Overview
| HP ProLiant DL760 Generation 2 (G2)
| ||||||||||||||||||||
| What's New
|
At
A Glance
|
|
|
Standard Features
| Processor One of the following depending on Model |
(4) Intel Xeon Processor MP 3.0 GHz/4MB |
| (4) Intel Xeon Processor MP 2.7 GHz/2MB | |
| (4) Intel Xeon Processor MP 2.2 GHz/2MB | |
|
|
|
| Cache
Memory One of the following depending on Model |
4-MB Integrated Level 3 cache
(per processor) NOTE: Available with 3.0 GHz models. |
| 2-MB integrated level 3 cache
(per processor) NOTE: Available with 2.7 GHz or 2.2 GHz models. |
|
|
|
|
| Upgradeability | Upgradeable to eight processors |
| | |
| Chipset | HP developed F8 chipset |
|
|
|
| Memory Protection | Advanced ECC |
| Hot Plug RAID Memory | |
|
|
|
| Memory |
Type | 133MHz ECC SDRAM DIMMs |
| Standard NOTE: Available with 2.2 GHz model. |
2 GB | |
| Standard NOTE: Available with 3.0 GHz or 2.7 GHz models. |
4 GB | |
| Maximum | 64 GB (80 GB total) | |
| NOTE:
All models come standard with all five memory cartridges populated and Hot
Plug RAID Memory enabled. NOTE: In standard Hot Plug RAID Memory mode, addressable memory refers to the portion of memory that is addressable by the OS. Total memory consists of addressable memory plus the redundant memory (stored in the dedicated parity memory cartridge.) |
||
|
|
||
| Network Controller | Integrated HP NC7170 Dual-Port
PCI-X 1000T Gigabit Server Adapter in a slot NOTE: Available with 3.0 GHz, 2.7 GHz, and 2.2 GHz models. |
|
|
|
| Expansion Slots |
Slot Number
|
Bus Speed
|
Bus Number
|
Hot Plug
|
PCI Voltage
|
Notes
|
|
1
|
64-bit 100MHz
PCI-X |
11
|
Yes
|
3.3V
|
||
|
2
|
64-bit 100MHz
PCI-X |
11
|
Yes
|
3.3V
|
||
|
3
|
64-bit 100MHz
PCI-X |
9
|
Yes
|
3.3V
|
||
|
4
|
64-bit 100MHz
PCI-X |
9
|
Yes
|
3.3V
|
||
|
5
|
64-bit 100MHz
PCI-X |
7
|
Yes
|
3.3V
|
||
|
6
|
64-bit 100MHz
PCI-X |
7
|
Yes
|
3.3V
|
||
|
7
|
64-bit 100MHz
PCI-X |
5
|
Yes
|
3.3V
|
||
|
8
|
64-bit 100MHz PCI-X
|
5
|
Yes
|
3.3V
|
||
|
9
|
64-bit 33MHz PCI
|
1
|
Yes
|
5V
|
Supported RILOE slot
|
|
|
10
|
64-bit 100MHz
PCI-X |
3
|
Yes
|
3.3V
|
||
|
11
|
64-bit 100MHz
PCI-X |
3
|
Yes
|
3.3V
|
NIC in slot
|
|
| NOTE:
For more information regarding PCI-X, please see the following URL: http://www.hp.com/servers/pci-x. |
||||||
| NOTE: All slots can accept universal keyed PCI cards. | ||||||
|
|
||||||
| Storage Controllers | Smart Array 5i Controller (integrated on system board) supports (Ultra3) (supports RAID 0, 1, 1+0, and 5 across internal hard disk drives) | ||
| Optional support for Ultra3 or Ultra320 storage controllers in an I/O slot to internal drives via array bypass cable kit and required cables ships with all HP ProLiant DL760 in the accessories package. | |||
|
|
|||
| Storage | Diskette Drive | Integrated 1.44 MB Diskette Drive |
| Optical Drive | Integrated Slimline CD/DVD-ROM Drive (8X speed for DVD and 24X speed for CD) | |
| Hard Drives | None | |
|
|
||
| Maximum Internal Storage Type | Hot Plug SCSI | 1.20TB | 4
x 300GB Ultra320 Drives (internal hot plug cage only) NOTE: The Ultra320 drives run at Ultra3 speeds. |
|
| |||
| Interfaces | Serial | 1 |
| Pointing Device (Mouse) | 1 | |
| Graphics | 1 | |
| Keyboard | 1 | |
| Network RJ-45 | 1 | |
|
|
||
| Graphics | Integrated ATI RAGE XL Video Controller with 8-MB SDRAM Video Memory |
|
|
|
| Form Factor | 7U Rack Form Factor; Ships with sliding rack rails and cable management arm; Standard 19" rack-mountable |
|
|
|
|
ProLiant Essentials Foundation Pack Software |
| ||
| |||
| |||
| |||
| |||
| |||
| |||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials | |||
| | |||
| Industry Standard Compliance | ACPI 1.0b Compliant |
| PCI-X and PCI 2.2 Compliant | |
| PAE Support | |
| Microsoft® Logo certifications | |
|
|
|
| Intelligent Manageability | HP Systems Insight Manager Remote Insight Lights-Out Edition ll (optional) ROM-Based Setup Utility (RBSU) Integrated Management Display (IMD) Server Health logging Automatic Server Recovery-2 (ASR-2) System Interconnect Status Indicators Remote-Flash Redundant ROM Hot Spare Boot NOTE: Upon the event of a failed processor or VRM in a multi-processing environment, the system will automatically reboot and use the remaining good processor(s). Power Down Utility Power Supply Viewer Pre-Failure Warranty (covers processors, as well as SCSI hard drives and memory) |
|
|
|
| Availability | Hot Plug RAID Memory using Industry
Standard ECC Memory PCI-X/PCI Hot Plug with push button functionality Redundant Hot Plug Fans Dynamic sector repairing and drive parameter tracking (with Smart Array controllers) Fault Tolerant Processor Power Modules Redundant/adaptive load balancing NIC Support Redundant Hot Plug Power Supplies |
|
|
|
| Security | Power-on password Diskette drive control Diskette boot control Network server mode Security provision Parallel and serial interface control Administrator's password Disk configuration lock Hot plug access security |
|
|
|
| Server Power Cords | Two Highline IEC to IEC power cords (PDU adapters) ships standard |
|
|
|
| UPS
and PDU Power Cord Matrix |
Please see the UPS and
PDU cable matrix that lists cable descriptions, requirements, and specifications
for UPS and PDU units. ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf. |
| | |
| Power Supply | Two Redundant Hot Plug
1150/500-Watt power supplies per system. Power supplies are load sharing and provide
1150 Watts of Redundant power for 220-volt input or 500 Watts of Redundant power
for 110-volt input. NOTE: To ensure redundancy of server power, HP requires that 200-240 VAC power be used for all deployments. This will ensure that both power supplies can support up to their maximum configurations, and remain in a redundant power supply state. NOTE: A maximum of two power supplies are supported and ship standard with each server. |
| | |
| System Fans | Two Hot-Plug redundant fans ship standard. Two maximum supported. |
|
|
|
| Required Cabling | For required cabling
information, refer to the Web site at: http://hp.com/products/servers/ProLiantDL760. |
| | |
| OS Support | Microsoft Windows 2000 Microsoft Windows 2000 Advanced Server Microsoft Windows Server 2003 (Standard, and Enterprise) SCO UnixWare® LINUX (Red Hat, SuSE) VMware Virtualization Software |
| NOTE: For a
more complete and up-to-date listing of supported OS's and versions, please
visit our OS Support Matrix at: http://www.hp.com/go/supportos. NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant DL760 G2, please see: http://h18023.www1.hp.com/support/files/server/us/index.html. NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux Web site at http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html. NOTE: For more complete and up-to-date information on how to buy server operating systems from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html. |
|
|
|
|
| Rack Airflow Requirements |
Rack 10000 series Cabinets CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
|
NOTE: For additional information, refer to the Setup and Installation Guide
or the Documentation CD provided with the server, or to the server documentation
located in the Support section at the following URL: http://h18000.www1.hp.com/products/servers/ProLiantdl760/index.html. NOTE: Allow a minimum of 48 in (121.92 cm) clearance beyond the front of your rack to permit server installation and removal. This applies to both individual rack installations as well as when aligning rack rows so that the front doors are facing each other. | |
| | |
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
|
|
|
| Custom Builder | |
| Please see the Enterprise Configurator for configuration assistance at: http://www.hp.com/products/configurator. | |
| | |
| Service and Support | This product is covered by a
global limited warranty and supported by HP Services and a worldwide network
of resellers and service providers. Hardware diagnostic support and repair
is available for three years from date of purchase. Support for software
and initial setup is available for 90 days from date of purchase. Additional
support may be covered under the warranty or available for an additional
fee. Enhancements to warranty services are available through HP Care Pack
services or customized service agreements.
NOTE: Limited warranty includes 3 year parts, 3 year labor, 3-year on-site support. Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware and software services are available including:
HP Care Pack services include coverage for the HP branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to 3kVA; these items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. |
|
NOTE: For more information on HP Care
Pack services, contact any of our worldwide sales offices or resellers
or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack |
|
|
Models
|
Model DL760R02 X3.0-4MB, 4096MB (4P) | Processor(s) | (4) Intel Xeon Processors MP at 3.0 GHz standard (up to 8 supported) |
| Cache Memory | 4-MB integrated Level 3 cache (per processor) | |
| Memory | 4096 MB (Standard) to 64 GB (Maximum) addressable protected 133MHz ECC SDRAM DIMM (5120 MB total) | |
| Network Controller | Integrated HP NC7170 Dual-Port PCI-X 1000T Gigabit Server Adapter in a slot | |
| Storage Controller | Integrated Smart Array 5i Controller (Ultra 3 support) (supports RAID 0, 1, 1+0, and 5 across internal hard disk drives) | |
| Hard Drives | None | |
| Internal Storage | 1.20TB maximum (with optional hard drives) | |
| Cache Accelerator | 2-MB Cache coherency accelerator embedded on host board | |
| Optical Drive | Integrated Slimline CD/DVD-ROM Drive (8X/24X) | |
| Diskette Drive | Integrated 1.44 MB Diskette Drive | |
| I/O Slots | PCI and PCI-X | |
| Form Factor | 7U Rack Form Factor | |
| | ||
|
Model DL760R02 X2.7-2MB, 4096MB (4P) | Processor(s) | (4) Intel Xeon Processors MP at 2.7 GHz standard (up to 8 supported) |
| Cache Memory | 2-MB integrated Level 3 cache (per processor) | |
| Memory | 4096 MB (Standard) to 64 GB (Maximum) addressable protected 133MHz ECC SDRAM DIMM (5120 MB total)\ | |
| Network Controller | Integrated HP NC7170 Dual-Port PCI-X 1000T Gigabit Server Adapter in a slot | |
| Storage Controller | Integrated Smart Array 5i Controller (Ultra 3 support) (supports RAID 0, 1, 1+0, and 5 across internal hard disk drives) | |
| Hard Drives | None | |
| Internal Storage | 1.20TB maximum (with optional hard drives) | |
| Cache Accelerator | 2-MB Cache coherency accelerator embedded on host board | |
| Optical Drive | Integrated Slimline CD/DVD-ROM Drive (8X/24X) | |
| Diskette Drive | Integrated 1.44 MB Diskette Drive | |
| I/O Slots | PCI and PCI-X | |
| Form Factor | 7U Rack Form Factor | |
| | ||
| Model
DL760R02 X2.2-2MB, 2048MB (4P) 348444-B21 | Processor(s) | (4) Intel Xeon Processors MP at 2.2 GHz standard (up to 8 supported) |
| Cache Memory | 2-MB integrated Level 3 cache (per processor) | |
| Memory | 2048 MB (Standard) to 64 GB (Maximum) addressable protected 133MHz ECC SDRAM DIMM (2560 MB total) | |
| Network Controller | Integrated HP NC7170 Dual-Port PCI-X 1000T Gigabit Server Adapter in a slot | |
| Storage Controller | Integrated Smart Array 5i Controller (Ultra 3 support) (supports RAID 0, 1, 1+0, and 5 across internal hard disk drives) | |
| Hard Drives | None | |
| Internal Storage | 1.20TB maximum (with optional hard drives) | |
| Cache Accelerator | 2-MB Cache coherency accelerator embedded on host board | |
| Optical Drive | Integrated Slimline CD/DVD-ROM Drive (8X/24X) | |
| Diskette Drive | Integrated 1.44 MB Diskette Drive | |
| I/O Slots | PCI and PCI-X | |
| Form Factor | 7U Rack Form Factor |
|
|
Options
| ProLiant
Essentials Value Pack Software |
ProLiant Essentials Intelligent Networking Pack | |
| ProLiant Essentials
Intelligent Networking Pack - Windows Edition, Single Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372906-B21 |
|
| NOTE: For additional ProLiant Intelligent Networking Pack - Windows License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12062_na/12062_na.html | ||
| ProLiant Essentials Intelligent Networking Pack - Linux Edition, Single Server License |
397004-B21
|
|
| NOTE:
For additional ProLiant Intelligent Networking Pack - Linux License
Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12327_na/12327_na.html |
||
| ProLiant Essentials Performance Management Pack | ||
| ProLiant Essentials
Performance Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key, HP Management CD and documentation. NOTE: The most recent version of the software can always be downloaded at http://www.hp.com/products/pmp. |
306696-B21 |
|
| NOTE: For additional ProLiant Performance Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_na/11925_na.html | ||
| ProLiant Essentials Rapid Deployment Pack Windows Edition and Linux Edition Release | ||
| Rapid Deployment
Pack, Single-Server License NOTE: This license allows 1 server to be deployed and managed via RDP. |
267196-B21 |
|
| Rapid Deployment
Pack, Single-Server License (Japan) NOTE: This license allows 1 server to be deployed and managed via RDP. |
267196-291 |
|
| NOTE:
For additional ProLiant Essentials Rapid Deployment Pack License Kits please
see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.html http://h18000.www1.hp.com/products/quickspecs/11713_na/11713_na.html |
||
| ProLiant Essentials Workload Management Pack | ||
| ProLiant Essentials Workload Management Pack, Single Server License |
303284-B21
|
|
| NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_na/11452_na.html | ||
| ProLiant Essentials Virtualization Management Software | ||
| ProLiant Essentials
Virtual Machine Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372214-B21 |
|
| ProLiant Essentials
Server Migration Pack, Single-Migration License NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation. NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005. |
||
| NOTE: For additional ProLiant Essentials Virtualization Management Software License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_na/12328_na.html | ||
| ProLiant Essentials Vulnerability and Patch Management Pack | ||
| ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
371645-B21
|
|
| NOTE: For additional ProLiant Vulnerability and Patch Management Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_na/12111_na.html | ||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. |
||
|
|
||
| NetServer to ProLiant integrations services | HP NetServer to ProLiant
integration and assessment service |
304164-002
|
| NOTE: HP identifies current levels of NetServer support, services, and management. This service helps maximize customer’s ability to add ProLiant platforms into their current environment. | ||
| HP TopTools to Insight
Manager 7 installation and startup service |
304163-002
|
|
| NOTE: Provides on-site review, installation and configuration services for Insight Manager 7. HP will also re-create, as closely as possible, the views and reports from the customer’s current TopTools configuration. This service assures a smooth transition to the ProLiant Essentials software. | ||
| HP NetServer to ProLiant Essentials Rapid Deployment Pack installation and startup service |
304162-002
|
|
| NOTE: Install and configure Rapid Deployment Pack in a test environment, then deploy a server image to a maximum of 250 systems in the production environment. This service helps to assure successful system deployment. | ||
|
|
||
| Processor | NOTE: Intel Xeon 3.0 GHz/4MB, 2.7 GHz/2MB, 2.2 GHz/2MB, 2.8 GHz/2MB, 2.5 GHz/1MB, 2.0 GHz/2MB, 2.0 GHz/1MB, and 1.5 GHz/1MB processors cannot be mixed in the same server. They all have to be of the same speed. | |
| (4)
Intel Xeon MP 3.0 GHz -4MB Processor Option Kit NOTE: This processor option kit (PN 351050-B21) supports the HP ProLiant DL760 G2 and the HP ProLiant DL740 servers. This option kit contains 4 x Intel Xeon MP 3.0GHz/4MB processors. |
351050-B21 | |
| (4)
Intel Xeon MP 2.70 GHz -2MB Processor Option Kit NOTE: This processor option kit (PN 351051-B21) supports the HP ProLiant DL760 G2 and the HP ProLiant DL740 servers. This option kit contains 4 x Intel Xeon MP 2.70 GHz/2MB processors. |
351051-B21 | |
| (4)
Intel Xeon MP 2.20 GHz -2MB Processor Option Kit NOTE: This processor option kit (PN 351052-B21) supports the HP ProLiant DL760 G2 and the HP ProLiant DL740 servers. This option kit contains 4 x Intel Xeon MP 2.20 GHz/2MB processors. |
351052-B21 | |
| (4)
Intel Xeon MP 2.80 GHz -2MB Processor Option Kit NOTE: This processor option kit (PN 334037-B21) supports the HP ProLiant DL760 G2 and the HP ProLiant DL740 servers. This option kit contains 4 x Intel Xeon MP 2.80 GHz-2MB processors. |
334037-B21 | |
| (4) Intel Xeon MP 2.50 GHz-1MB
Processor Option Kit NOTE: This processor option kit (PN 339072-B21) supports the HP ProLiant DL760 G2 and HP ProLiant DL740 servers. This option kit contains 4 x Intel Xeon MP 2.50 GHz-1MB processors. |
339072-B21 | |
| (4) Intel Xeon MP 2.0 GHz-1MB
Processor Option Kit NOTE: This processor option kit (PN 334036-B21) supports the HP ProLiant DL760 G2 and HP ProLiant DL740 servers. This option kit contains 4 x Intel Xeon MP 2.0 GHz-1MB processors. |
334036-B21 | |
| (4) Intel Xeon MP 2.0 GHz -2MB
Processor Option Kit NOTE: This processor option kit (PN 287520-B21) supports the HP ProLiant DL760 G2 and the HP ProLiant DL740 servers. This option kit contains 4 x Intel Xeon MP 2.0 GHz-2MB processors. |
287520-B21 | |
| (4) Intel Xeon MP 1.50 GHz-1MB
Processor Option Kit NOTE: This processor option kit (PN 287519-B21) supports the HP ProLiant DL760 G2 and HP ProLiant DL740 servers. This option kit contains 4 x Intel Xeon MP 1.50 GHz-1MB processors. |
287519-B21 | |
| | ||
|
Memory |
2048 MB 133MHz ECC SDRAM
Memory Option Kit (1 x 2048 MB) NOTE: A ROM dated later than 2/14/2003 is needed to use 2 GB DIMMs. |
317093-B21
|
| 1024 MB 133MHz ECC SDRAM Memory Option Kit (1 x 1024 MB) |
236854-B21
|
|
| 512 MB 133MHz ECC SDRAM Memory Option Kit (1 x 512 MB) |
236853-B21
|
|
| 256 MB 133MHz ECC SDRAM Memory Option Kit (1 x 256 MB) |
236852-B21
|
|
| NOTE: Memory must be populated in banks of 10. (2 per memory cartridge x 5 cartridges.) All DIMMs in a bank must be the same sku number. | ||
|
|
||
| Optical Drives | 8x CD/DVD-ROM Drive Option Kit | 337057-B21 |
| | ||
| Hard Drives | Ultra320 SCSI – Universal Hot Plug | |
| HP 300GB U320 10K Universal HDD |
350964-B22 | |
| HP 146GB U320 10K Universal HDD |
286716-B22 | |
| HP 72GB U320 10K Universal HDD | 286714-B22 | |
| HP 146GB U320 15K Universal HDD |
347708-B22 | |
| HP 72GB U320 15K Universal HDD | 286778-B22 | |
| HP 36GB U320 15K Universal HDD |
286776-B22 | |
| NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320 Smart Array Controller or U320 SCSI HBA to support U320 transfer rates. | ||
| NOTE: Please see
the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature: http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html | ||
| | ||
| Storage Controllers | Smart Array 6402/128 Controller | 273915-B21 |
| Smart Array 6404/256 Controller |
273914-B21
|
|
| 512MB DDR BBWC Upgrade | 372538-B21 | |
|
Smart Array 641 Controller |
291966-B21 |
|
|
Smart Array 642 Controller |
291967-B21 |
|
| 128MB Battery-Backed Cache Enabler NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array 642 Controller. |
351580-B21 | |
|
256-MB Battery-Backed Cache Module |
254786-B21 |
|
|
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter |
268351-B21 |
|
| Ultra320 Expansion Module for
SA-6402 |
273911-B21 | |
| NOTE: Please see
the following Controller or SCSI Adapter QuickSpecs for Technical Specifications
such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported,
SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache,
RAID support, and additional information: http://h18000.www1.hp.com/products/quickspecs/11587_na/11587_na.html (Smart Array 6400 Series) http://h18000.www1.hp.com/products/quickspecs/12067_na/12067_na.html (Smart Array 641) http://h18000.www1.hp.com/products/quickspecs/12069_na/12069_na.html (Smart Array 642) http://h18000.www1.hp.com/products/quickspecs/10429_na/10429_na.html (SCSI Adapter) http://h18000.www1.hp.com/products/quickspecs/11555_na/11555_na.html (U320 Adapter) |
||
|
|
||
| Communications | HP NC310F PCI-X 1000SX Gigabit Server Adapter | 368169-B21 |
| HP NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter | 313881-B21 | |
| HP NC7771 PCI-X 1000T Gigabit Server Adapter | 290563-B21 | |
| HP NC570C PCI-X Dual-port 4x Fabric Adapter | 376158-B21 | |
| HP 24-Port 4x Fabric Copper Switch | 376227-B21 | |
| HP 1m 4x Fabric Copper Cable | 376232-B21 | |
| HP 3m 4x Fabric Copper Cable | 376232-B22 | |
| HP 5m 4x Fabric Copper Cable | 376232-B23 | |
|
|
||
|
Redundant Options |
1150/500-Watt Hot Plug N 1 redundant power supply |
401231-001 |
|
NOTE: A maximum of two power supplies are supported by the HP ProLiant DL760 G2 (shipped standard with each server). |
||
|
|
||
|
Management Options |
Remote Insight Lights-Out Edition II |
227251-001 |
|
|
||
|
Tape Drives |
| ||||||||||||||||||||||||||||||||||||
| | |||||||||||||||||||||||||||||||||||||
| Tape Autoloaders | DAT Autoloader | |
| HP StorageWorks DAT 72x6 Autoloader (External) | Q1567A | |
| NOTE:
Please see the DAT Tape Autoloader QuickSpecs for additional options such as host
bus adapters, controllers and media: http://h18000.www1.hp.com/products/quickspecs/11985_na/11985_na.html | ||
| HP StorageWorks 1/8 Tape Autoloader | ||
| HP StorageWorks 1/8 Ultrium 960 Tape Autoloader | AF204A | |
| HP StorageWorks 1/8 Ultrium 448 Tape Autoloader | AF203A | |
| HP StorageWorks 1/8 Ultrium 232 Tape Autoloader | AF202A | |
| 1/8 Tape Autoloader Rackmount
Kit NOTE: Required to install the unit in a standard 19-inch rack; includes rails and rackmount instructions. | C9268R | |
| NOTE: Please reference the 1/8 Tape Autoloader QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. | ||
| | ||
| Tape Libraries | HP StorageWorks MSL2024 Tape Library | |
| HP StorageWorks MSL2024 1 Ultrium
960 Drive Library |
AG115A
|
|
| HP StorageWorks MSL2024 1 Ultrium 448 Drive Library |
AG116A
|
|
| HP StorageWorks MSL2024 2 Ultrium 448 Drive Library |
AG117A
|
|
| HP StorageWorks MSL4048 Tape Library |
||
| HP StorageWorks MSL4048 1 Ultrium
448 Drive Library |
AG320A
|
|
| HP StorageWorks MSL4048 2 Ultrium
448 Drive Library |
AG321A
|
|
| HP StorageWorks MSL4048 1 Ultrium
960 Drive Library |
AG322A
|
|
| HP StorageWorks MSL4048 2 Ultrium 960 Drive Library |
AG323A
|
|
| HP StorageWorks MSL6000 Tape Library | ||
| Ultrium 960 technology | ||
| HP StorageWorks MSL6030 1 Ultrium 960 Dr LVDS Library | AD606A | |
| HP StorageWorks MSL6030 1 Ultrium
960 Dr FC Library |
AD608A | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr LVDS Library | AD607A | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr FC Library | AD609A | |
| Ultrium 460 technology | ||
| HP StorageWorks MSL6030 1 Ultrium
460 Dr LVDS Library |
AD598A | |
| HP StorageWorks MSL6030 1 Ultrium 460 Dr FC Library | AD600A | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr LVDS Library | AD599A | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr FC Library | AD601A | |
| NOTE: Please reference the MSL2024, MSL4048 and MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. | ||
|
|
||
| Magneto-Optical Jukeboxes | HP StorageWorks 9.1 GB Optical Jukeboxes | |
| 600mx, 4 drive, 64 slot jukebox |
C1160M
|
|
| 1200mx, 4 drive, up to 128 slots |
C1104M
|
|
| 2200mx, 6 drive, up to 238 slots |
C1107M
|
|
| NOTE: Please see the HP StorageWorks
Magneto-Optical Products data sheet for a complete listing of available
jukeboxes at: http://www.hp.com/products1/storage/products/archivalprod/brochures/ MO_family_pb.pdf NOTE: Please reference the Magneto-Optical Jukebox data sheets at http://www.hp.com/go/optical for additional information needed to create a complete solution. |
||
|
|
||
| Ultra Density Optical Jukeboxes | 1900ux, 4 drive, 64 slot jukebox | AA966A |
| 3800ux, 4 drive, 128 slot jukebox | AA969A | |
| 7100ux, 6 drive, 238 slot jukebox | AA971A | |
| NOTE: Please see
the HP StorageWorks Ultra Density Optical Jukeboxes QuickSpecs for a complete
listing of available jukeboxes at: http://h18006.www1.hp.com/products/quickspecs/11944_na/11944_na.html NOTE: Please reference the Ultra Density Optical Jukebox QuickSpecs at http://www.hp.com/go/optical for additional information needed to create a complete solution. |
||
|
|
||
| HP Data Protector Express Software | HP DP Express Backup Server Upgrade
for ProLiant Software |
BB117AP |
| HP DP Express Package for Microsoft
Small Business Server |
BB118AA | |
| NOTE: Please see
the HP Data Protector Express QuickSpecs for additional information regarding
the purchase of HP Data Protector Express software: http://h18000.www1.hp.com/products/quickspecs/12337_na/12337_na.html |
||
| | ||
| HP StorageWorks Modular Smart Array 20 | HP
StorageWorks Modular Smart Array 20 NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. | 335921-B21 |
| HP StorageWorks Modular Smart
Array 20 Starter Kit NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. Includes Smart Array 6402/128 Controller. | 366172-B21 | |
| NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 3.5" Hot Plug Hard Drives. | ||
| | ||
| HP StorageWorks Modular Smart Array 30 | HP
StorageWorks Modular Smart Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies. | 302969-B21 |
| HP StorageWorks Modular Smart
Array 30 DB NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies. | 302970-B21 | |
| NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 Hot Plug Hard Drives. | ||
| | ||
|
HP StorageWorks Modular Smart Array 500 |
HP StorageWorks Modular Smart Array 500 Generation 2 |
335880-B21
|
| NOTE:
Please see the Modular Smart Array 500 Generation 2 QuickSpecs for additional
information including configuration steps and additional options needed
for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/11956_na/11956_na.html |
||
|
|
||
|
HP StorageWorks Modular Smart Array 1000 |
HP StorageWorks Modular Smart Array 1000 |
201723-B22
|
| NOTE:
Please see the Modular Smart Array 1000 QuickSpecs for additional options
and configuration information at http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html |
||
|
|
||
|
HP StorageWorks Modular Smart Array 1500 cs |
Modular Smart Array 1500 Controller Shelf |
AA986A
|
| NOTE:
Please see the StorageWorks Modular SAN Array 1500 cs QuickSpecs for additional
options and configuration information at: http://www.hp.com/go/MSA1500cs |
||
|
|
||
| Cluster Options | ProLiant Cluster Starter Kit | 364023-B21 |
| NOTE: For additional
information regarding the ProLiant Cluster Starter Kit please see the following
QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11935_na/11935_na.html | ||
| HP HA/F200 for Entry SAN Cluster |
364026-B22 | |
| NOTE:
For additional information regarding the ProLiant Cluster for Entry Level SAN
please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11932_na/11932_na.html | ||
| ProLiant Cluster HA/F500 for the Enterprise SAN | 364024-B21 | |
| NOTE: For additional
information regarding the ProLiant Cluster HA/F500 for Enterprise SAN please see
the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11933_na/11933_na.html | ||
| HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 and Red Hat EL 3 & 4 (2 node license cluster kit) | 305199-B26 | |
| HP Serviceguard for Linux A.11.16 for SUSE SLES9 and Red Hat EL 3 & 4 (single license version) | 307754-B26 | |
| HP Serviceguard for Linux and Red Hat Global File System - 1 year subscription | T2798AA#001 | |
| HP Serviceguard for Linux and Red Hat Global File System - 3 years subscription | T2798AA#003 | |
| NOTE: For additional
information regarding HP Serviceguard for Linux, please see the following QuickSpecs
at: http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html | ||
|
| ||
|
Uninterruptible Power Systems – Rack Mountable |
HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage |
204404-001 |
|
HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage |
192186-001 |
|
|
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage |
192186-002 |
|
| HP UPS R5500 XR, (5000VA, 4500 Watt), High Voltage | 326529-D71 | |
| UPS R12000 XR N+x (200-240V) (hardwired) |
207552-B22
|
|
|
NOTE: The UPS R12000 XR has a hardwired input and output; requires a 100A circuit. |
|
|
|
|
||
| HP Monitored Power Distribution Unit (PDU) | HP Monitored Power Distribution Unit: Full Rack Version | |
| HP 17.3 kVA S2324 Monitored PDU- dual input, 3-phase, 24A |
370959-D71 | |
| HP 8.3 kVA S1324 Monitored PDU- single input, 3-phase, 24A |
370960-D71 | |
| HP 16.6 kVA S2140 Monitored PDU- dual input, 1-phase, 40A |
370961-D71 | |
| HP 8.6 S1140 Monitored PDU- single input, 1-phase, 40A |
370962-D71 | |
| HP Monitored Power Distribution Unit: Half Rack Version | ||
| HP 17.3 kVA S348 Monitored PDU- single input, 3-phase, 60A |
AF916A | |
| | ||
|
Modular PDUs 1U/0U |
HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127
VAC) |
252663-D71 |
|
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC) |
252663-D72 |
|
| HP Modular Power Distribution Unit (mPDU), High Volt Model, 40A, Attached Cord |
252663-D73
|
|
| NOTE: Please see
the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables and country specific
power cords: http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html |
||
|
|
||
|
Third Party Rack Kit |
Rack Adapter Kit NOTE: This kit allows HP rack servers to fit in racks that are 24" wide. |
332815-B21 |
|
Third Party Rack Kit |
274739-B21 |
|
| NOTE: The Third party rack kit supports the HP ProLiant ML530 G2, HP ProLiant ML570 G2, HP ProLiant DL740, and HP ProLiant DL760 G2. Provides support for any rack, square hole or round hole (including HP Rack System /E and HP Systems) with an adjustment range from 23 ½" – 34" deep. | ||
| NOTE: The Third Party Rack Kit is required for round hole racks or for square hole racks that do not conform to the adjustment range of the standard rail that ships with the server. | ||
| Telco Rack Support NOTE: Support for all 2-post Telco racks requires the Third Party Rack Kit (PN 274739-B21) kit plus an additional option kit from Rack Solutions. The Rack Solutions brackets can be purchased at: http://www.racksolutions.com/compaq. | ||
|
|
||
| HP Rack 5000 Series (Graphite Metallic) | HP 5642 Rack-Unassembled |
358254-B21
|
| NOTE:
Please see the HP Rack 5642 QuickSpecs for additional part numbers and
Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.html NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. |
||
|
|
||
|
HP Rack 10000 G2 Series (Carbon/Graphite Metallic) | 10642 G2 (42U) Rack Cabinet - Pallet | AF001A |
| 10642 G2 (42U) Rack Cabinet - Shock Pallet | AF002A | |
| 10642 G2 (42U) Rack Cabinet - Crated | AF003A | |
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet | AF004A | |
| 10642 G2 (42U) Rack Cabinet, without door - Shock Pallet | AF005A | |
| 10642 G2 (42U) Rack Cabinet - with Extension, without door - Shock Pallet | AF006A | |
| 10636 G2 (36U) Rack Cabinet - Pallet | AF011A | |
| 10636 G2 (36U) Rack Cabinet - Shock Pallet | AF012A | |
| 10636 G2 (36U) Rack Cabinet - Crated | AF013A | |
| 10636 G2 (36U) Rack Cabinet , with Extension - Shock Pallet | AF014A | |
| 10636 G2 (36U) Rack Cabinet, without door - Shock Pallet | AF015A | |
| 10636 G2 (36U) Rack Cabinet, with Extension, without door - Shock Pallet | AF016A | |
| NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed. | ||
| NOTE: Please
see the Rack 10000 G2 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html | ||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
|
HP Rack 10000 Series | 10642 (42U) Infrastructure Rack (Low Voltage) |
379006-001 |
| 10642 (42U) Infrastructure Rack (High Voltage) |
379005-001 | |
| HP Rack S10614 (14U) Rack Cabinet Shock Pallet |
292302-B22 | |
|
HP Rack 10842 (42U, 800mm wide) – Pallet |
257415-B21 | |
|
HP Rack 10842 (42U, 800mm wide) – Shock Pallet |
257415-B22 | |
|
HP Rack 10647 (47U) – Pallet |
245160-B21 | |
|
HP Rack 10647 (47U) – Crated |
245160-B23 | |
|
HP Rack 10642 (42U) – Pallet |
245161-B21 | |
|
HP Rack 10642 (42U) – Shock Pallet |
245161-B22 | |
|
HP Rack 10642 (42U) – Crated |
245161-B23 | |
|
HP Rack 10636 (36U) – Pallet |
245162-B21 | |
|
HP Rack 10636 (36U) – Shock Pallet |
245162-B22 | |
|
HP Rack 10636 (36U) – Crated |
245162-B23 | |
|
HP Rack 10622 (22U) – Pallet |
245163-B21 | |
|
HP Rack 10622 (22U) – Shock Pallet |
245163-B22 | |
|
HP Rack 10622 (22U) – Crated |
245163-B23 | |
|
NOTE: xxxxxx-B21 (pallet) used to ship empty racks shipped on a truck. -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). xxxxxx-B23 (crated) used for air shipments of empty racks. |
| |
| NOTE: Please
see the Rack 10000 QuickSpecs for Technical Specifications such as height, width,
depth, weight, and color: |
| |
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. |
| |
|
| ||
| Keyboards and Monitors | TFT7210R Rack Mounted 17"
Monitor NOTE: For a complete list of Monitors please view the following URL: http://www.hp.com/go/kvm. |
348373-B21
|
| TFT7600RKM |
AG052A
|
|
| 1U Rack Keyboard & Drawer
(Carbon) |
257054-001
|
|
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
|
||
| HP KVM Switch Options | IP Console Switch Box (KVM/IP), 3 x 1 x 16 |
262586-B21
|
| IP Console Switch Box (KVM/IP), 1 x 1 x 16 |
262585-B21
|
|
| Server Console Switch (KVM), 0 x 1 x 8 port |
336044-B21
|
|
| Server Console Switch (KVM), 0 x 2 x 16 port |
336045-B21
|
|
| PS/2 Interface Adapter, 1 pack |
262588-B21
|
|
| PS/2 Interface Adapter, 8 pack |
262587-B21
|
|
| USB Interface Adapter, 1 pack |
336047-B21
|
|
| Serial Interface adapter - 1 Pack with power supply |
373035-B21
|
|
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x 4 USB/PS2 KVM Switch, TT |
371301-D71
|
|
| HP 1x 4 USB/PS2 KVM Switch, RM |
371302-B21
|
|
| HP PS2 KVM Cable with audio, 6', 2-pack |
371730-B21
|
|
| HP USB KVM Cable with audio, 6', 2-pack |
371729-B21
|
|
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
|
HP Serial Console Server Options |
HP 16 Port Serial Console Server |
AF101A
|
| HP 48 Port Serial Console Server |
AF102A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack |
AF103A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack |
AF110A
|
|
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| Service and Support Offerings (HP Care Pack Services) |
|
|||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
|
|
Memory
| HP ProLiant DL760 G2 2.2 GHz/2MB or 2.0 GHz/1MB, 2048MB (4P) |
|
Standard Memory Standard
Memory Plus Optional Memory Standard
Memory Replaced with Optional Memory NOTE: 8 slots per Hot-Plug RAID Memory Cartridge. Up to 64 GB addressable memory total. Memory must be added in banks of two DIMMs per cartridge across all five (four if running in a non-redundant mode) Hot-Plug RAID Memory Cartridges. Charts do not represent all possible configurations. |
|
Memory |
Slot |
||||||||
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
||
|
Cartridge 1 (C1) |
Standard |
256 MB |
256 MB |
empty |
empty |
empty |
empty |
empty |
empty |
|
Optional |
256 MB |
256 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
| Maximum |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Cartridge 2 (C2) |
Standard |
256 MB |
256 MB |
empty |
empty |
empty |
empty |
empty |
empty |
|
Optional |
256 MB |
256 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Maximum |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Cartridge 3 (C3) |
Standard |
256 MB |
256 MB |
empty |
empty |
empty |
empty |
empty |
empty |
|
Optional |
256 MB |
256 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Maximum |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Cartridge 4 (C4) |
Standard |
256 MB |
256 MB |
empty |
empty |
empty |
empty |
empty |
empty |
|
Optional |
256 MB |
256 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Maximum |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Cartridge 5 (C5) |
Standard |
256 MB |
256 MB |
empty |
empty |
empty |
empty |
empty |
empty |
|
Optional |
256 MB |
256 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Maximum |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Following are memory options available from HP: |
|
|
317093-B21 |
|
236854-B21 |
|
236853-B21 |
|
236852-B21 |
| HP ProLiant DL760 G2 3.0 GHz/4MB, 2.7 GHz/2MB, 2.5 GHz/2MB or 2.8 GHz/2MB 4096MB (4P) |
| Standard Memory Standard
Memory Plus Optional Memory Standard Memory Replaced with Optional
Memory NOTE: 8 slots per Hot-Plug RAID Memory Cartridge. Up to 64 GB addressable memory total. Memory must be added in banks of two DIMMs per cartridge across all five (four if running in a non-redundant mode) Hot-Plug RAID Memory Cartridges. Charts do not represent all possible configurations. |
|
Memory |
Slot |
||||||||
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
||
|
Cartridge 1 (C1) |
Standard |
512 MB |
512 MB |
empty |
empty
|
empty
|
empty
|
empty
|
|
|
Optional |
512 MB |
512 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
| Maximum |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Cartridge 2 (C2) |
Standard |
512 MB |
512 MB |
empty
|
empty
|
empty
|
empty
|
empty
|
|
|
Optional |
512 MB |
512 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Maximum |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Cartridge 3 (C3) |
Standard |
512 MB |
512 MB |
empty
|
empty
|
empty
|
empty
|
empty
|
|
|
Optional |
512 MB |
512 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Maximum |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Cartridge 4 (C4) |
Standard |
512 MB |
512 MB |
empty
|
empty
|
empty
|
empty
|
empty
|
|
|
Optional |
512 MB |
512 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Maximum |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Cartridge 5 (C5) |
Standard |
512 MB |
512 MB |
empty
|
empty
|
empty
|
empty
|
empty
|
|
|
Optional |
512 MB |
512 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Maximum |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
|
Following are memory options available from HP: |
|
|
317093-B21 |
|
236854-B21 |
|
236853-B21 |
|
236852-B21 |
|
|
Storage
|
0 - 3 | Ultra320 SCSI Hot Plug drive bays |
|
A | Integrated 1.44MB Diskette drive | |
|
B | Integrated Slimline CD/DVD-ROM Drive (8X/24X) | |
|
Drive Support |
||||
|
|
||||
|
Quantity |
Position |
|
||
|
Integrated Media |
||||
|
Integrated 1.44-MB Diskette Drive |
Up to 1 |
A |
Integrated |
|
|
Integrated Slimline CD/DVD-ROM Drive (8X/24X) |
Up to 1 |
B |
Integrated IDE |
|
|
|
||||
|
Hard Drives |
||||
| Ultra320 Hot Pluggable Drives | ||||
|
Quantity |
Position |
|
||
| 300GB U320 10K 146.8GB U320 10K 72.8GB U320 10K 146.8GB U320 15K 72.8GB U320 15K 36.4GB U320 15K |
Up to 4 |
0-3 |
Integrated 5i Smart Array Controller |
|
| NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. | ||||
|
|
||||
|
External Storage |
||||
|
Quantity |
Position |
|
||
| Modular Smart Array 20 Family
|
1 per SCSI VHDCI connector | External | Smart Array 6402/128 Controller Smart Array 6404/256 Controller |
|
|
Modular Smart Array 30 Family |
Up to 13 |
External |
Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 642 Controller 64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
| Modular Smart Array 500 G2 System | 1 | External | Please see the Modular Smart Array 500 QuickSpecs for the latest list of supported HBAs: http://www.hp.com/go/msa500 | |
| Modular Smart Array 1000 | Please see the Modular Smart Array 1000 QuickSpecs below to determine configuration requirements | External | Please see the Modular Smart Array 1000 QuickSpecs (URL below) for the latest list of supported HBAs | |
| Modular Smart Array 1500 cs | Please see the Modular Smart Array 1500 cs QuickSpecs below to determine configuration requirements | External | Please see the Modular Smart Array 1500 cs QuickSpecs (URL below) for the latest list of supported HBAs | |
| Modular Smart Array 1000: http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html Modular Smart Array 1500 cs: http://www.hp.com/go/MSA1500cs |
||||
|
|
||||
|
Maximum Storage Capacity - (SCSI Attached) | ||
| Internal |
1.20TB (4 x 300 GB Ultra320) | |
| External | 184.8TB hot plug SCSI storage (44 x (14 x 300 B Ultra320)) | |
| Total |
186.0TB | |
| | ||
| Tape Drives, Tape Autoloaders, & Tape Libraries | ||||
|
NOTE: For an up-to-date listing of the latest O/S Support details for
each of the Tape Drives listed below, please see the following: NOTE: For an up-to-date listing of the latest O/S Support details
for each of the Tape Autoloaders & Tape Libraries listed below, please see
the following: NOTE: For complete listing of tape drive offerings see http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html | ||||
| Quantity Supported |
Position Supported |
Controller | ||
| HP
StorageWorks Tape Drives, Hot Plug DAT 24 USB DAT 40 USB DAT 72 USB | 1 |
0-3 | Smart
Array 5i Controller (integrated on system board) 64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS | |
| HP StorageWorks Tape Drives,
USB External DAT 40 USB DAT 72 USB |
1 per USB port |
External | USB port | |
| HP StorageWorks Tape Drives,
External Ultrium 230 Ultrium 232 Ultrium 448 Ultrium 460 DAT 40 DAT 72 DLT VS80 DLT VS160 SDLT 320 |
Up to 2 |
External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS | |
| HP StorageWorks Tape Drives,
External Ultrium 960 SDLT 600 |
1 per SCSI Channel |
External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS | |
| HP StorageWorks Autoloaders,
External DAT 72x6 Tape Autoloader 1/8 Tape Autoloader |
1 autoloader per SCSI channel |
External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS | |
| HP StorageWorks Rack-mount
Tape Drive Enclosures 1U Rack-Mount Kit 3U Rack-Mount Kit 5U Rack-Mount Kit | 1
per SCSI channel | External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS | |
| HP StorageWorks Tape Libraries,
External MSL2024 (Ultrium 448 and 960-based) MSL4048 (Ultrium 448 and 960-based) MSL6000 (Ultrium 960 and 460-based) MSL6000 (SDLT 600-based) MSL5026S2 (SDLT 320-based) MSL5052S2 (SDLT 320-based) |
Please reference the MSL Tape Library QuickSpecs to determine
configuration requirements |
External | Please consult the EBS connectivity matrix at http://www.hp.com/go/ebs for detailed connectivity information. | |
|
|
Technical Specifications
|
System Unit | Dimensions (HxWxD) | 12.14 x 17.5 x 27 in (30.83 x 44.45 x 68.58 cm) | |
|
Weight | 165 lb (75 kg) | ||
|
No hard drives installed, | |||
|
Input Requirements |
Rated Input Voltage |
100 to 120 VAC/200 to 240 VAC | |
|
Rated Input Frequency |
47 to 63 Hz (lowline/highline) | ||
| Input Power |
740W/1700W (lowline/highline) | ||
| Rated Input Current | 8A at 100 VAC/10A at 200 VAC | ||
|
BTU Rating |
1555 Watts [5309 BTU/hr] | ||
| Power Supply Output Power (per power supply) |
Rated Steady-State Power |
500W/1150W (lowline/highline) | |
|
Maximum Peak Power |
540W/1150W (lowline/highline) | ||
| Temperature Range | Operating |
50° to 95° F at sea level, altitude de-rating of 1.8° F per 1,000 ft to 10,000 ft (10° to 35° C at sea level, altitude de-rating of 1°C per 300 m to 3,000 m). Maximum rate of change is 18°F/Hr (10°C/Hr) | |
| Non-operating |
-22° to 140 ° F (-30° to 60° C). Maximum rate of change is 36° F/Hr (20° C/Hr) | ||
|
Shipping | -22° to 122° F (-30° to 50° C) | ||
|
Relative Humidity |
Operating | 10 to 90% relative humidity, 82.4°F (28°C) maximum wet bulb temperature, non-condensing | |
| Non-operating |
5 to 95% relative humidity, 101.7°F (38.7°C) maximum wet bulb temperature, non-condensing | ||
|
Maximum Wet Bulb Temperature |
101.7° F (38.7° C) | ||
| Acoustic Noise |
Idle | ||
|
6.9 | ||
|
53 | ||
| | |||
|
Power Supply | 1150/500W, Hot Plug Redundant (2 standard) |
One Redundant Power Supply | |
| Input Specifications | Normal Line Voltage | 100 to 120 VAC/200 to 240 VAC | |
| Range Input Line |
90 to 132 VAC/180 to 265 VAC | ||
| Frequency Range |
47 to 63 Hz | ||
| Power Factor |
0.95 | ||
|
Input Current | 8 A at 100 VAC/10 A at 200 VAC | ||
| Inrush Current |
<70 A at 132 VAC (cold start) | ||
| Holdup Time |
20 ms from zero crossing at 120 VAC | ||
|
General Specifications |
Full Output Rating | To 104° F (40° C) and 5,000 ft (1524 m) | |
|
To 89.6° F (32° C) and 10,000 ft (3,048 m) | |||
|
Minimum Load | 1 A on
5 V output; 1 A on 12 V output; | ||
| Ambient Temperature Range | Operating |
41° to 122° F (5° to 50° C) | |
|
Storage | -40° to 185° F (-40° to 85° C) | ||
|
Dielectric Voltage Withstand |
Input to Output | 3,000 VAC/min | |
| Input to Ground | 1,500 VAC/min | ||
| Input Transient Susceptibility | Common and Differential Mode (superimposed on AC line) |
2,500 V, 1µs, damped sinusold 600 V, 10 µs pulse | |
|
Differential Mode | 20% step change in AC input voltage | ||
|
| |||
| Slimline CD/ DVD-ROM Combo Drive (8X/24X) |
Shipping Dimensions | 13.88 x 11.38 x 9.25 in (35.26 x 28.91 x 23.50 cm) | |||
| Shipping Weight | 5 lb (2.27 kg) | ||||
| Disk | Applicable Disk | DVD-R (Read Only) | |||
| 2.6 GB/side DVD-RAM (Read Only) | |||||
| 5.2 GB/side DVD-RAM (Read Only) | |||||
| CD-ROM Mode-1 data disc | |||||
| CD-ROM Mode-2 data disc | |||||
| CD Audio disc | |||||
| CD-Extra | |||||
| CD-ROM | |||||
| CD-R | |||||
| CD Text | |||||
| PhotoCD | |||||
| CD-I (mode 2) | |||||
| CD-I Ready | |||||
| CD-Bridge | |||||
| Capacity | DVD-ROM | DVD-SL | 4.7 GB/side | ||
| DVD-DL | 8.5 GB/side | ||||
| Double Sided | 9.40 GB/side | ||||
| DVD-R | 3.95 GB/side | ||||
| DVD-RAM | 2.6 GB/side and 5.2 GB/ | ||||
| CD-ROM | Mode-1 | 650 MB (550 MB) | |||
| Mode-2 | 742 MB (640 MB) | ||||
| Block Size | DVD | 2,048 bytes | |||
| CD | 2,352 (Mode-0) | ||||
| 2352, 2340, 2336, 2048 bytes (Mode-1) | |||||
| 2352, 2340, 2336, 2048 bytes (Mode-2) | |||||
| Diameter | 120 mm, 80 mm (with adapter at vertical mounting mode) | ||||
| Loading Mechanism | Tray type | ||||
| Interface | EIDE (ATAPI) | ||||
| Access Times (typical) | Random | DVD-ROM < 120 ms, CD-ROM < 110 ms | |||
| Full-Stroke | DVD-ROM < 240 ms, CD-ROM < 160 ms | ||||
| Audio Output Level (typical) | Line-out | CD 0.7 Vrms at 47 Kohms Load | |||
| Data Transfer Rate | DVD-ROM | Single Layer | 10.8 MB/sec. Max. | ||
| DVD-RAM | 2.77 MB/sec. Maxz | ||||
| CD-ROM | 7.2 MB/sec. Max. | ||||
| Cache Buffer | 2 MB | ||||
| Spin-up Time (typical) | less than 10 seconds | ||||
| MTBF | 120,000 Power On Hours (POH) | ||||
| Ambient Temperature | Operating | -22° to 140° F (-30° to 60° C) | |||
| Relative Humidity | Operating | 10% to 80% | |||
| Storage/ | 5% to 95% | ||||
| Dimensions | (HxWxD, maximum) | 0.5 x 5.04 x 5.1 in (12.7x128x129.4 mm) | |||
| Option Kit Contents | DVD-ROM drive with installation guide, warranty card, registration card | ||||
| | |||||
|
Smart Array 5i Controller (integrated on system board) |
Protocol |
Wide Ultra3 SCSI |
|
Processor |
32-bit RISC |
|
|
XOR engine |
Hardware RAID |
|
|
Electrical interface |
Low Voltage Differential (LVD) |
|
|
Simultaneous Drive Transfer Channels |
2 |
|
|
Channel Transfer Rate |
320 MB/s total; 160 MB/s per channel |
|
|
SCSI Port Connectors |
One external and one internal SCSI port |
|
|
Memory |
32 MB of DRAM used for code, transfer buffers, and non-battery-backed read cache |
|
|
Peak transfer rate |
160 MB/s |
|
|
Logical Drives Supported |
32 |
|
|
Software Upgradeable Firmware |
Yes |
|
|
RAID Support |
RAID 5 (Distributed Data Guarding |
|
|
RAID 1+0 (Striping and Mirroring) |
||
|
RAID 1 (Mirroring) |
||
|
RAID 0 (Stripping) |
||
|
Disk Drive and Enclosure Protocol Support |
Ultra2 and Ultra3 |
|
|
|
||
| NC7170 Dual-Port PCI-X 1000T Gigabit Server Adapter | Network Interface | Two 10/100/1000-T ports | |
| Compatibility | IEEE 802.3 10Base-T | ||
| IEEE 802.3ab 1000Base-T | |||
| IEEE 802.3u 100Base-TX | |||
| IEEE 802.3ad, IEEE 802.3p, and IEEE 802.3Q | |||
| Data Transfer Method | 64-bit/133MHz PCI-X, compatible with 64/100, 64/66, 64/33 and 32/33 | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-T (Half and Full-Duplex) | 2000 Mb/s | ||
| Connector | Two RJ-45 | ||
| Cable Support | 10Base-T | Category 3,4 or 5 UTP; up to 328 ft (100 m) |
|
| 10/100/1000Base-T | Category 5 UTP (2 pair); up to 328 ft (100 m) |
||
|
|
|||
| © Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |