Overview
|
HP ProLiant ML350 Generation 4p (G4p)
|
|||||||||||||||
| What's New |
|
The HP ProLiant ML350 G4p now supports several exciting new options:
|
|
|
| At A Glance
The HP ProLiant ML350 G4p is a traditional server
refined with essential availability features to form a versatile, dependable
backbone for expanding businesses and dedicated workgroups.
|
|
|
Standard Features
| Processor One of the following depending on Model |
Intel Xeon Processor 3.4 GHz/800-2MB L2 |
| Intel Xeon Processor 3.2 GHz/800-2MB L2 | |
| Intel Xeon Processor 3.0 GHz/800-2MB L2 | |
| NOTE: "Factory Integrated Models" are configured to order and require the selection of at least one processor. | |
|
|
|
| Cache Memory | Integrated 2MB Level 2 cache |
|
|
|
| Processor Upgradeability | Upgradeable to dual processing |
|
|
|
| Chipset |
Intel® E7520 Chipset with 800-MHz Front Side Bus |
|
|
|
| Memory Protection |
Online Spare |
| Advanced ECC | |
|
|
|
| Memory One of the following depending on model |
Type | PC2-3200 DDR2 SDRAM (400MHz) |
| Standard for Non-Array Models | 512 MB (1 x 512 MB) | |
| Standard for Array Models | 1 GB (2 x 512 MB) | |
| Maximum | 12 GB | |
| NOTE: The standard memory information above does not apply to factory integrated models. The memory configuration in factory integrated models is set according to your specifications. | ||
|
|
||
| Network Controller | Embedded NC7761 Gigabit Server Adapter |
|
|
|
| Expansion Slots |
Slot
Number |
Bus Speed
|
Maximum Card Length
|
Bus Number*
|
Device Number**
|
Hot Plug
|
PCI Voltage
|
|
1
|
PCI Express x4 (half length) |
6.6
|
16
|
1
|
no
|
N/A
|
|
|
2
|
PCI Express x8 |
12.28
|
12
|
1
|
no
|
N/A
|
|
|
3
|
64-bit/100MHz PCI-X |
12.28
|
9
|
2
|
no
|
3.3 Volt
|
|
| In HP ProLiant ML350 G4p Array Models, the Smart Array 641 is installed in Slot 3. | |||||||
|
4
|
64-bit/100MHz PCI-X |
12.28
|
9
|
1
|
no
|
3.3 Volt
|
|
|
5
|
64-bit/133MHz PCI-X |
12.28
|
6
|
1
|
no
|
3.3 Volt
|
|
|
6
|
64-bit/66MHz PCI-X |
12.28
|
2
|
2
|
no
|
3.3 Volt
|
|
| *NOTE:
Bus number listed reflects the default bus assignment. Inserting cards with
PCI bridges may alter the actual bus assignment number. **NOTE: Slots are enumerated differently based on operating system. Microsoft's operating systems enumerate from lowest to highest Device ID by bus (starting with the lowest bus). NOTE: All slots can accept universal keyed PCI cards |
|||||||
|
|
|||||||
| Storage Controller One of the following depending on model |
Integrated Dual Channel Ultra320
SCSI Adapter HP integrated 2 Port SATA controller |
| Smart Array 641 Controller (Standard in Array Models only) | |
|
|
|
| Storage | Diskette Drives | 1.44 MB Diskette Drive |
| Optical Drive | 48x IDE CD-ROM Drive | |
| Hard Drives | None included standard | |
| External Storage |
Two external SCSI port knockouts available; optional Internal-to-External
SCSI Cable Option Kit required for external connections
|
|
|
|
||
| Maximum Internal Storage | Hot Plug SCSI |
2.40TB |
6 x 300GB with standard drive
cage + 2 x 300GB with optional ML3xx Two Bay Hot Plug SCSI Drive Cage |
| Hot Plug SATA |
4.50TB | 2 x 7GB with standard controller
+ 4 x 750GB with optional SATA array controller |
|
| Hot Plug SAS (3.5") | 876GB | 6 x 146GB with optional Smart Array P600 Controller | |
|
|
|||
| Interfaces | Parallel | 1 |
| Serial | 1 (optional 2nd serial port available) | |
| Pointing Device (Mouse) | 1 | |
| Graphics | 1 | |
| Keyboard | 1 | |
| Network RJ-45 | 2 (1 dedicated for iLO) | |
| USB 2.0 Ports | 3 total: 1 front, 1 internal,
1 rear NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html. |
|
| External SCSI knockouts | 2 | |
|
|
||
| Graphics | Integrated ATI RAGE XL Video
Controller with 8-MB SDRAM Video Memory VGA connector; up to 1600 x 1200 resolution supported |
|
|
|
| Form Factor | Tower or rack (5U) |
|
NOTE: Rack models (and rack conversion kit) support:
|
|
|
|
|
| ProLiant Essentials Foundation Pack Software |
| |||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. | ||||
| | ||||
| Industry Standard Compliance | ACPI V2.0 Compliant PCI 2.2 Compliant PXE Support WOL Support PCI-X 1.0 Compliant Novell Certified Microsoft® Logo certifications USB 2.0 |
|
|
|
| Availability | Optional Hot Plug, Redundant
Power supply Online Spare Memory Optional Redundant System Fan |
|
|
|
| Remote Management |
Integrated Lights-Out Standard
Integrated Lights Out Advanced Pack (optional) |
|
|
|
| System Management | HP Systems Insight Manager SmartStart Redundant ROM System Firmware Update ROMPaq ProLiant RBSU (ROM-Based Setup Utility) Automatic Server Recovery-2 (ASR-2) Dynamic Sector Repairing (with Smart Array Controller) Drive Parameter Tracking (with Smart Array Controller) Pre-Failure Warranty (covers processors, memory and SCSI/SAS hard drives) |
|
|
|
| Security | Power-on password Setup password Diskette boot control Parallel and serial interface control Disk configuration lock Power switch security |
|
|
|
| Server Power Cords | Tower models ship standard with
a 12', lowline NEMA power cord. Rack models ship standard with a 10' IEC cable. Rack models also include a 12' NEMA cord. Most redundant power supply options ship with a 12' power cord. The one exception is the IEC redundant power supply (P/N 384168-B21) which ships with a 10' IEC cable only. |
|
|
|
| UPS
and PDU Power Cord Matrix |
Please see the UPS and PDU cable
matrix that lists cable descriptions, requirements, and specifications for
UPS and PDU units: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf. |
| | |
| Power Supply | Hot plug models: 725 Watt, Power
Factor Correction (PFC), Hot Plug 100 to 240 VAC Rated Input Voltage (Auto-sensing),
CE Mark Compliant Optional 2nd power supply for hot-pluggable 1 + 1 redundancy |
|
|
|
| System Fans | 1 fan ships standard, 2 fans total supported (does not include power supply or processor heatsink fans) |
|
|
|
| Required Cabling | For required cabling information,
refer to the HP ProLiant ML350 G4p cabling matrix at http://www.hp.com/servers/proliantML350. NOTE: Please see the "Storage" section of this QuickSpecs for important information on controllers and cables required to support SAS or SATA hard drives as well as storage management software available for SATA hard drives. |
| | |
| OS Support | Microsoft Windows Server 2003
Microsoft Small Business Server 2003 Microsoft Windows 2000 Server and Advanced Server Novell NetWare Novell NetWare Small Business Suite LINUX (Red Hat, SuSE) VMware Virtualization Software |
| NOTE: For a
complete and up-to-date listing of supported operating systems please visit
our OS Support Matrix at: http://www.hp.com/go/supportos NOTE: For a complete and up-to-date information on Linux support, please visit the HP Linux Web site at http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html NOTE: Optional hardware may be required to support some operating systems. NOTE: For information on how to buy server operating systems from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant ML350, please see: http://www.compaq.com/support/files/server/us/index.html NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html |
|
|
|
|
| Installation of Server into Telco Racks | Support for all 2-post Telco racks requires the use of the HP ProLiant ML350 G4 rack kit and an additional option kit from Rack Solutions. http://www.racksolutions.com/hp. |
| | |
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
|
|
|
| HP Enterprise Configurator | The HP eCo-Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. |
| | |
| HP ProLiant Smart Buys |
The HP Smart Buy program offers
mainstream business solutions at competitive prices with excellent availability
and superior HP quality. It offers a wide range of industry-leading HP products
at compelling prices, allowing you to receive richer configurations with
additional options. NOTE: For detailed specification information on ProLiant Smart Buys please click on the following link: ftp://ftp.compaq.com/pub/products/servers/smartbuys.pdf |
| | |
| Service and Support |
This product is covered by a global limited warranty and supported by
HP Services and a worldwide network of resellers and service providers.
Hardware diagnostic support and repair is available for three years from
date of purchase. Support for software and initial setup is available
for 90 days from date of purchase. Additional support may be covered under
the warranty or available for an additional fee. Enhancements to warranty
services are available through HP Care Pack services or customized service
agreements.
Continuance Care - Recommended service delivering cost-effective support
options designed to extend HP Services committed response and guaranteed
fix times, designed to speed problem identification and resolution.
Total Care - Highest HP Support service level recommend to help increase
IT performance and availability with comprehensive, integrated hardware
and software services
Deployment Services - HP Installation and Start Up services designed
to take time, risk, and worry out of the deployment of ProLiant servers
- and free customers IT support staff to focus on what they do best, their
business.
|
|
NOTE: For a complete listing of service
offerings and information visit: |
|
|
Models
| NOTE: ProLiant Smart Buys are available in NA only. For detailed specification information on ProLiant Smart Buys please click on the following link: ftp://ftp.compaq.com/pub/products/servers/smartbuys.pdf. | ||
| Models - Tower | ||
| ML350T04p SCSI
x3.0-2MB/800, 512 MB 380165-001 |
Processor(s) | (1) Intel Xeon 3.0 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 512 MB (1 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated dual channel Ultra320 SCSI adapter | |
| Hard Drive | None ship standard (up to 6 supported) | |
| Internal Storage | 2.4TB maximum hot plug SCSI (with optional hard drives & drive cage) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Tower (5U) | |
|
|
||
| ML350T04p SCSI
x3.0-2MB/800, 1 GB Array 380173-001 |
Processor(s) | (1) Intel Xeon 3.0 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 1 GB (2 x 512MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated dual channel Ultra320 SCSI adapter | |
| RAID Controller | Smart Array 641 Controller | |
| Hard Drive | None ship standard (up to 6 supported) | |
| Internal Storage | 2.4TB maximum hot plug SCSI (with optional drive cage & hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Tower (5U) | |
|
|
||
| ML350T04p SATA/SAS
x3.0-2MB/800, 512 MB 331889-001 |
Processor(s) | (1) Intel Xeon 3.0 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 512 MB (1 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated two port SATA Integrated dual channel Ultra320 SCSI adapter |
|
| Hard Drive |
None ship standard (Up to 6 supported with optional SATA or SAS controller |
|
| Internal Storage | Hot Plug SATA - 4.5TB maximum
(with optional SATA controller & 6 hard drives) NOTE: The optional SATA RAID controller is required to support hot plug of SATA hard drives. |
|
| Hot Plug SAS - 876GB maximum (with optional SAS controller & 6 hard drives) | ||
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Tower (5U) | |
|
|
||
| ML350T04p SCSI
x3.2-2MB/800, 512 MB 380166-001 |
Processor(s) | (1) Intel Xeon 3.2 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 512 MB (1 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated dual channel Ultra320 SCSI adapter | |
| Hard Drive | None ship standard (up to 6 supported) | |
| Internal Storage | 2.4TB maximum hot plug SCSI (with optional drive cage & hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Tower (5U) | |
|
|
||
| ML350T04p SCSI
x3.2-2MB/800, 1 GB Array 380196-001 |
Processor(s) | (1) Intel Xeon 3.2 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 1 GB (2 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated dual channel Ultra320 SCSI adapter | |
| RAID Controller | Smart Array 641 Controller | |
| Hard Drive | None ship standard (up to 6 supported) | |
| Internal Storage | 2.4TB maximum hot plug SCSI (with optional drive cage & hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Tower (5U) | |
|
|
||
| ML350T04p SATA/SAS
x3.2-2MB/800, 512 MB 356816-001 |
Processor(s) | (1) Intel Xeon 3.2 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 512 MB (1 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated two port SATA Integrated dual channel Ultra320 SCSI adapter |
|
| Hard Drive | None ship standard (up to 6
supported with optional SATA or SAS controller) NOTE: Please see the "Storage" section of the QuickSpecs for important information on controllers and cables required to support SAS or SATA hard drives as well as storage management software available for SATA hard drives. |
|
| Internal Storage | Hot Plug SATA - 4.5TB maximum
(with optional SATA controller & 6 hard drives) NOTE: The optional SATA RAID controller is required to support hot plug of SATA hard drives. |
|
| Hot Plug SAS - 876GB maximum (with optional SAS controller & 6 hard drives) | ||
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Tower (5U) | |
|
|
||
| ML350T04p SCSI
x3.4-2MB/800, 512 MB 380172-001 |
Processor(s) | (1) Intel Xeon 3.4 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 512 MB (1 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated dual channel Ultra320 SCSI adapter | |
| Hard Drive | None ship standard (up to 6 supported) | |
| Internal Storage | 2.4TB maximum hot plug SCSI (with optional drive cage & hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Tower (5U) | |
|
|
||
| ML350T04p SCSI
x3.4-2MB/800, 1 GB Array 380197-001 |
Processor(s) | (1) Intel Xeon 3.4 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 1 GB (2 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated dual channel Ultra320 SCSI adapter | |
| RAID Controller | Smart Array 641 Controller | |
| Hard Drive | None ship standard (up to 6 supported) | |
| Internal Storage | 2.4TB maximum hot plug SCSI (with optional drive cage & hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Tower (5U) | |
|
|
||
| ML350T04p SATA/SAS
x3.4-2MB/800, 512 MB 370508-001 |
Processor(s) | (1) Intel Xeon 3.4 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 512 MB (1 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated two port SATA Integrated dual channel Ultra320 SCSI adapter |
|
| Hard Drive | None ship standard (up to 6
supported with optional SATA or SAS controller) NOTE: Please see the "Storage" section of these QuickSpecs for important information on controllers and cables required to support SAS or SATA hard drives as well as storage management software available for SATA hard drives. |
|
| Internal Storage | Hot Plug SATA - 4.5TB maximum
(with optional SATA controller & 6 hard drives) NOTE: The optional SATA RAID controller is required to support hot plug of SATA hard drives. |
|
| Hot Plug SAS - 876GB maximum (with optional SAS controller & 6 hard drives) | ||
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Tower (5U) | |
|
|
||
| Models - Rack | ||
| ML350R04p SCSI
x3.0-2MB/800, 512 MB 382174-001 |
Processor(s) | (1) Intel Xeon 3.0 GHz processor standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 512 MB (1 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated dual channel Ultra320 SCSI adapter | |
| Hard Drive | None ship standard (up to 6 supported) | |
| Internal Storage | 2.4TB maximum hot plug SCSI (with optional drive cage & hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Rack (5U) | |
|
|
||
| ML350R04p SCSI
x3.0-2MB/800, 1 GB Array 382195-001 |
Processor(s) | (1) Intel Xeon Processor 3.0 GHz standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 1 GB (2 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated dual channel Ultra320 SCSI adapter | |
| RAID Controller | Smart Array 641 | |
| Hard Drive | None ship standard (up to 6 supported) | |
| Internal Storage | 2.4TB maximum hot plug SCSI (with optional drive cage & hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Rack (5U) | |
|
|
||
| ML350R04p SCSI
x3.2-2MB/800, 512 MB 382177-001 |
Processor(s) | (1) Intel Xeon Processor 3.2 GHz standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 512 MB (1 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated dual channel Ultra320 SCSI adapter | |
| Hard Drive | None ship standard (up to 6 supported) | |
| Internal Storage | 2.4TB maximum hot plug SCSI (with optional drive cage & hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Rack (5U) | |
|
|
||
| ML350R04p SCSI
x3.2-2MB/800, 1 GB Array 382196-001 |
Processor(s) | (1) Intel Xeon Processor 3.2 GHz standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 1 GB (2 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated dual channel Ultra320 SCSI adapter | |
| RAID Controller | Smart Array 641 Controller | |
| Hard Drive | None ship standard (up to 6 supported) | |
| Internal Storage | 2.4TB maximum hot plug SCSI (with optional drive cage & hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Rack (5U) | |
|
|
||
| ML350R04p SCSI
x3.4-2MB/800, 512 MB 382197-001 |
Processor(s) | (1) Intel Xeon Processor 3.4 GHz standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 512 MB (1 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated dual channel Ultra320 SCSI adapter | |
| Hard Drive | None ship standard (up to 6 supported) | |
| Internal Storage | 2.4TB maximum hot plug SCSI (with optional drive cage & hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Rack (5U) | |
|
|
||
| ML350R04p SCSI
x3.4-2MB/800, 1 GB Array 382178-001 |
Processor(s) | (1) Intel Xeon Processor 3.4 GHz standard (up to 2 supported) |
| Cache Memory | Integrated 2MB Level 2 cache | |
| Standard Memory | 1 GB (2 x 512 MB) | |
| Network Controller | Embedded NC7761 Gigabit Server Adapter | |
| Storage Controller | Integrated dual channel Ultra320 SCSI adapter | |
| RAID Controller | Smart Array 641 Controller | |
| Hard Drive | None ship standard (up to 6 supported) | |
| Internal Storage | 2.4TB maximum hot plug SCSI (with optional drive cage & hard drives) | |
| Optical Drive | 48x IDE (ATAPI) CD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Rack (5U) |
|
|
Configuration Information - Factory Integrated Models
|
NOTE:
All configure-to-order servers must start with a CTO Chassis. Use the
following section to order a server customized to your requirements with
options integrated at the factory. The options you select in steps 2 and
3 will be integrated with the base configuration you select in step 1.
Additional options selected in Step 4 will also be integrated when applicable.
|
||
|
Step 1: Base Configuration (choose one of the following configurable models) |
||
| Models | HP ProLiant ML350G4p HP-SCSI Rack CTO Chassis | 382188-405 |
| Includes: | ||
| Embedded NC7761 Gigabit Server Adapter | ||
| Integrated dual channel Ultra320 SCSI adapter | ||
| Six Hot Plug SCSI Drive Bays | ||
| Six expansion slots: one 64-bit/133-MHz PCI-X, two 64-bit/100-MHz PCI-X, one 64-bit/66-MHz PCI-X, one x4 PCI Express, and one x8 PCI Express | ||
| Two USB ports | ||
| 725W Hot-Plug Power Supply | ||
| 5U Rack Form Factor | ||
| HP ProLiant ML350G4p HP-SCSI Tower CTO Chassis |
382187-405
|
|
| Includes: | ||
| Embedded NC7761 Gigabit Server Adapter | ||
| Integrated dual channel Ultra320 SCSI adapter | ||
| Six Hot Plug SCSI Drive Bays | ||
| Six expansion slots: one 64-bit/133-MHz PCI-X, two 64-bit/100-MHz PCI-X, one 64-bit/66-MHz PCI-X, one x4 PCI Express, and one x8 PCI Express | ||
| Two USB ports | ||
| 725W Hot-Plug Power Supply | ||
| 5U Tower form factor | ||
| Keyboard | ||
| 2-button Mouse | ||
| HP ProLiant ML350G4p Serial Tower CTO Chassis |
372798-405
|
|
| Includes: | ||
| Embedded NC7761 Gigabit Server Adapter | ||
| Integrated dual channel Ultra320 SCSI adapter | ||
| Dual port SATA controller | ||
| Six Hot Plug SATA Drive Bays | ||
| Six expansion slots: one 64-bit/133-MHz PCI-X, two 64-bit/100-MHz PCI-X, one 64-bit/66-MHz PCI-X, one x4 PCI-Express, and one x8 PCI-Express | ||
| Two USB ports | ||
| 725W Hot-Plug Power Supply | ||
| 5U Tower form factor | ||
| Keyboard | ||
| 2-button Mouse | ||
|
|
||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processors | Intel X3.0GHz/800-2MB ML350G4p FIO BASE |
382184-L21
|
| Intel X3.2GHz/800-2MB ML350G4p FIO BASE | 382182-L21 | |
| Intel X3.4GHz/800-2MB ML350G4p FIO BASE |
382180-L21
|
|
| Intel X3.6GHz/800-2MB ML350G4p FIO BASE | 370515-L21 | |
| Base Memory | 512 MB Advanced ECC PC2-3200 DDR SDRAM DIMM Kit (1 x 512 MB) |
384163-B21
|
| 1 GB Advanced ECC PC2-3200 DDR SDRAM DIMM Kit (2 x 512 MB) |
343055-B21
|
|
| 2 GB Advanced ECC PC2-3200 DDR SDRAM DIMM Kit (2 x 1024 MB) |
343056-B21
|
|
| 4 GB Single-Rank Adv. ECC PC2-3200 DDR SDRAM DIMM Kit (2 x 2048 MB) |
343057-B21 |
|
| Optical Drive | DVD-ROM Drive Option Kit |
217053-B21
|
| CD-RW/DVD-ROM Combo Drive Option Kit |
331346-B21
|
|
| HP DVD+R/RW 16X Half Height |
383974-B21
|
|
| HP 48X CD-ROM ALL (no screws) |
384758-B21
|
|
|
|
||
| Step 3: Choose Additional Factory Integratable Options | ||
| SAS Starter Kit | NOTE: The new HP ProLiant ML350 G4p SAS Starter Kit makes migration to SAS easy and affordable. The SAS Starter Kit includes the Smart Array P600 Controller, two 72GB 15K rpm SAS hard drives, and two required SAS cables. | |
| HP ProLiant ML350 G4p SAS Starter Kit | 393684-B21 | |
| Controllers | Smart Array 641 Controller | 291966-B21 |
| Smart Array 642 Controller | 291967-B21 | |
| Smart Array 6402/128 Controller |
273915-B21
|
|
| Smart Array 6404/256 Controller |
273914-B21
|
|
| 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
|
| HP Smart Array P600 Controller |
337972-B21
|
|
| Hard Drives | Ultra320 Hot Plug (For use with HP-SCSI CTO Chassis) | |
| HP 300GB U320 10K Universal HDD |
350964-B22
|
|
| HP 146GB U320 10K Universal HDD |
286716-B22
|
|
| HP 72GB U320 10K Universal HDD |
286714-B22
|
|
| HP 300GB U320 15K Universal HDD |
411089-B22
|
|
| HP 146GB U320 15K Universal HDD |
347708-B22 |
|
| HP 72GB U320 15K Universal HDD |
286778-B22
|
|
| HP 36GB U320 15K Universal HDD |
286776-B22
|
|
| SATA Hot Plug (For use with Serial CTO Chassis) | ||
| HP 750GB 1.5G SATA 7.2K 3.5" HDD |
432341-B21
|
|
| HP 500GB 1.5G SATA
7.2K 3.5" HDD |
395473-B21
|
|
| HP 250GB 1.5G SATA
7.2K 3.5" HDD |
349239-B21
|
|
| HP 160GB 1.5G SATA
7.2K 3.5" HDD |
349238-B21
|
|
| HP 80GB 1.5G SATA 7.2K 3.5" HDD |
349237-B21
|
|
| SAS 3.5" Hot Plug (For use with Serial CTO Chassis) | ||
| HP 146GB 3G SAS 15K 3.5" SP HDD |
375872-B21
|
|
| HP 72GB 3G SAS 15K 3.5" SP HDD |
375870-B21
|
|
| HP 36GB 3G SAS 15K 3.5" SP HDD |
375868-B21
|
|
| Hard Drive Cable | HP Internal SAS/SATA
Cable, 30 inch multi-lane NOTE: The SAS cable above supports four drives. Two cables are required when more than four drives are installed. These cables and HP Smart Array P600 RAID controller are required to support Serial Attached SCSI (SAS) hard drives. Refer to the ML350 G4p Cable Matrix for detailed information (http://www.hp.com/servers/proliantML350). |
389662-B21
|
| Modems | Agere 2006 PCI
Hi-Speed 56K Sof FIO NOTE: This part number must be used for factory integration. For field integration (or as an additional "ship along" option) choose EK694AA. |
440519-B21
|
|
|
||
| Step 4: Choose Additional Options for Factory Integration | ||
| NOTE: For additional options, please refer to the "Options" section below. Some options may not be available for factory integration. Please contact an HP sales representative for additional information. |
|
|
Options
| NOTE: Some options may not be factory integratable. Please contact your local sales representative for additional information. | ||
| HP ProLiant ML350 G4p Unique Options | Hot Plug Redundant Power Supply Option Kit |
384168-001
|
| Hot Plug Redundant
Power Supply Option Kit (IEC) NOTE: PN 384168-B21 contains the redundant power supply with an IEC power cable. Purchase this kit only when connecting to a PDU or UPS that supports IEC cables. All other kits contain country specific power cables. |
384168-B21
|
|
| ProLiant ML350 G4 Tower to Rack Conversion Kit |
358350-B21
|
|
| ML350 G4 Redundant System Fan Kit |
365866-B21
|
|
|
|
||
| ProLiant
Essentials Value Pack Software |
ProLiant Essentials Intelligent Networking Pack | |
| ProLiant Essentials
Intelligent Networking Pack - Windows Edition, Single Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
436225-B21 |
|
| NOTE: For additional ProLiant Intelligent Networking Pack - Windows License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12062_na/12062_na.html | ||
| ProLiant Essentials Intelligent Networking Pack - Linux Edition, Single Server License |
436229-B21
|
|
| NOTE:
For additional ProLiant Intelligent Networking Pack - Linux License Kits
please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12327_na/12327_na.html |
||
| ProLiant Essentials Performance Management Pack | ||
| ProLiant Essentials
Performance Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key, HP Management CD and documentation. NOTE: The most recent version of the software can always be downloaded at http://www.hp.com/products/pmp. |
306696-B21 |
|
| NOTE: For additional ProLiant Performance Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_na/11925_na.html | ||
| ProLiant Essentials Rapid Deployment Pack Windows Edition Release | ||
| Rapid Deployment
Pack, Single-Server License NOTE: This license allows 1 server to be deployed and managed via RDP. |
267196-B21 |
|
| NOTE: For additional ProLiant Essentials Rapid Deployment Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.html | ||
| ProLiant Essentials Workload Management Pack | ||
| ProLiant Essentials Workload Management Pack, Single Server License |
303284-B21
|
|
| NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_na/11452_na.html | ||
| ProLiant Essentials Virtualization Management Software | ||
| ProLiant Essentials
Virtual Machine Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
435661-B21 |
|
| ProLiant
Essentials Server Migration Pack, Single-Migration License NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation. NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005. |
435663-B21
|
|
| NOTE: For additional ProLiant Essentials Virtualization Management Software License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_na/12328_na.html | ||
| ProLiant Essentials Vulnerability and Patch Management Pack | ||
| ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
371645-B21
|
|
| NOTE: For additional ProLiant Vulnerability and Patch Management Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_na/12111_na.html | ||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. |
||
|
|
||
| Remote Management | Integrated Lights-Out Advanced Pack | |
| Integrated Lights-Out
Advanced Pack, 1 server Featuring: Sophisticated virtual administration features for ultimate control of servers in the data centers and remote sites. |
263825-B21
|
|
| NOTE: For additional Integrated Light-Out Advanced Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11052_na/11052_na.html | ||
|
|
||
| ProLiant Software Maintenance Subscription | ProLiant Software Maintenance Subscription |
355060-B21
|
| ProLiant Software Maintenance Single Release |
356573-B21
|
|
| ProLiant Foundation Pack Single Release |
356604-B21
|
|
| NOTE: Please see
the SmartStart QuickSpecs for additional information regarding the subscription
purchase: http://h18000.www1.hp.com/products/quickspecs/north_america/11073.html |
||
|
|
||
| Processors | Intel Xeon 3.6 GHz-2MB Processor Option Kit | 370515-B21 |
| Intel Xeon 3.4 GHz-2MB Processor Option Kit | 382180-B21 | |
| Intel Xeon 3.2 GHz-2MB Processor Option Kit |
382182-B21
|
|
| Intel Xeon 3.0 GHz-2MB Processor Option Kit |
382184-B21
|
|
|
|
||
|
Memory (DIMMs) |
NOTE: The HP ProLiant
ML350 G4p requires interleaved memory configurations when more than one
DIMM is installed. Non-array models of the ML350 G4p ship standard with
a single DIMM. Note that when upgrading system memory, DIMMs must be configured
in identical pairs. |
|
| 512 MB Advanced ECC PC2-3200 DDR2
SDRAM DIMM Kit (1 x 512 MB) |
384163-B21
|
|
| 1 GB Advanced ECC PC2-3200 DDR2
SDRAM DIMM Kit (2 x 512 MB) |
343055-B21
|
|
| 2 GB Advanced ECC PC2-3200 DDR2
SDRAM DIMM Kit (2 x 1024 MB) |
343056-B21
|
|
| 4 GB Single-Rank Adv. ECC PC2-3200
DDR2 SDRAM DIMM Kit (2 x 2048 MB) |
343057-B21
|
|
| 4 GB Dual-Rank Adv. ECC PC2-3200 DDR2 SDRAM DIMM Kit (2 x 2048 MB) |
375004-B21
|
|
|
|
||
|
Internal Storage Upgrades |
Duplex Ultra320 SCSI Backplane
Option Kit |
339323-B21
|
| ML3xx Two Bay Hot Plug SCSI Drive
Cage NOTE: The drive cage option kit (PN 244059-B21) has one 1" drive bay and one 1.6" drive bay. It installs in two removable media bays. |
244059-B21
|
|
|
|
||
|
Optical Drives |
CD-RW/DVD-ROM Combo Drive Option
Kit NOTE: The DVD-ROM drive is supported in either the CD-ROM bay or a removable media bay. If placed in a removable media bay, it requires the 2-Device IDE cable (PN 305381-B21). |
331346-B21
|
| DVD-ROM Drive Option Kit | 217053-B21 | |
| HP DVD+R/RW 16X Half Height | 383974-B21 | |
|
|
||
|
Serial Port Kit |
ProLiant Second Serial Port Option Kit | 390390-B21 |
|
|
||
| Hard Drives | Ultra320 – Universal Hot Plug | |
| HP 300GB U320 10K Universal HDD |
350964-B22
|
|
| HP 146GB U320 10K Universal HDD |
286716-B22
|
|
| HP 72GB U320 10K Universal HDD |
286714-B22
|
|
| HP 300GB U320 15K Universal HDD |
411089-B22
|
|
| HP 146GB U320 15K Universal HDD |
347708-B22
|
|
| HP 72GB U320 15K Universal HDD |
286778-B22
|
|
| HP 36GB U320 15K Universal HDD |
286776-B22
|
|
| NOTE:
Please see the Ultra320 Universal Hot Plug Hard Drive QuickSpecs for
additional technical information on the hard drives Support details, please
see the following: http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html |
||
| Serial ATA (SATA) Hot Plug | ||
| HP 750GB 1.5G SATA 7.2K 3.5" HDD |
432341-B21
|
|
| HP 500GB 1.5G SATA 7.2K 3.5"
HDD |
395473-B21
|
|
| HP 250GB 1.5G SATA 7.2K 3.5"
HDD |
349239-B21
|
|
| HP 160GB 1.5G SATA 7.2K 3.5"
HDD |
349238-B21
|
|
| HP 80GB 1.5G SATA 7.2K 3.5" HDD |
349237-B21
|
|
| NOTE: SATA drives
have a 1-year warranty. Please see the SATA Hard Drive QuickSpecs for additional
technical information on the hard drives Support details, please see the
following: http://h18000.www1.hp.com/products/quickspecs/11940_na/11940_na.html |
||
| SAS 3.5" Hot Plug (For use with Serial CTO Chassis) | ||
| HP 146GB 3G SAS 15K 3.5" SP HDD |
375872-B21
|
|
| HP 72GB 3G SAS 15K 3.5" SP HDD |
375870-B21
|
|
| HP 36GB 3G SAS 15K 3.5" SP HDD |
375868-B21
|
|
| NOTE: Please see
the SAS Hard Drive QuickSpecs for additional technical information on the
hard drives and support details: http://h18000.www1.hp.com/products/quickspecs/12244_na/12244_na.html |
||
|
|
||
| Hard Drive Cables | HP Internal SAS/SATA Cable, 30
inch multi-lane NOTE: The SAS cable above supports four hard drives. Two cables are required to support more than 4 hard drives. These cables and HP Smart Array P600 RAID controller are required to support Serial Attached SCSI (SAS) hard drives. Refer to the ML350 G4p Cable Matrix for detailed information (http://www.hp.com/servers/proliantML350). |
389662-B21
|
|
|
||
| Storage Controllers | SCSI Controllers | |
| Smart Array 6402/128 Controller |
273915-B21
|
|
| Smart Array 6404/256 Controller |
273914-B21
|
|
| Smart Array 641 Controller |
291966-B21
|
|
| Smart Array 642 Controller |
291967-B21
|
|
| 128-MB BBWC (Battery-Backed Write
Cache) Enabler NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array 642 Controller. |
351580-B21
|
|
| Ultra320 Expansion Module for SA-6402 |
273911-B21
|
|
| 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
|
|
NOTE: Please see the following QuickSpecs for Technical Specifications
and additional information: |
||
| Serial ATA (SATA) Controller | ||
| HP 6-port SATA RAID Controller |
372953-B21
|
|
| NOTE: Please see
the following Controller or SCSI Adapter QuickSpecs for Technical Specifications
http://h18000.www1.hp.com/products/quickspecs/12091_na/12091_na.html (6-Port SATA RAID Controller) |
||
| SAS Controller |
||
| Smart Array P600 Controller | ||
| HP Smart Array P600/256 BBWC Controller |
337972-B21
|
|
| 512MB DDR BBWC Upgrade NOTE: For Smart Array P600 Controller only. |
372538-B21
|
|
| NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12247_na/12247_na.html (Smart Array P600 Controller) |
||
| SAS
HBA |
||
| HP 8 Internal Port SAS HBA with RAID |
347786-B21
|
|
|
NOTE: Please see the following QuickSpecs for additional information: |
||
|
|
||
| Communications | HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter |
367132-B21
|
| HP NC310F PCI-X 1000SX Gigabit Server Adapter |
368169-B21
|
|
| HP NC320T PCI Express 1000T Gigabit Server Adapter |
367047-B21
|
|
| HP NC340T PCI-X 4-port 1000T Gigabit Server Adapter |
391661-B21
|
|
| HP NC360T PCI Express Dual Port Gigabit Server Adapter |
412648-B21
|
|
| HP NC373F PCI Express Multifunction Gigabit Server Adapter |
394793-B21
|
|
| HP NC373T PCI Express Multifunction Gigabit Server Adapter |
394791-B21
|
|
| HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter |
394795-B21
|
|
| HP NC1020 PCI 1000T Gigabit Server Adapter |
353377-B21
|
|
| HP NC7771 PCI-X 1000T Gigabit Server Adapter |
290563-B21
|
|
| NOTE: NC61XX, NC71XX, NC77XX, or NC1020 network adapter (NIC) can be used for redundancy with the embedded NC7761 NIC. When either the embedded NC7761 or the NC1020 is teamed with other HP Ethernet adapters, Jumbo Frames and LSO features are automatically disabled. | ||
| 2006 Agere PCI high-speed international soft modem |
EK694AA
|
|
|
|
||
|
Management Options |
Remote Insight Lights-Out Edition II |
227251-001 |
|
|
||
|
Tape Drives |
| ||||||||||||||||||||||||||||||||
| | |||||||||||||||||||||||||||||||||
| Tape Autoloaders |
HP StorageWorks DAT Autoloader | |
| HP StorageWorks DAT 72x10 tape autoloader | AE313A | |
| HP StorageWorks 1/8 Tape Autoloader | ||
| HP StorageWorks 1/8 Ultrium 920 G2 Tape Autoloader | AH165A | |
| HP StorageWorks 1/8 Ultrium 448 G2 Tape Autoloader | AH164A | |
| HP StorageWorks 1/8 Ultrium 232 G2 Tape Autoloader | AH163A | |
| HP StorageWorks 1/8 G2 Tape Autoloader
Rack Kit NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions |
AH166A | |
| NOTE: Please reference
the 1/8 Tape Autoloader QuickSpecs at http://www.hp.com/go/automation
for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs |
||
|
|
||
|
Tape Libraries |
HP StorageWorks MSL2024 Tape
Library |
|
| HP StorageWorks MSL2024 1 Ultrium 960 Drive Library | AG115A | |
| HP StorageWorks MSL2024 1 Ultrium 960 4GB FC Drive Library | AG326B | |
| HP StorageWorks MSL2024 1 Ultrium 920 Drive Library | AH169A | |
| HP StorageWorks MSL2024 2 Ultrium 920 Drive Library | AH170A | |
| HP StorageWorks MSL2024 1 Ultrium 448 Drive Library | AG116A | |
| HP StorageWorks MSL2024 2 Ultrium 448 Drive Library | AG117A | |
| HP StorageWorks MSL4048 Tape Library | ||
| HP StorageWorks MSL4048 1 Ultrium 448 Drive Library | AG320A | |
| HP StorageWorks MSL4048 2 Ultrium 448 Drive Library | AG321A | |
| HP StorageWorks MSL4048 1 Ultrium 920 Drive Library | AH171A | |
| HP StorageWorks MSL4048 2 Ultrium 920 Drive Library | AH172A | |
| HP StorageWorks MSL4048 1 Ultrium 960 Drive Library | AG322A | |
| HP StorageWorks MSL4048 1 Ultrium 960 4GB FC Drive Library | AG324B | |
| HP StorageWorks MSL4048 2 Ultrium 960 Drive Library | AG323A | |
| HP StorageWorks MSL4048 2 Ultrium 960 4GB FC Drive Library | AG325B | |
| HP StorageWorks MSL6000 Tape Library | ||
| Ultrium 960 technology | ||
| HP StorageWorks MSL6030 1 Ultrium 960 Dr LVDS Library | AD606B | |
| HP StorageWorks MSL6030 1 Ultrium 960 Dr FC Library | AD608B | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr LVDS Library | AD607B | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr FC Library | AD609B | |
| Ultrium 460 technology | ||
| HP StorageWorks MSL6030 1 Ultrium 460 Dr LVDS Library | AD598B | |
| HP StorageWorks MSL6030 1 Ultrium 460 Dr FC Library | AD600B | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr LVDS Library | AD599B | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr FC Library | AD601B | |
| NOTE: Please reference the MSL2024, MSL4048, and MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs | ||
|
|
||
|
HP Data Protector Express Software |
HP DP Express Backup Server Upgrade for ProLiant Software | BB117AP |
| HP DP Express Package for Microsoft Small Business Server | BB118AA | |
|
NOTE: Please see the HP Data Protector Express QuickSpecs for
additional information regarding the purchase of HP Data Protector Express
software: NOTE: To obtain a free licensed copy of HP Data Protector Express for ProLiant edition software, please visit the "Protect Your Data" link accessible from your ProLiant server's System Management Homepage (SMH) software (SmartStart 7.5 or later). |
||
|
|
||
|
HP StorageWorks Modular Smart Array 20 |
HP StorageWorks Modular Smart Array 20 NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. | 335921-B21 |
| HP StorageWorks Modular Smart Array 20 Starter
Kit NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. Includes Smart Array 6402/128 Controller. | 366172-B21 | |
| NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 3.5” Hot Plug Hard Drives. | ||
|
|
||
|
HP StorageWorks Modular Smart Array 30 |
HP StorageWorks Modular Smart Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies | 302969-B21 |
| HP StorageWorks Modular Smart Array 30 DB NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies | 302970-B21 | |
| NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 Hot Plug Hard Drives. | ||
|
|
||
|
HP StorageWorks Modular Smart Array 50 |
HP StorageWorks Modular Smart Array 50 Enclosure | 364430-B21 |
| NOTE:
Please see the Modular Smart Array 50 QuickSpecs for additional information
including configuration steps and additional options needed for a complete
solution at: http://h18000.www1.hp.com/products/quickspecs/12245_na/12245_na.html | ||
|
|
||
|
HP StorageWorks Modular Smart Array 500 |
HP StorageWorks Modular Smart Array 500 Generation 2 | 335880-B21 |
| NOTE: Please see the Modular
Smart Array 500 Generation 2 QuickSpecs for additional information including
configuration steps and additional options needed for a complete solution
at: http://h18000.www1.hp.com/products/quickspecs/11956_na/11956_na.html | ||
|
|
||
|
HP StorageWorks Modular Smart Array 1000 |
HP StorageWorks Modular Smart Array 1000 | 201723-B22 |
| NOTE: Please see the Modular
Smart Array 1000 QuickSpecs for additional options and configuration information
at http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html | ||
|
|
||
|
HP StorageWorks Modular Smart Array 1500 cs |
Modular Smart Array 1500 Controller Shelf | AA986A |
| NOTE: Please see the StorageWorks
Modular SAN Array 1500 cs QuickSpecs for additional options and configuration
information at: http://www.hp.com/go/MSA1500cs | ||
|
|
||
| Cluster Options | ProLiant Cluster Starter Kit |
364023-B22
|
| NOTE: For additional
information regarding the ProLiant Cluster Starter Kit please see the following
QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11935_na/11935_na.html |
||
| HP HA/F200 for Entry SAN Cluster |
364026-B22 |
|
| NOTE: For additional
information regarding the ProLiant Cluster for Entry Level SAN please see
the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11932_na/11932_na.html |
||
| ProLiant Cluster HA/F500 for the Enterprise SAN |
364024-B21
|
|
| NOTE: For additional
information regarding the ProLiant Cluster HA/F500 for Enterprise SAN please
see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11933_na/11933_na.html |
||
| HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 & 10 and Red Hat EL 3 & 4 (2 node license cluster kit) |
305199-B26
|
|
| HP Serviceguard for Linux A.11.16 for SUSE SLES 9 & 10 and Red Hat EL 3 & 4 (single license version) |
307754-B26
|
|
| HP Serviceguard for Linux and Red Hat Global File System - 1 year subscription |
T2798AA#001
|
|
| HP Serviceguard for Linux and Red Hat Global File System - 3 years subscription |
T2798AA#003
|
|
| NOTE: For additional
information regarding HP Serviceguard for Linux, please see the following
QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html |
||
|
|
||
| StorageWorks Options | NOTE: The following
is a list of all Fibre Channel Host Bus Adapters for Windows and Linux.
For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html |
|
| HP StorageWorks FC2142SR 4Gb PCI-e HBA |
A8002A
|
|
| HP StorageWorks FC2242SR Dual Channel 4 Gb PCI-e HBA |
A8003A
|
|
| HP StorageWorks FC1142SR 4Gb PCI-e HBA |
AE311A
|
|
| HP StorageWorks FC1242SR Dual Channel 4 Gb PCI-e HBA |
AE312A
|
|
| HP StorageWorks FC2143 4Gb PCI-X 2.0 -to-Fibre Channel HBA |
AD167A
|
|
| HP StorageWorks FC2243 Dual Channel 4Gb PCI-X 2.0 HBA |
AD168A
|
|
| HP StorageWorks FC1143 4Gb PCI-X 2.0 HBA |
AB429A
|
|
| HP StorageWorks FC1243 Dual Channel 4Gb PCI-X 2.0 HBA |
AE369A
|
|
|
|
||
|
Uninterruptible Power Systems – Tower UPS |
HP, T1000 UPS |
AF403A
|
|
HP, T1500 UPS |
AF406A
|
|
| HP, R/T 2200 UPS |
AF409A
|
|
|
|
||
|
Uninterruptible Power Systems Rack UPS |
HP, R1.5kVA UPS, 1U |
AF419A
|
| HP R3000 VA UPS, 2U, L5-30 NOTE: Replaces non-RoHs compliant part number 192186-001. |
AF422A | |
| HP R3000 VA UPS, 2U, L6-20 NOTE: Replaces non-RoHs compliant part number 192186-002. |
AF423A | |
| HP R5500 VA UPS NOTE: Replaces non-RoHs compliant part number 326529-D71. |
AF426A | |
|
|
||
| HP Monitored Power Distribution Unit (PDU) | HP Monitored Power Distribution Unit: Full Rack Version | |
| HP 17.3 kVA S2324 Monitored PDU-
dual input, 3U, 24A NOTE: Replaces non-RoHs compliant part number 370959-D71. |
AF503A
|
|
| HP 8.3 kVA S1324 Monitored PDU-
single input, 3U, 24A NOTE: Replaces non-RoHs compliant part number 370960-D71. |
AF504A
|
|
| HP 16.6 kVA S2140 Monitored PDU-
dual input, 1U, 40A NOTE: Replaces non-RoHs compliant part number 37061-D71. |
AF505A
|
|
| HP 8.6 S1140 Monitored PDU- single
input, 1U, 40A NOTE: Replaces non-RoHs compliant part number 370962-D71. |
AF506A
|
|
|
|
||
| Modular PDUs
1U/0U (Up to 32 outlets) NOTE: 1U/0U mounting brackets shipped with the unit (optimized for 10000 and 9000 series racks). |
HP Modular Power Distribution
Units (mPDU), Low Volt Model, 24A (100-127 VAC) NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of the UPS R3000 XR. |
252663-D71 |
| HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC) |
252663-D72 |
|
| HP Modular Power Distribution
Units (mPDU), High Volt Model, 40A (200-240 VAC) NOTE: This mPDU (252663-B21), 40A model has a hardwired input. |
252663-B21 |
|
| HP Modular Power Distribution
Units (mPDU), High Volt Model, 16A (200-240 VAC) NOTE: This PDU has a detachable input power cord and allows for adaptability to country specific power requirements. This model may also be used with the high volt UPSs R3000 XR and R6000, need to order cable PN 340653-001. |
252663-B24 |
|
| HP Modular Power Distribution Unit (mPDU), High Volt Model, 40A, Attached Cord |
252663-D73
|
|
| NOTE: Please see
the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables and country specific
power cords: http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html |
||
|
|
||
| USB Options | HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver) |
DC172B
|
| USB 1.44-MB External Diskette Drive (Carbonite) |
DC141B
|
|
| HP USB 04 Standard Keyboard |
DT528A#ABA
|
|
| USB 2.0 4-port HUB |
DG954A
|
|
| HP 1GB Drive Key II- USB 2.0 Flash Drive |
AG382AA
|
|
| HP 512MB DriveKey II- USB Flash Drive |
ED516AA
|
|
|
|
||
| Other | ProLiant ML3xx Internal to External SCSI Cable Option Kit (HD68) |
159547-B22
|
| ProLiant ML3xx Internal to External
SCSI Cable Option Kit (VHDCI) |
333370-B21
|
|
|
|
||
|
Rack Conversion Kit |
ProLiant ML350 G4 Tower to Rack Conversion Kit |
358350-B21
|
| Shipping Bracket for Round Hole
Racks NOTE: Required when shipping the server pre-installed in round hole rack. Square hole pre-configured rack shipping hardware included with server mounting rails. |
371482-B21 | |
|
|
||
| HP Rack 5000 Series (Graphite Metallic) | HP 5642 Rack-Unassembled |
358254-B21
|
| NOTE: Please see
the HP Rack 5642 QuickSpecs for additional part numbers and Technical Specifications
such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.html NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. |
||
|
|
||
|
HP Rack 10000 G2 Series |
10642 G2 (42U) Rack Cabinet - Pallet |
AF001A
|
| 10642 G2 (42U) Rack Cabinet - Shock Pallet |
AF002A
|
|
| 10642 G2 (42U) Rack Cabinet - Crated |
AF003A
|
|
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet |
AF004A
|
|
| 10636 G2 (36U) Rack Cabinet - Pallet |
AF011A
|
|
| 10636 G2 (36U) Rack Cabinet - Shock Pallet |
AF012A
|
|
| 10636 G2 (36U) Rack Cabinet - Crated |
AF013A
|
|
| 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet |
AF014A
|
|
| NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed. | ||
| NOTE: Please see
the Rack 10000 G2 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html |
||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
|
||
| HP Rack 10000
Series (Graphite Metallic) |
HP S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22
|
| HP 10842 (42U) Rack Cabinet - Pallet |
257415-B21
|
|
| HP 10842 (42U) Rack Cabinet - Shock Pallet |
257415-B22
|
|
| HP 10647 (47U) Rack Cabinet - Pallet |
245160-B21
|
|
| HP 10647 (47U) Rack Cabinet - Crated |
245160-B23
|
|
| HP 10622 (22U) Rack Cabinet - Pallet |
245163-B21
|
|
| HP 10622 (22U) Rack Cabinet - Shock Pallet |
245163-B22
|
|
| HP 10622 (22U) Rack Cabinet - Crated |
245163-B23
|
|
| NOTE: xxxxxx-B21 (pallet) used to ship empty racks shipped on a truck. -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). xxxxxx-B23 (crated) used for air shipments of empty racks. | ||
| NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. Not all Compaq equipment is qualified to be shipped in the Rack 10000 series. | ||
| NOTE: Please see
the Rack 10000 QuickSpecs for Technical Specifications such as height, width,
depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html |
||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower | ||
|
|
||
| Keyboards and Monitors | TFT7210R Rack Mounted 17" Monitor |
348373-B21
|
| NOTE: For a complete
list of Monitors please view the following URL: http://www.hp.com/go/kvm |
||
| TFT7600 Rackmount Keyboard Monitor |
AG052A
|
|
| 1U Rackmount Keyboard with USB |
AG072A
|
|
| NOTE: For additional information regarding Rack Options, please see the following URL: http://ww.hp.com/go/rackandpower | ||
|
|
||
| HP KVM Switch Options | 2x1x16 IP Console Switch with Virtual Media |
AF601A
|
| 4x1x16 IP Console Switch with Virtual Media |
AF602A
|
|
| 2x16 Server Console Switch with Virtual Media |
AF600A
|
|
| PS/2 Virtual Media Interface Adapter,
1 pack NOTE: Requires PS/2 and one USB port on server. |
AF604A
|
|
| Server Console Switch (KVM), 0 x 1 x 8 port |
336044-B21
|
|
| Server Console Switch (KVM), 0 x 2 x 16 port |
336045-B21
|
|
| PS/2 Interface Adapter, 1 pack |
262588-B21
|
|
| PS/2 Interface Adapter, 8 pack |
262587-B21
|
|
| USB Interface Adapter, 1 pack |
336047-B21
|
|
| Serial Interface adapter - 1 Pack with power supply |
373035-B21
|
|
| NOTE: Cat5e cables
are required to connect Interface Adapters to Console Switches. Cat5e cables
can be found at the following URL: http://www.hp.com/go/kvm. |
||
| HP 1x 4 USB/PS2 KVM Switch, TT |
371301-D71
|
|
| HP 1x 4 USB/PS2 KVM Switch, RM |
371302-B21
|
|
| HP PS2 KVM Cable with audio, 6', 2-pack |
371730-B21
|
|
| HP USB KVM Cable with audio, 6', 2-pack |
371729-B21
|
|
| NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. |
||
|
|
||
| HP Serial Console Server Options | HP 16 Port Serial Console Server |
AF101A
|
| HP 48 Port Serial Console Server |
AF102A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack |
AF103A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack |
AF104A
|
|
| NOTE: Cat5e cables
are required to connect Serial Adapters to Serial Console Servers. Additional
Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. |
||
| NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. |
||
|
|
||
| Service and Support Offerings (HP Care Pack Services) |
|
|||||||||
|
||||||||||
|
||||||||||
|
|
|
Memory
|
HP ProLiant ML350 G4p Memory Configuration |
|
Pair 1
|
Pair 2
|
Pair 3
|
||||
|
Total Capacity Required
|
Base Memory
(Non-Array Models) |
DIMM Upgrade #1
|
DIMM Upgrade #2
|
DIMM Upgrade #3
|
||
|
512 MB
|
512 MB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
|
1 GB
|
512 MB
|
512 MB
|
Empty
|
Empty
|
Empty
|
Empty
|
|
2 GB
|
512 MB
|
512 MB
|
512 MB
|
512 MB
|
Empty
|
Empty
|
|
4 GB
|
512 MB
|
512 MB
|
512 MB
|
512 MB
|
1 GB
|
1 GB
|
|
|
Pair 1
|
Pair 2
|
Pair 3
|
|||
|
Total Capacity Required
|
Base Memory
(Array Models) |
DIMM Upgrade #1
|
DIMM Upgrade #2
|
|||
|
1 GB
|
512 MB
|
512 MB
|
Empty
|
Empty
|
Empty
|
Empty
|
|
2 GB
|
512 MB
|
512 MB
|
512 MB
|
512 MB
|
Empty
|
Empty
|
|
4 GB
|
512 MB
|
512 MB
|
512 MB
|
512 MB
|
1 GB
|
1 GB
|
| Installing maximum memory | ||||||
| Maximum Capacity |
Pair 1
|
Pair 2
|
Pair 3
|
|||
|
12 GB
|
2 GB
Single Rank |
2 GB
Single Rank |
2 GB
Single Rank |
2 GB
Single Rank |
2 GB
Single Rank |
2 GB
Single Rank |
|
Following are memory options available from HP: |
|
|
384163-B21 |
|
343055-B21 |
|
343056-B21 |
|
343057-B21 |
|
375004-B21 |
| NOTE: Online Spare
Memory is not supported when using 2-rank DIMMs. A total of 8 ranks are
supported on the HP ProLiant ML350 G4p, A maximum of 4, 2-rank DIMMs can
be populated. If you plan to mix DIMM types, 2-rank DIMMs must be installed
in the first bank, 1 rank DIMMs can then be installed in subsequent banks. The following is the memory population rules for the HP ProLiant ML350 G4p. Key: S denotes single rank kit, D denotes Dual rank kit, and X denotes no install. |
|||
|
Bank A
|
Bank B
|
Bank C |
NOTES:
|
|
S
|
X
|
X
|
|
|
S
|
S
|
X
|
|
|
S
|
S
|
S
|
|
|
D
|
X
|
X
|
Online spare not supported
|
|
D
|
S
|
X
|
Online spare not supported
|
|
D
|
S
|
S
|
Online spare not supported
|
|
D
|
D
|
X
|
Online spare not supported
|
|
|
Storage
![]() |
0 - 5
|
6 Hot Plug SCSI Hard Drive Bays |
|
or
|
||
|
S1-S6
|
6 Hot plug SATA Hard Drive Bays | |
|
D
|
1.44 MB Diskette Drive | |
|
C
|
48x CD-ROM | |
|
A,B
|
Available half height bay | |
|
Drive Support |
|||
|
|
|||
|
Quantity |
Position |
|
|
|
Removable Media |
|||
| 1.44-MB Diskette Drive | Up to 1 | D | Integrated |
| IDE (ATAPI) CD-ROM Drive | Up to 2 | A, B, C | Integrated IDE |
| HP DVD±R/RW 16X Half Height |
Up to 2 | A, B, C | Integrated IDE |
| DVD-ROM Drive Option Kit | Up to 2 | A, B, C | Integrated IDE |
| ML3xx Two Bay Hot Plug SCSI Drive Cage | Up to 1 | A + B* | Integrated SCSI |
| *NOTE: The Two Bay Hot Plug SCSI Drive Cage requires the use of both available removable media bays (A+B). In most cases, it is not possible to install both a non hot plug tape drive and the two bay hot pug SCSI drive cage option. | |||
|
|
|||
| Hard Drives | |||
| Ultra320 SCSI - Hot Plug Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller |
|
| 300GB U320 10K 146GB U320 10K 72GB U320 10K 300GB U320 15K 146GB U320 15K 72GB U320 15K 36GB U320 15K |
Up to 8
|
0-5, A+B
|
Integrated Dual Channel Ultra320
SCSI Adapter Smart Array 641 Controller Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 642 Controller |
| NOTE: Use of hot plug SCSI hard drives in positions A and B requires an optional two-bay drive cage (PN 244059-B21). With Serial models, a SCSI HBA is also required. | |||
| SATA - Hot Plug | |||
|
Quantity
Supported |
Position
Supported |
Controller |
|
| 80GB 1.5G SATA 7.2K 160GB 1.5G SATA 7.2K 250GB 1.5G SATA 7.2K 500GB 1.5G SATA 7.2K 750GB 1.5G SATA 7.2K |
Up to 6
|
S1-S6
|
HP integrated 2 Port SATA controller HP 6-Port SATA RAID Controller |
| NOTE: Full hot plug capability and drive LED status support requires installation of a SATA RAID controller. The With the HP 6-Port SATA RAID Controller, hard drive configurations can be setup, monitored and managed using HP Storage Manager. HP Systems Insight Manager should not be used to view the status of SATA hard drives and SATA RAID configurations. After installing the 6-Port SATA RAID Controller, ensure that the latest firmware, drivers, and management software are downloaded from http://www.hp.com/go/support. | |||
| SAS- Hot Plug (3.5") | |||
|
Quantity
Supported |
Position
Supported |
Controller |
|
| 36GB 3G SAS 15K SP 72GB 3G SAS 15K SP 146GB 3G SAS 15K SP |
6
|
S1-S6
|
HP Smart Array P600 Controller |
|
|
|||
|
External Storage |
||||
|
Quantity |
Position |
|
||
| Modular Smart Array 20 Family | Up to 2 | External | Smart Array 6402/128 Controller Smart Array 6404/256 Controller |
|
|
Modular Smart Array 30 Family |
Up to 2 |
External |
Integrated Dual Channel Ultra320
SCSI Adapter NOTE: Connection of an external device to the embedded SCSI controller requires an internal-to-external cable (PN 159547-B22 or 333370-B21) Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 642 Controller |
|
| Modular Smart Array 50 Enclosure | Up to 2 | External | HP Smart Array P600/256 BBWC Controller | |
| Modular Smart Array 500 G2 |
1 | External | Please see the Modular Smart Array 500 G2 QuickSpecs for the latest list of supported HBAs: http://www.hp.com/go/msa500. | |
| Modular Smart Array 1500 cs or
1000 |
Please see the Modular Smart Array 1500 cs or Modular Smart Array 1000 QuickSpecs links below to determine configuration requirements | Please see the Modular Smart Array 1500 cs or Modular Smart Array 1000 QuickSpecs (URL below) for the latest list of supported HBAs. | ||
|
Modular Smart Array 1000: http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html |
||||
|
|
||||
| Tape Drives, Tape Autoloaders, & Tape Libraries | |||
|
NOTE: For an up-to-date listing
of the latest O/S Support details for each of the Tape Drives listed below,
please see the following: NOTE: For an up-to-date listing
of the latest O/S Support details for each of the Tape Autoloaders &
Tape Libraries listed below, please see the following: NOTE: For complete listing of tape drive
offerings see http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html |
|||
|
Position
Supported |
Controller |
Controller
Part Numbers |
|
| HP StorageWorks Tape Drives,
Internal DAT 24 USB DAT 40 USB DAT 72 USB |
A or B
|
USB 2.0 Port |
N/A
|
| HP StorageWorks Tape Drives,
External DAT 24 USB DAT 40 USB DAT 72 USB |
External
|
USB 2.0 Port |
N/A
|
| HP StorageWorks Tape Drives,
Internal Ultrium 232 Ultrium 448 Ultrium 920 DAT 40 DAT 72 DLT VS160 |
A or B
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
| HP StorageWorks Tape Drives,
Internal Ultrium 460 Ultrium 960 SDLT 600 |
A and B
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
| HP StorageWorks Tape Drives,
External Ultrium 232 Ultrium 448 Ultrium 460 Ultrium 920 Ultrium 960 DAT 40 DAT 72 DLT VS160 SDLT 600 |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
| HP StorageWorks Autoloaders,
External DAT 72x10 Autoloader 1/8 G2 Tape Autoloader |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
| HP StorageWorks SCSI Rack-Mount
Tape Drive Enclosures 1U Rack-Mount Kit 3U Rack-Mount Kit |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
| HP StorageWorks USB Rack-Mount
Tape Drive Enclosures 1U Rack-Mount Kit |
External
|
USB 2.0 Port |
N/A
|
| HP StorageWorks Tape Libraries,
External MSL2024 (Ultrium 448, Ultrium 920 and 960-based) MSL4048 (Ultrium 448, Ultrium 920 and 960-based) MSL6000 (Ultrium 960 and 460-based) MSL6000 (SDLT 600-based) |
External
|
Please consult the EBS connectivity matrix at http://www.hp.com/go/ebs for detailed connectivity information. |
N/A
|
|
|
Power Specifications
| Part Number | 382175-001 |
| Spare Kit | 390394-001 |
| Operational Input Voltage Range (Vrms) | 90 - 264 |
| Frequency Range (Nominal) (Hz) | 47 - 63 (50 / 60) |
|
|
| Nominal Input Voltage (Vrms) |
100
|
115
|
208
|
220
|
230
|
240
|
| Max Rated Output Wattage Rating |
725
|
725
|
725
|
725
|
725
|
725
|
| Nominal Input Current (A rms) |
9.2
|
7.9
|
4.2
|
4.0
|
3.8
|
3.6
|
| Max Rated Input Wattage Rating (Watts) |
906
|
895
|
873
|
863
|
863
|
863
|
| Max. Rated VA (Volt-Amp) |
915
|
904
|
910
|
899
|
909
|
909
|
|
Efficiency (%) |
80
|
81
|
83
|
84
|
84
|
84
|
|
Power Factor |
0.99
|
0.99
|
0.96
|
0.96
|
0.95
|
0.95
|
|
Leakage Current (mA) |
0.31
|
0.36
|
0.65
|
0.69
|
0.72
|
0.75
|
|
Maximum Inrush Current (A peak) |
15
|
17
|
30
|
32
|
34
|
35
|
|
Maximum Inrush Current duration (miliseconds) |
3
|
|||||
| NOTES: ActiveAnswers Power Calculation Power calculator is LIVE on ActiveAnswers Web site. This is an external link. Follow this link: http://h30099.www3.hp.com/configurator/powercalcs.asp To drill down to calculators: - Click on: "ProLiant Servers" - Click on the Server of interest. Example: ML350 G4p - Click on: "Power Calculator" link. (You may need to scroll down to see it) |
|
|
Technical Specifications
| System Unit - Tower | Dimensions (HxWxD) (with feet/bezel) |
18.43 x 8.66 x 25.2 in (46.8 x 22 x 64 cm) | |
| Weight (approximate) | 60 lb (27.24 kg) (without hard drives) | ||
| Input Requirements (per power supply) |
Rated Line Voltage | 100 to 120 VAC | |
| Rated Input Frequency | 50 Hz to 60 Hz | ||
| Input Power | 906W @ 100VAC | ||
| Rated Input Current | 9.2A(100VAC),4.3A(200VAC) | ||
| Rated Line Frequency | 50 to 60 Hz | ||
| BTU Rating | 3,125 BTU/hr | ||
| SCSI Connectors |
Two internal HD68 connectors | ||
| (Support for either two internal, two external, or a mix of internal/external is available. This is achieved using an internal to external SCSI cable option kit (PN 159547-B22) and either of the two SCSI knockouts.) | |||
| Power Supply Output Power (per power supply) |
Rated Steady-State Power | 725W | |
| Temperature Range | Operating | 50° to 95° F (10°
to 35° C) (No direct sustaining sunlight) |
|
| Storage (up to one year) | -40° to 158° F (-40° to 70° C) | ||
| Maximum Wet Bulb Temperature | 82.4° F (28° C) | ||
| Relative Humidity (non-condensing) |
Operating | 10% to 90% | |
| Non-operating | 5% to 90% | ||
| Acoustic Noise | Idle (Fixed Disk Drives Spinning) |
||
|
L WAd (BELS)
|
6.0 | ||
|
L pAm (dBA)
|
43 | ||
|
Operating
(Random Seeks to Fixed Disks) |
|||
|
L WAd (BELS)
|
6.0 | ||
|
L pAm (dBA)
|
43 | ||
|
|
|||
| System Unit - Rack | Dimensions (HxWxD) | 8.61 x 19 x 24 in (21.87 x 48.26 x 60.96 cm) | |
| Weight(approximate) | 60 lb (27.24 kg) (without hard drives) | ||
|
Input Requirements (per power supply) |
Rated Line Voltage | 100 to 120 VAC | |
| Rated Input Frequency | 50 Hz to 60 Hz | ||
| Input Power | 906W @ 100VAC | ||
| Rated Input Current | 9.2A(100VAC), 4.3A(200VAC) | ||
| Rated Line Frequency | 50 to 60 Hz | ||
| BTU Rating | 3,125 BTU/hr | ||
| SCSI Connectors |
Two internal HD68 connectors | ||
| NOTE: Support for either two internal, two external, or a mix of internal/external is available. This is achieved using an internal to external SCSI cable option kit, PN 159547-B22 or 333370-B21, and either of the two SCSI knockouts. | |||
| Power Supply Output Power (per power supply) |
Rated Steady-State Power | 725W | |
| Temperature Range | Operating | 50° to 95° F (10°
to 35° C) (No direct sustaining sunlight) |
|
| Storage (up to one year) | -40° to 158° F (-40° to 70° C) | ||
| Maximum Wet Bulb Temperature | 82.4° F (28° C) | ||
| Relative Humidity (non-condensing) |
Operating | 10% to 90% | |
| Non-operating | 5% to 90% | ||
| Acoustic Noise | Idle (Fixed Disk Drives Spinning) |
||
|
L WAd (BELS)
|
6.0 | ||
|
L pAm (dBA)
|
43 | ||
|
Operating
(Random Seeks to Fixed Disks) |
|||
|
L WAd (BELS)
|
6.0 | ||
|
L pAm (dBA)
|
43 | ||
|
|
|||
| Embedded NC7761 Gigabit Server Adapter | Network Interface | 10Base-T/100Base-TX/1000Base-TX | |
| Compatibility | IEEE 802.3 10Base-T | ||
| IEEE 802.3ab 1000Base-T | |||
| IEEE 802.3u 100Base-TX | |||
| Data Transfer Method | 32-bit bus-master PCI | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000Mb/s | ||
| Connector | RJ-45 | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP; up to 328 ft (100 m) | |
| 10/100/1000Base-TX | Category 5 UTP; up to 328 ft (100 m) | ||
| | |||
| Integrated Serial ATA Controller | Simultaneous drive transfer channels |
Support for up to 2 hard drives
|
| Transfer rate synchronous (maximum theoretical) | 150 MB/s per channel; 300MB/s | |
| Protocol | Serial ATA | |
| Drive support | HP Universal Serial ATA | |
| Feature |
Supports Pre-Failure Warranty of
SATA Hard Drives Support for Systems Insight Manager |
|
| OS Support | Microsoft Windows 2000 Server Microsoft Windows Server 2003 Novell NetWare Linux (Red Hat, SuSE, UnitedLinux) |
|
| NOTE: This controller does not support LED functions. This controller does not support Hot Plug functions. | ||
|
|
||
| Integrated Dual Channel Ultra320 SCSI Adapter | Drives Supported | Up to 28 SCSI devices (14 per channel) |
| Data Transfer Method | 64-bit PCI bus-master | |
| SCSI Channel Transfer Rate | 320 MB/s per channel | |
| Maximum Transfer Rate per PCI Bus (peak) | 400 MB/s per channel | |
| SCSI Protocols | Wide Ultra2 SCSI | |
| Wide-Ultra SCSI-3 | ||
| Ultra320 SCSI | ||
| Electrical Protocol | Low Voltage Differential (LVD) | |
| SCSI Termination | Active Termination | |
| External SCSI Connectors | Optional VHDCI and HD68 internal-to-external connectors | |
| Internal SCSI Connectors | Two 68-Pin Wide-Ultra SCSI-3 connectors | |
| | ||
| Smart Array 641 Controller
NOTE: The Smart Array 641 Controller ships standard with the Array Models only. |
Protocol | Ultra320 SCSI |
| SCSI Electrical Interface | Low Voltage Differential (LVD) | |
| Drives Supported | Up to 6 Ultra320, Ultra3 and Ultra2 SCSI hard drives | |
| SCSI Port Connectors SA-641 | One internal SCSI port | |
| Data Transfer Method | 64-Bit PCI bus-master | |
| PCI Bus Speed | 64-bit, 133-MHz PCI-X (1 GB/s maximum bandwidth) | |
| PCI | 3.3 volt PCI slot compatibility only | |
| Simultaneous Drive Transfer Channels | One | |
| Channel Transfer Rate | 320-MB/s total; 320-MB/s per channel | |
| Software upgradeable Firmware | Yes | |
| Cache Memory | 64-MB DRAM used for code, transfer buffers, and non-battery backed read cache | |
| Logical Drives Supported | 32 | |
| Maximum Capacity | 1.80 TB (6 X 300 GB) | |
| Memory Addressing | 64-bit, supporting servers memory greater than 4 GB | |
| RAID Support | RAID 5 (Distributed Data Guarding)
RAID 1+0 (Striping & Mirroring) RAID 1 (Mirroring) RAID 0 (Striping) |
|
| Upgradeable Firmware | 2-MB Flashable ROM | |
| Disk Drive and Enclosure Protocol Support | Ultra320, Ultra2 and Ultra3 | |
|
|
||
|
© Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |