Overview
|
HP ProLiant BL30p Server Blade
|
| What's New |
|
|
|
| At A Glance |
NOTE: All ATA hard drives offered by
HP carry a one year warranty regardless of the base system in which they
are installed. |
| |
|
|
|
|
||||||||||||
|
|
||||||||||||||||||||||||||||
| Configuration Steps |
|
|
|
HP BladeSystem p-Class Enhanced Server Blade Enclosures
Installed in 42U Rack
Redundant Power Configuration (left) and Non-Redundant Power Configurations (right)
|
||||||
|
|
Standard Features (Server Blade)
| Processor | Intel Xeon Processor 3.2-GHz/533-MHz with 2MB L3 cache |
| Intel Xeon Processor 3.2-GHz/533-MHz with 1MB L3 cache | |
| Intel Xeon Processor 3.06-GHz/533-MHz with 512KB L2 cache | |
|
|
|
| Upgradeability | HP ProLiant BL30p Server Blade is dual-processor capable |
|
|
|
| Cache
Memory One of the following depending on Model |
2-MB Level 3 cache |
| 1-MB Level 3 cache | |
| 512-KB Level 2 cache | |
|
|
|
| Chipset | ServerWorks GC-LE chipset NOTE: For more information regarding the ServerWorks chipset, see the following website: http://www.serverworks.com/products/overview.html |
| | |
| Memory Protection | Memory interleaving when an identical pair of DIMMs is installed (P/N 287494-B21) |
|
|
|
| Memory | Type |
PC2100 DDR SDRAM running at 266MHz |
| Standard | 1024-MB (1 x 1-GB) NOTE: non-interleaved unless a second DIMM option installed 287497-B21 |
|
| Maximum | 4-GB | |
|
|
||
| Network Adapter | Three (3) network adapters total: |
| Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE | |
| One 10/100T NIC (embedded) dedicated to iLO management | |
|
|
|
| Integrated Manageability | Integrated Lights-Out (iLO)
Management Advanced Pack with new static IP bay configuration feature iLO integrated HP BladeSystem wizard simplifies iLO, blade server and operating system installation and configuration. |
|
|
|
| Internal Storage | Hard Drives | None ship standard |
|
|
||
| Maximum Internal Storage | ATA |
120-GB (2 x 60-GB small form factor ATA, 5400rpm hard drives) |
|
|
||
| Fiber Channel on
the HP ProLiant BL30p server blade |
The following items are needed to connect the HP ProLiant BL30p server blade to a SAN via Fibre Channel: |
| 1. HP ProLiant BL30p server blade with Dual-Port Fibre Channel Adapter (option) installed | |
|
|
| 2A. RJ-45 Patch Panel 2 (with Fibre Channel pass through) interconnect option | |
|
|
| 2B. C-GbE2 or F-GbE2 or CGESM Interconnect Kit plus the Storage Connectivity Kit (option) | |
AND |
|
| 3. Compatible SAN | |
|
|
|
|
|
| Local I/O Cable | No PCI slots, all features integrated |
| Two (2) USB ports, one (1) video port, one (1) iLO port and one (1) serial port | |
| Two (2) Local I/O cables ship with each server blade enclosure with enhanced backplane components (281404-B22 and 243564-B22) | |
| NOTE: Tested USB devices (keyboard, mouse, floppy) are listed in options section below. |
|
|
Standard Features (Server Blade Enclosure and Interconnects)
| HP BladeSystem p-Class Enhanced Server Blade Enclosures and ProLiant BL p-Class Interconnects | |
| HP BladeSystem p-Class Enhanced Server Blade Enclosure | 6U (10.5-inch), 19-inch wide |
|
Holds up to:
|
|
|
NOTE: HP BladeSystem p-Class enhanced
server blade enclosures are required to support HP ProLiant BL30p server
blades. See compatibility matrix: http://www.hp.com/go/bladesystem/enclosure/compatibility. |
|
| Two (2) outside bays for interconnects (Patch Panel, Patch Panel 2, GbE Interconnect Switch, GbE2, or CGESM Interconnect Switch) | |
| Server blade management module on the rear of the server blade enclosure is hot-plug, has a centralized 10/100T iLO port for all installed blades, reports events of all installed blades and provides asset and inventory information via SNMP. | |
|
|
|
| HP BladeSystem p-Class Power Requirements |
Redundant 208V 30amp 3-phase
4 wire, NA Redundant 380 - 415V 20A 3-phase 5 wire, Intl NOTE: 3 phase power highly recommended for BL30p deployments. Redundant 200V - 240V AC, 30 amp single-phase for NA and International Redundant -48VDC ± 10% |
|
|
|
| ProLiant
BL p-Class Interconnect Switch Option (A pair of switches per kit) (Each HP BladeSystem p-Class server blade enclosure requires a pair of
interconnects - patch panels or interconnect switches) |
Interconnect Switch interconnects
consolidate the Ethernet signals from the server blades to a smaller set
of external copper-based or fiber-based uplink ports for connection to the
network infrastructure. Like the Patch Panel interconnects, an option is
also available to pass through individual HP ProLiant BL20p G2 and HP ProLiant
BL30p Fibre Channel signals. The interconnect switches provide up to a 32-to-1
server network cable reduction per server enclosure depending on the mix
of HP ProLiant BL20p server blade series, HP ProLiant BL30p server blade
series, and HP ProLiant BL40p server blades series. Each interconnect switch
pair reduces up to sixteen internal server network (NIC) ports to one to
six external ports (four on a modular rear mounting interconnect and two
on the switch front panel). This provides a total of twelve external ports
per server blade enclosure. The Cisco GESM and GbE2 Interconnect Kits (C-GbE2 and F-GbE2) are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) and HP ProLiant BL30p Fibre Channel pass-through. |
|
The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kit is
for applications that require network adapter consolidation to 1000 Mbps
(Gigabit Ethernet) in a Cisco infrastructure. The CGESM supports the same
and HP ProLiant BL30p Fibre Channel pass-through as the GbE2.
|
|
|
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) provide NIC consolidation to 1000 Mbps (Gigabit Ethernet), advanced network feature, Fibre Channel pass-through (for HP ProLiant BL20p server blade series and HP ProLiant BL30p server blades series), and 1 Gigabit Ethernet bandwidth connectivity to the network.
|
|
|
The GbE Interconnect Kits (C-GbE and F-GbE) provide NIC consolidation to 100 Mbps (Fast Ethernet).
|
|
| Also included (per Interconnect Switch): | |
| |
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).
| |
| ProLiant BL Interconnect Switch Management System and Utilities: | |
| Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing of speed and duplex mode, and more. | |
| | |
| ProLiant BL p-Class Storage
Connectivity Kit Option (supports a pair of two CGESM or GbE2 switches) |
The Storage Connectivity Kit
(option) is required for Fibre Channel signal pass-through when using the
CGESM or a GbE2 Interconnect Switch Kit. Both Ethernet cable consolidation
and Fibre Channel connectivity is possible using a single interconnect option.
Order one Storage Connectivity Kit per server blade enclosure for Fibre
Channel pass through of HP ProLiant BL20p and HP ProLiant BL30p server blades
series. The Storage Connectivity Kit includes two OctalFC Interconnect Modules that provide sixteen open transceiver cages for the pluggable small form factor transceivers that come with each HP ProLiant BL30p Dual-Port Fibre Channel Adapter (option) and each HP ProLiant BL20p Dual Port Fibre Channel Adapter. The Storage Connectivity Kit supports up to eight HP ProLiant BL20p server blade series, up to sixteen HP ProLiant BL30p server blades series or combinations thereof. |
|
|
|
| ProLiant
BL p-Class RJ-45 Patch Panel (A pair of patch panels provided per kit) (Each server blade enclosure requires a pair of interconnects - patch panels or interconnect switches) |
6U (10.5-inch), plugs into HP BladeSystem p-Class server blade enclosures. |
| Passes through Ethernet NIC signals, from all installed server blades, individually out as RJ-45 connections. | |
| Supports Gigabit Ethernet network adapters. | |
| 16 RJ-45 connectors on the back of each RJ-45 Patch Panel (32 RJ-45 connections per server blade enclosure). | |
| The benefits to the RJ-45 Patch
Panel are that it: - Allows the customer to connect signals to their own LAN infrastructure components. - Provides very economical option enabling the lowest cost blade solution. - Is completely passive and requires no software or management. |
|
|
|
|
| ProLiant BL p-Class
RJ-45 Patch Panel 2 (with Fibre Channel pass through) (A pair of patch panels provided per kit) (Each server blade enclosure requires a pair of interconnects - patch panels or interconnect switches) NOTE: Either Patch Panel 2 or a Switch Interconnect Kit is required for SAN connectivity with HP ProLiant BL20p server blade series and HP ProLiant BL30p server blades series. |
6U (10.5-inch), plugs into HP BladeSystem p-Class server blade enclosures | |
| Passes through Ethernet NIC signals, from all installed server blades, individually out as RJ-45 connections. | ||
| Supports Gigabit Ethernet network adapters. | ||
| 16 RJ-45 connectors on the back of each RJ-45 Patch Panel 2 (32 RJ-45 connections per server blade enclosure). | ||
| Passes through Fibre Channel signals, from all installed HP ProLiant BL20p and HP ProLiant BL30p server blades series, individually out through small form factor pluggable (SPF) transceiver cages. | ||
| Supports 2 Gb/s Fibre Channel signals and backward compatible with existing 1 Gb/s Fibre Channel equipment. | ||
| 8 Fibre Channel small form factor pluggable (SPF) transceiver cages on the front of each Patch Panel 2 (16 Fibre Channel SPF transceiver cages per server blade enclosure). | ||
| The benefits to
the RJ-45 Patch Panel 2 are that it: - Allows the customer to connect signals to their own LAN and SAN infrastructure components. - Provides a very economical option enabling the lowest cost blade solution. - Is completely passive and requires no software or management. - Electrically isolates the Ethernet and Fibre Channel signals from each other. |
||
|
|
||
| ProLiant BL p-Class Fibre Channel pass through | Fibre Channel signals travel from a HP ProLiant BL20p server blade series and/or HP ProLiant BL30p server blades series through the server blade enclosure backplane. Fibre Channel signals are terminated through the RJ-45 Patch Panel 2 CGESM or GbE2 Interconnect Switch (with Storage Connectivity Kit) in the interconnect bays. To provide redundancy each server blade has two Fibre Channel signals; one Fibre Channel signal terminates through the right interconnect, the other Fibre Channel signal terminates through the left interconnect. |
| Eight Fibre Channel small form factor pluggable (SPF) transceiver cages exist on the front of each RJ-45 Patch Panel 2 and rear of each GbE2 Interconnect Switch (16 Fibre Channel connections per server blade enclosure). The SPF cages are used for insertion of SPF transceivers included with the HP ProLiant BL20p G2 Dual-port Fibre Channel Mezzanine Card and the HP ProLiant BL30p Dual-Port Fibre Channel Adapter. | |
|
|
|
| Required Network Cabling | 10Base-T | Categories 3, 4 or 5 UTP (100
meters) EIA/TIA-568 100-ohm STP (100 meters) |
| 100Base-TX | Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) |
|
| 1000Base-T | Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) |
|
| 1000Base-SX | 50/125 µm Multimode Fiber,
400 MHz/Km (500 meters) 50/125 µm Multimode Fiber, 500 MHz/Km (550 meters) 62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters) 62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters) |
|
| NOTE: For cabling information, refer to the website at: http://www.hp.com/go/servers/. | ||
|
|
Standard Features (Power System and Rack Information)
| HP BladeSystem p-class Power System and Rack Information |
NOTE: To determine power configuration, please refer to the HP BladeSystem p-Class Overview and Planning Whitepaper and sizing utility at http://www.hp.com/products/servers/proliant-bl/p-class/info/. |
|
|
|
| HP BladeSystem p-Class 3U Power Enclosure | 3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), dual input single phase and three phase models available. |
|
HP BladeSystem p-Class 3U power enclosure provides scalable rack-centralized,
hot-plug power without the need for PDUs. |
|
| Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, Facility DC Power Connection kit (240563-B21) is needed. | |
|
|
|
| HP BladeSystem p-Class 1U Power Enclosure | 1U (1.75-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Multi-input single phase or three phase operation. |
|
HP BladeSystem p-Class 1U power enclosure provides external, hot-plug
power. Each 1U power enclosure houses up to six hot-plug power supplies
to power up to one server blade enclosure, fully populated with BL p-Class
server blades and interconnects. |
|
| Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed. | |
|
|
|
| HP BladeSystem p-Class Power Distribution (only required with 3U power enclosures) | In the HP BladeSystem p-Class infrastructure, redundant -48 VDC power (from the power enclosures or facility DC power) is carried from the power enclosures to the server blade enclosures through bus bars (for multiple enclosures) or power bus boxes (for a single enclosure). Hinges attach the HP BladeSystem bus bars to the rack rails and provide easy rear access to the blade enclosures and interconnects. Power is distributed through independent A- and B-sided bus bars. | ||
|
Three power distribution solutions are available depending on the size of the intended deployment (see table). |
|||
|
Power Enclosures Supported
|
Server Blade Enclosures Supported
|
Max. Rack Space Occupied
|
|
| Scalable Bus Bar |
1 or 2
|
up to 5
|
36U
|
| Mini Bus Bar |
1 or 2*
|
up to 3
|
24U
|
| Power Bus Box |
1
|
1
|
9U
|
| NOTE*:
Dual power input kit for mini bus bar option (364565-B21) required to support
two power enclosures. NOTE: To support a full 42U rack of BL p-Class server blades, use two stacked pairs of mini bus bars. |
|||
| Required Power Source |
Two 30-Amp redundant power feeds per power enclosure
|
| For cabling information, refer to the website at: http://www.hp.com/go/servers/ | |
|
|
Standard Features (Manageability)
|
ProLiant Essentials Foundation Pack Software for the ProLiant BL Server |
|
|||||||
|
||||||||
|
||||||||
| NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials | ||||||||
|
|
||||||||
| Optional ProLiant Essentials Value Packs |
Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs:
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. |
|
|
|
| SmartStart | SmartStart is a tool that simplifies
single server setup, providing a rapid way to deploy reliable and consistent
server configurations. To obtain a copy of SmartStart for your blade server,
redeem the coupon that is included with your Blade server or order your
copy from the SmartStart web site. For more information, please visit the
SmartStart Web site at http://www.hp.com/servers/smartstart. SmartStart version supported (minimum): SmartStart 6.20 |
|
|
|
| OS Support |
Microsoft® Windows® NOTE: For a more complete and up-to-date
listing of supported operating systems and versions, please visit our
OS Support Matrices website: http://www.hp.com/go/ossupport |
|
| |
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA3000 & EVA5000, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
|
| |
| Intelligent Manageability |
Integrated Lights-Out (iLO) Advanced Pack |
NOTE: For more information on iLO Advanced visit the website: http://www.hp.com/servers/ilo/ |
|
| Automatic Server Recovery-2
(ASR-2) Redundant ROM Remote Flash ROM ROM Based Setup Utility (RBSU) Advanced Configuration and Power Interface Specification Ready (ACPI) Server and Interconnect Switch Health Logs Redundant Power Supply Utility Pre-Failure Warranty (covers processors, as well as hard drives and memory) Interconnect Switch Management System and Utilities (Interconnect Switch option) Integrated Management Log (IML) Dynamic sector repairing and drive parameter tracking (with Smart Array controllers) Network adapter teaming set-up utility |
|
|
|
|
| HP BladeSystem p-Class Availability Features |
|
|
Interconnect Switch availability features:
|
|
|
|
|
| Security | Power-on password Administrator's password Integrated Lights-Out provides user authentication via directory services or 12 customizable user accounts Integration Lights-Out supports SSH and SSL encryption Integrated Lights-Out can be disabled via a Global Setting Interconnect switch multilevel user names and passwords, management interface time out period setting, SSH*, SCP secure copy protocol*, port-based IEEE 802.1Q tagged VLANs, RADIUS user authentication and authorization*, and IP address restriction *NOTE: CGESM or GbE2 Interconnect Switch only |
|
|
|
| Minimum Rack Requirements | Mounts in ProLiant, and Telco racks and Third Party racks that meet the following criteria: |
|
|
| NOTE: If using Compaq 7000 Series rack, Rack Extension Kit and High Air Flow Rack Door options are required. | |
|
|
|
| Rack Airflow Requirements |
|
| CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: | |
|
|
| CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. | |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section on the HP ProLiant BL30p server blade website: http://www.hp.com/servers/bl30p. | |
|
|
|
| Service and Support |
Three-year limited warranty, including hardware diagnostic support, pre-failure
warranty (coverage of processors, memory and SCSI hard drives). The warranty
is fully supported by HP Services and a worldwide network of resellers
and service providers. In addition 90-day's getting started software telephone
support may be covered under the warranty or available for an additional
fee. Enhancements to warranty services are available through HP Care Pack
services. Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware and software services are available including:
HP has introduced a new building block approach which allows customers
to purchase the right coverage at the right time whether purchasing an
initial server blade plus enclosure or purchasing additional ProLiant
server blades over time. HP will offer two sets of Care Pack services,
one designed to support the server blade and one designed to support the
enclosure. |
| NOTE:
For more information on HP Care Pack services, contact any of our worldwide
sales offices or resellers or visit our worldwide Web site on the internet
at: http://www.hp.com/hps/carepack NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at: http://www.hp.com/hps NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html |
|
|
Models
| HP ProLiant BL30p
X3.2-2MB, 1GB (2P) 360329-B21 |
Processor(s) | Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported) |
| Cache Memory | 2-MB Level 3 writeback per processor | |
| Memory | 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz (1 x 1-GB); 2-way interleaved when an identical pair installed | |
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (embedded) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-class blade sleeve. Blade sleeve supports 1 or 2 HP ProLiant BL30p server blades. Blade sleeve plugs vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure. | |
|
|
||
| ProLiant BL30p
X3.2-1MB, 1GB (2P) 368271-B21 |
Processor(s) | Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported) |
| Cache Memory | 1-MB Level 3 writeback per processor | |
| Memory | 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz (1 x 1-GB); 2-way interleaved when an identical pair installed | |
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (embedded) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-class blade sleeve. Blade sleeve supports 1 or 2 HP ProLiant BL30p server blades. Blade sleeve plugs vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure. | |
|
|
||
| ProLiant BL30p
X3.06/533MHz-512KB, 1GB (2P) 354566-B21 |
Processor(s) | Two (2) Intel Xeon 3.06-GHz standard (up to 2 supported) |
| Cache Memory | 512-KB Level 2 writeback per processor | |
| Memory | 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266MHz (1 x 1-GB), 2-way interleaved when an identical pair installed | |
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (embedded) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120-GB maximum (with optional hard drives) 2 x 60-GB | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-class blade sleeve. Blade sleeve supports 1 or 2 HP ProLiant BL30p server blades. Blade sleeve plugs vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure. | |
|
|
||
| ProLiant BL30p
X3.06/533MHz-512KB, 1GB (1P) 354050-B21 |
Processor(s) | One (1) Intel Xeon 3.06-GHz standard (up to 2 supported) |
| Cache Memory | 512-KB Level 2 writeback per processor | |
| Memory | 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz (1 x 1-GB), 2-way interleaved when an identical pair installed | |
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (embedded) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120-GB maximum (with optional hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-class blade sleeve. Blade sleeve supports 1 or 2 HP ProLiant BL30p server blades. Blade sleeve plugs vertically into ProLiant BL p-Class Enhanced Server Blade Enclosure. | |
|
|
||
| ProLiant 3.2-GHz
BL30p Server Blade Multi-Pack 368272-B21 NOTE: Multi-pack contains 8 HP ProLiant BL30p server blades, 4 HP ProLiant BL30p server blade sleeves and 8 licenses for Rapid Deployment Pack. |
Processor(s) | Each blade is configured with Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported) |
| Cache Memory | 2-MB Level 3 writeback per processor | |
| Memory | 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz (1 x 1-GB), 2-way interleaved when identical pair installed | |
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (embedded) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120-GB maximum (with optional hard drives) 2 x 60-GB | |
|
|
||
|
ProLiant 3.06-GHz BL30p Server Blade Multi-Pack |
Processor(s) | Each blade is configured with Two (2) Intel Xeon 3.06-GHz standard (up to 2 supported) |
| Cache Memory | 512-KB Level 2 writeback per processor | |
| Memory | 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz (1 x 1-GB), 2-way interleaved when identical pair installed | |
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (embedded) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120-GB maximum (with optional hard drives) 2 x 60-GB |
|
|
Configuration Information - Factory Integrated Models (North America only)
| NOTE:
For Configure to Order requirements within EMEA region, please consult local
Sales Contact. NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis. NOTE: This product offering does not support HP Factory Express Server Configuration Level 1. |
||
| Step 1: Base Server Blade Configuration | ||
| Model | HP ProLiant BL30p
Configurable Model (North America) |
367243-405
|
| Configurable Model
ships with: - Two embedded NC7781 PCI-X Gigabit NICs plus one 10/100T NIC for iLO - Integrated Lights-Out (iLO) Management with Advanced Pack features |
||
|
|
||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processor | Intel Xeon 3.06GHz/512-KB
cache Processor Kit (option) NOTE: If 2 processors are desired, select one 354053-L21and one 354053-B21 |
354053-L21
|
| Intel Xeon 3.2GHz/533-1M
cache Processor Kit (option) NOTE: If 2 processors are desired, select one 368273-L21and one 368273-B21 |
368273-L21
|
|
| Intel Xeon 3.2GHz/533-2M
cache Processor Kit (option) NOTE: If 2 processors are desired, select one 364306-L21and one 364306-B21 |
364306-L21
|
|
|
|
||
| Memory | NOTE:
Two-way interleaving memory is enabled when an identical pair of DIMMs
is installed. |
|
| For 1GB Total
Memory choose A or B: |
||
| A) 2 x 512 MB PC2100
DDR SDRAM DIMMs |
300679-B21
|
|
| B) 1 x 1GB PC2100 DDR SDRAM DIMM |
287497-B21
|
|
|
For 2GB Total Memory choose two: |
||
| 1 x 1GB PC2100 DDR SDRAM DIMM |
287497-B21
|
|
| For 4GB Total
Memory: |
||
| 2 x 2048MB PC2100 DDR SDRAM DIMM 2x2048 |
300682-B21
|
|
|
|
||
| Step 3: Choose Additional Options for Factory Integration | ||
| Hard Drive | ATA Hard Drive Kit
for ProLiant BL35p and ProLiant BL30p, 2.5" parallel ATA drive, 60GB,
5400 rpm |
354052-B21
|
| Fibre Channel Option | Dual-Port Fibre Channel Adapter (2-Gb) Kit for HP ProLiant BL30p or HP ProLiant BL35p server blades |
354054-B21
|
| NOTE: For additional options, including HP BladeSystem p-Class blade sleeve, enhanced server blade enclosure, interconnect options and power subsystem options, please refer to the "Options" section below. | ||
|
|
Options
| NOTE: Some options may not be factory integratable. Please contact your local sales representative for additional information. | ||
| Unique Options | ATA Hard Drive Kit for ProLiant BL35p and ProLiant BL30p, 2.5" parallel ATA drive, 60GB, 5400 rpm (option) |
354052-B21 |
| HP BladeSystem p-Class Blade Sleeve Kit (option) |
354101-B21
|
|
| NOTE: Each blade sleeve supports one or two HP ProLiant BL30p/HP ProLiant BL35p server blades. | ||
|
|
||
| ProLiant BL30p/BL35p Dual-Port Fibre Channel Adapter | Emulex-based Dual Port Fibre Channel
Adapter (2-Gb) Kit (option) NOTE: Supports the HP ProLiant 25p/30p/35p/45p Server Blades |
394588-B21
|
| Dual-Port Fibre Channel Adapter
(2-Gb) Kit (option) for HP ProLiant BL30p or HP ProLiant BL35p server blades* NOTE: This Fibre-Channel adapter is Qlogic-based *NOTE: When using this adapter, Patch Panel 2, CGESM, or a GbE2 Interconnect Switch Kit (with Storage Connectivity Kit) must be used to provide pass through of the Fibre Channel signals. |
354054-B21
|
|
|
|
||
|
ProLiant Essentials Value Pack Software |
ProLiant Essentials Vulnerability and Patch Management Pack, 1-Server + 10 Desktop Bundle License |
389941-B21
|
| ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License |
371645-B21
|
|
| ProLiant Essentials Vulnerability and Patch Management Pack, 10-Server License |
372029-B21
|
|
| ProLiant Essentials Vulnerability and Patch Management Pack, Flexible-Quantity License |
371646-B21
|
|
| ProLiant Essentials Vulnerability and Patch Management Pack, Tracking License for New Servers |
371647-B21
|
|
| ProLiant Essentials Vulnerability and Patch Management Pack, Tracking License for Installed servers |
378372-B21
|
|
| ProLiant Essentials Server Migration Pack, 25 - Server License |
391674-B21
|
|
| ProLiant Essentials Server Migration Pack, 50 - Server License |
391675-B21
|
|
| ProLiant Essentials Server Migration Pack, 100 - Server License |
391676-B12
|
|
| ProLiant Essentials Server Migration
Pack, 10 - Server License NOTE: This license allows 10 servers to be migrated from a physical server to 10 virtual machines. Or this license can be used to migrate 10 virtual machines from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005. |
390739-B21
|
|
| ProLiant Essentials Server Migration Pack, Single-Server License |
375345-B21
|
|
| ProLiant Essentials Server Migration Pack, Flexible-Quantity License |
375346-B21
|
|
| ProLiant Essentials Server Migration Pack, Tracking license |
375347-B21
|
|
| ProLiant Essentials Virtual Machine
Management Pack, SINGLE LIC IP CCAO- WGR |
372214-B21
|
|
| ProLiant Essentials Virtual Machine Management Pack, FLEX LIC IP CCAO-WGR |
372215-B21
|
|
| ProLiant Essentials Virtual Machine Management Pack, TRACKING LIC IP CCAO-WGR |
372216-B21
|
|
| ProLiant Essentials Performance
Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
306696-B21
|
|
| ProLiant Essentials Performance
Management Pack, 10-Server License NOTE: For use with up to 10 servers. Contains 10 licenses with one unique license activation key and documentation. |
374055-B21
|
|
| ProLiant Essentials Performance
Management Pack, Flexible-Quantity License NOTE: For use with multiple servers. This part number can be used to purchase multiple licenses with a single activation key. The quantity ordered of this part number will be the quantity of licenses included in the kit in the form of a corresponding activation key. Use the same key to activate all licenses in the actual quantity ordered. For a given order, one kit will be delivered with activation key, and documentation. |
306697-B21
|
|
| ProLiant Essentials Performance
Management Pack, Tracking license NOTE: For use with signed and implemented Activation Key Agreements only. Purchase of this part number entitles the customer to deploy additional licenses of the product under the terms of the existing Activation Key Agreement. NOTE: Nothing is delivered in conjunction with the purchase of this part number. Visit http://h18004.www1.hp.com/products/servers/proliantessentials/license/akalic.html for more information on Activation Key Agreements. |
306698-B21
|
|
| Rapid Deployment Pack, 10 User, V1.x |
269817-B21
|
|
| Rapid Deployment Pack, 10 User, V1.x (Japan) |
269817-291
|
|
| NOTE:
The above license allows 10 servers to be managed and deployed via the Deployment
Server. NOTE: Not necessary if you purchase the HP ProLiant BL30p Multi-Pack (354051-B21) or server blade enclosure with 8 Rapid Deployment Pack licenses 281404-B22. NOTE: Rapid Deployment pack is now available in a Linux Edition for Linux-only environments. |
||
| Rapid Deployment Pack, 1 User, V1.x |
267196-B21
|
|
| Rapid Deployment Pack, 1 User, V1.x (Japan) |
267196-291
|
|
| NOTE:
The above license allows 1 server to be managed and deployed via the Deployment
Server. NOTE: Not necessary if you purchase the HP ProLiant BL30p Multi-Pack (354051-B21) or server blade enclosure with 8 Rapid Deployment Pack licenses 281404-B22. NOTE: Rapid Deployment pack is now available in a Linux Edition for Linux-only environments. |
||
| Flexible Quantity License Kit |
302127-B21
|
|
| License-Only - for use with a Master License Agreement |
302128-B21
|
|
| ProLiant Essentials Intelligent
Networking Pack, Single Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372906-B21
|
|
| ProLiant Essentials Intelligent
Networking Pack, Flexible License NOTE: For use with multiple servers. This part number can be used to purchase multiple licenses with a single activation key. The quantity ordered for this part number will be the quantity of licenses included in the kit in the form of a corresponding activation key. Use the same key to activate all licenses in the actual quantity ordered. For a given order, one kit will be delivered with the activation key, and documentation. |
372950-B21
|
|
| ProLiant Essentials Intelligent
Networking Pack, Tracking License NOTE: For use with signed and implemented Activation Key Agreements only. Purchase of this part number entitles the customer to deploy additional licenses of the product under the terms of the existing Activation Key Agreement. NOTE: Nothing is delivered in conjunction with the purchase of this part number. Visit http://h18004.www1.hp.com/products/servers/proliantessentials/license/akalic.html for more information on Activation Key Agreements. |
372951-B21
|
|
| ProLiant Essentials Workload Management Pack (Featuring Resource Partitioning Manager version 2.0) |
303284-B21
|
|
| NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://hp.com/servers/proliantessentials. | ||
| NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to URL http://hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. | ||
|
|
||
| Processor | Intel Xeon 3.06-GHz / 512-KB cache Processor Kit (option) |
354053-B21
|
| NOTE: There is no option kit offered for the HP ProLiant BL30p server blade with Intel Xeon 3.2GHz processor because all models ship with two processors installed. | ||
|
|
||
| Memory (SDRAM DIMMs) |
4096-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 2-GB) |
300682-B21
|
| 2048MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 1 GB) |
300680-B21
|
|
| 2048 MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (1 x 2048 MB) |
301044-B21
|
|
| 1024-MB
of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (1 x 1-GB) NOTE: This DIMM option is an identical match to the DIMM installed on the HP ProLiant BL30p server blade base model and therefore provides 2-way interleaving when installed on a base model HP ProLiant BL30p server blade. |
287497-B21
|
|
| 1024-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 512-MB) |
300679-B21
|
|
|
|
||
| HP BladeSystem p-Class
Enhanced Server Blade Enclosures |
HP BladeSystem p-Class Enhanced
Server Blade Enclosure with the HP BladeSystem Management Suite NOTE: Includes an HP BladeSystem p-Class Enhanced Server Blade Enclosure, a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM). |
380625-B22
|
| HP BladeSystem Management Suite
(Software Licenses Only) NOTE: Adds 8 licenses to ProLiant BL p-Class Server Blade Enclosure with the HP BladeSystem Management Suite ,P/N 380625-B22 (above) for a total of 16 for a fully populated enclosure of BL30p blades. Includes a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM). |
389403-B21
|
|
| HP BladeSystem p-Class Enhanced Server Blade Enclosure (includes enhanced backplane components) |
243564-B22 |
|
| HP BladeSystem p-Class Enhanced
Server Blade Enclosure with eight (8) ProLiant Essentials Rapid Deployment
Pack Licenses (includes enhanced backplane components) NOTE: HP BladeSystem p-Class enhanced server blade enclosures are required to support HP ProLiant BL30p server blades. |
281404-B22
|
|
| HP BladeSystem p-Class Server
Blade Enclosure Upgrade Kit (option) NOTE: Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support HP ProLiant BL30p server blades series and provide a single, physical iLO port for the enclosure. |
354100-B21
|
|
|
|
||
| HP BladeSystem p-Class Interconnects | ProLiant BL p-Class Patch Panel 2 Kit with Fibre Channel pass-through (pair) |
306465-B21 |
| NOTE: Only one interconnect kit required per server blade enclosure. | ||
| ProLiant BL p-Class Patch Panel (pair) |
230766-B21
|
|
| NOTE: Only one interconnect kit required per server blade enclosure. | ||
| ProLiant BL p-Class C-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadT2 Interconnect Modules) |
283192-B21
|
|
| NOTE: Only one interconnect kit required per server blade enclosure. | ||
| ProLiant BL p-Class F-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadSX Interconnect Modules) |
283193-B21
|
|
| NOTE: Only one interconnect kit required per server blade enclosure. | ||
| Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit only |
378926-B21
|
|
| NOTE:
Two CGESM interconnect kits required per server blade enclosure. |
||
| Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit (populated with two RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules |
378927-B21 |
|
| NOTE: Two CGESM interconnect kits required per server blade enclosure. | ||
| Cisco RJ-45 10/100/1000 T/TX/T SFP Module |
378928-B21
|
|
| Cisco Fiber SX SFP
Module |
378929-B21
|
|
| ProLiant BL p-Class Storage Connectivity Kit (with pair of OctalFC Interconnect Modules and two Fibre Channel signal conditioning cards) |
321745-B21
|
|
| NOTE:
Required for HP ProLiant BL30p and HP ProLiant BL35p Fibre Channel signal
pass through when using the CGESM or GbE2 Interconnect Switch. NOTE: Only one Storage Connectivity Kit required per each GbE2 Interconnect Kit. NOTE: Only one Storage Connectivity Kit required for (2) CGESM Interconnect Kit |
||
|
|
||
| HP BladeSystem p-Class Power Options | NOTE:
Use p-Class sizing tool to help determine power configuration: http://h30099.www3.hp.com/configurator/powercalcs.asp |
|
| Single Phase Power
Enclosure with 4 power supplies (NA/JPN) (Single Phase Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit) |
239162-001
|
|
| Single Phase Power
Enclosure with 4 power supplies (Int'l) (Single Phase Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit) |
239162-421
|
|
| 3 Phase Power Enclosure
with 6 power supplies (NA/JPN) (3 Phase Power Enclosure holds a maximum of 6 power supplies; no need to order additional power supplies with this option kit) |
230769-001
|
|
| 3 Phase Power Enclosure
with 6 power supplies (Int'l) (3 Phase Power Enclosure holds a maximum of 6 power supplies; no need to order additional power supplies with this option kit) |
230769-421
|
|
| Single Phase Power
Enclosure (empty) (NA/JPN) (Holds up to 4 power supplies; power supplies are not included in this kit) |
231710-001
|
|
| Single Phase Power
Enclosure (empty) (Int'l) (Holds up to 4 power supplies; power supplies are not included in this kit) |
231710-421
|
|
| 3 Phase Power Enclosure
(empty) (NA/JPN) (Holds up to 6 power supplies; power supplies are not included in this kit) |
231709-001
|
|
| 3 Phase Power Enclosure
(empty) (Int'l) (Holds up to 6 power supplies; power supplies are not included in this kit) |
231709-421
|
|
| Single Power Supply |
239161-B21
|
|
| 1U Power Enclosure
with six power supplies |
378284-B21
|
|
| 1U Power Enclosure
with two power supplies |
380314-B21
|
|
| Single 1U power supply |
380312-B21
|
|
| Facility DC Power Connection |
240563-B21
|
|
|
|
||
| HP BladeSystem p-Class Power Distribution (only required with 3U power enclosures) | HP BladeSystem p-Class Scalable Bus Bar |
240560-B21
|
| HP BladeSystem p-Class Mini Bus Bar |
240559-B21
|
|
| Dual Power Input Kit for Mini Bus Bar |
364565-B21
|
|
| HP BladeSystem p-Class Power Bus Box |
240562-B21
|
|
| HP Modular Distribution Unit 40
Amp (NA/JPN) |
252663-D75
|
|
| HP Modular Distribution Unit 40
Amp (Int'l) |
252663-B34
|
|
| HP Modular Distribution Unit 32
Amp (Int'l) |
252663-B33
|
|
| HP Modular Distribution Unit 24
Amp (NA/JPN) |
252663-D74
|
|
| NOTE: The Modular
Distribution Unit Kits excludes the extension bars as they are not required
with the HP BladeSystem p-class 1U power enclosure. |
||
| HP BladeSystem Power Extension
Kit NOTE: This kit is specifically for HP BladeSystem p-Class customers who want to upgrade their standard server blade enclosures to enhanced server blade enclosures and would like to install an additional, redundant 3U power enclosure above the server blade enclosures rather than below them. The option kit consists of two extension cable assemblies - one for each side (A and B). |
381686-B21
|
|
|
|
||
| SAN Switches | HP McDATA 4Gb SAN Switch |
A8001A
|
| Brocade 4GB SAN Switch, Base |
A7533A
|
|
| Brocade 4GB SAN Switch, full fabric |
A7534A
|
|
| Brocade 4GB SAN Switch, power pack |
A7535A
|
|
|
|
||
| HP BladeSystem p-Class Other Options | HP BladeSystem p-Class Diagnostic Station |
230743-B21
|
| HP BladeSystem p-Class Server
Enclosure Shipping Bracket Option Kit NOTE: Used to secure one server blade enclosure in a rack when moving. |
293121-B21
|
|
| HP BladeSystem p-Class Power Enclosure
Shipping Bracket Option Kit NOTE: Used to secure one power enclosure in a rack when moving. |
365044-B21
|
|
| HP BladeSystem p-Class Bus Bar Telco Rack Kit |
245249-B21
|
|
| HP BladeSystem p-Class Enclosure Telco Rack Kit |
266076-B21
|
|
|
|
||
|
Tape Libraries |
HP StorageWorks MSL6000
Tape Library |
|
| Ultrium 960 technology |
||
| MSL6030, 1 drive, 30 slots, Ultrium
960 |
AD606A | |
| MSL6030, 2 drive, 30 slots, Ultrium
960 |
AD607A | |
| MSL6030, 1 drive, 30 slots, Ultrium
960, with embedded FC router |
AD608A | |
| MSL6030, 2 drive, 30 slots, Ultrium
960, with embedded FC router |
AD609A | |
| MSL6060, 2 drive, 60 slots, Ultrium
960 |
AD610A | |
| MSL6060, 2 drive, 60 slots, Ultrium
960, with embedded FC router |
AD611A | |
| SDLT 600 technology |
||
| MSL6026, 1 drive, 26 slots, SDLT
600 |
AD582A | |
| MSL6026, 2 drive, 26 slots, SDLT
600 |
AD583A | |
| MSL6026, 1 drive, 26 slots, SDLT
600, with embedded FC router |
AD584A | |
| MSL6026, 2 drive, 26 slots, SDLT
600, with embedded FC router |
AD585A | |
| MSL6052, 2 drive, 52 slots, SDLT
600 |
AD587A | |
| MSL6052, 2 drive, 52 slots, SDLT
600, with embedded FC router |
AD588A | |
| Ultrium 460 technology |
||
| MSL6030, 1 drive, 30 slots, Ultrium
460 |
AD598A | |
| MSL6030, 2 drive, 30 slots, Ultrium
460 |
AD599A | |
| MSL6030, 1 drive, 30 slots, Ultrium
460, with embedded FC router |
AD600A | |
| MSL6030, 2 drive, 30 slots, Ultrium
460, with embedded FC router |
AD601A | |
| MSL6060, 2 drive, 60 slot Ultrium
460 |
AD603A | |
| MSL6060, 2 drive, 60 slot Ultrium 460, with embedded FC router | AD604A | |
| NOTE: Please reference the MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs | ||
| HP StorageWorks MSL5026S2 Tape Library | ||
| MSL5026S2, 1 drive, 26 slots, SDLT 320, RM |
293472-B22
|
|
| MSL5026S2, 2 drive, 26 slots, SDLT 320, RM |
293472-B23
|
|
| MSL5026S2, 1 drive, 26 slots, SDLT 320, RM with embedded FC router |
293472-B24
|
|
| MSL5026S2, 2 drive, 26 slots, SDLT 320, RM with embedded FC router |
293472-B25
|
|
| NOTE: Please reference the MSL5026S2 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs | ||
| HP StorageWorks MSL5052S2 Tape Library | ||
| MSL5052S2, 2 drive, 52 slots, SDLT 320, RM | 293474-B21 | |
| MSL5052S2, 2 drive, 52 slots, SDLT 320, RM with embedded FC router | 293474-B24 | |
| NOTE: Please reference the MSL5052S2 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http:/www.hp.com/go/ebs | ||
| HP StorageWorks MSL5060 Tape Library | ||
| MSL5060, 2 drive, 60 slots, Ultrium 230, RM | 301899-B23 | |
| MSL5060, 2 drive, 60 slots, Ultrium 230, RM with embedded FC router | 301900-B21 | |
| NOTE: Please reference the MSL5060 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs | ||
| HP StorageWorks ESL E-Series
Tape Libraries |
||
| ESL Extended 712e Tape Library,
0 drive, 712 LTO slots |
AA934B | |
| ESL Extended 630e Tape Library,
0 drive, 630 SDLT slots |
AA935B | |
| ESL Extended 322e Tape Library,
0 drive, 322 LTO slots |
AA939B | |
| ESL Extended 286e Tape Library,
0 drive, 286 SDLT slots |
AA940B | |
| ESL E-Series Ultrium 960 drive kit | AD595A | |
| ESL E Ultrium 460 drive kit |
AA937A | |
| ESL E-Series Ultrium 460-FC drive kit | AA941A | |
| ESL E SDLT 320 drive kit |
AA936A | |
| ESL E e2400-FC 2G Interface Controller |
AA928A | |
| NOTE: Please reference the ESL E-Series Tape Libraries QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution. Reference current compatibility information at http://www.hp.com/go/ebs | ||
| HP StorageWorks EML E-Series
Tape Libraries |
||
| EML103e Tape Library, 0 drive,
103 LTO slots |
AD560A | |
| EML 245e Tape Library, 0 drive,
245 LTO slots |
AD561A | |
| NOTE:
Please reference the EML E-Series Tape Libraries QuickSpecs at http://www.hp.com/go/automation
for additional information needed to create a complete solution. Reference
current compatibility information at http://www.hp.com/go/ebs |
||
| HP StorageWorks Virtual Library
Systems |
||
| HP 6105 Virtual Library System | AD728A | |
| HP 6510 Virtual Library System |
AD729A | |
| NOTE: Please reference the Virtual Library Systems Tape Libraries QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution. Reference current compatibility information at http://www.hp.com/go/ebs | ||
|
|
||
|
Magneto-Optical Jukeboxes |
HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes | |
| 300mx, 2 drive, 32 slot jukebox | C1150M | |
| 600mx, 4 drive, 64 slot jukebox | C1160M | |
| 700mx, 2 drive, 76 slot jukebox | C1170M | |
| NOTE: Please reference the Magneto-Optical Jukebox data sheets at http://www.hp.com/go/optical for additional information needed to create a complete solution | ||
| HP StorageWorks 9.1 GB High-end Optical Jukeboxes | ||
| 1200mx, 4 drive, up to 128 slots | C1104M | |
| 1200mx, 6 drive, up to 128 slots | C1105M | |
| 2200mx, 4 drive, up to 238 slots | C1111M | |
| 2200mx, 6 drive, up to 238 slots | C1107M | |
| 2200mx, 10 drive, up to 238 slots | C1110M | |
| NOTE: Please see the HP StorageWorks
Magneto-Optical Products data sheet for a complete listing of available
jukeboxes at: http://www.hp.com/products1/storage/products/archivalprod/ brochures/MO_family_pb.pdf NOTE: Please reference the Magneto-Optical Jukebox data sheets at http://www.hp.com/go/optical for additional information needed to create a complete solution |
||
| HP StorageWorks Ultra Density Optical Storage | ||
| 1000ux, 2 drive, 32 slot jukebox | AA965A | |
| 1900ux, 4 drive, 64 slot jukebox | AA966A | |
| 1900ux, 4 mixed drive, 64 slot jukebox | AA968A | |
| 2300ux, 2 drive, 76 slot jukebox | AA967A | |
| 3800ux, 4 drive, 128 slot jukebox | AA969A | |
| 3800ux, 6 drive, 128 slot jukebox | AA970A | |
| 7100ux, 4 drive, 238 slot jukebox | AA973A | |
| 7100ux, 6 drive, 238 slot jukebox | AA971A | |
| 7100ux, 10 drive, 238 slot jukebox | AA972A | |
| 7100ux, 6 mixed drive, 238 slot jukebox | AA974A | |
| NOTE:
Please see the HP StorageWorks Ultra Density Optical Jukeboxes QuickSpecs
for a complete listing of available jukeboxes at: http://h18006.www1.hp.com/products/quickspecs/11944_div/11944_div.html |
||
| NOTE: Please reference the Ultra Density Optical Jukebox QuickSpecs at http://www.hp.com/go/optical for additional information needed to create a complete solution | ||
|
|
||
| HP StorageWorks Modular Smart Array 1000 | HP StorageWorks Modular Smart Array 1000 |
201723-B22 |
| Modular Smart Array 1000 Controller |
218231-B22
|
|
| Modular Smart Array Fibre Channel I/O Module |
218960-B21
|
|
| Modular Smart Array hub 2/3 |
286763-B21
|
|
| HP StorageWorks Modular Smart Array 1000 |
201723-B22
|
|
| NOTE: Please see
the StorageWorks Modular Smart Array 1000 QuickSpecs for additional options
and configuration information at: http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.html (Worldwide) |
||
|
|
||
| Cluster Options | ProLiant Cluster Kit with OpenView Storage Mirroring |
364025-B21 |
| ProLiant Cluster HA/F200 for the Entry Level SAN |
364026-B21
|
|
| ProLiant Cluster HA/F200 for the Entry Level SAN |
364026-291 |
|
| NOTE:
For additional information regarding the ProLiant Cluster for HA/F100,
HA/F200 for Modular Smart Array 1000 please see the following QuickSpecs
at: http://h18000.www1.hp.com/products/quickspecs/11035_na/11035_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11035_div/11035_div.html (Worldwide) |
||
| ProLiant Cluster Starter kit |
364023-B21
|
|
| NOTE: For additional
information regarding the HP ProLiant Cluster for ProLiant Cluster HA/F500
for Enterprise Virtual Array please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11055_na/11055_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/11055_div/11055_div.html (Worldwide) |
||
| NOTE:
For additional information regarding the HP ProLiant Cluster for HA/F500
please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/10232_na/10232_na.html (North America) http://h18000.www1.hp.com/products/quickspecs/10232_div/10232_div.html (Worldwide) |
||
|
|
||
| USB Options | USB 1.44-MB External Diskette Drive (Carbonite) |
DC141B
|
| USB Optical Scroll Mouse (Carbonite) | DD441B | |
| 256MB HP Drive Key II (USB 2.0) | PH657A | |
|
|
||
| HP Rack 5000 Series (Graphite Metallic) |
HP 5642 Rack - Unassembled |
358254-B21
|
|
|
||
| Rack Options for Rack 5000 Series (Graphite Metallic) |
Stabilizer kit for 5642 Rack (Graphite
Carbon) NOTE: The stabilizing kit is used to prevent rack from tipping over |
374493-B21
|
| Baying Kit for 5642 Rack (Graphite
Carbon) NOTE: The baying kit is used to join two or more HP5642 racks. |
374499-B21
|
|
|
|
||
|
Rack 10000 Series |
Rack, HP Infrastructure 42U (HV) |
379005-001
|
| Rack, HP Infrastructure 42U (LV) |
379006-001
|
|
| HP Rack 10842 (42U) - Pallet NOTE: Server Blade Enclosures must be field integrated into the 10842 racks. Factory integration of Server Blade Enclosures into the 10842 is not supported. |
257415-B21
|
|
| HP Rack 10842 (42U) - Shock Pallet NOTE: Server Blade Enclosures must be field integrated into the 10842 racks. Factory integration of Server Blade Enclosures into the 10842 is not supported. |
257415-B22
|
|
| HP S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22
|
|
|
HP Rack 10647 (47U) Cabinet - Pallet |
245160-B21 |
|
|
HP Rack 10647 (47U) Cabinet - Crated |
245160-B23 |
|
|
HP Rack 10642 (42U) Cabinet - Pallet |
245161-B21 |
|
|
HP Rack 10642 (42U) Cabinet - Shock Pallet |
245161-B22 |
|
|
HP Rack 10642 (42U) Cabinet - Crated |
245161-B23 |
|
|
HP Rack 10636 (36U) Cabinet - Pallet |
245162-B21 |
|
|
HP Rack 10636 (36U) Cabinet - Shock Pallet |
245162-B22 |
|
|
HP Rack 10636 (36U) Cabinet - Crate |
245162-B23 |
|
|
HP Rack 10622 (22U) Cabinet - Pallet |
245163-B21 |
|
|
HP Rack 10622 (22U) Cabinet - Shock Pallet |
245163-B22 |
|
|
HP Rack 10622 (22U) Cabinet - Crated |
245163-B23 |
|
| NOTE: -B21 (pallet)
used to ship empty racks shipped on a truck -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels) -B23 (crated) used for air shipments of empty racks Not all HP equipment is qualified to be shipped in the Rack 10000 series. |
||
| NOTE: Please see
the Rack 10000 QuickSpecs for Technical Specifications such as height, width,
depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.html (Worldwide) http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html (North America) |
||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html | ||
|
|
||
|
Rack Options for HP Rack 10000 Series |
HP Rack Plinth Kit (Carbon) |
251960-B21
|
|||||||||||||||||||||||||||
| HP Rack Light Kit (Neon) |
361589-B21
|
||||||||||||||||||||||||||||
|
42U Side Panel – Graphite Metallic |
246099-B21 |
||||||||||||||||||||||||||||
|
36U Side Panel – Graphite Metallic |
246102-B21 |
||||||||||||||||||||||||||||
|
47U Side Panel – Graphite Metallic |
255486-B21 |
||||||||||||||||||||||||||||
| NOTE: For additional information regarding Rack Options, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. | |||||||||||||||||||||||||||||
|
TFT7210R Rack Mounted 17" Monitor |
348373-B21 |
||||||||||||||||||||||||||||
| TFT5600 Rack Keyboard Monitor |
221546-xx1
|
||||||||||||||||||||||||||||
| 1U Rack Keyboard & Drawer (Carbon) |
257054-xx1
|
||||||||||||||||||||||||||||
| Country Code Key (for TFT5600
RKM Rack Keyboard Monitor (PN 221546-xx1)and 1U Rack Keyboard & Drawer (Carbon)(P/N 257-54-xx1)) |
|||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
| NOTE: For additional information regarding Rack Options, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html | |||||||||||||||||||||||||||||
| NOTE: For a complete
list of Monitors please view the following URL: http://h18004.www1.hp.com/products/monitors/ |
|||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||
| HP KVM Switch Options | IP Console Switch Box (KVM/IP), 1 x 1 x 16 |
262585-B21
|
| IP Console Switch Box (KVM/IP), 3 x 1 x 16 |
262586-B21
|
|
| Serial Interface adapter - 1
Pack with power supply |
373035-B21
|
|
| Interface adapter - USB 1.0 (single pack) |
336047-B21
|
|
| CAT5e Cable 3', 4 pack |
263474-B21
|
|
| CAT5e Cable 6', 8 pack |
263474-B22
|
|
| CAT5e Cable 12', 8 pack |
263474-B23
|
|
| CAT5e Cable 20', 4 pack |
263474-B24
|
|
| CAT5e Cable 40', 1 pack |
263474-B25
|
|
| NOTE: For additional
information regarding HP KVM Switches and options, please see the following
URL: http://h18004.www1.hp.com/products/servers/proliantstorage/rack-options/list.html#console |
||
|
|
||
| Service and Support Offerings (HP Care Pack Services) |
| ||||||||||||||||||||||||||||||||||
|
|
|
Memory
|
HP ProLiant BL30p Server Blade (all models) |
|
Standard Memory |
|
Memory |
Slot |
||
|
1
|
2
|
||
|
Standard |
1024 MB |
1024 MB
|
|
| Optional |
1024 MB |
512 KB
|
512 KB
|
| Optional |
2048 MB
|
1024 MB
|
1024 MB
|
| Maximum |
4096 MB
|
2048 MB
|
2048 MB
|
|
Following are memory options available from HP: |
|
|
300682-B21 |
|
300680-B21 |
|
301044-B21 |
|
287497-B21 |
|
257974-B21 |
|
|
Technical Specifications
| HP BladeSystem p-Class Enhanced Server Blade Enclosure |
Dimensions |
Height |
10.5 in (26.67 cm) |
|
| Width |
17.60 in (44.70 cm) |
|||
| Depth |
28.86 in (73.30 cm) |
|||
|
Input Specifications |
Rated input voltage |
-43 VDC to -53 VDC |
Nominal -48 VDC | |
| Rated input current | 125 A at -48 VDC | |||
|
Rated input Power |
6000 W |
|||
|
Individual Server Blade |
Rated input voltage | -43 VDC to -53 VDC | Nominal -48 VDC | |
| Rated input current | 14.6 A at -48 VDC | |||
| Rated input Power | 700 W | |||
|
Temperature Range |
Operating | 50° to 95° F (10° to 35° C) | ||
| Non-Operating | -22° to 140° F (-30° to 60° C) | |||
|
Relative Humidity |
Operating | 20% to 80% | ||
| Non-Operating | 5% to 95% | |||
|
Wet Bulb Temperature |
Operating | 82.4° F (28° C) | ||
| Non-Operating | 101.7° F (38.7° C) | |||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | ||||
|
|
||||
| Operating and Performance Specifications for ProLiant BLp-Class RJ-45 Patch Panel 2 with Fiber Channel pass through |
Dimensions | Height |
10.405 in (26.43 cm) |
| Width |
1.535 in (3.899 cm) | ||
| Depth | 27.697 in (70.35 cm) | ||
| Capability | IEEE 802.2, 802.3, 802.3u | ||
|
Network Transfer Rate |
10 Base-T (half-duplex) |
10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (full-duplex) | 1000 Mbps | ||
| Fiber Channel SAN | Velio VC1070 re-timer | Auto-rate negotiate between 2G and 1G | |
|
Connector | Network | 32 RJ-45 in the back. | |
| Fiber Channel SAN | 16 Pluggable SFP optical cages in the front | ||
|
Cable Support | 10 Base-TX | Categories
3, 4, or 5 UTP (2 or 4 pair); up to 328 ft (100 m) | |
| 100 Base-TX | Category 5 UTP (2 pair); up to 328 ft/100 m | ||
| 1000 Base-TX | Category 5E (4 pair); up to 328 ft (100 m) | ||
| Fiber Channel | SFP optical cable | ||
| EMI | FCC Class A | ||
| ICES-003 Class A | |||
| AS/NZS 3548 Class A | |||
| VCCI Class A | |||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
| | |||
| Operating and Performance Specifications for ProLiant BL p-Class RJ-45 Patch Panel |
Dimensions | Height |
10.405 in (26.43 cm) |
| Width |
1.535 in (3.899 cm) | ||
| Depth | 27.697 in (70.35 cm) | ||
| Capability | IEEE 802.2, 802.3, 802.3u | ||
|
Network Transfer Rate |
10 Base-T (half-duplex) |
10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (full-duplex) | 1000 Mbps | ||
| Connector |
Network | 16 RJ-45 in the back | |
| Cable Support | 10 Base-TX | Categories 3, 4, or 5 UTP
(2 or 4 pair); up to 328 ft (100 m) | |
| 100 Base-TX | Category 5 UTP (2 pair); up to 328 ft (100 m) | ||
| 1000 Base-TX | Category 5E (4 pair); up to 328 ft (100 m) | ||
|
Power Requirements | 200 mA at + 5V DC; 500 mA at -48V | ||
| Temperature Range | Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative
Humidity (non-condensing) | Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature | Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
| | |||
| Operating and Performance Specifications for ProLiant BL p-Class GbE Interconnect Switch |
Dimensions |
Height |
10.405 in (26.43 cm) |
| Width |
1.535 in (3.899 cm) |
||
| Depth |
27.697 in (70.35 cm) |
||
| Weight | 11.5 lb/5.2 kg per interconnect switch | ||
|
Performance |
9.6 Gbps external port bandwidth per server blade enclosure (full duplex) | ||
| Forwarding rate 0.15 million pps per 10/100 port, 1.5 million pps per gigabit port, (64-byte packets) | |||
| Non-blocking, full-wire speed for all connections | |||
| Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support | |||
|
Forwarding Mode |
Store and forward | ||
| MAC Addresses | 8,191 per interconnect switch; MAC address based filtering and MAC address packet priority configuring | ||
| Forwarding Table Age Time |
Maximum age: 1 to 1,000,000 seconds; default: 300 seconds | ||
| Memory | 32MB Main, 6MB flash and 16MB packet buffer per interconnect switch | ||
| Compliance | IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE only), 802.1D, 802.1p, 802.3ac, 802.3ad (Static), and 802.1Q | ||
| SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9 | |||
| MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB (RFC 2674), Entity MIB (RFC 2037), SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757), and HP Enterprise Switch MIBs and Environmental Traps | |||
| IGMP v1 (RFC 1112), IGMP v2 (RFC 2236), SNTP (RFC 1361), Telnet (RFC 854), TFTP client (RFC 783), BootP client, (RFC 2132), DHCP client, (RFC 2131) and ZModem, | |||
| Network Transfer Rate |
10 Base-T (half-duplex) | 10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (half and full-duplex) | 2000 Mbps | ||
| 1000 Base-SX (full-duplex) | 2000 Mbps | ||
| Connector | 12 RJ-45, 2 DB-9 (C-GbE
Interconnect Kit) 4 LC fiber, 8 RJ-45, 2 DB-9 (F-GbE Interconnect Kit) |
||
| EMI | FCC Class A | ||
| ICES-003 Class A | |||
| AS/NZS 3548 Class A | |||
| VCCI Class A | |||
| Safety | UL/CUL Listed Accessory | ||
| CE | |||
| Power Requirements |
-48VDC: 1050 mA, 50 W maximum (per interconnect switch) | ||
| Temperature R range |
Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative Humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature |
Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
|
|
|||
| Operating and Performance Specifications for ProLiant BL p-Class GbE2 Interconnect Switch |
Dimensions |
Height |
10.405 in (26.43 cm) |
| Width |
1.535 in (3.899 cm) |
||
| Depth |
27.697 in (70.35 cm) |
||
| Weight | 12.0 lb/5.4 kg per interconnect switch | ||
|
Performance |
24 Gbps External port bandwidth per server blade enclosure (full duplex) | ||
| Forwarding rate 1.5 million pps per gigabit port (64-byte packets) | |||
| Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support | |||
|
Forwarding Mode |
Store and forward | ||
| MAC Addresses | 2,048 per interconnect switch | ||
| Forwarding Table Age Time |
Maximum age: 1 to 65535 seconds; default: 300 seconds | ||
| Memory | 128MB Main, 32MB flash and 2MB packet buffer per interconnect switch | ||
| Compliance | IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE2 only), 802.1D, 802.3ac, 802.3ad (Static), and 802.1Q | ||
| SNMP v1 (RFC 1157), MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB , Entity MIB (RFC 2037), RADIUS Authentication MIB, 802.3-2002 MIB, SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757) and HP Enterprise Switch MIBs and Environmental Traps | |||
| RADIUS (RFC 2138), Telnet (RFC 854), TFTP client (RFC 783), SSH v1.5, SCP v1.5, NTP v2 (RFC 1119), BootP client (RFC 2132), and XModem | |||
| Network Transfer Rate |
10 Base-T (half-duplex) | 10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (half and full-duplex) | 2000 Mbps | ||
| 1000 Base-SX (full-duplex) | 2000 Mbps | ||
| Connector | 12 RJ-45, 2 DB-9 (C-GbE2
Interconnect Kit) 8 LC fiber, 4 RJ-45, 2 DB-9 (F-GbE2 Interconnect Kit) |
||
| EMI | FCC Class A | ||
| ICES-003 Class A | |||
| AS/NZS 3548 Class A | |||
| VCCI Class A | |||
| Safety | UL/CUL Listed Accessory | ||
| CE | |||
| Power Requirements |
48VDC: 2040 mA, 98 W
maximum (per interconnect switch without Storage Connectivity Kit) 48VDC: 2355 mA, 113 W maximum (per interconnect switch with Storage Connectivity Kit) |
||
| Temperature Range |
Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative Humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature |
Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa. | |||
|
|
|||
| Operating and Performance Specifications for CGESM Interconnect Switch |
Dimensions | Height | 10.405 in (26.43 cm) |
| Width | 1.6 in (4.06 cm) | ||
| Depth | 28 in (71.12 cm) | ||
| Weight | 11.5 lb/5.2 kg per interconnect switch | ||
| Performance | 28 Gbps Maximum Forwarding Bandwidth. 38.7mpps Maximum Forwarding Rate (64 Byte Packets) | ||
| 9018Bytes Jumbo Frames MTU | |||
| Non-blocking architecture. Wire Speed Performance on all ports | |||
| Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support | |||
| Forwarding Mode | Store and forward | ||
| MAC Addresses | 8000 MAC/physical address Table Size | ||
| Memory | 128MB DRAM Memory. 16MB Flash Memory | ||
| Compliance | IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3ad, IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and, IEEE 802.1D Spanning-Tree Protocol, IEEE 802.1p CoS Prioritization, IEEE 802.1Q VLAN, IEEE 802.3 10BASE-T specification, IEEE 802.3u 100BASE-TX specification, IEEE 802.3ab 1000BASE-T specification, IEEE 802.3z 1000BASE-X specification, RMON I and II standards, SNMPv1, SNMPv2c, and SNMPv3 (RFC1493) , CISCO-CDP-MIB, CISCO-CLUSTER-MIB, CISCO-CONFIG-MAN-MIB, CISCO-ENTITY-FRU-CONTROL-MIB, CISCO-ENVMON-MIB, CISCO-FLASH-MIB, CISCO-FTP-CLIENT-MIB, CISCO-IGMP-FILTER-MIB, CISCO-IMAGE-MIB, CISCO IP-STAT-MIB, CISCO-MAC-NOTIFICATION-MIB, CISCO-MEMORY-POOL-MIB, CISCO-PAGP-MIB, CISCO-PING-MIB, CISCO-PROCESS-MIB, CISCO-RTTMON-MIB, CISCO-STP-EXTENSIONS-MIB, CISCO-SYSLOG-MIB, CISCO-TCP-MIB, CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB, CISCO-VLAN-MEMBERSHIP-MIB, CISCO-VTP-MIB, ENTITY-MIB, ETHERLIKE-MIB, IF-MIB (in and out counters for VLANs are not supported), IGMP-MIB, OLD-CISCO-CHASSIS-MIB, OLD-CISCO-FLASH-MIB, OLD-CISCO-INTERFACES-MIB, OLD-CISCO-IP-MIB, OLD-CISCO-SYS-MIB, OLD-CISCO-TCP-MIB, OLD-CISCO-TS-MIB, RFC1213-MIB (per the agent capabilities specified in the, CISCO-RFC1213-CAPABILITY.my), RFC1253-MIB, RMON-MIB, RMON2-MIB, SNMP-FRAMEWORK-MIB, SNMP-MPD-MIB, SNMP-NOTIFICATION-MIB, SNMP-TARGET-MIB, SNMPv2-MIB, TCP-MIB, UDP-MIB 1000BASE-T ports, 1000BASE-X (SFP), 1000BASE-SX | ||
| Network Transfer Rate |
10 Base-T (half-duplex) |
10 Mbps | |
| 10 Base-T (full-duplex) |
20 Mbps | ||
| 100 Base-TX (half-duplex) |
100 Mbps | ||
| 100 Base-TX (full-duplex) |
200 Mbps | ||
| 1000 Base-TX (half and full-duplex) |
2000 Mbps | ||
| 1000 Base-SX (full-duplex) | 2000 Mbps | ||
| Connector | 4 SFP, 2 RJ-45 10/100/1000 T/TX/T, 1 DB-9 | ||
| EMI | FCC Part 15 Class A | ||
| EN 55022: 1998 (CISPR22)
EN 55024: 1998 (CISPR24) CNS 13438 Class A MIC CD MIC |
|||
| AS/NZS 3548 Class A CE | |||
| VCCI Class A | |||
| Safety | UL to UL 60950, Third
Edition C-UL to CAN/CSA C22.2 No. 60950-00, Third Edition TUV/GS to EN 60950:2000 CB to IEC 60950 with all country deviations NOM to NOM-019-SCFI CE Marking |
||
| Power Requirements |
-48VDC: 1050 mA, 125 W maximum (per interconnect switch) | ||
| Temperature Range | Operating | 50 to 95º F (10 to 35º C) | |
| Non-operating | -22 to 140º F (-30 to 60º C) | ||
|
Relative Humidity |
Operating |
20% to 85% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature |
Operating |
82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
|
|
|||
| Operating and Performance
Specifications for 3U HP BladeSystem p-Class Power Enclosures (North America/Japan) | Single-Phase Model | 3-Phase Model | ||
| Dimensions | Height | 5.25 in (13.34 cm) | 5.25 in (13.34 cm) | |
| Width | 27.15 in (68.96 cm) | 27.15 in (68.96 cm) | ||
| Depth | 17.60 in (44.7 cm) | 17.60 in (44.7 cm) | ||
| Weights | No
Hot-Plug Power Supplies | 47.5 lb (21.55 kg) | 47.5 lb (21.55 kg) | |
| All Hot-Plug Power Supplies | 99.5 lb (45.13 kg) | 125.5 lb (56.93 kg) | ||
| Input Requirements | Rated input voltage | 200 VAC to 240 VAC | 200 VAC to 240 VAC line to line | |
| Rated input frequency | 50 Hz to 60 Hz | 50 Hz to 60 Hz | ||
| Rated input
current per side | 24A | 24A per phase | ||
| Rated input
power per side | 5760 W | 9976 W | ||
| Power cord | 1 NEMA L6-30P per side | 1 NEMA L15-30 per side | ||
| Output
Voltage Specifications | Rated output voltage | -48.8 VDC to -54 VDC | -48.8 VDC to -54 VDC | |
| Rated output current | 99A | 170A | ||
| Rated output power | 4298 W | 8310 W | ||
| Nominal power | 4158 W at 208 VAC | 7202 W at 208 VAC | ||
| Ambient
Temperature Range (See NOTE) |
Operating | 50°
to 95° F (10° to 35° C) | 50°
to 95° F (10° to 35° C) | |
| Shipping | -22°
to 140° F (-30° to 60° C) | -22°
to 140° F (-30° to 60° C) | ||
| Relative
humidity, non-condensing (See NOTE) | Operating | 20% to 80% | 20% to 80% | |
| Non-operating | 5% to 95% | 5% to 95% | ||
| Wet Bulb Temperature | Operating | 82.4° F (28° C) | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | ||||
| | ||||
| Operating and Performance
Specifications for 3U HP BladeSystem p-Class Power Enclosures (International) |
Single-Phase Model | 3-Phase Model | ||
| Dimensions | Height | 5.25 in (13.34 cm) | 5.25 in (13.34 cm) | |
| Width | 27.15 in (68.96 cm) | 27.15 in (68.96 cm) | ||
| Depth | 17.60 in (44.7 cm) | 17.60 in (44.7 cm) | ||
| Weights | No
Hot-Plug Power Supplies | 47.5 lb (21.55 kg) | 47.5 lb (21.55 kg) | |
| All Hot-Plug Power Supplies | 99.5 lb (45.13 kg) | 125.5 lb (56.93 kg) | ||
| Input Requirements | Rated input voltage | 200 VAC to 240 VAC | 6.25 A at -48 VDC 200 VAC to 240 VAC line to neutral | |
| Rated input frequency | 50 Hz to 60 Hz | 50 Hz to 60 Hz | ||
| Rated input
current per side | 24A | 20A per phase | ||
| Rated input
power per side | 5760 W | 10,552 W | ||
| Power cord | 1
IEC 309 3-pin, 32A per side | 1
IEC 309 5-pin, 32A per side | ||
| Output
Voltage Specifications | Rated output voltage | -48.8 VDC to -54 VDC | -48.8 VDC to -54 VDC | |
| Rated output current | 99A | 180A | ||
| Rated output power | 4798 W | 8790 W | ||
| Nominal power | 4598 W at 208 VAC | 8790 W at 230 VAC L-N | ||
| Ambient
Temperature Range (See NOTE) |
Operating | 50°
to 95° F (10° to 35° C) | 50°
to 95° F (10° to 35° C) | |
| Shipping | -22°
to 140° F (-30° to 60° C) | -22°
to 140° F (-30° to 60° C) | ||
| Relative
humidity, non-condensing (See NOTE) | Operating | 20% to 80% | 20% to 80% | |
| Non-operating | 5% to 95% | 5% to 95% | ||
| Wet Bulb Temperature | Operating | 82.4° F (28° C) | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | ||||
| | ||||
| Operating and Performance Specifications for HP BladeSystem p-Class Power Distribution Devices | Power Bus Box | Mini Bus Bar | Scalable Bus Bar | |
| Power Enclosures or facility DC feeds Supported (3U each) |
1
|
1 or 2
|
1 or 2
|
|
| Server blade enclosures supported (6U each) |
1
|
up to 3
|
up to 5
|
|
| Total rack height of supported enclosures |
9U
|
24U
|
36U
|
|
| Dimensions | ||||
| Height | 5.1 in (12.95 cm) | 19.45 in (49.40 cm) | 48.57 in (123.37 cm) | |
| Width | 3.6 in (9.14 cm) each | 19.74 in (50.14 cm) | 19.74 in (50.14 cm) | |
| Depth | 3.25 in (8.26 cm) | 2.2 in (5.59 cm) | 2.2 in (5.59 cm) | |
|
Weight |
3.62 lb (1.64 kg) | 13.2 lb (5.9 kg) | 26 lb (11.79 kg) | |
| Rated Operating Voltage |
-43.2 VDC to -54 VDC | -43.2 VDC to -54 VDC | -43.2 VDC to -54 VDC | |
| Max Total Power Supported |
3000 W | 9000 W | 15000 W | |
| Total Max Input Current At Minimum Voltage |
69.44 A at -43.2VDC | 208.32 A at -43.2 VDC | 347.2 A at -43.2 VDC (equivalent of 175A per feed) |
|
| Total Max Input Current At Nominal Voltage |
62.5 A at -48VDC | 187.5 A at -48 VDC | 312.5 A at -48 VDC (equivalent of 175A per feed) |
|
| Max Current Per Power Feed |
70A | 70A | 210A | |
| Max Local Ambient Temperature |
149° F (65° C) | 149° F (65° C) | 149° F (65° C) | |
| NOTE: All systems support redundant A & B feeds. Scalable bus bar supports dual A and dual B feeds. | ||||
|
|
||||
|
Operating and Performance Specifications for Facility DC |
Voltage |
Nominal input voltage |
-48 VDC |
| Operating voltage range |
-48VDC ± 10% or -43.2 VDC to -52.8 VDC |
||
| Max Input voltage slew rate | 0.5V/uS | ||
| Redundant feed voltages* (A & B) |
*A and B feeds must differ by no more than 5VDC during steady state operation | ||
| Ripple/Noise | 480 mV PARD** | ||
| Overshoot | Must remain within regulation limits on all feeds during startup or shutdown | ||
| Voltage transients |
Must not exceed -60 VDC |
||
|
Current |
Max steady state input current | 62.5A per server blade enclosure installed at -48VDC | |
| Max steady state current per feed/total | |||
|
70 A/70A | ||
|
210 A/210A | ||
|
210 A/350A or equivalent of 175A per feed* | ||
| In-rush current | Must support up to 2X the maximum operating current per server blade enclosure (125 A) for up to 1.0 mS | ||
| Input over-current | Customer provided fusing for facility DC feeds that protects the system from catastrophic over-current within 20 uS. Fuse should sustain all in-rush and operating currents. | ||
| Max Input Current Slew Rate | 1A/uS | ||
| Max Rated Power | 3000W per server blade enclosure | ||
|
Connections and Cables |
HP provided facility DC cable connection kit: | ||
|
|||
| The power cable assemblies consist of 1/0AWG, color-coded, flexible cable rated at 105° C, terminated with bus mating connectors at one end and unterminated at the other end. The cable length provided enables the customer to route to a fuse panel within or adjacent to the rack. | |||
| NOTE: *All systems support redundant A and B feeds. Scalable bus bars support dual A and dual B feeds. | |||
| ** Periodic and random noise (PARD). Maximum allowable peak-to-peak ripple and noise (as measured at the load on any output channel). The ripple and noise is measured over a 20 Hz to 100 MHz frequency band. A resistive load (non-electronic) is used for this measurement. Each output is by-passed to return by a 10uF tantalum capacitor with an ESR less than 100 milli-Ohms in parallel with a 0.47 uF ceramic capacitor, at the point of load. The load cable is 12 feet of twisted wire capable of carrying the current. The printed wiring board assembly is installed in its enclosure for this measurement, or the measurement leads are properly shielded with Earth grounds applied to the insert. | |||
|
|
|||
|
© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |