contents
 Overview      HP Integrity rx7640 Server Flexible Advantage Starter (FAST) Configurable Bundles      Standard Features      Configuration      Upgrades      Technical Specifications line.gif (50 bytes)

Overview

HP Integrity rx7640 Server

 

 

1.Cell Boards (2)4.N+1 redundant hot-swap fans (2)
2.Hot-plug disks (4)5.2 Independent PCI power supplies
3.2N redundant hot-swap system power (2)6.Removable DVD or DAT

 

 

1.N+1 PCI cooling fans5.Dual-grid 2N redundant power inputs
2.System backplane (right side)6.Hot-swap redundant fans
3.Core I/O7.15 Hot-plug PCI-X slots
4.Power cord retention bracket  

At A Glance
HP Integrity rx7640 Server Product Number (base system)

AB312A

 
Standard System Features
  • HP UX 11i v3 and HP UX 11i v2 operating system
  • Microsoft Windows Server 2008 for Itanium-based systems and Windows Server 2003 Enterprise and Datacenter Editions
  • Linux RHEL AS 5 and AS 4 and SLES 10 SP 1. Mad9M rx7640 configuration not supported.
  • OpenVMS V8.3 1H1 or higher (for Montvale). Mad9M rx7640 configurations not supported.
  • One External Ultra320 LVD SCSI channel (a second Ultra320 SCSI port is available if a Smart Array card is used to access internal disk drives)
  • Four internal SCSI controllers
  • Two GbE LAN ports (with auto speed sensing)
  • Management Processor technology with Integrated LAN console
  • 100Base T Management LAN for LAN console
  • Rack mountable into HP 19 inch cabinets (factory or field integration)
  • Rack mountable into some third party cabinets
  • One or Two hardware partitions (nPartitions)
  • Factory integration of CPUs, memory, disk drives, removable media drives, and I/O cards
  • HP site planning and installation
  • One year warranty with next business day on site service response
  • Owner's Guide and General Usage media set
contents
 Overview      HP Integrity rx7640 Server Flexible Advantage Starter (FAST) Configurable Bundles      Standard Features      Configuration      Upgrades      Technical Specifications line.gif (50 bytes)

HP Integrity rx7640 Server Flexible Advantage Starter (FAST) Configurable Bundles

HP Integrity rx7640 Server Flexible Advantage Starter (FAST) Configurable Bundles
The Flexible Advantage STarter base systems for the HP Integrity rx7640 Server allow for faster configurations due to the semi configured system bundles. Configurations built from FAST base systems will have substantially lower prices than systems built from the parts.
 
HP Integrity rx7640 Server FAST Configurable Bundles
Product Number*
Number of dual core Itanium processors
Number of Cell Boards in bundle
Number of Core I/O Cards in bundle
AB447A
2 (2P/4C)
1
1
AB448A
4 (4P/8C)
1
1
AB450A
8 (8P/16C)
2
1
* Includes base chassis and power supplies.
contents
 Overview      HP Integrity rx7640 Server Flexible Advantage Starter (FAST) Configurable Bundles      Standard Features      Configuration      Upgrades      Technical Specifications line.gif (50 bytes)

Standard Features

Minimum System
  • One active core in an Intel Dual core Itanium (1P/2C) processor
  • One processor per cell board (Dual core Itanium only requires one active core per cell board)
  • One cell board
  • 4 GB memory (1 pair of 2 GB DIMMs)
  • One core I/O (included; not configurable)
  • One internal DVD drive for OpenVMS and Windows
  • Two power cords
  • Eight hot plug 33 /66 /133 /266 MHz 64 bit PCI X slots or eight mix of hot plug 64 bit PCI X and PCIe x8 IO slots with adaptive signaling technology

Maximum Server Capacities
  • Eight Intel Dual core Itanium (8P/16C) processors
  • Four processors per cell board
  • Two cell boards
  • 256 GB memory (16 pairs of 8 GB DIMMs)
  • Two core I/O
  • Four power cords, providing 2N power and dual grid support
  • Four internal hot plug LVD SCSI disks
  • One half height removable media bay. Configure with one DVD+RW or one DAT (or optionally, two slimline DVD devices)
  • 16 hot plug 33 /66 /133 /266 MHz 64 bit PCI X slots or 16 mix of hot plug 64 bit PCI X and PCIe x8 IO slots with adaptive signaling technology)

Standard System Features
  • HP UX 11i v3 and HP UX 11i v2 operating system
  • Microsoft Windows Server 2008 for Itanium-based systems and Windows Server 2003 Enterprise and Datacenter Editions
  • Linux RHEL AS 5 and AS 4 and SLES 10 SP 1. Mad9M rx7640 configuration not supported.
  • OpenVMS V8.3 1H1 or higher (for Montvale). Mad9M rx7640 configurations not supported.
  • One External Ultra320 LVD SCSI channel (a second Ultra320 SCSI port is available if a Smart Array card is used to access internal disk drives)
  • Four internal SCSI controllers
  • Two GbE LAN ports (with auto speed sensing)
  • Management Processor technology with Integrated LAN console
  • 100Base T Management LAN for LAN console
  • Rack mountable into HP 19 inch cabinets (factory or field integration)
  • Rack mountable into some third party cabinets
  • One or Two hardware partitions (nPartitions)
  • Factory integration of CPUs, memory, disk drives, removable media drives, and I/O cards
  • HP site planning and installation
  • One year warranty with next business day on site service response
  • Owner's Guide and General Usage media set

High Availability
  • N+1 Hot swap cooling
  • Redundant and hot swap power supplies
  • Cell Hot plug (implemented as dynamic nPars in HP UX 11i v3)
  • Hot plug disks
  • 2N power inputs (redundant line cords/dual power grid support)
  • On line memory page deallocation
  • ECC protected SyncDRAM memory
  • Full parity protection of data and address buses
  • On chip CPU cache with ECC protection
  • Double Chip Spare
  • Dynamic Processor resilience and deallocation (CPU deallocation on failure)
  • On line addition and replacement of PCI I/O cards
  • UPS power management
  • Three independent Ultra320 buses to internal disks for mirroring across disks and controllers
  • Journal file system (HP UX)
  • Auto reboot
  • On line diagnostics and system health monitor
  • Microsoft Cluster Services for Microsoft Windows Server 2008 and Windows Server 2003 Enterprise and Datacenter Editions
  • HP StorageWorks Software for HP Integrity Servers running Windows Server 2008 and Windows Server 2003 Enterprise and Datacenter Editions. Includes Cluster Extension XP and EVA, Continuous Access, Business Copy and SQL Server Fast Recovery
  • HP OpenVMS Cluster Software

Security
  • Separate console LAN port for system management
  • Password protection on console port
  • Disablement of remote console ports

Internet Server Functions
  • Internet server (inetd)
  • Domain name server
  • Routing (OSPF, BIND, RIP, EGP, HELLO, gateD)
  • Network Time Protocol

Client Configuration Services
  • Automatic configuration for printers, PCs, workstations, and X terminals (DHCP, Bootp, tftp, rbootp)

Optional Web Services
  • Netscape Communication Server
  • Netscape Navigator

Email
  • Mail, MailX, ELM
  • Sendmail, MIME, SMTP, ESMTP

Remote Access Services
  • Telnet, ftp, anonymous ftp server
contents
 Overview      HP Integrity rx7640 Server Flexible Advantage Starter (FAST) Configurable Bundles      Standard Features      Configuration      Upgrades      Technical Specifications line.gif (50 bytes)

Configuration

The HP Integrity rx7640 Server is a symmetrical multiprocessing (SMP) server supporting up to eight high performance Intel dual core Itanium processors (90XX series or 91XXN series). Earlier single core "Mad9" processors are supported with certain limitations. The server supports HP's innovative sx2000 chip set. The rx7640 can be configured as a single SMP server or divided into two smaller, hardware partitioned (nPars), logical servers.

Cell Boards

A minimum of one and a maximum of two cells can be ordered in an HP Integrity rx7640 Server. Each cell can be purchased with up to four active Intel dual-core Itanium processors (90X0 series or 91X0N series) or in combination with Instant Capacity processors. The rx7640 can support a mix of 90X0 and 91X0N series processors; however, within a single cell, all processors must be identical

The HP Integrity rx7640 and HP Integrity rx8640 servers share the same cell board. The rp7410/rp7420/rx7620 cell boards cannot be carried forward to the rx7640 server.


Cell Details
  • 4 processor slots (supporting up to eight processor cores)
  • HP sx2000 cell controller
  • 16 DDR-2 Memory DIMM slots
  • DC-DC Power converters
  • Manageability and Processor Dependent Hardware Circuitry

Cell Board Configuration Rules
  • Cell boards are ordered individually
  • Minimum: 1 cell board
  • Maximum: 2 cell boards
  • Cell slot 1 must be loaded first

Intel Dual-core Itanium Details
  • 1.6 GHz
  • Level 3 cache: 24 MB
  • Level 2 cache: 1 MB instr + 256 KB data
  • Level 3 cache: 16 KB instr + 16 KB data
  • Single bit cache error correction
  • 44 bit physical addressing
  • 64 bit virtual addressing
  • 4 GB maximum page size
  • Intel Itanium 9150N (Montvale)
  • 1.6 GHz
  • Level 3 cache: 18 MB
  • Level 2 cache: 1 MB instr + 256 KB data
  • Level 3 cache: 16 KB instr + 16 KB data
  • Single bit cache error correction
  • 44 bit physical addressing
  • 64 bit virtual addressing
  • 4 GB maximum page size
  • Intel Itanium 9140N (Montvale)
  • 1.4 GHz
  • Level 3 cache: 12 MB
  • Level 2 cache: 1 MB instr + 256 KB data
  • Level 3 cache: 16 KB instr + 16 KB data
  • Single bit cache error correction
  • 44 bit physical addressing
  • 64 bit virtual addressing
  • 4 GB maximum page size
  • Intel Itanium 9120N (Montvale)
Processor Configuration Rules
  • The Intel dual core Itanium processor consists of two processor cores. You may order and upgrade a dual core Itanium processor in increments of one core (the second core in a processor being iCAP).
  • There must be at least one processor core active (the other core being iCAP) on each cell board.
  • On each cell board, processors must be installed in the following sequence 0, 2, 1, 3
  • HP Integrity rx7620 1.6 GHz 6 MB level 3 cache processors may be carried forward to rx7640 servers.
  • Intel single core Itanium processors (now obsoleted) and Intel dual core Itanium processors can be mixed in the same chassis as long as they are in separate hard partitions (requires the same chipset, sx1000 or sx2000).

Memory Configuration The memory DIMMs used in the HP Integrity rx7640 Server are sold in pairs and are custom designed by HP. Each DIMM contains DDR II chips with full ECC protection. DIMM sizes of 2 GB, 4 GB, and 8 GB are supported. Each HP Integrity rx7640 Server cell board supports up to 16 DIMM slots and 16 GB/s of peak memory bandwidth. HP 9000 rp7410/rp7420/rx7620 memory modules cannot be carried forward to the rx7640 server.

The HP Integrity rx7640 and HP Integrity rx8640 servers share the same 4 GB, 8 GB, and 16 GB memory products.


HP Integrity rx7640 Server Memory DIMMs
Memory Module size (Pairs)
rx7640 Product Numbers
HP Integrity rx7640 Server
Maximum Capacity Using a single DIMM Size
Single DIMM Size
4 GB
AB454A
64 GB
2048 MB
8 GB
AB455A
128 GB
4096 MB
16 GB
AB456A
256 GB
8192 MB
Bundle size
rx8640 Product Number
Equivalent Memory Module
Single DIMM Size
128 GB (16 x 4GB)
AH411A
Qty 16 of AB455A
4096 MB
128 GB (8 x 8GB)
AH412A
Qty 8 of AB456A
8192 MB
256 GB (32 x 4GB)
AH413A
Qty 32 of AB455A
4096 MB
256 GB (16 x 8GB)
AH414A
Qty 16 of AB456A
8192 MB
  
Memory Loading Rules
  • Memory must be installed in pairs - modules (2 DIMMs of equal density)
  • Memory modules (pairs of DIMMS) are available in three densities: 4 GB (2×2048MB), 8 GB (2×4096MB), and 16 GB (2×8192MB).
  • Memory bundle product numbers consist of DIMMS already qualified in the memory modules.
  • Minimum memory is 2 GB per cell
  • Maximum memory per system is 256 GB-using sixteen 16 GB memory modules (8 GB pairs) per system.
  • Larger DIMMs must be loaded first across a cell, followed by progressively smaller DIMM sizes.
  • On each cell board, Memory Pairs must be installed in the following order:
    (0A, 0B), (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B), (5A, 5B), (6A, 6B),(7A, 7B)
  • DIMM mixing other than recommended configurations is supported as long as the memory loading rules are followed

rx7640 Recommended Memory Configurations
Memory per Cell (GBs)
Number of DIMMs
Quad Echelon
2 GB
4 GB
8 GB
2
1
3
0
2
1
3
0
        OA, OB 1A, 1B 2A, 2B 3A, 3B 4A, 4B 5A, 5B 6A, 6B 7A, 7B
4 2     2 GB              
8 4     2 GB 2 GB            
16 8     2 GB 2 GB 2 GB 2 GB        
32 16     2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB
32   8   4 GB 4 GB 4 GB 4 GB 2 GB 2 GB 2 GB 2 GB
64   16   4 GB 4 GB 4 GB 4 GB 4 GB 4 GB 4 GB 4 GB
64     8 8 GB 8 GB 8 GB 8 GB 4 GB 4 GB 4 GB 4 GB
128     16 8 GB 8 GB 8 GB 8 GB 8 GB 8 GB 8 GB 8 GB
Performance Tuning Guidelines
  • For best performance, a cell should be configured with a multiple of eight DIMMs or four pairs (although the server will execute properly with an odd number of pairs). It takes eight DIMMs to populate both memory buses. Populating only one of the two memory buses on a cell board will deliver only half the peak memory bandwidth.
  • Load memory equally across the available cell boards.

Memory Latencies

There are two types of memory latencies within the HP Integrity rx7640 Server:
1. Memory latency within the cell refers to the case where an application either runs on a partition that consists of a single cell or uses cell local memory.
2. Memory latency between cells refers to the case where the partition consists of two cells and cell interleaved memory is used. In this case 50% of the addresses are to memory on the same cell as the requesting processor, and the other 50% of the addresses are to memory of the other cell.

The HP Integrity rx7640 Server average memory latency depends on the number of CPUs in the partition. Assuming that memory accesses are equally distributed across all cell boards and memory controllers within the partition, the average idle memory latency (load to use) is as show below:

Number of processors Per Partition Average Memory Latency
4- processor (single cell) ~185 ns
8- processor (two cell) ~249 ns
  
I/O Architecture

Components within the I/O subsystem are the I/O controllers, internal peripheral bay, and multifunction Core I/O. The figure below shows the basic block diagram of the I/O subsystem. The HP Integrity rx7640 Server I/O architecture utilizes industry standard PCI X, and PCI-express buses in a unique design for maximum performance, scalability, and reliability. To achieve maximum performance and availability, each PCI/PCI-X slot on the I/O board is controlled by its own Bus Converter ASIC and is also independently supported by its own half of the dual hot swap controllers. All PCI slots are designed to be compliant with PCI Rev.2.2, PCI-X Rev.2.0a, and PCI-express Gen1 specifications.

The PCI-X 2.0 I/O Backplane implemented an important change to power distribution to the I/O partitions. The PCI-X Power supply bricks have been redesigned to allow the pair of them to be N+1 redundant in operation. Both I/O partitions will sustain their operational state even if one of the PCI bricks has failed. All the PCI voltages will remain within the PCI specification. These power bricks are not part of the PCI-X I/O board assembly. They plug into the edge of the PCI-X I/O Backplane to provide power to the board and they are not backwards compatible with the previous PCI power bricks. Any PCI brick failures will be reported to the system so the failing brick could be hot swapped.

Two different IO expansion bays are supported in the rx7640 chassis:

BP1: PCI-X IO BAY:
The PCI-X board is two logically independent I/O circuits (or partitions) on one physical board:
Escalante 0 and its associated eight Gemini ASICs, Core I/O 0 and 8 PCI-X expansion slots form PCI-X I/O Partition 0. Escalante 1 and its associated eight Gemini ASICs, Core I/O 1 and 8 PCI-X expansion slots form PCI-X I/O Partition 1.

BP2: Combined PCI-X / PCI-e IO BAY:
The PCI-Express board comprises two logically independent I/O circuits (partitions) on one physical board: Escalante 0 and its associated four Gemini (PCI-X) , four Apollo (PCIe) ASICs, and their respective PCI/PCI-X/PCIe slots form PCI-Express I/O Partition 0 + Core I/O. Escalante 1 and its associated four Gemini (PCI-X) , four Apollo (PCIe) ASICs, and their respective PCI/PCI-X/PCIe slots form PCI-X I/O Partition 1 + Core I/O.

The internal peripheral bay supports up to four low profile disks and one removable media device (one removable media device can be configured with one DVD+RW or one DAT (or optionally, two slimline DVD modules). The internal disks are electrically divided into two pairs. SCSI controller chips located on each core I/O board set supports each pair of internal disks. This means that you must have both core I/O board sets in order to access both halves of the peripheral bay.


PCI Backplane

The HP Integrity rx7640 Server supports both PCI X 2.0 and PCI Express. Two different backplanes are available. The PCI X 2.0 backplane (AB160A) supports sixteen (16) PCI X slots. A combination PCI Express/PCI X 2.0 backplane (AD161A) supports eight (8) PCI X slots and eight (8) PCI Express slots. AD161A is not supported as an upgrade to earlier rx7640 models configured with Intel Itanium Mad9M series processors.

Each backplane contains two master I/O controller chips located on the backplane. Each I/O controller contains sixteen high performance 12 bit wide links, which connect to sixteen slave I/O controller chips supporting the PCI X or PCI Express card slots and core I/O. Two links, one from each master controller is routed through the crossbar backplane and is dedicated to core I/O. The remaining thirty links are divided among the sixteen I/O card slots. This one card per link architecture leads to greater I/O performance and higher availability. Each controller chip is also directly linked to a host cell board. This means that at least two cell boards, located in cell slots 0 and 1, must be purchased in order to access all sixteen I/O card slots. With one cell board, access to eight slots is enabled.

Eight of sixteen I/O card slots are supported by dual high performance fat links. Each link is capable of ~2 GB/s of bandwidth. Six of the sixteen I/O card slots are supported by dual high-performance links. Each link is capable of providing 1060 of bandwidth. This means that half of HP Integrity rx7640 Server I/O slots are capable of sustained 2.12 GB/s. Aggregate I/O slot bandwidth is ~23 GB/s. In addition, because each I/O slot has a dedicated bus, any slot can be "hot plugged" or serviced without affecting other slots. The hot plug operation is very easy, and can be done with minimal training and effort.


I/O Card Description
Product Number
Operating Environment
Special Notes
Mass Storage Host Bus Adaptors
 
HP-UX
Win
Linux
Open VMS
 
PCI 1 port 2x Fibre Channel
A5158A
Y
 
 
 
Obsolete
PCI 2 Gb Fibre Channel
A6795A
Y
 
 
 
Obsolete
PCI-X 266 1-port 4-Gb Fibre Channel
AB378B
Y
 
 
Y
 
PCI X 266 2 port 4 Gb Fibre Channel
AB379B
Y
Y
Y
Y
 
PCI 1 channel Ultra 160 SCSI
A6828A
Y
 
 
 
Obsolete
PCI 2-channel Ultra 160 SCSI
A6829A
Y
 
 
 
Obsolete
PCI-X 2-port Ultra 320 SCSI
A7173A
Y
Y
Y
Y
  
PCI-X 2-channel 2-Gb Fibre Channel
A6826A
Y
  
  
  
Obsolete
PCI-X 2-port 2-Gb Fibre Channel
AB466A
Y
Y
 
 
Cannot be factory integrated with AD167A or AD168A
PCI-X 1-port 2Gb Fibre Channel
AB467A
 
Y
 
 
Cannot be factory integrated with AD167A or AD168A
PCI-X 266 1-Port 4-Gb Fibre Channel
AB429A
 
Y
Y
 
 
PCI-X 1-Port 4Gb Fibre Channel
AD167A
 
Y
Y
 
Cannot be factory integrated with AB466A or AB467A in the same partition
PCI-X 2-Port 4Gb Fibre Channel
AD168A
 
Y
Y
 
Cannot be factory integrated with AB466A or AB467A in the same partition
PCIe 1-port 4Gb Fibre Channel (Emulex)
A8002A
 
Y
Y
 
Cannot be factory integrated with AB466A or AB467A in the same partition. Windows max (12); Linux max (8)
PCIe 2-port 4Gb Fibre Channel (Emulex)
A8003A
 
Y
Y
 
Cannot be factory integrated with AB466A or AB467A in the same partition. Windows max (12); Linux max (8)
PCIe 1-port 4Gb Fibre Channel (Emulex)
AD299A
Y
 
 
Y
OpenVMS maximum 8 per partition.
HP PCIe 2 port 4Gb Fibre Channel AD355A Y     Y OpenVMS maximum 8 per partition.
PCIe 2-port 4Gb Fibre Channel (Qlogic)
AD300A
Y
Y
Y
Y
HP-UX max (8); Windows max (8); Linux max (8); OpenVMS max (8) per partition
PCIe 1-port 4Gb Fibre Channel (Qlogic)
AE311A
 
Y
Y
 
Windows mad (12); Linux max (8)
 
I/O Card Description
Product Number
Operating Environment
Special Notes
Mass Storage Adaptors - Smart Array
 
HP-UX
Win
Linux
Open VMS
 
SmartArray 6402/128MB cache controller with factory integrated internal RAID 1 array
AB362A
 
Y
Y
 
Must be ordered with two (2) indentical HDD in the hard partition.
AB338A cables are included
Max (1) per partition
SmartArray 6404/256MB cache controller with factory integrated internal RAID 1 array
AB363A
 
Y
 
 
Must be ordered with two (2) indentical HDD in the hard partition.
AB338A cables are included
Max (1) per partition
SmartArray 6402/128MB cache controller
A9890A
Y
Y
Y
Y
Max (8) any combination of A9890A + AB262A. For OpenVMS, max (2) per partition
Order AB363A for SmartArray 6404 controller with factory integrated internal RAID
SmartArray 6404/1256MB cache controller
A9891A
Y
Y
 
Y
Max (8) any combination of A9891A + AB263A. For OpenVMS, max (1) per partition
Order AB363A for SmartArray 6404 controller with factory integrated internal RAID
SmartArray P600/256MB cache controller
337972-B21
 
Y
Y
 
Max (8)
For external storage only
512MB cache memory upgrade for SmartArray P600, 6402, and 6404
372538-B21
Y
Y
Y
Y
No factory integration
SmartArrayPCIe P800 SAS RAID controller
AD335A
Y
 Y
Y
OpenVMS maximum 8.
HP PCIe SC44Ge SAS Host Bus Adapter
AH303A
Y
 
 Y
Y
Max (8)
SmartArray E500 SAS HBA
AH226A
 
Y
Y
 
Battery pack is not supported at this time. Windows max (8); Linux max (4)
SmartArray Internal RAID cables
AB338A
 
Y
Y
 
Includes two (2) cables
One (1) cable required per SmartArray controller for field installation of internal RAID

 

 
I/O Card Description
Product Number
Operating Environment
Special Notes
Local Area Network (LAN) Adapters  
HP-UX
Win
Linux
Open VMS
 
PCI-X 1-port 10GbE
AB287A
Y
 
 
Y
Obsolete
HP PCI X 4 port 1000Base T Gigabit Adapter
AB545A
Y
 
Y
Y
OpenVMS max (3) per partition
HP PCI-X 1-port 1000Base-T
AD331A
Y
 
 
Y
 
HP PCI-X 1-port 1000Base -SX
AD332A
Y
 
 
Y
 
PCI 1-port 1000Base-T
A5230A
Y
 
 
 
Obsolete
PCI 1-port 1000Base-SX
A4926A
Y
 
 
 
Obsolete
HP PCI X 2-port 1000Base SX (optical) Gigabit Adapter
A7011A
Y
Y
Y
Y
Intel chip
PCI-X 1000Base-SX dual port
A9899A
 
Y
Y
 
Obsolete
PCI-X 1000Base-T dual port
A7012A
Y
 
 
Y
Intel chip
PCI-X 1000Base-T dual port
A9900A
 
Y
Y
 
Intel chip
HP PCI-X 266MHz. 10GigE SR (half height PCI-X card)
AD385A
Y
 
Y
Y
HP-UX max (2); Linux max (2); OpenVMS max (4) per partition
PCIe 2-port 1000Base T GbE
AD337A
Y
Y
Y
Y
HP-UX max (8); Windows max (12); Linux max (8); OpenVMS max (8) per partition. OpenVMS boot not supported
PCIe 2-port 1000Base SX GbE
AD338A
Y
Y
Y
Y
HP-UX max (8); Windows max (12); Linux max (8); OpenVMS max (8) per partition. OpenVMS boot not supported
HP PCIe 10Gbe SR card AD386A Y     Y  
HP NC364T PCIe 4-port 1000BaseT Gb Adapter
AD339A
y
 
 
Y
No OpenVMS boot support

 

 
I/O Card Description
Product Number
Operating Environment
Special Notes
Mulit-Function (Mass Storage/LAN) 
HP-UX
Win
Linux
Open VMS
 
PCIe 4Gb Fibre Channel / GbE T HBA comboAD221AY   HP-UX: max (8). HP-Ux v3 support only
PCIe 2-port 4-Gb Fibre Channel/2-port Gbe T HBA comboAD222AY   HP-UX: max (8). HP-Ux v3 support only
PCIe 2-port 4Gb Fibre Channel / 2-port Gbe-SX HBA comboAD393AY   HP-UX: max (8). HP-Ux v3 support only
PCIe 1-port 8Gb FC SR (Qlogic) HBA
AH400A
Y
    
PCIe 2-port 8Gb FC SR (Qlogic) HBA
AH401A
Y
    
PCI-X 2Gb Fibre Channel / 1000Base-SX
A9782A
Y
 
 
Y
OpenVMS max (4) per partition
PCI-X 2Gb Fibre Channel / 1000Base-T
A9784A
Y
 
 
Y
Obsolete
PCI-X 2-port U320 SCSI / 2-port 1000Base-T
AB290A
Y
 
 
Y
OpenVMS max (2) per partition
PCI-X 1000Base-T GigE / 1-port 4G Fibre Channel
AD193A
Y
 
 
Y
 
PCI-X 1000Base-T GigE / 2-port 4G Fibre Channel
AD194A
Y
 
 
Y
 

 

 
I/O Card Description
Product Number
Operating Environment
Special Notes
Wide Area Network (WAN) Adapters 
HP-UX
Win
Linux
Open VMS
 
2-port programmable serial interface (X25/Frame Relay/SDLC)
J3525A
Y
 
 
 
Order appropriate cable (RS-232-C; V.35; X.21/V11; RS-499; or RS-530
Must order at least one appropriate software products
X.25 License-to-Use (LTU)
J2793B
Y
 
 
 
 
SNAplus2 Link Server LTU
J6380AA
Y
 
 
 
Required for use with any of the SNAplus2 software products
SNAplus2 Enterprise Extender
J6378AA
Y
 
 
 
Order one per processor core
SNAplus2 APPN Node Server
J6382AA
Y
 
 
 
Order one per processor core
SNAplus2 3270/3179G Server
J6383AA
Y
   Order one per processor core
SNAplus2 RJE Server
J6384AA
Y
   Order one per processor core
SNAplus2 API Server
J6385AA
Y
   Order one per processor core
TN3270 System
J6381AA
Y
   Order one per processor core

 

 
I/O Card Description
Product Number
Operating Environment
Special Notes
Additional Interface Cards 
HP-UX
Win
Linux
Open VMS
 
HP PCI 8-port serial mux adapter
AD278A
Y
 
 
 
 
HP PCI 64-port serial mux adapter
AD279A
Y
 
 
 
Min 1, max 4 port modules AD280A and/or AD281A is required. AD280A and AD281A port modules can be intermixed.
HP 16-port RS-232 RJ45 port module
AD280A
Y
 
 
 
Power supplies required for third and fourth modules connected to AD279A
HP 16-port RS-232 DB25 port module
AD281A
Y
 
 
 
Power supplies required for third and fourth modules connected to AD279A
Cluster Interconnect Hyperfabric II
A6386A
Y
 
 
 
 
Cluster Interconnect PCI-X 2-port 4x Infiniband Fabric Host Channel Adapter
AB286C
Y
 
 
 
 
Cluster Interconnect PCIe 2-port 4x Infiniband Fabric Host Channel Adapter
AD313A
Y
 
 
 
No boot support
HP Lights Out Advanced KVM
AD307A
Y
Y
Y
Y
HP-UX, Linux, OpenVMS support USB only - no VGA support. Max (1) per partition
HP USB/VGA PCIK adapter
A6869B
Y
Y
Y
Y
HP-UX, Linux, OpenVMS support USB only - no VGA support. Max (1) per partition

 

Integrity Integrated Lights Out (iLO-2) Management Processor Functionality for sx2000-based Servers

Lights-Out remote management port with both HP 9000 command line interface and new iLO-2 web GUI interface. iLO-2 standard features are part of the iLO-2 management processor. iLO-2 advanced features are added with optional PCI card per managed partition (option AD307A).

Standard Features:

  • Password protected console ports
  • Console mirroring between all local, modem, LAN, and web consoles
  • Remote power up and power down control, per OS partition
  • Configurable remote access control
  • Interface to system monitoring and diagnostic hardware via an internal IC bus
  • System Event logs and event notification to system console-Provides connectivity, information, and support for HP UX tools (such as STM and EMS) to notify by email, pager and/or HP response centers.
  • Integration with HP management tools such as Systems Insight Manager
  • Secure Sockets Layer security on web console
    (LDAP is not yet available for this product)

Advanced Features, available through Integrity Lights Out Advanced / KVM card (option AD307A)
  • Physical VGA/USB 2.0
  • Integrated Remote Console (virtual Keyboard Video Mouse)
  • Virtual Media USB 1.1
    Card provides one physical VGA port and two physical USB ports, should be used instead of graphics/USB option A6869A. One card should be installed in each nPar where additional management features are required. Card cannot be used in systems without iLO-2 management processor firmware installed.

AD307A card Integrated Remote Console (virtual Keyboard Video Mouse) and virtual Media (read-only CD/DVD/ISO file) support per OS:


Operating System Integrated Remote Console (vKVM) Virtual Media
HP UX
not supported
supported
Windows
supported
supported
Linux
not supported
not supported
OpenVMS
not supported
supported
VGA port is supplied by an ATI ES1000 controller. Supported resolutions and refresh rates include:
Operating System Refresh Rate Maximum Resolution
Windows
75 Hz
640x480
Windows
75 Hz
800x600
Windows
75 Hz
1024x768
Windows
75 Hz
1280x1024
Windows
60 Hz
1600x1200
External Server Storage Connectivity

HP has the broadest, most robust server and storage line-up in the industry, providing exactly the right fit for every need. Refer to the Storage-Server matrix to see a matrix that highlights which storage device, server and operating system is interoperable.


Integrated Multifunction Core I/O

The HP Integrity rx7640 Server chassis supports up to two core I/O board sets. Each board set contains two cards (MP/SCSI and LAN/SCSI), which are installed in different locations. MP/SCSI cards are installed along the right rear vertical edge of the chassis. The LAN/SCSI cards are installed in the PCI card bay. The first core I/O board set will support up to two cell boards in the server and all I/O slots. For support of two hard partitions or for support of the third and fourth integrated disk drive, a second core I/O board set is required in the host system.

HP Integrity rp7410/rp7420/rx7620 Core I/O cards cannot be carried forward to the HP Integrity rx7640 server.

Both Core I/O board sets are identical. The "primary" and "secondary" Core I/O LAN/SCSI board is supported by a 530 MB/s link. In addition, in the "primary" core I/O, a SCSI controller from both the LAN/SCSI board and MP/SCSI board each support a single internal disk drive.

 
Each HP Integrity rx7640 Server core I/O board set provides the following features:
  • Management Processor: The management processor (MP), located on each MP/SCSI card, is a dedicated processor that simplifies and extends system management, and also enhances serviceability. The MP minimizes or eliminates the need for the system administrator to be physically at the system to perform tasks such as diagnostics, system management, or even hard resets. Here are some of the features enabled by the HP Integrity rx7640 Server management processor:
    • System management over the Internet or Intranet (telnet or web)
    • System console redirection
    • Console mirroring
    • System configuration for automatic restart
    • Viewing history log of system events
    • Viewing history log of console activity
    • Setting MP inactivity timeout thresholds
    • Remote system control
    • Remote power cycle (except for MP housekeeping power)
    • Viewing system status
    • Event notification to system console, e mail, pager, and/or HP Response Centers
    • Automatic hardware protection of critical environmental problems
    • Access to management interface and console(s) on LAN failure (modem required)
    • Remote resetting of hardware partitions
    • Forward progress indicator (Virtual front panel)
    • Out of band Manageability and PDC firmware update
    • Configure manageability and console security
    • SSL
  • External Management LAN port: 10/100Base T LAN port using an RJ 45 connector.
  • One External SCSI ports: Ultra320 LVD SCSI port for connections to mass storage or media. (A second U320 external port only available when internal drive off of LAN/SCSI is connected to Smart Array).
  • Two External 1GbE LAN ports.
  • Access to internal peripheral bay: The HP Integrity rx7640 Server internal peripheral bay is located at the top front of the system chassis. The peripheral bay holds up to four low profile hot plug disks and one half height removable media device ( One half height bay supports two devices in the case of optional slim line DVD's). Each HP Integrity rx7640 Server core I/O board set contains dual channel Ultra320 SCSI controller chips that support the SCSI devices in the internal peripheral bay. Each core I/O board set supports two internal disks. It is important to note that separate controllers and SCSI busses manage the two disks supported by the primary and secondary core I/O set (This is a change from the previous architecture in sx1000 based servers). If use of more than two internal disks is needed, the HP Integrity rx7640 Server will require both core I/O sets.

Core I/O Loading Rules

  • Minimum of one Core I/O board set (primary) must be purchased with each HP Integrity rx7640 Server
  • Load the Primary (1) MP/SCSI board into slot 1 and the LAN SCSI board into I/O cabinet 1 (slot 8).
  • MP/SCSI slot 0 and I/O cabinet 0 corresponds to Cell Board slot 0. MP/SCSI slot 1 and I/O cabinet 1 corresponds to Cell Board slot 1.
  • A cell board must be installed in slot 0 to enable use of Core I/O 0. Likewise, a cell board must be installed in slot 1 to enable use of Core I/O 1.
  • Access to two internal disk drives and one half height removable media bay is enabled with the installation of the first Core I/O board set (Primary).
  • The optional second Core I/O board set (secondary) must be ordered to enable hardware partitioning
  • The optional second Core I/O board set (secondary) must be ordered to enable access to the third/fourth internal disks
  • The optional second core I/O board set (secondary) must be ordered to enable using the optional slim line DVD's.

Internal Disk Drives

HP Integrity rx7640 Server supports up to four internal low profile hot plug disk drives.

Internal Disk Drive Specifications
Product NumberDisk CapacityRotational speedAverage seek time (read/write)Sustained Bandwidth
AD147A73 GB15,000 RPM3.6 msec (read); 3.9 msec (write)75 MB/s
AD210A146 GB15000 RPM3.6 msec (read); 3.9 msec (write)75 MB/s
AD265A300 GB15000 RPM3.6 msec (read); 3.9 msec (write)75 MB/s
HP Integrity rp7410/rp7420/rx7620 disk drives can be carried forward to the HP Integrity rx7640 server.

 

 

For HP UX:

  • Supported by MirrorDisk/UX across disk drives, controllers, and core I/O boards
  • Must order the second Core I/O board set to support more than two internal disk drives

For Windows:

  • An rx7640 customer need only order AB362A 0D1 in order to receive an SA6402 Smart Array card cabled and configured for RAID 1 mirroring in the factory. The AB362A product includes both the SA6402 Smart Array Card (A9890A) and the internal RAID cables (AB338A).
  • An rx7640 customer need only order AB363A 0D1 in order to receive an SA6404 Smart Array card cabled and configured for RAID 1 mirroring in the factory. The AB363A product includes both the SA6404 Smart Array Card (A9891A) and the internal RAID cables (AB338A).
  • The customer is limited to maximum of one AB362A or AB363A per partition.
  • The customer may order additional Smart Array controllers as add in cards for connection to external storage devices. When these products are ordered with option 0D1 they will be installed, but will not be connected to the internal HDDs. The supported Smart Array products (for external storage) on rx7640 are:
    • A9890A - SA6402
    • A9891A - SA6404
    • 337972-B21 - SA P600

Internal Removable Media
  • HP Integrity rx7640 Server contains one half-height removable media bay, which will support either a DVD+RW or DAT 72 drive or two slimline DVD+RW drives. Removable media drives are not hot plug capable.
  • DVD+RW drive provides enhanced features while preserving backward read compatibility with CD ROM. Data transfer rates of up to 6.75 MB/s are achieved with the DVD format; 4.8 MB/s can be achieved with the CD format.
  • A DVD drive is required for all OpenVMS and Windows configurations.
  • DAT drive has a maximum storage capacity of 72 GB with a peak transfer rate of 21.6 GB/hour compressed.
  • HP Integrity rp7410/rp7420/rx7620 removable media drives can be carried forward to the HP Integrity rx7640 servers
Internal Removable Media Specifications
Product Number Device Capacity Data transfer rate
AB351B1 DVD+RW    
AB400A DAT 72 GB  
AD013A2 Two slimline DVD+RW    
1Third party software (not included with AB351B) is required to support DVD write capability with Windows.
2The slimline DVD's require the second core I/O set.
I/O Configuration Rules The following table summarizes previously mentioned configuration rules pertaining to usage of I/O slots and internal peripherals.
 
Minimum Requirement
Configuration Minimum Number of Cells Minimum Number of Core I/Os
>7 I/O card slots or access to both I/O card bays 2 1
>2 internal disks or access to both pairs of disks 2 2
1 Internal half height Removable Media 1 1
2 Hard Partitions 2 2
2 Internal slim line DVD's 2 2
External Storage

HP has the broadest, most robust server and storage line up in the industry, providing exactly the right fit for every need. Refer to the Storage-Server matrix to see a matrix that highlights which storage device, server and operating system is interoperable.


AC/DC Power

DC Power Supplies
The HP Integrity rx7640 Server comes with two power supplies that provided dual grid (2N) protection. The hot swap design allows for the replacement of a failed power supply without interrupting server operation. All four power cords must be utilized to fully enable power supply hot swap. HP Integrity rp7410/rp7420/rx7620 DC power supplies can be carried forward to the HP Integrity rx7640 server

PCI Power Supplies
PCI power supply is now a redundant N+1 design. One PCI power supply failure will not affect the I/O bay since the remaining PCI power supply will power both I/O bays (this is an upgrade from the sx1000 based systems). PCI power supplies are hot swap capable (this is an upgrade from the sx1000 based systems). HP Integrity rp7410/rp7420/rx7620 PCI Power Supplies cannot be carried forward to the HP Integrity rx7640 server.

AC Power
The HP Integrity rx7640 Server contains four C20 power receptacle ports located at the bottom rear bulkhead. A minimum of two power cords must be used to maintain normal operation of the HP Integrity rx7640 Server. A second set of two cords can be added to improve system availability by protecting, for example, against power grid failures, accidentally tripped circuit breakers, or a failed power supply. The HP Integrity rx7640 Server hardware is capable of receiving AC input from two different AC power sources. The objective is to maintain full equipment functionality when operating from power source A and power source B or A alone or B alone. This capability is called "fault tolerant power compliance".

Although many HP Integrity rx7640 Server configurations can be sufficiently powered from a single 16 /20 amp branch circuit, the optimum configuration is to use one 16 amp (minimum) branch circuit per power cord. Due to the variety of 16/20 plugs used throughout the world, the HP Integrity rx7640 Server Ordering Guide offers a choice of plug options.

AC Power Consumption
The HP Integrity rx7640 Server power consumption will vary greatly depending on the hardware configuration and the input line voltages supplied at customer sites. Because of the disparity of line voltages throughout the world it's best to represent power consumption in VA (Volt Amperes). With power consumption being of high concern throughout the world, it's necessary to specify consumption in a couple of different ways.

Maximum Theoretical Power: or "Maximum Configuration" (Input power at the ac input expressed as Volt-Amps to take into account Power factor correction.)
The calculated sum of the maximum worst case power consumption for every subsystem in the server. This number will NEVER be exceeded by a functioning server for any combination of hardware and software under any conditions.

Marked Electrical Power: (Input power at the ac input expressed as Volt-Amps.)
The server Marked Electrical Power is the rating given on the chassis label and represents the input power required for facility ac power planning and wiring requirements. This number represents the expected maximum power consumption for the server based on the power rating of the bulk power supplies. This number can safely be used to size ac circuits and breakers for the system under all conditions.

Typical Maximum Power: or User Expected Maximum Power, "Typical Configuration" (Expressed as Volt-Amps.)
The measured maximum worst case power consumption. This number represents the larges power consumption that HP engineers were able to produce for the server with any combination of hardware under laboratory conditions using aggressive software applications designed specifically to work the system at maximum load. This number can safely be used to compute thermal loads and power consumption for the system under all conditions.
For further power consumption details, see the HP Integrity rx7640 Installation manual.


Configuration

HP Integrity rx7640 Server Fully Loaded Configuration

  • 8 Intel Dual core Itanium processors or 1.6 GHz Single core Itanium processors
  • 256 GB of memory
  • 14 PCI cards
  • 2 cell boards
  • 4 internal hard drives
  • 1 DVD drive
  • 2 core I/O board sets
  • 2 bulk power supplies.
  • Typical maximum power: 2171 VA (2128 W) (10.9 A @ 200 VAC across two cords)
  • Marked Electrical for the server: 2640 VA (12A @ 220 VAC across two cords)
  • Marked Electrical per line cord: 1320VA (6A @ 220 VAC across each cord)
  • Maximum Theoretical Power: 3231 VA (3166 W)

Power Distribution Units

60-amp Power Distribution Unit-

  • AF916A (NA/JPN) and AF917A (International) - supported in 10KG2 rack
  • E7683A (US) and E7684A (International) - supported in Rack System E

Customers who prefer the fewest higher amperage connections from their ac line current source to the HP Integrity rx7640 Server can use the 60 amp power distribution unit (PDU). The AF916A & AF917A PDU's contain 12 C19 outlets. The E7683A & E7684A PDU's contain 8 C19 outlets. For more details on PDU's, please see PDU sales collateral. This PDU is sold separately and can be ordered with any HP server solution.

The maximum amperage is 60 amps through the entire PDU and 20 amps per breaker. Both limits must be met. If each 60 amp PDU can support up to four HP Integrity rx7640 servers if the PDU is not mounted in the same rack. Up to three HP Integrity rx7640 servers can be supported if the PDU is mounted within the same rack.

For redundant power inputs, the second set of cords is added. If the second PDU is plugged into a second grid this configuration provides protection against:

  • Losing power from a single power grid
  • Accidental tripping of one or two circuit breakers
  • Accidental disconnect of a single PDU power cord
  • Accidental disconnect of up to four (two from each system) system power cords

30 amp Power Distribution Unit-

  • 252663 D75 (NA/JPN) and 252663 B33 (International)-supported for 10K G2 rack
  • E7681A (North America/JPN) and E7682A (International)-supported with Rack System E

A 30 amp Power Distribution Unit (PDU) is also supported with HP Integrity rx7640 Server. Rack configurations consisting of peripherals and only one HP Integrity rx7640 Server will likely be best supported with the 30 amp PDU. This PDU is sold separately and can be ordered with any HP server solution.

Unlike the 60 amp PDU, each 30 amp PDU can only support one HP Integrity rx7640 Server. The following configuration guidelines apply when using the 30 amp