Overview
| HP bc1000 blade PC
| ||
| HP
bc1000 blade PC |
| At a Glance |
|
| Configuration Steps |
| For a complete configuration of the HP bc1000 blade PC system, you need: |
| 1. HP bc1000 blade PC (sold in a single-pack or 10-pack) |
![]() |
| 2. HP e-Class Blade PC Enclosure (each can hold up to 20 blade PCs). The enclosure comes bundled with 20 licenses for the ProLiant Essentials Rapid Deployment Pack. |
![]() |
| 3. C-GbE Interconnect Switch (with 4 10/100/1000T Gigabit Ethernet RJ45 uplinks for up to 40-to-1 network cable reduction). |
![]() |
|
|
Standard Features
| HP bc1000 blade PC | |
| Processor | One Transmeta Efficeon TM8600 1.0-GHz processor, integrated North Bridge with 400-MHz Hyper Transport South Bridge interface |
|
| |
| Cache Memory | 1024K L2 |
| | |
| Chipset | ALi
M1563M South Bridge NOTE: For more information regarding Acer Labs Inc, please see the following URL: http://www.ali.com.tw/. |
| | |
| Memory | Standard | 512-MB
DDR SDRAM PC2700 (333-MHz) (1x512 MB SODIMM) (NOTE: 32 MB of system RAM is reserved for processor usage.) |
| Maximum | 1024 MB (2 SODIMM slots total) | |
| | ||
| Network Controller | Two 5705F 10/100 Integrated Network Controllers. NIC 1is compliant with PXE |
| | |
| Internal Storage | One 40-GB Ultra ATA/100 5400 rpm hard drive |
| | |
| Industry Standard Compliance | ACPI 1.0b;
ANSI C63.4 - 1992; C.I.S.P.R. Pub 22; CFR 47, Part 15; EN 55022; EN 55024; EN 60950: 2000; ICES-003; IEC 61000-4, Section 2-6, 8, 11; IEC 730-1; IEC 801, Part 2; IPC-A-610; PC2700; PCI 2.3; PXE 2.1; SPD 1.2B; UL 94; UL 796; USB 1.1 |
| | |
| Manageability | HP
Systems Insight Manager ROM Based Setup Utility (RBSU) Automatic System Recovery (ASR) System Software Manager (SSM) DOS-based replicated setup utility (REPSET) Unit ID LED |
|
| |
| High Availability | Robust boot block
recovery ROM F5 auto roll over to new blade Dual network communication paths |
| | |
| Security | Administrator's password |
| | |
| OS Support | Microsoft® Windows® XP Professional with Service Pack 2 |
| | |
| HP e-Class Blade PC Enclosure (sold separately) | |
| Rack Capability | Mounts in HP 10000 and 9000 series, HP System-E, as well as third-party, and Telco racks. Rack mounting hardware for HP and third-party racks ships standard with each blade enclosure. Telco rack-mounting hardware is a separately available option kit. |
| | |
| Rack Airflow Requirements | The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted blade PCs. The HP 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with blade PCs using the latest processors. |
| CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: | |
| |
| CAUTION:
Always use blanking panels to fill all remaining empty front panel U-spaces in
the rack. This arrangement ensures proper airflow. Using a rack without blanking
panels results in improper cooling that can lead to thermal damage. NOTE: Please consult the Setup & Installation Guide for the blade PC for additional details. | |
| | |
| Enclosure includes | 3U high rack-mountable
chassis with 20 blade PC bays Rack mounting hardware for HP, Compaq-branded and third-party racks Rear bay for Interconnect Switch for network cable management Two (2) Diagnostic Adapters (see features following) for connecting keyboard, video, mouse and other devices locally to individual blade PCs ProLiant Essentials Foundation Pack licenses for 20 Blade PCs (see features following), includes the HP Systems Insight Manager and ProLiant Essentials Rapid Deployment Pack CD Four hot-plug fans Dual hot-plug power supplies (600 watts each), power cords Blade PC blanks (to fill 19 of the 20 blade PC bays) Null-modem cable for serial connection to the Integrated Administrator serial "Console" connector HP Documentation CD |
| | |
| Diagnostic Adapter Interfaces | NOTE: Two Diagnostic Adapters are included with every enclosure. |
| Blade
PC LEDs (6) PS/2 Mouse PS/2 Keyboard VGA monitor (functional only when graphics diagnostics card installed) Serial RS-232 port USB 1.1 ports (2) | |
| | |
| ProLiant Essentials Foundation Pack Software | HP Systems Insight Manager | Systems
Insight Manager helps maximize system uptime and performance and reduces the cost
of maintaining the IT infrastructure by providing proactive notification of problems
before those problems result in costly downtime and reduced productivity. Insight
Manager is easy to set up and provides rapid access to inventory information. http://www.hp.com/go/hpsim/. |
| ProLiant Essentials Rapid Deployment Pack | An automated
solution for deployment and provisioning, enabling companies to quickly and easily
adapt to changing business demands. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. | |
| Interconnect Switch Management System and Utilities | Full featured web-based interface, menu-driven console interface, SNMP-based scripting utility and example scripts, SNMP and RMON MIBs, and TFTP utilities for management of interconnect switch. | |
| | ||
| C-GbE Interconnect Switch Features (sold separately) |
For
more information on the C-GbE Interconnect Switch, please visit the Web site at: |
| |
| HP Integrated Administrator Features |
|
| CAUTION:
The enclosure link (RJ-45) connectors on the interconnect tray are not to be used.
Connecting an external device to these enclosure link (RJ-45) connecters may damage
your external device. For more information on the Integrated Administrator, please visit the Web site at: http://h18000.www1.hp.com/products/servers/proliant-bl/e-class/integrated-admin.html. |
| |
| Service and Support | HP Services provides
a wide range of service offerings, including a three-year, limited parts warranty
on the HP bc1000 blade PC. CAUTION: Do not ship the blade PCs and enclosure while inside the rack without first installing the e-Class Enclosure Shipping Bracket (part number PH555A). Failure to use the shipping bracket may cause damage to the blade PC and/or enclosure, thereby voiding the warranty. The HP e-Class Blade PC Enclosure has a three-year, limited warranty on parts, labor and on-site support. Warranties are fully supported by a network of resellers and service
providers in over 160 countries. HP warranty assistance is available 7x24, toll
free in the United States and Canada. Other additional support services may be
covered under warranty or available for an additional fee.
NOTE:
For more information, customer/resellers can contact http://www.hp.com/services/carepack. |
|
|
Models
| bc1000
blade PC DS658A (1 pack) | Processor | 1.0-GHz Transmeta Efficeon TM8600 |
| Cache Memory | 1024K L2 | |
| Memory | 512-MB DDR SDRAM PC2700 (333-MHz) | |
| Network Controller | Two Broadcom 5705F 10/100 Integrated NICs | |
| Hard Drive | 40-GB Ultra ATA/100 5400 rpm | |
| Form Factor | Plugs vertically into HP e-Class Blade PC Enclosure | |
|
| ||
| bc1000
blade PC DS659A (10 pack) | Processor | 1.0-GHz Transmeta Efficeon TM8600 |
| Cache Memory | 1024K L2 | |
| Memory | 512-MB DDR SDRAM PC2700 (333-MHz) | |
| Network Controller | Two Broadcom 5705F 10/100 Integrated NICs | |
| Hard Drive | 40-GB Ultra ATA/100 5400 rpm | |
| Form Factor | Plugs vertically into HP e-Class Blade PC Enclosure |
|
|
Options
| Enclosure and Switch | HP e-Class Blade PC Enclosure (includes 20 licenses for ProLiant Essentials Rapid Deployment Pack at 50% of the standard per-node license list price) |
DW366A |
| Enclosure
Shipping Bracket Kit NOTE: When shipping an enclosure in a rack, shipping brackets must be installed to the rack. |
||
| C-GbE Interconnect Switch (includes Integrated Administrator module) |
DW367A | |
| | ||
| Memory | 512-MB DDR SDRAM PC2700 (333-MHz) Option Kit (1 x 512 MB) |
PA715A |
| | ||
| Miscellaneous | PS/2 Mouse | DD440B |
| PS/2 Keyboard | DT527A | |
| TFT5600 Rackmount Keyboard and Monitor | 221546-xx1 | |
| TFT721OR 17-inch Rackmount Monitor | 348373-B21 | |
| Integrated Keyboard and Drawer | 257054-xxx | |
| External USB MultiBay Caddy | DC373A#ABA | |
| Third-party Rail Kit for HP Input Devices | 287139-B21 | |
| Telco Rail Kit for HP Input Devices | 287138-B21 | |
| MultiBay 24X CD-ROM | 217396-930 | |
| Graphics Diagnostics Card (5 pack) | DV300C | |
| | ||
| UPS and PDU Power Cord Matrix | Please
see the UPS and PDU cable matrix that lists cable descriptions, requirements,
and specifications for UPS and PDU units: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf. |
| | |
| Uninterruptible Power Systems Rack | HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage (NA) | 204404-001 |
| HP UPS R1500 XR (1500VA, 1340 Watt), High Voltage (Int'l) | 204404-B31 | |
| HP UPS R1500 XR (1500VA, 1340 Watt), Low Voltage (Japan) | 204404-291 | |
| HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage (NA) | 192186-001 | |
| HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (NA) | 192186-002 | |
| HP UPS R3000 XR (2400VA, 2250 Watt), Low Voltage (Japan) | 192186-291 | |
| HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Japan) | 192186-292 | |
| HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Int'l detachable cord) | 192186-B31 | |
| HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A IEC309 Plug) | 192186-B32 | |
| HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A CEE 7/7 SCHUKO Plug) | 192186-B33 | |
| HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A BS-546 Plug) | 192186-AR1 | |
| HP UPS R5500 XR (5000VA, 4500 Watt), High Voltage (NA and Japan) | 326529-D71 | |
| HP UPS R5500 XR (6000VA, 5400 Watt), High Voltage (Int'l) | 326529-B31 | |
| Rack-Mountable UPS R6000 (6000VA,
6000 Watt) High Voltage (NA) NOTE: The UPS R6000 has a hardwired input. |
347207-001 | |
| Rack-Mountable
UPS R6000 (6000VA, 6000 Watt) High Voltage (Int'l) NOTE: The UPS R6000 has a hardwired input. |
347207-B31 | |
| Rack-Mountable
UPS R6000 (6000VA, 6000 Watt) High Voltage (Japan) NOTE: The UPS R6000 has a hardwired input. |
347207-291 | |
| UPS R12000 XR N+ x (200-240V)
(WW-hardwired) NOTE: The UPS R12000 XR has a hardwired input and output. |
207552-B22 | |
|
| ||
| UPS Options | SNMP Serial Port Card NOTE: Supports tower and rack UPS XR models ranging from 1000 3000VA. | 192189-B21 |
| Six Port Card NOTE: Supports tower and rack UPS XR models ranging from 1000 3000VA. | 192185-B21 | |
| High to Low Voltage Transformer
(250VA) NOTE: Supports R6000 UPS series only. 2.5 amps @ 125 Volts max output across two NEMA 5-15. | 388643-B21 | |
| Extended Runtime Module, R1500
XR NOTE: 2U each, two ERM maximum. | 218971-B21 | |
| Extended Runtime Module, R3000
XR NOTE: 2U each, one ERM maximum. | 192188-B21 | |
| Extended Runtime Module, R5500
XR NOTE: 3U each, two ERM maximum. | 326564-B21 | |
| Extended Runtime Module, R6000 NOTE: 3U each, two ERM maximum. | 347224-B21 | |
| Extended Runtime Module, R12000
XR, 4U NOTE: 4U each, two ERM maximum. | 217800-B21 | |
| R12000 XR BackPlate Receptacle
Kit, (2) L6-30R (NA) NOTE: The R12000 XR BackPlate Kit has a hardwired input. | 325361-001 | |
| R12000 XR BackPlate Receptacle
Kit, (2) IEC-309R (WW) NOTE: The R12000 XR BackPlate Kit has a hardwired input. | 325361-B21 | |
| SNMP-EN Adapter NOTE: Supports R6000 UPS series only. | 347225-B21 | |
| Multi-Server
UPS Card NOTE: Supports R6000 UPS series only. | 123508-B21 | |
| Scalable UPS Card NOTE: Supports R6000 UPS series only. | 123509-B21 | |
| | ||
|
Rack-Mountable PDUs 1U/0U (Up to 12 outlets) NOTE: 0U mounting brackets shipped with the unit (separate option kit for 1U mounting). |
HP Power Distribution Unit-16A (200 to 240V) (WW) |
207590-B21 |
| HP Power Distribution Unit-32A (200 to 240V) (Int'l) |
207590-B31 | |
| HP Power Distribution Unit-40A (200 to 240V) (WW) |
207590-B23 | |
| NOTE:
Please see the following Power Distribution Unit (Zero-U/1U PDU) QuickSpecs for
additional options, including cables: http://h18000.www1.hp.com/products/quickspecs/10838_na/10838_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/10838_div/10838_div.html (Worldwide) | ||
| | ||
| Modular
PDUs 1U/0U (Up to 32 outlets) | Modular
Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC) (WW) NOTE: This model has a detachable input power cord and is adaptable to country specific requirements. The 16A PDU also connects to the high volt models of the UPS R3000 XR and R6000 models. Cable P/N 340653-001 required if connecting to UPS R3000 XR (192186-002 NA-High Volt model only). | 252663-B24 |
| Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC) (NA, Japan) | 252663-D72 | |
| Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC) (NA, Japan) | 252663-D71 | |
| Modular Power Distribution Units (mPDU), High Volt Model, 32A (200-240 VAC) (Int'l) | 252663-B31 | |
| Modular Power Distribution Units
(mPDU), High Volt Model, 40A (200-240 VAC) (WW) NOTE: This mPDU (252663-B21), 40A model has a hardwired input. | 252663-B21 | |
| NOTE: Please
see the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables and country specific power
cords: http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.html (Worldwide) | ||
| | ||
| PDU Options | Third Party PDU Mounting
Kit NOTE: This kit allows you to mount the Modular PDUs in racks other than the 9000/10000 Series racks (any racks using the standard 19" rail). For more details please refer the Modular PDU QuickSpecs. |
310777-B21 |
|
| ||
| Enterprise Configurator | Please see the CO for configuration assistance at: http://www.hp.com/products/configurator. |
| | |
| HP Rack 10000 Series (Graphite Metallic) | S10614 (14U) Rack Cabinet Shock Pallet | 292302-B22 |
| HP Rack 10647 (47U) Pallet | 245160-B21 | |
| HP Rack 10647 (47U) Crated | 245160-B23 | |
| HP Rack 10642 (42U) Pallet | 245161-B21 | |
| HP Rack 10642 (42U) Shock Pallet | 245161-B22 | |
| HP Rack 10642 (42U) Crated | 245161-B23 | |
| HP Rack 10636 (36U) Pallet | 245162-B21 | |
| HP Rack 10636 (36U) Shock Pallet | 245162-B22 | |
| HP Rack 10636 (36U) Crated | 245162-B23 | |
| HP Rack 10622 (22U) Pallet | 245163-B21 | |
| HP Rack 10622 (22U) Shock Pallet | 245163-B22 | |
| HP Rack 10622 (22U) Crated | 245163-B23 | |
| HP Rack 10842 (42U) 800 mm wide Pallet | 257415-B21 | |
| HP Rack 10842 (42U) Crated | 257415-B22 | |
| NOTE:
-B21 (pallet) used to ship empty racks shipped on a truck -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels) -B23 (crated) used for air shipments of empty racks NOTE: Not all HP equipment is qualified to be shipped in the Rack 10000 series. | ||
| NOTE: Please
see the Rack 10000 QuickSpecs for Technical Specifications such as height, width,
depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.html (Worldwide) For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/racks/index.html. | ||
| | ||
| Rack Options for HP Rack 10000 Series | Rack
Blanking Panels Graphite (Multi) NOTE: Contains one each of 1U, 2U, 4U and 8U. | 253214-B26 |
| Rack Blanking Panels Graphite
(1U) NOTE: The Rack Blanking Panels Kit contains 10 each of (1U). | 253214-B21 | |
| Rack Blanking Panels Graphite
(2U) NOTE: The Rack Blanking Panels Kit contains 10 each of (2U). | 253214-B22 | |
| Rack Blanking Panels Graphite
(3U) NOTE: The Rack Blanking Panels Kit contains 10 each of (3U). | 253214-B23 | |
| Rack Blanking Panels Graphite
(4U) NOTE: The Rack Blanking Panels Kit contains 10 each of (4U). | 253214-B24 | |
| Rack Blanking Panels Graphite
(5U) NOTE: The Rack Blanking Panels Kit contains 10 each of (5U). | 253214-B25 | |
| 600mm Stabilizer Kit Graphite | 246107-B21 | |
| Baying Kit for Rack 10000 series (Carbon) | 248929-B21 | |
| 42U Side Panel Graphite Metallic | 246099-B21 | |
| 110V Fan Kit (Graphite) NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 5-15P. | 257413-B21 | |
| 220V Fan Kit (Graphite) NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 6-15P. | 257414-B21 | |
| 36U Side Panel Graphite Metallic | 246102-B21 | |
| 47U Side Panel Graphite Metallic | 255486-B21 | |
| 9000/10000 Series Offset Baying
Kit (42U) NOTE: This kit can be used to connect 9000 and 10000 series racks of the same U height together. Kit contents include hardware for connecting racks and a panel to cover the 100mm gap at the rear of the two racks. | 248931-B21 | |
| | ||
| Cable Management | FC Cable Routing Spool box of 12 | 293357-B21 |
| Rail-to-Rail FC Cable Routing | 293358-B21 | |
| Side Rail FC Routing box of 6 | 293359-B21 | |
| Compaq Networking Cable Management Kit | 292407-B21 | |
| Cable Management D-Rings Kit |
168233-B21 | |
|
| ||
| Rack Options for Rack 10000 Series | Monitor Utility Shelf | 303606-B21 |
| Ballast Option Kit | 120672-B21 | |
| 100kg Sliding Shelf | 234672-B21 | |
| Rack Rail Adapter Kit (25" depth) | 120675-B21 | |
| 9000/10000 Grounding Kit | 260457-B21 | |
| 100-kg Shelf Kit NOTE: This 100Kg Shelf Kit (PN 234672-B21) supports the Rack 10000 and 9000 series only. | 234672-B21 | |
| | ||
| Rack Options for HP, Third Party and Telco racks | Telco rack-mounting hardware kit for HP e-Class Blade PC Enclosure | 266076-B21 |
| Enclosure
Shipping Bracket Kit NOTE: When shipping an enclosure in a rack shipping brackets must be installed to the rack. | 293119-B21 | |
| NOTE: For more information on rack and rack options, please visit the following url: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. |
|
|
Memory
| HP bc1000 blade PC |
| Standard
Memory 512-MB 333-MHz DDR SDRAM (1x512 MB SODIMM) installed. (NOTE: 32 MB of system RAM is reserved for processor usage.) Standard Memory Plus Optional Memory Up to 1024 MB of DDR SDRAM is available with the installation of optional DDR SDRAM memory expansion kits (sold separately). |
| Memory | Slot | ||
| 1 | 2 | ||
| Standard | 512 MB | Empty | 512 MB |
| Maximum | 1024 MB | 512 MB | 512 MB |
|
|
Technical Specifications
| HP bc1000 blade PC | Dimensions | Height | 4.7 in (11.94 cm) |
| Width | 0.8 in (2.03 cm) | ||
| Depth | 15.5 in (39.37 cm) | ||
| Weight | Maximum | 2.2 lb (1.0 kg) | |
| Temperature1 | Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating shipping | -40° to 140° F (-40° to 60° C) | ||
| Non-operating storage | -4° to 140° F (-20° to 60° C) | ||
| Relative humidity1 (noncondensing) | Operating | 10% to 90% | |
| Non-operating shipping | 10% to 90% | ||
| Non-operating storage | 10% to 95% | ||
| LEDs (Top to bottom) | Unit identification | Off = off | |
| Steady blue = blade identified | |||
| Blinking blue = being accessed remotely | |||
| Health | Off = off | ||
| Green = health good | |||
| Amber = degraded or power up prohibited by the Integrated Administrator | |||
| Blinking or steady red = critical | |||
| NIC 1 | Off = off | ||
| Green = linked to network | |||
| Blinking green = Activity on network | |||
| NIC 2 | Off = off | ||
| Green = linked to network | |||
| Blinking green = activity on network | |||
| Drive activity | Off = No drive activity | ||
| Blinking green = drive activity | |||
| Power | Off = no AC power to blade or enclosure | ||
| Amber = Enclosure on and in good health | |||
| Green = blade power on | |||
| NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa. | |||
|
| |||
| 40-GB Ultra ATA/100 Hard Drive | Capacity | 40 GB | |
| Interface | Ultra ATA 100 | ||
| Transfer
rate synchronous (maximum) | 100 MB/s | ||
| Seek time (typical reads, including settling) | Single track | 1.5 ms | |
| Average | 12 ms | ||
| Maximum | 22 ms | ||
| Rotational speed | 5400 rpm | ||
|
| |||
| Broadcom 5705F 10/100 Integrated NIC | Network interface | 10Base-T/100Base-TX | |
| Compatibility | IEEE 802.3/802.3u compliant | ||
| Data transfer method | 32-bit bus-master PCI | ||
| Features | NIC 1 WOL enabled and PXE compliant | ||
| Network transfer rate | 10Base-T (half-duplex) | 10 Mb/s | |
| 10Base-T (full-duplex) | 20 Mb/s | ||
| 100Base-TX (half-duplex) | 100 Mb/s | ||
| 100Base-TX (full-duplex) | 200 Mb/s | ||
| Connector | Mates into enclosure center wall assembly | ||
| Cable support | 10Base-T | Categories 3, 5, or 6 UTP; up to 328 ft (100 m) | |
| 100Base-TX | Category 5 or 6 UTP; up to 328 ft (100 m) | ||
|
| |||
| Enclosure | Dimensions | Height (3U) | 5.25 in (13.34 cm) |
| Width | 19 in (48.26 cm) | ||
| Depth | 27 in (68.58 cm) | ||
| Weight (with interconnect tray) | No blade PCs | 59 lb (26.76 kg) | |
| 20 blade PCs | 103 lb (46.7 kg) | ||
| Rated input (autosensing) | Voltage | Minimum:
90 VAC Maximum: 264 VAC Nominal: 100 to 120 VAC or 200 to 240 VAC | |
| Frequency | 47 to 63 Hz | ||
| Current | 11.7
A at 90 VAC 8.5 A at 120 VAC 4.3 A at 240 VAC | ||
| Power | 1000 W | ||
| BTUs | Per hour | 3416 | |
| Temperature1 | Operating | 50° to 95° F (10° to 35° C) | |
| Shipping, 72 hours | -40° to 140° F (-40° to 60° C) | ||
| Relative humidity (noncondensing) | Operating | 10% to 90% | |
| Non-operating | 10% to 95% | ||
| Management | Enclosure
self recovery Health logs Redundant power supply utility Automatic System Recovery (ASR) | ||
| High availability | Redundant
hot-plug power supplies Redundant hot-plug fans | ||
| NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa. | |||
|
| |||
| Enclosure Hot-Plug Power Supply | Dimensions | Height | 3.579 in (9.14 cm) |
| Depth | 10.24 in (28.45 cm) | ||
| Width | 4.47 in (11.43 cm) | ||
| Weight | 6.5 lb (2.95 kg) | ||
| Rated input | Voltage (autosensing) | 100 to 127 VAC (200 to 240 VAC) | |
| Frequency | 47 to 63 Hz | ||
| Current | 8.5 A at 120 VAC (4.3 A at 240 VAC) | ||
| Power | 1000 W | ||
| Maximum peak power | 1167 W | ||
| Rated output | Voltage/current | 5.01 V - 0.5 A ~ 34 A | |
| 3.33 V - 0.5 A ~ 36 A | |||
| 12.1 V - 0.5 A ~ 38 A | |||
| 5 Vaux - 0.2 A ~ 8 A | |||
| Power RMS | 600 W | ||
| Maximum peak power | 700 W for 2 minutes | ||
| Temperature1 | Operating | 50° to 55° F (10° to 35° C) | |
| Non-operating, shipping | -40° to 85° F (-40° to 60° C) | ||
| Relative humidity1 (noncondensing) | Operating | 10% to 90% | |
| Non-operating | 10% to 95% | ||
| Dieletric voltage withstand | Input to output | 2000 VAC minimum | |
| Input to ground | 1500 VAC minimum | ||
| NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa. | |||
|
| |||
| C-GbE Interconnect Switch | General | Two 24-port Managed Layer 2 Ethernet switches for network cable reduction; fully pre-configured for immediate operation | |
| Performance | 4.0 Gbps Switching bandwidth | ||
| 12 million pps aggregate throughput (64-byte packets) | |||
| Full-wire speed for all connections | |||
| Forwarding mode | Store and forward | ||
| MAC addresses | 16,382; MAC address based filtering and MAC address packet priority configuring | ||
| Memory | 64 MB Main | ||
| 12 MB Flash | |||
| 32 MB Packet Buffer | |||
| Ports | Four RJ-45 10/100/1000 T/TX/T Gigabit Ethernet uplink ports for customer use | ||
| Forty 10/100 T/TX fast Ethernet downlink ports dedicated to blade PC to interconnect switch network connections | |||
| Two 10/100 T/TX Fast Ethernet ports dedicated to inter-switch module communications | |||
| One RS-232 DB-9 port (console connector for Integrated Administrator) | |||
| One 10/100 T/TX Fast Ethernet port (Network management connector for Integrated Administrator) | |||
| Auto-negotiation and auto-sensing with full-duplex | |||
| Management | Web-based interface with graphical user interface | ||
| Console menu driven Interface via local RS-232 and Telnet | |||
| Scriptable command line interface (CLI) | |||
| SNMP v1 (RFC 1157) with scripting tool and example scripts | |||
| RMON v1 (RFC 1757) groups 1, 2, 3, and 9 | |||
| Telnet (RFC 854) | |||
| MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface MIB (RFC 2233), 801.1Q MIB (RFC 2684), RMON1 MIB (RFC 1757) groups 1, 2, 3, and 9, Ethernet MIB (RFC1643) and HP-specific switch MIBs | |||
| XML human read/write configuration file | |||
| TFTP client (RFC 783) for backup and remote download of configuration and history log files | |||
| IGMP (Internet Group Management Protocol) multicasting | |||
| Uplink port speed and link activity LEDs | |||
| Simple network time protocol (SNTP) | |||
| Broadcast, multicast, and DA-unknown packet storm control | |||
| BootP and DHCP client support | |||
| Port mirroring | |||
| HP Interconnect Switch Management System and Utilities | |||
| High availability | Dual network communication paths using redundant, non-blocking layer 2 switch modules with redundant inter-module communication links | ||
| Two redundant uplink ports per each interconnect switch module | |||
| Spanning tree protocol for loop-free path redundancy | |||
| Security | Multilevel user names and passwords with configurable time out period setting, IP address restriction | ||
| IEEE standards compliance | IEEE 802.3 10Base-T Ethernet | ||
| IEEE 802.3u 100Base-TX Ethernet | |||
| IEEE 802.3ab 1000Base-T Ethernet | |||
| IEEE 802.1D Spanning Tree Protocol | |||
| IEEE 802.1p Quality of Service (QoS) Packet Prioritization | |||
| IEEE 802.3x Flow Control | |||
| Form factor | Removable interconnect tray that plugs into the rear of the server blade enclosure | ||
| Network transfer rate | 10Base-T (half-duplex) | 10 Mb/s | |
| 10Base-T (full-duplex) | 20 Mb/s | ||
| 100Base-TX (half-duplex) | 100 Mb/s | ||
| 100Base-TX (full-duplex) | 200 Mb/s | ||
| 1000Base-T (full-duplex, uplink ports only) | 2000 Mb/s | ||
| Cable support | 10Base-T | Categories 3, 5, or 6 UTP; up to 328 ft (100 m) | |
| 100Base-TX | Category 5 or 6 UTP; up to 328 ft (100 m) | ||
| 1000Base-T (uplink ports only) | Category 5 or 6 UTP; up to 328 ft (100 m) | ||
|
| |||
| © Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |