Overview
|
HP ProLiant BL20p Generation 2 (G2) Server Blade
|
| What's New |
|
|
|
| At A Glance |
|
| |
|
|
|
||||||||||||
|
|
||||||||||||||||||||||||||||
| Configuration Steps |
|
|
|
|
Standard Features (Server Blade)
| Processor | Intel Xeon processor 3.2 GHz/533 MHz - 2MB |
| Intel Xeon processor 3.2 GHz/533 MHz - 1MB | |
| Intel Xeon processor 3.06 GHz/533 MHz - 1MB | |
| Intel Xeon Processor 3.06 GHz/533 MHz - 512KB | |
| Intel Xeon Processor 2.8 GHz/533 MHz - 512KB | |
|
|
|
| Upgradeability | Upgradeable to dual processing |
|
|
|
| Cache
Memory One of the following depending on Model |
2-MB Level 3 Cache |
| 1-MB Level 3 Cache | |
| 512-KB Level 2 Cache | |
|
|
|
| Chipset | ServerWorks
GC-LE chipset NOTE: For more information regarding ServerWorks, please see the following URL: http://www.serverworks.com/products/overview.html. |
| | |
| Memory | Type | 2-way interleaved PC2100 DDR SDRAM running at 266MHz | |
| Standard | 1024 MB (depending on model) |
(2 x 512-MB | |
| Maximum | 8 GB | ||
| Standard | 512 MB, (depending on model) |
(2 x 256-MB) | |
| Maximum | 8 GB | ||
| NOTE: Memory must be installed in pairs. | |||
|
|
|||
| Network Adapter | Four network adapters total: |
| Three NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE | |
| One 10/100 iLO NIC dedicated to management | |
|
|
|
| Manageability | Integrated Lights-Out (iLO) Management Advanced (ASIC on the System Board) |
|
|
|
| Internal Storage | Hard Drives | None ship standard | |
| Maximum Internal Storage | SCSI | 293.6GB | (2 x 146.8 GB) |
|
|
|||
|
Fiber Channel on the
HP ProLiant BL20p G2 server blade |
The following items are needed to connect the HP ProLiant BL20p G2 server blade to the SAN: |
| 1. HP ProLiant BL 20p G2 server blade with Dual-port Fibre Channel Mezzanine Card installed | |
| |
| 2A. BL p-Class Patch Panel 2 (with Fibre Channel pass through) interconnect option | |
| |
| 2B. BL p-Class C-GbE2 or F-GbE2 Interconnect Kit plus the optional Storage Connectivity Kit | |
| |
| 3. Compatible SAN | |
| |
| | |
| Expansion Slots | No PCI slots all features are integrated |
| I/O cable connectors: | |
| (2)USB ports, (1) video port, (1) iLO port and (1) kernel debug port | |
| (2) I/O cables ship with every server blade enclosure | |
| Tested USB devices (keyboard, mouse, floppy) are listed in options section of this QuickSpecs |
|
|
Standard Features (Server Blade Enclosure and Interconnects)
| HP BladeSystem p-Class Server Blade Enclosure and Interconnects | |
| HP BladeSystem p-Class Server Blade Enclosure |
6U (10.5-inch), 19-inch wide |
| Holds up to 8 HP ProLiant BL20p G2 servers blades | |
|
10 bays per server blade enclosure 8 bays for server blades |
|
| 2 outside bays for interconnect modules (RJ-45 Patch Panel, RJ-45 Patch Panel 2, GbE Interconnect Switch, GbE2 or CGESM Interconnect Switch) | |
| Server blades blind mate into the server blade enclosure backplane for power and data connections | |
| Up to 6 BL p-Class 6U server blade enclosures fit in a 42U rack | |
| NOTE: Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support specific HP ProLiant BL20p G3 server blade models and provide a single, physical iLO port for the enclosure. | |
| Server blade management module attached to the back of each BL p-Class 6U server blade enclosure to report events all servers and provide asset and inventory information | |
|
|
|
| HP BladeSystem p-Class Power Requirements |
Redundant 200V - 240V AC, 30
amp single-phase Redundant 208V 30amp 3-phase 4 wire Redundant -48VDC ± 10% |
|
|
|
|
HP BladeSystem (Every HP BladeSystem p-Class server blade enclosure requires two interconnect
switches OR two RJ-45 patch panels) |
The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kit () are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) in a Cisco infrastructure. The CGESM supports the same and BL35p Fibre Channel pass-through as the GbE2.
The optional ProLiant BL p-Class Storage Connectivity Kit (321745 -B21)
is required for BL35p Fibre Channel pass-through when using the CGESM
Interconnect Kit. |
|
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) and BL25p Fibre Channel pass-through.
|
|
| The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet). | |
|
|
| Also included (per Interconnect Switch): | |
|
|
| ProLiant BL Interconnect Switch Management System and Utilities: | |
| Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing of speed and duplex mode, and more. | |
|
|
|
| ProLiant BL p-Class Storage
Connectivity Kit Option (supports two CGESM or GbE2 switches per kit) |
The Storage Connectivity Kit
is used if HP ProLiant BL20p G3 Fibre Channel signal pass-through is desired
when using the CGESM or GbE2 Interconnect Switch. Therefore, both LAN cable
consolidation and SAN connectivity is possible using a single interconnect
option. Order one Storage Connectivity Kit per server blade enclosure for
HP ProLiant BL20p G3 Fibre Channel pass through. The Storage Connectivity Kit includes two OctalFC Interconnect Modules that provide sixteen open transceiver slots for the pluggable small form factor transceivers that come with each HP ProLiant BL20p G3 Dual port Fibre Channel Adapter. The Storage Connectivity Kit supports up to eight HP ProLiant BL20p G3 server blades (for a total of sixteen Fibre Channel signals). |
|
|
|
| ProLiant
BL p-Class RJ-45 Patch Panel (Two patch panels per kit) (Every BL p-Class server blade enclosure requires two Interconnect switches OR two RJ-45 patch panels) |
6U (10.5-inch), Plugs into BL p-Class 6U server blade enclosures |
| Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections | |
| Supports Gigabit Ethernet network adapters | |
| 16 RJ-45 connectors on the back of each BL p-Class 6U RJ-45 Patch Panel (32 RJ-45 connections per server blade enclosure) | |
|
|
|
| ProLiant
BL p-Class RJ-45 Patch Panel 2 (with Fibre Channel pass through) (Two patch panels per kit) (Every BL p-Class server blade enclosure requires two Interconnect switches OR two RJ-45 patch panels) NOTE: The Patch Panel 2 or a Switch Interconnect Kit is required for SAN connectivity on the HP ProLiant BL20p G2 server blade | 6U (10.5-inch), Plugs into BL p-Class 6U server blade enclosures | |
| Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections also used to pass Fibre Channel signals for SAN connectivity | ||
| Supports Gigabit Ethernet network adapters | ||
| 16 RJ-45 connectors on the back of each RJ-45 patch panel 2 (32 RJ-45 connections per server blade enclosure) | ||
| Fibre
Channel, pass through |
Fibre Channel signals travel from a HP ProLiant BL20p G2 with a Dual-Port Fibre Channel Mezzanine Card through p-Class server blade enclosure backplane. The Fibre Channel signals are terminated through the RJ-45 Patch Panel 2 in the interconnect bays. To provide redundancy each server blade has two Fibre Channel signals and one Fibre Channel signal terminates through the right RJ-45 Patch Panel 2, one Fibre Channel signal travels terminates through the left RJ-45 Patch Panel 2. | |
| 8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the front of each RJ-45 patch panel 2 (16 Fibre Channel connections per server blade enclosure); for insertion of SPF transceivers included with the HP ProLiant BL20p G2 Dual-port Fibre Channel Mezzanine Card | ||
| | ||
| Required
Network Cabling | 10Base-T
| Categories 3, 4 or
5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) |
| 100Base-TX | Category
5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) | |
| 1000Base-T | Category
5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) | |
| 1000Base-SX | 50/125 µm Multimode Fiber,
400 MHz/Km (500 meters) 50/125 µm Multimode Fiber, 500 MHz/Km (550 meters) 62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters) 62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters) |
|
| NOTE:
For cabling information, refer to the Web site at: | ||
|
|
Standard Features (Power System and Rack Information)
|
HP BladeSystem |
NOTE: To determine power configuration please refer to the ProLiant BL p-Class Overview and Planning Whitepaper and sizing tool at http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/20p/index.html. |
|
|
|
| HP BladeSystem p-Class Power Enclosure |
3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Dual input single phase and three phase models available. |
|
HP BladeSystem p-Class 3U power enclosure provides external, shared hot-plug
power. Each three-phase power enclosure houses up to six hot-plug power
supplies each single-phase power enclosures hold up to four hot-plug power
supplies to power the BL p-Class server blades and interconnects |
|
| Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed. | |
|
|
|
| HP BladeSystem p-Class Power Distribution |
In the HP BladeSystem p-Class infrastructure, redundant -48 VDC power (from the power enclosures or facility DC power) is distributed from the power enclosures to the server blade enclosures through the bus bar system. Hinges attach the HP BladeSystem bus bars to the rails in a rack. The bus bars swing open from the center to enable easy rear access to the server blades and network cables. Power is distributed redundantly through independent A- and B-sided bus bars. | ||
|
Three different power distribution solutions are available depending on the maximum number of server blade enclosures planned for the rack: |
|||
|
|||
| NOTE: To support a full 42U rack of HP ProLiant BL20p server blades (6 server blade enclosures), two mini bus bars are needed. | |||
|
Power Enclosures Supported |
Server Blade Enclosures Supported |
Max. Rack Space Occupied | |
| Scalable Bus Bar | 1
or 2 | up
to 5 | 36U |
| Mini Bus Bar |
1 |
up to 3 |
21U |
| Power Bus Box | 1 |
1 |
9U |
| Required Power Source | Two 30amp redundant power feeds
per power enclosure Connectors NEMA receptacles NA 1-phase L6-30, 250v, 30A 3-wire NA 3-phase L15-30, 250V, 30A, 4-wire Optimized for power cabling from bottom and network cabling from top |
| For cabling information, refer to the Web site at http://welcome.hp.com/country/us/en/prodserv/servers.html. |
|
|
Standard Features
|
ProLiant Essentials Foundation Pack Software for the ProLiant BL Server |
|
|||||||
|
||||||||
|
||||||||
| NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials . | ||||||||
|
|
||||||||
| Optional ProLiant Essentials Value Packs |
Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs:
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. |
|
|
|
| SmartStart | SmartStart is a tool that simplifies
single server setup, providing a rapid way to deploy reliable and consistent
server configurations. SmartStart 7.00 and later can now deploy the HP ProLiant
BL20P G3 and HP ProLiant BL40P server blades, using the I/O port with an
attached USB CD-ROM device. To obtain a copy of SmartStart for your blade
server, redeem the coupon that is included with your Blade server or order
your copy from the SmartStart web site. For more information, please visit
the SmartStart Web site at http://www.hp.com/servers/smartstart. SmartStart version supported (minimum): SmartStart 6.20 |
|
|
|
| OS Support | Microsoft® Windows |
|
| |
| Intelligent Manageability |
Integrated Lights-Out Advanced (iLO) |
|
|
| Automatic Server Recovery-2
(ASR-2) Insight Manager 7 HP Systems Insight Manager Redundant ROM Remote Flash ROM ROM Based Setup Utility (RBSU) Advanced Configuration and Power Interface Specification Ready (ACPI) Server and Interconnect Switch Health Logs Redundant Power Supply Utility Pre-Failure Warranty (covers processors, as well as hard drives and memory) Interconnect Switch Management System and Utilities (Interconnect Switch option) Integrated Management Log (IML) Off-Line Backup Processor capability Dynamic sector repairing and drive parameter tracking (with Smart Array controllers) Network adapter teaming set-up utility |
|
| * Advanced features such as Graphical Remote Console and Virtual Floppy are included with the BL p-Class server. | |
|
|
|
| Availability |
Power redundancy: Redundant AC feeds into power enclosures, redundant
DC feeds from power enclosure to server blade enclosures, |
|
|
|
|
|
| Security | Power-on password Administrator's password Integrated Lights-Out has 12 customizable user accounts and SSL encryption Integrated Lights-Out can be disabled via a Global Setting Interconnect switch multilevel user names and passwords, management interface time out period setting, SSH*, SCP secure copy protocol*, port-based IEEE 802.1Q tagged VLANs, RADIUS user authentication and authorization*, and IP address restriction * GbE2 Interconnect Switch only |
|
|
|
| Minimum Rack Requirements | Mounts in ProLiant, and Telco racks and Third Party racks that meet the following criteria: |
|
|
| NOTE: If using Compaq 7000 Series rack, Rack Extension Kit and High Air Flow Rack Door options are required. | |
|
|
|
| Rack Airflow Requirements | Rack 10000 series Cabinets The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. |
| CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: | |
|
|
| CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. | |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://www.hp.com/servers/bl20p. |
|
|
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA3000 & EVA5000, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
|
|
|
| Service and Support |
Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and service providers. In addition 90-day's getting started software telephone support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services. |
| NOTE: Sever
Blade Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site
support. NOTE: Server Blade Enclosure and Interconnects Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support. |
|
| Care Pack services provide a
range of life cycle support options that let you choose the service levels
that meet your business requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including: |
|
HP Care Pack services for ProLiant BL p-Class server blades, cover the server blade and the p-Class blade enclosure that the server blade is installed in as well as interconnects, power enclosure with power supplies and power distribution. |
|
| NOTE: For more
information on HP Care Pack services, contact any of our worldwide sales
offices or resellers or visit our worldwide Web site on the internet at:
http://www.hp.com/hps/carepack NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at: http://www.hp.com/hps NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html |
|
|
Models
| ProLiant BL20p
G2 X3.2-2MB, 1GB (2P) 359031-B21 |
Processor(s) | (2) Intel Xeon 3.2 GHz standard (up to 2 supported) |
| Cache Memory | 2-MB Level 3 writeback per processor | |
| Memory | 1024-MB (Standard) to 8-GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 266MHz (2x512MB) | |
| Network Adapter | Three NC7781 PCI-X Gigabit NICs
(embedded) with WOL and PXE One additional 10/100T NIC dedicated to iLO Management |
|
| Storage Controller | Smart Array 5i Plus Controller (integrated on system board) | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 293.6-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into ProLiant BL p-Class Server Blade Enclosure | |
|
|
||
| ProLiant BL20p
G2 X3.2-2MB, 1GB (2P) with FC Mezz Card 359032-B21 |
Processor(s) | (2) Intel Xeon 3.2 GHz standard (up to 2 supported) |
| Cache Memory | 2-MB Level 3 writeback per processor | |
| Memory | 1024-MB (Standard) to 8-GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 266MHz (2x512MB) | |
| Network Adapter | Three NC7781 PCI-X Gigabit NICs
(embedded) with WOL and PXE One additional 10/100T NIC dedicated to iLO Management |
|
| Storage Controller | Smart Array 5i Plus Controller (integrated on system board) | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 293.6-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into ProLiant BL p-Class Server Blade Enclosure | |
| Dual Port Fibre Channel Card | Provides redundant SAN connection | |
|
|
||
| ProLiant
BL20p G2 X3.06-512KB, 512MB (1P) 323145-B22 |
Processor(s) | (1) Intel Xeon 3.06 GHz standard (up to 2 supported) |
| Cache Memory | 512-KB Level 2 writeback per processor | |
| Memory | 512-MB (Standard) to 8-GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 266MHz (2x256MB) | |
| Network Adapter | Three NC7781 PCI-X Gigabit NICs
(embedded) with WOL and PXE One additional 10/100 NIC dedicated to iLO Management |
|
| Storage Controller | Smart Array 5i Plus Controller (integrated on system board) | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 293.6-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into ProLiant BL p-Class Server Blade Enclosure | |
|
|
||
| ProLiant
BL20p G2 X3.06-512KB, 512MB (1P) with FC mezzanine 323146-B22 |
Processor(s) | (1) Intel Xeon 3.06 GHz standard (up to 2 supported) |
| Cache Memory | 512-KB Level 2 writeback per processor | |
| Memory | 512-MB (Standard) to 8-GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 266MHz (2x256MB) | |
| Network Adapter | Three NC7781 PCI-X Gigabit NICs
(embedded) with WOL and PXE One additional 10/100 NIC dedicated to iLO Management |
|
| Storage Controller | Smart Array 5i Plus Controller (integrated on system board) | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 293.6-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into ProLiant BL p-Class Server Blade Enclosure | |
| Dual Port Fibre Channel Card |
Provides redundant SAN connection | |
|
|
||
|
ProLiant BL20p G2 |
Processor(s) | (2) Intel Xeon 3.06 GHz standard (up to 2 supported) |
| Cache Memory | 512-KB Level 2 writeback per processor | |
| Memory | 1024-MB (Standard) to 8-GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 266MHz (2x512MB) | |
| Network Adapter | Three NC7781 PCI-X Gigabit NICs
(embedded) with WOL and PXE One additional 10/100 NIC dedicated to iLO Management |
|
| Storage Controller | Smart Array 5i Plus Controller (integrated on system board) | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 293.6-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into ProLiant BL p-Class Server Blade Enclosure | |
|
|
||
| ProLiant
BL20p G2 X3.06-512KB, 1GB (2P) with FC mezzanine 323148-B22 |
Processor(s) | (2) Intel Xeon 3.06 GHz standard (up to 2 supported) |
| Cache Memory | 512-KB Level 2 writeback per processor | |
| Memory | 1024-MB (Standard) to 8-GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 266MHz (2x512MB) | |
| Network Adapter | Three NC7781 PCI-X Gigabit NICs
(embedded) with WOL and PXE One additional 10/100 NIC dedicated to iLO Management |
|
| Storage Controller | Smart Array 5i Plus Controller (integrated on system board) | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 293.6-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into ProLiant BL p-Class Server Blade Enclosure | |
| Dual Port Fibre Channel Card |
Provides redundant SAN connection | |
|
|
||
|
ProLiant BL20p G2 Blades starter bundle/kit |
Blade Servers | Kit contains (2) HP ProLiant BL20pG2 server blades with two 3.06GHz Intel Xeon processors and 1GB of memory |
| Server Blade Enclosure | Kit contains 1 BL p-Class Server Blade Enclosure with 8 Rapid Deployment Pack licenses | |
| Interconnect | Kit contains BL p-Class RJ-45 Patch Panel's (comes in pairs) | |
| Power Subsystem | Kit contains 1 BL p-Class Single Phase Redundant Power Enclosure with 2 power supplies and a Mini Bus Bar | |
|
|
||
|
ProLiant BL20p G2 Blades starter bundle/kit - High
Performance Model |
Blade Servers | Kit contains (2) HP ProLiant BL20pG2 server blades with two 3.2GHz Intel Xeon processors, 1GB of memory, and Fibre Channel mezzanine adapter. |
| Server Blade Enclosure | Kit contains 1 BL p-Class Server Blade Enclosure with 8 Rapid Deployment Pack licenses | |
| Interconnect | Kit contains BL p-Class RJ-45 Patch Panel 2 with Fibre Channel pass through (comes in pairs) | |
| Power Subsystem | Kit contains 1 BL p-Class Single Phase Redundant Power Enclosure with 2 power supplies and a Mini Bus Bar |
|
|
Options
| ProLiant
Essentials Value Pack Software |
ProLiant Essentials Vulnerability and Patch Management Pack, 1 - Server + 10 Desktop Bundle License |
389941-B21
|
| ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License |
371645-B21
|
|
| ProLiant Essentials
Vulnerability and Patch Management Pack, 10 - Server License |
372029-B21
|
|
| ProLiant Essentials
Vulnerability and Patch Management Pack, Flexible-Quantity License |
371646-B21
|
|
| ProLiant Essentials
Vulnerability and Patch Management Pack, Tracking license for new servers |
371647-B21
|
|
| ProLiant Essentials
Vulnerability and Patch Management Pack, Tracking license for installed
servers |
378372-B21
|
|
| ProLiant Essentials Server Migration Pack, 25 - Server License |
391674-B21
|
|
| ProLiant Essentials Server Migration Pack, 50 - Server License |
391675-B21
|
|
| ProLiant Essentials Server Migration Pack, 100 - Server License |
391676-B21
|
|
| ProLiant Essentials
Server Migration Pack, 10 - Server License Note: This license allows 10 servers to be migrated from a physical server to 10 virtual machines. Or this license can be used to migrate 10 virtual machines from one virtualization layer i.e. VMware ESX or Microsoft Virtual Server 2005. |
390739-B21
|
|
| ProLiant Essentials Server Migration Pack, Single-Server License |
375345-B21
|
|
| ProLiant Essentials Server Migration Pack, Flexible-Quantity License |
375346-B21
|
|
| ProLiant Essentials Server Migration Pack, Tracking license |
375347-B21
|
|
| ProLiant Essentials
Virtual Machine Management Pack, SINGLE LIC IP CCAO-WGR |
372214-B21
|
|
| ProLiant Essentials
Virtual Machine Management Pack, FLEX LIC IP CCAO-WGR |
372215-B21
|
|
| ProLiant Essentials Virtual Machine Management Pack, TRACKING LIC IP CCAO-WGR |
372216-B21
|
|
| ProLiant Essentials
Performance Management Pack, 10 - Server License NOTE: For use with up to 10 servers. Contains 10 licenses with one unique license activation key and documentation. |
374055-B21
|
|
| Performance Management
Pack, single server NOTE: This license allows 1 server to be managed by Performance Management Pack. |
306696-B21
|
|
| Performance Management
Pack, flexible license kit NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials |
306697-B21
|
|
| Rapid Deployment Pack, 10 User, V1.x |
269817-B21 |
|
| NOTE:
This license allows 10 servers to be managed and deployed via the Deployment
Server. NOTE: Not necessary if you purchase the server blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21. NOTE: Rapid Deployment pack is now available in Linux only environments. |
||
| Rapid Deployment Pack, 1 User, V1.x |
267196-B21
|
|
| NOTE:
This license allows 1 servers to be managed and deployed via the Deployment
Server. NOTE: Not necessary if you purchase the server blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21. NOTE: Rapid Deployment pack is now available in Linux only environments. |
||
| Flexible Quantity License Kit |
302127-B21
|
|
| License-Only - for use with a Master License Agreement |
302128-B21
|
|
| ProLiant Essentials
Intelligent Networking Pack, Single Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372906-B21
|
|
| ProLiant Essentials
Intelligent Networking Pack, Flexible License NOTE: For use with multiple servers. This part number can be used to purchase multiple licenses with a single activation key. The quantity ordered for this part number will be the quantity of licenses included in the kit in the form of a corresponding activation key. Use the same key to activate all licenses in the actual quantity ordered. For a given order, one kit will be delivered with the activation key, and documentation. |
372950-B21
|
|
| ProLiant Essentials
Intelligent Networking Pack, Tracking License NOTE: For use with signed and implemented Activation Key Agreements only. Purchase of this part number entitles the customer to deploy additional licenses of the product under the terms of the existing Activation Key Agreement. NOTE: Nothing is delivered in conjunction with the purchase of this part number. Visit http://h18004.www1.hp.com/products/servers/proliantessentials/license/akalic.html for more information on Activation Key Agreements. |
372951-B21
|
|
| ProLiant Essentials Workload Management Pack (Featuring Resource Partitioning Manager version 2.0) |
303284-B21
|
|
| NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://hp.com/servers/proliantessentials. | ||
| NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to URL http://hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. | ||
|
|
||
| Processor | Intel Xeon 2.80 GHz-1M Processor Option Kit |
359559-B21
|
| Intel Xeon 3.06 GHz-512KB Processor Option Kit |
323247-B21 |
|
| Intel Xeon 2.80 GHz-512KB Processor Option Kit |
300873-B21
|
|
| NOTE: There is no option kit offered for the Intel Xeon 3.2GHz-1MB or 3.06 GHz-1MB Processor because all models ship with two processors. | ||
|
|
||
|
Memory |
4096MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 2 GB) |
300682-B21
|
| 2048MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 1 GB) |
300680-B21
|
|
| 1024MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 512 MB) |
300679-B21
|
|
| 512MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 256 MB) |
300678-B21
|
|
|
|
||
| Hard Drives | Ultra 320 SCSI – Universal Hot Plug | |
| 146.8-GB 10,000 rpm U320 Universal Hard Drive (1") |
286716-B22
|
|
| 72.8-GB 10,000 rpm U320 Universal Hard Drive (1") |
286714-B22
|
|
| 300-GB 10,000 rpm U320 Universal Hard Drive (1") |
350964-B22
|
|
| 146.8-GB 15,000 rpm U320 Universal Hard Drive (1") |
347708-B22
|
|
| 72.8-GB 15,000 rpm U320 Universal Hard Drive (1") |
286778-B22
|
|
| 36.4-GB 15,000 rpm U320 Universal Hard Drive (1") |
286776-B22
|
|
|
|
||
| SAN Switches | Brocade 4GB SAN Switch, Base |
A7533A
|
| Brocade 4GB SAN Switch, full fabric |
A7534A
|
|
| Brocade
4GB SAN Switch, power pack |
A7535A
|
|
|
|
||
| Storage Controllers | Battery Backed Write Cache Enabler Option Kit |
255514-B21 |
| NOTE: Please see
the following Controller QuickSpecs for Technical Specifications such as
PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak
Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache, RAID
support, and additional information: http://h18000.www1.hp.com/products/quickspecs/11063_na/11063_na.html (Smart Array 5i Plus) |
||
|
|
||
| ProLiant BL20p G2 - Fibre Channel Mezzanine Card | Dual port Fibre Channel Mezzanine Card (2-Gb) for ProLiant BL20p G2 |
300874-B21 |
| NOTE: When using
this card, the Patch Panel 2 or a GbE2 Interconnect Switch (with Connectivity
Kit) must be used to provide the Fibre Channel pass through. |
||
|
|
||
| HP BladeSystem p-Class Server Blade Enclosures |
HP BladeSystem p-Class Server
Blade Enclosure with the HP BladeSystem Management Suite NOTE: Includes a HP BladeSystem p-Class Server Blade Enclosure, a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM). |
380625-B22
|
| HP BladeSystem p-Class Server Blade Enclosure (ProLiant Essentials Rapid Deployment Pack Trial) |
243564-B21 |
|
| HP BladeSystem p-Class Server Blade Enclosure (8 ProLiant Essentials Rapid Deployment Pack Licenses) |
281404-B21
|
|
| HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components (ProLiant Essentials Rapid Deployment Pack Trial) |
243564-B22
|
|
| HP BladeSystem p-Class Server
Blade Enclosure with enhanced backplane components (8 ProLiant Essentials
Rapid Deployment Licenses) NOTE: HP BladeSystem p-Class Enhanced Server Blade Enclosures may be required depending on which HP ProLiant BL20pG3 server blade model is selected. |
281404-B22
|
|
| HP BladeSystem p-Class Server
Blade Enclosure Upgrade Kit (option) NOTE: Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support BL p-class blades and provide a single, physical iLO port for the enclosure. |
354100-B21
|
|
|
|
||
| HP
BladeSystem p-Class Interconnects |
ProLiant BL p-Class RJ-45 Patch Panel 2 with Fibre pass-through (pair) (required for FC connectivity) |
306465-B21 |
| NOTE: Only one interconnect kit required per server blade enclosure. | ||
| ProLiant BL p-Class RJ-45 Patch Panel (pair) |
230766-B21
|
|
| NOTE: Only one interconnect kit required per server blade enclosure. | ||
| Cisco Gigabit Ethernet
Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit only NOTE: Two CGESM interconnect kits required per server blade enclosure. |
378926-B21
|
|
| Cisco Gigabit Ethernet
Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit (populated
with two RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules. NOTE: Two CGESM interconnect kits required per server blade enclosure. |
378927-B21
|
|
| Cisco RJ-45 10/100/1000 T/TX/T SFP Module |
378928-B21
|
|
| Cisco Fiber SX SFP Module |
378929-B21
|
|
| ProLiant BL p-Class C-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadT2 Interconnect Modules) |
283192-B21
|
|
| NOTE: Only one interconnect kit required per server blade enclosure. | ||
| ProLiant BL p-Class F-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadSX Interconnect Modules) |
283193-B21
|
|
| NOTE: Only one interconnect kit required per server blade enclosure. | ||
| ProLiant BL p-Class Storage Connectivity Kit (with pair of OctalFC Interconnect Modules and two Fibre Channel signal conditioning cards) |
321745 -B21
|
|
| NOTE:
Required for HP ProLiant BL20P G2 Fibre Channel signal pass through when
using the GbE2 Interconnect Switch. NOTE: Only one Storage Connectivity Kit required per each GbE2 Interconnect Kit. |
||
| ProLiant BL p-Class C-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two QuadT Interconnect Modules) |
249655-B21
|
|
| NOTE:
Only one interconnect kit required per server blade enclosure. NOTE: The GbE Interconnect Switch supports server NIC speeds to 100 Mbps. It is recommended that a patch panel or GbE2 Interconnect Switch option be used if server NIC speeds to 1000 Mbps are required. NOTE: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit. |
||
| ProLiant BL p-Class F-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two DualTSX Interconnect Modules) |
279720-B21
|
|
| NOTE:
Only one interconnect kit required per server blade enclosure. NOTE: The GbE Interconnect Switch supports server NIC speeds to 100 Mbps. It is recommended that a patch panel option be used if server NIC speeds to 1000 Mbps are required. NOTE: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit. |
||
|
|
||
| BL p-Class Power Options | NOTE:
Use p-Class sizing tool to help determine power configuration: http://h30099.www3.hp.com/configurator/powercalcs.asp |
|
| Single Phase Power
Enclosure with 4 power supplies (Single Phase Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit) |
239162-001
|
|
| 3 Phase Power Enclosure
with 6 power supplies (3 Phase Power Enclosure holds a maximum of 6 power supplies; no need to order additional power supplies with this option kit) |
230769-001
|
|
| Single Phase Power
Enclosure (empty) (Holds up to 4 power supplies; power supplies are not included in this kit) |
231710-001
|
|
| 3 Phase Power Enclosure
(empty) (Holds up to 6 power supplies; power supplies are not included in this kit) |
231709-001
|
|
| Single 3U Power Supply |
239161-B21
|
|
| 1U Power Enclosure with six power supplies |
378284-B21
|
|
| 1U Power Enclosure with two power supplies |
380314-B21
|
|
| Single 1U power supply |
380312-B21
|
|
| Facility DC Power Connection |
240563-B21
|
|
|
|
||
| Power Distribution (only required with 3U power enclosure) | ProLiant p-Class Scalable Bus Bar |
240560-B21
|
| ProLiant p-Class Mini Bus Bar |
240559-B21
|
|
| ProLiant p-Class Bus Power Box |
240562-B21
|
|
| HP Modular Distribution Unit 40 Amp* |
252663-D75
|
|
| HP Modular Distribution Unit 24
Amp* *NOTE: The Modular Distribution Unit Kits excludes the extension bars as they are not required with the HP BladeSystem p-class 1U power enclosure. |
252663-D74
|
|
| HP BladeSystem Power Extension
Kit NOTE: This kit is specifically for HP BladeSystem p-Class customers who want to upgrade their standard server blade enclosures to enhanced server blade enclosures and would like to install an additional, redundant 3U power enclosure above the server blade enclosures rather than below them. The option kit consists of two extension cable assemblies - one for each side (A and B). |
381686-B21
|
|
|
|
||
| Other Options |
ProLiant p-Class Diagnostic Station |
230743-B21 |
|
ProLiant BL p-Class Server Enclosure Shipping Bracket Option Kit |
293121-B21 |
|
| ProLiant BL p-Class Power Enclosure
Shipping Bracket Option Kit NOTE: Used to secure one power enclosure in a rack when moving. |
365044-B21
|
|
|
|
||
|
Tape Libraries |
HP StorageWorks MSL6000 Tape Library | |
| Ultrium 960 technology | ||
| MSL6030, 1 drive, 30 slots, Ultrium 960 | AD606A | |
| MSL6030, 2 drive, 30 slots, Ultrium 960 | AD607A | |
| MSL6030, 1 drive, 30 slots, Ultrium 960, with embedded FC router | AD608A | |
| MSL6030, 2 drive, 30 slots, Ultrium 960, with embedded FC router | AD609A | |
| MSL6060, 2 drive, 60 slots, Ultrium 960 | AD610A | |
| MSL6060, 2 drive, 60 slots, Ultrium 960, with embedded FC router | AD611A | |
| SDLT 600 technology | ||
| MSL6026, 1 drive, 26 slots, SDLT 600 | AD582A | |
| MSL6026, 2 drive, 26 slots, SDLT 600 | AD583A | |
| MSL6026, 1 drive, 26 slots, SDLT 600, with embedded FC router | AD584A | |
| MSL6026, 2 drive, 26 slots, SDLT 600, with embedded FC router | AD585A | |
| MSL6052, 2 drive, 52 slots, SDLT 600 | AD587A | |
| MSL6052, 2 drive, 52 slots, SDLT 600, with embedded FC router | AD588A | |
| Ultrium 460 technology | ||
| MSL6030, 1 drive, 30 slots, Ultrium 460 | AD598A | |
| MSL6030, 2 drive, 30 slots, Ultrium 460 | AD599A | |
| MSL6030, 1 drive, 30 slots, Ultrium 460, with embedded FC router | AD600A | |
| MSL6030, 2 drive, 30 slots, Ultrium 460, with embedded FC router | AD601A | |
| MSL6060, 2 drive, 60 slot Ultrium 460, with embedded FC router | AD604A | |
| NOTE: Please reference the MSL6000 Tape Library QuickSpecs at www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at www.hp.com/go/ebs. | ||
| HP StorageWorks MSL5026S2 Tape Library | ||
| MSL5026S2, 1 drive, 26 slots, SDLT 320, RM | ||
| MSL5026S2, 2 drive, 26 slots, SDLT 320, RM | ||
| MSL5026S2, 1 drive, 26 slots, SDLT 320, RM with embedded FC router | ||
| MSL5026S2, 2 drive, 26 slots, SDLT 320, RM with embedded FC router | ||
| NOTE: Please reference the MSL5026S2 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. | ||
| HP StorageWorks MSL5052S2 Tape Library | ||
| MSL5052S2, 2 drive, 52 slots, SDLT 320, RM | 293474-B21 | |
| MSL5052S2, 2 drive, 52 slots, SDLT 320, RM with embedded FC router | 293474-B24 | |
| MSL5052S2, 2 drive, 52 slots, SDLT 320, TT | 293476-B21 | |
| NOTE: Please reference the MSL5052S2 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http:/www.hp.com/go/ebs | ||
| HP StorageWorks MSL5060 Tape Library | ||
| MSL5060, 2 drive, 60 slots, Ultrium 230, RM | 301899-B22 | |
| MSL5060, 2 drive, 60 slots, Ultrium 230, RM with embedded FC router | 301899-B23 | |
| MSL5060, 2 drive, 60 slots, Ultrium 230, TT | 301900-B21 | |
| NOTE: Please reference the MSL5060 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs | ||
| HP StorageWorks ESL E-Series
Tape Libraries |
||
| ESL Extended 712e Tape Library,
0 drive, 712 LTO slots |
AA934B | |
| ESL Extended 630e Tape Library,
0 drive, 630 SDLT slots |
AA935B | |
| ESL Extended 322e Tape Library,
0 drive, 322 LTO slots |
AA939B | |
| ESL Extended 286e Tape Library,
0 drive, 286 SDLT slots |
AA940B | |
| ESL E-Series Ultrium 960 drive kit | AD595A | |
| ESL E Ultrium 460 drive kit |
AA937A | |
| ESL E SDLT 320 drive kit |
AA936A | |
| ESL E e2400-FC 2G Interface Controller | AA928A | |
| NOTE: Please reference the ESL E-Series Tape Libraries QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. | ||
|
|
||
|
Magneto-Optical Jukeboxes |
HP StorageWorks 9.1 GB Mid-range
Optical Jukeboxes |
|
| 300mx, 2 drive, 32 slot jukebox | C1150M | |
| 600mx, 4 drive, 64 slot jukebox | C1160M | |
| 700mx, 2 drive, 76 slot jukebox | C1170M | |
| NOTE: Please reference the Magneto-Optical Jukebox data sheets at http://www.hp.com/go/optical for additional information needed to create a complete solution | ||
| HP StorageWorks 9.1 GB High-end Optical Jukeboxes | ||
| 1200mx, 4 drive, up to 128 slots | C1104M | |
| 1200mx, 6 drive, up to 128 slots | C1105M | |
| 2200mx, 4 drive, up to 238 slots | C1111M | |
| 2200mx, 6 drive, up to 238 slots | C1107M | |
| 2200mx, 10 drive, up to 238 slots | C1110M | |
|
|
||
| HP StorageWorks Modular Smart Array 1000 | HP StorageWorks Modular Smart Array 1000 | 201723-B22 |
| Modular Smart Array 1000 Controller | 218231-B22 | |
| Modular Smart Array Fibre Channel I/O Module | 218960-B21 | |
| Modular Smart Array hub 2/3 | 286763-B21 | |
| NOTE:
Please see the StorageWorks Modular Smart Array 1000 QuickSpecs for additional
options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html |
||
|
|
||
| Cluster Options | ProLiant Cluster HA/F200 for the Entry Level SAN |
364026-B21 |
| NOTE:
For additional information regarding the ProLiant Cluster for HA/F100,
HA/F200 for Modular Smart Array 1000 please see the following QuickSpecs
at: http://h18000.www1.hp.com/products/quickspecs/11035_na/11035_na.html |
||
| ProLiant Cluster Starter Kit |
364023-B21
|
|
| ProLiant Cluster Kit with OpenView Storage Mirroring |
364025-B21
|
|
| NOTE:
For additional information regarding the HP ProLiant Cluster for ProLiant
Cluster HA/F500 for Enterprise Virtual Array please see the following QuickSpecs
at: http://h18000.www1.hp.com/products/quickspecs/11055_na/11055_na.html |
||
| ProLiant Cluster F500 for the
Enterprise SAN |
364024-B21
|
|
| NOTE:
For additional information regarding the HP ProLiant Cluster for HA/F500
please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/10232_na/10232_na.html |
||
| HP Serviceguard for Linux ProLiant Cluster A.11.15 for SUSE SLES 8 / UnitedLinux 1.0 and Red Hat EL 3 (2 node license cluster kit). | 305199-B24 | |
| NOTE: Kit includes 2 licenses, documentation and an Ethernet crossover cable. | ||
| HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 and Red Hat EL 3 (2 node license cluster kit) | 305199-B25 | |
| HP Serviceguard for Linux License A.11.15 for SUSE SLES 8 / UnitedLinux 1.0 and Red Hat EL 3 (single license version) | 307754-B24 | |
| NOTE: Kit includes single license version and documentation. | ||
| HP Serviceguard for Linux A.11.16 for SUSE SLES9 and Red Hat EL 3 (single license version) | 307754-B25 | |
| NOTE: For additional
information regarding the HP Serviceguard for Linux License, please see
the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html |
||
|
|
||
| USB Options | USB 1.44-MB External Diskette Drive (Carbonite) |
DC141B
|
| USB Optical Scroll Mouse (Carbonite) | DD441B | |
| 256MB HP Drive Key II (USB 2.0) | PH657A | |
|
|
||
| HP Rack 5000 Series | HP 5642 Rack - Unassembled |
358254-B21
|
|
|
||
| Rack Options for Rack 5000 Series |
Stabilizer Kit for 5642 Rack (Graphite
Carbon) NOTE: The stabilizing kit is used to prevent rack from tipping over. |
374493-B21
|
| Baying Kit for 5642 Rack (Graphite
Carbon) NOTE: The baying kit is used to join two or more HP 5642 racks. |
374499-B21
|
|
|
|
||
|
Rack 10000 Series |
Rack, HP Infrastructure 42U (HV) |
379005-001
|
| Rack, HP Infrastructure 42U (LV) |
379006-001
|
|
| HP Rack 10842 (42U) - Pallet |
257415-B21
|
|
| HP Rack 10842 (42U) - Shock Pallet |
257415-B22
|
|
| HP S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22
|
|
|
HP Rack 10647 (47U) Cabinet - Pallet |
245160-B21 |
|
|
HP Rack 10647 (47U) Cabinet - Crated |
245160-B23 |
|
|
HP Rack 10642 (42U) Cabinet - Pallet |
245161-B21 |
|
|
HP Rack 10642 (42U) Cabinet - Shock Pallet |
245161-B22 |
|
|
HP Rack 10642 (42U) Cabinet - Crated |
245161-B23 |
|
|
HP Rack 10636 (36U) Cabinet - Pallet |
245162-B21 |
|
|
HP Rack 10636 (36U) Cabinet - Shock Pallet |
245162-B22 |
|
|
HP Rack 10636 (36U) Cabinet - Crate |
245162-B23 |
|
|
HP Rack 10622 (22U) Cabinet - Pallet |
245163-B21 |
|
|
HP Rack 10622 (22U) Cabinet - Shock Pallet |
245163-B22 |
|
|
HP Rack 10622 (22U) Cabinet - Crated |
245163-B23 |
|
| NOTE: -B21 (pallet)
used to ship empty racks shipped on a truck -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels) -B23 (crated) used for air shipments of empty racks Not all HP equipment is qualified to be shipped in the Rack 10000 series. |
||
| NOTE: Please see
the Rack 10000 QuickSpecs for Technical Specifications such as height, width,
depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html |
||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html | ||
|
|
||
|
Rack Options for HP |
HP Rack Plinth Kit (Carbon) |
251960-B21
|
| HP Rack Light Kit (Neon) |
361589-B21
|
|
|
42U Side Panel – Graphite Metallic |
246099-B21 |
|
|
36U Side Panel – Graphite Metallic |
246102-B21 |
|
|
47U Side Panel – Graphite Metallic |
255486-B21 |
|
| NOTE: For additional information regarding Rack Options, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. | ||
| TFT7210R Rack Mounted 17" Monitor 348373-B21 |
348373-B21
|
|
|
TFT5600 Rack Keyboard Monitor |
221546-001 |
|
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-ptions/index.html. | ||
| NOTE:
For a complete list of Monitors please view the following URL: http://h18004.www1.hp.com/products/monitors/ |
||
| 1U Rack Keyboard & Drawer
(Carbon) |
257054-001
|
|
| NOTE: For additional information regarding Rack Options, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. | ||
|
|
||
| HP KVM Switch Options | IP Console Switch Box (KVM/IP), 1 x 1 x 16 |
262585-B21
|
| IP Console Switch Box (KVM/IP), 3 x 1 x 16 |
262586-B21
|
|
| CAT5 KVM USB Interface Adapter |
336047-B21
|
|
| CAT5 KVM Serial Interface Adapter |
373035-B21
|
|
| CAT5e Cable 3', 4 pack |
263474-B21
|
|
| CAT5e Cable 6', 8 pack |
263474-B22
|
|
| CAT5e Cable 12', 8 pack |
263474-B23
|
|
| CAT5e Cable 20', 4 pack |
263474-B24
|
|
| CAT5e Cable 40', 1 pack |
263474-B25
|
|
| NOTE:
For additional information regarding HP KVM Switches and options, please
see the following URL: http://h18004.www1.hp.com/products/servers/proliantstorage/rack-options/list.html#console |
||
|
|
||
| Rack Options for Telco Racks | ProLiant BL p-Class Bus Bar Telco Rack Kit |
245249-B21
|
| ProLiant BL p-Class Enclosure Telco Rack Kit |
266076-B21
|
|
|
|
||
|
Service and Support Offerings (HP Care Pack Services) |
|
|||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||
|
|
Memory
|
HP ProLiant BL20p G2 Server Blade (2P Model) |
| Standard
Memory |
|
Memory |
Slot |
||||
|
1 |
2 |
3 |
4 |
||
|
Standard |
1024 MB |
512 MB |
512 MB |
Empty |
Empty |
| Optional |
5120 MB |
512 MB |
512 MB |
2048 MB |
2048 MB |
| Maximum | 8192 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
Following are memory options available from HP: |
|
|
300682-B21 |
|
300680-B21 |
|
300679-B21 |
|
300678-B21 |
| HP ProLiant BL20p G2 Server Blade (1P Model) |
| Standard
Memory 512-MB PC2100 MHz Registered DDR SDRAM DIMM installed (2 x 256-MB SDRAM DIMM) Standard Memory Plus Optional Memory Up to 4608-MB of DDR SDRAM DIMM memory is available with the installation of optional DDR SDRAM DIMM memory expansion kits. Standard Memory Replaced with Optional Memory Up to 8192-MB of DDR SDRAM DIMM memory is available with the removal of standard memory and the installation of optional DDR SDRAM DIMM memory expansion kits. |
|
Memory |
Slot |
||||
|
1 |
2 |
3 |
4 |
||
|
Standard |
512 MB |
256 MB |
256 MB |
Empty |
Empty |
| Optional |
4608 MB |
256 MB |
256 MB |
2048 MB |
2048 MB |
| Maximum | 8192 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
Following are memory options available from HP: |
|
|
300682-B21 |
|
300680-B21 |
|
300679-B21 |
|
300678-B21 |
|
|
Technical Specifications
| HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components |
Dimensions |
Height |
10.5 in (26.67 cm) |
|
| Width |
17.60 in (44.70 cm) |
|||
| Depth |
28.86 in (73.30 cm) |
|||
|
Input Specifications |
Rated input voltage |
-43 VDC to -53 VDC |
Nominal -48 VDC | |
| Rated input current | 125 A at -48 VDC | |||
|
Rated input Power |
6000 W |
|||
|
Individual Server Blade |
Rated input voltage | -43 VDC to -53 VDC | Nominal -48 VDC | |
| Rated input current | 14.6 A at -48 VDC | |||
| Rated input Power | 700 W | |||
|
Temperature Range |
Operating | 50° to 95° F (10° to 35° C) | ||
| Non-Operating | -22° to 140° F (-30° to 60° C) | |||
|
Relative Humidity |
Operating | 20% to 80% | ||
| Non-Operating | 5% to 95% | |||
|
Wet Bulb Temperature |
Operating | 82.4° F (28° C) | ||
| Non-Operating | 101.7° F (38.7° C) | |||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | ||||
|
|
||||
| Operating and Performance Specifications for RJ-45 Patch Panel 2 with Fiber Channel pass through |
Dimensions | Height |
10.405 in (26.43 cm) |
| Width |
1.535 in (3.899 cm) | ||
| Depth | 27.697 in (70.35 cm) | ||
| Capability | IEEE 802.2, 802.3, 802.3u | ||
|
Network Transfer Rate |
10 Base-T (half-duplex) |
10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (full-duplex) | 1000 Mbps | ||
| Fiber Channel SAN | Velio VC1070 re-timer | Auto-rate negotiate between 2G and 1G | |
|
Connector | Network | RJ-45 in the back. | |
| Fiber Channel SAN | Pluggable SFP optical slot in the front. | ||
|
Cable Support | 10 Base-TX | Categories
3, 4, or 5 UTP (2 or 4 pair); up to 328 ft (100 m) | |
| 100 Base-TX | Category 5 UTP (2 pair); up to 328 ft/100 m | ||
| 1000 Base-TX | Category 5E (4 pair); up to 328 ft (100 m) | ||
| Fiber Channel | SFP optical cable | ||
| EMI | FCC Class A | ||
| ICES-003 Class A | |||
| AS/NZS 3548 Class A | |||
| VCCI Class A | |||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
| | |||
| Operating and Performance Specifications for RJ-45 Patch Panel |
Dimensions | Height |
10.405 in (26.43 cm) |
| Width |
1.535 in (3.899 cm) | ||
| Depth | 27.697 in (70.35 cm) | ||
| Capability | IEEE 802.2, 802.3, 802.3u | ||
|
Network Transfer Rate |
10 Base-T (half-duplex) |
10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (full-duplex) | 1000 Mbps | ||
| Connector |
Network | RJ-45 in the back | |
| Cable Support | 10 Base-TX | Categories 3, 4, or 5 UTP
(2 or 4 pair); up to 328 ft (100 m) | |
| 100 Base-TX | Category 5 UTP (2 pair); up to 328 ft (100 m) | ||
| 1000 Base-TX | Category 5E (4 pair); up to 328 ft (100 m) | ||
|
Power Requirements | 200 mA at + 5V DC; 500 mA at -48V | ||
| Temperature Range | Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative
Humidity (non-condensing) | Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature | Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
| | |||
| Operating and Performance Specifications for GbE Interconnect Switch |
Dimensions |
Height |
10.405 in (26.43 cm) |
| Width |
1.535 in (3.899 cm) |
||
| Depth |
27.697 in (70.35 cm) |
||
| Weight | 11.5 lb/5.2 kg per interconnect switch | ||
|
Performance |
9.6 Gbps external port bandwidth per server blade enclosure (full duplex) | ||
| Forwarding rate 0.15 million pps per 10/100 port, 1.5 million pps per gigabit port, (64-byte packets) | |||
| Non-blocking, full-wire speed for all connections | |||
| Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support | |||
|
Forwarding Mode |
Store and forward | ||
| MAC Addresses | 8,191 per interconnect switch; MAC address based filtering and MAC address packet priority configuring | ||
| Forwarding Table Age Time |
Maximum age: 1 to 1,000,000 seconds; default: 300 seconds | ||
| Memory | 32MB Main, 6MB flash and 16MB packet buffer per interconnect switch | ||
| Compliance | IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE only), 802.1D, 802.1p, 802.3ac, 802.3ad (Static), and 802.1Q | ||
| SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9 | |||
| MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB (RFC 2674), Entity MIB (RFC 2037), SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757), and HP Enterprise Switch MIBs and Environmental Traps | |||
| IGMP v1 (RFC 1112), IGMP v2 (RFC 2236), SNTP (RFC 1361), Telnet (RFC 854), TFTP client (RFC 783), BootP client, (RFC 2132), DHCP client, (RFC 2131) and ZModem, | |||
| Network Transfer Rate |
10 Base-T (half-duplex) | 10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (half and full-duplex) | 2000 Mbps | ||
| 1000 Base-SX (full-duplex) | 2000 Mbps | ||
| Connector | 12 RJ-45, 2 DB-9 (C-GbE
Interconnect Kit) 4 LC fiber, 8 RJ-45, 2 DB-9 (F-GbE Interconnect Kit) |
||
| EMI | FCC Class A | ||
| ICES-003 Class A | |||
| AS/NZS 3548 Class A | |||
| VCCI Class A | |||
| Safety | UL/CUL Listed Accessory | ||
| CE | |||
| Power Requirements |
-48VDC: 1050 mA, 50 W maximum (per interconnect switch) | ||
| Temperature R range |
Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative Humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature |
Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
|
|
|||
| Operating and Performance Specifications for GbE2 Interconnect Switch |
Dimensions |
Height |
10.405 in (26.43 cm) |
| Width |
1.535 in (3.899 cm) |
||
| Depth |
27.697 in (70.35 cm) |
||
| Weight | 12.0 lb/5.4 kg per interconnect switch | ||
|
Performance |
24 Gbps External port bandwidth per server blade enclosure (full duplex) | ||
| Forwarding rate 1.5 million pps per gigabit port (64-byte packets) | |||
| Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support | |||
|
Forwarding Mode |
Store and forward | ||
| MAC Addresses | 2,048 per interconnect switch | ||
| Forwarding Table Age Time |
Maximum age: 1 to 65535 seconds; default: 300 seconds | ||
| Memory | 128MB Main, 32MB flash and 2MB packet buffer per interconnect switch | ||
| Compliance | IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE2 only), 802.1D, 802.3ac, 802.3ad (Static), and 802.1Q | ||
| SNMP v1 (RFC 1157), MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB , Entity MIB (RFC 2037), RADIUS Authentication MIB, 802.3-2002 MIB, SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757) and HP Enterprise Switch MIBs and Environmental Traps | |||
| RADIUS (RFC 2138), Telnet (RFC 854), TFTP client (RFC 783), SSH v1.5, SCP v1.5, NTP v2 (RFC 1119), BootP client (RFC 2132), and XModem | |||
| Network Transfer Rate |
10 Base-T (half-duplex) | 10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (half and full-duplex) | 2000 Mbps | ||
| 1000 Base-SX (full-duplex) | 2000 Mbps | ||
| Connector | 12 RJ-45, 2 DB-9 (C-GbE2
Interconnect Kit) 8 LC fiber, 4 RJ-45, 2 DB-9 (F-GbE2 Interconnect Kit) |
||
| EMI | FCC Class A | ||
| ICES-003 Class A | |||
| AS/NZS 3548 Class A | |||
| VCCI Class A | |||
| Safety | UL/CUL Listed Accessory | ||
| CE | |||
| Power Requirements |
48VDC: 2040 mA, 98 W
maximum (per interconnect switch without Storage Connectivity Kit) 48VDC: 2355 mA, 113 W maximum (per interconnect switch with Storage Connectivity Kit) |
||
| Temperature Range |
Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative Humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature |
Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa. | |||
|
|
|||
| Operating and Performance Specifications for CGESM Interconnect Switch |
Dimensions |
Height |
10.405 in (26.43 cm) |
| Width |
1.6 in (4.06 cm) |
||
| Depth |
28 in (71.12 cm) |
||
| Weight | 11.5 lb/5.2 kg per interconnect switch | ||
|
Performance |
28 Gbps Maximum Forwarding Bandwidth. 38.7mpps Maximum Forwarding Rate (64 Byte Packets) | ||
| 9018Bytes Jumbo Frames MTU | |||
| Non-blocking architecture. Wire Speed Performance on all ports | |||
| Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support | |||
|
Forwarding Mode |
Store and forward | ||
| MAC Addresses | 8000 MAC/physical address Table Size | ||
| Memory | 128MB DRAM Memory. 16MB Flash Memory | ||
| Compliance | IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3ad, IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and, IEEE 802.1D Spanning-Tree Protocol, IEEE 802.1p CoS Prioritization, IEEE 802.1Q VLAN, IEEE 802.3 10BASE-T specification, IEEE 802.3u 100BASE-TX specification, IEEE 802.3ab 1000BASE-T specification, IEEE 802.3z 1000BASE-X specification | ||
| RMON I and II standards, SNMPv1, SNMPv2c, and SNMPv3 | |||
| (RFC1493) , CISCO-CDP-MIB, CISCO-CLUSTER-MIB, CISCO-CONFIG-MAN-MIB, CISCO-ENTITY-FRU-CONTROL-MIB, CISCO-ENVMON-MIB, CISCO-FLASH-MIB, CISCO-FTP-CLIENT-MIB, CISCO-IGMP-FILTER-MIB, CISCO-IMAGE-MIB, CISCO IP-STAT-MIB, CISCO-MAC-NOTIFICATION-MIB, CISCO-MEMORY-POOL-MIB, CISCO-PAGP-MIB, CISCO-PING-MIB, CISCO-PROCESS-MIB, CISCO-RTTMON-MIB, CISCO-STP-EXTENSIONS-MIB, CISCO-SYSLOG-MIB, CISCO-TCP-MIB, CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB, CISCO-VLAN-MEMBERSHIP-MIB, CISCO-VTP-MIB, ENTITY-MIB, ETHERLIKE-MIB, IF-MIB (in and out counters for VLANs are not supported), IGMP-MIB, OLD-CISCO-CHASSIS-MIB, OLD-CISCO-FLASH-MIB, OLD-CISCO-INTERFACES-MIB, OLD-CISCO-IP-MIB, OLD-CISCO-SYS-MIB, OLD-CISCO-TCP-MIB, OLD-CISCO-TS-MIB, RFC1213-MIB (per the agent capabilities specified in the, CISCO-RFC1213-CAPABILITY.my), RFC1253-MIB, RMON-MIB, RMON2-MIB, SNMP-FRAMEWORK-MIB, SNMP-MPD-MIB, SNMP-NOTIFICATION-MIB, SNMP-TARGET-MIB, SNMPv2-MIB, TCP-MIB, UDP-MIB | |||
| 1000BASE-T ports, 1000BASE-X (SFP), 1000BASE-SX | |||
| Network Transfer Rate |
10 Base-T (half-duplex) | 10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (half and full-duplex) | 2000 Mbps | ||
| 1000 Base-SX (full-duplex) | 2000 Mbps | ||
| Connector | 4 SFP, 2 RJ-45 10/100/1000 T/TX/T, 1 DB-9 | ||
| EMI | FCC Part 15 Class A | ||
| EN 55022: 1998 (CISPR22)
EN 55024: 1998 (CISPR24) CNS 13438 Class A MIC CD MIC |
|||
| AS/NZS 3548 Class A CE | |||
| VCCI Class A | |||
| Safety | UL to UL 60950, Third
Edition C-UL to CAN/CSA C22.2 No. 60950-00, Third Edition TUV/GS to EN 60950:2000 CB to IEC 60950 with all country deviations NOM to NOM-019-SCFI |
||
| CE Marking | |||
| Power Requirements |
-48VDC: 1050 mA, 125 W maximum (per interconnect switch) | ||
| Temperature Range |
Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative Humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature |
Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
|
|
|||
|
Operating and Performance Specifications for Power Enclosures |
Single-Phase Model | Three-Phase Model | ||
| Dimensions | Height | 5.25 in (13.34 cm) | 5.25 in (13.34 cm) | |
| Width | 27.15 in (68.96 cm) | 27.15 in (68.96 cm) | ||
| Depth | 17.60 in (44.7 cm) | 17.60 in (44.7 cm) | ||
| Weights | No
Hot-Plug Power Supplies | 47.5 lb (21.55 kg) | 47.5 lb (21.55 kg) | |
| All Hot-Plug Power Supplies | 99.5 lb (45.13 kg) | 125.5 lb (56.93 kg) | ||
| Input Requirements | Rated input voltage | 200 VAC to 240 VAC | 200 VAC to 240 VAC line to line | |
| Rated input frequency | 50 Hz to 60 Hz | 50 Hz to 60 Hz | ||
| Rated input
current per side | 24A | 24A per phase | ||
| Rated input
power per side | 5760 W | 9976 W | ||
| Power cord | 1 NEMA L6-30P per side | 1 NEMA L15-30 per side | ||
| Output
Voltage Specifications | Rated output voltage | -48.8 VDC to -54 VDC | -48.8 VDC to -54 VDC | |
| Rated output current | 99A | 170A | ||
| Rated output power | 4298 W | 8310 W | ||
| Nominal power | 4158 W at 208 VAC | 7202 W at 208 VAC | ||
| Ambient
Temperature Range (See NOTE) |
Operating | 50°
to 95° F (10° to 35° C) | 50°
to 95° F (10° to 35° C) | |
| Shipping | -22°
to 140° F (-30° to 60° C) | -22°
to 140° F (-30° to 60° C) | ||
| Relative
humidity, non-condensing (See NOTE) | Operating | 20% to 80% | 20% to 80% | |
| Non-operating | 5% to 95% | 5% to 95% | ||
| Wet Bulb Temperature | Operating | 82.4° F (28° C) | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | ||||
| | ||||
|
Operating and Performance Specifications for Power Distribution Devices | Power Bus Box | Mini Bus Bar | Scalable Bus Bar | |
| Power
Enclosures or facility DC feeds Supported (3U each) | 1 | 1 | 2 | |
| Server blade enclosures supported (6U each) | 1 | 3 | 5 | |
| Total rack height of supported enclosures | 9U | 21U | 36U | |
| Dimensions | ||||
| Height | 5.1 in (12.95 cm) | 19.45 in (49.40 cm) | 48.57 in (123.37 cm) | |
| Width | 3.6 in (9.14 cm) each | 19.74 in (50.14 cm) | 19.74 in (50.14 cm) | |
| Depth | 3.25 in (8.26 cm) | 2.2 in (5.59 cm) | 2.2 in (5.59 cm) | |
| Weight | 3.62 lb (1.64 kg) | 13.2 lb (5.9 kg) | 26 lb (11.79 kg) | |
| Rated Operating Voltage | -43.2 VDC to -54 VDC | -43.2 VDC to -54 VDC | -43.2 VDC to -54 VDC | |
| Max Total Power Supported | 3000 W | 9000 W | 15000 W | |
| Total
Max Input Current At Minimum Voltage | 69.44 A at -43.2VDC | 208.32 A at -43.2 VDC | 347.2 A at -43.2 VDC (equivalent of 175A per feed) | |
| Total
Max Input Current At Nominal Voltage | 62.5 A at -48VDC | 187.5 A at -48 VDC | 312.5
A at -48 VDC (equivalent of 175A per feed) | |
| Max
Current Per Power Feed | 70A | 70A | 210A | |
| Max Local Ambient Temperature | 149° F (65° C) | 149° F (65° C) | 149° F (65° C) | |
| NOTE: All systems support redundant A & B feeds. Scalable bus bar supports dual A and dual B feeds. | ||||
|
| ||||
|
Operating and Performance Specifications for Facility DC |
Voltage |
Nominal input voltage |
-48 VDC |
| Operating voltage range |
-48VDC ± 10% or -43.2 VDC to -52.8 VDC |
||
| Max Input voltage slew rate | 0.5V/uS | ||
| Redundant feed voltages* (A & B) |
*A and B feeds must differ by no more than 5VDC during steady state operation | ||
| Ripple/Noise | 480 mV PARD** | ||
| Overshoot | Must remain within regulation limits on all feeds during startup or shutdown | ||
| Voltage transients |
Must not exceed -60 VDC |
||
|
Current |
Max steady state input current | 62.5A per server blade enclosure installed at -48VDC | |
| Max steady state current per feed/total | |||
|
70 A/70A | ||
|
210 A/210A | ||
|
210 A/350A or equivalent of 175A per feed* | ||
| In-rush current | Must support up to 2X the maximum operating current per server blade enclosure (125 A) for up to 1.0 mS | ||
| Input over-current | Customer provided fusing for facility DC feeds that protects the system from catastrophic over-current within 20 uS. Fuse should sustain all in-rush and operating currents. | ||
| Max Input Current Slew Rate | 1A/uS | ||
| Max Rated Power | 3000W per server blade enclosure | ||
|
Connections and Cables |
Compaq provided facility DC cable connection kit: | ||
|
|||
| The power cable assemblies consist of 1/0AWG, color-coded, flexible cable rated at 105° C, terminated with bus mating connectors at one end and unterminated at the other end. The cable length provided enables the customer to route to a fuse panel within or adjacent to the rack. | |||
| NOTE: *All systems support redundant A and B feeds. Scalable bus bars support dual A and dual B feeds. | |||
| ** Periodic and random noise (PARD). Maximum allowable peak-to-peak ripple and noise (as measured at the load on any output channel). The ripple and noise is measured over a 20 Hz to 100 MHz frequency band. A resistive load (non-electronic) is used for this measurement. Each output is by-passed to return by a 10uF tantalum capacitor with an ESR less than 100 milli-Ohms in parallel with a 0.47 uF ceramic capacitor, at the point of load. The load cable is 12 feet of twisted wire capable of carrying the current. The printed wiring board assembly is installed in its enclosure for this measurement, or the measurement leads are properly shielded with Earth grounds applied to the insert. | |||
|
|
|||
|
© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |