Overview
HP AlphaServer TS15
|
||||||||||||||||||||||||||||||||||||||||
| At A Glance |
| AlphaServer TS15 NEBS-Certified 3U System includes: |
|
|
|
Standard Features
| Processor | Alpha 21264A 1-GHz processor | ||
|
|
|||
| Cache Memory | 2-MB onboard cache | ||
|
|
|||
| Upgradability | Supports upgrades of memory and hard drives | |
| Standard | One CPU | |
|
|
||
| Memory | Standard | 512 MB (one memory kit), 1 GB (one memory kit), or 2 GB (one memory kit) - Tru64 UNIX, OpenVMS | |
| Maximum | 4 GB (two memory kits, each kit includes two industry-standard DIMMs with ECC support) | ||
|
|
|||
| Network Controller | Onboard dual 10/100 BaseT Ethernet ports |
|
|
|
| Expansion | Storage bays | Internal Storage Cage Systems: Four
total - DVD/CD-RW (standard) and three storage bays, three internal 3.5-inch
x 1-inch hard disk drives or two internal 3.5-inch x 1-inch hard disk drives
and one 5.25-inch x 1.6-inch removable media device Front Access Storage Cage Systems: Five Total - DVD/CD-RW (standard) and four storage bays, two front access 3.5-inch x 1-inch hard disk drives and two internal 3.5-inch x 1-inch hard disk drives) or one 5.25-inch x 1.6-inch removable media device and two internal 3.5-inch x 1-inch hard disk drives |
| PCI slots | Four full-length 64-bit/33-MHz slots or two full length 64-bit/66-MHz slots | |
|
|
||
| Storage | DVD/CD-RW |
Internal Storage Cage Systems:
5.25-inch half height DVD/CD-RW drive (standard) Front Access Storage Cage Systems: 24X slim-line DVD/CD-RW drive (standard) |
|
| Hard Drives | 36.4-GB and 72.8-GB Wide Ultra3 available with the Internal Storage Cage, 36.4-GB, 72.8-GB, or 146-GB Universal SCSI drives available with Front Access Storage Cage (10K rpm and 15K rpm available) | ||
|
|
|||
| Storage Adapter/ Controller |
Onboard Ultra160 dual-port SCSI controller, one port for internal storage and one port for external storage, plus choice of optional storage adapters/controllers (see Step 9) |
|
|
|
| Expansion Ports | SCSI | One Ultra160 | |
| Serial | Two ports, one serial port with full-duplex asynchronous modem control and one RMC dedicated serial port with full-duplex asynchronous modem control | ||
| Keyboard | One PS/2-style port | ||
| Mouse | One port | ||
|
|
|||
| Power Supply | 400W (-48VDC) |
|
|
|
| Manageability | Hewlett-Packard Insight Manager |
|
|
|
| OS Support | AlphaServer TS15 Tru64 UNIX systems include pre-installed software (V5.1B, PK3, New Hardware Delivery-8 (NHD-8), Base license, Unlimited User license, Server Extension license, Internet Express and Hewlett-Packard Secure Web Server |
| AlphaServer TS15 OpenVMS systems include pre-installed software (V7.3-1), Base license with System Manager license and Enterprise Integration Server License Package for OpenVMS | |
| Minimum OS support: Tru64 UNIX V5.1B, PK3 New Hardware Delivery-8 (NHD-8) or OpenVMS V7.3-1 plus TIMA kit | |
|
|
|
| Service and Support | Protected by HP Services, including a one-year, on-site hardware warranty with next business day response. Software warranty is a 90-day telephone advisory. Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support. |
|
|
Systems
| Step 1 Select system |
|
|
| AlphaServer TS15 1-GHz systems require the mandatory selection of the following items: |
|
|
AlphaServer TS15 1-GHz Base Systems |
|||||||
|
OS |
CPU |
Memory |
PCI |
2-10/100t Ethernet Ports |
Hard Drive |
Storage Cage |
Order Number |
| Tru64 UNIX | 1 GHz | Mandatory | 4 | Onboard | Mandatory | Mandatory | DA-T15BA-AA |
| OpenVMS | 1 GHz | Mandatory | 4 | Onboard | Mandatory | Mandatory | DY-T15BA-AA |
|
|
|||||||
| Step 2 Memory - Mandatory | |
|
|
|
|
| 512-MB memory kit, two 200-pin, 133-MHz, 256-MB DIMMs |
3X-MS315-EA
|
|
| 1-GB memory kit, two 200-pin, 133-MHz, 512-MB DIMMs |
3X-MS315-FA
|
|
| 2-GB memory kit, two 200-pin, 133-MHz, 1-GB DIMMs |
3X-MS315-GA
|
|
|
|
||
| Step 3 - Select Storage Cage - Mandatory | ||
|
|
||
![]() |
||
|
|
3X-BA15A-AA
|
|
3X-BA15B-AA
|
| Step 3a - Internal Storage Cage | ||||||||||||
|
|
||||||||||||
![]() |
||||||||||||
|
||||||||||||
| Step 3b - Front Access Storage Cage |
|
|
|
![]() |
| 1. Internal drive bay | |
| 2. DVD/CD-RW | |
| 3. Front accessible drive bay | |
| 4. Front accessible drive bay | |
| 5. Internal drive bay |
|
TS15 Storage Configuration Rules with Selection of Internal Storage Cage: |
|
|
|
| Step 4 - Mandatory Selection of Disk Drive | ||
|
|
||
| Internal SCSI
Disk Drives (For Drives Internal to System Enclosure) |
36.4-GB 10,000 rpm Ultra3 SCSI drive |
DS-RZ3FD-WA
|
| 72.8-GB 10,000 rpm Ultra3 SCSI drive | DS-RZ3GA-WA | |
|
|
||
| Internal SCSI
Disk Drives (For Internal Storage Cage) |
36.4-GB 10,000 rpm Ultra3 SCSI drive | DS-RZ3FD-WA |
| 72.8-GB 10,000 rpm Ultra3 SCSI drive | DS-RZ3GA-WA | |
|
|
||
| Universal Disk
Drives (For Front Access Storage Cage) |
18.2-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive | 3R-A3848-AA |
| 36.4-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive | 3R-A3838-AA | |
| 36.4-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive | 3R-A3849-AA | |
| 72.8-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive | 3R-A3839-AA | |
| 72.8-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive | 3R-A3851-AA | |
| 146-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive | 3R-A3841-AA | |
| 300-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive | 3R-A4952-AA | |
|
|
Options
| Step 5 - NEBS-Certified Options | ||
|
|
||
|
Internal/External Tapes |
DAT72 internal tape drive kit
(Q1525A) |
3R-A4544-AA
|
| DAT72 external tape drive kit,
U.S. (Q1527) |
3R-A4545-AA
|
|
| DAT72 external tape drive kit,
International (Q1528) |
3R-A4546-AA
|
|
| DAT72 hot-plug tape drive kit
(Q1529) |
3R-A4547-AA
|
|
| Optional 48X half-height DVD/CD-RW combo, carbon black; supported in Internal Storage Cage only not supported in Front Access Storage Cage |
3X-A4412-BA
|
|
|
|
||
| Universal Disk
Drives (For Front Access Storage Cage) |
36.4-GB Ultra320 SCSI 10,000 rpm
1-inch Universal Disk Drive |
3R-A3838-AA
|
| 36.4-GB Ultra320 SCSI 15,000 rpm
1-inch Universal Disk Drive |
3R-A3849-AA
|
|
| 72.8-GB Ultra320 SCSI 10,000 rpm
1-inch Universal Disk Drive |
3R-A3839-AA
|
|
| 72.8-GB Ultra320 SCSI 15,000 rpm
1-inch Universal Disk Drive |
3R-A3851-AA
|
|
| 146-GB Ultra320 SCSI 10,000 rpm 1-inch Universal Disk Drive |
3R-A3841-AA
|
|
|
|
||
| Internal SCSI Disk
Drives (For Drives Internal to System Enclosure) |
36.4-GB 10,000 rpm Ultra3 SCSI
drive |
DS-RZ3FD-WA
|
| 72.8-GB 10,000 rpm Ultra3 SCSI
drive |
DS-RZ3GA-WA
|
|
|
|
||
| StorageWorks Shelves Supported in NEBS Series Cabinets with/without Front Doors | 14-slot model 4414R Ultra320 one-bus shelf, -48VD NEBS |
3X-NS32R-TA
|
| 14-slot model 4454R Ultra320 two-bus shelf, -48VD NEBS |
3X-NS32R-TB
|
|
|
|
||
| 1U IPFM Alarm Panel Single Unit | The Intelligent Peripheral Fault
Manager (IPFM) is the fault management component of the AlphaServer Intelligent
Peripheral (IP) Platform that provides a full suite of voice, communications,
management, processing, and storage resources that can be accessed and controlled
by software running on the platform. The AlphaServer Intelligent Peripheral
Platform is intended for use in telecommunications networks and environments,
supporting real-time communications services and applications.
Complete assembly with one control unit -- Capable of monitoring four
AlphaServers. |
2T-IPF1U-01
|
|
|
||
| FRU 1U Alarm Module Replacement Unit | Module upgrade for a second unit or FRU |
2T-IPF1U-00
|
|
|
||
| Cable - used to connect PCI Adapter to Unit | Cable Assembly, CI BUS, ASIP2 (cable is supplied with 2T-IPF1U-00) |
17-04675-01
|
|
|
||
| Maximum # Supported |
|
||
|
PCI Adapters
|
Tru64 UNIX | OpenVMS |
|
|
PCI Fault Management Control Module (IPFM V3.0A) - one
adapter per system
|
1 | 0 |
3X-KPCON-AA
|
|
PCI 1-port Ultra2 SCSI (LVD) single-ended adapter, 68-pin
HD connector, requires BN38C cable (2 to 20 meters) to connect to single-ended
UltraSCSI shelf
|
2 | 2 |
3X-KZPCA-AA
|
|
PCI 2-channel LVD multi-mode Ultra3 SCSI adapter, VHDCI,
requires use of Ultra160 SCSI cables. NOTE:
No SDLT tape/library support.
|
2 | 2 |
3X-KZPEA-DB
|
|
Ultra160 SCSI cables
xx=02 for 6 feet, 03 for 12 feet, 04 for 24 feet |
3X-BC56J-xx
|
||
|
PCI 1-port UltraSCSI differential adapter; includes external
68-pin HD connector; requires BN38C-xx cable (2-25 meters) to connect
adapter to Differential UltraSCSI shelf or RAID controller.
NOTE: Internal connection is not supported. |
2 | 2 |
3X-KZPBA-CC
|
|
68-pin HD male-to-VHDCI male UltraSCSI cable; required
for each external UltraSCSI shelf attached to KZPBA-CA/CB adapter
|
BN38C-xx
|
||
|
PCI (32-/64-bit, 33-/66-MHz) dual-port 10/100 Ethernet
(UTP/RJ45s) NIC and Base Module. (One 3X-DE602-TA or 3X-DE602-FA optional
add-on daughter card can be combined with this module.) Maximum two per
system, maximum ten 10/100 Ethernet ports per system. Use BN25G, BN26M,
BN24Q, or BN28Q twisted pair RJ45 cables. NOTE:
Two 10/100 Ethernet ports included with TS15 system.
|
2 | 2 |
3X-DE602-BB
|
|
Dual-port 10/100 Ethernet (UTP/RJ45) add-on daughter card for use with the 3X-DE602-BB only. The combined 3X-DE602-BB and 3X-DE602-TA modules provide four 10/100 (UTP/RJ45s) ports in a single PCI slot option and allow a maximum of 16 ports per system. Maximum two per system, maximum ten 10/100 Ethernet ports per system. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. NOTE: The 3X-DE602-TA cannot be used standalone.
NOTE: Two 10/100 Ethernet ports included with TS15 system. |
2 | 2 |
3X-DE602-TA
|
|
IN7 Connectivity --- HP 4 P E1/T1/J1 ATM UN
|
4 | 4 |
DNBE1-AQ
|
|
IN7 Connectivity --- Low Perf 4 P EI/T1/J1/ATM
|
4 | 4 |
DNBE1-BQ
|
|
Quad T1 ISDN W-96 Channel Voice Card
|
4 | 4 |
2T-VCQQU-US
|
|
Quad E1 ISDN IFC 120 Channel Voice Card
|
4 | 4 |
2T-VCQQF-EU
|
|
NOTE: For more
information on the above products, see http://www.hp.com/communications/opencall
NOTE to SALES: For ordering and configuration assistance on the above products, see http://ocbu-bid.corp.hp.com/index.htm |
|
1-port PCI-X/PCI to 10/100/1000 UTP Ethernet NIC
|
2 | 2 |
3X-DEGXA-TB
|
|
ATI RADEON 7500 64-MB PCI 2D/3D Graphics Accelerator plus
ATI RADEON NEBS kit
NOTE: Slot 0 must be used for this configuration. |
1 | 1 |
3X-PBXGG-TA
|
|
Memory Channel Adapter, 5.0/3.3 PCI-to-Memory Channel
II compatible
|
2 | 2 |
CCMAB-BA
|
|
|
||||
| Step 6 - Tape Drives - Optional - Non-NEBS Qualified | ||
|
|
||
| Internal Tape Drives | DAT 36/72-GB DDS5 tape drive |
3R-A4544-AA
|
| DAT 20/40-GB tape drive, LVD, carbon black |
3R-A4752-AA
|
|
|
|
||
| Universal Tape
Drives (For Front Access Storage Cage) |
DAT 36/72-GB DDS5 Universal tape drive |
3R-A4547-AA
|
| DAT 20/40-GB Universal tape drive, LVD, uses two slots |
3R-A4745-AA
|
|
|
|
||
| Step 7 - DVD-ROM Drive - Optional | ||
|
|
||
| Half-height DVD/CD-RW combo, carbon black - Supported in Internal Storage Cage only - not supported in Front Access Storage Cage. |
3R-A4412-AA
|
|
|
|
||
| Step 8 - NEBS Cabinet |
|
|
| Step 8a - Cabinets - Optional |
|
|
|
| Cabinet Configuration Chart for AlphaServer TS15 Rackmount Systems |
|
| Cabinet Configuration Chart for AlphaServer TS15 (3U) Rackmount Systems with Disk Shelves (3U) |
|
NEBS Cabinet
|
System Rack Kit per TS15 system
|
NEBS Cabinet Height/Space
|
TS15 Systems
|
StorageWorks
3X-NS32R-XX Disk Shelves |
| 3X-H9705-AB |
Included
|
40U carbon black
|
1 or 2
|
6
|
|
3X-H9705-BB |
Included
|
37U carbon black/ without front door
|
3 or 4
|
6
|
| 34-56433-07 |
Included
|
37U sable gray/with front door
|
5
|
6
|
| 3X-H7603-AB |
Power distribution unit
|
Maximum 6 with redundancy
|
| NOTE: Power cord
included with system kernel. If customization is required contact HP Services. Additional PDU may be required if additional TS15 systems or storage arrays are configured. |
||
|
|
||
| StorageWorks Shelves
Supported in NEBS series Cabinets with/ without Front Doors |
14-slot Model 4414R Ultra320 one bus, -48VD NEBS |
3X-NS32R-TA
|
| 14-slot Model 4454R Ultra320 two bus, -48VD NEBS |
3X-NS32R-TB
|
|
|
|
| Step 9 - External Storage - Optional |
|
|
| Storage Controllers/Host Bus Adapters for StorageWorks Pedestals and Shelves | ||
|
|
||
|
||
| Maximum # Supported |
|
||
| Tru64 UNIX | OpenVMS |
|
|
|
PCI/PCI-X to 2-Gb Fibre Channel adapter, 64-bit/133 MHz,
single-channel (302784-B21) PCI V2.2 compatible
|
2 | 2 |
DS-KGPSA-EA
|
|
Fibre Channel cable
|
BNGBX-xx
|
||
|
PCI 1-port Ultra2 SCSI (LVD) single-ended adapter, 68-pin
HD connector, requires BN38C cable (2 to 20 meters) to connect to single-ended
UltraSCSI shelf
|
2 | 2 |
3X-KZPCA-AA
|
|
68-pin HD male-to-VHDCI male UltraSCSI cable; required
for each external UltraSCSI shelf attached to KZPCA-AA adapter
|
BN38C-xx
|
||
|
PCI 2-channel LVD multi-mode Ultra3 SCSI adapter, VHDCI,
requires use of Ultra160 SCSI cables. NOTE:
No SDLT tape/library support.
|
2 | 2 |
3X-KZPEA-DB
|
|
Ultra160 SCSI cables, xx=02 for 6 feet, 03 for 12 feet,
04 for 24 feet
|
3X-BC56J-xx
|
||
|
PCI 1-port UltraSCSI differential adapter; includes external
68-pin HD connector; requires BN38C-xx cable (2-25 meters) to connect
adapter to Differential UltraSCSI shelf or RAID controller. NOTE:
Internal connection is not supported.
|
2 | 2 |
3X-KZPBA-CC
|
|
68-pin HD male-to-VHDCI male UltraSCSI cable; required
for each external UltraSCSI shelf attached to KZPBA-CA/CB adapter
|
BN38C-xx
|
||
|
PCI 2-port PCI to Ultra3, 64-bit, 66-MHz, LVD backplane
RAID controller with 128-MB cache (uses one PCI slot); requires connection
to DS-SL13R-xx shelves. Requires use of Ultra160 SCSI cables. NOTE:
Host-based volume shadowing or shared bus support not supported under
OpenVMS.
|
- | 2 |
3X-KZPDC-BE
|
|
PCI 4-port PCI to Ultra3, 64-bit, 66-MHz, LVD backplane RAID controller with 256-MB cache (uses one PCI slot); requires connection to DS-SL13R-xx shelves. Requires use of Ultra160 SCSI cables. NOTE: Host-based volume shadowing or shared bus support not supported under OpenVMS. |
- | 2 |
3X-KZPDC-DF
|
|
Ultra160 SCSI cables
xx=02 for 6 feet, 03 for 12 feet, 04 for 24 feet |
3X-BC56J-xx
|
||
| StorageWorks Fibre Channel Switches | NOTE:
For more information on the following switches, refer to http://h18000.www1.hp.com/products/quickspecs/10457_na/10457_na.html
NOTE: This Web site is available in English only. |
|
| Fibre Channel SAN Switch, 8-ports,
2-Gb, with Fabric Operating Software (322120-B21) BS |
DS-DSGGD-BC
|
|
| Fibre Channel SAN Switch, 8-ports,
2-Gb, with Fabric Operating Software (322121-B21) PP |
DS-DSGGD-CC
|
|
| Fibre Channel SAN Switch, 16-ports,
2-Gb, with Fabric Operating Software (322118-B21) |
DS-DSGGD-CA
|
|
| Fibre Channel SAN Switch, 16-ports,
2 Gb, with Fabric Operating Software, two power supplies (Tru64 UNIX and
OpenVMS) - requires Tru64 UNIX V5.1A patch kit: T64V51AB01AS0001-20020116.tar
(322119-B21) PP |
DS-DSGGD-CB
|
|
| Fibre Channel 2-Gb 32-port Core
Switch, with Fabric Operating software (240603-B21) BB |
DS-DSGGD-AB
|
|
| Fibre Channel 2-Gb 64-port Core
Switch, with Fabric Operating software (332177-B21) BS |
DS-DSGGE-BA
|
|
| Fibre Channel 2-Gb 64-port Core
Switch, with Fabric Operating software (322178-B21) DP |
DS-DSGGE-CA
|
|
|
|
||
| McData 64-port Fibre Channel SAN Director Class Switch | SAN Director 2 Gb, 64 ports (286809-B21)
|
DS-DMGGD-BA
|
| SAN Edge Switch 2 Gb, 24 ports
(316095-B21) |
DS-DMGGE-BD
|
|
| SAN Edge Switch 2 Gb, 140-ports
(316093-B21) |
DS-DMGGD-CA
|
|
| SAN Edge Switch 2 Gb, 32-ports
(286810-B21) |
DS-DHGGE-BC
|
|
| NOTE: Connection for, or between, 1-Gb and/or 2-Gb SAN switches require different cables. Refer to the Switches, Hubs, and Interconnects QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/north_america/10490.html. | ||
|
|
||
| Fibre Channel Disk Drives | 36-GB 10K rpm dual-port 2-Gb/sec
FC-AL 1-inch (25.4mm) drive (238590-B21) |
3R-A3239-AA
|
| 72-GB 10K rpm dual-port 2-Gb/sec
FC-AL 1-inch (25.4mm) drive (238921-B21) |
3R-A3260-AA
|
|
| 36-GB 15K rpm dual-port 2-Gb/sec
FC-AL 1-inch (25.4mm) drive (236205B21) |
3R-A3210-AA
|
|
| 72-GB 15K rpm dual-port 2-Gb/sec
FC-AL 1-inch (25.4mm) drive (293568-B21) |
3R-A3971-AA
|
|
| 146-GB 10K rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4mm) drive (293556-B21) |
3R-A3975-AA
|
|
|
|
||
| Step 10 - UltraSCSI RAID Array Controllers & UltraSCSI RAID Packaged Solutions - Optional | ||
|
|
| msa1000 | msa1000 SAN Storage Array (201723-B22) |
3R-A4328-AA
|
|
|
||||
| StorageWorks Disk Array Family | NOTE: The HP StorageWorks
Disk Array Family, specifically the XP128 and XP1024, are supported on AlphaServer
TS15 systems. For product and ordering information, refer to the following
Web pages: http://www.hp.com/products1/storage/products/disk_arrays/highend/xp1024/index.html
http://www.hp.com/products1/storage/products/disk_arrays/highend/xp128/index.html The following part numbers have been assigned for reference purposes only: |
|||
| 3R-A4417-AA | A7876A | XP128 Disk Array Control Frame | |
| 3R-A4418-AA | A7906A | XP1024 Disk Array Control Frame | |
|
|
|||
| Step 11 - Networks and Communications - Optional | |||
|
|
|||
|
|||
| Maximum # Supported |
|
||
| Tru64 UNIX | OpenVMS |
|
|
|
Ethernet 10/100
|
|||
|
Single-port 100Mbps (MMF/duplex-SC) add-on daughter card
for use with 3X-DE602-BB. The combined 3X-DE602-BB 3X-DE602-FA provides
two 10/100 (UTP/RJ45s) and one 100Mbps (MMF/SC) ports in a single PCI
slot option. Maximum two per system, maximum ten 10/100 Ethernet ports
supported per system. Use BN34A or BN34B cables. NOTE:
The 3X-DE602-TA cannot be used standalone. Two 10/100 Ethernet ports
included with TS15 system.
|
2 | 2 |
3X-DE602-FA
|
|
PCI (32-/64-bit, 33-/66-MHz) dual-port 10/100 Ethernet
(UTP/RJ45s) NIC and Base Module. (One 3X-DE602-TA or
3X-DE602-FA optional add-on daughter card can be combined with this module.) Maximum two per system, maximum ten 10/100 Ethernet ports per system. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. NOTE: Two 10/100 Ethernet ports included with TS15 system. |
2 | 2 |
3X-DE602-BB
|
|
Dual-port 10/100 Ethernet (UTP/RJ45) add-on daughter card for use with the 3X-DE602-BB only. The combined 3X-DE602-BB and 3X-DE602-TA modules provide four 10/100 (UTP/RJ45s) ports in a single PCI slot option; allows for a maximum of 16 ports per system. Maximum two per system, maximum ten 10/100 Ethernet ports per system. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. NOTE: The 3X-DE602-TA cannot be used standalone.
NOTE: Two 10/100 Ethernet ports included with TS15 system. |
2 | 2 |
3X-DE602-TA
|
|
Cable for 10BaseT twisted pair connection
|
BN25G-xx
|
||
|
Gigabit Ethernet
|
|||
|
1-port PCI-X/PCI to MMF Gbe NIC
|
2 | 2 |
3X-DEGXA-SA
|
|
1-port PCI-X/PCI to 10/100/1000 UTP Ethernet NIC
|
2 | 2 |
3X-DEGXA-TB
|
|
ATM
|
|||
|
PCI (32-bit, 33-MHz) to 155 Mbps ATM fiber NIC with SC
connector. Use BN34B-xx cable.
|
2 | 2 |
3X-DAPBA-FA
|
|
Asynchronous Communications (ASYNC)
|
|||
|
PCI (32-bit, 33-MHz) to quad-port Async Communications
NIC with DB-25 octopus cable
|
2 | 2 |
PBXDA-BA
|
|
PCI (32-bit, 33-MHz) to 8-port Async Communications NIC
with DB-25 octopus cables
|
2 | 2 |
PBXDA-BB
|
|
PCI 16-port asynchronous controller, cable included; maximum
three PBXDA-Ax per system
|
2 | 2 |
PBXDA-AC
|
|
PBXDA-AC Asynchronous Connector Adapters
|
|||
|
RJ45 to DB-25 converter cable
|
CXI01-AC
|
||
|
RJ45 to DEC MJ11 converter cable (8 pack)
|
CXI01-AF
|
||
|
Synchronous Communications (SYNC)
|
|||
|
PCI (32-bit, 33-MHz) to dual-port intelligent synchronous
communications NIC. Requires at least one (maximum two) BN34x synchronous
cable listed below.
|
2 | 2 |
3X-PBXDD-AA
|
|
PCI (32-bit, 33-MHz) to quad-port intelligent synchronous
communications NIC. Requires at least one (maximum four) BN34x synchronous
cable listed below.
|
2 | 2 |
3X-PBXDD-AB
|
|
Synchronous-Specific Cables
|
||
|
EIA-530 single-port cable
|
3X-BC34G-06
|
|
|
V.24/EIA-232 single-port cable
|
3X-BC34L-06
|
|
|
V.11/x.21 single-port cable
|
3X-BC33S-06
|
|
|
V.35 single-port cable
|
3X-BC34T-06
|
|
|
Ethernet, FDDI, ATM Multi-use Cables
|
||
|
Multimode fiber optic (MMF) 62.5/125um duplex cable, with
SC-to-ST connectors.
xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, 30 meters |
BN34A-xx
|
|
|
Multimode fiber optic (MMF) 62.5/125um duplex cable, with
SC-to-SC connectors.
xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, 30 meters |
BN34B-xx
|
|
|
Category 5e (4-Unshielded Twisted Pairs / UTP) straight-through
cable with RJ45-to-RJ45 connectors for system to switch, repeater, or
hub connectivity.
xx = available lengths: (0B, 0E, 01, 03, 04, 07) for 0.2, 0.5, 1, 3, 4, 7 meters |
BN25G-xx
|
|
|
Category 5e (4-Twisted Pairs, Screened/ ScTP) straight-through
cable with RJ45-to-RJ45 connectors for system to switch, repeater, or
hub connectivity.
xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, 7 meters |
BN26M-xx
|
|
|
Category 5e (4-Unshielded Twisted Pairs / UTP) Xover cable
with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity.
xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, 7 meters |
BN24Q-xx
|
|
|
Category 5e (4-Twisted Pairs, Screened / ScTP) Xover cable
with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity.
xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, 7 meters |
BN28Q-xx
|
|
|
||||
| Step 12 - Graphics Adapters - Optional | ||
|
|
||
|
||
| Maximum # Supported |
|
||
| Tru64 UNIX | OpenVMS |
|
|
|
ATI RADEON 7500 64-MB PCI 2D/3D Graphics Accelerator plus
ATI RADEON NEBS kit
NOTE: Slot 0 must be used for this configuration. |
1 | 1 |
3X-PBXGG-TA
|
|
|
||||
| Step 13 - Software - Required selection of media and documentation for first system on site | ||
|
|
||
| Tru64 UNIX |
|
|
|
|
||
| When using Tru64 UNIX V5.0A or later | Tru64 UNIX media and online documentation on CD-ROM |
QA-6ADAA-H8
|
| Tru64 UNIX full hard copy documentation |
QA-6ADAA-GZ
|
|
| TruCluster Plus Software Package with licenses for TruCluster Server, Logical Storage Manager, and AdvFS Utilities |
QP-6R9AC-AA
|
|
| TruCluster Server License |
QL-6BRAC-AA
|
|
| AdvFS Utilities License |
QL-0EGAE-AA
|
|
| Logical Storage Manager License |
QL-2GVAE-AA
|
|
| Advanced Server for Tru64 UNIX, 25 client concurrent use license |
QL-5U29M-3D
|
|
| Advanced Server for Tru64 UNIX, 50 client concurrent use license |
QL-5U29M-3E
|
|
| Advanced Server for Tru64 UNIX, 100 client concurrent use license |
QL-5U29M-3F
|
|
| Advanced Server for Tru64 UNIX, 250 client concurrent use license |
QL-5U29M-3G
|
|
| Advanced Server for Tru64 UNIX, 500 client concurrent use license |
QL-5U29M-3H
|
|
| Layered products media and documentation for Tru64 UNIX on CD-ROM |
QA-054AA-H8
|
|
| DECnet/OSI end-system license for Tru64 UNIX |
QL-MTJAE-AA
|
|
| DECnet/OSI extended function license for Tru64 UNIX |
QL-MTKAE-AA
|
|
|
|
||
| OpenVMS |
|
|
| OpenVMS V7.3-1 media and online
documentation on CD-ROM |
QA-MT1AR-H8 | |
| OpenVMS V7.3-1 media and online
documentation on CD-ROM |
QA-MT1AT-H8 | |
| OpenVMS media and online documentation
on CD-ROM |
QA-MT1AA-H8 | |
| OpenVMS hard copy documentation |
QA-001AA-GZ | |
| Layered products media and documentation
for OpenVMS on CD-ROM |
QA-03XAA-H8 | |
| Open3D for OpenVMS on CD-ROM, includes graphics drivers | QA-0ADAA-H8 | |
|
||
| Concurrent Use 1-user license |
QL-MT3AA-3B
|
|
| Concurrent Use 2-user license |
QL-MT3AA-3C
|
|
| Concurrent Use 4-user license |
QL-MT3AA-3D
|
|
| Concurrent Use 8-user license |
QL-MT3AA-3E
|
|
| Concurrent Use 16-user license |
QL-MT3AA-3F
|
|
| Concurrent Use 32-user license |
QL-MT3AA-3G
|
|
| Concurrent Use 64-user license |
QL-MT3AA-3H
|
|
| Concurrent Use 128-user license |
QL-MT3AA-3J
|
|
| Concurrent Use 256-user license |
QL-MT3AA-3K
|
|
| Traditional Unlimited User license |
QL-MT2AE-AA
|
|
| OpenVMS Cluster license for Alpha systems |
QL-MUZAC-AA
|
|
| OpenVMS Cluster Client license for Alpha systems |
QL-3MRAC-AA
|
|
| OpenVMS Cluster Client-to-Full OpenVMS Cluster Migration license |
QL-6J7AC-AA
|
|
|
|
||
|
Step 14 - Hardware and Software Support Services |
||
|
|
||
| Hardware and Software Support Services |
|
|
|
|
||
| HP Care Pack Services |
|
|
|
|
||
| Program Features Principal Server/Station | ||
| HP Support Plus |
|
|
|
|
||
| HP Support Plus 24 |
|
|
| HP Proactive 24 |
|
|
| HP Critical Service |
|
|
|
|
||
| Program Features - Additional Services | ||
| SSPs (Subsequent System Packages) |
|
|
|
|
||
| Installation |
|
|
|
|
||
| Installation & Startup HP O/S |
|
|
|
|
||
| HP Care Pack Services for AlphaServer TS15 Systems (sold via legacy Order Management System) | ||||
| Model/HP Care Pack Services | Principal Server/ 1 year |
Principal Server/ 3 years |
Subsequent Systems 1 year |
Subsequent Systems 3 years
|
|
AlphaServer TS15
|
|
|
|
|
|
HP Support Plus
|
FP-A01CA-12 |
FP-A01CA-36 |
FP-A21CA-12 |
FP-A21CA-36 |
|
HP Support Plus 24
|
FP-A02CA -12 |
FP-A02CA-36 |
FP-A22CA-12 |
FP-A22CA-36 |
|
Installation
|
FP-AINST-CA |
FP-AINST-CA |
FP-AINST-CA |
FP-AINST-CA |
|
Installation & Startup
|
FP-ASTAR-CA | FP-ASTAR-CA | FP-ASTAR-CA | FP-ASTAR-CA |
| HP Care Pack Services for AlphaServer TS15 Systems (sold via Fusion Order Management System) | ||||
| 1-year Package ID# | Option ID# | 3-year Package ID# | Option ID# | |
|
HP Support Plus
|
HA109A1 |
6HP |
HA109A3 |
6HP |
|
HP Support Plus 24
|
HA110A1 |
6HP |
HA110A3 |
6HP |
|
HP Proactive 24
|
HA111A1 |
6HP |
HA111A3 |
6HP |
|
HP Critical Service
|
HA112A1 | 6HP | HA112A3 | 6HP |
|
NOTES:
|
||
|
|
Technical Specifications
|
Physical Characteristics |
Dimensions (H x W x D) | 5.1 x 17.6 x 19 in (13 x 45 x 48 cm) |
| Weight (maximum) | 41 lb (16.3 kg) | |
|
|
||
|
System |
||||
| Environmental | Temperature | Operating (Rackmount) | 41° to 104° F (5° to 40° C) | |
| Short Term | -23° to 122° F (5° to 50° C) | |||
| NOTE: Maximum operating temperature at sea level. Reduce by 1.8° F (1° C) for each 2,000 ft (660 m) above sea level. | ||||
| Non-operating | -40° to 151° F (-40° to 66° C) | |||
| Humidity | Operating | 5% to 85% | ||
| Non-operating | 5% to 90% | |||
| Heat Dissipation | Single unit = 220 Watts = 752 BTU/Hr | |||
| Rack of 10 systems = 2200 Watts = 7513 BTU/Hr | ||||
| Equipment dimensions measured in normal mounting configuration | Height |
5.25 inches (13.36 cm) | ||
| Width |
17.5 inches (44.45 cm) | |||
| Depth | 17.24 inches (43.79 cm) | |||
| Equipment footprint | 8.5 square ft (0.79 square meters) | |||
| Equipment total weight | 41 lbs (18.6 kg) | |||
| Equipment floor loading (GR 63: O2 18, R2 19) | 4.82 lbs/square ft | |||
| Equipment heat release | 370 Watts | |||
| Equipment heat release (GR 63: R4 11, O4 12) | Frame: | 43.5W/square ft | ||
| Shelf: | 99.4 W/square ft/ft | |||