Overview
|
HP BladeSystem p-Class Infrastructure
|
| At A Glance |
|
This document covers the HP BladeSystem p-Class Infrastructure only.
For more information on HP ProLiant Server Blades and HP BladeSystem p-Class
Interconnect Components please see the following QuickSpecs: HP BladeSystem solutions starts with a Server Blade Enclosure, power
enclosure, networking interconnects, HP ProLiant Server Blades, and management
tools.
NOTE: Power requirements for a HP BladeSystem p-Class-: 200V - 240V AC, 30 Amp or facility DC -48V ± 10%. |
|
|
HP BladeSystem p-Class Overview
| HP BladeSystem Overview | As server density and network
connectivity has increased traditional rack-mounted server solutions have
generated increased complexity of both server management and physical infrastructure.
HP BladeSystem is the evolution of the entire rack-mounted infrastructure. A BladeSystem aims to simplify the management, building, and maintenance of the infrastructure behind your multi-server environment. It consolidates and repackages all the supporting infrastructure elements-compute, storage, network, and power into a single platform that can accelerate the integration and optimization of your data center. With the flexibility to scale from a single enclosure holding up to 16 blades, to a rack containing 6 enclosures holding up 96 blades the p-Class infrastructure is designed to meet the needs of today's businesses. An HP BladeSystem is made up of several components:
|
|
|
|
| HP ProLiant Server Blade | Delivering best-in-class performance,
choice and reliability on Intel® Xeon™ and AMD Opteron™ processors
for Windows or Linux based systems, the HP portfolio of server blades supports
a variety of application requirements for scale-out architectures. HP offers
one-, two-, and four-processor server blades, including the widest range
of performance, and form factors, and the most processing density and performance
of any other portfolio.
For more information please see: http://h18000.www1.hp.com/products/quickspecs/division/11070.html |
|
|
|
| HP BladeSystem p-Class Enclosure |
A BladeSystem enclosure holds
up to 16 ProLiant server blades plus redundant network and storage switches.
It includes a shared, high-speed backplane for wire-once connectivity of
server blades to network, shared storage, and power.
A management module is built in to the enclosure that reports asset and inventory information and thermal, power, and protection fuse events. With hardware management integrated across the solution, one full enclosure can be managed as easily as one server. A BladeSystem enclosure provides the following benefits:
|
|
|
|
| HP BladeSystem p-Class Interconnect Options | HP also offers one of the broadest
selections of Gigabit Ethernet and Fibre Channel switches and patch panel
options in the industry to provide network, SAN/network attached storage
(NAS), and cluster connectivity.
HP BladeSystem interconnects provide:
For more information HP BladeSystem p-Class Interconnect Components, please visit: http://h18004.www1.hp.com/products/blades/components/components.html |
| | |
| HP BladeSystem p-Class Power Sub-System | The efficient design of the
BladeSystem power subsystem reduces power distribution costs and provides
power capacity for current and future server blades. Power supplies are
centralized to provide scalable, redundant power for a single enclosure
of blades up to an entire rack full. HP offers fully redundant 1U and 3U
power supply options for configurations of different sizes, supporting both
single- and three-phase power.
HP BladeSystem power subsystems provide:
|
|
|
|
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and
deployment services for HP servers and storage products. Customers can
choose how their factory solutions are built, tested, integrated, shipped
and deployed. Factory Express offers service packages for simple configuration, racking,
installation, complex configuration and design services as well as individual
factory services, such as image loading, asset tagging and custom packaging.
HP products supported through Factory Express include: a wide array of
servers and storage: HP Integrity, HP ProLiant & HP ProLiant Server
Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx,
EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express |
|
|
|
| Service and Support |
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. NOTE: Server Blade Limited Warranty
includes 3 year Parts, 3 year Labor, 3-year on-site support. This warranty
supports the HP ProLiant BL20p, HP ProLiant 25p, HP ProLiant 40 and HP
ProLiant 45p Server Blades. HP Care Pack services provide total care and support expertise with committed response designed to meet your IT and business needs. HP Care Pack services for HP BladeSystem p-Class server blade enclosure covers the enclosure including patch panels, HP supported Ethernet interconnects, power enclosure with power supplies and power distribution. To fully capitalize on your HP BladeSystem servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a HP BadeSystem server support offer to help you speedily deploy and maximize system uptime. Recommended Service - Simplify ProLiant solution implementation,
maintenance and management.
Enhanced Service - Optimize service level to increase IT performance
and availability
Installation & Start-Up service for HP BladeSystem Infrastructure
plus HP BladeSystem Enhanced Network Installation and Start-UP as per
the Customer Description and/or Data Sheet. To be delivered on a scheduled
basis 8am-5pm, M-F, excluding HP holidays. For a complete listing of service offerings
and information visit: |
|
|
Building an HP BladeSystem
|
|
|
|
|
||||||||||||||||||||||||||||
|
|
Standard Features
| HP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class Interconnects | |
| HP BladeSystem p-Class Server Blade Enclosures |
6U (10.5-inch), 19-inch wide |
| Holds up to 8 HP ProLiant server blades | |
|
10 bays per server blade enclosure 8 bays for server blades |
|
| 2 outside bays for interconnect
modules (RJ-45 Patch Panel, RJ-45 Patch Panel 2, GbE Interconnect Switch,
GbE2 Interconnect Switch or Cisco GESM Interconnect Switch) NOTE: For additional information on Interconnect Options, please visit: http://h18000.www1.hp.com/products/quickspecs/12331_div/12331_div.html |
|
| Server blades blind mate into the server blade enclosure backplane for power and data connections | |
| Server blade management module attached to the back of each HP BladeSystem p-Class 6U server blade enclosure to report events all servers and provide asset and inventory information | |
| Single physical iLO port that provides access to all server blades | |
| NOTE: HP ProLiant
HP BladeSystem p-Class server blade enclosures with enhanced backplane components
might be required depending on which HP ProLiant server blade model is selected.
http://www.hp.com/go/bladesystem/enclosure/compatibility NOTE: Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support specific HP ProLiant server blade models and provide a single, physical iLO port for the enclosure. |
|
|
|
|
| HP BladeSystem p-Class Enclosure Power Requirements |
Redundant 200V - 240V AC, 20
amp single phase for 1U enclosure Redundant 200V - 240V AC, 30 amp single-phase for North America single-phase 3U enclosure Redundant 200V - 240V AC, 32 amp single-phase for Intl single-phase 3U enclosure Redundant 208V 30amp 3-phase delta 4 wire for North America 3-phase 3U enclosure Redundant 200/380 - 240/415V 32A 3-phase Wye, 5 wire for Intl 3-phase 3U enclosure Redundant -48VDC ± 10% for direct DC Power connection |
|
|
|
| Power System and Rack Information | |
| HP BladeSystem p-Class Power System and Rack Information |
NOTE: To determine
power configuration please refer to the HP BladeSystem p-Class Overview
and Planning Whitepaper and sizing tool at http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/20p/index.html |
|
|
|
| HP BladeSystem p-Class 1U Power Enclosure |
1U (1.75-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Multi-input single phase operation. |
| HP BladeSystem p-Class 1U power
enclosure provides external, hot-plug power. Each 1U power enclosure houses
up to six hot-plug power supplies to power up to one server blade enclosure,
fully populated with BL p-Class server blades and interconnects. Please use the sizing utility to determine the power needed for each configuration http://www.hp.com/go/bladesystem/powercalculator NOTE: Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed. |
|
|
|
|
| HP BladeSystem p-Class 3U Power Enclosure |
3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Dual input single phase and three phase models available. |
| HP BladeSystem p-Class 3U power
enclosure provides external, shared hot-plug power. Each three-phase power
enclosure houses up to six hot-plug power supplies, each single-phase power
enclosure holds up to four hot-plug power supplies to power the BL p-Class
server blades and interconnects Please use the sizing utility to determine the power needed for each configuration http://www.hp.com/go/bladesystem/powercalculator |
|
| Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed. | |
|
|
|
| HP BladeSystem
p-Class Power Distribution (only required with 3U power enclosures) |
When using the HP BladeSystem 3U Power Enclosure or facility DC power, redundant -48 VDC power is distributed from the power enclosures to the server blade enclosures through the bus bar system. Hinges attach the HP BladeSystem bus bars to the rails in a rack. The bus bars swing open from the center to enable easy rear access to the server blades and network cables. Power is distributed redundantly through independent A- and B-sided bus bars. |
|
Three different power distribution solutions are available depending on the maximum number of server blade enclosures planned for the rack: |
|
|
|
| NOTE: To support a full 42U rack of HP ProLiant server blades (6 server blade enclosures), two mini bus bars are needed. | |
|
|
|
|
Power Enclosures Supported
|
Server Blade Enclosures Supported
|
Max. Rack Space Occupied
|
|
| Scalable Bus Bar |
1 or 2
|
up to 5
|
36U
|
| Mini Bus Bar |
1 or 2
|
up to 3
|
21U
|
| Power Bus Box |
1
|
1
|
9U
|
| NOTE: To support
a full 42U rack of BL p-Class server blades, use two stacked pairs of mini
bus bars. NOTE: Dual power input kit for mini bus bar option (364565-B21) required to support two power enclosures. |
|||
| Required Power Source | 3U Power Enclosure Two redundant power feeds per power enclosure Connectors
Optimized for power cabling from bottom and network cabling from top |
|
|
|
| Availability | Power redundancy: Redundant AC feeds into power enclosures, redundant DC feeds from power enclosure to server blade enclosures, N + N redundant power supplies |
|
|
|
| Minimum Rack Requirements |
Mounts in ProLiant, and Telco racks and Third Party racks that meet the
following criteria:
|
|
|
|
| Rack Airflow Requirements |
Rack 10000 series Cabinets |
| CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: | |
|
|
| CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. | |
|
|
|
|
ProLiant Essentials Foundation Pack Software for the ProLiant BL Server Blades |
|
||||
| NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials |
|
|
Configuration Information Factory Integrated Models
|
For a complete configuration of the HP BladeSystem, please do the following: |
||
| Step
1: Select desired model, configuration and quantity of HP ProLiant server
blades NOTE: For server blade information, please visit: http://h18000.www1.hp.com/products/quickspecs/division/11070.html |
||
|
|
| Step
2: Determine quantity of HP BladeSystem p-Class Server Blade Enclosures
to purchase. NOTE: Each HP BladeSystem p-Class Server Blade Enclosure holds up to 16 HP ProLiant server blades plus two Interconnects based on server blade selection. |
| HP BladeSystem p-Class Server Blade Enclosures |
HP BladeSystem p-Class Starter Kit with 8 ProLiant Essentials Rapid Deployment
Licenses
NOTE: Power enclosures not required when ordering this equipment |
390738-B21
|
| HP BladeSystem p-Class Server
Blade Enclosure with enhanced backplane components with 8 ProLiant Essentials
Rapid Deployment Licenses NOTE: HP BladeSystem p-Class server blade enclosures with enhanced backplane components may be required depending on which HP ProLiant server blade model is selected. For additional information regarding Blade Enclosure Compatibility, please visit the following URL: http://www.hp.com/go/bladesystem/enclosure/compatibility |
281404-B22
|
|
| HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components with ProLiant Essentials Rapid Deployment Pack Trial |
243564-B22
|
|
|
HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane
components and the HP BladeSystem Management Suite |
380625-B22
|
|
|
|
||
| Step
3: Select an interconnect kit. Each interconnect kit contains a pair of interconnects except the Cisco GESM which contains a single switch per kit. One pair of interconnects is required with each blade enclosure. For additional information on Interconnect Options, please visit: http://h18000.www1.hp.com/products/quickspecs/12331_div/12331_div.html |
||
| HP
BladeSystem p-Class Interconnects |
RJ-45 Patch Panel
2 with Fibre Channel pass through NOTE: Required for Fibre Channel connectivity on HP ProLiant BLXXp when using the patch panel interconnect |
306465-B21
|
| Cisco
Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit
Base Unit only NOTE: Two CGESM interconnect kits required per server blade enclosure. |
378926-B21
|
|
| Cisco Gigabit Ethernet
Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit (populated
with two RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules
NOTE: Two CGESM interconnect kits required per server blade enclosure. |
378927-B21
|
|
| Cisco RJ-45 10/100/1000 T/TX/T SFP Module |
378928-B21
|
|
| Cisco 1000BASE SX Fiber SFP Module |
378929-B21
|
|
| ProLiant
BL p-Class C-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches
and two QuadT2 Interconnect Modules) NOTE: Only one interconnect kit required per server blade enclosure. |
283192-B22
|
|
| HP
ProLiant BL p-Class Storage Connectivity Kit NOTE: Required for BLXXp Fibre Channel signal pass through when using the CGESM or GbE2 Interconnect Switch. NOTE: Only one Storage Connectivity Kit required per each GbE2 Interconnect Kit. NOTE: Only one Storage Connectivity Kit required for (2) CGESM Interconnect Kit. |
321745-B21
|
|
|
|
||
| Step
4: Select a HP BladeSystem p-Class power enclosure and power supplies based
on configuration. Use p-Class sizing tool to help determine power configuration: http://www.hp.com/go/bladesystem/powercalculator. |
||
| NOTE: Power enclosures and supplies are not needed if using facility DC (-48V ± 10%). | ||
| HP BladeSystem p-Class 3U Power Enclosure |
Single phase 3U power enclosure with four power supplies (Single-phase 3U power enclosure holds a max of four power supplies) (NA/JPN) |
239162-001
|
| Single phase 3U power enclosure with four power supplies (Single-phase 3U power enclosure holds a max of four power supplies) (Intl) |
239162-421
|
|
| Three-phase 3U power enclosure with six power supplies (Three-phase 3U power enclosure holds a max of six power supplies) (NA/JPN) |
230769-001
|
|
| Three-phase 3U power enclosure
with six power supplies (Three-phase 3U power enclosure holds a max of six
power supplies) (Intl) NOTE: 3U Power enclosures and supplies can also be purchased separately see options list |
230769-421
|
|
|
OR
|
||
| HP BladeSystem p-Class 1U Power Enclosure |
1U power enclosure with six power supplies |
378284-B21
|
| 1U power enclosure with two power
supplies NOTE: Additional power supplies can also be purchased separately - see options list below |
380314-B21
|
|
|
|
||
| Step 5: Select power distribution | ||
| HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure) | Scalable bus bar - Supports up to 5 server blade enclosures* |
240560-B21
|
| Mini bus bar - Supports up to 3 server blade enclosures* |
240559-B21
|
|
| Power Bus Box - Supports only 1 server blade enclosure |
240562-B21
|
|
| Dual Power Input Kit for Mini Bus Bar - required for support of two power enclosures. * Maximum depends upon power input |
364565-B21
|
|
| OR | ||
| HP PDU (only required with 1U Power Enclosure) | HP Modular Distribution Unit 40 Amp (NA/JPN)** |
252663-D75
|
| HP Modular Distribution Unit 40 Amp (Intl)** |
252663-B34
|
|
| HP Modular Distribution Unit 32 Amp (Intl)** |
252663-B33
|
|
| HP Modular Distribution Unit 24 Amp (NA/JPN)** |
252663-D74
|
|
| ** The Modular Distribution Unit Kits excludes the extension bars as they are not required with the HP BladeSystem p-class 1U power enclosure | ||
| HP Monitored Power Distribution Unit | HP 17.3 kVA S348 Monitored PDU- single input, 3Ø, 48A (NA/JPN) |
AF916A
|
| HP 22 kVA S332 Monitored PDU- single input, 3-phase, 32A (INTL) |
AF917A
|
|
| HP Two C-13 PDU Extension Bars |
AF500A
|
|
| NOTE: Each extension bar has a C19 input and 7 C13 receptacles. The option is ideal for AF916A, model S348, and AF917A, model S332, which both have only C19 outlets (12). | ||
|
|
Options
| Related Options | Three phase 3U power enclosure
with no power supplies (NA/JPN) NOTE: Single-phase 3U power enclosure holds a max of four power supplies. |
231709-001 |
| Three phase 3U power enclosure
with no power supplies (Intl) NOTE: Single-phase 3U power enclosure holds a max of four power supplies. |
231709-421 | |
| Single phase 3U power enclosure
with no power supplies (NA/JPN) NOTE: Single-phase 3U power enclosure holds a max of four power supplies. |
231710-001 | |
| Single phase 3U power enclosure
with no power supplies (Intl) NOTE: Single-phase 3U power enclosure holds a max of four power supplies) |
231710-421 | |
| Single Power Supply for 3U Power enclosure |
239161-B21
|
|
| Single Power Supply for 1U Power Enclosure | 380312-B21 | |
| Facility DC Power Connection | 240563-B21 | |
| HP BladeSystem Power Extension
Kit NOTE: This kit is specifically for HP BladeSystem p-Class customers who want to upgrade their standard server blade enclosures to enhanced server blade enclosures and would like to install an additional, redundant 3U power enclosure above the server blade enclosures rather than below them. The option kit consists of two extension cable assemblies - one for each side (A and B). |
381686-B21 | |
| HP BladeSystem p-Class Server
Enclosure Shipping Bracket Option Kit NOTE: Used to secure one server blade enclosure in a rack when moving. |
293121-B21 | |
| HP BladeSystem p-Class Power Enclosure
Shipping Bracket Option Kit NOTE: Used to secure one power enclosure in a rack when moving |
365044-B21 | |
| HP BladeSystem p-Class Server
Blade Enclosure Upgrade Kit (option) NOTE: Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support BL p-class blades and provide a single, physical iLO port for the enclosure. |
354100-B21 | |
|
|
||
|
Red Hat Enterprise Linux 4 and management bundle |
|
|
Red Hat Enterprise Linux 4 and management bundle |
|
||||
|
|
|||||
| HP
Rack 5000 Series (Metallic Carbonite) | HP 5642 Rack - Unassembled NOTE: Please see the HP Rack 5642 QuickSpecs for additional part numbers and Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12074_div/12074_div.html (Worldwide) NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower |
358254-B21 |
|
| ||
| HP Rack 10000 G2 Series (Graphite Metallic) | 10642 G2 (42U) Rack Cabinet - Pallet |
AF001A
|
| 10642 G2 (42U) Rack Cabinet - Shock Pallet |
AF002A
|
|
| 10642 G2 (42U) Rack Cabinet - Crated |
AF003A
|
|
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet |
AF004A
|
|
| 10642 G2 (42U) Rack Shock Pallet- for field racking (NA only) |
AF007A
|
|
| 10636 G2 (36U) Rack Cabinet - Shock Pallet |
AF011A
|
|
| 10636 G2 (36U) Rack Cabinet - Crated |
AF012A
|
|
| 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet |
AF013A
|
|
| 10636 G2 (36U) Rack Cabinet, without door - Shock Pallet |
AF014A
|
|
| 10642 G2 (42U) Side Panels (set
of two) (Graphite Metallic) |
AF054A
|
|
| 10636 G2 (36U) Side Panels (set
of two) (Graphite Metallic) |
AF056A
|
|
| 10636 G2 Rear Extension Kit |
AF060A
|
|
| 600mm G2 Stabilizer Option Kit (Graphite) |
AF062A
|
|
| NOTE: Please see
the Rack 10000 G2 QuickSpecs for additional part numbers and Technical Specifications
such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html (Worldwide) NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. |
||
|
|
||
|
HP Rack 10000 Series |
HP S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22
|
|
HP Rack 10622 (22U) Cabinet - Pallet |
245163-B21 |
|
| NOTE: xxxxxx-B21
(pallet) used to ship empty racks shipped on a truck. xxxxxx-B22 (shock
pallet) used to ship racks with equipment installed (by custom systems,
VARs and Channels). NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. |
||
| NOTE: Please
see the Rack 10000 QuickSpecs for additional part number and Technical Specifications
such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.html (Worldwide) NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower |
||
|
|
||
|
Monitors and Keyboards |
TFT7210R Rack Mounted 17" Monitor |
348373-B21
|
| NOTE: For a complete
list of Monitors please view the following URL: http://www.hp.com/go/kvm. |
||
| TFT7600 Rackmount Keyboard Monitor US |
AG052A
|
|
| TFT7600 Rackmount Keyboard Monitor UK |
AG053A
|
|
| TFT7600 Rackmount Keyboard Monitor FR |
AG055A
|
|
| TFT7600 Rackmount Keyboard Monitor SP |
AG057A
|
|
| TFT7600 Rackmount Keyboard Monitor DEN |
AG058A
|
|
| TFT7600 Rackmount Keyboard Monitor NOR |
AG059A
|
|
| TFT7600 Rackmount Keyboard Monitor SWI |
AG061A
|
|
| TFT7600 Rackmount Keyboard Monitor BEL |
AG063A
|
|
| TFT7600 Rackmount Keyboard Monitor RUS |
AG065A
|
|
| TFT7600 Rackmount Keyboard Monitor INTL |
AG066A
|
|
| 1U Rackmount Keyboard with USB, US |
AG072A
|
|
| 1U Rackmount Keyboard with USB, UK |
AG073A
|
|
| 1U Rackmount Keyboard with USB, GR |
AG074A
|
|
| 1U Rackmount Keyboard with USB, FR |
AG075A
|
|
| 1U Rackmount Keyboard with USB, ITL |
AG076A
|
|
| 1U Rackmount Keyboard with USB, SP |
AG077A
|
|
| 1U Rackmount Keyboard with USB, DEN |
AG078A
|
|
| 1U Rackmount Keyboard with USB, NOR |
AG079A
|
|
| 1U Rackmount Keyboard with USB, SE/FI |
AG080A
|
|
| 1U Rackmount Keyboard with USB, SWI |
AG081A
|
|
| 1U Rackmount Keyboard with USB, PORT |
AG082A
|
|
| 1U Rackmount Keyboard with USB, BEL |
AG083A
|
|
| 1U Rackmount Keyboard with USB, JPN2 |
AG084A
|
|
| 1U Rackmount Keyboard with USB, RUS |
AG085A
|
|
| 1U Rackmount Keyboard with USB, INTL |
AG086A
|
|
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower | ||
|
|
||
| HP KVM Switch Options | 2x1x16 IP Console Switch with Virtual Media |
AF601A
|
| 4x1x16 IP Console Switch with Virtual Media |
AF602A
|
|
| 2x16 Server Console Switch with Virtual Media |
AF600A
|
|
| USB Virtual Media Interface Adapter |
AF603A
|
|
| PS/2 Virtual Media Interface Adapter,
1 pack NOTE: Requires PS/2 and one USB port on server. |
AF604A
|
|
| HP 0x1x8 Server Console Switch |
336044-B21
|
|
| HP 0x2x16 Server Console Switch |
336045-B21
|
|
| PS/2 Interface Adapter, 1-pack |
262588-B21
|
|
| PS/2 Interface Adapter, 8-pack |
262587-B21
|
|
| USB Interface Adapter, 1-pack |
336047-B21
|
|
| Serial Interface Adapter, 1-pack with power supply |
373045-B21
|
|
| NOTE: Cat5e cables are required to connect Interface Adapters to Consoles Switches. Cat52 cables can be found at the following URL: http://www.hp.com/go/kvm | ||
| NOTE For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm | ||
|
|
||
|
HP Serial Console Server Options | HP 16 Port Serial Console Server (worldwide) | AF101A |
| HP 48 Port Serial Console Server (worldwide) | AF102A | |
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack | AF103A | |
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack | AF110A | |
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
| | ||
| Service and Support Offerings (HP Care Pack Services) |
| ||||||||||||||||||||
|
|
|
Technical Specifications
| HP BladeSystem p-Class Server Blade Enclosure |
Dimensions |
Height |
10.5 in (26.67 cm) |
|
| Width |
17.60 in (44.70 cm) |
|||
| Depth |
28.86 in (73.30 cm) |
|||
|
Input Specifications |
Rated input voltage |
-43 VDC to -53 VDC |
Nominal -48 VDC | |
| Rated input current | 62.5 A at -48 VDC | |||
|
Rated input Power |
3000 W |
|||
|
Individual Server Blade |
Rated input voltage | -43 VDC to -53 VDC | Nominal -48 VDC | |
| Rated input current | 6.25 A at -48 VDC | |||
| Rated input Power | 300 W | |||
|
Temperature Range |
Operating | 50° to 95° F (10° to 35° C) | ||
| Non-Operating | -22° to 140° F (-30° to 60° C) | |||
|
Relative Humidity |
Operating | 20% to 80% | ||
| Non-Operating | 5% to 95% | |||
|
Wet Bulb Temperature |
Operating | 82.4° F (28° C) | ||
| Non-Operating | 101.7° F (38.7° C) | |||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | ||||
|
|
||||
| HP BladeSystem p-Class Server Blade Enclosure (with enhanced backplane components) |
Dimensions |
Height |
10.5 in (26.67 cm) |
|
| Width |
17.60 in (44.70 cm) |
|||
| Depth |
28.86 in (73.30 cm) |
|||
|
Input Specifications |
Rated input voltage |
-43 VDC to -53 VDC |
Nominal -48 VDC | |
| Rated input current | 125 A at -48 VDC | |||
|
Rated input Power |
6000 W |
|||
|
Individual Server Blade |
Rated input voltage | -43 VDC to -53 VDC | Nominal -48 VDC | |
| Rated input current | 14.6 A at -48 VDC | |||
| Rated input Power | 700 W | |||
|
Temperature Range |
Operating | 50° to 95° F (10° to 35° C) | ||
| Non-Operating | -22° to 140° F (-30° to 60° C) | |||
|
Relative Humidity |
Operating | 20% to 80% | ||
| Non-Operating | 5% to 95% | |||
|
Wet Bulb Temperature |
Operating | 82.4° F (28° C) | ||
| Non-Operating | 101.7° F (38.7° C) | |||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | ||||
|
|
||||
| 1U Power Enclosure | Enclosure Dimensions | Height |
4.47 (1.75 in)
|
| Width |
44.7 cm (17.60 in)
|
||
| Depth |
68.96cm (27.15 in)
|
||
|
Shipping Dimensions |
Height |
30.17cm (11.88 in)
|
|
| Width |
60cm (23.63 in)
|
||
| Depth |
91.44cm (36.00 in)
|
||
|
Weight |
No Power Supplies |
10Kg (22lb)
|
|
| Shipping Weights | 2 Power Supplies | 25Kg (54 lb) | |
| 6 Power Supplies | 34Kg (75 lb) | ||
|
Input Requirements |
Rated input voltage |
200 VAC to 240 VAC
|
|
| Rated input frequency |
50 Hz to 60 Hz
|
||
| Rated input current per power supply |
11.1A at 208 VAC
10.5A at 220 VAC 13A Max at 180 VAC |
||
| Rated input power per power supply |
2310 Watts Max
|
||
| Power connector |
IEC-320 C20
|
||
| Power Cords | 2 Power Supplies | 2 x IEC-320 C19-C20 1.22m (4ft) | |
| 6 Power Supplies | 6 x IEC-320 C19-C20 1.22m (4ft) | ||
|
Output |
1 Power
Supply |
2 Power
Supplies |
3 Power
Supplies |
||
| Rated output current |
39 Amps
|
78 Amps
|
117 Amps
|
||
| Rated output power |
2000W
|
4000 Watts
|
6000 Watts
|
||
| Rated output voltage |
-48.8 VDC to -54 VDC
|
||||
| Nominal power |
6000 Watts at 208 VAC
|
||||
| Ambient Temperature Range (See NOTE) |
Operating |
10° to 35° C (50° to 95° F)
|
|||
| Shipping |
-30° to 60° C (-22° to 140° F)
|
||||
| Relative humidity, non-condensing (See NOTE) |
Operating |
20% to 80 %
|
|||
| Non-operating |
5% to 95%
|
||||
| Wet Bulb Temperature |
Operating |
28° C (82.4° F)
|
|||
| Non-operating |
38.7° C (101.7° F)
|
||||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||||
|
|
|||||
| 3U Power Enclosures (North America / Japan) |
Single-Phase Model | Three-Phase Model | ||
| Dimensions | Height | 5.25 in (13.34 cm) | 5.25 in (13.34 cm) | |
| Width | 27.15 in (68.96 cm) | 27.15 in (68.96 cm) | ||
| Depth | 17.60 in (44.7 cm) | 17.60 in (44.7 cm) | ||
| Weights | No Hot-Plug Power Supplies |
47.5 lb (21.55 kg) | 47.5 lb (21.55 kg) | |
| All Hot-Plug Power Supplies |
99.5 lb (45.13 kg) | 125.5 lb (56.93 kg) | ||
| Input Requirements | Rated input voltage | 200 VAC to 240 VAC | 200 VAC to 240 VAC line to line | |
| Rated input frequency | 50 Hz to 60 Hz | 50 Hz to 60 Hz | ||
| Rated input current per side |
24A | 24A per phase | ||
| Rated input power per side |
4992 W | 8,640W | ||
| Power cord | 1 NEMA L6-30P per side | 1 NEMA L15-30P per side | ||
| Output Voltage Specifications |
Rated output voltage | -48.8 VDC to -54 VDC | -48.8 VDC to -54 VDC | |
| Rated output current | 99A | 170A | ||
| Rated output power | 4298 W | 8310 W | ||
| Nominal power | 4158 W at 208 VAC | 7202 W at 208 VAC | ||
| Ambient Temperature Range (See NOTE) |
Operating | 50° to 95° F (10° to 35° C) |
50° to 95° F (10° to 35° C) |
|
| Shipping | -22° to 140° F (-30° to 60° C) |
-22° to 140° F (-30° to 60° C) |
||
| Relative humidity, non-condensing (See NOTE) |
Operating | 20% to 80% | 20% to 80% | |
| Non-operating | 5% to 95% | 5% to 95% | ||
| Wet Bulb Temperature |
Operating | 82.4° F (28° C) | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | ||||
|
|
||||
| 3U Power Enclosures (International) |
Single-Phase Model | Three-Phase Model | ||
| Dimensions | Height | 5.25 in (13.34 cm) | 5.25 in (13.34 cm) | |
| Width | 27.15 in (68.96 cm) | 27.15 in (68.96 cm) | ||
| Depth | 17.60 in (44.7 cm) | 17.60 in (44.7 cm) | ||
| Weights | No Hot-Plug Power Supplies |
47.5 lb (21.55 kg) | 47.5 lb (21.55 kg) | |
| All Hot-Plug Power Supplies |
99.5 lb (45.13 kg) | 125.5 lb (56.93 kg) | ||
| Input Requirements | Rated input voltage | 200 VAC to 240 VAC | 346VAC - 415VAC line to line 200 VAC to 240 VAC line to neutral |
|
| Rated input frequency | 50 Hz to 60 Hz | 50 Hz to 60 Hz | ||
| Rated input current per side |
24A | 20A per phase | ||
| Rated input power per side |
5760 W | 10,552 W | ||
| Power cord | 1 IEC 309 3-pin, 32A per side |
1 IEC 309 5-pin, 32A per side |
||
| Output Voltage Specifications |
Rated output voltage | -48.8 VDC to -54 VDC | -48.8 VDC to -54 VDC | |
| Rated output current | 99A | 180A | ||
| Rated output power | 4798 W | 8790 W | ||
| Nominal power | 4598 W at 230 VAC | 8790 W at 230 VAC | ||
| Ambient Temperature Range (See NOTE) |
Operating | 50° to 95° F (10° to 35° C) |
50° to 95° F (10° to 35° C) |
|
| Shipping | -22° to 140° F (-30° to 60° C) |
-22° to 140° F (-30° to 60° C) |
||
| Relative humidity, non-condensing (See NOTE) |
Operating | 20% to 80% | 20% to 80% | |
| Non-operating | 5% to 95% | 5% to 95% | ||
| Wet Bulb Temperature |
Operating | 82.4° F (28° C) | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | ||||
|
|
||||
| Power Distribution Devices | Power Bus Box | Mini Bus Bar | Scalable Bus Bar | |
| Power
Enclosures or facility DC feeds Supported (3U each) | 1 | 1 | 2 | |
| Server blade enclosures supported (6U each) | 1 | 3 | 5 | |
| Total rack height of supported enclosures | 9U | 21U | 36U | |
| Dimensions | ||||
| Height | 5.1 in (12.95 cm) | 19.45 in (49.40 cm) | 48.57 in (123.37 cm) | |
| Width | 3.6 in (9.14 cm) each | 19.74 in (50.14 cm) | 19.74 in (50.14 cm) | |
| Depth | 3.25 in (8.26 cm) | 2.2 in (5.59 cm) | 2.2 in (5.59 cm) | |
| Weight | 3.62 lb (1.64 kg) | 13.2 lb (5.9 kg) | 26 lb (11.79 kg) | |
| Rated Operating Voltage | -43.2 VDC to -54 VDC | -43.2 VDC to -54 VDC | -43.2 VDC to -54 VDC | |
| Max Total Power Supported | 3000 W | 9000 W | 15000 W | |
| Total
Max Input Current At Minimum Voltage | 69.44 A at -43.2VDC | 208.32 A at -43.2 VDC | 347.2 A at -43.2 VDC (equivalent of 175A per feed) | |
| Total
Max Input Current At Nominal Voltage | 62.5 A at -48VDC | 187.5 A at -48 VDC | 312.5
A at -48 VDC (equivalent of 175A per feed) | |
| Max
Current Per Power Feed | 70A | 70A | 210A | |
| Max Local Ambient Temperature | 149° F (65° C) | 149° F (65° C) | 149° F (65° C) | |
| NOTE: All systems support redundant A & B feeds. Scalable bus bar supports dual A and dual B feeds. | ||||
|
| ||||
| Facility DC Power Connection |
Voltage |
Nominal input voltage |
-48 VDC |
| Operating voltage range |
-48VDC ± 10% or -43.2 VDC to -52.8 VDC |
||
| Max Input voltage slew rate | 0.5V/uS | ||
| Redundant feed voltages* (A & B) |
*A and B feeds must differ by no more than 5VDC during steady state operation | ||
| Ripple/Noise | 480 mV PARD** | ||
| Overshoot | Must remain within regulation limits on all feeds during startup or shutdown | ||
| Voltage transients |
Must not exceed -60 VDC |
||
|
Current |
Max steady state input current | 62.5A per server blade enclosure installed at -48VDC | |
| Max steady state current per feed/total | |||
|
70 A/70A | ||
|
210 A/210A | ||
|
210 A/350A or equivalent of 175A per feed* | ||
| In-rush current | Must support up to 2X the maximum operating current per server blade enclosure (125 A) for up to 1.0 mS | ||
| Input over-current | Customer provided fusing for facility DC feeds that protects the system from catastrophic over-current within 20 uS. Fuse should sustain all in-rush and operating currents. | ||
| Max Input Current Slew Rate | 1A/uS | ||
| Max Rated Power | 3000W per server blade enclosure | ||
|
Connections and Cables |
HP provided facility DC cable connection kit: | ||
|
|||
| The power cable assemblies consist of 1/0AWG, color-coded, flexible cable rated at 105° C, terminated with bus mating connectors at one end and unterminated at the other end. The cable length provided enables the customer to route to a fuse panel within or adjacent to the rack. | |||
| *NOTE: All systems support redundant A and B feeds. Scalable bus bars support dual A and dual B feeds. | |||
| **NOTE: Periodic and random noise (PARD). Maximum allowable peak-to-peak ripple and noise (as measured at the load on any output channel). The ripple and noise is measured over a 20 Hz to 100 MHz frequency band. A resistive load (non-electronic) is used for this measurement. Each output is by-passed to return by a 10uF tantalum capacitor with an ESR less than 100 milli-Ohms in parallel with a 0.47 uF ceramic capacitor, at the point of load. The load cable is 12 feet of twisted wire capable of carrying the current. The printed wiring board assembly is installed in its enclosure for this measurement, or the measurement leads are properly shielded with Earth grounds applied to the insert. | |||
|
|
|||
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
|
|
|
|||
|
© Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |