Overview
|
HP ProLiant ML310 Generation 2 (G2) | ||
![]() |
||
| 1. 48x IDE (ATAPI) CD-ROM | 5. Four DIMM Sockets, for up to 4GB DDR memory |
| 2. Removable Media Bays | 6. System Fan |
| 3. Four Hot-Plug (shown) or Four Non hot-plug (not shown) Drive Bays | 7. 350W Power Supply |
| 4. Four Expansion Slots (Two PCI-X, One PCI, and One PCI Express) | |
|
|
|
At A Glance
|
|
|
Standard Features
| Processor One of the following |
Intel Pentium 4 - 3.4
GHz/800-2MB L2 NOTE: See "Configuration Information - Factory Integrated Models" section |
| Intel Pentium 4 - 3.2 GHz/800-2MB L2 | |
| Intel Pentium 4 - 3.4 GHz/800-1MB L2 | |
| Intel Pentium 4 - 3.2 GHz/800-1MB L2 | |
| Intel Pentium 4 - 3.0
GHz/800-1MB L2 NOTE: See "Configuration Information - Factory Integrated Models" section |
|
| Intel Celeron 2.8
GHz/533-256KB L2 NOTE: See "Configuration Information - Factory Integrated Models" section |
|
|
|
|
| Cache
Memory One of the following depending on Model |
Integrated 1MB level 2 ECC cache (Pentium 4 models) |
| Integrated 2MB level 2 ECC cache (Pentium 4 models) | |
| Integrated 256KB level 2 ECC cache (Celeron models) | |
|
|
|
| Memory Protection | Advanced ECC |
|
|
|
| Memory | Type |
PC3200 DDR SDRAM (400MHz) |
| Standard |
512 MB (1 x 512 MB) | |
| Maximum | 4 GB | |
|
|
||
| Network Controller | Embedded NC7761 PCI 10/100/1000T Gigabit network adapter |
|
|
|
| Expansion Slots |
Slot Number
|
Bus Speed
|
Maximum Card Length
|
Hot Plug
|
PCI Voltage |
|
1
|
64-bit/100MHz PCI-X
|
12.3
|
No
|
3.3V
|
|
|
2
|
64-bit/100MHz PCI-X
|
12.3
|
No
|
3.3V
|
|
|
3
|
PCI Express x4
(x8 connector) |
12.3
|
No
|
N/A
|
|
|
4
|
32-bit/33MHz PCI
|
12.3
|
No
|
3.3V
|
|
|
|
|||||
| Storage Controllers | Single Channel Ultra320 SCSI Adapter (SCSI Models) OR |
| Integrated four port SATA controller
with integrated SATA RAID 0, 1 (SATA Models) NOTE: Integrated SATA RAID functionality supports 2 hard drives. |
|
| NOTE: See the "Storage" section of these QuickSpecs for information on controllers and cables required to support SATA drive configurations | |
|
|
|
| Storage | Diskette Drive | Optional 1.44 MB Diskette Drive |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
|
|
||
| Maximum Internal Storage | Hot Plug SCSI | 1.2TB | 4 x 300GB Ultra320 |
| Non-Hot Plug SCSI | 587GB | 4 x 146GB Ultra320 | |
| Hot
Plug SAS (3.5") | 587GB | 4 x 146GB SAS | |
| Hot Plug SATA (3.5") | 2.0TB | 4 x 500GB SATA | |
| Non-Hot Plug SATA | 320GB | 4 x 80GB SATA | |
| NOTE: See the "Storage" section of these QuickSpecs for information on controllers and cables required to support SATA and SAS drive configurations | |||
| | |||
| Interfaces | Parallel | 1 |
| Serial | 1 | |
| Pointing Device (Mouse) | 1 | |
| Graphics | 1 | |
| Keyboard | 1 | |
| USB | 4 (2 front, 2 rear) NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html |
|
| Dedicated USB | 1 (available for USB tape connectivity) | |
| Network RJ-45 (Ethernet) | 1 | |
|
|
||
| Graphics | Integrated ATI RAGE XL Video Controller with 8MB SDRAM Video Memory |
|
|
|
| Form Factor | Tower (5U) (Tower to Rack Enabling Option Kit (PN 238547-B22) available) |
|
|
|
|
ProLiant Essentials Foundation Pack Software |
| ||
| |||
| |||
| |||
| |||
| |||
| |||
| NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. | |||
| | |||
| Industry Standard Compliance | ACPI V1.0b Compliant PCI 2.2 Compliant PCI-X 1.0 Compliant PCI-Express 1.0a Compliant PXE Support WOL Support Microsoft Logo certifications Novell Logo certifications USB2.0 |
|
|
|
| Manageability | HP Systems Insight Manager Online ROM Flash Utility Automatic Server Recovery-2 (ASR-2) Drive Parameter Tracking (with Smart Array Controller) Dynamic Sector Repairing (with Smart Array Controller) Pre-Failure Warranty (covers processors, memory and SCSI hard drives) BIOS Serial Console |
|
|
|
| Security | Power-on password Setup password Diskette boot control Power switch security Intruder Alert Message |
|
|
|
| Server Power Cords | All models ship with one 6' standard low-line country specific power cord. |
|
|
|
| UPS and PDU Power Cord Matrix |
Please see the UPS and PDU cable
matrix that lists cable descriptions, requirements, and specifications for
UPS and PDU units: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf. |
|
|
|
| Power Specifications |
To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool located at URL: http://h30099.www3.hp.com/configurator/powercalcs.asp |
|
|
|
| Power Supply | 350 Watts, PFC (Power Factor Correcting) |
|
|
|
| System Fans | 1 - Non-hot
plug, Non-redundant system fan NOTE: Does not include fans in CPU heatsink or power supply. |
|
|
|
| Required Cabling | For required cabling
information, refer to the Web site at http://h18000.www1.hp.com/products/servers/ProLiantML310/. |
| | |
| OS Support | Microsoft Windows Server 2003
(Standard & Web Edition) Microsoft Small Business Server 2003 Microsoft Windows 2000 Server Novell NetWare Linux (Red Hat, SuSE, and UnitedLinux) VMware Virtualization Software |
| NOTE:
For a more complete and up-to-date listing of supported OSs and versions,
please visit our OS Support Matrix at: http://www.hp.com/go/supportos NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant ML310, please see: http://h18023.www1.hp.com/support/files/server/us/index.html. NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux Web site at: http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html NOTE: For more complete and up-to-date information on how to buy server operating systems from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html |
|
|
|
|
| Rack Airflow Requirements |
Rack 10000 series Cabinets CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://h18000.www1.hp.com/products/servers/ProLiantdl760/index.html. | |
| | |
| Factory Express Portfolio for Servers and Storage | HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
|
|
|
| Custom Builder | Please see the Enterprise Configurator for configuration assistance at: http://www.hp.com/products/configurator. |
| | |
| HP ProLiant Smart Buys |
The
HP Smart Buy program offers mainstream business solutions at competitive
prices with excellent availability and superior HP quality. It offers a
wide range of industry-leading HP products at compelling prices, allowing
you to receive richer configurations with additional options. NOTE: For detailed specification information on ProLiant Smart Buys please click on the following link: ftp://ftp.compaq.com/pub/products/servers/smartbuys.pdf |
| | |
| Service and Support |
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of resellers and service providers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. NOTE: Limited warranty includes 1 year parts, 1 year labor, 1 year on-site support. Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware and software services are available including:
HP Care Pack services include coverage for the HP branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to 3kVA; these items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. |
| NOTE: For more
information on HP Care Pack services, contact any of our worldwide sales
offices or resellers or visit our worldwide Web site on the internet at:
http://www.hp.com/hps/carepack NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at: http://www.hp.com/hps NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html |
|
|
Models
| NOTE: For detailed specification information on ProLiant Smart Buys please click on the following link: ftp://ftp.compaq.com/pub/products/servers/smartbuys.pdf. | ||
| ML310T02 3.4/800-1M
HP-SCSI 376793-001 |
Processor(s) | (1) Intel Pentium 3.40 GHz (standard) |
| Cache Memory | 1MB Level 2 cache | |
| Memory | 512 MB (Standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7761 PCI 10/100/1000T Gigabit network adapter | |
| Storage Controller | Single Channel Ultra320 SCSI controller in PCI slot | |
| Hard Drives | None ship standard (up to 4 hot plug SCSI drives supported) | |
| Internal Storage | 1.20 TB maximum hot plug SCSI (with optional hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | None ship standard (Optional 1.44 MB Diskette Drive) | |
| Form Factor | Tower (5U) (Tower to Rack Enabling Option Kit available) | |
|
|
||
| ML310T02 3.4/800-1M
HP-SATA/SAS 376794-001 |
Processor(s) | (1) Intel Pentium 3.40 GHz (standard) |
| Cache Memory | 1MB Level 2 cache | |
| Memory | 512 MB (Standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7761 PCI 10/100/1000T Gigabit network adapter | |
| Storage Controller | Four port Integrated SATA Controller | |
| Hard Drives | None ship standard (up to 4
hot plug SATA or SAS drives supported) NOTE: See the "Storage" section of these QuickSpecs for information on controllers and cables required to support SATA and SAS drive configurations |
|
| Internal Storage | 2.0 TB maximum hot plug SATA (with optional hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | None ship standard (Optional 1.44 MB Diskette Drive) | |
| Form Factor | Tower (5U) (Tower to Rack Enabling Option Kit available) | |
|
|
||
| ML310T02 3.4/800-1M
NHP-SCSI 378247-002 |
Processor(s) | (1) Intel Pentium 3.40 GHz (standard) |
| Cache Memory | 1MB Level 2 cache | |
| Memory | 512 MB (Standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7761 PCI 10/100/1000T Gigabit network adapter | |
| Storage Controller | Single Channel Ultra320 SCSI controller in PCI slot | |
| Hard Drives | (1) 36.4 GB Ultra320 SCSI | |
| Internal Storage | 587.2 GB maximum NHP SCSI (with optional hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | None ship standard (Optional 1.44 MB Diskette Drive) | |
| Form Factor | Tower (5U) (Tower to Rack Enabling Option Kit available) | |
|
|
||
| ML310T02 3.4/800-1M
NHP SATA80 381833-002 |
Processor(s) | (1) Intel Pentium 3.40 GHz (standard) |
| Cache Memory | 1MB Level 2 cache | |
| Memory | 512 MB (Standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7761 PCI 10/100/1000T Gigabit network adapter | |
| Storage Controller | Four port Integrated SATA Controller | |
| Hard Drives | (1) 80GB Non hot plug SATA drive | |
| Internal Storage | 320 GB maximum NHP SATA (with
optional drives) NOTE: See the "Storage" section of these QuickSpecs for information on controllers and cables required to support SATA drive configurations |
|
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | None ship standard (Optional 1.44 MB Diskette Drive) | |
| Form Factor | Tower (5U) (Tower to Rack Enabling Option Kit available) | |
|
|
||
| ML310T02 3.2/800-2M
HP SCSI 381839-001 |
Processor(s) | (1) Intel Pentium 3.20 GHz (standard) |
| Cache Memory | 2MB Level 2 cache | |
| Memory | 512 MB (Standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7761 PCI 10/100/1000T Gigabit network adapter | |
| Storage Controller | Single Channel Ultra320 SCSI controller in PCI slot | |
| Hard Drives | None ship standard (up to 4 hot plug SCSI drives supported) | |
| Internal Storage | 1.20 TB maximum hot plug SCSI (with optional hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | None ship standard (Optional 1.44 MB Diskette Drive) | |
| Form Factor | Tower (5U) (Tower to Rack Enabling Option Kit available) | |
|
|
||
| ML310T02 3.2/800-2M
HP SATA/SAS 381838-001 |
Processor(s) | (1) Intel Pentium 3.20 GHz (standard) |
| Cache Memory | 2MB Level 2 cache | |
| Memory | 512 MB (Standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7761 PCI 10/100/1000T Gigabit network adapter | |
| Storage Controller | Four port Integrated SATA Controller | |
| Hard Drives | None ship standard (up to 4
hot plug SATA or SAS drives supported) NOTE: See the "Storage" section of these QuickSpecs for information on controllers and cables required to support SATA and SAS drive configurations |
|
| Internal Storage | 2.0 TB maximum hot plug SATA (with optional hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | None ship standard (Optional 1.44 MB Diskette Drive) | |
| Form Factor | Tower (5U) (Tower to Rack Enabling Option Kit available) | |
|
|
||
| ML310T02 3.2/800-1M
HP-SCSI 376871-001 |
Processor(s) | (1) Intel Pentium 3.20 GHz (standard) |
| Cache Memory | 1MB Level 2 cache | |
| Memory | 512 MB (Standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7761 PCI 10/100/1000T Gigabit network adapter | |
| Storage Controller | Single Channel Ultra320 SCSI controller in PCI slot | |
| Hard Drives | None ship standard (up to 4 hot plug SCSI drives supported) | |
| Internal Storage | 1.2 TB maximum hot plug SCSI (with optional hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | None ship standard (Optional 1.44 MB Diskette Drive) | |
| Form Factor | Tower (5U) (Tower to Rack Enabling Option Kit available) | |
|
|
||
| ML310T02 3.2/800-1M
HP-SATA/SAS 376852-001 |
Processor(s) | (1) Intel Pentium 3.20 GHz (standard) |
| Cache Memory | 1MB Level 2 cache | |
| Memory | 512 MB (Standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7761 PCI 10/100/1000T Gigabit network adapter | |
| Storage Controller | Four port Integrated SATA Controller | |
| Hard Drives | None ship standard (up to 4
hot plug SATA or SAS drives) NOTE: See the "Storage" section of these QuickSpecs for information on controllers and cables required to support SATA and SAS drive configurations |
|
| Internal Storage | 2.0 TB maximum hot plug SATA (with optional hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | None ship standard (Optional 1.44 MB Diskette Drive) | |
| Form Factor | Tower (5U) (Tower to Rack Enabling Option Kit available) | |
|
|
||
| ML310T02 3.2/800-1M
NHP SCSI 378279-002 |
Processor(s) | (1) Intel Pentium 3.20 GHz (standard) |
| Cache Memory | 1MB Level 2 cache | |
| Memory | 512 MB (Standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7761 PCI 10/100/1000T Gigabit network adapter | |
| Storage Controller | Single Channel Ultra320 SCSI controller in PCI slot | |
| Hard Drives | (1) 36.4 GB Ultra320 SCSI | |
| Internal Storage | 320 GB maximum (with optional hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | None ship standard (Optional 1.44 MB Diskette Drive) | |
| Form Factor | Tower (5U) (Tower to Rack Enabling Option Kit available) | |
|
|
||
| ML310T02 3.2/800-1M
NHP SATA80 381832-002 |
Processor(s) | (1) Intel Pentium 3.20 GHz (standard) |
| Cache Memory | 1MB Level 2 cache | |
| Memory | 512 MB (Standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7761 PCI 10/100/1000T Gigabit network adapter | |
| Storage Controller | Four port Integrated SATA Controller | |
| Hard Drives | (1) 80GB Non hot plug SATA drive | |
| Internal Storage | 320 GB maximum non hot plug
SATA (with optional hard drives) NOTE: See the "Storage" section of these QuickSpecs for information on controllers and cables required to support SATA drive configurations |
|
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | None ship standard (Optional 1.44 MB Diskette Drive) | |
| Form Factor | Tower (5U) (Tower to Rack Enabling Option Kit available) |
|
|
Configuration Information - Factory Integrated Models
| NOTE:
All configure-to-order servers must start with a CTO Chassis. Use the following
section to order a server customized to your requirements with options integrated
at the factory. The options you select in steps 2 and 3 will be integrated
with the base configuration you select in step 1. Additional options selected
in Step 4 will also be integrated when applicable. NOTE: Standard models of this product offering (see previous section of this document) do not support HP Factory Express Server Configuration Level 1. |
||
| Step 1: Base Configuration | ||
| Models | HP ProLiant ML310 Tower CTO Chassis NHP SCSI |
381850-405
|
| HP ProLiant ML310 Tower CTO Chassis NHP SATA |
381851-405
|
|
| HP ProLiant ML310 Tower CTO Chassis HP-SCSI |
378559-405
|
|
| HP ProLiant ML310 Tower CTO Chassis HP-SATA/SAS |
378560-405
|
|
| Factory Integrated Models ship with: | ||
| Embedded NC7761 PCI 10/100/1000T Gigabit network adapter | ||
| Integrated four Channel SATA Controller (included with 381851-405 and 378560-405 ONLY) | ||
| 350 Watts, PFC (Power Factor Correcting) | ||
| Keyboard | ||
| Mouse | ||
| Tower 5U Form Factor | ||
|
|
||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted | ||
| Processors | Celeron Processor 2.80-GHz/533 MHz Front Side Bus, FIO |
383872-L22 |
| Pentium Processor 3.00-GHz/800 MHz Front Side Bus, FIO |
390813-L22 | |
| Pentium Processor 3.20-GHz/ 800 MHz Front Side Bus, 1MB FIO |
383871-L22 | |
| Pentium Processor 3.20-GHz/ 800 MHz Front Side Bus, 2MB FIO |
383870-L22 | |
| Pentium Processor 3.40-GHz/ 800 MHz Front Side Bus, 1MB FIO |
383869-L22 | |
| Pentium Processor 3.40-GHz/ 800 MHz Front Side Bus, 2MB FIO |
383868-L22 | |
| Base
Memory | 256 MB Advanced ECC
PC3200 DDR SDRAM DIMM Kit (1 x 256 MB) |
354557-B21 |
| 512
MB Advanced ECC PC3200 DDR SDRAM DIMM Kit (1 x 512 MB) |
354560-B21 | |
| 1024 MB Advanced ECC PC3200 DDR SDRAM DIMM Kit (1 x 1024 MB) |
354563-B21 | |
| Optical Drive | CD-RW/DVD-ROM Combo Drive Option Kit | 331346-B21 |
| HP ProLiant 48X CD w/SCREWS |
337863-B21 | |
| 16X DVD-ROM Drive Option Kit (Carbon) |
217053-B21 | |
| Base Hard Drives | Non-Hot
Plug U320 SCSI Drives NOTE: For use in Non-Hot Plug SCSI base configurations P/N 381850-405 or 381805-B21. | |
| HP 36GB U320 15K NHP HDD | 357012-B21 | |
| HP 72GB U320 10K NHP HDD |
332751-B21 | |
| Hot
Plug U320 SCSI Drives NOTE: For use in Hot Plug SCSI base configurations P/N 378559-405 or 378559-B21. | ||
| HP 72GB U320 10K Universal HDD | 286714-B22
| |
| HP 146GB U320
10K Universal HDD |
286716-B22 | |
| HP
36GB U320 15K Universal HDD |
286776-B22 | |
| HP
72GB U320 15K Universal HDD |
286778-B22 | |
| Non-Hot
Plug SATA Drives NOTE: For use in Non-Hot Plug SATA base configurations P/N 381851-405 or 381851-B21. | ||
| HP 80GB 1.5G SATA 7.2K NHP 3.5"
HDD |
383410-B21 | |
| HP 160GB 1.5G SATA 7.2K NHP 3.5" HDD, FIO |
399164-B21 | |
| HP
250GB 1.5G SATA 7.2K NHP 3.5" HDD, FIO |
399165-B21 | |
| HP 500GB 1.5G SATA 7.2K 3.5" HDD |
395473-B21 | |
| Hot
Plug SATA Drives NOTE: For use in Hot Plug SATA/SAS base configurations P/N 378560-405 or 378560-B21. | ||
| HP 80GB 1.5G SATA 7.2K 3.5" HDD | 349237-B21 | |
| HP 160GB 1.5G SATA 7.2K 3.5" HDD | 349238-B21 | |
| HP 250GB 1.5G SATA 7.2K 3.5" HDD | 349239-B21 | |
| Hot Plug SAS 3.5" Drives NOTE: for use in Hot Plug SATA/SAS base configurations P/N 378560-405 or 378560-B21. | ||
| HP 36GB 3G SAS 15K 3.5" HDD | 375868-B21 | |
| HP 72GB 3G SAS 15K 3.5"
HDD | 375870-B21 | |
| HP 146GB 3G SAS 15K 3.5" HDD | 375872-B21 | |
| | ||
| Step 3: Choose Additional Factory Integratable Options | ||
| Controllers | Smart Array 641 Controller |
291966-B21
|
| Smart Array 642 Controller |
291967-B21
|
|
| 64-Bit/133MHz Dual Channel Ultra320
SCSI Adapter |
268351-B21
|
|
| 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
|
|
|
||
| Step 4: Choose Additional Options for Factory Integration |
| NOTE: For additional options, please refer to the "Options" section below. |
|
|
Options
| ProLiant
Essentials Value Pack Software |
ProLiant Essentials Intelligent Networking Pack | |
| ProLiant Essentials
Intelligent Networking Pack, Single Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372906-B21 |
|
| NOTE: For additional ProLiant Intelligent Networking Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12062_na/12062_na.HTML | ||
| ProLiant Essentials Performance Management Pack | ||
| ProLiant Essentials
Performance Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key, HP Management CD and documentation. NOTE: The most recent version of the software can always be downloaded at http://www.hp.com/products/pmp. |
306696-B21 |
|
| NOTE: For additional ProLiant Intelligent Networking Pack - Windows License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12062_na/12062_na.HTML | ||
| ProLiant Essentials Intelligent Networking Pack - Linux Edition, Single Server License |
397004-B21
|
|
| NOTE:
For additional ProLiant Intelligent Networking Pack - Linux License Kits
please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12327_na/12327_na.HTML |
||
| ProLiant Essentials Rapid Deployment Pack Windows Edition and Linux Edition Release | ||
| Rapid Deployment
Pack, Single-Server License NOTE: This license allows 1 server to be deployed and managed via RDP. |
267196-B21 |
|
| NOTE:
For additional ProLiant Essentials Rapid Deployment Pack License Kits please
see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.HTML http://h18000.www1.hp.com/products/quickspecs/11713_na/11713_na.HTML |
||
| ProLiant Essentials Virtualization Management Software | ||
| ProLiant Essentials
Virtual Machine Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372214-B21 |
|
| ProLiant
Essentials Server Migration Pack, Single-Migration License NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation. NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005. |
375345-B21
|
|
| NOTE: For additional ProLiant Essentials Virtualization Management Software License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_na/12328_na.HTML | ||
| ProLiant Essentials Vulnerability and Patch Management Pack | ||
| ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
371645-B21
|
|
| NOTE: For additional ProLiant Vulnerability and Patch Management Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_na/12111_na.HTML | ||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. |
||
|
|
||
|
Memory |
1024 MB Advanced ECC PC3200 DDR
SDRAM DIMM (1 x 1024 MB) |
354563-B21
|
| 512 MB Advanced ECC PC3200 DDR
SDRAM DIMM (1 x 512 MB) |
354560-B21
|
|
| 256 MB Advanced ECC PC3200 DDR SDRAM DIMM (1 x 256 MB) |
354557-B21
|
|
|
|
||
| Optical
Drives
|
16X DVD-ROM Drive Option Kit (Carbon) | 217053-B21 |
| CD-RW/DVD-ROM Combo Drive Option
Kit NOTE: The DVD-ROM drive is supported in the CD-ROM bay and in the removable media bay. If placed in the removable media bay, it requires the 2-Device IDE cable (PN 305381-B21). |
331346-B21
|
|
| HP DVD+R/RW 16X Half Height |
383974-B21
|
|
|
|
||
| Diskette Drives | 1.44MB Floppy Drive Option Kit |
379257-B21
|
|
|
||
| Serial Port Kit | HP ProLiant 2nd Serial port option kit |
390390-B21
|
|
|
||
| Hard Drives | Ultra320 - Universal Hot Plug (SCSI Hot Plug Models Only) | |
| HP 300GB U320 10K Universal HDD |
350964-B22 | |
| HP 146GB U320 10K Universal HDD |
286716-B22 | |
| HP 72GB U320 10K Universal HDD | 286714-B22 | |
| HP 146GB U320 15K Universal HDD |
347708-B22 | |
| HP 72GB U320 15K Universal HDD | 286778-B22 | |
| HP 36GB U320 15K Universal HDD |
286776-B22 | |
| Ultra320 - Non-Hot Plug (SCSI Non Hot Plug Models Only) | ||
| HP 146GB U320 10K NHP HDD | 356990-B21 | |
| HP 72GB U320 10K NHP HDD | 332751-B21 | |
| HP 36GB U320 15K NHP HDD | 357012-B21 | |
| NOTE: Please
see the Wide Ultra320 Universal Hot Plug QuickSpecs for additional technical information
on the hard drives Support details, please see the following: | ||
| Serial-Attached SCSI (SAS) Hot Plug Hard Drive (SATA/SAS Hot Plug Models Only) | ||
| HP 146GB 3G SAS 15K 3.5" HDD | 375872-B21 | |
| HP 72GB 3G SAS 15K 3.5" HDD | 375870-B21 | |
| HP 36GB 3G SAS 15K 3.5" HDD | 375868-B21 | |
| Serial-ATA (SATA) Hot Plug Hard Drive (SATA/SAS Hot Plug Models Only) | ||
| HP 250GB 1.5G SATA 7.2K 3.5" HDD | 349239-B21 | |
| HP 160GB 1.5G SATA 7.2K 3.5" HDD | 349238-B21 | |
| HP 80GB 1.5G SATA 7.2K 3.5" HDD | 349237-B21 | |
| Serial-ATA (SATA) Non Hot Plug Hard Drive (SATA Non Hot Plug Models Only) | ||
| HP 80GB 1.5G SATA 7.2K NHP 3.5" HDD |
383410-B21 | |
| NOTE:
Please see the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration, and
operating temperature: http://h18000.www1.hp.com/products/quickspecs/11940_na/11940_na.HTML | ||
| | ||
| Hard Drive Cables | HP 4-port SATA/SAS cable (target fan cable) |
389653-B21
|
| NOTE: This cable is required when the HP 6-port SATA RAID controller is installed on hot plug SATA/SAS models of the ML310 G2. See the "Storage" section of these QuickSpecs for information on controllers and cables required to support SATA drive configurations. | ||
| HP 2-port SATA Cable |
379093-B21
|
|
| NOTE: This cable is required when the HP 6-port SATA RAID controller is installed on non-hot plug SATA/SAS models of the ML310 G2. See the "Storage" section of these QuickSpecs for information on controllers and cables required to support SATA drive configurations. | ||
|
|
||
| Storage Controllers | SCSI Controllers | |
| NOTE: The following Storage Controllers are qualified for SCSI drives only. They do not support SATA or SAS Drives. | ||
| Smart Array 6402/128 Controller |
273915-B21 | |
|
Smart Array 6404/256 Controller |
273914-B21 | |
|
Smart Array 641 Controller |
291966-B21 | |
|
Smart Array 642 Controller |
291967-B21 | |
| 128MB
Battery-Backed Cache Enabler NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array 642 Controller. | 351580-B21 | |
| Ultra320 Expansion Module for SA-6402 | 273911-B21 | |
| 64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter |
268351-B21 | |
| 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21 | |
| NOTE:
Please see the following Controller or SCSI Adapter QuickSpecs for Technical
Specifications such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported,
SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache, RAID
support, and additional information: http://h18000.www1.hp.com/products/quickspecs/12067_na/12067_na.HTML (Smart Array 641) http://h18000.www1.hp.com/products/quickspecs/12069_na/12069_na.HTML (Smart Array 642) http://h18000.www1.hp.com/products/quickspecs/10429_na/10429_na.HTML (Dual Channel SCSI Adapter) http://h18000.www1.hp.com/products/quickspecs/11943_na/11943_na.HTML (Single Channel SCSI HBA) | ||
| SAS Controllers | ||
| Smart Array P600 Controller NOTE: Serial SCSI/ATA. |
337972-B21 | |
| 512MB DDR BBWC Upgrade | 372538-B21 | |
| NOTE: Please
see the following Controller QuickSpecs for Technical Specifications such as PCI
Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak Data Transfer
Rate, Channels, SCSI Ports, Drives supported, Cache, RAID support, and additional
information: http://h18000.www1.hp.com/products/quickspecs/12247_na/12247_na.HTML (Smart Array P600 Controller) | ||
| SAS HBA | ||
| HP 8 Internal Port SAS HBA with RAID | 347786-B21 | |
| NOTE: Please
see the HBA QuickSpecs for additional information: http://h18000.www.1.hp.com/products/quickspecs/12332_div/12332_div.HTML | ||
| SATA Controller | ||
| HP 6-port SATA RAID Controller NOTE: See the "Storage" section of these QuickSpecs for information on controllers and cables required to support SATA drive configurations |
372953-B21 | |
|
| ||
| Communications | HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter | 367132-B21 | ||
| HP NC310F PCI-X 1000SX Gigabit Server Adapter | 368169-B21 | |||
| HP NC320T PCI Express 1000T Gigabit Server Adapter | 367047-B21 | |||
| HP NC1020 PCI 1000T Gigabit Server Adapter | 353377-B21 | |||
| HP NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter | 313881-B21 | |||
| HP NC7771 PCI-X 1000T Gigabit Server Adapter | 290563-B21 | |||
| NOTE: NC61XX, NC71XX, NC77XX, or NC1020 network adapter (NIC) can be used for redundancy with the embedded NC7761 NIC. When either the embedded NC7761 or the NC1020 is teamed with other HP NICs, Jumbo Frames and LSO features are automatically disabled. | ||||
| | ||||
|
Management Options |
Remote Insight Lights-Out Edition II |
227251-001 |
|
|
||
|
Tape Drives |
| ||||||||||||||||||||||||||||||||||||||||||
|
| |||||||||||||||||||||||||||||||||||||||||||
| Tape
Autoloaders | DAT Autoloader | |
| HP StorageWorks DAT 72x6 Autoloader (Internal) | Q1566A | |
| HP StorageWorks DAT 72x6 Autoloader (External) | Q1567A | |
| NOTE: Please
see the DAT 72x6 Tape Autoloader QuickSpecs for additional options such as host
bus adapters, controllers and media: http://h18006.www1.hp.com/products/quickspecs/11905_na/11905_na.html | ||
| HP StorageWorks 1/8 Tape Autoloader | ||
| HP StorageWorks 1/8 Ultrium 960 Tape Autoloader | AF204A | |
| HP StorageWorks 1/8 Ultrium 448 Tape Autoloader | AF203A | |
| HP StorageWorks 1/8 Ultrium 232 Tape Autoloader | AF202A | |
| 1/8 Tape Autoloader Rackmount
Kit NOTE: Required to install the unit in a standard 19-inch rack; includes rails and rackmount instructions | C9268R | |
| NOTE: Please reference the 1/8 Tape Autoloader QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs | ||
| | ||
| Tape Libraries | HP StorageWorks MSL2024 Tape Library | |
| HP StorageWorks MSL2024 1 Ultrium 960 Drive Library | AG115A | |
| HP StorageWorks MSL2024 1 Ultrium 448 Drive Library | AG116A | |
| HP StorageWorks MSL2024 2 Ultrium 448 Drive Library | AG117A | |
| HP StorageWorks MSL6000 Tape Library | ||
| Ultrium 960 technology | ||
| HP StorageWorks MSL6030 1 Ultrium 960 Dr LVDS Library | AD606A | |
| HP StorageWorks MSL6030 1 Ultrium 960 Dr FC Library | AD608A | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr LVDS Library | AD607A | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr FC Library | AD609A | |
| Ultrium 460 technology | ||
| HP StorageWorks MSL6030 1 Ultrium 460 Dr LVDS Library | AD598A | |
| HP StorageWorks MSL6030 1 Ultrium 460 Dr FC Library | AD600A | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr LVDS Library | AD599A | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr FC Library | AD601A | |
| NOTE: Please reference the MSL2024 and MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. | ||
|
|
||
| Magneto-Optical Jukeboxes | HP StorageWorks 9.1 GB Optical Jukeboxes | |
| 600mx, 4 drive, 64 slot jukebox |
C1160M
|
|
| 1200mx, 4 drive, up to 128 slots |
C1104M
|
|
| 2200mx, 6 drive, up to 238 slots |
C1107M
|
|
| NOTE: Please see the HP StorageWorks
Magneto-Optical Products data sheet for a complete listing of available
jukeboxes at: http://www.hp.com/products1/storage/products/archivalprod/brochures/ MO_family_pb.pdf NOTE: Please reference the Magneto-Optical Jukebox data sheets at http://www.hp.com/go/optical for additional information needed to create a complete solution. |
||
|
|
||
| Ultra Density Optical Jukeboxes | 1900ux, 4 drive, 64 slot jukebox | AA966A |
| 3800ux, 4 drive, 128 slot jukebox | AA969A | |
| 7100ux, 6 drive, 238 slot jukebox | AA971A | |
| NOTE: Please see
the HP StorageWorks Ultra Density Optical Jukeboxes QuickSpecs for a complete
listing of available jukeboxes at: http://h18006.www1.hp.com/products/quickspecs/11944_na/11944_na.html NOTE: Please reference the Ultra Density Optical Jukebox QuickSpecs at http://www.hp.com/go/optical for additional information needed to create a complete solution |
||
|
|
||
| HP StorageWorks Modular Smart Array 30 | HP
StorageWorks Modular Smart Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies | 302969-B21 |
| HP StorageWorks Modular Smart
Array 30 DB NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies | 302970-B21 | |
| NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 Hot Plug Hard Drives. | ||
| | ||
|
Uninterruptible Power Systems – Tower Supply |
HP T500 UPS 120 V |
361475-001
|
| HP UPS Model T700 (700VA, 500 Watt), Low Voltage |
204015-001
|
|
| HP T750 UPS |
378439-D71
|
|
| HP UPS Model T1000 XR (1000VA, 700 Watt), Low Voltage |
204155-001
|
|
| HP UPS Model T1500 XR (1440VA, 1050 Watt), Low Voltage |
204155-002
|
|
|
|
||
|
Uninterruptible Power Systems Rack |
HP UPS R5500 XR, (5000VA, 4500 Watt), High Voltage | 326529-D71 | |
| HP UPS R1500 XR (100 to 127) |
204404-001
|
||
| HP UPS R3000 XR (120V) |
192186-001
|
||
| HP UPS R3000 XR (208V) |
192186-002
|
||
| HP UPS R5500 XR, (5000VA, 4500 Watt), High Voltage |
326529-D71
|
||
| UPS R12000 XR N+ x (200-240V) (hardwired) |
207552-B22
|
||
| NOTE: The UPS R12000 XR has a hardwired input and output connection. | |||
|
|
|||
|
Modular PDUs 1U/0U |
HP Modular Power Distribution
Units (mPDU), Low Volt Model, 24A (100-127 VAC) NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of the UPS R3000 XR. |
252663-D71 |
| HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC) | 252663-D72 | |
| HP Modular Power Distribution
Units (mPDU), High Volt Model, 40A (200-240 VAC) NOTE: This mPDU (252663-B21), 40A model has a hardwired input. |
252663-B21 | |
| HP Modular Power Distribution
Units (mPDU), High Volt Model, 16A (200-240 VAC) NOTE: This PDU has a detachable input power cord and allows for adaptability to country specific power requirements. This model may also be used with the high volt UPSs R3000 XR and R6000. Need to order cable PN 340653-001. |
252663-B24 | |
| NOTE:Please see
the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables and country specific
power cords: http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.HTML |
||
|
|
||
|
Rack Enabling Kit |
ProLiant ML310/ML330 G2 Rack Enabling Kit |
238547-B22
|
|
| NOTE: Support for racks with round or square mounting holes (including all Compaq and HP Rack System /E and HP Systems), with an adjustment range of 24" 36". | |||
|
|
|||
| Other | Internal to External SCSI Cable Option Kit (HD68) |
159547-B22
|
| Internal to External SCSI Cable Option Kit (VHDCI) |
333370-B21
|
|
| Telco Rack Option Kit |
251243-B21
|
|
| NOTE: Support for all 2-post Telco racks requires the use of the standard four post rack kit and an additional option kit from HP. | ||
|
|
||
| USB Options | USB Optical Scroll Mouse (Carbonite) | DD441B |
| USB 1.44-MB External Diskette Drive (Carbonite) |
DC141B
|
|
| | ||
| HP Rack 5000 Series (Graphite Metallic) | HP 5642 Rack-Unassembled |
358254-B21
|
|
|
||
| Rack Options for Rack 5000 Series | Stabilizer Kit for 5642 Rack (Graphite
Carbon) NOTE: The stabilizing kit is used to prevent rack from tipping over. |
374493-B21
|
| Baying Kit for 5642 Rack (Graphite
Carbon) NOTE: The baying kit is used to join two or more HP 5642 racks. |
374499-B21
|
|
|
|
||
|
HP Rack 10000 G2 Series (Carbon/Graphite Metallic) | 10642 G2 (42U) Rack Cabinet - Pallet | AF001A |
| 10642 G2 (42U) Rack Cabinet - Shock Pallet | AF002A | |
| 10642 G2 (42U) Rack Cabinet - Crated | AF003A | |
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet | AF004A | |
| 10642 G2 (42U) Rack Cabinet, without door - Shock Pallet | AF005A | |
| 10642 G2 (42U) Rack Cabinet - with Extension, without door - Shock Pallet | AF006A | |
| 10636 G2 (36U) Rack Cabinet - Pallet | AF011A | |
| 10636 G2 (36U) Rack Cabinet - Shock Pallet | AF012A | |
| 10636 G2 (36U) Rack Cabinet - Crated | AF013A | |
| 10636 G2 (36U) Rack Cabinet , with Extension - Shock Pallet | AF014A | |
| 10636 G2 (36U) Rack Cabinet, without door - Shock Pallet | AF015A | |
| 10636 G2 (36U) Rack Cabinet, with Extension, without door - Shock Pallet | AF016A | |
| NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed. | ||
| NOTE: Please
see the Rack 10000 G2 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.HTML | ||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
| Rack Options for Rack 10000 G2 Series | HP 10642 G2 Front Door | AF009A |
| HP 10636 G2 Front Door | AF019A | |
| 10642 G2 (42U) Side Panels (set of two) (Graphite Metallic) | AF054A | |
| 10636 G2 (36U) Side Panels (set of two) (Graphite Metallic) | AF056A | |
| 10636 G2 Rear Extension Kit | AF060A | |
| 600mm G2 Stabilizer Option Kit (Graphite) | AF062A | |
| 600mm G2, Heavy Duty Stabilizer Option Kit (Graphite) | AF064A | |
| 800mm G2 Stabilizer Option Kit (Graphite) | AF066A | |
| 800mm G2, Heavy Duty Stabilizer
Option Kit (Graphite) NOTE: Supports 10000 G2 Series only. | AF068A | |
| HP 10000 G2 Rack Grounding Kit | AF074A | |
| 600W 10K G2 Rack Tie Down | AF076A | |
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
|
HP Rack 10000 Series (Graphite Metallic) | HP Rack S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22 |
| HP Rack 10842 (42U) Rack Cabinet - Pallet |
257415-B21 | |
| HP Rack 10842 (42U) Rack Cabinet - Shock Pallet |
257415-B22 | |
| HP Rack 10647 (47U) Pallet |
245160-B21 | |
| HP Rack 10647 (47U) Crated |
245160-B23 | |
| HP Rack 10642 (42U) Pallet |
245161-B21 | |
| HP Rack 10642 (42U) Shock Pallet |
245161-B22 | |
| HP Rack 10642 (42U) Crated |
245161-B23 | |
| HP Rack 10636 (36U) Pallet |
245162-B21 | |
| HP Rack 10636 (36U) Shock Pallet |
245162-B22 | |
| HP Rack 10636 (36U) Crated |
245162-B23 | |
| HP Rack 10622 (22U) Pallet |
245163-B21 | |
| HP Rack 10622 (22U) Shock Pallet |
245163-B22 | |
| HP Rack 10622 (22U) Crated |
245163-B23 | |
| NOTE:
-B21 (pallet) used to ship empty racks shipped on a truck -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels) -B23 (crated) used for air shipments of empty racks | ||
| NOTE: Please
see the Rack 10000 QuickSpecs for Technical Specifications such as height, width,
depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.HTML |
||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/racks/index.html. | ||
| | ||
|
Rack Options for Rack 10000 Series | HP Rack Light Kit (Neon) | 361589-B21 |
| HP Rack Plinth Kit (Carbon) |
251960-B21 | |
| 42U Side Panel - Graphite Metallic |
246099-B21 | |
| 36U Side Panel - Graphite Metallic |
246102-B21 | |
| 47U Side Panel - Graphite Metallic |
255486-B21 | |
| TFT7210R
Rack Mounted 17" Monitor NOTE: For a complete list of Monitors please view the following URL: http://www.hp.com/go/kvm. |
348373-B21 | |
| TFT5600
Rack Keyboard Monitor NOTE: For a complete list of Monitors please view the following URL: http://www.hp.com/go/kvm. |
221546-001 | |
| 1U Rack Keyboard & Drawer (Carbon) |
257054-001 | |
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. | ||
| | ||
| HP KVM Switch Options | IP Console Switch Box (KVM/IP), 3 x 1 x 16 |
262586-B21
|
| IP Console Switch Box (KVM/IP), 1 x 1 x 16 |
262585-B21
|
|
| Server Console Switch (KVM), 0 x 1 x 8 port |
336044-B21
|
|
| Server Console Switch (KVM), 0 x 2 x 16 port |
336045-B21
|
|
| PS/2 Interface Adapter, 1 pack |
262588-B21
|
|
| PS/2 Interface Adapter, 8 pack |
262587-B21
|
|
| USB Interface Adapter, 1 pack |
336047-B21
|
|
| Serial Interface adapter - 1 Pack with power supply |
373035-B21
|
|
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x 4 USB/PS2 KVM Switch, TT |
371301-D71
|
|
| HP PS2 KVM Cable with audio, 6', 2-pack |
371730-B21
|
|
| HP USB KVM Cable with audio, 6', 2-pack |
371729-B21
|
|
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| HP Serial Console Server Options | HP 16 Port Serial Console Server |
AF101A
|
| HP 48 Port Serial Console Server |
AF102A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack |
AF103A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack |
AF110A
|
|
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| Service and Support Offerings (HP Care Pack Services) |
|
||||||||||
|
|||||||||||
|
|||||||||||
|
|||||||||||
|
|
|
Memory
|
HP ProLiant ML310 G2 All Models |
|
Standard Memory - Pentium 4 Models |
|
|
|
These systems support PC3200
DDR memory and come standard with a single PC3200 The system board provides four DIMM sockets:
DIMMs do not need to be installed in pairs although
installation of pairs (an equal DIMM for each channel) provides the best
performance. The BIOS will detect the DIMM population and set the system
accordingly as follows:
These systems require DIMMs with the following parameters:
The first DIMM should be installed in Socket 1. A DIMM should not be installed in Socket 2 without a DIMM in Socket. Likewise a DIMM should not be installed in Socket 4 without a DIMM in Socket 3. A DIMM need not be installed in Socket 2 in order to install a DIMM in Socket 3. The table below shows some of the suggested memory configurations for these systems. NOTE: Table below does not list all possible configurations. Balanced-capacity, dual-channel loading yields best performance. |
|
Channel A |
Channel B |
Total |
Mode |
||
| Socket 1 | Socket 2 |
Socket 3 |
Socket 4 |
||
|
256 MB |
none
|
none
|
none
|
256 MB
|
Single-channel
|
|
256 MB
|
none
|
256 MB
|
none
|
512 MB
|
Dual-channel interleaved
|
|
512 MB
|
none
|
none
|
none
|
512 MB
|
Single-channel
|
|
512 MB
|
none
|
512 MB
|
none
|
1 GB
|
Dual-channel interleaved
|
|
1 GB
|
none
|
none
|
none
|
1 GB
|
Single-channel
|
|
1 GB
|
none
|
1 GB
|
none
|
2 GB
|
Dual-channel interleaved
|
|
1 GB
|
1-GB
|
1 GB
|
none
|
3 GB
|
Dual-channel asymmetric
|
|
1 GB
|
1-GB
|
1 GB
|
1 GB
|
4 GB
|
Dual-channel interleaved
|
|
|
Storage
![]() | A,
| 48x IDE (ATAPI) CD-ROM |
| B, C | Removable Media Bays (1.6" each) | |
| 0, 1, 2, 3 | Four Non-Hot Plug Drive Bays, or Four Hot Plug Drive Bays | |
| Drive Support | |||
|
Quantity |
Position |
| |
|
Removable Media | |||
| 1.44-MB Diskette Drive | Up to 1 | A, B, or C | Integrated |
| IDE (ATAPI) CD-ROM Drive | Up to 2 | A, B, or C | Integrated IDE (ATAPI) |
| DVD-ROM Drive Option Kit | Up to 2 | A, B, or C | Integrated IDE (ATAPI) |
| | |||
|
Hard Drives | |||
| Ultra320 SCSI - Non-Hot Plug (Non-Hot Plug SCSI models only) | |||
| Quantity |
Position |
| |
36.4GB
U320 15K | Up to 4 | 0,1, 2, or 3 |
Single Channel Ultra320 SCSI Adapter (SCSI Models) |
| | |||
| Ultra320 SCSI -Hot Plug (Hot Plug SCSI models only) | |||
| Quantity |
Position |
| |
|
300GB U320 10K | Up to 4 | 0,1, 2, or 3 | Single
Channel Ultra320 SCSI Adapter (SCSI Models) Smart Array 6404/256 Controller Smart Array 6404/256 Controller Smart Array 641 Controller Smart Array 642 Controller 64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter |
| | |||
| Hot Plug SAS - (Hot Plug SATA/SAS Models Only) | |||
| Quantity |
Position |
| |
|
36GB 3G SAS 15K | Up to 4 | 0, 1, 2, 3 |
Smart Array P600 Controller |
| NOTE: Use of SAS hard drives in SATA/SAS models requires installation of the Smart Array P600. | |||
| | |||
| Hot Plug Serial ATA - (Hot Plug SATA/SAS Models Only) | |||
|
Quantity |
Position |
| |
| 80GB
1.5G SATA 7.2K 160GB 1.5G SATA 7.2K 250GB 1.5G SATA 7.2K | Up
to 4* | 0,
1 | Integrated four port SATA Controller with RAID 0/1 |
| Up to 2* | 0, 1, 2, 3 | Integrated four port SATA Controller with RAID 0/1 | |
| Up to 4 | 0, 1, 2, 3 | HP 6-port SATA RAID controller | |
| *NOTE:
A maximum of two hard drives are supported when integrated RAID is enabled. Use
of hot plug SATA hard drives in positions 2 and/or 3 requires either a non-RAID
configuration or installation of the HP 6-port SATA RAID controller (P/N 372953-B21)
and the HP 4-port SATA/SAS target fan cable (P/N 389653-B21). NOTE: Hot plug capability and drive LED status support requires installation of the HP 6-port SATA RAID controller. | |||
|
| |||
| Non-Hot Plug SATA - (Non-Hot Plug SATA models only) | |||
| Quantity |
Position |
| |
|
80GB 1.5G SATA 7.2K 160GB 1.5G SATA 7.2K 250GB 1.5G SATA 7.2K | Up
to 2* | 0, 1 | Integrated four port SATA Controller |
| Up to 4* | 0, 1, 2, 3 | Integrated four port SATA Controller with RAID 0/1 | |
| Up to 4* | 0, 1, 2, 3 | HP 6-port SATA RAID controller | |
| *NOTE: A maximum
of two hard drives are supported when integrated RAID is enabled. Use of non-hot
plug SATA hard drives in positions 2 and/or 3 requires either a non-RAID configuration
or installation of the HP 6-port SATA RAID controller (P/N 372953-B21) and two
of the HP 2-port SATA/SAS cables (P/N 379093-B21). NOTE: Drive LED status support requires installation of the HP 6-port SATA RAID controller. | |||
| | |||
|
External Storage |
|||
|
Quantity |
Position |
|
|
| Modular Smart Array 30 Family | External | Smart Array 642 Controller | |
|
|
|||
|
Maximum Storage Capacity - SATA Models (SCSI Attached (Enclosure)) | |
|
Internal | 1.0TB (4 x 250GB) |
| External | 29.40TB (14 x 300GB) x 7 (Requires additional SCSI controllers in slots) |
| Total | 30.40TB |
|
Maximum Storage Capacity - SCSI Models (SCSI Attached (Enclosure)) | |
|
Internal | 1.2TB (4 x 300GB hot-plug hard drives) |
| External | 29.40TB (14 x 300GB) x 7 |
| Total | 30.60TB |
| | |
| Tape Drives, Tape Autoloaders & Tape Libraries | |||
|
NOTE: For an up-to-date listing of the latest
O/S Support details for each of the Tape Drives listed below, please see the following: NOTE:
For an up-to-date listing of the latest O/S Support details for each of the
Tape Autoloaders and Tape Libraries listed below, please see the following: NOTE: For complete listing of tape drive offerings see http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html | |||
| Quantity Supported | Position Supported |
| |
|
HP StorageWorks Tape Drives, USB Internal | 1 | B,C | Embedded USB port |
| HP StorageWorks Tape Drives,
USB External | 1 per USB port | External | USB port |
| HP StorageWorks Tape Drives,
Internal Ultrium 232 Ultrium 448 Ultrium 460 Ultrium 960 DAT 40 DAT 72 DLT VS80 DLT VS160 SDLT 320 SDLT 600 | 1 | B,C | 64-Bit/133MHz Dual Channel
Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
| HP StorageWorks Tape Drives,
Internal Ultrium 232 Ultrium 448 Ultrium 460 Ultrium 960 DAT 40 DAT 72 DLT VS80 DLT VS160 SDLT 320 SDLT 600 | 1 | B,C | 64-Bit/133MHz Dual Channel
Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
| HP StorageWorks Tape Drives,
External Ultrium 960 SDLT 600 | 1 per SCSI Channel | External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
| HP StorageWorks Autoloaders,
Internal DAT 72x6 Tape Autoloader | 1 | B,C | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
| HP StorageWorks Autoloaders,
External DAT 72x6 Tape Autoloader 1/8 Tape Autoloader | 1 autoloader per SCSI channel | External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
| HP StorageWorks Tape Libraries,
External MSL2024 (Ultrium 960-based) MSL2024 (Ultrium 448-based) MSL6000 (Ultrium 960-based) MSL6000 (SDLT 600-based) MSL6000 (Ultrium 460-based) MSL5026S2 (SDLT 320-based) MSL5052S2 (SDLT 320-based) | Please reference the MSL Tape Library QuickSpecs to determine configuration requirements | External | Please
consult the EBS connectivity matrix at http://www.hp.com/go/ebs
for detailed connectivity information. |
|
|
Technical Specifications
| System Unit | Dimensions (HxWxD) | 17.0 x 7-7/8 x 22 in (43.0 x 20.0 x 55.0 cm) | |
| Weight(approximate) | 37 lb (16.8 kg) | ||
| Input Requirements (per power supply) | Range Line Voltage | 100-127V and 200-240V | |
| Normal Line Voltage | 115 to 230 VAC | ||
| Line Frequency | 50 to 60 Hz | ||
| Rated Input Current | < 6A RMS at 90VAC with maximum load | ||
| BTU Rating | 1,560 BTU | ||
| SCSI
Connectors (SCSI Models only) | One internal HD68 connectors | ||
| NOTE: Support for either one internal or one external SCSI channel is available. This is achieved using an internal to external SCSI cable option kit (PN 159547-B22) and SCSI knockout bracket. | |||
| Power Supply Output Power | Rated Steady-State Power | 350W | |
| Maximum Peak Power | 370W | ||
| Temperature Range | Operating | 50° to 93° F (10° to 35° C) | |
| Shipping | -40° to 150° F (-40° to 66° C) | ||
| Relative
Humidity (non-condensing) | Operating | 20% to 80% | |
| Non-operating | 5% to 90% | ||
| Acoustic Noise | Idle (Fixed Disk Drives Spinning) | ||
| L WAd
(BELS) |
5.7 | ||
| L pAm
(dBA) |
40 | ||
| Operating (Random Seeks to Fixed Disks) | |||
| L
WAd (BELS) |
5.7 | ||
| L
pAm (dBA) |
40 | ||
|
|
|||
| Non-Hot Plug Wide Ultra320 SCSI Hard Drives | 36.4 GB 15K | Capacity | 36419.2 MB | |
| 357012-B21 | Height | 1 in (2.54 cm) | ||
| Width | 4 in (10.16 cm) | |||
| Interface | Ultra320 SCSI | |||
| Transfer Rate Synchronous (Maximum) |
320 MB/s | |||
| Seek Time (typical reads, including settling) |
Single Track | 0.4 ms |
||
| Average | 3.8 ms |
|||
| Full-Stroke | 8 ms |
|||
| Rotational | 15,000 rpm | |||
| Physical Configuration | Bytes/Sector |
512 | ||
| Logical Blocks | 71,132,000 | |||
| Operating Temperature | 50° to 95° F (10° to 35° C) | |||
|
|
||||
|
Non-Hot Plug SATA/100 |
80 GB 7.2K |
Capacity | 80,000 MB | |
| 383410-B21 | Height | 1.028 in/2.611cm | ||
| Width | 4.0 in/10.16 cm | |||
| Interface | Serial ATA | |||
| Transfer Rate Synchronous (Maximum) |
1.5 Gb/s | |||
| Seek Time (typical reads, including settling) |
Single Track | 0.9 ms | ||
| Average | 9.0 ms | |||
| Full-Stroke | 17.0 ms | |||
| Rotational | 7,200 rpm | |||
| Physical Configuration | Bytes/Sector |
512 | ||
| Logical Blocks | 156,301,488 | |||
| Operating Temperature | 41° to 131° F (5° to 55° C) | |||
|
|
||||
|
48X Max IDE (ATAPI) |
Disk | Applicable Disk | CD-ROM, CD-XA, CD-DA (Mode 1, Mode 2, Form 1 and 2) |
| Photo CD (Single and Multi-session) | |||
| Mixed Mode (Audio and Data combined) | |||
| CD-R | |||
|
Capacity | 540 MB (Mode 1, 12 cm) | ||
| 650 MB (Mode 2, 12 cm) | |||
| Block Size |
Mode 1 | 2,048 bytes | |
|
Mode 2 | 2,340 bytes, 2,336 bytes | ||
|
CD-DA | 2,352 bytes | ||
| CD-XA | 2,328 bytes | ||
| Interface |
IDE (ATAPI) | ||
| Access Times (typical) |
Random | <100 ms | |
| Full-Stroke | <150 ms | ||
| Data Transfer Rate | Sustained | 3000 to 7200 KB/s (20X to 48X) | |
| Burst | 150 KBps to 7,200 KBps | ||
| Bus Rate | 16.7 MBps | ||
| Cache Buffer |
128 KB | ||
|
Start-up Time (typical) |
< 7seconds | ||
| Stop Time | < 4seconds | ||
|
Laser Parameters | Type | Semiconductor Laser GaA1As | |
| Wave Length | 780 ± 25 nm | ||
| Operating Conditions |
Temperature | 41° to 113° F (5° to 45° C) | |
|
Humidity | 10% to 80% | ||
| Dimensions |
(HxWxD, maximum) | 1.7 x 5.85 x 8.11 in (4.29 x 14.86 x 20.60 cm) | |
| Weight | 2.09 lb (0.95 kg) | ||
| | |||
|
Embedded NC7761 PCI 10/100/1000T Gigabit network adapter |
Network Interface | 10Base-T/100Base-TX/1000Base-TX | |
| Compatibility | IEEE 802.3 10Base-T | ||
| IEEE 802.3ab 1000Base-T | |||
| IEEE 802.3u 100Base-TX | |||
| Data Transfer Method | 32-bit bus-master PCI | ||
| Network Transfer Rate | 10Base-T(Half-Duplex) | 10 Mb/s | |
| 10Base-T(Full-Duplex) | 20 Mb/s | ||
| 100Base-TX(Half-Duplex) | 100 Mb/s | ||
| 100Base-TX(Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000Mb/s | ||
| Connector | RJ-45 | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP; up to 328 ft (100 m) | |
| 10/100/1000Base-TX | Category 5 UTP; up to 328 ft (100 m) | ||
|
|
|||
|
Integrated 4 Channel SATA Controller |
Drives Supported | Up to 4 SATA hard drives (1 drive/channel) | ||
| Channels | 4 | |||
| Storage Capacity | 1 TB | |||
| Maximum SATA Channel Transfer Rate | 150 MB/s per channel | |||
| SATA Protocols | SATA-1a | |||
| Internal SATA Connectors | One 4-lane connector (all four channels) | |||
|
|
||||
|
Single Channel Ultra320 SCSI Adapter |
Drives Supported | Up to 15 SCSI devices Wide | ||
| Data Transfer Method | 64-bit/100-MHz PCI bus-master | |||
| SCSI Channel Transfer Rate | 320 MB/s per channel | |||
| Maximum Transfer Rate per PCI Bus (peak) | 1033 MB/s per channel |
|||
| SCSI Protocols | Ultra320, Wide Ultra3, Wide Ultra2, Wide Ultra SCSI-3, Fast-Wide SCSI-2, and Fast SCSI-2 | |||
| Fast SCSI-2 | ||||
| Electrical Protocol | Low Voltage Differential (LVD) | |||
| SCSI Termination | Active Termination | |||
| External SCSI Connectors | None. | |||
| NOTE: To implement an external SCSI connection, install an optional controller or internal to external SCSI option kit (part number 159547-B22 for HD68 or 333370-B21 for VHDCI). | ||||
| Internal SCSI Connectors | One 68-Pin Wide Ultra SCSI-3 connectors | |||
|
|
||||
|
© Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties
for HP products and services are set forth in the express warranty statements
accompanying such products and services. Nothing herein should be construed as
constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |