Overview
|
HP ProLiant BL30p Server Blade
|
| What's New |
|
|
|
| At A Glance |
NOTE: All ATA hard drives offered by
HP carry a one year warranty regardless of the base system in which they
are installed. |
| |
|
|
|
|
||||||||||||
|
|
||||||||||||||||||||||||||||
| Configuration Steps |
|
|
|
HP BladeSystem p-Class Enhanced Server Blade Enclosures
Installed in 42U Rack
Redundant Power Configuration (left) and Non-Redundant Power Configurations (right)
|
||||||
|
|
Standard Features (Server Blade)
| Processor | Intel Xeon Processor 3.2-GHz/533-MHz with 2MB L3 cache |
| Intel Xeon Processor 3.2-GHz/533-MHz with 1MB L3 cache | |
| Intel Xeon Processor 3.06-GHz/533-MHz with 512KB L2 cache | |
|
|
|
| Upgradeability | HP ProLiant BL30p Server Blade is dual-processor capable |
|
|
|
| Cache
Memory One of the following depending on Model |
2-MB Level 3 cache |
| 1-MB Level 3 cache | |
| 512-KB Level 2 cache | |
|
|
|
| Chipset | ServerWorks GC-LE chipset NOTE: For more information regarding the ServerWorks chipset, see the following website: http://www.serverworks.com/products/overview.html |
| | |
| Memory Protection | Memory interleaving when an identical pair of DIMMs is installed (P/N 287494-B21) |
|
|
|
| Memory | Type |
PC2100 DDR SDRAM running at 266MHz |
| Standard | 1024-MB (1 x 1-GB) NOTE: non-interleaved unless a second DIMM option installed 287497-B21 |
|
| Maximum | 4-GB | |
|
|
||
| Network Adapter | Three (3) network adapters total: |
| Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE | |
| One 10/100T NIC (embedded) dedicated to iLO management | |
|
|
|
| Integrated Manageability | Integrated Lights-Out (iLO)
Management Advanced Pack with new static IP bay configuration feature iLO integrated HP BladeSystem wizard simplifies iLO, blade server and operating system installation and configuration. |
|
|
|
| Internal Storage | Hard Drives | None ship standard |
|
|
||
| Maximum Internal Storage | ATA |
120-GB (2 x 60-GB small form factor ATA, 5400rpm hard drives) |
|
|
||
| Fiber Channel on
the HP ProLiant BL30p server blade |
The following items are needed to connect the HP ProLiant BL30p server blade to a SAN via Fibre Channel: |
| 1. HP ProLiant BL30p server blade with Dual-Port Fibre Channel Adapter (option) installed | |
|
|
| 2A. RJ-45 Patch Panel 2 (with Fibre Channel pass through) interconnect option | |
|
|
| 2B. C-GbE2 or F-GbE2 or CGESM Interconnect Kit plus the Storage Connectivity Kit (option) | |
AND |
|
| 3. Compatible SAN | |
|
|
|
|
|
| Local I/O Cable | No PCI slots, all features integrated |
| Two (2) USB ports, one (1) video port, one (1) iLO port and one (1) serial port | |
| Two (2) Local I/O cables ship with each server blade enclosure with enhanced backplane components (281404-B22 and 243564-B22) | |
| NOTE: Tested USB devices (keyboard, mouse, floppy) are listed in options section below. |
|
|
Standard Features (Server Blade Enclosure and Interconnects)
| HP BladeSystem p-Class Enhanced Server Blade Enclosures and ProLiant BL p-Class Interconnects | |
| HP BladeSystem p-Class Enhanced Server Blade Enclosure | 6U (10.5-inch), 19-inch wide |
|
Holds up to:
|
|
|
NOTE: HP BladeSystem p-Class enhanced
server blade enclosures are required to support HP ProLiant BL30p server
blades. See compatibility matrix: http://www.hp.com/go/bladesystem/enclosure/compatibility. |
|
| Two (2) outside bays for interconnects (Patch Panel, Patch Panel 2, GbE Interconnect Switch, GbE2, or CGESM Interconnect Switch) | |
| Server blade management module on the rear of the server blade enclosure is hot-plug, has a centralized 10/100T iLO port for all installed blades, reports events of all installed blades and provides asset and inventory information via SNMP. | |
|
|
|
| HP BladeSystem p-Class Power Requirements |
Redundant 208V 30amp 3-phase
4 wire, NA Redundant 380 - 415V 20A 3-phase 5 wire, Intl NOTE: 3 phase power highly recommended for BL30p deployments. Redundant 200V - 240V AC, 30 amp single-phase for NA and International Redundant -48VDC ± 10% |
|
|
|
| ProLiant
BL p-Class Interconnect Switch Option (A pair of switches per kit) (Each HP BladeSystem p-Class server blade enclosure requires a pair of
interconnects - patch panels or interconnect switches) |
Interconnect Switch interconnects
consolidate the Ethernet signals from the server blades to a smaller set
of external copper-based or fiber-based uplink ports for connection to the
network infrastructure. Like the Patch Panel interconnects, an option is
also available to pass through individual HP ProLiant BL20p G2 and HP ProLiant
BL30p Fibre Channel signals. The interconnect switches provide up to a 32-to-1
server network cable reduction per server enclosure depending on the mix
of HP ProLiant BL20p server blade series, HP ProLiant BL30p server blade
series, and HP ProLiant BL40p server blades series. Each interconnect switch
pair reduces up to sixteen internal server network (NIC) ports to one to
six external ports (four on a modular rear mounting interconnect and two
on the switch front panel). This provides a total of twelve external ports
per server blade enclosure. The Cisco GESM and GbE2 Interconnect Kits (C-GbE2 and F-GbE2) are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) and HP ProLiant BL30p Fibre Channel pass-through. |
|
The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kit is
for applications that require network adapter consolidation to 1000 Mbps
(Gigabit Ethernet) in a Cisco infrastructure. The CGESM supports the same
and HP ProLiant BL30p Fibre Channel pass-through as the GbE2.
|
|
|
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) provide NIC consolidation to 1000 Mbps (Gigabit Ethernet), advanced network feature, Fibre Channel pass-through (for HP ProLiant BL20p server blade series and HP ProLiant BL30p server blades series), and 1 Gigabit Ethernet bandwidth connectivity to the network.
|
|
|
The GbE Interconnect Kits (C-GbE and F-GbE) provide NIC consolidation to 100 Mbps (Fast Ethernet).
|
|
| Also included (per Interconnect Switch): | |
| |
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).
| |
| ProLiant BL Interconnect Switch Management System and Utilities: | |
| Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing of speed and duplex mode, and more. | |
| | |
| ProLiant BL p-Class Storage
Connectivity Kit Option (supports a pair of two CGESM or GbE2 switches) |
The Storage Connectivity Kit
(option) is required for Fibre Channel signal pass-through when using the
CGESM or a GbE2 Interconnect Switch Kit. Both Ethernet cable consolidation
and Fibre Channel connectivity is possible using a single interconnect option.
Order one Storage Connectivity Kit per server blade enclosure for Fibre
Channel pass through of HP ProLiant BL20p and HP ProLiant BL30p server blades
series. The Storage Connectivity Kit includes two OctalFC Interconnect Modules that provide sixteen open transceiver cages for the pluggable small form factor transceivers that come with each HP ProLiant BL30p Dual-Port Fibre Channel Adapter (option) and each HP ProLiant BL20p Dual Port Fibre Channel Adapter. The Storage Connectivity Kit supports up to eight HP ProLiant BL20p server blade series, up to sixteen HP ProLiant BL30p server blades series or combinations thereof. |
|
|
|
| ProLiant
BL p-Class RJ-45 Patch Panel (A pair of patch panels provided per kit) (Each server blade enclosure requires a pair of interconnects - patch panels or interconnect switches) |
6U (10.5-inch), plugs into HP BladeSystem p-Class server blade enclosures. |
| Passes through Ethernet NIC signals, from all installed server blades, individually out as RJ-45 connections. | |
| Supports Gigabit Ethernet network adapters. | |
| 16 RJ-45 connectors on the back of each RJ-45 Patch Panel (32 RJ-45 connections per server blade enclosure). | |
| The benefits to the RJ-45 Patch
Panel are that it: - Allows the customer to connect signals to their own LAN infrastructure components. - Provides very economical option enabling the lowest cost blade solution. - Is completely passive and requires no software or management. |
|
|
|
|
| ProLiant BL p-Class
RJ-45 Patch Panel 2 (with Fibre Channel pass through) (A pair of patch panels provided per kit) (Each server blade enclosure requires a pair of interconnects - patch panels or interconnect switches) NOTE: Either Patch Panel 2 or a Switch Interconnect Kit is required for SAN connectivity with HP ProLiant BL20p server blade series and HP ProLiant BL30p server blades series. |
6U (10.5-inch), plugs into HP BladeSystem p-Class server blade enclosures | |
| Passes through Ethernet NIC signals, from all installed server blades, individually out as RJ-45 connections. | ||
| Supports Gigabit Ethernet network adapters. | ||
| 16 RJ-45 connectors on the back of each RJ-45 Patch Panel 2 (32 RJ-45 connections per server blade enclosure). | ||
| Passes through Fibre Channel signals, from all installed HP ProLiant BL20p and HP ProLiant BL30p server blades series, individually out through small form factor pluggable (SPF) transceiver cages. | ||
| Supports 2 Gb/s Fibre Channel signals and backward compatible with existing 1 Gb/s Fibre Channel equipment. | ||
| 8 Fibre Channel small form factor pluggable (SPF) transceiver cages on the front of each Patch Panel 2 (16 Fibre Channel SPF transceiver cages per server blade enclosure). | ||
| The benefits to
the RJ-45 Patch Panel 2 are that it: - Allows the customer to connect signals to their own LAN and SAN infrastructure components. - Provides a very economical option enabling the lowest cost blade solution. - Is completely passive and requires no software or management. - Electrically isolates the Ethernet and Fibre Channel signals from each other. |
||
|
|
||
| ProLiant BL p-Class Fibre Channel pass through | Fibre Channel signals travel from a HP ProLiant BL20p server blade series and/or HP ProLiant BL30p server blades series through the server blade enclosure backplane. Fibre Channel signals are terminated through the RJ-45 Patch Panel 2 CGESM or GbE2 Interconnect Switch (with Storage Connectivity Kit) in the interconnect bays. To provide redundancy each server blade has two Fibre Channel signals; one Fibre Channel signal terminates through the right interconnect, the other Fibre Channel signal terminates through the left interconnect. |
| Eight Fibre Channel small form factor pluggable (SPF) transceiver cages exist on the front of each RJ-45 Patch Panel 2 and rear of each GbE2 Interconnect Switch (16 Fibre Channel connections per server blade enclosure). The SPF cages are used for insertion of SPF transceivers included with the HP ProLiant BL20p G2 Dual-port Fibre Channel Mezzanine Card and the HP ProLiant BL30p Dual-Port Fibre Channel Adapter. | |
|
|
|
| Required Network Cabling | 10Base-T | Categories 3, 4 or 5 UTP (100
meters) EIA/TIA-568 100-ohm STP (100 meters) |
| 100Base-TX | Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) |
|
| 1000Base-T | Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) |
|
| 1000Base-SX | 50/125 µm Multimode Fiber,
400 MHz/Km (500 meters) 50/125 µm Multimode Fiber, 500 MHz/Km (550 meters) 62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters) 62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters) |
|
| NOTE: For cabling information, refer to the website at: http://www.hp.com/go/servers/. | ||
|
|
Standard Features (Power System and Rack Information)
| HP BladeSystem p-class Power System and Rack Information |
NOTE: To determine power configuration, please refer to the HP BladeSystem p-Class Overview and Planning Whitepaper and sizing utility at http://www.hp.com/products/servers/proliant-bl/p-class/info/. |
|
|
|
| HP BladeSystem p-Class 3U Power Enclosure | 3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), dual input single phase and three phase models available. |
|
HP BladeSystem p-Class 3U power enclosure provides scalable rack-centralized,
hot-plug power without the need for PDUs. |
|
| Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, Facility DC Power Connection kit (240563-B21) is needed. | |
|
|
|
| HP BladeSystem p-Class 1U Power Enclosure | 1U (1.75-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Multi-input single phase or three phase operation. |
|
HP BladeSystem p-Class 1U power enclosure provides external, hot-plug
power. Each 1U power enclosure houses up to six hot-plug power supplies
to power up to one server blade enclosure, fully populated with BL p-Class
server blades and interconnects. |
|
| Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed. | |
|
|
|
| HP BladeSystem p-Class Power Distribution (only required with 3U power enclosures) | In the HP BladeSystem p-Class infrastructure, redundant -48 VDC power (from the power enclosures or facility DC power) is carried from the power enclosures to the server blade enclosures through bus bars (for multiple enclosures) or power bus boxes (for a single enclosure). Hinges attach the HP BladeSystem bus bars to the rack rails and provide easy rear access to the blade enclosures and interconnects. Power is distributed through independent A- and B-sided bus bars. | ||
|
Three power distribution solutions are available depending on the size of the intended deployment (see table). |
|||
|
Power Enclosures Supported
|
Server Blade Enclosures Supported
|
Max. Rack Space Occupied
|
|
| Scalable Bus Bar |
1 or 2
|
up to 5
|
36U
|
| Mini Bus Bar |
1 or 2*
|
up to 3
|
24U
|
| Power Bus Box |
1
|
1
|
9U
|
| NOTE*:
Dual power input kit for mini bus bar option (364565-B21) required to support
two power enclosures. NOTE: To support a full 42U rack of BL p-Class server blades, use two stacked pairs of mini bus bars. |
|||
| Required Power Source |
Two 30-Amp redundant power feeds per power enclosure
|
| For cabling information, refer to the website at: http://www.hp.com/go/servers/ | |
|
|
Standard Features (Manageability)
|
ProLiant Essentials Foundation Pack Software for the ProLiant BL Server |
|
|||||||
|
||||||||
|
||||||||
| NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials | ||||||||
|
|
||||||||
| Optional ProLiant Essentials Value Packs |
Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs:
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. |
|
|
|
| SmartStart | SmartStart is a tool that simplifies
single server setup, providing a rapid way to deploy reliable and consistent
server configurations. To obtain a copy of SmartStart for your blade server,
redeem the coupon that is included with your Blade server or order your
copy from the SmartStart web site. For more information, please visit the
SmartStart Web site at http://www.hp.com/servers/smartstart. SmartStart version supported (minimum): SmartStart 6.20 |
|
|
|
| OS Support |
Microsoft® Windows® NOTE: For a more complete and up-to-date
listing of supported operating systems and versions, please visit our
OS Support Matrices website: http://www.hp.com/go/ossupport |
|
| |
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA3000 & EVA5000, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
|
| |
| Intelligent Manageability |
Integrated Lights-Out (iLO) Advanced Pack |
NOTE: For more information on iLO Advanced visit the website: http://www.hp.com/servers/ilo/ |
|
| Automatic Server Recovery-2
(ASR-2) Redundant ROM Remote Flash ROM ROM Based Setup Utility (RBSU) Advanced Configuration and Power Interface Specification Ready (ACPI) Server and Interconnect Switch Health Logs Redundant Power Supply Utility Pre-Failure Warranty (covers processors, as well as hard drives and memory) Interconnect Switch Management System and Utilities (Interconnect Switch option) Integrated Management Log (IML) Dynamic sector repairing and drive parameter tracking (with Smart Array controllers) Network adapter teaming set-up utility |
|
|
|
|
| HP BladeSystem p-Class Availability Features |
|
|
Interconnect Switch availability features:
|
|
|
|
|
| Security | Power-on password Administrator's password Integrated Lights-Out provides user authentication via directory services or 12 customizable user accounts Integration Lights-Out supports SSH and SSL encryption Integrated Lights-Out can be disabled via a Global Setting Interconnect switch multilevel user names and passwords, management interface time out period setting, SSH*, SCP secure copy protocol*, port-based IEEE 802.1Q tagged VLANs, RADIUS user authentication and authorization*, and IP address restriction *NOTE: CGESM or GbE2 Interconnect Switch only |
|
|
|
| Minimum Rack Requirements | Mounts in ProLiant, and Telco racks and Third Party racks that meet the following criteria: |
|
|
| NOTE: If using Compaq 7000 Series rack, Rack Extension Kit and High Air Flow Rack Door options are required. | |
|
|
|
| Rack Airflow Requirements |
|
| CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: | |
|
|
| CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. | |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section on the HP ProLiant BL30p server blade website: http://www.hp.com/servers/bl30p. | |
|
|
|
| Service and Support |
Three-year limited warranty, including hardware diagnostic support, pre-failure
warranty (coverage of processors, memory and SCSI hard drives). The warranty
is fully supported by HP Services and a worldwide network of resellers
and service providers. In addition 90-day's getting started software telephone
support may be covered under the warranty or available for an additional
fee. Enhancements to warranty services are available through HP Care Pack
services. Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware and software services are available including:
HP has introduced a new building block approach which allows customers
to purchase the right coverage at the right time whether purchasing an
initial server blade plus enclosure or purchasing additional ProLiant
server blades over time. HP will offer two sets of Care Pack services,
one designed to support the server blade and one designed to support the
enclosure. |
| NOTE:
For more information on HP Care Pack services, contact any of our worldwide
sales offices or resellers or visit our worldwide Web site on the internet
at: http://www.hp.com/hps/carepack NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at: http://www.hp.com/hps NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html |
|
|
Models
| HP ProLiant BL30p
X3.2-2MB, 1GB (2P) 360329-B21 |
Processor(s) | Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported) |
| Cache Memory | 2-MB Level 3 writeback per processor | |
| Memory | 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz (1 x 1-GB); 2-way interleaved when an identical pair installed | |
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (embedded) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-class blade sleeve. Blade sleeve supports 1 or 2 HP ProLiant BL30p server blades. Blade sleeve plugs vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure. | |
|
|
||
| ProLiant BL30p
X3.2-1MB, 1GB (2P) 368271-B21 |
Processor(s) | Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported) |
| Cache Memory | 1-MB Level 3 writeback per processor | |
| Memory | 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz (1 x 1-GB); 2-way interleaved when an identical pair installed | |
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (embedded) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-class blade sleeve. Blade sleeve supports 1 or 2 HP ProLiant BL30p server blades. Blade sleeve plugs vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure. | |
|
|
||
| ProLiant BL30p
X3.06/533MHz-512KB, 1GB (2P) 354566-B21 |
Processor(s) | Two (2) Intel Xeon 3.06-GHz standard (up to 2 supported) |
| Cache Memory | 512-KB Level 2 writeback per processor | |
| Memory | 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266MHz (1 x 1-GB), 2-way interleaved when an identical pair installed | |
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (embedded) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120-GB maximum (with optional hard drives) 2 x 60-GB | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-class blade sleeve. Blade sleeve supports 1 or 2 HP ProLiant BL30p server blades. Blade sleeve plugs vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure. | |
|
|
||
| ProLiant BL30p
X3.06/533MHz-512KB, 1GB (1P) 354050-B21 |
Processor(s) | One (1) Intel Xeon 3.06-GHz standard (up to 2 supported) |
| Cache Memory | 512-KB Level 2 writeback per processor | |
| Memory | 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz (1 x 1-GB), 2-way interleaved when an identical pair installed | |
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (embedded) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-class blade sleeve. Blade sleeve supports 1 or 2 HP ProLiant BL30p server blades. Blade sleeve plugs vertically into ProLiant BL p-Class Enhanced Server Blade Enclosure. | |
|
|
||
| ProLiant 3.2-GHz
BL30p Server Blade Multi-Pack 368272-B21 NOTE: Multi-pack contains 8 HP ProLiant BL30p server blades, 4 HP ProLiant BL30p server blade sleeves and 8 licenses for Rapid Deployment Pack. |
Processor(s) | Each blade is configured with Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported) |
| Cache Memory | 2-MB Level 3 writeback per processor | |
| Memory | 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz (1 x 1-GB), 2-way interleaved when identical pair installed | |
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (embedded) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120-GB maximum (with optional hard drives) 2 x 60-GB | |
|
|
||
|
ProLiant 3.06-GHz BL30p Server Blade Multi-Pack |
Processor(s) | Each blade is configured with Two (2) Intel Xeon 3.06-GHz standard (up to 2 supported) |
| Cache Memory | 512-KB Level 2 writeback per processor | |
| Memory | 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz (1 x 1-GB), 2-way interleaved when identical pair installed | |
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (embedded) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120-GB maximum (with optional hard drives) 2 x 60-GB |
|
|
Configuration Information - Factory Integrated Models (North America only)
| NOTE:
For Configure to Order requirements within EMEA region, please consult local
Sales Contact. NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis. NOTE: This product offering does not support HP Factory Express Server Configuration Level 1. |
||
| Step 1: Base Server Blade Configuration | ||
| Model | HP ProLiant BL30p
Configurable Model (North America) |
367243-405
|
| Configurable Model
ships with: - Two embedded NC7781 PCI-X Gigabit NICs plus one 10/100T NIC for iLO - Integrated Lights-Out (iLO) Management with Advanced Pack features |
||
|
|
||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processor | Intel Xeon 3.06GHz/512-KB
cache Processor Kit (option) NOTE: If 2 processors are desired, select one 354053-L21and one 354053-B21 |
354053-L21
|
| Intel Xeon 3.2GHz/533-1M
cache Processor Kit (option) NOTE: If 2 processors are desired, select one 368273-L21and one 368273-B21 |
368273-L21
|
|
| Intel Xeon 3.2GHz/533-2M
cache Processor Kit (option) NOTE: If 2 processors are desired, select one 364306-L21and one 364306-B21 |
364306-L21
|
|
|
|
||
| Memory | NOTE:
Two-way interleaving memory is enabled when an identical pair of DIMMs
is installed. |
|
| For 1GB Total
Memory choose A or B: |
||
| A) 2 x 512 MB PC2100
DDR SDRAM DIMMs |
300679-B21
|
|
| B) 1 x 1GB PC2100 DDR SDRAM DIMM |
287497-B21
|
|
|
For 2GB Total Memory choose two: |
||
| 1 x 1GB PC2100 DDR SDRAM DIMM |
287497-B21
|
|
| For 4GB Total
Memory: |
||
| 2 x 2048MB PC2100 DDR SDRAM DIMM 2x2048 |
300682-B21
|
|
|
|
||
| Step 3: Choose Additional Options for Factory Integration | ||
| Hard Drive | ATA Hard Drive Kit
for ProLiant BL35p and ProLiant BL30p, 2.5" parallel ATA drive, 60GB,
5400 rpm |
354052-B21
|
| Fibre Channel Option | Dual-Port Fibre Channel Adapter (2-Gb) Kit for HP ProLiant BL30p or HP ProLiant BL35p server blades |
354054-B21
|
| NOTE: For additional options, including HP BladeSystem p-Class blade sleeve, enhanced server blade enclosure, interconnect options and power subsystem options, please refer to the "Options" section below. | ||
|
|
Options
| NOTE: Some options may not be factory integratable. Please contact your local sales representative for additional information. | ||
| Unique Options | ATA Hard Drive Kit for ProLiant BL35p and ProLiant BL30p, 2.5" parallel ATA drive, 60GB, 5400 rpm (option) |
354052-B21 |
| HP BladeSystem p-Class Blade Sleeve Kit (option) |
354101-B21
|
|
| NOTE: Each blade sleeve supports one or two HP ProLiant BL30p/HP ProLiant BL35p server blades. | ||
|
|
||
| ProLiant BL30p/BL35p Dual-Port Fibre Channel Adapter | Emulex-based Dual Port Fibre Channel
Adapter (2-Gb) Kit (option) NOTE: Supports the HP ProLiant 25p/30p/35p/45p Server Blades |
394588-B21
|
| Dual-Port Fibre Channel Adapter
(2-Gb) Kit (option) for HP ProLiant BL30p or HP ProLiant BL35p server blades* NOTE: This Fibre-Channel adapter is Qlogic-based *NOTE: When using this adapter, Patch Panel 2, CGESM, or a GbE2 Interconnect Switch Kit (with Storage Connectivity Kit) must be used to provide pass through of the Fibre Channel signals. |
354054-B21
|
|
|
|
||
|
ProLiant Essentials Value Pack Software |
ProLiant Essentials Vulnerability and Patch Management Pack, 1-Server + 10 Desktop Bundle License |
389941-B21
|
| ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License |
371645-B21
|
|
| ProLiant Essentials Vulnerability and Patch Management Pack, 10-Server License |
372029-B21
|
|
| ProLiant Essentials Vulnerability and Patch Management Pack, Flexible-Quantity License |
371646-B21
|
|
| ProLiant Essentials Vulnerability and Patch Management Pack, Tracking License for New Servers |
371647-B21
|
|
| ProLiant Essentials Vulnerability and Patch Management Pack, Tracking License for Installed servers |