Overview
| HP ProLiant DL360 Generation 4 (G4)
| ||||||||||||||||||
At
A Glance
|
|
|
Standard Features
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | |
| Processor One of the following depending on Model |
Intel Xeon Processor 3.0 GHz/800MHz -1MB L2 |
| Intel Xeon Processor 3.4 GHz/800MHz -1MB L2 | |
| Intel Xeon Processor 3.6 GHz/800MHz -1MB L2 | |
|
|
|
| Cache Memory | 1MB Level 2 cache |
|
|
|
| Upgradeability | Upgradeable to dual processing |
| | |
| Chipset | Intel chipset is E7520 |
| | |
| Memory Protection | Online spare |
| Advanced ECC | |
|
|
|
| Memory | Type | PC2700 DDR 333 SDRAM |
| Standard | 1 GB (1 x 1024 MB) | |
| Maximum | 8 GB | |
|
|
||
| Network Controller | Embedded NC7782 Dual Port NIC |
|
|
|
| Expansion Slots | Slot Number | Bus Speed | Bus Number* | Device Number** | Hot Plug | PCI Voltage | Notes |
| 1 | 64bit/133MHz PCI-X | 7 |
0 |
no |
3.3 Volt | ||
| 1 | PCI Express x8(optional) | 3 |
0 |
no |
n/a | ||
| 2 | 64bit/133MHz PCI-X | 10 |
0 |
no |
3.3 Volt | ||
| 2 | PCI Express x8(optional) | 13 |
0 |
no |
n/a | ||
| *NOTE:
Default bus assignment. Inserting cards with PCI bridges may alter the actual
bus assignment number. **NOTE: Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest Device ID by bus (starting with the lowest bus). NOTE: For more information regarding PCI-X, please see the following URL: http://www.hp.com/servers/pci-x. NOTE: All slots can accept universal keyed PCI cards. |
| ||||||
| Manageability |
Integrated Lights-Out (iLO) Management (integrated on motherboard) |
|
|
|
| Storage Controllers | SCSI Models | Smart Array 6i Controller (integrated
on system board of SCSI models) NOTE: The HP ProLiant DL360 G4 does not offer an external SCSI port. |
| SATA Models | HP embedded 2 Port SATA Controller
(integrated on system board of SATA models) NOTE: The HP ProLiant DL360 G4 does not offer an external SCSI port. |
|
|
|
||
| Storage | Diskette Drive | 1.44 MB Diskette Drive; optional in some models |
| Optical Drive | 24x IDE CD-ROM Drive (Low-Profile) (ejectable); optional in some models | |
|
|
||
| Maximum Internal Storage Type | Hot Plug SCSI | 600GB | 2 x 300GB Ultra320 |
| SATA | 1TB | 2 x 500GB Serial ATA | |
| | |||
| Interfaces | Serial | 1 |
| Pointing Device (Mouse) | 1 | |
| Graphics | 1 | |
| Hot Plug Keyboard | 1 | |
| USB | 3 (rear, front, internal) | |
| NOTE:
Please see the following URL for additional information regarding USB support:
http://h18004.www1.hp.com/products/servers/platforms/usb-support.html. | ||
| Network RJ-45 | 2 | |
| iLO remote management port | 1 | |
| | ||
| Graphics | Integrated ATI RAGE XL Video Controller with 8-MB SDRAM Video Memory |
|
|
|
| Form Factor | Rack (1U), (1.75 in/4.45 cm) |
|
|
|
| ProLiant Essentials Foundation Pack Software |
| ||||||||||||||||
| | |||||||||||||||||
| Industry Standard Compliance | ACPI 1.0b Compliant |
| PCI 2.2 Compliant | |
| Microsoft® Logo certifications | |
| USB 1.1 and 2.0 Compliant | |
|
|
|
| Remote Manageability |
Integrated Lights-Out (iLO) Standard Management:
Integrated Lights Out Advanced Pack (optional) |
|
|
|
| Intelligent Manageability |
HP Systems Insight Manager SmartStart Remote Insight Lights-Out Edition ll (optional) ROM-Based Setup Utility (RBSU) Remote-Flash Redundant ROM Integrated Management Log (IML) Server Health logging Automatic Server Recovery-2 (ASR-2) System Interconnect Status Indicators Dynamic sector repairing and drive parameter tracking (with Smart Array controllers) Hot Spare Boot (NOTE: Upon the event of a failed processor or VRM in a multi-processing environment, the system will automatically reboot and use the remaining good processor(s).) Power Down Utility Pre-Failure Warranty (covers processors, as well as SCSI hard drives and memory) |
|
|
|
| Security | Power-on password Keyboard password Diskette drive control Diskette boot control QuickLock, Network Server Mode Removable CD and Floppy Drive Assembly Serial interface control Administrator's password Disk configuration lock Integrated Lights-Out has 12 customizable user accounts and SSL encryption Integrated Lights-Out can be disabled via a Global Setting |
|
|
|
| Server Power Cords | High line cord ships standard with all part numbers, an additional low line cord for US and Japan |
|
|
|
| UPS and PDU Power Cord Matrix |
Please see the UPS and PDU cable
matrix that lists cable descriptions, requirements, and specifications for
UPS and PDU units: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf. |
|
|
|
| Power Supply | SCSI & SATA Models: | 460W Optional (1+ 1 redundant)
power supply NOTE: PN 354587-B21 contains the optional power supply and an IEC power cable only; purchase if connecting to PDU/UPS that supports IEC cables. PN 354587-001 contains a low line (NEMA) power cord only. |
|
|
||
| System Fans | 7 fans ship standard; Fan redundancy standard |
|
|
|
| Required Cabling | For required cabling information, refer to the Web site at http://h18000.www1.hp.com/products/servers/proliantdl360/. |
| | |
| OS Support | Microsoft Windows 2000 Windows Server 2003 Novell NetWare Linux (Red Hat, SuSE, UnitedLinux) Solaris VMware Virtualization Software |
| NOTE: SCSI and
SATA models have different OS support. Please see OS Support Matrix. NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS Support Matrix page at: http://www.hp.com/go/supportos. NOTE: For more complete and up-to-date information on how to buy server operating systems from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html NOTE: For a listing of the latest drivers available for the HP ProLiant DL360, please see: http://h18023.www1.hp.com/support/files/server/us/index.html. NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux Web site at http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html. NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html. |
|
|
|
|
| Rack Airflow Requirements | Rack 10000 series Cabinets The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://h18000.www1.hp.com/products/servers/proliantdl360/index.html. | |
| | |
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and
deployment services for HP servers and storage products. Customers can
choose how their factory solutions are built, tested, integrated, shipped
and deployed. |
|
|
|
| Custom Builder | Please see the Enterprise Configurator for configuration assistance at: http://www.hp.com/products/configurator. |
| | |
| Service and Support |
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of resellers and service providers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. NOTE: Limited warranty includes
3 year parts, 3 year labor, 3-year on-site support. Care Pack services provide a range of life cycle support options that
let you choose the service levels that meet your business requirements,
from basic to mission-critical.
HP Care Pack services include coverage for the HP branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to 3kVA; these items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. |
| NOTE: For more
information on HP Care Pack services, contact any of our worldwide sales
offices or resellers or visit our worldwide Web site on the internet at:
http://www.hp.com/hps/carepack NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at: http://www.hp.com/hps NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html |
|
|
Models
|
DL360R04 X3.4-1MB/800, 2GB SCSI, RPS | Processor | (1) Intel Xeon Processor 3.4 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 1MB level 2 cache | |
| Memory | 2 x 1 GB (Standard) to 8 GB (Maximum) of PC2700 DDR 333 SDRAM | |
| Network Controller | Embedded NC7782 Dual Port NIC | |
| Storage Controller | U320 Smart Array
6i Controller (embedded on system board) NOTE: The HP ProLiant DL360 Generation 4 (G4) does not offer an external SCSI port. | |
| Hard Drives | None
ship standard; system supports up to two hot plug U320 drives NOTE: The HP ProLiant DL360 G4 SCSI models only support U320 Universal Hot Plug drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | Two 460W power supply (1+ 1 redundant) | |
| Optical Drive | 24x IDE CD-ROM Drive (Low-profile) | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
|
DL360R04 X3.4-1MB/800, 1GB SCSI | Processor | (1) Intel Xeon Processor 3.4 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 1MB level 2 cache | |
| Memory | 1 x 1 GB (Standard) to 8 GB (Maximum) of PC2700 DDR 333 SDRAM | |
| Network Controller | Embedded NC7782 Dual Port NIC | |
| Storage Controller | U320 Smart Array
6i Controller (embedded on system board) NOTE: The HP ProLiant DL360 Generation 4 (G4) does not offer an external SCSI port. | |
| Hard Drives | None
ship standard; system supports up to two hot plug U320 drives NOTE: The HP ProLiant DL360 G4 SCSI models only support U320 Universal Hot Plug drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | One 460W power supply (redundant power supply optional) | |
| Optical Drive | 24x IDE CD-ROM Drive (Low-profile) | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
|
DL360R04 X3.4-1MB/800, 1GB 2P SATA |
Processor | (2) Intel Xeon Processor 3.4 GHz/800MHz standard |
| Cache Memory | 1MB level 2 cache | |
| Memory | 1 x 1 GB (Standard) to 8 GB (Maximum) of PC2700 333 DDR SDRAM | |
| Network Controller | Embedded NC7782 Dual Port NIC | |
| Storage Controller | Embedded SATA controller; Non-RAID for controller | |
| Hard Drives | None ship standard; system supports
up to two Serial ATA drives NOTE: When SATA drives are installed, hot-plug capability and LEDs are not currently supported. |
|
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | One 460W power supply (redundant power supply optional) | |
| Optical Drive | Optional on SATA Models | |
| Diskette Drive | Optional on SATA Models | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133 MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
|
|
||
| Country Code Key | Rack Code Key | ||
| XX=00 | US | ||
| XX=20 | Brazil | ||
| XX=29 | Japan | ||
| XX=37 | APD | ||
| XX=42 | EURO | ||
| XX=AA | PRC | ||
|
|
Configuration Information - Factory Integrated Models (North America only)
|
NOTE: For Configure to Order requirements
within EMEA region, please consult local Sales Contact. |
||
| Step 1: Base Configuration (choose one of the following configurable models) | ||
| Models | HP ProLiant DL360G4
SATA Rack CTO Chassis (North America) |
367006-405 |
|
Factory Integrated Model ships with: |
||
|
NC7782 Dual Port PCI-X Gigabit Server Adapter (embedded) |
||
| HP ProLiant DL360G4 SCSI Rack CTO Chassis (North America) |
367007-405
|
|
|
Factory Integrated Model ships with: |
||
|
NC7782 Dual Port PCI-X Gigabit Server Adapter (embedded) |
||
|
|
||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processors | Intel X3.0GHz/800-1MB
DL360G4 FIO BASE |
368152-L21
|
| Intel X3.4GHz/800-1MB
DL360G4 FIO BASE |
354582-L21
|
|
| Intel X3.6GHz/800-1MB DL360G4 FIO BASE | 354583-L21 | |
| Base Memory | 512 MB of Advanced ECC PC2700 DDR SDRAM DIMM Memory Kit (1 x 512 MB) |
358347-B21
|
| 1024 MB of Advanced
ECC PC2700 DDR SDRAM DIMM Memory Kit (1 x 1 GB) |
358348-B21
|
|
| 2048 MB of Advanced ECC PC2700 DDR SDRAM DIMM Memory Kit (1 x 2 GB) |
358349-B21
|
|
| Optical Drive | NOTE:
An Optical Drive is REQUIRED if choosing the 367007-405 SCSI Rack CTO Chassis
Model in Step 1. NOTE: Optical Drives are OPTIONAL if choosing the 367006-405 SATA Rack CTO Chassis Model in Step 1. |
|
| Slimline CD-ROM
Drive 24X NOTE: This CD/ROM Drive (PN 356963-B21) is for SATA models. |
356963-B21
|
|
| Slimline CD-RW/DVD-ROM Combo Option Kit |
331903-B21
|
|
| Slimline DVD-ROM
Drive (8X/24X) Option Kit NOTE: This DVD-ROM Drive (PN 264007-B21) is for SCSI models. It is not supported in SATA models. |
264007-B21
|
|
|
|
||
| Step 3: Choose Additional Factory Integratable Options | ||
| Diskette Drive | 1.44 MB Diskette
drive NOTE: This Diskette Drive is for SATA (367006-405) models |
354588-B21 |
| Optical Drive | NOTE:
The Optical Drive is OPTIONAL for the SATA Rack CTO Chassis Model (367006-405)
but REQUIRED if choosing the SCSI Rack CTO Chassis Model (367007-405) in
Step 1. |
|
| Slimline CD-ROM
Drive 24X NOTE: This CD/ROM Drive (PN 356963-B21) is for SATA models. |
356963-B21
|
|
| Slimline DVD-ROM
Drive (8X/24X) Option Kit NOTE: This DVD-ROM Drive (PN 264007-B21) is for SCSI models. It is not supported in SATA models. |
264007-B21
|
|
| 460W HP redundant power supply with IEC cord only |
354587-B21
|
|
|
|
||
| Step 4: Choose Additional Options for Factory Integration | ||
| NOTE: For additional options, please refer to the "Options" section below. |
|
|
Options
| NOTE: Some options may not be factory integratable. Please contact your local sales representative for additional information. | ||
| HP
ProLiant DL360 G4 Unique Options |
Intel Xeon 3.0 GHz/800MHz-1MB
Processor Option Kit NOTE: This processor option kit (PN 368152-B21) supports the HP ProLiant DL360 G4 only. |
368152-B21 |
| Intel Xeon 3.4 GHz/800MHz-1MB
Processor Option Kit NOTE: This processor option kit (PN 354582-B21) supports the HP ProLiant DL360 G4 only. |
354582-B21 | |
| Intel Xeon 3.6 GHz/800MHz-1MB
Processor Option Kit NOTE: This processor option kit (PN 354583-B21) supports the HP ProLiant DL360 G4 only. |
354583-B21 | |
| 1.44 MB Diskette
Drive NOTE: This Diskette drive is for SATA models only. |
354588-B21 | |
| PCI-e Riser option
(to convert one or both PCI-X to PCI-e slots) |
354589-B21
|
|
| Ambidextrous cable
management arm NOTE: Package contains two cable management arms |
365403-B21
|
|
| Fixed Cord Extension
Bars for 1U servers (2 PDU sticks per kit) |
351655-B21
|
|
| 460W HP redundant power supply with IEC cord only |
354587-B21
|
|
| 460W HP redundant
power supply with US or Japanese NEMA cord only NOTE: The HP ProLiant DL360 G4 ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). For stand-alone deployments or installation without a rack, country-specific power cord options are available. U.S., Japan, & APD models ship with two power cords: IEC-IEC and country-specific NEMA cords. |
354587-001
|
|
|
|
||
| ProLiant
Essentials Value Pack Software | ProLiant Essentials Integrated Lights-Out Advanced Pack | |
| ProLiant
Essentials Integrated Lights-Out Advanced Pack, 1 server Featuring: sophisticated virtual administration features for ultimate control of servers in the data centers and remote sites. |
263825-B21 | |
| NOTE: For additional ProLiant Integrated Light-Out Advanced Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11052_div/11052_div.html | ||
| ProLiant Essentials Intelligent Networking Pack | ||
| ProLiant
Essentials Intelligent Networking Pack - Windows Edition, Single Server License
NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372906-B21 | |
| NOTE: For additional ProLiant Intelligent Networking Pack - Windows License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12062_div/12062_div.html | ||
| ProLiant Essentials Intelligent Networking Pack - Linux Edition, Single Server License |
397004-B21 | |
| NOTE:
For additional ProLiant Intelligent Networking Pack - Linux License Kits please
see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12327_div/12327_div.html | ||
| ProLiant Essentials Performance Management Pack | ||
| ProLiant
Essentials Performance Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key, HP Management CD and documentation. NOTE: The most recent version of the software can always be downloaded at http://www.hp.com/products/pmp. |
306696-B21 | |
| NOTE: For additional ProLiant Performance Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_div/11925_div.html | ||
| ProLiant Essentials Rapid Deployment Pack Windows Edition and Linux Edition Release | ||
| Rapid
Deployment Pack, Single-Server License NOTE: This license allows 1 server to be deployed and managed via RDP. |
267196-B21 | |
| Rapid
Deployment Pack, Single-Server License (Japan) NOTE: This license allows 1 server to be deployed and managed via RDP. |
267196-291 | |
| NOTE:
For additional ProLiant Essentials Rapid Deployment Pack License Kits please see
the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html http://h18000.www1.hp.com/products/quickspecs/11713_div/11713_div.html | ||
| ProLiant Essentials Workload Management Pack | ||
| ProLiant Essentials Workload Management Pack, Single Server License |
303284-B21 | |
| NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_div/11452_div.html | ||
| ProLiant Essentials Virtualization Management Software | ||
| ProLiant Essentials
Virtual Machine Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372214-B21 | |
| ProLiant
Essentials Server Migration Pack, Single-Migration License NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation. NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005. | 375345-B21 | |
| NOTE: For additional ProLiant Essentials Virtualization Management Software License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_div/12328_div.html | ||
| ProLiant Essentials Vulnerability and Patch Management Pack | ||
| ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
371645-B21 | |
| NOTE: For additional ProLiant Vulnerability and Patch Management Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_div/12111_div.html | ||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. | ||
| | ||
| ProLiant Software Maintenance Subscription | ProLiant Software Maintenance Subscription |
355060-B21
|
| ProLiant Software Maintenance Single Release |
356573-B21
|
|
| ProLiant Foundation Pack Single Release |
356604-B21
|
|
| NOTE: Please see
the SmartStart QuickSpecs for additional information regarding the subscription
purchase: http://h18000.www1.hp.com/products/quickspecs/division/11073.html (Worldwide) http://h18000.www1.hp.com/products/quickspecs/north_america/11073.html (North America) |
||
|
|
||
| Processor | Intel Xeon 3.0 GHz/800MHz-1MB
Processor Option Kit NOTE: This processor option kit (PN 368152-B21) supports the HP ProLiant DL360 G4 only. |
368152-B21
|
| Intel Xeon 3.4 GHz/800MHz-1MB
Processor Option Kit NOTE: This processor option kit (PN 354582-B21) supports the HP ProLiant DL360 G4 only. |
354582-B21
|
|
| Intel Xeon 3.6 GHz/800MHz-1MB
Processor Option Kit NOTE: This processor option kit (PN 354583-B21) supports the HP ProLiant DL360 G4 only. |
354583-B21
|
|
|
|
||
|
Memory |
512 MB of Advanced ECC PC2700
DDR SDRAM DIMM Memory Kit (1 x 512 MB) |
358347-B21
|
| 1024 MB of Advanced ECC PC2700
DDR SDRAM DIMM Memory Kit (1 x 1 GB) |
358348-B21
|
|
| 2048 MB of Advanced ECC PC2700 DDR SDRAM DIMM Memory Kit (1 x 2 GB) |
358349-B21
|
|
|
|
||
| Optical Drives | Slimline CD-RW/DVD-ROM Combo Option Kit |
331903-B21
|
| Slimline DVD-ROM Drive (8X/24X)
Option Kit (Servers) NOTE: This DVD-ROM Drive (PN 264007-B21) is for SCSI models. It is not supported in SATA models. |
264007-B21
|
|
| Slimline CD-ROM Drive 24X NOTE: This CD/ROM Drive (PN 356963-B21) is for SATA models. |
356963-B21
|
|
| HP DVD+R/RW 8X Slim |
383975-B21
|
|
|
|
||
| Diskette Drive | 1.44 MB Diskette Drive NOTE: This 1.44MB Diskette Drive (PN 354588-B21) is for SATA models. |
354588-B21
|
|
|
||
| Hard Drives | Ultra320 – Universal
Hot Plug NOTE: The HP ProLiant DL360 G4 only supports U320 Universal Hot Plug drives. | |
| HP 300GB U320 10K Universal HDD |
350964-B22 | |
| HP 146GB U320 10K Universal HDD |
286716-B22 | |
| HP 72GB U320 10K Universal HDD | 286714-B22 | |
| HP 146GB U320 15K Universal HDD |
347708-B22 | |
| HP 72GB U320 15K Universal HDD | 286778-B22 | |
| HP 36GB U320 15K Universal HDD |
286776-B22 | |
| NOTE:
Please see the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration, and
operating temperature: U320 Hard Drive QS: http://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.html (Worldwide) http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html (North America) | ||
| Serial-ATA
(SATA) Hard Drive (SATA Models only) NOTE: When SATA drives are installed, hot-plug capability and LEDs are currently not supported. NOTE: SATA drives have a 1 year warranty. | ||
| HP 500GB 1.5G SATA 7.2K 3.5" HDD | 395473-B21 | |
| HP 250GB 1.5G SATA 7.2K 3.5" HDD | 349239-B21 | |
| HP 160GB 1.5G SATA 7.2K 3.5" HDD | 349238-B21 | |
| HP 80GB 1.5G SATA 7.2K 3.5" HDD | 349237-B21 | |
| NOTE: Please
see the SATA Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration, and
operating temperature: | ||
| | ||
| Storage Controllers | SCSI Controllers | |
| 128MB Battery Backed Write Cache
Enabler Option Kit NOTE: Upgrade for Smart Array 6i Controller. |
346914-B21 | |
|
Smart Array 6402/128 Controller |
273915-B21 | |
|
Smart Array 6404/256 Controller |
273914-B21 | |
|
Smart Array 642 Controller |
291967-B21 | |
| 128MB
Battery-Backed Cache Enabler NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array 642 Controller. | 351580-B21 | |
| 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
284688-B21 | |
| 64-Bit/133-MHz
Dual Channel Ultra320 SCSI Adapter NOTE: For support of external drives only. |
268351-B21 | |
| Ultra320
Expansion Module for SA-6402 NOTE: For support of external drives only. |
273911-B21 | |
| 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21 | |
| NOTE:
Please see the following Controller or SCSI Adapter QuickSpecs for Technical
Specifications such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported,
SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache, RAID
support, and additional information: http://h18000.www.1.hp.com/products/quickspecs/12030_div/12030_div.html (Smart Array 6i) http://h18000.www1.hp.com/products/quickspecs/11587_div/11587_div.html (Smart Array 6400 Series) http://h18000.www1.hp.com/products/quickspecs/11563_div/11563_div.html (Smart Array 642) http://h18000.www1.hp.com/products/quickspecs/10429_div/10429_div.html (SCSI Adapter) http://h18000.www1.hp.com/products/quickspecs/11555_div/11555_div.html (U320 Adapter) http://h18000.www.1.hp.com/products/quickspecs/11943_div/11943_div.html (U320 SCSI HBA) | ||
| SAS Controller | ||
| HP Smart Array P600 Controller |
337972-B21 | |
| 512MB DDR BBWC Upgrade | 372538-B21 | |
| NOTE: Please
see the following Controller QuickSpecs for Technical Specifications such as PCI
Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak Data Transfer
Rate, Channels, SCSI Ports, Drives supported, Cache, RAID support, and additional
information: http://h18000.www1.hp.com/products/quickspecs/12247_div/12247_div.html (Smart P600 Controller) | ||
| SAS HBA | ||
| HP 8 Internal Port SAS HBA with RAID | 347786-B21 | |
NOTE: Please
see the following QuickSpecs for additional information: | ||
| | ||
| Communications | HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter |
367132-B21
|
| HP NC310F PCI-X 1000SX Gigabit Server Adapter |
368169-B21
|
|
| HP NC320T PCI Express 1000T Gigabit Server Adapter |
367047-B21
|
|
| HP NC370F PCI-X Multifunction 1000SX Gigabit Server Adapter |
374193-B22
|
|
| HP NC370T PCI-X Multifunction 1000T Gigabit Server Adapter |
374191-B22
|
|
| HP NC1020 PCI 1000T Gigabit Server Adapter |
353377-B21
|
|
| HP NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter |
313881-B21
|
|
| HP NC7771 PCI-X 1000T Gigabit Server Adapter |
290563-B21
|
|
| NOTE:
A minimum of 1 GB of memory is required for NC370x adapters, with a maximum
of two NC370x adapters permitted in a server. NOTE: Any NIC (except the NC1020) on the option list can be used for redundancy with the embedded NC7782 Dual Port Network Controller. When teaming with other NICs or with the embedded NIC, the lack of Jumbo Frames and LSO features on the NC1020 will cause high end NICs to have those features disabled. (e.g. incompatibility issues with the other option NICs for that platform). |
||
| HP NC570C PCI-X Dual-port 4x Fabric Adapter |
376158-B21
|
|
| HP NC571C PCI Express Dual-port 4x Fabric Adapter |
376160-B21
|
|
| HP 24-Port 4x Fabric Copper Switch |
376227-B21
|
|
| HP 1m 4x Fabric Copper Cable |
376232-B21
|
|
| HP 3m 4x Fabric Copper Cable |
376232-B22
|
|
| HP 5m 4x Fabric Copper Cable |
376232-B23
|
|
|
|
||
| Management Options | Remote Insight Lights-Out Edition II (NA, LA) |
227251-001 |
| Remote Insight Lights-Out Edition II (EMEA) |
227251-021 |
|
| Remote Insight Lights-Out Edition II (ROW) |
227251-371 |
|
|
|
||
| High Performance Solutions |
HPCC Myrinet Fiber NIC |
257894-006 |
| Myrinet 2XP PCI-X, Fiber, F-series, 2MB |
390456-B21
|
|
|
|
||
|
Tape Drives |
| ||||||||||||||||||||||||||||||||||||||||
| | |||||||||||||||||||||||||||||||||||||||||
| Tape Autoloaders | DAT Autoloader | |
| HP StorageWorks DAT 72x6 Autoloader (External) | Q1567A | |
| NOTE:
Please see the DAT 72x6 Tape Autoloader QuickSpecs for additional options such
as host bus adapters, controllers and media: http://h18006.www1.hp.com/products/quickspecs/11905_div/11905_div.html (Worldwide) http://h18006.www1.hp.com/products/quickspecs/11905_na/11905_na.html (North America) | ||
| HP StorageWorks 1/8 Tape Autoloader | ||
| HP StorageWorks 1/8 Ultrium 960 Tape Autoloader | AF204A | |
| HP StorageWorks 1/8 Ultrium 448 Tape Autoloader | AF203A | |
| HP StorageWorks 1/8 Ultrium 232 Tape Autoloader | AF202A | |
| 1/8 Tape Autoloader Rackmount
Kit NOTE: Required to install the 1/8 tape autoloader in a standard 19-inch rack. | C9268R | |
| NOTE: Please reference the 1/8 Tape Autoloader QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. | ||
| | ||
| Tape Libraries | HP StorageWorks MSL2024 Tape Library | |
| HP StorageWorks MSL2024 1 Ultrium 960 Drive Library | AG115A | |
| HP StorageWorks MSL2024 1 Ultrium 448 Drive Library | AG116A | |
| HP StorageWorks MSL2024 2 Ultrium 448 Drive Library | AG117A | |
| HP StorageWorks MSL6000 Tape Library | ||
| Ultrium 960 technology | ||
| HP StorageWorks MSL6030 1 Ultrium 960 Dr LVDS Library | AD606A | |
| HP StorageWorks MSL6030 1 Ultrium 960 Dr FC Library | AD608A | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr LVDS Library | AD607A | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr FC Library | AD609A | |
| Ultrium 460 technology | ||
| HP StorageWorks MSL6030 1 Ultrium 460 Dr LVDS Library | AD598A | |
| HP StorageWorks MSL6030 1 Ultrium 460 Dr FC Library | AD600A | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr LVDS Library | AD599A | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr FC Library | AD601A | |
| NOTE: Please reference the MSL2024 and MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. | ||
|
|
||
| Magneto-Optical Jukeboxes | HP StorageWorks 9.1 GB Optical Jukeboxes | |
| 600mx, 4 drive, 64 slot jukebox |
C1160M
|
|
| 1200mx, 4 drive, up to 128 slots |
C1104M
|
|
| 2200mx, 6 drive, up to 238 slots |
C1107M
|
|
| NOTE: Please see the HP StorageWorks
Magneto-Optical Products data sheet for a complete listing of available
jukeboxes at: http://www.hp.com/products1/storage/products/archivalprod/brochures/ MO_family_pb.pdf NOTE: Please reference the Magneto-Optical Jukebox data sheets at http://www.hp.com/go/optical for additional information needed to create a complete solution. |
||
|
|
||
| Ultra Density Optical Jukeboxes | 1900ux, 4 drive, 64 slot jukebox | AA966A |
| 3800ux, 4 drive, 128 slot jukebox | AA969A | |
| 7100ux, 6 drive, 238 slot jukebox | AA971A | |
| NOTE: Please see
the HP StorageWorks Ultra Density Optical Jukeboxes QuickSpecs for a complete
listing of available jukeboxes at: http://h18006.www1.hp.com/products/quickspecs/11944_div/11944_div.html NOTE: Please reference the Ultra Density Optical Jukebox QuickSpecs at http://www.hp.com/go/optical for additional information needed to create a complete solution |
||
|
|
||
| Power Cords | NOTE: The HP ProLiant DL360 G4 ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). For stand-alone deployments or installation without a rack, country-specific power cord options are available. U.S. & Japan models will ship with two power cords: IEC-IEC (142257-002) and North American C13-Nema 5-15P (103541-001) cords. | |
| Power Cord, Euro, 10A 250 V Straight (12 ft/3.7 m) |
157215-021
|
|
| Power Cord, UK, 10A 250 V Straight (12 ft/3.7 m) |
157216-031
|
|
| Power Cord, Danish, 10A 250 V Straight (12 ft/3.7 m) |
157218-081
|
|
| Power Cord, Swiss, 10A 250 V Straight (12 ft/3.7 m) |
157219-111
|
|
| Power Cord, Italian, 10A 250 V Straight (12 ft/3.7 m) |
157217-061
|
|
| Power Cord, South Africa, 10A 250 V Straight (12 ft/3.7 m) |
157220-AR1
|
|
|
|
||
| HP StorageWorks Modular Smart Array 20 | HP
StorageWorks Modular Smart Array 20 NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. | 335921-B21 |
| HP StorageWorks Modular Smart
Array 20 Starter Kit NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. Includes Smart Array 6402/128 Controller. | 366172-B21 | |
| NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 3.5" Hot Plug Hard Drives. | ||
| | ||
| HP StorageWorks Modular Smart Array 30 | HP
StorageWorks Modular Smart Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies | 302969-B21 |
| HP StorageWorks Modular Smart
Array 30 DB NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies | 302970-B21 | |
| NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 Hot Plug Hard Drives. | ||
| | ||
|
HP StorageWorks Modular Smart Array 50 |
HP StorageWorks Modular Smart Array 50 Enclosure |
364430-B21 |
| NOTE: Please see
the Modular Smart Array 50 QuickSpecs for additional information including
configuration steps and additional options needed for a complete solution
at: http://h18000.www1.hp.com/products/quickspecs/12245_na/12245_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/12245_div/12245_div.html (Worldwide) |
||
|
|
||
|
HP StorageWorks Modular Smart Array 500 |
HP StorageWorks Modular Smart Array 500 Generation 2 |
335880-B21 |
| NOTE: Please see
the Modular Smart Array 500 Generation 2 QuickSpecs for additional information
including configuration steps and additional options needed for a complete
solution at: http://h18000.www1.hp.com/products/quickspecs/11956_na/11956_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11956_div/11956_div.html (Worldwide) |
||
|
|
||
|
HP StorageWorks Modular Smart Array 1000 |
HP StorageWorks Modular Smart Array 1000 |
201723-B22 |
| NOTE: Please see
the Modular Smart Array 1000 QuickSpecs for additional options and configuration
information at http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.html (Worldwide) |
||
|
|
||
| HP StorageWorks Modular Smart Array 1500 cs | Modular Smart Array 1500 Controller Shelf |
AA986A
|
| NOTE: Please see
the StorageWorks Modular SAN Array 1500 cs QuickSpecs for additional options
and configuration information at: http://www.hp.com/go/MSA1500cs |
|
|
|
|
||
| StorageWorks Options | StorageWorks
2 Gb, 64-bit/133 MHz PCI-X-to-Fibre Channel Host Bus Adapter for Windows 2000,
Windows Server 2003 and Linux NOTE: FCA2214 2 Gb Fibre Channel Host Bus Adapter is a single channel, 64-bit/133 MHz PCI-X-to Fibre Channel Host Bus Adapter (HBA) with an embedded multi-mode optical interface |
281541-B21 |
| FCA2404DC
- HP StorageWorks 2 Gb, Dual Channel, 133 MHz PCI-X-to-Fibre Channel Host Bus
Adapter for Windows® 2000, and Windows Server 2003 NOTE: FCA2404DC HP StorageWorks 2 Gb Fibre Channel Host Bus Adapter is a dual channel, 133 MHz, PCI-X to Fibre Channel Host Bus Adapter (HBA) with an embedded multi-mode optical interface. | 323264-B21 | |
| FCA2404 - StorageWorks 2 Gb,
single channel, 133 MHz PCI-X-to-Fibre Channel Host Bus Adapter for Windows 2000,
Windows NT and Windows Server 2003 NOTE: FCA2404 StorageWorks 2 Gb, Fibre Channel Host Bus Adapter is a single channel, multi-path failover, 133 MHz, PCI-X to Fibre Channel Host Bus Adapter (HBA) with an embedded multi-mode optical interface for ProLiant Server connects |
305573-B21 | |
| StorageWorks
2 Gb, Dual Port, 64-Bit/133 MHz PCI-X-to-Fibre Channel Host Bus Adapter for W2K,
Windows Server 2003 and Linux NOTE: FCA2214DC StorageWorks 2 Gb Dual Port, Fibre Channel Host Bus Adapter is a 64-bit/133 MHz, PCI-X-to Fibre Channel Host Bus Adapter (HBA) with an embedded multi-mode optical interface. | 321835-B21 | |
| | ||
| Cluster Options | ProLiant Cluster Starter Kit | 364023-B21 |
| NOTE: For additional
information regarding the ProLiant Cluster Starter Kit please see the following
QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11935_na/11935_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11935_div/11935_div.html (Worldwide) | ||
| HP HA/F200 for Entry SAN Cluster |
364026-B22 | |
| HP HA/F200 for Entry SAN Cluster (Japan) |
364026-292 | |
| NOTE:
For additional information regarding the ProLiant Cluster for Entry Level SAN
please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11932_na/11932_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11932_div/11932_div.html (Worldwide) | ||
| ProLiant Cluster HA/F500 for the Enterprise SAN | 364024-B21 | |
| NOTE: For additional
information regarding the ProLiant Cluster HA/F500 for Enterprise SAN please see
the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11933_na/11933_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11933_div/11933_div.html (Worldwide) | ||
| HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 and Red Hat EL & 4 (2 node license cluster kit) | 305199-B26 | |
| HP Serviceguard for Linux A.11.16 for SUSE SLES9 and Red Hat EL 3 & 4 (single license version) |
307754-B26 | |
| HP Serviceguard for Linux and Red Hat Global File System - 1 year subscription | T2798AA#001 | |
| HP Serviceguard for Linux and Red Hat Global File System - 3 years subscription | T2798AA#003 | |
| NOTE: For additional
information regarding HP Serviceguard for Linux, please see the following QuickSpecs
at: http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11518_div/11518_div.html (Worldwide) | ||
| | ||
| Uninterruptible Power Systems – Rack Mountable | HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage (NA) |
204404-001 |
| HP UPS R1500 XR (1500VA, 1340 Watt), High Voltage (INTL) |
204404-B31 |
|
| HP UPS R1500 XR (1500VA, 1340 Watt), Low Voltage (JPN) |
204404-291 |
|
| HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage (NA) |
192186-001 |
|
| HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (NA) |
192186-002 |
|
| HP UPS R3000 XR (2400VA, 2250 Watt), Low Voltage (JPN) |
192186-291 |
|
| HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (JPN) |
192186-292 |
|
| HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (INTL - detachable cord) |
192186-B31 |
|
| HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A IEC309 Plug) |
192186-B32 |
|
| HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A CEE 7/7 SCHUKO Plug) |
192186-B33 |
|
| HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A BS-546 Plug) |
192186-AR1 |
|
| HP UPS R5500 XR, (5000VA, 4500 Watt), High Voltage (NA/JPN) |
326529-D71
|
|
| HP UPS R5500 XR, (6000VA, 5400 Watt), High Voltage (INTL) |
326529-B31
|
|
| HP UPS R12000 XR, N+ x (12KVA, 12KW) High Voltage (WW) |
207552-B22
|
|
|
NOTE: UPS R12000 has a hardwired input and output connection. |
|
|
|
|
||
| HP Monitored Power Distribution Unit (PDU) | HP Monitored Power Distribution Unit: Full Rack Version | |
| HP 17.3 kVA S2324 Monitored PDU- dual input, 3-phase, 24A (NA/JPN) |
370959-D71 | |
| HP 8.3 kVA S1324 Monitored PDU- single input, 3-phase, 24A (NA/JPN) |
370960-D71 | |
| HP 16.6 kVA S2140 Monitored PDU- dual input, 1-phase, 40A (NA/JPN) |
370961-D71 | |
| HP 8.6 S1140 Monitored PDU- single input, 1-phase, 40A (NA/JPN) |
370962-D71 | |
| HP 22.1 kVA S2316 Monitored PDU- dual input, 3-phase, 16A (INTL) |
370963-B31 | |
| HP 11 kVA S 1316 Monitored PDU- single input, 3-phase, 16A (INTL) |
370964-B31 | |
| HP 14.7 kVA S2132 Monitored PDU- dual input, 1-phase, 32A (INTL) |
370965-B31 | |
| HP 7.4 kVA S1132 Monitored PDU- single input, 1-phase, 32A (INTL) |
370966-B31 | |
|
| ||
|
Modular PDUs 1U/0U |
Fixed Cord Extension Bars NOTE: Two extension bar sticks; each with (7) C13 plugs. |
351655-B21
|
| Fixed Cord PDU (NA/JPN) NOTE: Four Fixed Cord Extension Bars, and one 24A, HV mPDU L6-30P core. |
351655-D72
|
|
| Fixed Cord PDU (INTL) NOTE: Four Fixed Cord Extension Bars, and one 32A, HV mPDU IEC-309 core. |
351655-B31
|
|
| HP Modular Power Distribution
Units (mPDU), Low Volt Model, 24A (100-127 VAC) (NA, Japan) NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of the UPS R3000 XR. |
252663-D71
|
|
|
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC) (NA, Japan) |
252663-D72 |
|
|
HP Modular Power Distribution Units (mPDU), High Volt Model, 32A (200-240 VAC) (Int’l) |
252663-B31 |
|
|
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240
VAC) (WW) |
252663-B21 |
|
|
HP Modular Power Distribution Unit(mPDU), High Volt Model, 16A (200-240 VAC) (WW) |
252663-B24 |
|
| HP Modular Power Distribution Unit (mPDU), High Volt Model, 40A, Attached Cord, (NA/JPN) |
252663-D73
|
|
| HP Modular Power Distribution Unit (mPDU), High Volt Model, 40A, Attached Cord, (Int'l) |
252663-B32
|
|
| NOTE: This PDU has a detachable input power cord and allows for adaptability to country specific power requirements. This model may also be used with the high volt UPSs R3000 XR and R6000 For North America, need to order cable PN 340653-001. | ||
| NOTE: Please see
the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables and country specific
power cords: http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.html (Worldwide) |
||
|
|
||
| USB Options | HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver) |
DC172B
|
| USB 1.44-MB External Diskette Drive (Carbonite) |
DC141B
|
|
| 256MB HP Drive Key II (USB 2.0) |
PH657A
|
|
|
|
||
| HP ProLiant DL360 G4 Deployment Options | 460W HP redundant power supply with IEC cord only |
354587-B21
|
| 460W HP redundant power supply
with US or Japanese NEMA cord only NOTE: The HP ProLiant DL360 G4 ships with a single IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). For stand-alone deployments or installation without a rack, country-specific power cord options are available. U.S., Japan, & APD models ship with two power cords: IEC-IEC and country-specific NEMA cords. |
354587-001
|
|
|
|
||
| Third Party Rack Kit | Rack Adapter Kit NOTE: This kit allows HP rack servers to fit in racks that are 24" wide. |
332815-B21
|
|
|
||
| Telco Rack Kit | Telco Rack Kit, ProLiant DL360 G4, Japan |
385938-291
|
|
|
||
|
HP Rack 5000 Series |
HP 5642 Rack Unassembled |
358254-B21
|
|
|
||
|
Rack Options for Rack 5000 Series |
Stabilizer Kit for 5642 rack (Graphite
Carbon) NOTE: The stabilizing kit is used to prevent rack from tipping over. |
374493-B21
|
| Baying Kit for 5642 rack (Graphite
Carbon) NOTE: The baying kit is used to join two or more HP 5642 racks. |
374499-B21
|
|
|
|
||
|
HP Rack 10000 G2 Series (Carbon/Graphite Metallic) | 10642 G2 (42U) Rack Cabinet - Pallet | AF001A |
| 10642 G2 (42U) Rack Cabinet - Shock Pallet | AF002A | |
| 10642 G2 (42U) Rack Cabinet - Crated | AF003A | |
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet | AF004A | |
| 10642 G2 (42U) Rack Cabinet, without door - Shock Pallet | AF005A | |
| 10642 G2 (42U) Rack Cabinet - with Extension, without door - Shock Pallet | AF006A | |
| 10636 G2 (36U) Rack Cabinet - Pallet | AF011A | |
| 10636 G2 (36U) Rack Cabinet - Shock Pallet | AF012A | |
| 10636 G2 (36U) Rack Cabinet - Crated | AF013A | |
| 10636 G2 (36U) Rack Cabinet , with Extension - Shock Pallet | AF014A | |
| 10636 G2 (36U) Rack Cabinet, without door - Shock Pallet | AF015A | |
| 10636 G2 (36U) Rack Cabinet, with Extension, without door - Shock Pallet | AF016A | |
| NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed. | ||
| NOTE: Please
see the Rack 10000 G2 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html (Worldwide) | ||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
| Rack Options for Rack 10000 G2 Series | HP 10642 G2 Front Door ALL | AF009A |
| HP 10636 G2 Front Door ALL | AF019A | |
| 10642 G2 (42U) Side Panels (set of two) (Graphite Metallic) | AF054A | |
| 10636 G2 (36U) Side Panels (set of two) (Graphite Metallic) | AF056A | |
| 10636 G2 Rear Extension Kit | AF060A | |
| 600mm G2 Stabilizer Option Kit (Graphite) | AF062A | |
| 600mm G2, Heavy Duty Stabilizer Option Kit (Graphite) | AF064A | |
| 800mm G2 Stabilizer Option Kit (Graphite) | AF066A | |
| 800mm G2, Heavy Duty Stabilizer
Option Kit (Graphite) NOTE: Supports 10000 G2 Series only. | AF068A | |
| HP 10000 G2 Rack Grounding Kit | AF074A | |
| 600W 10K G2 Rack Tie Down | AF076A | |
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
|
HP Rack 10000 Series | 10642 (42U) Infrastructure Rack (Low Voltage) |
379006-001 |
| 10642 (42U) Infrastructure Rack (High Voltage) |
379005-001 | |
| HP Rack S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22 | |
| HP Rack 10842 (42U, 800mm wide) – Pallet |
257415-B21 | |
| HP Rack 10842 (42U, 800mm wide) – Shock Pallet |
257415-B22 | |
| HP Rack 10647 (47U) – Pallet |
245160-B21 | |
| HP Rack 10647 (47U) – Crated |
245160-B23 | |
| HP Rack 10642 (42U) – Pallet |
245161-B21 | |
| HP Rack 10642 (42U) – Shock Pallet |
245161-B22 | |
|
HP Rack 10642 (42U) – Crated |
245161-B23 | |
| HP Rack 10636 (36U) – Pallet |
245162-B21 | |
| HP Rack 10636 (36U) – Shock Pallet |
245162-B22 | |
| HP Rack 10636 (36U) – Crated |
245162-B23 | |
| HP Rack 10622 (22U) – Pallet |
245163-B21 | |
| HP Rack 10622 (22U) – Shock Pallet |
245163-B22 | |
| HP Rack 10622 (22U) – Crated |
245163-B23 | |
|
NOTE: -B21 (pallet) used to ship
empty racks shipped on a truck |
| |
|
NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. Not all HP equipment is qualified to be shipped in the Rack 10000 series |
| |
|
NOTE: Please see the Rack 10000 QuickSpecs
for Technical Specifications such as height, width, depth, weight, and color: |
| |
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. |
| |
|
| ||
|
Rack Options for Rack 10000 Series | HP Rack Light Kit (Neon) | 361589-B21 | |||||||||||||||||||||||||||
| HP Rack Plinth Kit (Carbon) |
251960-B21 | ||||||||||||||||||||||||||||
| 42U Side Panel - Graphite Metallic |
246099-B21 | ||||||||||||||||||||||||||||
| 36U Side Panel - Graphite Metallic |
246102-B21 | ||||||||||||||||||||||||||||
| 47U Side Panel - Graphite Metallic |
255486-B21 | ||||||||||||||||||||||||||||
| TFT7210R
Rack Mounted 17" Monitor NOTE: For a complete list of Monitors please view the following URL: http://www.hp.com/go/kvm. | 348373-B21 | ||||||||||||||||||||||||||||
| TFT5600 Rack Keyboard Monitor NOTE: For a complete list of Monitors please view the following URL: http://h18004.www1.hp.com/products/monitors/. |
221546-xx1 | ||||||||||||||||||||||||||||
| 1U Rack Keyboard & Drawer (Carbon) |
257054-xx1 | ||||||||||||||||||||||||||||
| Country Code Key (for TFT5600 Rack Keyboard Monitor (PN 221546-xx1 and for 1U Rack Keyboard & Drawer (PN 257054-xx1) | |||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | |||||||||||||||||||||||||||||
| | |||||||||||||||||||||||||||||
|
HP KVM Switch Options |
IP Console Switch Box (KVM/IP), 3 x 1 x 16 |
262586-B21
|
| IP Console Switch Box (KVM/IP), 1 x 1 x 16 |
262585-B21
|
|
| Server Console Switch (KVM), 0 x 1 x 8 port |
336044-B21
|
|
| Server Console Switch (KVM), 0 x 2 x 16 port |
336045-B21
|
|
| PS/2 Interface Adapter, 1 pack |
262588-B21
|
|
| PS/2 Interface Adapter, 8 pack |
262587-B21
|
|
| USB Interface Adapter, 1 pack |
336047-B21
|
|
| Serial Interface adapter - 1 Pack with power supply |
373035-B21
|
|
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x 4 USB/PS2 KVM Switch, TT (NA/JPN) |
371301-D71
|
|
| HP 1x 4 USB/PS2 KVM Switch, TT (AU/NZ) |
371301-011
|
|
| HP 1x 4 USB/PS2 KVM Switch, TT (UK) |
371301-031
|
|
| HP 1x 4 USB/PS2 KVM Switch, TT (EU) |
371301-A21
|
|
| HP 1x 4 USB/PS2 KVM Switch, RM (ALL) |
371302-B21
|
|
| HP PS2 KVM Cable with audio, 6', 2-pack |
371730-B21
|
|
| HP USB KVM Cable with audio, 6', 2-pack |
371729-B21
|
|
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
|
HP Serial Console Server Options |
HP 16 Port Serial Console Server (worldwide) |
AF101A
|
| HP 48 Port Serial Console Server (worldwide) |
AF102A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack |
AF103A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack |
AF110A
|
|
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| Service and Support Offerings (HP Care Pack Services) |
|
|
|
Memory
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
|
HP ProLiant DL360 G4 3.06 GHz and 3.4 GHz-1MB Models |
|
Standard Memory Upgrading Memory and Memory Interleaving Standard Memory Plus Optional Memory |
|
Memory |
Slot |
||||
|
1 |
2 |
3 |
4 |
||
|
Standard |
1 GB
|
1 GB
|
Empty
|
Empty
|
Empty
|
|
Optional |
6 GB
|
1 GB
|
1 GB
|
2 GB
|
2 GB
|
|
Maximum
|
8 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
|
Following are memory options available from HP: |
|
|
358347-B21 |
|
358348-B21 |
|
358349-B21 |
|
HP ProLiant DL360 G4 3.4 GHz-1MB RPS Models |
|
Standard Memory Standard Memory Replaced with Optional Memory |
|
Memory |
Slot |
||||
|
1 |
2 |
3 |
4 |
||
|
Standard |
2 GB
|
1 GB
|
1 GB
|
Empty
|
Empty
|
|
Optional |
6 GB
|
1 GB
|
1 GB
|
2 GB
|
2 GB
|
|
Maximum
|
8 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
|
Following are memory options available from HP: |
|
|
358347-B21 |
|
358348-B21 |
|
358349-B21 |
|
|
Storage
![]() |
1,0 | 2 x 1 inch Ultra320 Hot Pluggable Hard Drive Bays; SATA model also available |
| A | 1.44-MB Diskette Drive (removeable) | |
| B | Low-Profile 24x IDE CD-ROM (ejectable) | |
| Drive Support | |||
| | |||
|
Quantity |
Position |
| |
|
Removable Media | |||
| 1.44-MB Diskette Drive | Up to 1 | A | Integrated |
|
24x IDE CD-ROM Drive | Up to 1 | B | Integrated IDE |
| Slimline DVD-Rom Drive (8x/24x) Option Kit (Servers) | Up to 1 | B | Integrated IDE |
| | |||
| Hard Drives | |||
| Ultra320
Hot Pluggable Drives NOTE: The HP ProLiant DL360 G4 only supports U320 Universal drives. | |||
|
Quantity Supported |
Position Supported |
Controller | |
| 300GB
U320 10K 146.8GB U320 10K 72.8GB U320 10K 146.8GB U320 15K 72.8GB U320 15K 36.4GB U320 15K | Up to 2 | 0-1 |
Smart Array 6i Controller (integrated on system board) NOTE: The HP ProLiant DL360 Generation 4 (G4) does not offer an external SCSI port. Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 642 Controller 64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter |
| | |||
| Serial-ATA
(SATA) Hard Drive NOTE: When SATA drives are installed, Hot-plug capability and LEDs are only supported when a Serial ATA Smart Array option card has been installed. | |||
| Quantity |
Position |
| |
| 80GB
1.5G SATA 7.2K 160GB 1.5G SATA 7.2K 250GB 1.5G SATA 7.2K 500GB 1.5G SATA 7.2K | Up to 2 | 0-1 |
HP embedded 2 Port SATA Controller with RAID 0/1 support |
| | |||
|
External Storage |
||||
|
Quantity |
Position |
|
||
|
Modular Smart Array20 Family |
Please see the Modular Smart Array 20 QuickSpecs to determine configuration requirements |
External |
Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 642 Controller 64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
| Modular Smart Array 30 Family | Please see the Modular Smart Array 30 QuickSpecs to determine configuration requirements. | External | Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 642 Controller 64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
| Modular Smart Array 50 Enclosure | 2 | External | HP Smart Array P600 Controller | |
| Modular Smart Array 500 G2 System | 1 | External | Smart Array 642 Controller (used
as Host Bus Adapter) Please see the Modular Smart Array 500 G2 QuickSpecs for the latest list of supported HBAs: http://www.hp.com/go/msa500 |
|
| Modular Smart Array 1000 | Please see the Modular Smart Array 1000 QuickSpecs below to determine configuration requirements | External | Please see the Modular Smart Array 1000 QuickSpecs (URL below) for the latest list of supported HBAs | |
| Modular Smart Array 1500 cs | Please see the Modular Smart Array 1500 cs QuickSpecs below to determine configuration requirements | External | Please see the Modular Smart Array 1500 cs QuickSpecs (URL below) for the latest list of supported HBAs | |
| Modular Smart Array 1000: http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.html
(Worldwide) http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html (North America) Modular Smart Array 1500 cs: http://www.hp.com/go/MSA1500cs |
||||
|
|
||||
| Tape Drives, Tape Autoloaders, & Tape Libraries | ||||
|
NOTE: For an up-to-date listing of the latest
O/S Support details for each of the Tape Drives listed below, please see the following: | ||||
| Quantity Supported | Position Supported | Controller | ||
| HP
StorageWorks Tape Drives, External Ultrium 232 Ultrium 448 Ultrium 460 DAT 40 DAT 72 DLT VS80 DLT VS160 SDLT 320 | Up to 2 | External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS | |
| HP StorageWorks Tape Drives,
External DAT 72 USB DAT 40 USB | Up to 2 | External | USB Port | |
| HP StorageWorks Tape Drives,
External Ultrium 960 SDLT 600 | 1 | External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS | |
| HP StorageWorks Autoloaders,
External DAT 72x6 Tape Autoloader 1/8 Tape Autoloader | 1 per SCSI channel | External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS | |
| HP StorageWorks Rack-mount
Tape Drive Enclosures 1U Rack-Mount Kit 3U Rack-Mount Kit 5U Rack-Mount Kit | 1 per SCSI channel | External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS | |
| HP StorageWorks Tape Libraries,
External MSL2024 (Ultrium 960-based) MSL2024 (Ultrium 448-based) MSL6000 (Ultrium 960 -based) MSL6000 (SDLT 600-based) MSL6000 (Ultrium 460 -based) MSL5026S2 (SDLT 320-based) MSL5052S2 (SDLT 320-based) | Please reference the MSL Tape Library QuickSpecs to determine configuration requirements | External | Please
consult the EBS connectivity matrix at http://www.hp.com/go/ebs
for detailed connectivity information. | |
|
|
Power Specifications
| To review typical system
power ratings use the Active Answers Power Calculator which is available
via the online tool located at URL: http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
To drill down to calculators: |
|
|
Technical Specifications
| System Unit | Dimensions (H x W x D) | 1.70 x 16.78 x 27.75 in (4.32 x 42.62 x 70.49 cm) | |
| Weight | Maximum (two hard drives installed, two power supply, two processor) | 37 lb (16.78 kg) | |
| No hard drives installed, one power supply, one processor | 27.5 lb (12.47 kg) | ||
| Input Requirements |
Rated Input Voltage | 100 to 240 VAC | |
| Rated Input Current | 5.85 Amps (100 V) to 2.85 Amps (200 V) | ||
| Rated Input Frequency | 50 to 60 Hz | ||
| Rated Input Power | 585 W (100VAC) to 565 W (200VAC)
NOTE: 585 W of Rated Input Power is for the Maximum Peak Output Power of 460 W. |
||
| BTU Rating |
2000 BTU/HR NOTE: The BTU rating listed is for the Rated Input Power of 585 W. |
||
| Power Specifications | To review typical system power
ratings use the Power Calculator which is available via the online tool
located at URL: http://h30099.www3.hp.com/configurator/calc /Power%20Calculator%20Catalog.xls To drill down to calculators: |
||
| Power Supply Output Power
(per power supply) |
Rated Steady-State Power | 460 W | |
| Temperature Range | Operating | 10° to 35°C at sea level with an altitude derating of 1.0°C per every 300m (1000ft) above sea level to a maximum of 3000m (10,000ft), no direct sustained sunlight. Maximum rate of change is 10°C/Hr. | |
| Storage | -30° to 60°C - Maximum rate of change is 20°C/Hr. | ||
| Relative Humidity
(non-condensing) |
Operating | 10 to 90% relative humidity (Rh), 28°C maximum wet bulb temperature | |
| Storage | 5 to 95% relative humidity (Rh), 38.7°C maximum wet bulb temperature | ||
| Maximum Wet Bulb Temperature |
38.7° C | ||
| SCSI Connectors | No external VHDCI connector | ||
| Acoustic Noise | Idle (Fixed Disk Drives Spinning) |
||
L WAd (BELS) |
6.6 | ||
L pAm (dBA) |
50 | ||
| Operating (Random Seeks to Fixed Disks) |
|||
L WAd (BELS) |
6.9 BELS | ||
L pAm (dBA) |
53 dBA | ||
|
|
|||
| Smart Array 6i Controller (integrated on system board) | Data Compatible with all Smart Array Controllers | Yes |
| Instant Upgrades to other Smart Array Controllers | Yes | |
| Consistent Software Manageability Tools | Yes | |
| PCI-X Bus | 64-bit/133-MHz | |
| PCI-X Peak Data Transfer Rate | 1066 MB/s | |
| SCSI Protocols Supported | Ultra320, Ultra3, Ultra2 | |
| SCSI Peak Data Transfer Rate | 320 MB/s per channel NOTE: For ProLiant servers having TWO internal drive bays on separate SCSI ports: SCSI Peak Data Transfer Rate is 320 MB/s; 160 MB/s per channel and Channels is 2 |
|
| Channels | 1 | |
| SCSI Ports (external/internal) |
0/1 | |
| Drives Supported (maximum) |
2 drives | |
| Cache | 64 MB Read Cache | |
| Battery-Backed Write Cache | Yes, with installation of Battery-Backed Write Cache Enabler, up to 128MB | |
| RAID Support | 0, 1, 1+0, 5 | |
| Logical Drives (maximum) |
32 Logical Drives | |
| Online Configuration | Yes | |
| Online Capacity Expansion | Yes | |
| Logical Drive Capacity Extension | Yes | |
| Online Stripe Size Migration | Yes | |
| Online RAID Level Migration | Yes | |
| Online Spare Support | Yes | |
| Automatic Data Recovery | Yes | |
| Drive Roaming | Yes | |
|
|
||
| Embedded NC7782 Dual Port NIC | Network Interface | 10/100/1000-T | |
| Compatibility | EEE 802.3 10Base-T IEEE 802.3ab 1000Base-T IEEE 802.3u 100Base-TX |
||
| Data Transfer Method | 64-bit/66MHz PCI-X | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Full and Half-Duplex) | 2000 Mb/s | ||
| Connector | RJ-45 | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP up to 328 ft (100 m) | |
| 10/100/1000 Base-TX | Category 5 UTP up to 328 ft (100 m) | ||
|
|
|||
| ©
Copyright 2006 Hewlett-Packard Development Company, L.P. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |