Overview
|
HP BladeSystem p-Class Interconnect Components |
|
|
| At A Glance |
|
This document covers the HP BladeSystem p-Class Interconnects Components only. For more information on HP ProLiant Server Blades and HP BladeSystem p-Class Infrastructure please see the following QuickSpecs: HP ProLiant Server Blade QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/11070.html HP BladeSystem solutions starts with a Server Blade Enclosure, HP ProLiant
Server Blades, networking interconnects, SAN switches, management tools
and a centralized power sub-system.
NOTE: For additional information
on HP BladeSystem SAN switches, please see the following URL: http://h18004.www1.hp.com/products/blades/components/san-switches.html
|
| |
|
|
|
Standard Features (HP BladeSystem p-Class Interconnect Components)
| HP ProLiant BL p-Class Interconnect Components | |
| ProLiant
BL p-Class Interconnect Switch Option (Every HP BladeSystem p-Class server blade enclosure requires two interconnect switches OR two RJ-45 patch panels) |
Provides up to a 32 to 1 server networking cable reduction per server enclosure depending on the mix of HP ProLiant BL20p, HP ProLiant BL25p, HP ProLiant BL30p, HP ProLiant BL35p, HP ProLiant BL40p and HP ProLiant BL45p server blades. Each interconnect switch (two per enclosure) reduces up to sixteen internal server network (NIC) ports to six external ports (four on a modular rear mounting interconnect module and two on the switch front panel). This provides a total of twelve external ports per server blade enclosure. Only one to all twelve external ports may be used per server blade enclosure. |
|
The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kits are
for applications that require network adapter consolidation to 1000 Mbps
(Gigabit Ethernet) in a Cisco infrastructure. The CGESM supports the same
Fibre Channel pass-through as the GbE2.
|
|
|
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) are for applications that
require network adapter consolidation to 1000 Mbps (Gigabit Ethernet)
and HP ProLiant Server Blade Fibre Channel pass-through.
The optional ProLiant BL p-Class Storage Connectivity Kit (321745 -B21) is required for Fibre Channel pass-through when using either the C-GbE2 or F-GbE2 Interconnect Kit. |
|
|
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that
require network adapter consolidation to 100 Mbps (Fast Ethernet).
|
|
| Also included (per Interconnect Switch): | |
|
|
|
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).
|
|
| ProLiant BL Interconnect Switch Management System and Utilities: | |
| Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing of speed and duplex mode, and more. | |
|
|
|
| ProLiant
BL p-Class Storage Connectivity Kit Option (Supports two CGESM or GbE2 switches per kit) |
The Storage Connectivity Kit
is used if Fibre Channel signal pass-through is desired when using the CGESM
or GbE2 Interconnect Switch. Therefore, both LAN cable consolidation and
SAN connectivity is possible using a single interconnect option. Order one
Storage Connectivity Kit per server blade enclosure for Fibre Channel pass
through. The Storage Connectivity Kit includes two OctalFC Interconnect Modules that provide sixteen open transceiver slots for the pluggable small form factor transceivers that come with each Dual port Fibre Channel Adapter. The Storage Connectivity Kit supports up to sixteen Fibre Channel signals). |
|
|
|
| HP ProLiant BL p-Class SAN
Switches |
Embedded Fibre Channel SAN switching
within the p-Class Server Enclosure. Brocade and McDATA based SAN switches
featuring 4Gb ASIC technology providing fabric connectivity for all HP ProLiant
BL p-Class Server blades.
The Brocade 4Gb SAN Switch for HP p-Class BladeSystem is a 4Gb
12 port Fibre Channel SAN switch. Three factory configurations:
For additional information on the Brocade 4Gb SAN Switch for HP p-Class BladeSystem please see the following URL: http://h18006.www1.hp.com/products/storageworks/b4gbsanswitchblade/index.html The McDATA 4Gb SAN Switch for HP p-Class BladeSystem is a 4Gb
10 port Fibre Channel SAN Switch. This product comes in one factory configuration.
There is an enhanced software license available for the McDATA SAN switch.
For additional information on the McDATA 4Gb SAN Switch for HP p-Class BladeSystem please see the following URL: http://h18006.www1.hp.com/products/storageworks/mcd4gbsanswitch/index.html NOTE: Both Brocade and McDATA SAN switches are shipped in singles (one switch per kit), for redundant configurations please order two switch kits. |
|
|
|
| HP
ProLiant BL p-Class RJ-45 Patch Panel (Two patch panels per kit) (Every BL p-Class server blade enclosure requires two Interconnect switches OR two RJ-45 patch panels) |
6U (10.5-inch), Plugs into HP BladeSystem p-Class 6U server blade enclosures |
| Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections | |
| Supports Gigabit Ethernet network adapters | |
| 16 RJ-45 connectors on the back of each BL p-Class 6U RJ-45 Patch Panel (32 RJ-45 connections per server blade enclosure) | |
|
|
|
| HP ProLiant BL
p-Class RJ-45 Patch Panel 2 (with Fibre Channel pass through) (Two patch panels per kit) (Every BL p-Class server blade enclosure requires two Interconnect switches OR two RJ-45 patch panels) NOTE: The Patch Panel 2 or a Switch Interconnect Kit is required for SAN connectivity on HP |
6U (10.5-inch), Plugs into HP BladeSystem p-Class 6U server blade enclosures | |
| Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections also used to pass Fibre Channel signals for SAN connectivity | ||
| Supports Gigabit Ethernet network adapters | ||
| 16 RJ-45 connectors on the back of each RJ-45 patch panel 2 (32 RJ-45 connections per server blade enclosure) | ||
| Fibre
Channel, pass through |
Fibre Channel signals travel from a HP ProLiant BL25p server blade with a Dual-Port Fibre Channel Adapter through p-Class server blade enclosure backplane. The Fibre Channel signals are terminated through the RJ-45 Patch Panel 2 in the interconnect bays. To provide redundancy each server blade has two Fibre Channel signals and one Fibre Channel signal terminates through the right RJ-45 Patch Panel 2, one Fibre Channel signal travels terminates through the left RJ-45 Patch Panel 2. | |
| 8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the front of each RJ-45 patch panel 2 (16 Fibre Channel connections per server blade enclosure); for insertion of SPF transceivers included with the BL20p G3 Dual-port Fibre Channel Adapter. | ||
| | ||
| Required
Network Cabling | 10Base-T
| Categories 3, 4 or
5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) |
| 100Base-TX | Category
5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) | |
| 1000Base-T | Category
5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) | |
| 1000Base-SX | 50/125
µm Multimode Fiber, 400 MHz/Km (500 meters) 50/125 µm Multimode Fiber, 500 MHz/Km (550 meters) 62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters) 62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters) | |
| NOTE:
For cabling information, refer to the Web site at: | ||
|
|
Standard Features
| Intelligent Manageability |
Interconnect Switch Management System and Utilities (Interconnect Switch option) |
|
|
|
| Availability |
Interconnect Switch Availability
|
|
|
|
| Security | Interconnect switch multilevel
user names and passwords, management interface time out period setting,
SSH*, SCP secure copy protocol, port-based
IEEE 802.1Q tagged VLANs, RADIUS user authentication and authorization*,
and IP address restriction *NOTE: CGESM and GbE2 Interconnect Switch only |
|
|
|
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration
and deployment services for HP servers and storage products. Customers
can choose how their factory solutions are built, tested, integrated,
shipped and deployed. Factory Express offers service packages for simple configuration, racking,
installation, complex configuration and design services as well as individual
factory services, such as image loading, asset tagging and custom packaging.
HP products supported through Factory Express include: a wide array of
servers and storage: HP Integrity, HP ProLiant & HP ProLiant Server
Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx,
EVA3000 & EVA5000, XP, rackable tape libraries and configurable network
switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
|
|
|
| Service and Support |
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. NOTE: Server Blade Limited Warranty
includes 3 year Parts, 3 year Labor, 3-year on-site support. This warranty
supports the HP ProLiant BL20p, HP ProLiant 25p, HP ProLiant 40 and HP
ProLiant 45p Server Blades. HP Care Pack services provide total care and support expertise with committed response designed to meet your IT and business needs. HP Care Pack services for HP BladeSystem p-Class server blade enclosure covers the enclosure including patch panels, HP supported Ethernet interconnects, power enclosure with power supplies and power distribution. To fully capitalize on your HP BladeSystem servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a HP BladeSystem server support offer to help you speedily deploy and maximize system uptime. Recommended Service - Simplify ProLiant solution implementation,
maintenance and management.
Enhanced Service - Optimize service level to increase IT performance
and availability
Installation & Start-Up service for HP BladeSystem Infrastructure plus HP BladeSystem Enhanced Network Installation and Start-UP as per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excluding HP holidays. For a complete listing of service offerings
and information visit: |
|
|
Options
| Configuration Steps |
| For a complete configuration on the HP ProLiant Server Blades, please do the following: |
| Step 1: Select desired model,
configuration and quantity of HP ProLiant server blades NOTE: For server blade information, please visit: http://h18000.www1.hp.com/products/quickspecs/north_america/11070.html |
|
|
| Step 2: Determine quantity
of HP BladeSystem p-Class Server Blade Enclosures to purchase NOTE: Each HP BladeSystem p-Class Server Blade Enclosure holds 2,4,8 or 16 HP ProLiant server blades plus two Interconnects depending on server blade selection. NOTE: For additional information on HP BladeSystem p-Class Infrastructure please visit: http://h18000.www1.hp.com/products/quickspecs/12330_na/12330_na.html |
|
|
| Step 3: Select an interconnect
kit. Each interconnect kit contains a pair of interconnects except the Cisco
GESM which contains a single switch per kit. One pair of interconnects is
required with each blade enclosure. NOTE: For additional information on Interconnect Options, please visit: http://h18000.www1.hp.com/products/quickspecs/12164_na/12164_na.html |
|
|
| HP
BladeSystem p-Class Interconnects |
RJ-45 Patch Panel
2 with Fibre Channel pass through NOTE: Required for Fibre Channel connectivity on HP ProLiant BLXXp when using the patch panel interconnect |
306465-B21 |
| Brocade 4Gb SAN Switch for HP p-Class BladeSystem |
A7533A
|
|
| Brocade 4Gb SAN Switch Full Fabric Switch |
A7534A
|
|
| Brocade 4Gb SAN Switch
w/Power Pack NOTE: Two SAN switch kits required per server blade enclosure |
A7535A
|
|
| McDATA 4Gb SAN Switch
for HP p-Class BladeSystem NOTE: Two SAN switch kits required per server blade enclosure. |
A8001A
|
|
| Cisco Gigabit Ethernet
Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit only NOTE: Two CGESM interconnect kits required per server blade enclosure. |
378926-B21
|
|
| Cisco Gigabit Ethernet
Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit (populated
with two RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules NOTE: Two CGESM interconnect kits required per server blade enclosure. |
378927-B21
|
|
| Cisco RJ-45 10/100/1000 T/TX/T SFP Module |
378928-B21
|
|
| 1000BASE SX Fiber SFP Module |
378929-B21
|
|
| ProLiant BL p-Class
C-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two
QuadT2 Interconnect Modules) NOTE: Only one interconnect kit required per server blade enclosure. |
283192-B22
|
|
| HP ProLiant BL p-Class
Storage Connectivity Kit NOTE: Required for BLXXp Fibre Channel signal pass through when using the CGESM or GbE2 Interconnect Switch. NOTE: Only one Storage Connectivity Kit required per each GbE2 Interconnect Kit. NOTE: Only one Storage Connectivity Kit required for (2) CGESM Interconnect Kit. |
321745-B21
|
|
|
|
||
| Step 4: Select a HP BladeSystem
p-Class power enclosure and power supplies based on configuration NOTE: For additional information on HP BladeSystem p-Class Infrastructure please visit: http://h18000.www1.hp.com/products/quickspecs/12330_na/12330_na.html |
| Use p-Class sizing tool to help determine
power configuration: http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls NOTE: Power enclosures and supplies are not needed if using facility DC (-48V ± 10%). |
|
|
| Step 5: Select
power distribution (only required with 3U power enclosures) NOTE: For additional information on HP BladeSystem p-Class Infrastructure please visit: http://h18000.www1.hp.com/products/quickspecs/12330_na/12330_na.html |
|
|
| Service and Support Offerings (HP Care Pack Services) |
| ||||||||||||||||||||
|
|
|
Technical Specifications
| Operating and Performance Specifications for RJ-45 Patch Panel 2 with Fiber Channel pass through |
Dimensions | Height |
10.405 in (26.43 cm) |
| Width |
1.535 in (3.899 cm) | ||
| Depth | 27.697 in (70.35 cm) | ||
| Capability | IEEE 802.2, 802.3, 802.3u | ||
|
Network Transfer Rate |
10 Base-T (half-duplex) |
10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (full-duplex) | 1000 Mbps | ||
| Fiber Channel SAN | Velio VC1070 re-timer | Auto-rate negotiate between 2G and 1G | |
|
Connector | Network | RJ-45 in the back. | |
| Fiber Channel SAN | Pluggable SFP optical slot in the front. | ||
|
Cable Support | 10 Base-TX | Categories
3, 4, or 5 UTP (2 or 4 pair); up to 328 ft (100 m) | |
| 100 Base-TX | Category 5 UTP (2 pair); up to 328 ft/100 m | ||
| 1000 Base-TX | Category 5E (4 pair); up to 328 ft (100 m) | ||
| Fiber Channel | SFP optical cable | ||
| EMI | FCC Class A | ||
| ICES-003 Class A | |||
| AS/NZS 3548 Class A | |||
| VCCI Class A | |||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
| | |||
| Operating and Performance Specifications for RJ-45 Patch Panel |
Dimensions | Height |
10.405 in (26.43 cm) |
| Width |
1.535 in (3.899 cm) | ||
| Depth | 27.697 in (70.35 cm) | ||
| Capability | IEEE 802.2, 802.3, 802.3u | ||
|
Network Transfer Rate |
10 Base-T (half-duplex) |
10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (full-duplex) | 1000 Mbps | ||
| Connector |
Network | RJ-45 in the back | |
| Cable Support | 10 Base-TX | Categories 3, 4, or 5 UTP
(2 or 4 pair); up to 328 ft (100 m) | |
| 100 Base-TX | Category 5 UTP (2 pair); up to 328 ft (100 m) | ||
| 1000 Base-TX | Category 5E (4 pair); up to 328 ft (100 m) | ||
|
Power Requirements | 200 mA at + 5V DC; 500 mA at -48V | ||
| Temperature Range | Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative
Humidity (non-condensing) | Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature | Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
| | |||
| Operating and Performance Specifications for ProLiant BL p-Class GbE Interconnect Switch |
Dimensions |
Height |
10.405 in (26.43 cm) |
| Width |
1.535 in (3.899 cm) |
||
| Depth |
27.697 in (70.35 cm) |
||
| Weight | 11.5 lb/5.2 kg per interconnect switch | ||
| Performance | 9.6 Gbps external port bandwidth per server blade enclosure (full duplex) | ||
| Forwarding rate 0.15 million pps per 10/100 port, 1.5 million pps per gigabit port, (64-byte packets) | |||
| Non-blocking, full-wire speed for all connections | |||
| Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support | |||
| Forwarding Mode | Store and forward | ||
| MAC Addresses | 8,191 per interconnect switch; MAC address based filtering and MAC address packet priority configuring | ||
| Forwarding Table Age Time |
Maximum age: 1 to 1,000,000 seconds; default: 300 seconds | ||
| Memory | 32MB Main, 6MB flash and 16MB packet buffer per interconnect switch | ||
| Compliance | IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE only), 802.1D, 802.1p, 802.3ac, 802.3ad (Static), and 802.1Q | ||
| SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9 | |||
| MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB (RFC 2674), Entity MIB (RFC 2037), SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757), and HP Enterprise Switch MIBs and Environmental Traps | |||
| IGMP v1 (RFC 1112), IGMP v2 (RFC 2236), SNTP (RFC 1361), Telnet (RFC 854), TFTP client (RFC 783), BootP client, (RFC 2132), DHCP client, (RFC 2131) and ZModem, | |||
|
Network Transfer Rate |
10 Base-T (half-duplex) |
10 Mbps |
|
|
10 Base-T (full-duplex) |
20 Mbps |
||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (half and full-duplex) | 2000 Mbps | ||
|
1000 Base-SX (full-duplex) |
2000 Mbps |
||
|
Connector |
12 RJ-45, 2 DB-9 (C-GbE Interconnect
Kit) 4 LC fiber, 8 RJ-45, 2 DB-9 (F-GbE Interconnect Kit) |
||
|
Cable Support |
FCC Class A | ||
| ICES-003 Class A | |||
| AS/NZS 3548 Class A | |||
| VCCI Class A | |||
| Safety | UL/CUL Listed Accessory | ||
| CE | |||
|
Power Requirements |
-48VDC: 1050 mA, 50 W maximum (per interconnect switch) | ||
| Temperature Range | Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative Humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature | Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
|
|
|||
| Operating specifications for McDATA 4Gb SAN Switch |
Fibre Channel ports |
2 external ports (ships with two 4Gb SFPs) | |
|
Performance |
4 GB/sec line speed, full duplex | ||
|
Certified maximum |
24 switches, 7 hops; larger fabrics certified as required | ||
|
Switch core |
Non-blocking | ||
|
Fabric latency |
<2 µ sec. with no contention, cut-through routing | ||
|
Maximum frame size |
2112-byte payload | ||
|
Classes of service |
Class 2, Class 3, Class F (inter-switch frames) | ||
|
Port types |
FL_Port, F_Port, and E_Port; self-discovery based on G_Port or GL_Port | ||
|
Data traffic types |
Fabric switches support unicast, multicast (256 groups), and broadcast | ||
|
Media types |
Small Form-Factor Pluggable (SFP) | ||
|
Laser |
Short-wave up to 500 m (1,640 ft); long-wave up to 10 km (6.2 mi) when available | ||
|
Options |
SFP media-take out | ||
|
Supported software |
SANtegrity Enhanced Software | ||
|
Management access |
10/100 Ethernet (RJ-45) | ||
|
Diagnostics |
POST and embedded online/offline diagnostics | ||
| Dimensions | Height |
3.4 in (8.6 cm) | |
| Width |
1.5 in (3.8 cm) | ||
| Depth |
4.75 in (12.1 cm) 7 in (17.9 cm) with handle | ||
| Weight | 1.94 lbs (.88 kg) | ||
|
Temperature |
Operating | 32° to 104° F (0° to 40° C) | |
|
|
|||
| Operating and Performance Specifications for GbE2 Interconnect Switch |
Dimensions |
Height |
10.405 in (26.43 cm) |
| Width |
1.535 in (3.899 cm) |
||
| Depth |
27.697 in (70.35 cm) |
||
| Weight | 12.0 lb/5.4 kg per interconnect switch | ||
|
Performance |
24 Gbps External port bandwidth per server blade enclosure (full duplex) | ||
| Forwarding rate 1.5 million pps per gigabit port (64-byte packets) | |||
| Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support | |||
|
Forwarding Mode |
Store and forward | ||
| MAC Addresses | 2,048 per interconnect switch | ||
| Forwarding Table Age Time |
Maximum age: 1 to 65535 seconds; default: 300 seconds | ||
| Memory | 128MB Main, 32MB flash and 2MB packet buffer per interconnect switch | ||
| Compliance | IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE2 only), 802.1D, 802.3ac, 802.3ad (Static), and 802.1Q | ||
| SNMP v1 (RFC 1157), MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB , Entity MIB (RFC 2037), RADIUS Authentication MIB, 802.3-2002 MIB, SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757) and HP Enterprise Switch MIBs and Environmental Traps | |||
| RADIUS (RFC 2138), Telnet (RFC 854), TFTP client (RFC 783), SSH v1.5, SCP v1.5, NTP v2 (RFC 1119), BootP client (RFC 2132), and XModem | |||
| Network Transfer Rate |
10 Base-T (half-duplex) | 10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (half and full-duplex) | 2000 Mbps | ||
| 1000 Base-SX (full-duplex) | 2000 Mbps | ||
| Connector | 12 RJ-45, 2 DB-9 (C-GbE2
Interconnect Kit) 8 LC fiber, 4 RJ-45, 2 DB-9 (F-GbE2 Interconnect Kit) |
||
| EMI | FCC Class A | ||
| ICES-003 Class A | |||
| AS/NZS 3548 Class A | |||
| VCCI Class A | |||
| Safety | UL/CUL Listed Accessory | ||
| CE | |||
| Power Requirements |
48VDC: 2040 mA, 98 W
maximum (per interconnect switch without Storage Connectivity Kit) 48VDC: 2355 mA, 113 W maximum (per interconnect switch with Storage Connectivity Kit) |
||
| Temperature Range |
Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative Humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature |
Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa. | |||
|
|
|||
| Operating and Performance Specifications for CGESM Interconnect Switch |
Dimensions |
Height |
10.405 in (26.43 cm) |
| Width |
1.6 in (4.06 cm) |
||
| Depth |
28 in (71.12 cm) |
||
| Weight | 11.5 lb/5.2 kg per interconnect switch | ||
|
Performance |
28 Gbps Maximum Forwarding Bandwidth. 38.7mpps Maximum Forwarding Rate (64 Byte Packets) | ||
| 9018Bytes Jumbo Frames MTU | |||
| Non-blocking architecture. Wire Speed Performance on all ports | |||
| Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support | |||
|
Forwarding Mode |
Store and forward | ||
| MAC Addresses | 8000 MAC/physical address Table Size | ||
| Memory | 128MB DRAM Memory. 16MB Flash Memory | ||
| Compliance | IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3ad, IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and, IEEE 802.1D Spanning-Tree Protocol, IEEE 802.1p CoS Prioritization, IEEE 802.1Q VLAN, IEEE 802.3 10BASE-T specification, IEEE 802.3u 100BASE-TX specification, IEEE 802.3ab 1000BASE-T specification, IEEE 802.3z 1000BASE-X specification | ||
| RMON I and II standards, SNMPv1, SNMPv2c, and SNMPv3 | |||
| (RFC1493) , CISCO-CDP-MIB, CISCO-CLUSTER-MIB, CISCO-CONFIG-MAN-MIB, CISCO-ENTITY-FRU-CONTROL-MIB, CISCO-ENVMON-MIB, CISCO-FLASH-MIB, CISCO-FTP-CLIENT-MIB, CISCO-IGMP-FILTER-MIB, CISCO-IMAGE-MIB, CISCO IP-STAT-MIB, CISCO-MAC-NOTIFICATION-MIB, CISCO-MEMORY-POOL-MIB, CISCO-PAGP-MIB, CISCO-PING-MIB, CISCO-PROCESS-MIB, CISCO-RTTMON-MIB, CISCO-STP-EXTENSIONS-MIB, CISCO-SYSLOG-MIB, CISCO-TCP-MIB, CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB, CISCO-VLAN-MEMBERSHIP-MIB, CISCO-VTP-MIB, ENTITY-MIB, ETHERLIKE-MIB, IF-MIB (in and out counters for VLANs are not supported), IGMP-MIB, OLD-CISCO-CHASSIS-MIB, OLD-CISCO-FLASH-MIB, OLD-CISCO-INTERFACES-MIB, OLD-CISCO-IP-MIB, OLD-CISCO-SYS-MIB, OLD-CISCO-TCP-MIB, OLD-CISCO-TS-MIB, RFC1213-MIB (per the agent capabilities specified in the, CISCO-RFC1213-CAPABILITY.my), RFC1253-MIB, RMON-MIB, RMON2-MIB, SNMP-FRAMEWORK-MIB, SNMP-MPD-MIB, SNMP-NOTIFICATION-MIB, SNMP-TARGET-MIB, SNMPv2-MIB, TCP-MIB, UDP-MIB | |||
| 1000BASE-T ports, 1000BASE-X (SFP), 1000BASE-SX | |||
| Network Transfer Rate |
10 Base-T (half-duplex) | 10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (half and full-duplex) | 2000 Mbps | ||
| 1000 Base-SX (full-duplex) | 2000 Mbps | ||
| Connector | 4 SFP, 2 RJ-45 10/100/1000 T/TX/T, 1 DB-9 | ||
| EMI | FCC Part 15 Class A | ||
| EN 55022: 1998 (CISPR22)
EN 55024: 1998 (CISPR24) CNS 13438 Class A MIC CD MIC |
|||
| AS/NZS 3548 Class A CE | |||
| VCCI Class A | |||
| Safety | UL to UL 60950, Third
Edition C-UL to CAN/CSA C22.2 No. 60950-00, Third Edition TUV/GS to EN 60950:2000 CB to IEC 60950 with all country deviations NOM to NOM-019-SCFI |
||
| CE Marking | |||
| Power Requirements |
-48VDC: 1050 mA, 125 W maximum (per interconnect switch) | ||
| Temperature Range |
Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative Humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature |
Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa. | |||
|
|
|||
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
|
|
|
|||
|
© Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |