Overview
|
HP Monitored Power Distribution Unit (PDU) | |||
| The HP Monitored PDUs allow administrators and facility personnel to monitor current draw directly at the rack and per PDU. HP Monitored PDUs are available in both 1 phase and 3 phase and in single and dual input. Power capacity per PDU ranges from ranging from 4.9 kVA up to 22 kVA to provide flexibility in deployment. Available PDU's include full rack models with 39 receptacles on the single input models or with 78 receptacles on the dual input models. Half rack versions are single input and are available in a popular single phase model with 24 C-13 and 3 C-19 receptacles and a high capacity 3 phase model with 12 C-19 receptacles for use in dense BladeSystem environments. The optional PDU Management Module allows for remote monitoring of the PDUs across the network. | |||
| Full
Rack Vertical PDU Model (Ideal for 36U to 47U racks) | |||
![]() | |||
| 1. | 3 x C-19 outlets per input | 6. | Power cords |
| 2. | 36 x C-13 outlets per input | 7. | Mounting and cord retention brackets |
| 3. | Color coded load segments | 8. | Serial number label |
| 4. | Front Panel Display and communications port for PDU Management module | 9. | Model number |
| 5. | Color coded circuit breakers | ||
|
Half Rack Vertical PDU Models S348 | |||
![]() | |||
| 1. | Front Panel Display and communications port for PDU Management module | 4. | Serial Number label |
| 5. | Model number | ||
| 2. | 12 x Color Coded C-19 outlets for Load Segmentation | 6. | Power cord |
| 3. | Color coded circuit breakers | 7. | Mounting and cord retention brackets |
|
Half Rack Vertical PDU Models S124 | |||
![]() | |||
| 1. | 3 x C19 outlets | 5. | Front Panel Display and communications port for PDU Management module |
| 2. | Color
Coded C19 and C13 outlets for Load Segmentation | 6. | Mounting and cord retention brackets |
| 3. | 24 x C13 outlets | 7-9. | Color coded circuit breakers |
| 4. | Power cord | ||
| What's New |
|
|
|
| Models | |
| HP Monitored Power Distribution Unit: Full Rack Version | |
| HP 17.3 kVA S2324 Monitored PDU- dual input, 3Ø, 24A |
AF503A
|
| HP 8.6 kVA S1324 Monitored PDU- single input, 3Ø, 24A |
AF504A
|
| HP 16.6 kVA S2140 Monitored PDU- dual input, 1Ø, 40A |
AF505A
|
| HP 8.3 S1140 Monitored PDU- single input, 1Ø, 40A |
AF506A
|
|
|
|
| HP Monitored Power Distribution Unit: Half Rack Version | |
| HP 4.9 kVA S124 Monitored PDU- single input, 1Ø, 24A |
AF914A
|
| HP 14.4 kVA S340 Monitored PDU- single input, 3Ø, 40A | AF536A |
| HP 17.3 kVA S348 Monitored PDU- single input, 3Ø, 48A | AF916A |
| NOTE: "Ø" = number of electrical phases at input. | |
|
|
Product Features
| Target Applications and Markets |
|
|
|
|
| Customer Challenges/Requirements |
|
|
| |
| Model Features - Full-Rack Vertical PDU |
|
| | |
| Model Features - Half-Rack Vertical PDU |
|
|
| |
| Optional HP PDU Management Module |
NOTE:
For additional information on the PDU Management Module please go to: |
| Optional HP PDU Management Module |
NOTE:
For additional information on the PDU Management Module please go to: |
|
|
Service and Support, HP Care Pack, and Warranty Information
|
HP Care Pack services provide a range of life cycle support options that
let you choose the service levels that meet your business requirements,
from basic to mission-critical. A full range of HP Care Pack hardware and software services are available
including:
NOTE: For more information on HP Care
Pack services, contact any of our worldwide sales offices or resellers
or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack NOTE: The information contained
herein is subject to change without notice and is provided "as is"
without warranty of any kind. |
|
|
Related Options
| HP PDU Extension Bars | HP C-13 PDU Extension
Bar Kit, pair NOTE: Each extension bar has a C-20 input cord and 7 x C-13 receptacles. | AF500A |
| HP Fixed Cord Extension Bar
Kit, pair NOTE: Each extension bar has a C-20 input cord and 7 attached 13 inch C-13 power cords for use with 1U servers. | 351655-B21 | |
| NOTE: Extension bars may be used with any HP Monitored PDU that has C-19 outlets. | ||
| | ||
| HP PDU Management Module | HP PDU Management Module | AF400A |
| | ||
| HP Power Cables | 10A, IEC320 C-14 to IEC 320 C-13 Cables, 4.5ft (1.37m), 15 pack | 142257-007 |
| 10A, IEC320 C-14 to IEC 320 C-13 Cables, 4.5ft (1.37m), single 15 pack | 142257-006 | |
| 10A, IEC320 C-14 to IEC 320 C-13 Cables, 1.6ft (0.5m), single pack | 142257-B28 | |
| NOTE: For more information on HP power cords please go to: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/power-cord-option-kits.pdf | ||
| | ||
| Service
and Support Offerings (HP Care Pack Services) | Hardware Installation (Electronic) | U2871E |
|
|
Technical Specifications
| Full Rack Vertical PDU Dual Input Models |
|
Model Number
|
S2324
|
S2140
|
|
| Part number |
AF503A
|
AF505A
|
|
| Input ratings | |||
|
Voltage (VAC)
|
~A: 200-240V 60/50Hz 3Ø Delta
|
~A: 200-240V 60/50Hz 1Ø
|
|
|
~B: 200-240V 60/50Hz 3Ø Delta
|
~B: 200-240V 60/50Hz 1Ø
|
||
| Current (Amps) | |||
| Branch circuit requirements |
208V, 3Ø, 4-wire, 30A
|
200-240V, 3-wire 50A
|
|
| Input plug/cord rating |
NEMA L15-30P x 2
|
Non-NEMA Locking CS8265C, 50A x 2
|
|
| Input cord length |
72in (1.83m)
|
72in (1.83m)
|
|
| Facility receptacle needed |
NEMA L15-30R x 2
|
Hubbell CS8264C, CS8269, or equivalent x2
|
|
| De-rated capacity |
24A
|
40A
|
|
| Output ratings | |||
|
Voltage (VAC)
|
~A: 200-240V 60/50Hz 3Ø
|
~A: 200-240V 60/50Hz 1Ø
|
|
|
~B: 200-240V 60/50Hz 3Ø
|
~B: 200-240V 60/50Hz 1Ø
|
||
| Current (Amps) | |||
| Outlet rating | C-13 |
10A
|
10A
|
| C-19 |
16A
|
16A
|
|
| Load segment | L3 |
~A: 13.86A
|
~A: 20A
|
|
~B: 13.86A
|
~B: 20A
|
||
| L2 |
~A: 13.86A
|
~A: 20A
|
|
|
~B: 13.86A
|
~B: 20A
|
||
| L1 |
~A: 13.86A
|
~A: 20A
|
|
|
~B: 13.86A
|
~B: 20A
|
||
|
Maximum Total |
~A: 41.6A
|
~A: 40A
|
|
|
~B: 41.6A
|
~B: 40A
|
||
| Power (Watts) | |||
| Per Line Cord |
~A: 8.6 kVA
|
~A: 8.3 kVA
|
|
|
~B: 8.6 kVA
|
~B: 8.3 kVA
|
||
| PDU Total |
17.2 kVA
|
16.6 kVA
|
|
| Number of outlets | |||
| Load Segment / Line Cord | C-13 |
~A: 36 (12 per segment)
|
~A: 36 (12 per segment)
|
|
~B: 36 (12 per segment)
|
~B: 36 (12 per segment)
|
||
| C-19 |
~A: 3 (1 per segment)
|
~A: 3 (1 per segment)
|
|
|
~B: 3 (1 per segment)
|
~B: 3 (1 per segment)
|
||
| PDU total | C-13 |
72
|
72
|
| C-19 |
6
|
6
|
|
| Dimensions & Weights | |||
| Product |
Product
|
Product
|
Product
|
| Height |
60 inches (1524 mm)
|
60 inches (1524 mm)
|
|
|
Width
|
3.75 inches (95.25 mm)
|
3.75 inches (95.25 mm)
|
|
|
Depth
|
2.0 inches (50.8 mm) @ outlets
|
2.0 inches (50.8 mm)@ outlets
|
|
|
Weight
|
27.5 pounds (12.47 Kg)
|
37.5 pounds (37.5 Kg)
|
|
| Shipping |
Shipping
|
Shipping
|
Shipping
|
| Height |
66.7 inches (1694 mm)
|
66.7 inches (1694 mm)
|
|
|
Width
|
11.0 inches (279.4 mm)
|
11.0 inches (279.4 mm)
|
|
|
Depth
|
11.3 inches (287.02 mm)
|
11.3 inches (287.02 mm)
|
|
|
Weight
|
42.3 pounds (19.18 Kg)
|
42.3 pounds (19.18 Kg)
|
|
| Full Rack Vertical PDU Single Input Models |
|
Model number
|
S1324
|
S1140
|
|
| Part number |
AF504A
|
AF506A
|
|
| Input ratings | |||
|
Voltage (VAC)
|
200-240V 60/50Hz 3Ø Delta
|
200-240V 60/50Hz
1Ø |
|
| Current (Amps) | |||
| Branch circuit requirements |
208V, 3Φ, 4-wire, 30A
|
200-240V, 3-wire 50A
|
|
| Input plug/cord rating |
NEMA L15-30P
|
Non-NEMA Locking CS8265C, 50A
|
|
| Input cord length |
72in (1.83m)
|
72in (1.83m)
|
|
| Facility receptacle needed |
NEMA L15-30R
|
Hubbell CS8264C or CS8269, 50A or equivalent
|
|
| De-rated capacity |
24A
|
40A
|
|
| Output ratings | |||
|
Voltage (VAC)
|
200-240V 60/50Hz 1U
|
200-240V 60/50Hz 1U
|
|
| Current (Amps) | |||
| Outlet rating | C-13 |
10A
|
10A
|
| C-19 |
16A
|
16A
|
|
| Load segment | L3 |
13.86A
|
20A
|
| L2 |
13.86A
|
20A
|
|
| L1 |
13.86A
|
20A
|
|
|
Maximum Total
|
41.6A
|
40A
|
|
| Power (kVA) | |||
| Per line cord |
8.6 kVA
|
8.3 kVA
|
|
| PDU Total |
8.6 kVA
|
8.3 kVA
|
|
| Number of outlets | |||
| Load segments | C-13 |
3 load segments
12 x C-13 outlets per segment 1 load segment per electrical phase |
3 load segments
12 x C-13 outlets per segment |
| C-19 |
3 (1 per segment)
|
3 (1 per segment)
|
|
| PDU total | C-13 |
36
|
36
|
| C-19 |
3
|
3
|
|
| Dimensions & Weights | |||
| Product |
Height
|
60 inches (1524 mm)
|
60 inches (1524 mm)
|
|
Width
|
1.9 inches (48.26 mm)
|
1.9 inches (48.26 mm)
|
|
|
Depth
|
2.0 inches (50.8 mm) @ outlets
|
2.0 inches (50.8 mm)@ outlets
|
|
|
Weight
|
25.1 pounds (11.38 Kg)
|
25.1 pounds (11.38 Kg)
|
|
| Shipping |
Height
|
64.8 inches (1645.2 mm)
|
64.8 inches (1645.2 mm)
|
|
Width
|
7.8 inches (198.12 mm)
|
7.8 inches (198.12 mm)
|
|
|
Depth
|
9.5 inches (241.3 mm)
|
9.5 inches (241.3 mm)
|
|
|
Weight
|
26.1 pounds (11.83 Kg)
|
26.1 pounds (11.83 Kg)
|
|
| Half Rack Vertical PDU Models |
| Model number | S340 |
S348
|
|
| Part number | AF536A |
AF916A
|
|
| Input ratings | |||
| Voltage (VAC) |
200-240V 60/50Hz
3Ø Delta |
200-240V 60/50Hz
3Ø Delta |
|
| Current (Amps) | |||
| Branch circuit requirements |
208V, 3Ø, 4-wire, 60A
|
208V, 3Ø, 4-wire, 60A
|
|
| Input plug/cord rating | Hubbell CS8365C 3 pole, 4 wire Twist lock |
IEC60309 460P9 Watertight
3 Pole, 4 wire, 250VAC, 60A |
|
| Input cord length |
96 in (2.43m)
|
96 in (2.43m)
|
|
| Facility receptacle needed | Hubbell CS8365C 3 pole, 4 wire Twist lock |
IEC309 3 Pole, 4 wire, 250VAC, 60A
Hubbell WBL460C9W, WBL460R9W, or equivalent |
|
| De-rated capacity |
48A
|
||
| Output ratings | |||
| Voltage (VAC) |
200-240V 60/50Hz 1 Ø
|
200-240V 60/50Hz 1 Ø
|
|
| Current (Amps) | |||
| Outlet rating | C-19 |
16A
|
16A
|
| Load segment | L6 |
20A
|
20A
|
| L5 |
20A
|
20A
|
|
| L4 |
20A
|
20A
|
|
| L3 |
20A
|
20A
|
|
| L2 |
20A
|
20A
|
|
| L1 |
20A
|
20A
|
|
| Power (kVA) | 14.4 kVA |
17.3 kVA
|
|
| Maximum amperage per phase | 23 amps / phase | 27.7 amps / phase | |
| PDU Total | 14.4 kVA |
17.3 kVA
|
|
|
Number of outlets
|
|||
| Load segment / line cord |
C-19
|
6 load segments 2 outlets per segment 2 load segments per electrical phase |
6 load segments
2 outlets per segment 2 load segments per electrical phase) |
| PDU total |
C-19
|
12 |
12
|
|
Dimensions & Weights
|
|||
| Product | Height |
28.32 inches (719.2 mm)
|
28.32 inches (719.2 mm)
|
| Width |
3.78 inches (96mm)
|
3.78 inches (96mm)
|
|
| Depth |
3.70 inches (94mm)
|
3.70 inches (94mm)
|
|
| Weight |
24.2 lbs (11 Kg)
|
24.2 lbs (11 Kg)
|
|
| Shipping | Height |
33.25 inches (844.55 mm)
|
33.25 inches (844.55 mm)
|
| Width |
12.9 inches (327.66 mm)
|
12.9 inches (327.66 mm)
|
|
| Depth |
10.2 inches (259.08 mm)
|
10.2 inches (259.08 mm)
|
|
| Weight |
31 lbs (14.1 Kg)
|
31 lbs (14.1 Kg)
|
|
| Full Rack Vertical PDU Single Input Models |
| Model number |
S124 | |
| Part number | AF914A | |
| Input ratings | ||
| Voltage
(VAC) | 200-240V
60/50Hz 1U | |
| Current (Amps) | ||
| Branch circuit requirements | 208V,
1Ø, 3-wire, 30A | |
| Input Plug/Cord Rating | NEMA
L6-30P | |
| Input cord length | 120
in (3.05m) | |
| Facility receptacle needed | NEMA
L6-30R | |
| De-rated capacity | 24A | |
| Output ratings | ||
| Voltage (VAC) | 200-240V
60/50Hz 1U | |
| Current (Amps) | ||
| Outlet rating | C-13 |
10A |
| C-20 |
16A | |
| Load segment | L3 |
20A |
| L2 | 20A | |
| L1 |
20A | |
| Total |
24A | |
| Power (kVA) | 4.9
kVA | |
| PDU Total | 4.9
kVA | |
|
Number of outlets | ||
| Load segments | C-13 |
3 load segments 8 x C-13 outlets per segment |
| C-19 |
3 (1 per segment) | |
| PDU total | C-13 |
24 |
|
C-19 |
3 | |
|
Dimensions & Weights | ||
| Product | Height |
28.86 inches (733mm) |
| Width |
3.78 inches (96mm) | |
| Depth |
1.97 inches (50mm) | |
| Weight | ||
| Shipping | Height |
34.4 inches (874.7 mm) |
| Width |
7.94 inches (201.6mm) | |
| Depth |
5.13 inches (130.2 mm) | |
| Weight |
13.2 pounds (5.99 Kg) | |
| Disclaimer: HP makes no recommendations regarding power connector manufactures. The manufacturers and model numbers listed in the above tables are strictly for the purpose of providing examples. Please consult a licensed professional to determine the best connector or receptacle for your specific needs. | |||
|
Environment-friendly Products and Approach | End-of-life Management and Recycling | Hewlett-Packard
offers end-of-life HP product return, trade-in, and recycling programs in many
geographic areas. For trade-in information, please go to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will be recycled,
recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
| | ||
| © Copyright 2008 Hewlett-Packard Development
Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |