Power Requirements |
Redundant 200V - 240V AC, 30
amp single-phase for NA and International Redundant 208V 30amp 3-phase 4 wire, NA Redundant 380 - 415V 20A 3-phase 5 wire, Intl Redundant -48VDC ± 10% |
|
|
Standard Features (Server Blade Enclosure and Interconnects)
| ProLiant
BL p-Class Interconnect Switch Option (Two switches per kit) (Every BL p-Class server blade enclosure requires two interconnect switches OR two RJ-45 patch panels) | Provides
up to a 32 to 1 server networking cable reduction per server enclosure depending
on the mix of BL20p, BL20p G2, and BL40p servers. Each interconnect switch (two
per enclosure) reduces up to sixteen internal server network (NIC) ports to six
external ports (four on a modular rear mounting interconnect module and two on
the switch front panel). This provides a total of twelve external ports per server
blade enclosure. Only one to all twelve external ports may be used per server
blade enclosure. |
|
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet), advanced network feature support including up to layer 7 switching, BL20p G2 Fibre Channel pass-through, and 10 Gigabit Ethernet bandwidth connectivity to the network. Expandability of both layer 3-7 switching and 10 Gigabit Ethernet is supported with future GbE2 Interconnect Switch upgrade options. The optional GbE2 Storage Connectivity Kit is required for BL20p G2 Fibre Channel pass-through when using the GbE2 Interconnect Switch.
| |
| The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet). | |
| |
| Also included (per Interconnect Switch): | |
| |
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).
| |
| ProLiant BL Interconnect Switch Management System and Utilities: | |
| Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support, and more. | |
| | |
| ProLiant
BL p-Class RJ-45 patch panel and Patch Panel 2 (Two patch panels per kit) (Every BL p-Class server blade enclosure requires two Interconnect switches OR two RJ-45 patch panels) | 6U (10.5-inch), Plugs into BL p-Class 6U server blade enclosures |
| Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections | |
| Supports Gigabit Ethernet network controllers | |
| 16 RJ-45 connectors on the back of each BL p-Class 6U RJ-45 patch panel (32 RJ-45 connections per server blade enclosure) | |
| NOTE: The BL20p does not have Fibre Channel functionality. Although the RJ-45 Patch Panel 2 can be used for Ethernet pass through. | |
|
| |
| Required Network Cabling | 10Base-T |
Categories 3, 4 or 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) |
| 100Base-TX | Category
5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) | |
| 1000Base-T |
Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) | |
| !000Base-SX |
50/125 µm Multimode Fiber, 400 MHz/Km (500 meters) 50/125 µm Multimode Fiber, 500 MHz/Km (550 meters) 62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters) 62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters) | |
| NOTE: For cabling information, refer to the Web site at: http://www.hp.com/country/us/eng/prodserv/servers.html. | ||
|
|
Standard Features (Power System and Rack Information)
| ProLiant BL p-Class Power System and Rack Information | NOTE:
To determine power configuration please refer to the ProLiant BL p-Class Overview
and Planning Whitepaper and sizing tool, please see the following URL: http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/20p/documentation.html. |
|
| |
| ProLiant BL p-Class Power Enclosure |
3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Dual input single phase and three phase models available. |
|
BL p-Class power enclosure provides external, shared hot-plug power.
Each three-phase power enclosure houses up to six hot-plug power supplies
each single-phase power enclosures hold up to four hot-plug power supplies
to power the BL p-Class server blades and interconnects |
|
| Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed. | |
|
|
|
| BL p-Class Power Distribution | In the ProLiant BL p-Class infrastructure, redundant -48 VDC power (from the power enclosures or facility DC power) is distributed from the power enclosures to the server blade enclosures through the bus bar system. Hinges attach the ProLiant BL bus bars to the rails in a rack. The bus bars swing open from the center to enable easy rear access to the server blades and network cables. Power is distributed redundantly through independent A- and B-sided bus bars. |
| Three different power distribution solutions are available depending on the maximum number of server blade enclosures planned for the rack: | |
|
|
| NOTE: To support a full 42U rack of BL20p server blades (6 server blade enclosures), two mini bus bars are needed. | |
|
|
Power Enclosures Supported |
Server Blade Enclosures Supported |
Max. Rack Space Occupied |
|
|
Scalable Bus Bar |
1 or 2 |
up to 5 |
36U |
|
Mini Bus Bar |
1 |
up to 3 |
21U |
| Power Bus Box |
1 |
1 |
9U |
| Required Power Source | Two 30amp redundant power feeds per power enclosure | |||
| Connectors | ||||
| NEMA receptacles (NA/Japan) | ||||
| NA 1-phase | L6-30, 250v, 30A 3-wire | |||
| NA 3-phase | L15-30, 250V, 30A, 4-wire | |||
| IEC 309 Pin & Sleeve connectors (International) | ||||
| Intl 1-phase | 250V, 32A, 3- pin (2 pole + ground) | |||
| Intl 3-phase | 380-415V, 32A, 5--pin (4 pole + ground) | |||
| Optimized
for power cabling from bottom and network cabling from top For cabling information, refer to the Web site at http://www.hp.com/country/us/eng/prodserv/servers.html. | ||||
|
|
Standard Features
|
ProLiant Essentials Foundation Pack Software for the ProLiant BL Server |
|
||
|
|||
|
|||
|
|||
|
|||
|
|||
| NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. | |||
|
|
|||
| Optional ProLiant Essentials Value Packs |
Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs:
|
|
|
|
| SmartStart | SmartStart is a tool that simplifies
single server setup, providing a rapid way to deploy reliable and consistent
server configurations. SmartStart 7.00 and later can now deploy the ProLiant
BL20P G3 and ProLiant BL40P servers, using the I/O port with an attached
USB CD-ROM device. To obtain a copy of SmartStart for your blade server,
redeem the coupon that is included with your Blade server or order your
copy from the SmartStart web site. For more information, please visit the
SmartStart Web site at http://www.hp.com/servers/smartstart. SmartStart version supported (minimum): SmartStart 6.20 |
|
|
|
| OS Support | Microsoftฎ Windows LINUX |
| NOTE: For a
more complete and up-to-date listing of supported OSs and versions, please
visit our OS Support Matrix at:http://www.hp.com/go/supportos. NOTE: For an up-to-date listing of the latest drivers available for the ProLiant BL p-Class, please see: http://h18023.www1.hp.com/support/files/server/us/index.htm. NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux Web site at http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html . |
|
| | |
| Intelligent Manageability | Integrated Lights-Out Advanced
(iLO) Virtual Text and Graphical Remote Console * Virtual CD-ROM * Virtual Floppy * Virtual Power Button Control Dedicated LAN Connectivity Automatic IP Configuration via DHCP/DNS/WINS Industry Standard 128-bit Secure Sockets Layer (SSL) Security IML and iLO Event Logging Support for 12 user accounts with customizable access privileges Automatic Server Recovery-2 (ASR-2) Insight Manager 7 Redundant ROM Remote Flash ROM ROM Based Setup Utility (RBSU) Advanced Configuration and Power Interface Specification Ready (ACPI) Server and Interconnect Switch Health Logs Redundant Power Supply Utility Pre-Failure Warranty (covers processors, as well as hard drives and memory) Interconnect Switch Management System and Utilities (interconnect switch option) Integrated Management Log (IML) Hot Spare Boot (NOTE: Upon the event of a failed processor or VRM in a multi-processing environment, the system will automatically reboot and use the remaining good processor(s).) Dynamic sector repairing and drive parameter tracking (with Smart Array controllers) ProLiant network adapter teaming set-up utility *NOTE: Advanced features such as Graphical Remote Console and Virtual Floppy are included with the BL p-Class server. |
|
|
|
| Availability |
Power redundancy: Redundant AC feeds into power enclosures, redundant
DC feeds from power enclosure to server blade enclosures, N + N redundant
power supplies
|
|
|
|
| Security | Power-on
password Administrator's password Integrated Lights-Out has 12 customizable user accounts and SSL encryption Integrated Lights-Out can be disabled via a Global Setting Interconnect switch multilevel user names and passwords, management interface time out period setting, SSH*, SCP secure copy protocol*, port-based IEEE 802.1Q tagged VLANs, RADIUS user authentication and authorization*, and IP address restriction * GbE2 Interconnect Switch only. |
| | |
| Minimum Rack Requirements |
Mounts in Compaq/HP, Telco racks and Third Party racks that meet the following criteria:
|
| NOTE: If using HP 7000 Series rack, Rack Extension Kit and High Air Flow Rack Door options are required. | |
|
|
|
| Rack Airflow Requirements |
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://wwss1pro.compaq.com/support/home/index.asp | |
|
| |
| Service and Support |
Three-year limited warranty, including hardware diagnostic support, pre-failure
warranty (coverage of hard drives, memory and processors). The warranty
is fully supported by HP Services and a worldwide network of resellers
and service providers. In addition 90-day's getting started software telephone
support may be covered under the warranty or available for an additional
fee. Enhancements to warranty services are available through HP Care Pack
services. A full range of HP Care Pack hardware and software services are available including:
HP Care Pack services for ProLiant BL p-Class server blades, cover the server blade and the p-Class blade enclosure that the server blade is installed in as well as interconnects, power enclosure with power supplies and power distribution. |
| NOTE: For more
information on HP Care Pack services, contact any of our worldwide sales
offices or resellers or visit our worldwide Web site on the internet at:
http://www.hp.com/hps/carepack. NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at: http://www.hp.com/hps. NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html. |
|
|
Models
| ProLiant BL20p P1400-512KB,
512MB (1P) 230040-B21 |
Processor(s) | (1) Intel Pentium III 1.40 GHz standard (up to 2 supported) |
| Cache Memory | 512-KB Level 2 writeback per processor | |
| Memory | 512 MB (Standard) (2 X 256MB) to 4096 MB PC133-MHz Registered ECC SDRAM DIMM Memory | |
| Network Controller | Three NC3163 Fast Ethernet NIC
PCI 10/100 with full WOL and PXE One additional 10/100 port dedicated to iLO Management |
|
| Storage Controller | Smart Array 5i Controller (integrated on system board) | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 145.6-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into ProLiant BL p-Class Server Blade Enclosure | |
|
|
||
|
ProLiant BL20p P1400-512KB, 1GB (2P) *Not available in North America. |
Processor(s) | (2) Intel Pentium III 1.40 GHz standard (up to 2 supported) |
| Cache Memory | 512-KB Level 2 writeback per processor | |
| Memory | 1024 MB (Standard) (2 X 512MB) to 4096 MB PC133-MHz Registered ECC SDRAM DIMM Memory | |
| Network Controller | Three NC3163 Fast Ethernet NIC
PCI 10/100 with full WOL and PXE One additional 10/100 port dedicated to iLO Management |
|
| Storage Controller | Smart Array 5i Controller (integrated on system board) | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 145.6-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into ProLiant BL p-Class Server Blade Enclosure |
|
|
Options
| ProLiant BL20p Unique Options | Dual NC7780 Gigabit Upgrade Module for ProLiant BL20p |
230255-B21
|
| NOTE: The Dual NC7780 Gigabit Upgrade Module replaces two of the standard NC3163 Fast Ethernet Embedded WOL and PXE NICs to two 10/10/1000T NC7780 NICs. | ||
| NOTE: The GbE Interconnect Switch options support server NIC speeds to 100 Mbps. It is recommended that the patch panel or GbE2 Interconnect Switch options be used with the Dual NC7780 Gigabit Upgrade Module if server NIC speeds to 1000 Mbps are required. | ||
|
|
||
| ProLiant
Essentials Value Pack Software |
Rapid Deployment
Pack, 10 User, V1.x NOTE: This license allows 10 servers to be managed and deployed via the Deployment Server. NOTE: Not necessary if you purchase the server blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21. |
306696-B21 |
| Rapid
Deployment Pack, 10 User, V1.x (Japan) NOTE: This license allows 10 servers to be managed and deployed via the Deployment Server. NOTE: Not necessary if you purchase the server blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21. |
269817-291
|
|
| Rapid
Deployment Pack, 1 User, V1.x NOTE: This license allows 1 server to be managed and deployed via the Deployment Server. NOTE: Not necessary if you purchase the server blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21. |
267196-B21
|
|
| Rapid
Deployment Pack, 1 User, V1.x (Japan) NOTE: This license allows 1 server to be managed and deployed via the Deployment Server. NOTE: Not necessary if you purchase the server blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21. |
267196-291
|
|
| ProLiant Essentials Workload Management Pack (Featuring Resource Partitioning Manager version 2.0) |
303284-B21
|
|
| ProLiant
Essentials Performance Management Pack, 10-Server License NOTE: For use with up to 10 servers. Contains 10 licenses with one unique license activation key and documentation. |
374055-B21
|
|
| ProLiant
Essentials Intelligent Networking Pack, Single Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372906-B21
|
|
| ProLiant
Essentials Intelligent Networking Pack, Flexible License NOTE: For use with multiple servers. This part number can be used to purchase multiple licenses with a single activation key. The quantity ordered for this part number will be the quantity of licenses included in the kit in the form of a corresponding activation key. Use the same key to activate all licenses in the actual quantity ordered. For a given order, one kit will be delivered with the activation key, and documentation. |
372950-B21
|
|
| ProLiant
Essentials Intelligent Networking Pack, Tracking License NOTE: For use with signed and implemented Activation Key Agreements only. Purchase of this part number entitles the customer to deploy additional licenses of the product under the terms of the existing Activation Key Agreement. NOTE: Nothing is delivered in conjunction with the purchase of this part number. Visit http://h18004.www1.hp.com/products/servers/proliantessentials/license/akalic.html for more information on Activation Key Agreements. |
372951-B21
|
|
| NOTE:
For more information regarding ProLiant Essentials Software, please see
the following URL: http://www.hp.com/servers/proliantessentials NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to URL http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. |
||
|
|
||
| Processor | Pentium III P1400-512KB
Processor Option Kit |
234277-B21 |
|
|
||
|
Memory |
2048 MB PC133MHz Registered ECC SDRAM Memory Kit (2x1024 MB) |
201695-B21
|
| 1024 MB PC133MHz Registered ECC SDRAM Memory Kit (2x512 MB) |
201694-B21
|
|
| 512 MB PC133MHz Registered ECC SDRAM Memory Kit (2x256 MB) |
201693-B21
|
|
| 256 MB PC133MHz Registered ECC SDRAM Memory Kit (2x128 MB) |
201692-B21
|
|
|
|
||
| Hard Drives | Ultra 320 SCSI Universal Hot Plug | |
| 72.8GB 10,000 rpm, U320 Universal Hard Drive, 1" |
286714-B22
|
|
| 300-GB 10,000 rpm, U320 Universal Hard Drive 1" |
350964-B22
|
|
| 36.4GB 15,000 rpm, U320 Universal Hard Drive, 1" |
286776-B22
|
|
| 72.8GB 15,000 rpm, U320 Universal Hard Drive, 1" |
286778-B22
|
|
| NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. | ||
| NOTE: Please see
the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature: U320 Hard Drive QS: http://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.HTML (Worldwide) http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.HTML (North America) |
||
|
|
||
| Storage Controllers | Battery Backed Write Cache Enabler Option Kit | 255514-B21 |
| Battery Backed Write Cache Enabler Option Kit (Japan) | 255514-291 | |
| NOTE: Please
see the following Controller QuickSpecs for Technical Specifications such as PCI
Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak Data Transfer
Rate, Channels, SCSI Ports, Drives supported, Cache, RAID support, and additional
information: http://h18000.www1.hp.com/products/quickspecs/11063_div/11063_div.HTML (Smart Array 5I) | ||
| | ||
| Communications |
Dual NC7780 Gigabit Upgrade Module for ProLiant BL20p |
230255-B21 |
|
NOTE: The Dual NC7780 Gigabit Upgrade Module replaces two of the standard NC3163 Fast Ethernet Embedded WOL (Wake On LAN) NICs to two 10/10/1000T NC7780 NICs. |
|
|
|
NOTE: The GbE Interconnect Switch options support server NIC speeds to 100 Mbps. It is recommended that the patch panel or GbE2 Interconnect Switch options be used with the Dual NC7780 Gigabit Upgrade Module if server NIC speeds to 1000 Mbps are required. |
|
|
|
|
||
| BL p-Class Server Blade Enclosures | ProLiant BL p-Class Server Blade Enclosure (ProLiant Essentials Rapid Deployment Pack Trial) |
243564-B21 |
| ProLiant BL p-Class Server Blade Enclosure (8 ProLiant Essentials Rapid Deployment Pack Licenses) |
281404-B21 |
|
|
|
||
| BL p-Class Interconnects |
ProLiant BL p-Class RJ-45 Patch Panel (pair) |
230766-B21 |
| NOTE: Only one interconnect kit required per server blade enclosure. | ||
| ProLiant BL p-Class RJ-45 Patch Panel 2 (pair) |
306465-B21
|
|
| NOTE:
Only one interconnect kit required per server blade enclosure. |
||
| ProLiant BL p-Class C-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadT2 Interconnect Modules) |
283192-B21
|
|
| NOTE: Only one interconnect kit required per server blade enclosure. | ||
| ProLiant BL p-Class F-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadSX Interconnect Modules) |
283193-B21
|
|
| NOTE: Only one interconnect kit required per server blade enclosure. | ||
| ProLiant BL p-Class C-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two QuadT Interconnect Modules) |
249655-B21
|
|
| NOTE: Only one interconnect kit required per server blade enclosure. | ||
| NOTE: The GbE
Interconnect Switch supports server NIC speeds to 100 Mbps. It is recommended
that the GbE2 Interconnect Kit or patch panel be used if server NIC speeds
to 1000 Mbps are required. NOTE: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit. |
||
| ProLiant BL p-Class F-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two DualTSX Interconnect Modules) |
279720-B21
|
|
| NOTE: Only one interconnect kit required per server blade enclosure. | ||
| NOTE:
The GbE Interconnect Switch supports server NIC speeds to 100 Mbps. It is
recommended that the GbE2 Interconnect Kit or patch panel be used if server
NIC speeds to 1000 Mbps are required. NOTE: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit. |
||
|
|
||
| BL p-Class Power options | NOTE:
Use p-Class sizing tool to help determine power configuration: http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls |
|
| Single Phase Redundant Power Enclosure with 4 power supplies (NA/JPN) |
239162-001 | |
| (Single Phase Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit) | ||
| Single Phase Redundant Power Enclosure with 4 power supplies (Int'l) |
239162-421 | |
| (Single Phase Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit) | ||
| 3 Phase Redundant Power Enclosure with 6 power supplies (NA/JPN) |
230769-001 | |
| (3 Phase Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit) | ||
| 3 Phase Redundant Power Enclosure with 6 power supplies (Int'l) |
230769-421 | |
| (3 Phase Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit) | ||
| Single
Phase Power Enclosure (empty) (NA/JPN) (Holds up to 4 power supplies; power supplies are not included in this kit) |
231710-001 | |
| Single
Phase Power Enclosure (empty) (Int'l) (Holds up to 4 power supplies; power supplies are not included in this kit) |
231710-421 | |
| 3
Phase Power Enclosure (empty) (NA/JPN) (Holds up to 6 power supplies; power supplies are not included in this kit) |
231709-001 | |
| 3
Phase Power Enclosure (empty) (Int'l) (Holds up to 6 power supplies; power supplies are not included in this kit) |
231709-421 | |
| Single Power Supply | 239161-B21 | |
| Facility DC Power Connection | 240563-B21 | |
| | ||
| Power Distribution | ProLiant p-Class Scalable Bus Bar | 240560-B21 |
| ProLiant p-Class Mini Bus Bar | 240559-B21 | |
| ProLiant p-Class Mini Bus Bar | 240562-B21 | |
| | ||
| Diagnostic Options | ProLiant p-Class Diagnostic Station | 230743-B21 |
| NOTE: The Diagnostic Station allows access to the ProLiant BL20p server blade and the BL p-Class interconnect switch outside of the server enclosure. The option provides power and a data interface so that "offline" upgrade and diagnostic functions may be performed. | ||
| | ||
| USB Options | USB Easy Access Keyboard (Carbonite/Silver) |
DC168B# |
| USB Optical Scroll Mouse (Carbonite) | DD441B | |
| USB 1.44-MB External Diskette Drive (Carbonite) |
DC141B |
| USB Easy Access Keyboard (Carbonite) Country Key Code | ||||
| Dash # | Description | Dash # | Description | |
| A2M | ICELAND | ABT | HE | |
| AB0 | TAWA | ABU | UK | |
| AB1 | KOR | ABV | ARA | |
| AB2 | PRC | ABX | FIN | |
| AB6 | FRA | ABY | DEN | |
| AB7 | GRK | ABZ | ITL | |
| AB8 | TURK | AC0 | BEL | |
| AB9 | PORT | AC4 | BRZ | |
| ABA | US | ACB | RUSS | |
| ABB | EURO | AKB | CZE | |
| ABC | FCAN | AKC | HUNG | |
| ABD | GR | AKD | POL | |
| ABE | SP | AKL | THAI | |
| ABF | FR | AKN | BHCSY | |
| ABH | NL | AKR | SLOV | |
| ABJ | Japan | ARK | ICELAND | |
| ABM | LA | B15 | KAZ | |
| ABN | NOR | UUZ | SWISS | |
| ABS | SW | |||
|
|
||||
| Custom Builder | Please see the Enterprise Configurator for configuration assistance at: http://www.hp.com/products/configurator. |
| | |
|
HP Rack 10000 Series | S10614 (14U) Rack Cabinet - Shock Pallet | 292302-B22 |
| HP Rack 10647 (47U) Pallet |
245160-B21 | |
|
HP Rack 10647 (47U) Crated |
245160-B23 | |
|
HP Rack 10642 (42U) Pallet |
245161-B21 | |
|
HP Rack 10642 (42U) Shock Pallet |
245161-B22 | |
|
HP Rack 10642 (42U) Crated |
245161-B23 | |
|
HP Rack 10636 (36U) Pallet |
245162-B21 | |
|
HP Rack 10636 (36U) Shock Pallet |
245162-B22 | |
|
HP Rack 10636 (36U) Crated |
245162-B23 | |
|
HP Rack 10622 (22U) Pallet |
245163-B21 | |
|
HP Rack 10622 (22U) Shock Pallet |
245163-B22 | |
|
HP Rack 10622 (22U) Crated |
245163-B23 | |
| NOTE:
-B21 (pallet) used to ship empty racks shipped on a truck -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels) -B23 (crated) used for air shipments of empty racks Not all Compaq equipment is qualified to be shipped in the Rack 10000 series. | ||
| NOTE:
Please see the Rack 10000 QuickSpecs for Technical Specifications such as
height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.HTML (Worldwide) http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.HTML (North America) | ||
| NOTE:
For additional information regarding Rack Cabinets, please see the following
URL: http://h18000.www1.hp.com/products/servers/proliantstorage/racks/index.html. |
||
| | ||
| Rack Options for
HP Rack 10000 Series |
HP Rack Plinth Kit (Carbon) | 251960-B21 | |||||||
| HP Rack Light Kit (Neon) | 361589-B21 | ||||||||
| 800mm Wide Stabilizer Kit (Graphite) | 255488-B21 | ||||||||
| NOTE: Supported by the Rack 10842 cabinet only. | |||||||||
| 600mm Stabilizer Kit Graphite | 246107-B21 | ||||||||
| Baying Kit for Rack 10000 series (Carbon) | 248929-B21 | ||||||||
| 42U Side Panel Graphite Metallic | 246099-B21 | ||||||||
| 110V Fan Kit (Graphite) | 257413-B21 | ||||||||
| NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 5-15P. | |||||||||
| 220V Fan Kit (Graphite) | 257414-B21 | ||||||||
| NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 6-15P. | |||||||||
| 36U Side Panel Graphite Metallic | 246102-B21 | ||||||||
| 47U Side Panel Graphite Metallic | 255486-B21 | ||||||||
| 9000/10000 Series Offset Baying Kit (42U) | 248931-B21 | ||||||||
| NOTE: This kit can be used to connect 9000 and 10000 series racks of the same U height together. Kit contents include hardware for connecting racks and a panel to cover the 100mm gap at the rear of the two racks. | |||||||||
| NOTE: For additional information regarding Rack Options, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. | |||||||||
| Ballast Option Kit |
120672-B21
|
||||||||
| 9000/10000 Series Offset Baying Kit (42U) |
248931-B21
|
||||||||
| NOTE: This kit can be used to connect 9000 and 10000 series racks of the same U height together. Kit contents include hardware for connecting racks and a panel to cover the 100mm gap at the rear of the two racks. | |||||||||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html | |||||||||
| Rack Rail Adapter Kit (25" depth) | 120675-B21 | ||||||||
| 100 kg Sliding Shelf | 234672-B21 | ||||||||
| Monitor/Utility Shelf - Graphite | 253449-B21 | ||||||||
| Depth Adjustable Fixed Rail | 332558-B21 | ||||||||
| Cable Management D-Rings Kit | 168233-B21 | ||||||||
| Server Console Switch 1 x 4 port (100-230 VAC) | 400336-001 | ||||||||
| Server Console Switch 1 x 4 port (100-230 VAC) (Intl) | 400336-B31 | ||||||||
| Server Console Switch 1 x 4 port (100-230 VAC) (Japan) | 400336-291 | ||||||||
| IP Console Switch Box, 1 x 1 x 16 | 262585-B21 | ||||||||
| IP Console Switch Box, 3 x 1 x 16 | 262586-B21 | ||||||||
| CPU to Server Console Cable, 12 | 110936-B21 | ||||||||
| CPU to Server Console Cable, 3 | 110936-B24 | ||||||||
| CPU to Server Console Cable, 7 | 110936-B25 | ||||||||
| IP CAT5 Cable 3, 4 pack | 263474-B21 | ||||||||
| IP CAT5 Cable 6, 8 pack | 263474-B22 | ||||||||
| IP CAT5 Cable 12, 8 pack | 263474-B23 | ||||||||
| IP CAT5 Cable 20, 4 pack | 263474-B24 | ||||||||
| IP CAT5 Cable 40, 1 pack | 263474-B25 | ||||||||
|
Switch Box Connector Kit (high voltage) (Int'l) |
144007-B33 | ||||||||
| TFT5600 Rack Keyboard Monitor | 221546-xx1 | ||||||||
| TFT7210R Rack Mounted 17" Monitor | 348373-B21 | ||||||||
| NOTE:
For a complete list of Monitors please view the following URL: http://h18004.www1.hp.com/products/monitors/ |
|||||||||
| 1U Rack Keyboard & Drawer (Carbon) |
257054-xx1
|
||||||||
| Country Code Key(for 1U Rack Keyboard & Drawer (PN 257054-xx1)) | |||||||||
|