Overview
|
HP Modular Cooling System | ||
![]() | ||
|
|
||
| What's New |
|
|
|
| At a Glance |
|
|
|
Models
| Site Preparation | |
| HP Modular Cooling System Water Hook-up Kit |
AF079A
|
| HP MCS Site Preparation Service NOTE: Use Per Event Support and Consulting Service http://h20219.www2.hp.com/services/cache/11077-0-0-225-121.aspx. |
|
| NOTE: The Modular Cooling System Water Hook-up kit can be ordered ahead of the MCS for site preparation purposes. The kit contains set of 1.25 inches (31.8mm) Quick-disconnect couplings, non-rust, Parallel and Parallel-to-Tapered adapter included to address regional differences. | |
| Modular Cooling System (MCS) | |
| HP Modular Cooling System (WW) CTO ready |
AF098A
|
| HP
10642 G2 Rack Rear Extension Kit NOTE: Extension kit is required when racking p-Class Blade enclosure combined with Monitored PDU's. |
AF058A
|
| MCS
Onsite Installation NOTE: Install MCS per the product user installation manual. All MCS units ship with shock pallet for CTO. |
UE005E
|
| NOTE: The Rack Rear Extension kit is required when racking the HP c7000 Enclosure in conjunction with an HP Monitored PDU. | |
| NOTE: The purchase of HP Modular Cooling System (P/N AF098A) includes 10642 G2 rack and MCS unit attached. | |
| NOTE: A loaded MCS unit should only be moved by professional movers. |
|
|
Standard Features
| NOTE: For a brief, printer friendly data sheet that describes this product and informs you of the essential capabilities and specifications, please visit: http://h71028.www7.hp.com/ERC/downloads/4AA0-3604ENW.pdf. | |
| Product Description |
HP Modular Cooling System or MCS is designed for high density server
and blade deployments. It re-circulates and cools the hot server exhaust
air through heat exchangers residing in the MCS unit. The air is then
expelled in front of the enclosed rack at a much lower temperature providing
sufficient cool air for a load of 35kW of servers or blades. The MCS is now CTO capable with a dynamic load capacity of 2000 Lbs. For HP CTO services go to http://h20219.www2.hp.com/services/cache/119416-0-0-225-121.html?jumpid=reg_R1002_USEN] NOTE: A loaded MCS unit should only be moved by professional movers. |
|
|
|
| HP 10000 G2 Series Rack |
All HP rack-mountable products are designed to fit our industry-standard 19-inch wide racks. Racks and rack-mountable components are typically described using "U" measurements. One "U" is 1.75" (44.45 mm) high. |
The
MCS ships attached to a specially adapted 42U 10000 Series G2 rack 600mm wide
(10642). This sturdy, industrial-strength rack series offers the following features:
| |
| HP MCS Key Features |
|
|
| |
| Industry Standard Support |
All rack products are 19 inch RETMA standard and will support select third-party equipment. For additional rack information, please refer to the HP 10000 G2 Series rack QuickSpecs at: http://h18004.www1.hp.com/products/servers/proliantstorage/racks/10000series.html |
| | |
| Components |
The following brick level options/components do not have individual HP Care Pack Services. These items will be included in product HP Care Pack Services into which they are installed. | ||||
| Disk Drives | Tape Drives | CD/DVD ROM | SCSI Hubs in SBBs | Adapters | |
| Bus Converters | Backplane RAID Controllers | Power Supplies | Cabling | Fans | |
| | |||||
| Service and Support Offerings (HP Care Pack Services) |
HP Modular Cooling System: One year warranty, parts only (1-0-0) |
Care
Pack services provide a range of life cycle support options that let you choose
the service levels that meet your business requirements, from basic to mission-critical.
NOTE:
For more information on HP Care Pack services, contact any of our worldwide sales
offices or resellers or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack |
|
|
Related Options
| NOTE: This is a list of supported options. Some may be discontinued. | ||
| Rack Light Kit | 110V/220V Rack Light Kit (supports
10000 Series racks) NOTE: This neon light kit is mounted inside the rack and used to provide light to the rear section of the rack. |
361589-B21
|
|
|
||
| 9000/10000 Grounding Kit | 10000 G2 Rack Grounding Kit | AF074A |
| | ||
| Cable Management | Cable Management "D" Rings Kit | 168233-B21 |
| Hook and loop strips (50 pk) | 379820-B21 | |
| | ||
| Universal 1U Filler Panels (Carbon Graphite) | HP 10pk Carbonite 1U Universal Filler Panel |
AF070A
|
| HP 100pk Carbonite 1U Universal Filler Panel |
AF071A
| |
| | ||
| Rack Drawer | 2U Universal Drawer | 361591-B21 |
| Rack Shelves | 150 lbs (68 kg) Fixed Utility Shelf | 253449-B21 |
| 220 lbs (100 kg) Sliding Shelf | 234672-B21 | |
| | ||
| Cable Trays Kits | Rack Top Cable Tray, 600W, 8-Pack | 383982-B21 |
| Rack to Rack Adjustable Cable Tray, Aisle Transfer Bridge | 383984-B21 | |
| | ||
| Rear Extension Kits | 10642 G2 Rear Extension Kit (155mm) NOTE: The 10642 G2 extension kit is required when using HP monitored PDU's. |
AF058A |
| | ||
| Service and Support Offerings (HP Care Pack Services) | Hardware Services On-site Service | |
| Next
Business Day On-site Service, 5-Day x 9-Hour Coverage, 3 Years, Electronic |
UE001E | |
| 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic | UE002E | |
| 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic | UE003E | |
| 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic | UE004E | |
| Installation Services | ||
| MCS Onsite Installation, (Install MCS per the product user installation manual, BTO MCS units only, no CTO units) | UE005E |
|
|
Technical Specifications
| MCS Specifications | ||
| Dimensions | Height in U | 42U |
| Maximum Height | 78.7 in (1,999 mm) | |
| Maximum Width | 35.8 in (909 mm) | |
| Maximum Depth | 51 in (1,270 mm) | |
| Shipping Height (on skid) | 88.5 in (2248mm) | |
| Shipping Width (on skid) | 48 in (1220 mm) | |
| Shipping Depth (on skid) | 70 in (1778mm) | |
| Ramp length | 103 in (2616mm) | |
| Total length required for offloading MCS | 20.25 ft (6.17m) | |
| Weight | Net (including rack) | 1190 lbs (540 kg) |
| Shipping | 1370 lbs (621.4 kg) | |
| Load | Static | 2000 lbs (908 kg) |
| Dynamic (CTO) weight allowed | 2000 lbs (0 kg) | |
| Color | Graphite Metallic | Doors |
| Carbon | Frame | |
| Hot Swap Components | Heat exchangers | Yes |
| Fans | Yes | |
| Cooling | Cooling agent | Primary or auxiliary chilled water supply |
| Condensate evacuation tube | Yes | |
| Air temperature regulation | Yes | |
| Heat exchangers | 3 | |
| Fans | 3 | |
| Rack Front door | Transparent polycarbonate insert behind mesh | |
| Rack Rear doors (split) | Solid, no mesh | |
| Chilled water connections | Bottom rear | |
| MCS mounting location | Left hand side | |
| Side panels included | Yes | |
| Max Cooling capacity | 35kW | |
| Air Temperature to servers | Settable, suggested at 68-77 °F ( 20-25°C) | |
| Air Flow to servers | 2750 CFM Max | |
| Recommended Chilled Water inlet temperature | 45.0 °F ( 7.00 °C) | |
| Maximum Chilled Water Flow Rate | 20 gpm (1.27 lps) | |
| Chilled Water Pressure Drop | 25 psid | |
| Water connections | 1.25 in (31.8mm) | |
| Coupling type | 1.25 in (31.8mm) Quick-disconnect coupling, Parallel (parallel-to-tapered adapter included in AF079A) | |
| Flexible hose length (pre-installed) | 36 in (914mm) | |
| Pipe thread | Parallel (parallel-to-tapered adapter included) | |
| Power Input | Nominal Input Voltage | 208-240 VAC + - 10% |
| Frequency range (min-max) | 50/60 Hz | |
| Input Power | 2000 Watts Max | |
| Single phase | Yes | |
| Rated line current | 15 A per line cord | |
| Max inrush current | 54 A peak for 20 ms per line cord | |
| Dropout carry through time at min voltage | 20 ms | |
| Circuit breaker rating | 20A per line cord | |
| Power factor correction | >0.98 at all loads | |
| Ground leakage current (mA) | <3.0 (mA) per line cord | |
| Input Connections USA, Japan | NEMA L6-20P | |
| Input Connections International | IEC309 (16 Amps) | |
| Power Cords | 2 (for redundancy) | |
| Power input redundancy | Yes, with auto failover switch | |
| Environment | Room temperature requirements | 41.0 °F (5°C) Min to 95.0 °F (35.00
°C) Max |
| Humidity Range | Allowable 20%-80% Recommended 40%-55% |
|
| Environmental Monitoring | Air temperature to servers control | Yes |
| Water-In temperature monitor | Yes | |
| Communications & Management | Control panel | Multi-function LCD status and control console |
| SIM 5.0 Integration | Yes, via SNMP traps | |
| RJ 45 Plug | 1 | |
| Certifications | Regulatory Approvals | UL Listing 484, CUL Canadian std. 22.2 No.236 EN61000-3-2 EN61000-3-3 Flicker EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 CB report to IEC 60950-1 TÜV / GS EN 60335-1 (according to 60335-2-40) |
| Warranty | Standard MCS Warranty | 1-0-0 |
| Standard Rack Warranty | 3-0-0 | |
|
|
||
|
Environment-friendly Products and Approach |
End-of-life Management and Recycling | Hewlett-Packard offers end-of-life HP product
return, trade-in, and recycling programs in many geographic areas. For trade-in
information, please go to http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will be
recycled, recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
|
|
||
| © Copyright 2008 Hewlett-Packard Development
Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |