|
|
Overview
|
HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter |
|
| The HP NC380T server adapter
is the industry's first PCI Express dual port multifunction network adapter
supporting TOE (TCP/IP Offload Engine) for Windows, and iSCSI (Internet
Small Computer System Interface) over a single network connection. Each
port on the NC380T is a four lane (x4) serial device designed for PCI Express
slots. The NC380T comes with a total of 184KB onboard memory.
In addition to its multifunction capabilities, the NC380T ships with all the advanced server features that ProLiant customers have come to expect, such as support for failover and load balancing, Pre-Boot Execution Environment (PXE), large send offload capability, multiple VLAN tagging, and auto-negotiated 10/100/1000Mbps Ethernet speeds. |
|
![]() |
![]() |
|
|
|
| Models | |
| HP NC380T PCI Express Dual Port
Multifunction Gigabit Server Adapter NOTE: Supported on a Full Length-Full Height slot only |
394795-B21
|
|
|
|
| Kit Contents |
|
|
|
|
| NOTE: For a brief, printer friendly data sheet that describes this product and informs you of the essential capabilities and specifications, please visit: http://h71028.www7.hp.com/ERC/downloads/5983-0738EN.pdf. | |
| Standard Features | |
| Server Support |
ProLiant DL (rack-optimized):
ProLiant ML (expansion-optimized):
NOTE: This is a list of supported servers. Some may be discontinued. |
|
|
|
| Performance | |
| Gigabit Ethernet Throughput | 10/100/1000Mbps Ethernet transfer rate delivers outstanding network performance that improves response time and removes bottlenecks across the entire network. |
|
|
|
| TCP/IP Protocol Offloading |
TCP/IP Offload Engine (TOE) for Windows moves the processing of data in the TCP protocol stack from the server CPU to the network card, freeing CPU cycles for other duties. The NC380T supports TOE when Windows TOE Chimney is installed. With TOE, network communications are improved, and server efficiency is increased. |
|
|
|
| Accelerated iSCSI |
Accelerated iSCSI allows the NC380T
to multi-function both as a network adapter and as a storage host bus adapter,
thereby providing access to storage boxes and to servers over a single connection.
Additionally, the NC380T offloads the iSCSI software to the hardware for
improved performance. Accelerated iSCSI on 1GbE multifunction server adapters purchased as options ships as a standard feature, at no additional charge. |
|
|
|
| Load Balancing | Transmit Load Balancing (TLB) and Switch-Assisted Load Balancing (SLB) are two advanced features used to build a bigger pipe for improved networking bandwidth. These port bonding techniques enable users to install up to two NC380T adapters in a ProLiant server and aggregate their throughput up to a theoretical maximum of four Gigabits per second full-duplex transmission. The NC380T can be configured to work with other NC-series Ethernet server adapter teams supported on ProLiant servers. |
|
|
|
| Checksum and Segmentation Offloads and Interrupt Coalescing | The NC380T features TCP Checksum Offloads as well as TCP Segmentation Offloads and Interrupt Coalescence. These features reduce the load on the CPU for overall improved system response. Interrupt Coalescence is a feature that groups multiple packets and issues a single interrupt to the host. This process improves host efficiency. |
|
|
|
| Scalability and Reliability | |
| Tri-Speed Support | Because the NC380T supports 10Mbps Ethernet and 100Mbps Fast Ethernet in addition to Gigabit Ethernet, users are guaranteed end-to-end protocol support across their enterprise. Like all HP server adapters, the NC380T adheres to industry open standards, insuring that it will perform seamlessly with any network devices that also support IEEE standards. |
|
|
|
| Network Fault Tolerance (NFT) | Network Fault Tolerance, sometimes called "failover" or "NIC redundancy", allows for the installation of multiple NC380T server adapters or other network adapters so that the active device can be backed up by a redundant adapter to improve availability. The HP teaming utility also allows users to specify that when a failed adapter is fixed and replaced, the original adapter resumes its function as the primary network connection. |
|
|
|
| Network Management | |
| Auto-negotiation | The NC380T automatically senses the speed of the device to which it is attached. It also automatically configures for half or full duplex, depending on the duplex mode of the switch, hub, or router at the other end of the cable. |
|
|
|
| Management Support |
Like all HP server adapters, the NC380T ships with drivers and agents that can be managed from all versions of HP Systems Insight Manager, as well as using any management application that supports SNMP. |
|
|
|
| Server Integration |
HP Systems Insight Manager can recognize the NC380T individually or in port-bonded teams, and can collect and report SNMP statistics on the adapter events. Additionally, Integrated Management Log (IML) support is provided by the NC380T for critical event logging on HP servers. |
|
|
|
| Configuration Utilities |
Each NC380T ships with a set of utilities that allow the user to:
|
|
|
|
| LED Indicators |
Bracket LED indicators show link integrity, network activity, and network speed for easy troubleshooting. |
|
|
Service and Support, HP Care Pack, and Warranty Information
| Warranty |
Additional information regarding worldwide limited warranty and technical
support is available at: |
|
|
|
| Support Services |
Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware and software services are available
including:
NOTE: For more information on HP Care
Pack services, contact any of our worldwide sales offices or resellers
or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack |
|
|
Related Options
| Gigabit Server Adapters | HP NC110T PCI Express Gigabit Server Adapter |
434905-B21
|
| HP NC112T PCIe Gigabit Server Adapter | 503746-B21 | |
| HP NC360T PCI Express Dual Port Gigabit Server Adapter |
412648-B21
|
|
| HP NC364T PCI Express Quad Port Gigabit Server Adapter |
435508-B21
|
|
| HP NC373F PCI Express Multifunction Gigabit Server Adapter |
394793-B21
|
|
| HP NC373T PCI Express Multifunction Gigabit Server Adapter |
394791-B21
|
|
| HP NC375T PCI Express Quad Port Gigabit Server Adapter | 538696-B21 | |
| HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter | 458492-B21 | |
|
|
||
| 10 Gigabit Server Adapter | HP NC522SFP Dual Port 10GbE Server
Adapter NOTE: A minimum of two Gigabytes (2 GB) of server memory is required per each NC522SFP adapter. NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately. |
468332-B21
|
| HP NC524SFP Dual Port 10GbE Server
Adapter NOTE: A minimum of two Gigabytes (2 GB) of server memory is required per each NC524SFP module. NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately. |
489892-B21
|
|
|
Technical Specifications
| Compliance | IEEE 802.3-2002, 802.3ab, 802.3ad, 802.1Q | ||
| PCI Express ver 1.0a | |||
| ACPI ver 2.0 | |||
|
General Specifications |
Communications Processors | Broadcom 5706 (two) | |
| On-board memory | 184KB | ||
| Data rate | 10/100/1000 Mbps, Half- and full-duplex | ||
| Data path |
Four lane (x4) PCI Express compatible with x1, x4, x8, and x16 PCI Express slots | ||
| Interrupt levels | INTA | ||
| Connectors | RJ-45 (two) NOTE: Port enumeration on NC380T is bottom up i.e. the port nearest to the gold teeth is port #1 and the port near the top of the adapter is port #2. |
||
| Distance | Up to 328 ft (100 m) | ||
| Wiring | Category 5 or better UTP | ||
| Dimensions (L x W) | 7.44 x 4.37 in (18.9
x 11.1 cm) without bracket NOTE: Supported on a Full Length-Full Height slot only. |
||
|
Power and Environmental Specifications |
Operating | Temperature | 32° to 131° F (0° to 55° C) |
| Humidity | 10% to 90% non-condensing | ||
| Non-operating | Temperature | -40° to 185° F (-40° to 85° C) | |
| Humidity | 5% to 95% non-condensing | ||
|
Power requirement |
Operating Voltage:
12V +/- 8% Maximum: 1.05A @ 12V(DC) |
||
|
Emissions Classifications |
FCC Class B | ||
|
Agency Approvals |
USA | FCC (CFR 47 part 15) and UL 60950 | |
| Canada | ICES-003 and CSA60950 | ||
| Japan | VCCI | ||
| Korea | MIC (RRL), EMC Registration | ||
| Australia | ACA, AS/NZS3548/EN55022:1998, EN55024:1998 | ||
| EU | EN55022:1998 (CISPR 22), EN55024:1998, and IEC60950:1999 (EN60950:2000) | ||
| Operating System Support | Standard Gigabit Ethernet |
NOTE: For more Linux OS support & certification information, please visit our the ProLiant & BladeSystem Server Linux matrix: http://h18004.www1.hp.com/products/servers/linux/hplinuxcert.html |
|
| TCP/IP Offload |
|
||
| Accelerated iSCSI |
|
||
|
|
|||
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
|
|
||
|
© Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Windows is a US registered trademark of Microsoft Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |