Overview
|
HP ProLiant ML150 Generation 2 (G2)
|
||||||||||||||
| What's New |
|
|
|
| At A Glance |
|
|
|
Standard Features
| Processor NOTE: One of the following depending on Model |
Intel Xeon Processor 3.2 GHz/800 -1MB L2 |
| Intel Xeon Processor 3.0 GHz/800 -1MB L2 | |
| Intel Xeon Processor 2.8 GHz/800 -1MB L2 | |
| Intel Xeon Processor 3.2 GHz/800 -2MB L2 | |
| Intel Xeon Processor 3.0 GHz/800 -2MB L2 | |
| Intel Xeon Processor 2.8 GHz/800 -2MB L2 | |
|
|
|
| Cache Memory | Integrated 1MB or 2MB level
2 cache (Depending on model) |
|
|
|
| Upgradeability | Upgradeable to dual processing |
|
|
|
| Chipset | Intel® E7320 Chipset with 800MHz Front Side Bus |
|
|
|
| Memory | Type | PC2700 DDR SDRAM (333MHz) |
| Standard | 512 MB | |
| Maximum | 8 GB | |
|
|
||
| Network Controller |
Broadcom 5721 PCI-Express Gigabit NIC (embedded) 10/100/1000 WOL (Wake on LAN) |
|
|
|
| Expansion Slots | I/O (6 Total, 5 Available) | PCI Voltage: | |
| 64-bit/66MHz PCI-X | 4 (3 available) | 3.3 volts | |
| x 4 PCI-Express | 1 | 3.3 volts | |
| 32-bit/33MHz PCI | 1 | 5 volts | |
|
|
|||
| Storage Controller
NOTE: One of the following depending on Model |
Single Channel Ultra320 SCSI Adapter in a PCI slot(SCSI Models) |
| 4 port SATA Adapter in a PCI slot (SATA Model) | |
|
|
|
| Storage | Diskette Drive | 1.44 MB Diskette Drive |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Hard Drives | 36-GB 15,000 rpm hard drive included in non-hot plug SCSI models only | |
|
|
||
| Maximum Internal Storage | SCSI Models | 880GB (6 x 146GB SCSI drives) |
| SATA Models | 3TB (6 X 500GB SATA drives)
with optional 6 Port SATA RAID Controller or 2TB (4 x 500GB SATA drives) with standard controller |
|
|
|
||
| Interfaces | Parallel | 1 |
| Serial | 1 | |
| Pointing Device (Mouse, PS2) | 1 | |
| Graphics | 1 | |
| Keyboard (PS2) | 1 | |
| USB 2.0 Ports Dedicated USB |
3 (2 Rear, and 1 Internal) NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html. |
|
| Network RJ-45 (Ethernet) | 1 | |
|
|
||
| Graphics | Integrated ATI RAGE XL Video Controller with 8 MB SDRAM Video Memory |
|
|
|
| Form Factor | Tower (5U) |
|
|
|
| Industry Standard Compliance | ACPI V1.0b compliant |
| PCI 2.2 compliant | |
| PXE Support | |
| WOL Support | |
| Microsoft® Logo certifications | |
| Novell Logo certifications | |
|
|
|
| Manageability | Optional HP ProLiant ML150 G2 Lights-Out 100 Remote Management Card |
|
|
|
| Security | Power-on password Setup password Diskette boot control |
|
|
|
| Server Power Cords | One Lowline NEMA power cord |
| NOTE: Tower models ship standard with a 6' lowline NEMA power cord. | |
|
|
|
| Power Supply | 600 Watts, non-hot plug, non-redundant |
|
|
|
| System Fans | 2 - Non-hot plug, Non-redundant system fans shipped standard |
|
|
|
| OS Support | Microsoft Windows® 2000
Server Microsoft Windows 2003 Server, Standard Edition (32 and 64 bit) Microsoft Windows 2003 Server, Web Edition Microsoft Small Business Server 2003 Novell NetWare 6.5 Novell NetWare SBS 6.5 Red Hat Enterprise Linux SUSE Linux Enterprise Server SCO Unixware 7.1.4 VMware Virtualization Software |
| NOTE: For an
up-to-date listing of the latest ML150 OS support matrix, please see: http://www.hp.com/go/supportos |
|
| NOTE: For an up-to-date listing of the latest drivers available for the HP server ML150, please see: http://h18023.www1.hp.com/support/files/server/us/index.html | |
| NOTE: For more
information on HP's Certified and Supported ProLiant Servers, please visit
the VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html NOTE: Drivers may also found on the base media for some Linux OS's. When configuring your server, please consult your base media driver base, or visit HP.com at: http://h18023.www1.hp.com/support/files/server/us/index.html NOTE: For more Linux OS support & certification information, please visit our the ProLiant & Bladesystem Server Linux matrix http://h18004.www1.hp.com/products/servers/linux/hpLinuxcert.html |
|
|
|
|
| Factory Express Portfolio for Servers and Storage | HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging and custom packaging to meet customer needs. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant & HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services on your specific server model please contact your sales representative or go http://www.hp.com/go/factory-express. |
|
|
|
| HP Enterprise Configurator |
The HP eCo-Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. |
|
|
|
| HP ProLiant Smart Buys |
The HP Smart Buy program offers mainstream business solutions at competitive
prices with excellent availability and superior HP quality. It offers
a wide range of industry-leading HP products at compelling prices, allowing
you to receive richer configurations with additional options. |
|
|
|
| Service and Support |
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of resellers and service providers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. NOTE: Limited warranty includes 1 year
parts, 1 year labor, 1-year on-site support (ROW) HP Care Pack services include coverage for the HP branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to 3kVA; these items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. HP services provide continuous care and support expertise with committed response designed to meet your IT and business needs. To fully capitalize on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime. Enhanced Care - Minimum recommended service support offer designed to ensure customers have access to expert assistance, whenever they need it.
Continuance Care - Recommended service, delivering cost-effective support options designed to extend HP Services committed response and guaranteed fix times, designed to speed problem identification and resolution.
Total Care - Highest HP Support service level recommend to help increase IT performance and availability with comprehensive, integrated hardware and software services
Deployment Services - HP Installation and Start Up services designed to take time, risk, and worry out of the deployment of ProLiant servers - and free customers IT support staff to focus on what they do best, their business.
For a complete listing of service offerings
and information visit: |
|
|
Models
| ML150T02
X3.2/800-2M HP-SATA 380188-001 | Processor | (1) Intel Xeon 3.2 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Memory | 512 MB (Standard) to 8 GB (Maximum) PC2700 DDR SDRAM (333MHz) | |
| Network Controller | Broadcom 5721 PCI-Express Gigabit NIC (embedded) 10/100/1000 WOL (Wake on LAN) | |
| Storage Controller | 4 port SATA Adapter in a PCI slot | |
| Hard Drive | None ship standard (up to 6 HDD supported with optional 6 Port SATA RAID Controller; up to 4 HDD supported with standard SATA controller) | |
| Internal Storage | 3TB (6 x 500GB SATA drives w/ optional 6 Port SATA RAID Controller) maximum | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Form Factor | Tower (5U) | |
| | ||
|
ML150T02 X3.0/800-1M HP-SCSI |
Processor | (1) Intel Xeon 3.0 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 1MB Level 2 cache | |
| Memory | 512 MB (Standard) to 8 GB (Maximum) PC2700 DDR SDRAM (333MHz) | |
| Network Controller | Broadcom 5721 PCI-Express Gigabit NIC (embedded) 10/100/1000 WOL (Wake on LAN) | |
| Storage Controller | Single Channel Ultra320 SCSI Adapter in a PCI slot | |
| Hard Drive | None ship standard (up to 6 supported) | |
| Internal Storage | 880GB maximum | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM drive | |
| Form Factor | Tower (5U) | |
|
|
||
|
ML150T02 X3.0/800-1M NHP-SCSI36
| Processor | (1) Intel Xeon 3.0 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 1MB Level 2 cache | |
| Memory | 512 MB (Standard) to 8 GB (Maximum) PC2700 DDR SDRAM (333MHz) | |
| Network Controller | Broadcom 5721 PCI-Express Gigabit NIC (embedded) 10/100/1000 WOL (Wake on LAN) | |
| Storage Controller | Single Channel Ultra320 SCSI Adapter in a PCI slot | |
| Hard Drive | (1) 36.4-GB Ultra320 SCSI 15,000 rpm Drive (up to 6 supported) | |
| Internal Storage | 880GB maximum | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Form Factor | Tower (5U) | |
| | ||
| ML150T02
X3.0/800-1M HP-SATA 366358-001 | Processor | (1) Intel Xeon 3.0 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 1MB Level 2 cache | |
| Memory | 512 MB (Standard) to 8 GB (Maximum) PC2700 DDR SDRAM (333MHz) | |
| Network Controller | Broadcom 5721 PCI-Express Gigabit NIC (embedded) 10/100/1000 WOL (Wake on LAN) | |
| Storage Controller | 4 port SATA Adapter in a PCI slot | |
| Hard Drive | None ship standard (up to 6 HDD supported with optional 6 Port SATA RAID Controller; up to 4 HDD supported with standard SATA controller) | |
| Internal Storage | 3TB (6 x 500GB SATA drives w/ optional 6 Port SATA RAID Controller) maximum | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM drive | |
| Form Factor | Tower (5U) | |
| | ||
| ML150T02
X2.8/800-1M HP-SATA 366357-001 | Processor | (1) Intel Xeon 2.8 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 1 MB Level 2 cache | |
| Memory | 512 MB (Standard) to 8 GB (Maximum) PC2700 DDR SDRAM (333MHz) | |
| Network Controller | Broadcom 5721 PCI-Express Gigabit NIC (embedded) 10/100/1000 WOL (Wake on LAN) | |
| Storage Controller | 4 port SATA Adapter in a PCI slot | |
| Hard Drive | None ship standard (up to 6 HDD supported with optional 6 Port SATA RAID Controller; up to 4 HDD supported with standard SATA controller) | |
| Internal Storage | 3TB (6 x 500GB SATA drives w/ optional 6 Port SATA RAID Controller) maximum | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Form Factor | Tower (5U) | |
| | ||
|
|
Configuration Information-Factory Integrated Models
| NOTE:
HP does not allow factory integration of options into standard models listed
above. Configure-to-order servers must start with a CTO Chassis. NOTE: This product offering does not support HP Factory Express Server Configuration Level 1. NOTE: FIO indicates that this option is a Factory Installable Option. |
||
| Step 1: Base Configuration (Select only one model from the following selections) | ||
| Models | HP ProLiant ML150 G2 Hot Plug SCSI Model |
377880-405
|
| HP ProLiant ML150 G2 Non-hot Plug SCSI Model |
377881-405
|
|
| HP ProLiant ML150 G2 Hot Plug SATA Model |
377882-405
|
|
| Factory Integrated Models ship
with: |
||
| Broadcom 5721 PCI-Express Gigabit
NIC (embedded) 10/100/1000 WOL (Wake on LAN) |
||
| 1.44MB Diskette Drive | ||
| Single 600W Power Supply | ||
| Tower 5U Form Factor | ||
|
|
||
| Step 2: Choose Required Options (Select only one option from each category unless otherwise noted) | ||
| Processors | For single processor configuration choose: | |
| X3.0/800-1M ML150G2 FIO NOTE: If 2 processors are desired, select one 371542-L21and one 371542-B21 |
371542-L21
|
|
| Base Memory | 512 MB Advanced ECC PC2700 DDR SDRAM DIMM Kit (1 x 512 MB) |
358347-B21
|
| 1 GB Advanced ECC PC2700 DDR SDRAM DIMM Kit (1 x 1024 MB) |
358348-B21
|
|
| 2 GB Advanced ECC PC2700 DDR SDRAM DIMM Kit (1 x 2048 MB) |
358349-B21
|
|
| Optical Drives | 48X CD-ROM Kit |
377998-B21
|
| CD-RW/DVD-ROM Combo Drive Option Kit |
331346-B21
|
|
| HP DVD±RW 16X Half Height CBT Drive ALL |
383974-B21
|
|
|
|
||
| Step 3: Choose Additional Factory Integratable Options | ||
| Base Hard Drives | SATA - Hot Plug HDD (SATA Models Only) | |
| HP 500GB 1.5G SATA 7.2K 3.5" HDD | 395473-B21 | |
| HP 250GB 1.5G SATA 7.2K 3.5" HDD | 349239-B21 | |
| HP 160GB 1.5G SATA 7.2K 3.5" HDD | 349238-B21 | |
| HP 80GB 1.5G SATA 7.2K 3.5" HDD | 349237-B21 | |
| Ultra320 SCSI - Hot Plug | ||
| HP 146GB U320 10K Universal HDD ML150G2 | 371535-B21 | |
| HP 72GB U320 10 K Universal HDD ML150G2 | 377537-B21 | |
| HP 36GB U320 15K Universal HDD ML150G2 | 371534-B21
| |
| Ultra320 SCSI - Non-hot Plug | ||
| HP 146GB U320 10K NHP HDD |
356990-B21 | |
| HP 72GB U320 10K NHP HDD | 332751-B21 | |
| HP 36GB U320 15K NHP HDD |
357012-B21 | |
|
|
Options
| NOTE: Some options may not be factory integratable. Please contact your local sales representative for additional information. | ||
| Processors | Intel Xeon 2.8 GHz /800MHz-1MB Processor Option Kit for ML150G2 |
371541-B21
|
| Intel Xeon 3.0 GHz /800MHz-1MB Processor Option Kit for ML150G2 |
371542-B21
|
|
| Intel Xeon 3.2 GHz /800MHz-1MB Processor Option Kit for ML150G2 |
371543-B21
|
|
|
|
||
| Memory | 512 MB Advanced ECC PC2700 DDR SDRAM DIMM Kit (1 x 512 MB) |
358347-B21
|
| 1 GB Advanced ECC PC2700 DDR SDRAM DIMM Kit (1 x 1024 MB) |
358348-B21
|
|
| 2 GB Advanced ECC PC2700 DDR SDRAM DIMM Kit (1 x 2048 MB) |
358349-B21
|
|
|
|
||
| Optical Drives | CD-RW/DVD-ROM Combo Drive Option Kit |
331346-B21
|
| HP DVD±RW 16X Half Height CBT Drive |
383974-B21
|
|
|
|
||
| Hard Drives | SATA - Hot Plug HDD (SATA Models Only) | |
| HP 500GB 1.5G SATA 7.2K 3.5" HDD | 395473-B21 | |
| HP 250GB 1.5G SATA 7.2K 3.5" HDD | 349239-B21 | |
| HP 160GB 1.5G SATA 7.2K 3.5" HDD | 349238-B21 | |
| HP 80GB 1.5G SATA 7.2K 3.5" HDD | 349237-B21 | |
| Ultra320 SCSI - Hot Plug | ||
| HP 146GB U320 10K Universal HDD ML150G2 | 371535-B21 | |
| HP 72GB U320 10 K Universal HDD ML150G2 | 377537-B21 | |
| HP 36GB U320 15K Universal HDD ML150G2 | 371534-B21 | |
| Ultra320 SCSI - Non-hot Plug | ||
| HP 146GB U320 10K NHP HDD | 356990-B21 | |
| HP 72GB U320 10K NHP HDD |
332751-B21
| |
| HP 36GB U320 15K NHP HDD |
357012-B21
| |
| | ||
| 160GB External HDD | HP External Backup Solution by Seagate |
372914-001
|
|
|
||
| Storage Controllers | HP SC44Ge Host Bus Adapter |
416096-B21
|
| 64-Bit/133MHz Single Channel Ultra320
SCSI HBA |
374654-B21
|
|
| HP PL100 SCSI RAID Controller |
355671-B21
|
|
| HP 6-Port SATA RAID Controller |
372953-B21
|
|
| 2 Port SATA RAID Cable Kit for
ML150G2 |
379093-B21
|
|
| NOTE: 2 Port SATA RAID Cable Kit (P/N: 379093-B21) required when using the HP 6-Port SATA RAID controller (P/N: 372953-B21) and supporting more than 4 SATA hard disk drives. | ||
|
|
||
| Communications | HP NC110T PCI Express Gigabit Server Adapter |
434905-B21
|
| HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter |
367132-B21
|
|
| HP NC340T PCI-X Quad Gigabit Server Adapter |
391661-B21
|
|
| HP NC360T PCI Express Dual Port Gigabit Server Adapter |
412648-B21
|
|
|
|
||
| Remote Management | HP ProLiant ML150 G2 Lights-Out 100 Remote Management Card |
373043-B21
|
|
|
||
| Tape Drives | NOTE: A separate SCSI Controller is required for connecting SCSI tape drives to this server. | |
| DAT Tape Drives | ||
| HP StorageWorks DAT 40 SCSI Internal
Tape Drive (Carbon) |
C5686B
|
|
| HP StorageWorks DAT 72 SCSI Internal Tape Drive (Carbon) |
Q1522B
|
|
| USB Tape Drives | ||
| HP StorageWorks DAT 24 USB Internal Tape Drive (Carbonite) |
DW069A
|
|
| HP StorageWorks DAT 40 USB Internal Tape Drive (Carbonite) |
DW022A
|
|
| HP StorageWorks DAT 72 USB Internal Tape Drive (Carbonite) |
DW026A
|
|
| NOTE:
For the complete listing of Tape Drive offerings for this server, please
visit: http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html |
||
|
|
||
| HP Data Protector Express Software | HP DP Express Backup Server Upgrade for ProLiant Software | BB117AP |
| HP DP Express Package for Microsoft Small Business Server | BB118AA | |
| NOTE: Please see
the HP Data Protector Express QuickSpecs for additional information regarding
the purchase of HP Data Protector Express software: http://h18000.www1.hp.com/products/quickspecs/12337_na/12337_na.html
NOTE: To obtain a free licensed copy of HP Data Protector Express for ProLiant edition software, please visit the "Protect Your Data" link accessible from your ProLiant server's System Management Homepage (SMH) software (SmartStart 7.5 or later). |
||
| | ||
| Uninterruptible Power Systems - Tower Supply | HP T750 UPS, Low Voltage |
378439-D71
|
|
|
||
| Installation of Server into Racks | Monitor/Utility Shelf (68 kg capacity) | 253449-B21 |
| 100Kg/220Lbs Sliding shelf (Graphite) NOTE: When using the100Kg/220Lbs Sliding shelf, install Stabilizer Kit for 5642 rack (PN 374493-B21). |
234672-B21 | |
| Stabilizer
Kit for 5642 rack (Graphite Carbon) NOTE: The stabilizing kit is used to prevent rack from tipping over. |
374493-B21 | |
| 600mm
G2 Stabilizer Option Kit (Graphite) NOTE: When using the100Kg/220Lbs Sliding shelf, install 600mm Stabilizer Kit for 10622, 10636 and 10642 racks. |
AF062A | |
| 800mm
Stabilizer Option Kit (Graphite) NOTE: When using the100Kg/220Lbs Sliding shelf, install 800mm Stabilizer Kit for 10842 racks. | 255488-B21 | |
| NOTE: Users wishing to place the ML150 G2 into a rack may also utilize the ML150 G2 rack kit from Rack Solutions to support both 2- and 4-post racks. http://www.racksolutions.com/hp | ||
| | ||
| HP Serial Console Server Options | HP 16-Port Serial Console Server |
AF101A
|
| HP 48-Port Serial Console Server |
AF102A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack |
AF103A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack |
AF110A
|
|
| NOTE: For additional information regarding HP KVM Switches and options, please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| USB Options | HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver) |
DC172B
|
| HP USB 04 Standard Keyboard |
DT528A#ABA
|
|
| USB 2.0 4-port HUB |
DG954A
|
|
| HP 1GB Drive Key II- USB 2.0 Flash Drive |
AG382AA
|
|
| HP 512MB DriveKey II- USB Flash Drive |
ED516AA
|
|
|
|
||
| Service and Support Offerings (HP Care Pack Services) | Hardware Services 4-Hour On-site Service | |
| 13-Hour x 5-Day Coverage, 3 Years, Electronic |
U8192E
|
|
| 24-Hour x 7-Day Coverage, 3 Years, Electronic |
U8193E
|
|
| Hardware Services Next Business Day On-Site Service | ||
| 9-Hour x 5-Day Coverage, 3 Years, Electronic |
U8184E
|
|
| Hardware Installation, Electronic |
U8195E
|
|
| NOTE: For more information, customer/resellers can contact http://www.hp.com/services/carepack. |
|
|
Memory
| HP ProLiant ML150 Generation 2 Server |
| Standard Memory |
|
512 MB of PC2700 DDR SDRAM (333MHz)
|
| Standard Memory Plus Optional Memory |
| Up to 5120 MB memory is available with the optional installation of PC2700 Registered ECC DDR SDRAM DIMM Memory kits. |
| Standard Memory Replaced with Optional Memory |
| Up to 8192 MB of memory is available with the removal of the standard 512-MB of memory and the optional installation of PC2700 Registered ECC DDR SDRAM DIMM Memory kits. |
| NOTE: Charts do not represent all possible memory configurations. Memory must be populated in one of the following ways: Slot 1 only; slots 1 and 2 only (pairs must be of the same size); or slots 1, 2, 3, and 4 (pairs must be of the same size and in the example below with slots 1 and 2 the same and slots 3 and 4 the same) |
|
Memory
|
Slot
|
||||
|
|
1
|
2
|
3
|
4
|
|
|
Standard
|
512 MB
|
Empty
|
Empty
|
Empty
|
512 MB
|
|
Optional
|
5120 MB
|
2048 MB
|
2048 MB
|
512 MB
|
512 MB
|
|
Maximum
|
8192 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
| Following are memory options available from HP: | |
| 1024 MB Advanced ECC PC2700 DDR SDRAM DIMM Memory Kit (1 x 1 GB) |
358348-B21
|
| 2048 MB Advanced ECC PC2700 DDR SDRAM DIMM Memory Kit (1 x 2 GB) |
358349-B21
|
| 512 MB Advanced ECC PC2700 DDR SDRAM DIMM Memory Kit (1 x 512 MB) |
358347-B21
|
|
|
Storage
| Hot Plug SCSI Model | ||
![]() |
A |
48x IDE CD-ROM |
| B |
Removable Media Bay (1.6" each) | |
| C | 1.44 MB Diskette Drive | |
| 1, 2, 3, 4, 5, 6 | Six Hot Plug SCSI Drive Bays | |
| Non-Hot Plug SCSI Model | ||
![]() |
A |
48x IDE CD-ROM |
| B |
Removable Media Bay (1.6" each) | |
| C | 1.44 MB Diskette Drive | |
| 1, 2, 3, 4, 5, 6 | Six Non Hot Plug SCSI Drive Bays | |
| Hot Plug SATA Model | ||
![]() |
A |
48x IDE CD-ROM |
| B |
Removable Media Bay (1.6" each) | |
| C | 1.44 MB Diskette Drive | |
| 1, 2, 3, 4, 5, 6 | Six Hot Plug SATA Drive Bays | |
| Drive Support | |||
| Quantity Supported |
Position Supported |
Controller |
|
| Removable Media | |||
| 1.44-MB Diskette Drive | Up to 1 | C | Integrated IDE (ATAPI) |
| IDE CD-ROM Drive | Up to 2 | A or B | Integrated IDE |
| 48X Combo Drive Option Kit | Up to 2 | A or B | Integrated IDE (ATAPI) |
|
|
|||
| Hard Drives (SCSI Models only) | |||
| Ultra320 SCSI | |||
|
Quantity Supported |
Position Supported |
Controller | |
|
36GB 72GB 146GB | Up to 6 | 1,2,3,4,5,6 | Slot based Single Channel Ultra3 SCSI Adapter (SCSI Models) o Optional SCSI RAID Controller |
|
| |||
| Hard Drives (SATA Models with optional HP 6-Port SATA RAID Controller) | |||
| 7,200 rpm SATA | |||
|
Quantity Supported |
Position Supported |
Controller | |
|
80GB 160GB 250GB 500GB | Up to 6 | 1,2,3,4,5,6 | Optional HP 6-Port SATA RAID Controller |
|
| |||
| Hard Drives (SATA Models) | |||
| 7,200 rpm SATA | |||
|
Quantity Supported |
Position Supported |
Controller | |
|
80GB 160GB 250GB 500GB | Up to 4 | 1,2,3,4 |
Slot based 4 port SATA Adapter (SATA Models) |
|
| |||
| Maximum Storage Capacity - SCSI Models | |
| Internal | 880GB (6 x 146GB SCSI hard drives) |
| Total | 880GB (6 x 146GB SCSI hard drives) |
| Maximum Storage Capacity - SATA Models | |
| Internal | 2TB (4 x 500GB SATA drives) or 3TB (6 X 500GB SATA drives) with optional HP 6-Port SATA RAID Controller |
| Total | 2TB (4 x 500GB SATA drives) or 3TB (6 X 500GB SATA drives) with optional HP 6-Port SATA RAID Controller |
|
| |
| Tape Drives | |||
| NOTE: A SCSI controller
needs to be purchased to operate internal SCSI devices in the SATA and Hot
Plug SCSI Model. NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following: http://h18000.www1.hp.com/products/quickspecs/north_america/10233.html |
|||
|
Quantity
Supported |
Position
Supported |
Optional Controller |
|
| HP
StorageWorks Tape Drives, USB Internal
DAT 24 USB DAT 40 USB DAT 72 USB |
1
|
B
|
Embedded USB 2.0 port |
| HP
StorageWorks Tape Drives, USB External
DAT 24 USB DAT 40 USB DAT 72 USB |
1 per USB port
|
External
|
USB 2.0 port |
| HP StorageWorks Tape Drives, Internal DAT 24 DAT 40 DAT 72 |
1
|
B
|
64-Bit/133MHz Single Channel Ultra320 SCSI HBA ALL |
| HP
StorageWorks Tape Drives, External DAT 24 DAT 40 DAT 72 |
1
|
External
|
64-Bit/133MHz Single Channel Ultra320 SCSI HBA ALL |
|
|
Power Specifications
|
Part Number | 372986-001 |
| Spare Kit | 372783-001 |
| Operational Input Voltage Range (Vrms) | 90 to 135 and 180 to 264 V ac full ranging |
| Frequency
Range (Nominal) (Hz) | 47 to 63 Hz |
| Nominal Input Voltage (Vrms) |
100
|
115
|
208
|
220
|
230
|
240
|
| Max Rated Output Wattage Rating |
600
|
600
|
600
|
600
|
600
|
600
|
| Nominal Input Current (A rms) |
10
|
10
|
5
|
5
|
5
|
5
|
| Max Rated Input Wattage Rating (Watts) |
800
|
800
|
750
|
750
|
750
|
750
|
| Max. Rated VA (Volt-Amp) |
800
|
800
|
780
|
780
|
780
|
780
|
| Efficiency (%) |
75
|
77
|
79
|
80
|
80
|
80
|
| Power Factor |
0.95
|
0.95
|
0.9
|
0.9
|
0.9
|
0.9
|
| Leakage Current (mA) |
3.5mA
|
3.5mA
|
3.5mA
|
3.5mA
|
3.5mA
|
3.5mA
|
| Maximum Inrush Current (A peak) |
50
|
50
|
50
|
50
|
50
|
50
|
| Maximum Inrush Current duration (mS) |
3
|
3
|
3
|
3
|
3
|
3
|
| System Specifications |
|
Power**
|
|
| HP ProLiant ML150 G2 Fully Configured |
(see**)
|
| Fully Loaded System Input Wattage (W) |
420W
|
| Fully Loaded System Input Current (A rms) |
5A @ 115V, 2.5A @ 230V
|
| Fully Loaded System Thermal (BTU- Hr)r) |
1435 BTU
|
| Fully Loaded System VA (Volt-Amp) |
420
|
| System Leakage with all power supplies loaded (mA) |
3.5mA
|
| System Inrush Current with all power supplies loaded (A) |
50A
|
| Power cord requirements |
Nema 5-15P to IEC320-C13
|
|
IEC320-C13 to IEC320-C14
|
|
| **Power shown is for a fully configured system consisting of | |
| (2) CPU (4) double-sided DIMMs (6) HDDs SCSI (1) CD-ROM (0) DVD-ROM (1) 1.44MB Diskette Drive (1) PCI express (1) PCI (3) PCI X (1) 600 watts power supply |
|
Power Cord Part Number
|
|
| 121565-001 |
|
|
Technical Specifications
| System Unit | Dimensions (HxWxD) (with feet) | 17.56 in x 8.03 in x 21.3 in (44.6 x 20.4 x 54.1 cm) | |
| Weight (approximate) | 42 lb (17 kg) | ||
| Input Requirements
(per power supply) |
Range Input Voltage | 90 to 135 VAC/180 to 265 VAC | |
| Normal Line Voltage | 100 to 120/200 to 240 VAC | ||
| Line Frequency | 50 to 60 Hz | ||
| Rated Input Current | load 8A at 115VAC, 4A at 230VAC | ||
| BTU Rating | 1907 BTU | ||
| SCSI Connectors (SCSI Models only) |
One internal LVD/SE connector for U320 devices | ||
| Power Supply Output Power (per power supply) | Rated Steady-State Power | 600W | |
| Maximum Peak Power | 660W | ||
| Temperature Range | Operating | 50° to 93° F (10° to 35° C) | |
| Shipping | -40° to 150° F (-40° to 66° C) | ||
| Relative Humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 90% | ||
| Acoustic Noise | Idle (Fixed Disk Drives Spinning) | ||
L WAd (BELS) |
5.8 | ||
| Operating (Random Seeks to Fixed Disks) | |||
L WAd (BELS) |
6.0 | ||
| *NOTE:
All temperature ratings shown are for sea level. An altitude derating of
1° C per 304.8 m (1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable.
No direct sunlight allowed. Upper operating limit is 3,048m (10,000 ft)
or 70 Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or
30.3KPa/4.4 psia. System performance may be reduced if operating with a
fan fault or above 30C. **NOTE: Storage maximum humidity of 90% is based on a maximum temperature of 45° C (113° F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa. |
|||
|
|
|||
|
Non-Hot Plug Ultra320 SCSI Hard Drives | 36.4-GB
Ultra320 SCSI 15,000 rpm Hard Drive 332751-B21 | Capacity | 36,419.2 MB | |
| Height | 1 in (2.54 cm) | |||
| Width | 4 in (10.16 cm) | |||
| Interface | Ultra320 SCSI | |||
| Transfer Rate
Synchronous (Maximum) | 320 MB/s | |||
| Seek Time (typical reads, including settling) | Single Track | 0.4 ms | ||
| Average | 3.8 ms | |||
| Full-Stroke | 8 ms | |||
| Rotational Speed | 15,000 rpm | |||
| Physical Configuration | Bytes/Sector | 512 | ||
| Logical Blocks | 71,132,000 | |||
| Operating Temperature | 50° to 95° F (10° to 35° C) | |||
|
| ||||
| 48X Max IDE (ATAPI) CD-ROM Drive | Disk | Applicable Disk | CD-ROM, CD-XA, CD-DA (Mode 1, Mode 2, Form 1 and 2) |
| Photo CD (Single and Multi-session) | |||
| Mixed Mode (Audio and Data combined) | |||
| CD-R | |||
| Capacity | 540 MB (Mode 1, 12 cm) | ||
| 650 MB (Mode 2, 12 cm) | |||
| Block Size | Mode 1 | 2,048 bytes | |
| Mode 2 | 2,340 bytes, 2,336 bytes | ||
| CD-DA | 2,352 bytes | ||
| CD-XA | 2,328 bytes | ||
| Interface |
IDE (ATAPI) |
||
| Access Times (typical) | Random |
<100 ms | |
| Full-Stroke | <150 ms | ||
| Data Transfer Rate | Sustained |
3000 to 7200 KB/s (20X to 48X) | |
| Burst |
150 KBps to 7,200 KBps | ||
| Bus Rate | 16.7 MBp | ||
| Cache Buffer | 128 KB |
||
| Start-up Time (typical) | < 7 seconds |
||
| Stop Time | < 4 seconds |
||
| Laser Parameters | Type |
Semiconductor Laser GaA1As | |
| Wave Length | 780 ± 25 nm | ||
| Operating Conditions | Temperature |
41° to 113° F (5° to 45° C) | |
| Humidity |
10% to 80% | ||
| Dimensions |
(HxWxD, maximum) |
1.7 x 5.85 x 8.11 in (42.9 x 150 x 208 cm) | |
| Weight | 2.09 lb (0.95 kg) | ||
|
|
|||
| Slot based Single Channel Ultra3 SCSI Adapter (SCSI Models only) | Drives Supported |
Up to 16 SCSI devices Wide |
| Data Transfer Method |
64-bit 66-MHz PCI-X bus-master | |
| SCSI Channel Transfer Rate |
320 MB/s per channel | |
| Maximum Transfer Rate per PCI
Bus (peak) |
267 MB/s per channel | |
| SCSI Protocols | Wide Ultra4 SCSI, Wide Ultra2
SCSI, Wide Ultra SCSI-3, Fast-Wide SCSI-2, and Fast SCSI-2 Fast SCSI-2 |
|
| Electrical Protocol |
Low Voltage Differential (LVD) | |
| SCSI Termination |
Active Termination | |
| External SCSI Connectors | None | |
|
|
||
| Slot based 4 port SATA controller (SATA Model Only) | SATA Protocol |
SATA 1.5Gb/s |
| SATA Ports |
4 internal | |
| Port transfer rate |
1.5 Gb/s total | |
| Drives Supported |
Up to 4 SATA HDDs | |
| Data Transfer Method | 32-bit/66-MHz PCI-X bus-master | |
| Storage Capacity |
up to 1TB (4x 250GB hot plug 1" SATA HDD) | |
| PCI |
3.3 volt PCI slot compatibility only | |
|
|
||
| Broadcom 5721 PCI-Express Gigabit NIC (embedded) 10/100/1000 WOL (Wake on LAN) | Network Interface |
Ethernet Standards: IEEE 802.3, 802.3u, 802.3ad, and 802.3ab, 802.1x, 802.1Q and 802.1p | |
| Data Transfer Method |
PCI Express | ||
| Network Transfer Rate |
10/100/1000 Mbps, Half- and full-duplex | Auto-negotiated speeds of 10/100/1000 Mbps in both half and full duplex | |
| Connector |
RJ-45 connector | ||
| Cable Support | Category 5 or higher UTP wiring | ||
|
|
|||
|
© Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and
services are set forth in the express warranty statements accompanying such products
and services. Nothing herein should be construed as constituting an additional
warranty. HP shall not be liable for technical or editorial errors or omissions
contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |