| Processors | Dual-Core AMD Opteron™ processor Model 280 (2.4 GHz/1MB L2 cache/1 GHz HyperTransport, 68 Watts) |
| Dual-Core AMD Opteron processor Model 275 (2.2 GHz/1MB L2 cache/1 GHz HyperTransport, 68 Watts) | |
| Dual-Core AMD Opteron processor Model 270 (2.0 GHz/1MB L2 cache/1 GHz HyperTransport, 68 Watts) | |
| Dual-Core AMD Opteron processor Model 265 (1.8 GHz/1MB L2 cache/1 GHz HyperTransport, 68 Watts) | |
|
|
|
| Upgradeability | Upgradeable to dual processing |
|
|
|
| Cache
Memory |
1MB Level 2 Cache per core |
|
|
|
| Chipset | AMD® 8000 series chipset |
| | |
| Memory One of the following depending upon model |
Type | PC3200 DDR 400 MHz
(2 slots) 2:1 interleave PC2700 DDR 333 MHz (2 slots) 2:1 interleave |
|
| Standard | 1024 MB | (2 x 512 MB) | |
| 2048 MB | (4 x 512 MB) | ||
| Maximum | 16 GB max (using optional 333 MHz PC2700 DDR SDRAM) | ||
| 8 GB max (using optional 400 MHz PC3200 DDR SDRAM) | |||
| NOTE:
Memory must be installed in pairs. NOTE: PC2700 and PC3200 memory should not be mixed within the server blade and is not an HP supported configuration. |
|||
|
|
|||
| Network Adapter | Three (3) network adapters total: |
| Two (2) NC7781 PCI-X Gigabit NICs (on a mezzanine card) with WOL and PXE | |
| One 10/100T NIC (embedded) dedicated to iLO management | |
|
|
|
| Expansion Slots |
No PCI slots; all features are integrated. |
| Two (2) USB 1.1 ports, one (1) video port, one (1) iLO port and one (1) serial port | |
| Two (2) Local I/O cables ship with each server blade enclosure with enhanced backplane components (281404-B22 and 243564-B22) | |
| NOTE: Tested USB devices (keyboard, mouse, floppy) are listed in options section below. | |
|
|
|
| Integrated Manageability |
Integrated Lights-Out (iLO) Management Advanced (ASIC on the system board) |
|
|
|
| Internal Storage | Hard Drives | None ship standard |
|
|
||
| Maximum Internal Storage | 120GB (2 x 60GB small form factor ATA, 5,400 rpm non-hot plug hard drives) |
| 292GB (2 x 146GB small form factor SAS, 10,000 rpm non-hot plug hard drives) | |
|
|
|
| Graphics | Integrated ATI Rage XL Video Controller with 8 MB SDRAM Video Memory |
|
|
|
| Graphics Resolution Supported | Resolution Color Depths | Depths 1280 x 1024, 64k, 256,16
1024 x 768, 16.7M, 64k, 256, 16 800 x 600, 16.7M, 64k, 256, 16 640 x 480, 16.7M, 64k, 256, 16 |
|
|
||
| Fibre Channel on the HP ProLiant
BL35p server blade |
Two optional fibre channel adapters are supported by the HP ProLiant
BL35p. Both adapters are mezzanine circuit boards which connect directly
to the server blade system board. These optional fiber channel adapters
are available via option kits and must be ordered separately.
NOTE: Fibre Channel connectivity is not available on the HP ProLiant BL35p SAS models. |
|
|
|
| Compatible SAN |
HP ProLiant BL35p server blades are optimized for StorageWorks arrays:
HP ProLiant BL35p server blades are compatible with select 3rd party SANs. Please refer to blade storage website for details: http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/storage.html |
|
|
|
|
Insight Control Environment for BladeSystem |
Starting July 9, 2007, HP Insight Control management suites and most HP ProLiant Essentials will include one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. From more information about this service, please visit: http://www.hp.com/services/insight. Insight Control Environment for BladeSystem delivers foundation management for HP BladeSystem lifecycles, including hardware resource deployment, health monitoring, software version control, performance monitoring, vulnerability scanning and patch management. Installs and licenses the following components by default using a wizard-based integrated installer:
Additional ProLiant Essentials software and management tools included on the Insight Control Management DVD can be installed manually.
NOTE: Server Migration Pack - Physical
to ProLiant Edition can be installed from the SMP-P2P CD included in the
Insight Control Management media kit. |
||
|
|
|||
|
ProLiant Essentials Foundation Pack Software for the ProLiant BL Server |
HP Systems Insight Manager | HP Systems Insight Manager (HP
SIM) provides a unified, secure and extensible environment to centrally
manage servers, storage and other infrastructure devices across multiple
operating system platforms.
Through a single management view, HP SIM provides core management services that include device discovery and identification, event views, health monitoring, inventory data collection, software version control and reporting. HP SIM is built on industry standards and is extensible with value-added ProLiant Essentials, Integrity Essentials and Storage Essentials software to meet individual management needs. For more details on HP SIM visit http://www.hp.com/go/hpsim. HP SIM provides organizations with the following benefits:
|
|
| ProLiant Essentials Rapid Deployment Pack | Rapid Deployment Pack (RDP) is an automated deployment and provisioning solution for all ProLiant servers. RDP includes the Altiris Deployment Solution and ProLiant Integration Module featuring ProLiant server pre-configured events for OS installation, and optimized software drivers, firmware and management agents. Every RDP CD includes 10-node trial licenses for evaluation purposes. RDP requires a license for each server deployed and is available for purchase with blade servers. For more information, visit http://www.hp.com/servers/rdp. | ||
| ProLiant Essentials Performance Management Pack | Performance Management Pack (offered exclusively through the Insight Control suites) - a performance management solution that identifies and explains hardware performance bottlenecks on ProLiant servers and attached options enabling users to better utilize their valuable resources | ||
| Virtual Machine Management Pack | Virtual Machine Management Pack - provides central management and control of virtual machines from Microsoft and VMware. Integrated approach provides the ability to manage both physical and virtual resources from a single management console. | ||
| Vulnerability and Patch Management Pack | Vulnerability and Patch Management Pack (offered exclusively through the Insight Control suites) - identifies and remediates software security vulnerabilities due to missing patches as well operating system configurations that can be exploited by viruses, worms, and other blended threats. | ||
| Insight Management Agents | Insight Management Agents should
be installed on all HP servers to present system instrumentation, health
and configuration information into HP Systems Insight Manager and the HP
System Management Homepage. The HP System Management Homepage aggregates
systems data from Insight Management Agents and other HP management tools,
providing a consolidated browser-based interface for managing individual
servers,
Insight Management Agents and The HP System Management Homepage are included on ProLiant Support Packs, and can also be installed using the server profiles provided with the ProLiant Essentials Rapid Deployment Pack. For additional information about the Management Agents and the HP System Management Homepage please visit the management Web site at http://www.hp.com/servers/manage |
||
| Subscriber's Choice | Subscriber's Choice Driver and
Support Alerts/Notifications is a web-based email subscription service that
provides software and driver change notifications for ProLiant products.
Sign up at http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis. |
||
| ROMPaq, support software, and
configuration utilities |
The latest drivers and firmware fully optimized and tested for your ProLiant server and options, available on the RDP Media kit, SmartStart or downloadable from Software and Drivers download pages, linked from the SmartStart website at http://www.hp.com/go/support. | ||
| NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials | |||
|
|
|||
| Optional ProLiant Essentials Value Packs |
Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs:
Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. |
|
|
|
| Optional Remote Management Packs |
NOTE: Flexible and volume quantity license
kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. |
|
|
|
| SmartStart | SmartStart is a tool that simplifies
single server setup, providing a rapid way to deploy reliable and consistent
server configurations. To obtain a copy of SmartStart for your blade server,
redeem the coupon that is included with your Blade server or order your
copy from the SmartStart web site. For more information, please visit the
SmartStart Web site at http://www.hp.com/servers/smartstart. SmartStart version supported (minimum): SmartStart 7.20 |
|
|
|
| OS Support:
Dual-Core 1.8 GHz, 2.0 GHz, 2.2 and 2.4 GHz models |
Microsoft Windows 2000 Server (licensed by core) |
|
NOTE: For a complete and up-to-date
listing of supported OSs and versions, please visit our OS Support Matrix
at: http://www.hp.com/go/supportos. | |
| | |
| Supported Software Offerings |
VMware Virtualization Software |
| NOTE: For more information on HP Certified and Supported HP ProLiant Servers, please visit the VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html | |
|
|
|
| Intelligent Manageability |
Integrated Lights-Out (iLO) Advanced Pack |
NOTE: For more information on iLO Advanced visit the website: http://www.hp.com/servers/ilo/ |
|
| Automatic Server Recovery-2
(ASR-2) HP Systems Insight Manager Redundant ROM Remote Flash ROM ROM Based Setup Utility (RBSU) Advanced Configuration and Power Interface Specification Ready (ACPI) Server and Interconnect Switch Health Logs Redundant Power Supply Utility Pre-Failure Warranty (covers processors, as well as SCSI hard drives and memory) Integrated Management Log (IML) Network adapter teaming set-up utility |
|
|
|
|
| Availability | Dual-Port Fibre Channel Mezzanine Card for redundant SAN connections Redundant ROM on each server blade ECC Memory Network adapter teaming (network fault tolerance, transmit load balancing, switch-assisted load balancing) |
|
|
|
| Security | Power-on password Administrator's password Integrated Lights-Out provides user authentication via directory services or 12 customizable user accounts Integration Lights-Out supports SSH and SSL encryption Integrated Lights-Out can be disabled via a Global Setting |
|
|
|
| Factory Express Portfolio for Servers and Storage | HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
|
|
|
| HP Enterprise Configurator | The HP eCo-Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. |
|
|
|
| Service and Support |
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of resellers and service providers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. NOTE: Server Blade Limited Warranty
includes 3 year Parts, 3 year Labor, 3-year on-site support. This warranty
supports the HP ProLiant BL20p, HP ProLiant BL25p, HP ProLiant BL40p and
HP ProLiant BL45p Server Blades. The HP Care Pack service part numbers below for ProLiant BL p-Class server blades, cover the server blade and all HP branded hardware options qualified for the server, purchased at the same time or afterwards, internal to the server HP Care Pack services for HP BladeSystem p-Class server blade enclosure covers the enclosure including patch panels, HP supported Ethernet interconnects, power enclosure with power supplies and power distribution. HP services provide continuous care and support expertise with committed response designed to meet your IT and business needs. To fully capitalizing on your HP BladeSystem servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a HP BadeSystem server support offer to help you speedily deploy and maximize system uptime. Enhanced Care - Minimum recommended service support offer designed to ensure customers have access to expert assistance, whenever they need it.
Continuance Care - Recommended service delivering cost-effective support options designed to extend HP Services committed response and guaranteed fix times, designed to speed problem identification and resolution.
Total Care - Highest HP Support service level recommend to help increase IT performance and availability with comprehensive, integrated hardware and software services
Deployment Services - HP Installation and Start Up services designed to take time, risk, and worry out of the deployment of HP BladeSystem servers - and free customers IT support staff to focus on what they do best, their business.
For a complete listing of service offerings
and information visit: |
|
|
Models
| Dual-Core Models | ||
| ProLiant BL35p
2.4GHz-1MB, DC, 2GB, SAS (2P) 406024-B21 |
Processor(s) | Two (2) Dual-Core AMD Opteron™ 200 Series processors Model 280 2.4 GHz (68 Watts) standard |
| Cache Memory | 1MB Level 2 writeback per core | |
| Memory | 2048 MB (standard) of PC3200
DDR SDRAM 400 MHz 8 GB (maximum) of PC3200 DDR SDRAM 400 MHz 16 GB (maximum) of PC2700 DDR SDRAM 333 MHz 2-way interleaved, 4 DIMM slots |
|
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (on a mezzanine card) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Storage Controller | Internal 4 Port SAS HBA (on a mezzanine card) supports RAID 0 or 1 | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 292GB maximum (with optional non-hot plug SAS hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-Class Blade Sleeve. Blade sleeve supports 1 or 2 BL30p and BL35p blades, or any combination of BL30p and BL35p blades. Blade sleeve plugs vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure | |
|
|
||
| ProLiant BL35p
2.2GHz-1MB, DC, 2GB, SAS (2P) 395222-B21 |
Processor(s) | Two (2) Dual-Core AMD Opteron™ 200 Series processors Model 275 2.2 GHz (68 Watts) standard |
| Cache Memory | 1MB Level 2 writeback per core | |
| Memory | 2048 MB (standard) of PC3200
DDR SDRAM 400 MHz 8 GB (maximum) of PC3200 DDR SDRAM 400 MHz 16 GB (maximum) of PC2700 DDR SDRAM 333 MHz 2-way interleaved, 4 DIMM slots |
|
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (on a mezzanine card) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Storage Controller | Internal 4 Port SAS HBA (on a mezzanine card) supports RAID 0 or 1 | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 292GB maximum (with optional non-hot plug SAS hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-Class Blade Sleeve. Blade sleeve supports 1 or 2 BL30p and BL35p blades, or any combination of BL30p and BL35p blades. Blade sleeve plugs vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure | |
|
|
||
|
ProLiant BL35p 1.8GHz-1MB, DC, 1GB, SAS (1P) |
Processor(s) | One (1) Dual-Core AMD Opteron™ processor Model 265 1.8 GHz (68 Watts) standard (up to 2 supported) |
| Cache Memory | 1MB Level 2 writeback per core | |
| Memory | 1024 MB (standard) of PC3200
DDR SDRAM 400 MHz 8 GB (maximum) of PC3200 DDR SDRAM 400 MHz 16 GB (maximum) of PC2700 DDR SDRAM 333 MHz 2-way interleaved, 4 DIMM slots |
|
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (on a mezzanine card) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Storage Controller | Internal 4 Port SAS HBA (on a mezzanine card) supports RAID 0 or 1 | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 292GB maximum (with optional non-hot plug SAS hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-Class Blade Sleeve. Blade sleeve supports 1 or 2 BL30p and BL35p blades, or any combination of BL30p and BL35p blades. Blade sleeve plugs vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure | |
|
|
||
|
ProLiant BL35p 2.4GHz-1MB, DC, 2GB, (2P) |
Processor(s) | Two (2) Dual-Core AMD Opteron™ 200 Series processors Model 280 2.4 GHz (68 Watts) standard |
| Cache Memory | 1MB Level 2 writeback per core | |
| Memory | 2048 MB (standard) of PC3200
DDR SDRAM 400 MHz 8 GB (maximum) of PC3200 DDR SDRAM 400 MHz 16 GB (maximum) of PC2700 DDR SDRAM 333 MHz 2-way interleaved, 4 DIMM slots |
|
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (on a mezzanine card) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120GB maximum (with optional non-hot plug ATA hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-Class Blade Sleeve. Blade sleeve supports 1 or 2 BL30p and BL35p blades, or any combination of BL30p and BL35p blades. Blade sleeve plugs vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure | |
|
|
||
|
ProLiant BL35p 2.2GHz-1MB, DC, 2GB (2P) |
Processor(s) | Two (2) Dual-Core AMD Opteron™ processors Model 275 2.2 GHz (68 Watts) standard |
| Cache Memory | 1MB Level 2 writeback per core | |
| Memory | 2048 MB
(standard) of PC3200 DDR
SDRAM 400 MHz 8 GB (maximum) of PC3200 DDR SDRAM 400 MHz 16 GB (maximum) of PC2700 DDR SDRAM 333 MHz 2-way interleaved, 4 DIMM slots |
|
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (on a mezzanine card) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120GB maximum (with optional non-hot plug ATA hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-Class Blade Sleeve. Blade sleeve supports 1 or 2 BL30p and BL35p blades, or any combination of BL30p and BL35p blades. Blade sleeve plugs vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure | |
|
|
||
|
ProLiant BL35p 2.0GHz-1MB, DC, 2GB (2P) |
Processor(s) | Two (2) Dual-Core AMD Opteron™ processors Model 270 2.0 GHz (68 Watts) standard |
| Cache Memory | 1MB Level 2 writeback per core | |
| Memory | 2048 MB
(standard) of PC3200 DDR
SDRAM 400 MHz 8 GB (maximum) of PC3200 DDR SDRAM 400 MHz 16 GB (maximum) of PC2700 DDR SDRAM 333 MHz 2-way interleaved, 4 DIMM slots |
|
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (on a mezzanine card) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120GB maximum (with optional non-hot plug ATA hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-Class Blade Sleeve. Blade sleeve supports 1 or 2 BL30p and BL35p blades, or any combination of BL30p and BL35p blades. Blade sleeve plugs vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure | |
|
|
||
|
ProLiant BL35p 1.8GHz-1MB, DC, 1GB (1P) |
Processor(s) | One (1) Dual-Core AMD Opteron™ processor Model 265 1.8 GHz (68 Watts) standard (up to 2 supported) |
| Cache Memory | 1MB Level 2 writeback per core | |
| Memory | 1024 MB (standard) of PC3200
DDR SDRAM 400 MHz 8 GB (maximum) of PC3200 DDR SDRAM 400 MHz 16 GB (maximum) of PC2700 DDR SDRAM 333 MHz 2-way interleaved, 4 DIMM slots |
|
| Network Adapter | Two (2) NC7781 PCI-X Gigabit
NICs (on a mezzanine card) with WOL and PXE One (1) 10/100T NIC (embedded) dedicated to iLO management |
|
| Hard Drives | None ship standard | |
| Internal Storage | Up to 120GB maximum (with optional non-hot plug ATA hard drives) | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-Class Blade Sleeve. Blade sleeve supports 1 or 2 BL30p and BL35p blades, or any combination of BL30p and BL35p blades. Blade sleeve plugs vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure |
|
|
Configuration Information - Factory Integrated Models
|
NOTE: HP does not allow factory integration of options into standard
models listed above. |
||
| Step 1: Base Server Blade Configuration | ||
| Model | HP ProLiant BL35p
Configurable Model CTO Blade |
382734-405
|
| Factory Integrated
Model ships with: - One embedded 10/100T NIC for iLO - Integrated Lights-Out (iLO) Management with Advanced Pack features |
||
| HP ProLiant BL35p SAS Configurable Model CTO Blade |
398605-405
|
|
|
Factory Integrated Model ships with: |
||
|
|
||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processor | Dual-Core AMD Opteron™
Model 280 2.4 GHz/68W FIO ALL NOTE: If dual processor configurations are desired, select one 399602-L21 and one 399602-B21. |
399602-L21
|
| Dual-Core AMD Opteron
Model 275 2.2 GHz/68W FIO ALL NOTE: If dual processor configurations are desired, select one 392447-L21 and one 392447-B21. |
392447-L21
|
|
| Dual-Core AMD Opteron
Model 270 2.0 GHz/68W FIO ALL NOTE: If dual processor configurations are desired, select one 392449-L21 and one 392449-B21. |
392449-L21
|
|
| Dual-Core AMD Opteron
Model 265 1.8 GHz/68W FIO ALL NOTE: If dual processor configurations are desired, select one 392451-L21 and one 392451-B21. |
392451-L21
|
|
|
|
||
| Memory | For 1 GB Total Memory: | |
| 1 GB PC3200 DDR SDRAM DIMM Memory Kit (2 x 512 MB) |
376638-B21
|
|
| For 2 GB Total Memory, choose A or B: | ||
| A) 2 GB PC3200 DDR SDRAM DIMM Memory Kit (2 x 1 GB) |
376639-B21
|
|
| B) 2 x 1 GB PC3200 DDR SDRAM DIMM Memory Kit (2 x 512 MB) |
376638-B21
|
|
| For 4 GB Total Memory, choose A or B: | ||
| A) 4 GB PC3200 DDR SDRAM DIMM Memory Kit (2 x 2 GB) |
379300-B21
|
|
| B) 2 x 2 GB PC3200 DDR SDRAM DIMM Memory Kit (2 x 1 GB) |
376639-B21
|
|
| For 8 GB Total Memory, choose A or B: | ||
| A) 8 GB PC2700 DDR SDRAM DIMM Memory Kit (2 x 4 GB) |
395409-B21 |
|
| B) 2 x 4 GB PC3200 DDR SDRAM DIMM Memory Kit (2 x 2 GB) |
379300-B21 |
|
| For 16 GB Total Memory: | ||
| 2 x 8 GB PC2700 DDR SDRAM DIMM Memory Kit (2 x 4 GB) |
395409-B21
|
|
| NOTE: Two-way
interleaving memory is enabled when an identical pair of DIMMs is installed. NOTE: Maximum performance in a two processor (2P) server blade is achieved when Option B memory configurations are utilized. |
||
|
|
||
| Communications NOTE: Must select one |
HP ProLiant BL25/35/45p NIC Mezz FIO Base |
382850-B21
|
| Or upgrade to: | ||
| HP ProLiant BL25p/35p/45p Dual NC370i Multifunction Network Adapter |
384043-B21
|
|
| NOTE: NC370i adapter supports iSCSI, RDMA, TOE with applicable licenses. | ||
|
NOTE: Accelerated iSCSI is not yet supported for Linux environments, and RDMA is not yet supported for Windows or Linux environments. Future support is planned for both. |
|
|
| NOTE: A minimum of 1 GB of memory per port is required for NC370x adapters, with a maximum of two NC370x ports permitted in a server. | ||
|
|
||
| Step 3: Choose Additional Options for Factory Integration | ||
| Hard Drive | SAS Non-Hot Plug | |
| HP 36GB 3G SAS 10K NHP SFF HDD
|
384038-B21
|
|
| HP 72GB 3G SAS 10K NHP SFF HDD |
384141-B21
|
|
| HP 146GB 3G SAS 10K NHP SFF HDD |
436649-B21
|
|
| NOTE: Supported on SAS models only | ||
| ATA Non-Hot Plug | ||
| HP BL30p/BL35p 60G ATA HDD ALL |
354052-B21
|
|
| Fibre Channel Option | Emulex-based BL25/30/35/45p Dual
Port Fibre Channel HBA NOTE: SFPs for use with pass through SAN switches not included with the Emulex-based Fibre Channel Mezzanine card. If SFPs required please order the SFP option kit (P/N 397577-B21) which includes 2 2Gb SFPs per option kit. |
394588-B21
|
| HP 2-2Gb SFP for Fibre Channel
pass through kit NOTE: Must select if SFP for use with pass through SAN switches is required when ordering Emulex-based Fibre Channel Mezzanine card for HP p-Class BladeSystem (p/N 394757-B21. |
397577-B21
|
|
| BL30p/BL35p Dual Port Fibre Channel
Adapter NOTE: The BL30p/BL35p Dual Port Fibre Channel Adapter is QLogic based. |
354054-B21
|
|
| NOTE: For additional
options, including HP BladeSystem p-Class blade sleeves, enhanced server
blade enclosure, interconnect options and power subsystem options please
refer to the "Options" section below. NOTE: Fibre Channel connectivity is not available on the HP ProLiant BL35p SAS model (P/N 398605-405). |
||
| NOTE: For additional options, please refer to the "Options" section below. | ||
|
|
Options
| NOTE: Some options may not be factory integratable. Please contact your local sales representative for additional information. | ||
| Unique Options | HP BladeSystem p-Class Blade Sleeve Kit |
354101-B21 |
| NOTE: Each blade sleeve supports one or two HP ProLiant BL30p/HP ProLiant BL35p server blades. HP ProLiant BL30p and BL35p server blades may be mixed within the blade sleeve. | ||
|
|
||
|
ProLiant Essentials Value Pack Software |
Insight Control Environment for BladeSystem | |
| HP Insight Control Environment
for BladeSystem, No Media 1-Server License including 1 year of 24x7 Technical
Support and Updates NOTE: Contains 1 license for each of RDP, PMP, VPM, IPM and iLO Select. Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12631_na/12631_na.html |
453484-B21
|
|
| ProLiant Essentials Rapid Deployment Pack | ||
| ProLiant Essentials Rapid Deployment
Pack No Media 1-Server License including 1 year of 24x7 Technical Support
and Updates NOTE: This license allows 1 server to be deployed and managed via RDP. |
452151-B21
|
|
| NOTE: For additional ProLiant Essentials Rapid Deployment Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.html | ||
| ProLiant Essentials Server Migration Pack | ||
| ProLiant Essentials Server Migration
Pack, Single-Migration License NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation. NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005. |
435663-B21
|
|
| NOTE: For additional ProLiant Server Migration Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_na/12328_na.html | ||
| Server Migration Pack - P2P | ||
| ProLiant Essentials Server Migration
Pack - P2P Edition, 1- Migration License, - License Only, No Media NOTE: This license allows 1 migration. Contains one license with a unique license activation key and documentation NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12467_na/12467_na.html |
417435-B21
|
|
| ProLiant Essentials Virtual Machine Management Pack | ||
| ProLiant Essentials Virtual Machine
Management Pack, No Media, 1-Server License, including 1 year of 24x7 Technical
Support and Updates NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
452153-B21
|
|
| NOTE: For additional ProLiant Virtual Machine Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_na/12328_na.html | ||
| NOTE: Flexible
and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. |
||
|
|
||
|
Remote Management |
Insight Control Environment for BladeSystem | |
| HP Insight Control Environment
for BladeSystem, No Media 1-Server License including 1 year of 24x7 Technical
Support and Updates NOTE: Contains 1 license for each of RDP, PMP, VPM, IPM and iLO Select. Includes one year of 24 x 7 HP Software Technical Support and Update Service |
453484-B21
|
|
|
|
||
| HP Insight Control Linux Edition for HP BladeSystem | HP Insight Control Linux Edition
1.6 -No Media, 1-Server License, including 1 year of 24x7 Technical Support
and Updates NOTE: This license allows one (1) server blade to be deployed and managed via HP Insight Control Linux Edition. |
452155-B21
|
| HP Insight Control Linux Edition
1.6,No Media, 8-Server License, including 1 year of 24x7 Technical Support
and Updates NOTE: This license allows eight (8) server blades to be deployed and managed via HP Insight Control Linux Edition. |
452156-B21
|
|
| HP Insight Control Linux Edition
1.6, No Media, Flexible-Quantity License, including 1 year of 24x7 Technical
Support and Updates NOTE: For use with multiple servers (minimum of 5). This part number allows you to specify the license quantity. When ordering this part number, the quantity ordered will be the number of licenses embedded in a single activation key. A single kit containing that key is then delivered to you. |
452157-B21
|
|
|
|
||
| Processor | Dual-Core AMD Opteron™ processor Model 280 2.4 GHz/1M/68W Processor Option Kit |
399602-B21
|
| Dual-Core AMD Opteron processor Model 275 2.2 GHz/1M/68W Processor Option Kit |
392447-B21
|
|
| Dual-Core AMD Opteron processor Model 270 2.0 GHz/1M/68W Processor Option Kit |
392449-B21
|
|
| Dual-Core AMD Opteron processor Model 265 1.8 GHz/1M/68W Processor Option Kit |
392451-B21
|
|
| Single-Core AMD Opteron processor Model 250 2.4 GHz/1M/68W Processor Option Kit |
381883-B21
|
|
|
|
||
| Memory | 8 GB PC2700 DDR SDRAM DIMM Memory
Kit (2 x 4 GB) NOTE: Must install in pairs |
395409-B21
|
| 4 GB PC3200 DDR SDRAM DIMM Memory
Kit (2 x 2 GB) NOTE: Must install in pairs |
379300-B21
|
|
| 2 GB PC3200 DDR SDRAM DIMM Memory
Kit (2 x 1 GB) NOTE: Must install in pairs |
376639-B21
|
|
| 1 GB PC3200 DDR SDRAM DIMM Memory
Kit (2 x 512 MB) NOTE: Must install in pairs |
376638-B21
|
|
|
|
||
| Hard Drive | SAS Non-Hot Plug | |
| HP 36GB 3G SAS 10K NHP SFF HDD |
384038-B21
|
|
| HP 72GB 3G SAS 10K NHP SFF HDD |
384141-B21
|
|
| HP 146GB 3G SAS 10K NHP SFF HDD |
436649-B21
|
|
| NOTE: Supported on SAS models only | ||
| ATA Non-Hot Plug | ||
| HP BL30p/BL35p 60G ATA HDD ALL |
354052-B21
|
|
|
|
||
| Communications | Multifunction NIC with support for iSCSI, RDMA, TOE: | |
| HP ProLiant BL25p/35p/45p Dual NC370i Multifunction Network Adapter |
384043-B21
|
|
|
NOTE: NC370i adapter supports iSCSI, RDMA, TOE with applicable licenses. |
||
| NOTE: Accelerated
iSCSI is not yet supported for Linux environments, and RDMA is not yet supported
for Linux environments. |
||
|
|
||
| ProLiant BL30p/BL35p Fibre Channel Adapter | Emulex-based BL25/30/35/45p Dual Port Fibre Channel HBA |
394588-B21
|
| Dual-Port Fibre Channel Adapter
(2Gb) Kit (option) for HP ProLiant BL30p or HP ProLiant BL35p server blades NOTE: This Fibre-Channel adapter is QLogic-based NOTE: When using this adapter, Patch Panel 2, CGESM, or a GbE2 Interconnect Switch Kit (with Storage Connectivity Kit) must be used to provide pass through of the Fibre Channel signals. |
354054-B21
|
|
| NOTE:
For additional information on HP p-Class Interconnect Kits please visit:
http://h18000.www1.hp.com/products/quickspecs/12331_na/12331_na.html NOTE: Fibre Channel connectivity is not available on the HP ProLiant BL35p SAS models. |
||
|
|
||
| HP BladeSystem p-Class Other Options | HP BladeSystem p-Class Diagnostic
Station NOTE: The Diagnostic Station allows access to the HP ProLiant p-Class server blades and the BL p-Class interconnect switch outside of the server blade enclosure. The option provides power and a data interface so that "offline" upgrade and diagnostic functions may be performed. |
230743-B21
|
|
|
||
|
Tape Libraries |
HP StorageWorks MSL2024 Tape
Library |
|
| HP StorageWorks MSL2024 1 Ultrium
960 Drive Library |
AG115A | |
| HP StorageWorks MSL2024 1 Ultrium
960 4GB FC Library |
AG326B | |
| HP StorageWorks MSL2024 1 Ultrium
920 Drive Library |
AH169A | |
| HP StorageWorks MSL2024 2 Ultrium
920 Drive Library |
AH170A | |
| HP StorageWorks MSL2024 1 Ultrium
448 Drive Library |
AG116A | |
| HP StorageWorks MSL2024 2 Ultrium
448 Drive Library |
AG117A | |
| HP StorageWorks MSL4048 Tape
Library |
||
| HP StorageWorks MSL4048 1 Ultrium
448 Drive Library |
AG320A | |
| HP StorageWorks MSL4048 2 Ultrium
448 Drive Library |
AG321A | |
| HP StorageWorks MSL4048 1 Ultrium
960 Drive Library |
AG322A | |
| HP StorageWorks MSL4048 1 Ultrium
960 4GB FC Library |
AG324B | |
| HP StorageWorks MSL4048 2 Ultrium
960 Drive Library |
AG323A | |
| HP StorageWorks MSL4048 2 Ultrium
960 4GB FC Library |
AG325B | |
| HP StorageWorks MSL4048 1 Ultrium
920 Tape Library |
AH171A | |
| HP StorageWorks MSL4048 2 Ultrium 920 Tape Library | AH172A | |
| HP StorageWorks MSL6000 Tape Library | ||
| Ultrium 960 technology | ||
| HP StorageWorks MSL6030 1 Ultrium
960 Dr LVDS Library |
AD606B | |
| HP StorageWorks MSL6030 1 Ultrium
960 Dr FC Library |
AD608B | |
| HP StorageWorks MSL6030 2 Ultrium
960 Dr LVDS Library |
AD607B |
|
| HP StorageWorks MSL6030 2 Ultrium 960 Dr FC Library | AD609B | |
| Ultrium 460 technology | ||
| HP StorageWorks MSL6030 1 Ultrium
460 Dr LVDS Library |
AD598B | |
| HP StorageWorks MSL6030 1 Ultrium
460 Dr FC Library |
AD600B | |
| HP StorageWorks MSL6030 2 Ultrium
460 Dr LVDS Library |
AD599B | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr FC Library | AD601B | |
| NOTE: Please reference the MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs | ||
| HP StorageWorks Virtual Library Systems | ||
| HP Virtual Library Systems 300 Base Unit | AH138A | |
| HP StorageWorks 1002i 2TB Virtual Library System | AG124A | |
| HP StorageWorks 6105 Virtual Library
System |
AF728A | |
| HP StorageWorks 6510 Virtual Library
System |
AF729A | |
| HP StorageWorks 6840 Virtual Library System | AG051A | |
| HP StorageWorks 6109 Virtual Library System | AG167A | |
| HP StorageWorks 6518 Virtual Library System | AG168A | |
| HP StorageWorks 6870 Virtual Library System | AG169A | |
| NOTE: Please reference the Virtual Library Systems QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution. Reference current compatibility information at http://www.hp.com/go/ebs | ||
|
|
||
| HP StorageWorks Modular Smart Array 1000 | HP StorageWorks Modular Smart Array 1000 |
201723-B22 |
| NOTE: Please see
the StorageWorks Modular Smart Array 1000 QuickSpecs for additional options
and configuration information at: http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html |
||
|
|
||
| Cluster Options | ProLiant Cluster Starter kit |
364023-B22
|
| NOTE:
For additional information regarding the HP ProLiant Cluster Starter
Kit please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11935_na/11935_na.html |
||
| ProLiant Cluster HA/F200 for the
Entry Level SAN |
364026-B22 |
|
| NOTE: For additional
information regarding the ProLiant Cluster for Entry Level SAN please see
the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11932_na/11932_na.html |
||
|
ProLiant Cluster HA/F500 for the Enterprise SAN |
364024-B21
|
|
|
NOTE: For additional information regarding
the ProLiant Cluster HA/F500 for Enterprise SAN please see the following
QuickSpecs at: |
||
|
NOTE: For configuration/certification options for the HP Parallel Database Cluster for Oracle RAC please go to: http://www.hp.com/solutions/highavailability/oracle |
||
| HP Serviceguard for Linux, A.11.18 (single license version - Red Hat EL 4&5, SUSE SLES9&10) |
305199-B27 |
|
| HP Serviceguard for Linux A.11.16 for SUSE SLES9 & 10 and Red Hat EL 3 & 4 (single license version) |
307754-B27 |
|
| HP Serviceguard for Linux and
Red Hat Global File System - 1 year subscription |
T2798AA#001 |
|
| HP Serviceguard for Linux and
Red Hat Global File System - 3 years subscription |
T2798AA#003
|
|
| NOTE: For additional
information regarding HP Serviceguard for Linux, please see the following
QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html |
||
| NOTE: For configuration/certification options for HP Serviceguard for Linux please go to: http://www.hp.com/info/sglx | ||
|
|
||
| USB Options | USB Optical Scroll Mouse (Carbonite) | DD441B |
| HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver) | DC172B | |
| HP USB 04 Standard Keyboard | DT528A#ABA | |
| USB 2.0 4-port HUB | DG954AA | |
| NOTE: USB 2.0 devices will operate at USB 1.1 speeds. | ||
|
|
||
| HP Rack 5000 Series (Graphite Carbonite) |
HP 5642 Rack - Unassembled |
358254-B21
|
| NOTE:
Please see the HP Rack 5642 QuickSpecs for additional part numbers and Technical
Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.html NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower |
||
|
|
||
|
HP Rack 10000 G2 Series (Graphite Metallic) |
10642 G2 (42U) Rack Cabinet -
Pallet |
AF001A
|
| 10642 G2 (42U) Rack Cabinet -
Shock Pallet |
AF002A
|
|
| 10642 G2 (42U) Rack Cabinet -
Crated |
AF003A
|
|
| 10642 G2 (42U) Rack Cabinet, with
Extension - Shock Pallet |
AF004A
|
|
| 10636 G2 (36U) Rack Cabinet -
Shock Pallet |
AF011A
|
|
| 10636 G2 (36U) Rack Cabinet -
Crated |
AF012A
|
|
| 10636 G2 (36U) Rack Cabinet, with
Extension - Shock Pallet |
AF013A
|
|
| 10636 G2 (36U) Rack Cabinet, without
door - Shock Pallet |
AF014A
|
|
| 10622 G2 (22U) Rack Cabinet -
Shock Pallet |
AF022A
|
|
| 10842 G2 (42U) 800mm Wide Rack
Cabinet - Pallet |
AF041A
|
|
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Shock Pallet |
AF042A
|
|
| 10647 G2 (47U) Rack Cabinet - Pallet |
AF031A
|
|
| NOTE: Please see
the Rack 10000 G2 QuickSpecs for additional part numbers and Technical Specifications
such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. |
||
|
|
||
|
HP Rack 10000 Series (Graphite Metallic) |
10642 (42U) Infrastructure Rack
(Low Voltage) |
379006-001
|
| 10642 (42U) Infrastructure Rack
(High Voltage) |
379005-001
|
|
| HP S10614 (14U) Rack Cabinet -
Shock Pallet |
292302-B22
|
|
| NOTE: xxxxxx-B22
(shock pallet) used to ship racks with equipment installed (by custom systems,
VARs and Channels). xxxxxx-B23 (crated) used for air shipments of empty
racks. NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. |
||
| NOTE: Please see
the Rack 10000 QuickSpecs for additional part number and Technical Specifications
such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. |
||
|
|
||
|
Monitors and Keyboards |
TFT7210R Rack Mounted 17" Monitor |
348373-B21
|
| TFT7600 Rackmount Keyboard Monitor |
AG052A
|
|
| 1U Rackmount Keyboard with USB |
AG072A
|
|
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
|
||
|
HP KVM Switch Options |
4x1x16 IP Console Switch with Virtual Media |
AF602A
|
| 2x1x16 IP Console Switch with Virtual Media |
AF601A
|
|
| 2x16 Server Console Switch with Virtual Media |
AF600A
|
|
| Server Console Switch (KVM), 0 x 1 x 8 |
336044-B21
|
|
| Server Console Switch (KVM), 0
x 2 x 16 port |
336045-B21
|
|
| BladeSystem p-Class KVM Interface
Adapter |
AF100A
|
|
| Serial Interface adapter - 1 Pack with power supply |
373035-B21
|
|
| NOTE: Cat5e cables are required to connect Interface Adapters to Consoles Switches. Cat52e cables can be found at the following URL: http://www.hp.com/go/kvm | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm | ||
|
|
||
|
HP Serial Console Server Options |
HP 16 Port Serial Console Server |
AF101A
|
| HP 48 Port Serial Console Server |
AF102A
|
|
| Serial Adapter, RJ45-DB9 DCE Female,
1 Pack |
AF103A
|
|
| Serial Adapter, RJ45-DB9 DCE Female,
8 Pack |
AF110A
|
|
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
|
Service and Support Offerings (HP Care Pack Services) |
|
|
|
Memory
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
|
DIMM installation guidelines:
|
|
HP ProLiant BL35p Server Blade (1P model) |
|
Standard Memory Standard Memory Replaced with Optional Memory Up to 8192 MB of PC2700 DDR SDRAM DIMM memory is available with the removal of standard memory and the installation of optional PC2700 SDRAM DDR DIMM memory expansion kits. NOTE: Maximum memory configuration with one processor installed using PC3200 DDR SDRAM DIMMs is 4096 MB (2 x 2048 MB), or 8192 MB using PC2700 DDR SDRAM DIMMs (2 x 4096 MB.) Second processor must be installed in order to use the 2nd bank of memory (Slots 3 and 4.) Maximum memory configuration with two processors installed using PC3200 DDR SDRAM DIMMS is 8192 MB (4 x 2048 MB), or 16384 MB using PC2700 DDR SDRAM DIMMs (4 x 4096 MB.) |
|
Memory |
Slot |
||||
|
1
|
2
|
3
|
4
|
||
|
Standard |
1024 MB |
512 MB
|
512 MB
|
Empty
|
Empty
|
| Optional |
2048 MB
|
1024 MB
|
1024 MB
|
Empty
|
Empty
|
| 4 GB PC3200 Maximum |
4096 MB
|
2048 MB
|
2048 MB
|
Empty
|
Empty
|
| 8 GB PC2700 Maximum |
8192 MB
|
4096 MB
|
4096 MB
|
Empty
|
Empty
|
|
Following are memory options available from HP: |
|
|
395409-B21 |
|
379300-B21 |
|
376639-B21 |
|
376638-B21 |
|
|
|
|
HP ProLiant BL35p Server Blade (2P model) |
|
Standard Memory Standard Memory Replaced with Optional Memory Up to 16384 MB of PC2700 DDR SDRAM DIMM memory is available
with the removal of standard memory and the installation of optional PC2700
SDRAM DDR DIMM memory expansion kits. NOTE: Maximum memory configuration with one processor installed using PC3200 DDR SDRAM DIMMs is 4096 MB (2 x 2048 MB), or 8192 MB using PC2700 DDR SDRAM DIMMs (2 x 4096 MB.) Second processor must be installed in order to use the 2nd bank of memory (Slots 3 and 4.) Maximum memory configuration with two processors installed using PC3200 DDR SDRAM DIMMS is 8192 MB (4 x 2048 MB), or 16384 MB using PC2700 DDR SDRAM DIMMs (4 x 4096 MB.) |
|
Memory |
Slot |
||||
|
1
|
2
|
3
|
4
|
||
|
Standard |
2048 MB |
512
MB
|
512
MB
|
512
MB
|
512
MB
|
| Optional |
4096
MB
|
1024
MB
|
1024
MB
|
1024
MB
|
1024
MB
|
| 8 GB PC3200 Maximum |
8192
MB
|
2048
MB
|
2048
MB
|
2048
MB
|
2048
MB
|
| 16 GB PC2700 Maximum |
16384
MB
|
4096
MB
|
4096
MB
|
4096
MB
|
4096
MB
|
|
Following are memory options available from HP: |
|
|
395409-B21 |
|
379300-B21 |
|
376639-B21 |
|
376638-B21 |
|
|
Technical Specifications
| HP ProLiant BL35p Server Blade |
Dimensions |
Height |
1.61 in (4.1 cm) |
| Depth | 25.35 in (64.4 cm) | ||
| Width | 4.72 in (12.0 cm) | ||
|
Weight |
Maximum |
8.19 lb (3.72 kg) | |
| No Drives Installed | 7.76 lb (3.52 kg) | ||
|
Temperature Range*
|
Operating |
50° to 95° F (10° to 35° C) | |
| Shipping |
-40° to 140° F (-40° to 60° C) | ||
| Storage |
-4° to 140° F (-20° to 60° C) | ||
| Maximum Wet Bulb Temperature | 86° F (-30° C) | ||
| Relative Humidity**
|
Operating |
10% to 90% | |
| Shipping |
10% to 90% | ||
| Storage |
10% to 95% | ||
| *NOTE: All temperature ranges shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit is 3,048 m (10,000 ft) or 70 Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia. | |||
| **NOTE: Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa. | |||
|
|
|||
| Tape Drives, Tape Autoloaders, & Tape Libraries | |||
|
NOTE: For an up-to-date listing of the
latest O/S Support details for each of the Tape Drives listed below, please
see the following: NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders & Tape Libraries listed below, please see the following: http://h18000.www1.hp.com/products/quickspecs/north_america/10809.html NOTE: For complete listing of tape drive offerings see http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html For recommended tape drive offerings for this ProLiant server see the following: |
|||
|
Position
Supported |
Controller
|
Controller/HBA Option Kit Part Number |
|
| HP StorageWorks Tape Libraries,
External MSL2024 (Ultrium 448, Ultrium 920 and 960-based) MSL4048 (Ultrium 448, Ultrium 920 and 960-based) MSL6000 (Ultrium 960 and 460-based) MSL6000 (SDLT 600-based) |
External
|
Please consult the EBS connectivity matrix at http://www.hp.com/go/ebs for detailed connectivity information. |
N/A
|
| HP StorageWorks Virtual Library
Systems 300 VLS 1002i VLS 6105 VLS 6109 VLS 6515 VLS 6840 VLS 6870 VLS |
External
|
Please consult the EBS connectivity matrix at http://www.hp.com/go/ebs for detailed connectivity information. |
N/A
|
|
|
|||
|
© Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. AMD, the AMD Arrow logo, AMD Opteron™, and combinations thereof, are trademarks of Advanced Micro Devices, Inc. The
only warranties for HP products and services are set forth in the express warranty
statements accompanying such products and services. Nothing herein should be construed
as constituting an additional warranty. HP shall not be liable for technical or
editorial errors or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |