HP ProLiant BL40p Server Blade

42U Rack with HP ProLiant BL40p System Installed
 
1.
BL p-Class Interconnects (2) in HP BladeSystem p-Class server blade enclosure (interconnect switch shown
2.
HP ProLiant BL40p server blades (2) in HP BladeSystem p-Class server blade enclosure
3.
HP BladeSystem p-Class 3U power enclosure with hot-plug power supplies (6)
What's New
  • New HP BladeSystem p-Class 1U Power Enclosure
  • The HP BladeSystem Management Suite is delivered in a convenient to purchase pack which includes a BL p-Class Server Blade Enclosure with enhanced backplane components, a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM).

HP ProLiant BL40p Server Blade includes:

  • Intel Xeon MP FC-PGA 3.0GHz\4MB or 2.2GHz\2MB processor (quad capability)
  • ServerWorks GC-LE Chipset
  • 512-MB or 1024 MB of 2-way interleaved PC2100 ECC DDR (2 x 1 Interleaved Memory), expandable to 12 GB
  • Advanced Memory Protection with Online Spare
  • Five NC7781 PCI-X Gigabit NICs (embedded) with WOL (Wake On LAN) and Preboot eXecution Environment (PXE)
  • One additional 10/100T NIC dedicated to Integrated Lights-Out (iLO) Management
  • Smart Array 5i Plus Controller with battery-backed write cache (integrated on system board) standard on the 3.0GHz/4M model, optional on the 2.2GHz/2M model
  • Wide Ultra3 SCSI Drive Cage standard supports up to four 1" hot plug hard drives
  • Two PCI-X slots (64b/100MHz capable) for redundant SAN connectivity
  • Integrated Lights-Out (iLO) Management (ASIC on motherboard)
  • Plugs vertically into p-Class server enclosure
  • Up to 12 HP ProLiant BL40p server blades fit in 42U rack

What's Needed

HP BladeSystem p-Class Server Blade Enclosure:

  • Server blades and interconnects slide into p-Class server blade enclosures for network connection and power
  • Server blade enclosure is 6U high and 10 bays across. The server blade enclosure bays consist of 2 (outer) interconnect bays and 8 server bays. One server blade enclosure can hold up to 2 HP ProLiant BL40p server blades and 2 interconnects
  • Types of interconnects available: GbE Interconnect Switches, GbE2 and CGESM Interconnect Switches with optional Fibre Channel pass through, Patch Panels or Patch Panel 2 with Fibre Channel pass through

HP BladeSystem p-Class Power Enclosures:

  • Use BL p-Class sizing tool to determine power based on your configuration http://h30099.www3.hp.com/configurator/powercalcs.asp
  • Choose the HP BladeSystem p-Class 3U power enclosure or the HP BladeSystem p-Class 1U power enclosure
  • Choose single-phase or three-phase power
  • HP BladeSystem power enclosures with power supplies are not needed if using facility -48VDC ± 10%, in this case purchase facility DC option kit

HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):

  • Distributes power from the power enclosure to the server blade enclosures
  • Four power distribution choices:
    • HP BladeSystem p-Class scalable bus bar
    • HP BladeSystem p-Class mini bus bar
    • HP BladeSystem p-Class power bus box
    • Dual power input kit for mini bus bar (required for support of two power enclosures
  • NOTE: Power requirements for a HP BladeSystem p-Class: 200V - 240V AC, 30 amp or facility DC -48V ± 10%.
  • HP ProLiant BL40p server blade, p-Class server blade enclosures, interconnects and power enclosures protected by a limited three year warranty with optional service uplifts available
  • SATA drives have a 1 year warranty
HP ProLiant BL40p Server Blade
+
 
HP BladeSystem p-Class Server Blade Enclosure
+
 
OR
 
 
Patch Panel (shown) or Patch Panel 2
GbE Interconnect Switch (shown) or GbE2 Interconnect Switch or CGESM Interconnect Switch
(fiber or copper-based)
 
HP BladeSystem p-Class Interconnects
 
+
HP BladeSystem p-Class 3U power enclosures and power supplies
OR
 
 
HP BladeSystem p-Class 1U power enclosures and power supplies
OR
Facility DC
+
 
OR
OR
Scalable bus bar
HP BladeSystem p-Class power distribution
Bus boxes

Configuration Steps

For a complete configuration of the HP ProLiant BL40p server blade, do the following:

  1. Select a HP ProLiant BL40p server blade:
    Single Xeon MP 2.2GHz processor, 512-MB RAM (2 x 256MB) (345628-B21)
    Or
    Single Xeon MP 3.0GHz processor, 1-GB RAM (2 X 512M) (344286-B21)
    NOTE: Additional options include processors, memory, and PCI-X HBAs.

    PLUS

  2. Decide how many HP BladeSystem p-Class Server Blade Enclosures to purchase (each enclosure can hold up to 2 HP ProLiant BL40p server blades):

    HP BladeSystem p-Class server blade enclosure with enhanced backplane components with 8 Rapid Deployment Pack licenses (281404-B22)
    Or
    HP BladeSystem p-Class server blade enclosure with enhanced backplane components with Rapid Deployment Pack trial (243564-B22)
    Or
    HP BladeSystem p-Class server blade enclosure with enhanced backplane components and the HP BladeSystem Management Suite which is delivered in a convenient to purchase pack that includes a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM).(380625-B22)
    Or
    Optional HP BladeSystem p-Class Server Blade Enclosure Upgrade Kit(354100-B21)

    PLUS

    Select an Interconnect Kit. Each Interconnect Kit contains a pair of interconnects except the Cisco GESM which contains a single switch per kit. One pair of interconnects is required with each ProLiant BL p-Class server blade enclosure:

    BL p-Class RJ-45 Patch Panel (with 32 RJ-45 connectors) (230766-B21)
    Or
    Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports) (378926-B21), with or without any combination of up to 4 10/100/1000 T/TX/T RJ-45 SFP Module (378928-B21) or 1000BASE SX Fiber SFP Module (378929-B21), with or without ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLxxp xx Fibre Channel connectivity when using the CGESM Interconnect Switch)
    Or
    Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports populated with 2 10/100/1000 T/TX/T SFP modules) (378927-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLxxp xx Fibre Channel connectivity when using the CGESM Interconnect Switch)
    Or
    BL p-Class C-GbE2 Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 6 RJ-45 10/100/1000 T/TX/T uplink ports ) (283192-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLxxp xx Fibre Channel connectivity when using the GbE2 Interconnect Switch) or BL p-Class F-GbE2 Interconnect (with 16 10/100/1000 T/TX/T downlink ports, 4 LC 1000 SX and 2 RJ-45 10/100/1000 T/TX/T uplink ports) (283193-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLxxp xx Fibre Channel connectivity when using the GbE2 Interconnect Switch)
    Or
    BL p-Class C-GbE Interconnect Kit (with 4 RJ-45 10/100/1000 T/TX/T uplink ports and 16 RJ-45 10/100 T/TX downlink ports (249655-B21)
    Or
    BL p-Class F-GbE Interconnect Kit (with 4 LC 1000 SX uplink ports and 16 RJ-45 10/100 T/TX downlink ports) (279720-B21) Or
    BL p-Class server blade enclosure with enhanced backplane components with 8 Rapid Deployment Pack licenses (281404-B22)
    Or
    BL p-Class server blade enclosure with enhanced backplane components with 8 Rapid Deployment Pack trial (243564-B22)
    Or
    Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports) (378926-B21), with or without any combination of up to 4 10/100/1000 T/TX/T RJ-45 SFP Module (378928-B21) or 1000BASE SX Fiber SFP Module (378929-B21), with or without ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLxxp xx Fibre Channel connectivity when using the CGESM Interconnect Switch)
    Or
    Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports populated with 2 10/100/1000 T/TX/T SFP modules) (378927-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLxxp xx Fibre Channel connectivity when using the GbE2 Interconnect Switch) or BL p-Class C-GbE2 Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 6 RJ-45 10/100/1000 T/TX/T uplink ports ) (283192-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLxxp xx Fibre Channel connectivity when using the CGESM Interconnect Switch)
    Or
    BL p-Class F-GbE2 Interconnect (with 16 10/100/1000 T/TX/T downlink ports, 4 LC 1000 SX and 2 RJ-45 10/100/1000 T/TX/T uplink ports) (283193-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLxxp xx Fibre Channel connectivity when using the GbE2 Interconnect Switch)
    Or
    BL p-Class C-GbE Interconnect Kit (with 4 RJ-45 10/100/1000 T/TX/T uplink ports and 16 RJ-45 10/100 T/TX downlink ports (249655-B21)
    Or
    BL p-Class F-GbE Interconnect Kit (with 4 LC 1000 SX uplink ports and 16 RJ-45 10/100 T/TX downlink ports) (279720-B21)

  3. Select a HP ProLiant BL40p server blade:
    Single Xeon MP 2.2GHz processor, 512-MB RAM (2 x 256MB) (345628-B21)
    Or
    Single Xeon MP 3.0GHz processor, 1-GB RAM (2 X 512M) (344286-B21)
    NOTE: Additional options include processors, memory, and PCI-X HBAs.

    PLUS

  4. Decide how many HP BladeSystem p-Class Server Blade Enclosures to purchase (each enclosure can hold up to 2 HP ProLiant BL40p server blades):

    HP BladeSystem p-Class server blade enclosure with enhanced backplane components and the HP BladeSystem Management Suite which is delivered in a convenient to purchase pack that includes a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM).(380625-B22)
    NOTE: The HP ProLiant BL40p server blade does not currently support (PMP). Future support is planned.

    PLUS

  5. Select a HP BladeSystem p-Class power enclosure and power supplies based on configuration. Use p-Class sizing tool to help determine power configuration: http://h30099.www3.hp.com/configurator/powercalcs.asp
    NOTE: Power enclosures and supplies are not needed if using facility DC (-48V ± 10%).
    Single phase 3U power enclosure with four hot-plug power supplies (NA/JPN- 239162-001) (Single-phase 3U power enclosure holds a max of four power supplies; no need to order additional power supplies with this option kit) (INTL - 239162-421)
    Or
    Three-phase 3U power enclosure with six hot-plug power supplies (NA/JPN- 230769-001) (INTL - 230769-421) (Three-phase 3U power enclosure holds a max of six power supplies no need to order additional power supplies with this option kit)
    (Power enclosures and power supplies can also be purchased separately. See options list below.)
    Or
    1U power enclosure with six power supplies (378284-B21)
    Or
    1U power enclosure with two power supplies (380314-B21) (Additional power supplies can also be purchased separately. See options list below.)

    PLUS

    Select power distribution (only required with 3U power enclosures):
    Scalable bus bar - Supports up to 5 server blade enclosures* (240560-B21)
    Or
    Mini bus bar - Supports up to 3 server blade enclosures* (240559-B21)
    Or
    Power Bus Box - Supports only 1 server blade enclosure* (240562-B21)
    Or
    Dual Power Input Kit for Mini Bus Bar - required for support of two power enclosures. (364565-B21)
    Or
    HP Modular Distribution Unit 40 Amp (NA/JPN) (P/N 252663-D75)**
    Or
    HP Modular Distribution Unit 40 Amp (Int'l) (P/N 252663-B34)** Or HP Modular Distribution Unit 32 Amp (Int'l) (P/N 252663-B33)**
    Or
    HP Modular Distribution Unit 24 Amp (NA/JPN) (P/N 252663-D74)**
    *NOTE: Maximum depends upon power input.
    **NOTE: The Modular Distribution Unit Kits excludes the extension bars as they are not required with the HP BladeSystem p-class 1U power enclosure.
contents
 Overview      Standard Features (Server Blade)      Standard Features (Server Blade Enclosure and Interconnects)      Standard Features (Power System and Rack Information)      Standard Features      Models      Options      Memory      Technical Specifications line.gif (50 bytes)

Standard Features (Server Blade)

HP ProLiant BL40p Server Blade
Processor
One of the following depending on Model:
Xeon MP processor 3.0 GHz/4MB
Xeon MP processor 2.2 GHz/2MB

Upgradeability Upgradeable to quad processing

Cache Memory 4-MB Level 3 Cache (on the 3.0GHz Model)
2-MB Level 3 Cache (on the 2.2GHz Models)

Chipset ServerWorks GC-LE chipset
NOTE: For more information regarding ServerWorks, please see the following URL:
http://www.serverworks.com/products/overview.html.

Memory Protection Advanced Memory Protection with Online Spare

Memory Type
2-way interleaved PC2100 ECC DDR (2 X 256 MB)
Standard
512MB
(1 processor model)
Maximum
12,288 MB
(2 X 512MB)
Standard
1024MB
(2 processor model)
Maximum 12,288 MB
NOTE: Memory must be installed in pairs. Advanced Memory Protection with Online Spare.

Network Controller Six network adapters total:
 Five NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
 One 10/100T iLO NIC dedicated to management

Manageability Integrated Lights-Out (iLO) Management Advanced (ASIC on the System Board)

Internal Storage Hard Drives None ship standard
Maximum Internal
Storage
SCSI 1200 GB (internal drive cage) (4 x 300 GB)
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds.

Expansion Slots Two Dedicated PCI-X slots (64b/100MHz capable) for redundant SAN connectivity
I/O cable I/O cable connectors:
(2)USB ports, (1) video port, (1) iLO port and (1) kernel debug port
(2) I/O cables ship with every server blade enclosure
Tested USB devices (keyboard, mouse, floppy) are listed in options section of this QuickSpecs

Dimensions 6U high x 7" wide. Fits within p-Class Server Blade Enclosure. One HP ProLiant BL40p server blade takes up four (4) server blade bays within a server blade enclosure. Two HP ProLiant BL40p server blades can fit within one server blade enclosure.
contents
 Overview      Standard Features (Server Blade)      Standard Features (Server Blade Enclosure and Interconnects)      Standard Features (Power System and Rack Information)      Standard Features      Models      Options      Memory      Technical Specifications line.gif (50 bytes)

Standard Features (Server Blade Enclosure and Interconnects)

HP BladeSystem p-Class Server Blade Enclosure and ProLiant BL p-Class Interconnects
HP BladeSystem p-Class Server Blade Enclosure

6U (10.5-inch), 19-inch wide
Holds up to 2 HP ProLiant BL40p server blades; 8 HP ProLiant BL20p server blades; or a combination of both.

10 bays per server blade enclosure:

  • 8 bays for server blades
  • 2 outside bays for interconnect modules (RJ-45 Patch Panels, RJ-45 Patch Panel 2, GbE2 Interconnect Switches, GbE Interconnect Switch or CGESM Interconnect Switch)

Server blades slide in and connect to the server blade enclosure back plane for power and data connections
Up to 6 BL p-Class server blade enclosures fit in a 42U rack
Server blade management module attached to the back of each BL p-Class server blade enclosure to report all server events and provide asset and inventory information


HP BladeSystem p-Class Power Requirements Redundant 200V - 240V AC, 30 amp single-phase for NA and International
Redundant 208V 30amp 3-phase 4 wire, NA
Redundant 380 - 415V 20A 3-phase 5 wire, Intl
Redundant -48VDC ± 10%

HP ProLiant BL p-Class Interconnect Switch Option
(Two switches per kit)
(Every HP BladeSystem p-Class server blade enclosure requires two interconnect switches OR two RJ-45 patch panels)

Provides up to a 32 to 1 server networking cable reduction per server enclosure depending on the mix of HP ProLiant BL20p, HP ProLiant BL20p G2, and HP ProLiant BL40p server blades. Each interconnect switch (two per enclosure) reduces up to sixteen internal server network (NICs) ports to six external ports (four on a modular rear mounting interconnect module and two on the switch front panel). This provides a total of twelve external ports per server blade enclosure. Only one to all twelve external ports may be used per server blade enclosure.

The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kit is for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) in a Cisco infrastructure. The CGESM supports the same HP ProLiant BL40p G2 Fibre Channel pass-through as the GbE2.
The Cisco Gigabit Ethernet Switch Module Interconnect kit includes one CGESM Interconnect Switch or one CGESM Interconnect Switch populated with two (2) RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules.
Quantity 2 Cisco Gigabit Ethernet Switch Module Interconnect kits provide two Interconnect Switches providing any combination of up to twelve (12) RJ-45 10/100/1000 T/TX/T or Fiber SX external ports per server blade enclosure.
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) and BL25p Fibre Channel pass-through.

  • The ProLiant BL p-Class F-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadSX Interconnect Modules that provide eight (8) LC 1000 SX and two (4) RJ-45 10/100/1000 T/TX/T external ports per server blade enclosure.
  • The ProLiant BL p-Class C-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadT2 Interconnect Modules that provide twelve (12) RJ-45 10/100/1000 T/TX/T external ports per server blade enclosure.
  • The optional ProLiant BL p-Class Storage Connectivity Kit (321745 -B21) is required for BL25p Fibre Channel pass-through when using either the CGESM, C-GbE2 or F-GbE2 Interconnect Kit.

Also included (per Interconnect Switch):

  • One (1) RS-232 DB-9 front panel out-of-band management port
  • Redundant crosslink ports connecting the two interconnect switches
  • Redundant power inputs and on-board redundant fans
  • Hot-plug and hot-remove with configuration retention and no need to cable/re-cable
  • Power ON, management, and per port status and speed LED indicators
  • Reset/power momentary push-button switch
  • HP ProLiant BL Interconnect Switch Management Utilities and User Documentation CD
  • Fully pre-configured for rapid deployment and immediate operation
  • ProLiant BL Interconnect Switch Management System and Utilities:

Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support, and more.


HP ProLiant BL p-Class RJ-45 patch panel

6U (10.5-inch), Plugs into BL p-Class 6U server blade enclosures
Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections
Supports Gigabit Ethernet network controllers. 16 RJ-45 connectors on the back of each BL p-Class 6U RJ-45 patch panel (32 RJ-45 connections per server blade enclosure).

(Two patch panels per kit)
(Every HP BladeSystem p-Class server blade enclosure requires two interconnect switches OR two RJ-45 patch panels)

Required Network Cabling

10Base-T

Categories 3, 4 or 5 UTP (100 meters)
EIA/TIA-568 100-ohm STP (100 meters)
 100Base-TX Category 5 UTP (100 meters)
EIA/TIA-568 100-ohm STP (100 meters)
 1000Base-TCategory 5 UTP (100 meters)
EIA/TIA-568 100-ohm STP (100 meters)
 1000Base-SX50/125 µm Multimode Fiber, 400 MHz/Km (500 meters)
50/125 µm Multimode Fiber, 500 MHz/Km (550 meters)
62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters)
62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters)
contents
 Overview      Standard Features (Server Blade)      Standard Features (Server Blade Enclosure and Interconnects)      Standard Features (Power System and Rack Information)      Standard Features      Models      Options      Memory      Technical Specifications line.gif (50 bytes)

Standard Features (Power System and Rack Information)

HP BladeSystem p-Class Power System and Rack information NOTE: To determine power configuration please refer to the ProLiant BL p-Class Overview and Planning Whitepaper and sizing tool, please see the following URL:
http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/20p/index.html

HP BladeSystem p-Class 3U Power Enclosure 3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Dual input single phase and three phase models available. HP BladeSystem 3U p-Class power enclosure provides external, shared hot-plug power. Each three-phase power enclosure houses up to six hot-plug power supplies each single-phase power enclosures hold up to four hot-plug power supplies to power the BL p-Class server blades and interconnects.
Please use the sizing utility to determine the power needed for each configuration. http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.

HP BladeSystem p-Class 1U Power Enclosure 1U (1.75-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Multi-input single phase or three phase operation.
HP BladeSystem p-Class 1U power enclosure provides external, hot-plug power. Each 1U power enclosure houses up to six hot-plug power supplies to power up to one server blade enclosure, fully populated with BL p-Class server blades and interconnects.
Please use the sizing utility to determine the power needed for each configuration
http://www.hp.com/go/bladesystem/powercalculator.
Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.

HP BladeSystem p-Class Power Distribution (only required with 3U power enclosures)

In the HP BladeSystem p-Class infrastructure, redundant -48 VDC power (from the power enclosures or facility DC power) is distributed from the power enclosures to the server blade enclosures through a bus bar system. Hinges attach the HP BladeSystem bus bars to the rails in a rack. The bus bars swing open from the center to enable easy rear access to the server blades and network cables. Power is distributed redundantly through independent A- and B-sided bus bars.
Three different power distribution solutions are available depending on the maximum number of server blade enclosures planned for the rack:

  • HP BladeSystem p-Class scalable bus bar
  • HP BladeSystem p-Class mini bus bar
  • HP BladeSystem p-Class power bus box

NOTE: To support a full 42U rack server blades (6 server blade enclosures), two mini bus bars are needed.


Required Power SourceTwo 30-amp redundant power feeds per power enclosure
 Connectors
 NEMA receptacles (NA/Japan)
 NA 1-phaseL6-30, 250v, 30A 3-wire
 NA 3-phase
L15-30, 250V, 30A, 4-wire
IEC 309 Pin & Sleeve connectors (International)
 Intl 1-phase250V, 32A, 3- pin (2 pole + ground)
 Intl 3-phase380-415V, 32A, 5--pin
(4 pole + ground)
Optimized for power cabling from bottom and network cabling from top
contents
 Overview      Standard Features (Server Blade)      Standard Features (Server Blade Enclosure and Interconnects)      Standard Features (Power System and Rack Information)      Standard Features      Models      Options      Memory      Technical Specifications line.gif (50 bytes)

Standard Features

ProLiant Essentials Foundation Pack Software for the ProLiant BL Server Blades

ProLiant Essentials Rapid Deployment Pack Rapid Deployment Pack (RDP) is an automated deployment and provisioning solution for all ProLiant servers. RDP includes the Altiris Deployment Solution and ProLiant Integration Module featuring ProLiant server pre-configured events for OS installation, and optimized software drivers, firmware and management agents. Every RDP CD includes 10-node trial licenses for evaluation purposes. RDP requires a license for each server deployed and are available for purchase with blade servers. For more information, visit http://www.hp.com/servers/rdp.
HP Systems Insight Manger HP Systems Insight Manager (HP SIM) help maximize system uptime and performance and reduce system maintenance costs by providing proactive notification of problems before those problems result in unplanned downtime or reduced productivity. HP SIM is easy to set up to work with the Insight Management Agents, integrated Light-Out and Remote Insight Light-Out Edition, and Version Control Agents to deliver robust fault, configuration, and asset management as well as remote administration. With HP Systems Insight Manager customers will also be able to take advantage of role-based security; the ability to manage ProLiant, Integrity, and HP9000 systems; and plug-ins for storage, client, printer, and power management as well as server rapid deployment, performance management, and workload management. For more details on HP Systems Insight Manager visit http://www.hp.com/go/hpsim.
Management Agents The Management Agents form the foundation for HP's Intelligent Manageability strategy. They provide direct, browser-based access to in-depth instrumentation built into HP servers, workstations, desktops, and portables, and send alerts to HP Systems Insight Manager and other enterprise management applications in case of subsystem or environmental failures. For additional information about the Management Agents and other management products from HP, please visit the management Web site at http://www.hp.com/servers/manage.
Subscriber's Choice Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides software and driver change notifications for ProLiant products. Sign up at http://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis.
ROMPaq, support software, and
configuration utilities
The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options, available in the RDP CD, SmartStart or downloadable from Software and Drivers download pages, linked from the SmartStart website at http://www.hp.com/go/support
Insight Diagnostics Online Edition The most advanced configuration analysis, reporting and troubleshooting utilities used by HP and at your fingertips, available in SmartStart.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials

Optional ProLiant Essentials Value Packs

Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs:

  • Intelligent Networking Pack - detects and analyzes network bottlenecks or broken network linkages and steers traffic to the optimum route based on network conditions.
  • Performance Management Pack - a performance management solution that identifies and explains hardware performance bottlenecks on ProLiant servers and attached options enabling users to better utilize their valuable resources
  • Virtual Machine Management Pack - provides central management and control of virtual machines from Microsoft and VMware. Integrated approach provides the ability to manage both physical and virtual resources from a single management console.
  • Vulnerability and Patch Management Pack - identifies and remediates software security vulnerabilities due to missing patches as well operating system configurations that can be exploited by viruses, worms, and other blended threats
  • Workload Management Pack - provides easier management of complex environments, improving overall server utilization and enabling Windows® 2000 customers for the first time to confidently deploy multiple applications on a single multiprocessor ProLiant Server.
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information.

SmartStart

SmartStart is a tool that simplifies single server setup, providing a rapid way to deploy reliable and consistent server configurations. SmartStart 7.00 and later can now deploy the HP ProLiant BL20P G3 and HP ProLiant BL40P server blades, using the I/O port with an attached USB CD-ROM device. To obtain a copy of SmartStart for your blade server, redeem the coupon that is included with your Blade server or order your copy from the SmartStart web site. For more information, please visit the SmartStart Web site at http://www.hp.com/servers/smartstart.
SmartStart version supported (minimum): SmartStart 6.20


OS Support

Microsoft® Windows 2000 Advanced Server
Red Hat Linux 8.0
Red Hat Enterprise Linux AS
SuSE Linux Enterprise Server 7
United Linux
Microsoft Windows Server 2003
VMware Virtualization Software

NOTE: For a complete and up-to-date listing of supported OSs and versions, please visit our OS Support Matrix at: http://www.hp.com/go/supportos.
NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant BL p-Class, please see: http://h18004.www1.hp.com/support/files/server/us/family/model/5342.html.
NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux Web site at: http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html.

NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html.


Intelligent Manageability

Integrated Lights-Out Advanced (iLO)

Virtual CD-ROM
Virtual Floppy *
Virtual Power Button Control
Dedicated LAN Connectivity
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) Security
IML and iLO Event Logging
Support for 12 user accounts with customizable access privileges

Automatic Server Recovery-2 (ASR-2)
Insight Manager 7
HP Systems Insight Manager
Redundant ROM
Remote Flash ROM
ROM Based Setup Utility (RBSU)
Advanced Configuration and Power Interface Specification Ready (ACPI)
Server Health Logs
HP Redundant Power Supply Utility
Pre-Failure Warranty (covers processors, as well as hard drives and memory)
HP Interconnect Switch Management System and Utilities (interconnect switch option)
Integrated Management Log (IML)
Dynamic sector repairing and drive parameter tracking (with Smart Array controllers)Redundant/adaptive load balancing NIC Support
* Advanced features such as Graphical Remote Console and Virtual Floppy are included with the BL p-Class server.


Availability

Power redundancy: Redundant AC feeds into power enclosures; redundant DC feeds from power enclosure to server blade enclosures, 1 + 1 redundant power supplies
Four hot-plug SCSI hard drive bays and integrated RAID (Smart Array 5i Plus Controller with 64-MB total Memory on the 5i Plus Memory Module) on every server blade. Battery Backed Write Cache Enabler Module standard on the 2 processor model and optional on the 1 processor model. Redundant ROM on each server blade
ECC Memory
Interconnects Switch Availability

  • Hot-plug and hot- remove with configuration retention and no need to cable/re-cable
  • Two network connections per server blade bay (four NICs total) routed to two redundant interconnect switches
  • Redundant inter-switch communication with two sets of redundant uplink ports per each interconnect switch
  • Redundant front panel ports per each interconnect switch for diagnostics, management, and additional uplinks
  • Redundant serial ports
  • Compatibility with PVST+ (CGESM or GbE2 switch) and 802.1D Spanning tree protocol support for loop-free path redundancy
  • Static IEEE 802.3ad (EtherChannel compatible) trunking with automatic port load balancing and failover
  • Redundant switch configuration images in memory (GbE2 switch)
  • Redundant fans per each interconnect switch
  • Redundant 1+1 power to each interconnect switch
  • Support for ProLiant network adapter teaming
  • Redundant configurable community strings and SNMP trap manager hosts
  • Redundant configurable syslog server, DNS server, and default gateways (GbE2 switch)

Security

Power-on password
Administrator's password
Integrated Lights-Out has 12 customizable user accounts and SSL encryption
Integrated Lights-Out can be disabled via a Global Setting
Interconnect switch multilevel user names and passwords, management interface time out period setting, SSH*, SCP secure copy protocol*, port-based IEEE 802.1Q tagged VLANs, RADIUS user authentication and authorization*, and IP address restriction
* CGESM and GbE2 Interconnect Switch only.


Minimum Rack Requirements

Mounts in HP Telco racks and Third Party racks that meet the following criteria:

  • Compatible with 19-inch Standard EIA rail sets
  • EIA rail-to-rail depth is 29 - 30"
  • Cabinet depth must be at least 36-inch deep overall (Additional min. 3.5-inch clearance from rear RETMA rail to rear door, inclusive in the 36-inch overall depth)
  • Ample room for top and bottom cable egress (approximately 8 square inches for full rack configuration with patch panel)
  • Must be capable of supporting 1600 lb (for full rack configuration)
  • Perforated front and rear doors to accommodate front-to-back cooling
  • Must have 65% open perforation on server blade enclosure doors to support airflow requirements
  • Optimized for use with the 10000 Series racks

NOTE: If using 7000 Series rack, Rack Extension Kit and High Air Flow Rack Door options are required.


Rack Airflow Requirements Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.

CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:

    • Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
    • Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm).

CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.

NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/40p/documentation.html.

Factory Express Portfolio for Servers and Storage HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed.

Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA3000 & EVA5000, XP, rackable tape libraries and configurable network switches.

For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express.


Service and Support Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of processors, memory and SCSI hard drives.) The warranty is fully supported by HP Services and a worldwide network of resellers and service providers. In addition 90-day's getting started software telephone support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services.
NOTE: Sever Blade Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.
NOTE: Server Blade Enclosure and Interconnects Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.

NOTE: SATA drives have a 1 year warranty.

Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical.

A full range of HP Care Pack hardware and software services are available including:

  • Installation and start up
  • Education courses
  • Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7 days call window with options including 4-hour response or 6-hour Call To Repair
  • Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and VMWare-based IT solutions helping to deliver high level of application availability. Response times range from 30 mins for critical problems to 2 hours.
  • System Management, Performance Services and Mission Critical Support Solution

HP Care Pack services for ProLiant BL p-Class server blades, cover the server blade and the p-Class blade enclosure that the server blade is installed in as well as interconnects, power enclosure with power supplies and power distribution.
NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or resellers or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack
NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at: http://www.hp.com/hps
NOTE: Additional information regarding worldwide limited warranty and technical support is available at:
http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html

contents
 Overview      Standard Features (Server Blade)      Standard Features (Server Blade Enclosure and Interconnects)      Standard Features (Power System and Rack Information)      Standard Features      Models      Options      Memory      Technical Specifications line.gif (50 bytes)

Models

ProLiant BL40p P3.0-4MB, 1GB (2P)
344286-B21
Processor(s) (2) Xeon MP 3.0 GHz standard (up to 4 supported)
Cache Memory 4-MB Level 3 Cache (per processor)
Memory 1024 MB (Standard) of 2-way interleaved PC2100 ECC DDR (2 X 512 MB)
Network Controller Five NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One additional 10/100T NIC dedicated to iLO Management
Storage Controller Smart Array 5i Plus Controller (integrated on system board) with BBWC
Hard Drives None ship standard
Internal Storage Up to 1200 GB maximum
Optical Drive None
Form Factor 6U high x 7" wide. Fits within p-Class Server Blade Enclosure

ProLiant BL40p P2.2-2MB, 512MB (1P)
345628-B21
Processor(s) (1) Xeon MP 2.2 GHz standard (up to 4 supported)
Cache Memory 2-MB Level 3 Cache (per processor)
Memory 512 MB (Standard) of 2-way interleaved PC2100 ECC DDR (2 X 256 MB)
Network Controller Five NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One additional 10/100T NIC dedicated to iLO Management
Storage Controller Smart Array 5i Plus Controller (integrated on system board)
Hard Drives None ship standard
Internal Storage Up to 1200 GB maximum
Optical Drive None
Form Factor 6U high x 7" wide. Fits within p-Class Server Blade Enclosure
contents
 Overview      Standard Features (Server Blade)      Standard Features (Server Blade Enclosure and Interconnects)      Standard Features (Power System and Rack Information)      Standard Features      Models      Options      Memory      Technical Specifications line.gif (50 bytes)

Options

HP ProLiant BL40p server blade Unique Options Xeon MP 3.0GHz 4MB Processor Option Kit 344287-B21
Xeon MP 2.2GHz 2MB Processor Option Kit 345627-B21
HP BladeSystem p-Class Diagnostic Station Upgrade Kit for the HP ProLiant BL40p server blade
309329-B21

ProLiant Essentials
Value Pack Software
ProLiant Essentials Intelligent Networking Pack  
ProLiant Essentials Intelligent Networking Pack, Single Server License
NOTE: For use with a single server. Contains one license with a unique license activation key and documentation.
372906-B21
NOTE: For additional ProLiant Intelligent Networking Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_div/11925_div.html
ProLiant Essentials Performance Management Pack
ProLiant Essentials Performance Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license activation key, HP Management CD and documentation.
NOTE: The most recent version of the software can always be downloaded at http://www.hp.com/products/pmp.

306696-B21
NOTE: For additional ProLiant Performance Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_div/11925_div.html
ProLiant Essentials Rapid Deployment Pack Windows Edition and Linux Edition Release
Rapid Deployment Pack, Single-Server License
NOTE: This license allows 1 server to be deployed and managed via RDP.
267196-B21
Rapid Deployment Pack, Single-Server License (Japan)
NOTE: This license allows 1 server to be deployed and managed via RDP.
267196-291
NOTE: For additional ProLiant Essentials Rapid Deployment Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html
http://h18000.www1.hp.com/products/quickspecs/11713_div/11713_div.html

ProLiant Essentials Server Migration Pack
ProLiant Essentials Server Migration Pack, Single-Migration License
NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation.
NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005.

375345-B21
NOTE: For additional ProLiant Server Migration Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12170_div/12170_div.html
ProLiant Essentials Workload Management Pack
ProLiant Essentials Workload Management Pack, Single Server License
303284-B21
NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_div/11452_div.html
ProLiant Essentials Workload Management Pack
ProLiant Essentials Workload Management Pack, Single Server License
303284-B21
NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_div/11452_div.html
ProLiant Essentials Virtual Machine Management Pack
ProLiant Essentials Virtual Machine Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license activation key and documentation.
372214-B21
NOTE: For additional ProLiant Virtual Machine Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12110_div/12110_div.html
ProLiant Essentials Vulnerability and Patch Management Pack
ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license activation key and documentation.
371645-B21
NOTE: For additional ProLiant Vulnerability and Patch Management Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_div/12111_div.html
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials.


Processor Xeon MP 3.0GHz 4MB Processor Option Kit 344287-B21
Xeon MP 2.2GHz 2MB Processor Option Kit 345627-B21

Memory (DDR DIMMs)512MB of PC2100 ECC DDR DIMM Memory Kit (2x256MB)
300678-B21
1024MB of PC2100 ECC DDR DIMM Memory Kit (2x512MB)
300679-B21
2048MB of PC2100 ECC DDR DIMM Memory Kit (2x1024MB)
300680-B21
4096MB of PC2100 ECC DDR DIMM Memory Kit (2x2048MB)
300682-B21

Hard Drives Wide Ultra320 – Universal Hot Plug
300-GB 10,000 rpm U320 Universal Hard Drive (1")
350964-B22
146.8-GB 10,000 rpm U320 Universal Hard Drive (1")
286716-B22
72.8-GB 10,000 rpm U320 Universal Hard Drive (1")
286714-B22
146.8-GB 15,000 rpm U320 Universal Hard Drive (1")
347708-B22
72.8-GB 15,000 rpm U320 Universal Hard Drive (1")
286778-B22
36.4-GB 15,000 rpm U320 Universal Hard Drive (1")
286776-B22
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds.  
NOTE: Please see the Hard Drive QuickSpecs for Technical Specifications such as capacity, height, width, interface, transfer rate, seek time, physical configuration, and operating temperature:
U320 Hard Drive QS:
http://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.html (Worldwide)
http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html (North America)
 

Storage Controllers Battery Backed Write Cache Enabler Option Kit
255514-B21
Battery Backed Write Cache Enabler Option Kit (Japan)
255514-291
Smart Array 6402/128 Controller
273915-B21
Smart Array 6404/256 Controller
273914-B21
Smart Array 642 Controller
291967-B21
256MB DDR, Battery-Backed Cache Upgrade Kit for SA-6400
NOTE: This 256-MB Battery-Backed Cache Module upgrade kit supports the Smart Array 6400 series controller only.
273913-B21
128MB Battery-Backed Cache Enabler
NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array 642 Controller.
 
NOTE: Please see the following Controller or SCSI Adapter QuickSpecs for Technical Specifications such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache, RAID support, and additional information:
http://h18000.www1.hp.com/products/quickspecs/11063_div/11063_div.html
(Smart Array 5i Plus)
http://h18000.www1.hp.com/products/quickspecs/11587_div/11587_div.html
(Smart Array 6400 Series)
http://h18000.www1.hp.com/products/quickspecs/12069_div/12069_div.html
(Smart Array 642)
 

Tape Libraries

HP StorageWorks MSL6000 Tape Library  
Ultrium 960 technology
MSL6030, 1 drive, 30 slots, Ultrium 960
AD606A
MSL6030, 2 drive, 30 slots, Ultrium 960
AD607A
MSL6030, 1 drive, 30 slots, Ultrium 960, with embedded FC router
AD608A
MSL6030, 2 drive, 30 slots, Ultrium 960, with embedded FC router
AD609A
MSL6060, 2 drive, 60 slots, Ultrium 960
AD610A
MSL6060, 2 drive, 60 slots, Ultrium 960, with embedded FC router
AD611A
SDLT 600 technology
MSL6026, 1 drive, 26 slots, SDLT 600
AD582A
MSL6026, 2 drive, 26 slots, SDLT 600
AD583A
MSL6026, 1 drive, 26 slots, SDLT 600, with embedded FC router
AD584A
MSL6026, 2 drive, 26 slots, SDLT 600, with embedded FC router
AD585A
MSL6052, 2 drive, 52 slots, SDLT 600
AD587A
MSL6052, 2 drive, 52 slots, SDLT 600, with embedded FC router
AD588A
Ultrium 460 technology
MSL6030, 1 drive, 30 slots, Ultrium 460
AD598A
MSL6030, 2 drive, 30 slots, Ultrium 460
AD599A
MSL6030, 1 drive, 30 slots, Ultrium 460, with embedded FC router
AD600A
MSL6030, 2 drive, 30 slots, Ultrium 460, with embedded FC router
AD601A
MSL6060, 2 drive, 60 slot Ultrium 460
AD603A
MSL6060, 2 drive, 60 slot Ultrium 460, with embedded FC router
AD604A
NOTE: Please reference the MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs.
HP StorageWorks MSL5026S2 Tape Library
MSL5026S2, 1 DRV, SDLT320, RM Library
293472-B22
MSL5026S2, 2 DRV, SDLT320, RM Library
293472-B23
MSL5026S2, 1 DRV, SDLT320, Fibre Channel, RM Library
293472-B24
MSL5026S2, 2 DRV, SDLT320, Fibre Channel, RM Library
293472-B25
NOTE: Please reference the MSL5026S2 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs.
HP StorageWorks MSL5052S2 Tape Library
 
MSL5052S2, 2 DRV, SDLT320, RM Library
293474-B21
MSL5052S2, 2 DRV, SDLT320, Fibre Channel, RM Library 293474-B24
NOTE: Please reference the MSL5052S2 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs
HP StorageWorks MSL5060 Tape Library  
MSL5060, 2 drive, 60 slots, Ultrium 230, RM with embedded FC router 301899-B22
MSL5060, 2 drive, 60 slots, Ultrium 230, TT 301899-B23
NOTE: Please reference the MSL5060 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs  
HP StorageWorks ESL E-Series Tape Libraries  
ESL Extended 712e Tape Library, 0 drive, 712 LTO slots AA934B
ESL Extended 630e Tape Library, 0 drive, 630 SDLT slots
AA935B
ESL Extended 322e Tape Library, 0 drive, 322 LTO slots
AA939B
ESL Extended 286e Tape Library, 0 drive, 286 SDLT slots
AA940B
ESL E-Series Ultrium 960 drive kit AD595A
ESL E Ultrium 460 drive kit
AA937A
ESL E Ultrium 460-FC drive kit AA941A
ESL E SDLT 320 drive kit AA936A
ESL E e2400-FC Interface Controller AA928A
NOTE: Please reference the ESL E-Series Tape Libraries QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs  

Magneto-Optical Jukeboxes

HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes
300mx, 2 drive, 32 slot jukebox C1150M
600mx, 4 drive, 64 slot jukebox C1160M
700mx, 2 drive, 76 slot jukebox C1170M
NOTE: Please reference the Magneto-Optical Jukebox data sheets at http://www.hp.com/go/optical for additional information needed to create a complete solution  
HP StorageWorks 9.1 GB High-end Optical Jukeboxes  
1200mx, 4 drive, up to 128 slots C1104M
1200mx, 6 drive, up to 128 slots C1105M
2200mx, 4 drive, up to 238 slots C1111M
2200mx, 6 drive, up to 238 slots C1107M
2200mx, 10 drive, up to 238 slots C1110M

HP BladeSystem p-Class Server Blade Enclosures HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components and the HP BladeSystem Management Suite
NOTE: Includes a HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components, a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM).
NOTE: The HP ProLiant BL40p server blade does not currently support (PMP). Future support is planned.

380625-B22
HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components (ProLiant Essentials Rapid Deployment Pack Trial)
243564-B22
HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components (8 ProLiant Essentials Rapid Deployment Licenses)
281404-B22
HP BladeSystem p-Class Server Blade Enclosure Upgrade Kit (option)
NOTE: Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support BL p-class blades and provide a single, physical iLO port for the enclosure.
354100-B21

HP BladeSystem p-Class Interconnects ProLiant BL p-Class RJ-45 Patch Panel 2 with Fibre Channel pass-through (pair) (required for ProLiant BL20p G2 Fibre Channel connectivity when using the RJ-45 Patch Panel 2)
NOTE: Only one interconnect kit required per server blade enclosure.
306465-B21
ProLiant BL p-Class RJ-45 Patch Panel (pair)
NOTE: Only one interconnect kit required per server blade enclosure.
230766-B21
ProLiant BL p-Class C-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadT2 Interconnect Modules)
NOTE: Only one interconnect kit required per server blade enclosure.
283192-B21
ProLiant BL p-Class F-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadSX Interconnect Modules)
NOTE: Only one interconnect kit required per server blade enclosure.
283193-B21
Cisco Gigabit Ethernet Switch Module