Overview
|
HP UPS T1000 G2, T1500 G2 and R/T2200 G2 Models |
| The Tower UPS "G2" models are
the next generation HP tower UPSs with USB support. The new models are the
UPS T1000 G2, T1500 G2 and R/T2200 G2 respectively. These new UPSs are designed
to provide advanced power protection (or increased uptime and data corruption
avoidance) for servers, storage, computer equipment, and network environments.
Key benefits include increased power rating, intuitive front panel display, Enhanced Battery Management (EBM), prioritized shut-down, and hot-swappable batteries. Bundled with HP Power Manager management software, these UPSs also feature a serial and USB ports for data exchange with the host computer, remote shut-down, a three-year warranty and a $250,000 load protection guarantee. |
|
|
![]() |
![]() |
|
R/T2000 G2
|
T1000 G2 and T1500 G2
|
|
1. Battery Compartment
|
1. Battery Compartment
|
|
2. LED display
|
2. LED display
|
|
|
|
| Models | |
| HP T1000 UPS |
AF403A
|
| HP T1500 UPS |
AF406A
|
| HP R/T 2200 UPS |
AF409A
|
|
|
Product Highlights
| NOTE: For a brief, printer friendly data sheet that describes this product and informs you of the essential capabilities and specifications, please visit: http://h71028.www7.hp.com/ERC/downloads/4AA0-6982ENW.pdf. |
| Key Features | All G2 Models |
NOTE: Certain restrictions and exclusions apply. Consult the HP Computer Support Center for details. |
|
| R/T 2200 Only |
|
||
|
|
|||
| Easy Configuration via Enhanced Front Panel Display | Please see the line art drawing previously shown to identify the front panel with noted button functionality. | |
| | ||
| Investment Protection with Enhanced Battery Management | HP UPSs incorporate Enhanced Battery Management; an exclusive, patented technology that doubles battery service life, optimizes battery recharge time, and provides advance notice of pending battery failure. With Enhanced battery Management, you have a lower overall cost of ownership and receive the best in the industry protection for your critical equipment. |
| | |
| Intelligent Manageability | HP UPSs ship with HP Power Manager management software, which enables you to monitor and control HP UPSs locally or remotely. This software is a versatile, fully configurable, alert response tool that gives system administrators a full overview of the network's conditions. It enables you to monitor system status and power conditions, configure shut down timing, customize alert messages, and perform UPS diagnostic checks quickly and easily. | |
| | ||
| Ease of Maintenance with Hot-Swappable Battery | HP UPSs are designed with hot-swappable batteries. With simple access through the front panel. Users can safely install a new battery without ever powering down connected computer equipment. | |
| | ||
| R/T 2200 G2: Independently Controllable Load Segments | The R/T2000 G2 UPS models incorporate independently controllable load segments (groups of outlets) that allow for prioritized shutdown of multiple servers. Managed through the Power Management software, each individual load segment can be pre-configured by the system administrator to conduct a prioritized shutdown extending the runtime of your most critical servers. In addition, this feature promotes energy and power conservation by facilitating scheduled shutdown and startups during low usage such as weekends and holidays. | |
| | ||
| Compatibility | Compatible with all HP computer systems and servers ranging from individual workstations to distributed enterprise and other HP equipment (in tower form factor). | |
| | ||
| HP Quality | HP hardware qualification is the toughest in the industry. Extensive evaluation, testing, product improvement, and an unsurpassed warranty guarantee the highest level of system protection, electrical performance, product quality and compatibility. | |
|
| ||
| Kit Contents - UPS T1000 G2 |
|
|
|
| ||
| Kit Contents - UPS T1500 G2 |
|
|
|
| ||
| Kit Contents - UPS R/T2200 G2 |
|
|
|
| ||
| Warranty | HP UPSs are covered by a three-year
warranty, with the first year including parts and labor. Also, standard
on all HP UPS units is our exclusive Battery Pre-Failure Warranty, which
extends the advantage of a HP three-year, limited warranty by applying it
to the battery before it actually fails. This warranty is offered worldwide.
Specifically, the Pre-Failure Battery Warranty ensures that when customers
receive notification from HP Power Management Software that the battery
may fail, the battery is replaced free of charge under the warranty. NOTE: $250,000 Computer/Load Protection Guarantee is also provided |
|
|
Service and Support, Care Pack and Warranty Information
| HP Care Pack Installation | ||
| Care Pack services provide
a range of life cycle support options that let you choose the service levels
that meet your business requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including:
NOTE: For more
information on HP Care Pack services, contact any of our worldwide sales
offices, resellers or visit our worldwide website at: http://www.hp.com/hps/carepack
|
||
|
|
| Warranty Upgrade Options |
|
|
| HP Care Pack Information | For
additional HP Care Pack (hardware & software) information, as well as orderable
part numbers, please refer to the URL listed below: http://h18005.www1.hp.com/services/carepaq/index.html | |
|
|
Related Options
| UPS Options | Extended Runtime Module (ERM),
R/T2200 |
AF412A
|
| Service & Support (Care Pack) | Hardware Installation (Electronic) |
U4690E
|
|
|
Technical Specifications
| UPS T1000 G2 Specifications | ||
| Low-Voltage
Model T1000 G2 AF403A |
Unit Dimensions (WxHxD) |
10.25 x 6.75 x 14 (inch) 260.35 x 171.45 x 355.6 (mm) |
| Shipping Dimensions | 17.44 x 11.31 x 14.50 (inch) 442.98 x 287.27 x 368.3 (mm) |
|
| Unit Weight | 36 lbs (16.33kg) | |
| Shipping Weight | 41 lbs (18.60 kg) | |
| Operating Voltage Settings | 120V | |
| Power Out (VA/Watts) | 1000/650 | |
| Input Connection | 5-15P (attached cord) | |
| Output Connection | (8) 5-15R | |
| Load Segments | 1 | |
| NOTE: Part Number AF403A is user selectable for 100V, 110V, or 120V via dip switch setting on the back of the unit | ||
|
|
||
| UPS T1500 G2 Specifications | ||
| Low-Voltage
Model T1500 G2 AF406A |
Unit Dimensions (WxHxD) |
10.25 x 6.75 x 14 (inch) 260.35 x 171.45 x 355.6 (mm) |
| Shipping Dimensions | 17.44 x 11.31 x 14.50 (inch) 442.98 x 287.27 x 368.3 (mm) |
|
| Unit Weight | 45 lbs (20.41kg) | |
| Shipping Weight | 50 lbs (22.68 kg) | |
| Operating Voltage Settings |
120V | |
| Power Out (VA/Watts) |
1500/900 | |
| Input Connection |
Attached 6' power cord with NEMA 5-15P | |
| Output Connection |
(8) 5-15R | |
| Load Segments | 1 | |
| NOTE: Part Number AF406A is user selectable for 100V, 110V, or 120V via dip switch setting on the back of the unit. | ||
|
|
||
| UPS R/T2200 G2 Specifications | ||
| Low-Voltage
Model R/T2200 G2 AF409A |
Unit Dimensions (WxHxD) |
3.5 x 17.5 x 19 inches (88.9 x 444.5 x 482.6 mm) |
| Shipping Dimensions |
23.50 x 19.63 x 13.13 inches (596.9 x 498.60 x 333.50 mm) |
|
| Unit Weight |
62 lbs (21.12 kg) | |
| Shipping Weight |
77 lbs (33.92 kg) | |
| Operating Voltage Settings | 120V | |
| Power Out (VA/Watts) |
2200/1600 | |
| Input Connection |
Attached 10' power cord with NEMA 5-20P | |
| Output Connection |
(4) 5-15R (4) 5-15/20R | |
| Load Segments | 4 | |
| NOTE: Part Number AF409A is user selectable for 100V, 110V, or 120V via dip switch setting on the back of the unit. | ||
|
|
||
| HP UPS T1000, T1500, and R/T2200 G2 Models Specifications | ||
| Electrical Input | Voltage Range |
100V, 120V, 208V, and 230V models |
| Frequency |
See Model Specifications for nominal and user selectable voltage settings | |
| Connections |
50/60 Hz | |
| Online Efficiency |
See Model Selection Matrix 95% |
|
| Surge Suppression | High Energy 6500A peak | |
| Electrical Output | Online Regulation |
-30% to +20% of nominal voltage |
| On battery Regulation |
±5% of nominal voltage | |
| Voltage Wave Form |
Sine wave | |
| Connections |
See Model Specifications | |
| Output Protection | Re-settable circuit protectors (T1500 and R/T2200 models only) | |
| Battery | Type |
Maintenance-free, sealed, valve-regulated lead acid (VRLA) |
| Recharge Time |
<4 hours to 90% usable capacity; <24 hours for complete recharge | |
| Battery String Voltage |
T1000 G2: 24V (2x12V) T1500 G2: 36V (3X12V) R/T2200 G2: 48V (4X12V) |
|
| Battery Ampere Hour (ah) | T1000 G2: 9ah T1500 G2: 9ah R/T2200 G2: 9ah |
|
| Communications | Serial Ports |
Standard communication port (ships with 6' Serial communication cable) |
| USB Port |
Standard communication port (ships with 6' USB communication cable) | |
| LED Indicators |
|
|
| Environmental and Safety | Operating Temperature |
50° to 104° F (10° to 40° C) |
| Transit and Storage Temperature |
-13° to 131° F (-25° to 55° C) | |
| Humidity (Operation) |
20% to 80% (non-condensing) | |
| Humidity (Non-operating) |
5% to 95% | |
| Operating Altitude |
Up to 6,600 ft (2000 m) above sea level | |
| Transit and Storage Altitude |
Up to 49,000 ft (15,000 m) above sea level | |
| Audible Noise | Less than 53 dBA max | |
| Safety Markings | Please see table below | |
| EMC Markings | Please see table below | |
| Emissions |
FCC CFR 47, Part 15 Class A, EN50091-2 | |
| Immunity |
IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-5 | |
| Surge Suppression | Conforms to IEEE 587B and ANSI C62.41 | |
|
|
||
| Safety Markings |
![]() |
|
|
| EMC Markings |
![]() |
|
|
| Estimated Backup Times Chart (In Minutes) | |||||
| T1000 G2 | ||
|
Load, percent
|
Load, Watts
|
Estimated battery runtime at 100% battery charge
|
|
20%
|
130
|
45 minutes
|
|
50%
|
325
|
15 minutes
|
|
80%
|
520
|
6 minutes
|
|
100%
|
650
|
4 minutes
|
| T1500 G2 | ||
|
Load, percent
|
Load, Watts
|
Estimated battery runtime at 100% battery charge
|
|
20%
|
210
|
45 minutes
|
|
50%
|
525
|
15 minutes
|
|
80%
|
840
|
6 minutes
|
|
100%
|
1050
|
4 minutes
|
| R/T2200G2 | |||
|
Load, percent
|
Load, Watts
|
Estimated battery runtime at 100% battery charge
|
Runtime with an ERM
|
|
20%
|
320
|
45 minutes
|
150 minutes
|
|
50%
|
800
|
15 minutes
|
60 minutes
|
|
80%
|
1280
|
8.5 minutes
|
30 minutes
|
|
100%
|
1600
|
6 minutes
|
20 minutes
|
| NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions. | |||||||
|
|
|
Environment-friendly Products and Approach |
End-of-life Management and Recycling | Hewlett-Packard offers end-of-life HP product
return, trade-in, and recycling programs in many geographic areas. For trade-in
information, please go to http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will be
recycled, recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
|
|
||
|
© Copyright 2007 Hewlett-Packard Development Company, L.P. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. Unix is a registered trademark of The Open Group. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |