Overview
|
HP ProLiant DL140 Generation 3 (G3) | |||
![]() | ![]() | ||
Hot
Plug SAS/SATA Models | |||
| Front View: | Rear View: | ||
| 1. | Access panel | 1. | Two GbE LAN ports for NIC 1 and NIC 2 (RJ-45) |
| 2. | Two Non-Hot Plug SATA 3.5" Hard Drive Bays or Two Hot Plug SAS/SATA 3.5" Hard Drive | 2. | Low-Profile PCI Express x8/PCI-X riser board slot cover |
| 3. | Rear USB ports | ||
| 3. | Optional CD- or DVD-ROM drive | 4. | Video Port |
| 4. | System LEDs | 5. | Serial Port |
| 5. | USB Port | 6. | PS/2 Keyboard Port |
| 6. | Power on/off | 7. | PS/2 Mouse Port |
| 7. |
System Fans | 8. | LO100i 10/100 Mbps LAN port for IPMI management (RJ-45) |
| 8. |
Quad-Core and Dual-Core Intel® Xeon® Processors (Supports
up to Two) | 9. | Standard height/full-height PCI Express x16/PCI-X riser board |
| 10. | Power Supply Cable Socket | ||
| 9. | PC2-5300 Fully Buffered DIMMs (DDR2-667) memory slots | ||
| 10. | Expansion
Slots: Non-Hot Plug Models - Two available PCI-Express slots Hot-Plug Models - One available PCI-Express slot | ||
| 11. | Power Supply (650 Watts) | ||
| 12. | SAS/SATA Hot Plug Backplane (Hot Plug SAS/SATA Model) | ||
| What's New |
|
|
|
| At A Glance |
|
|
|
Standard Features
| NOTE:
For a brief, printer friendly data sheet that describes this product
and informs you of the essential capabilities and specifications, please
visit: http://h71028.www7.hp.com/ERC/downloads/4AA0-6065ENW.pdf NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - Factory Integrated Models" section. |
|
| Processor One of the following depending on Model |
Quad-Core Intel® Xeon®
processor X5365 (3.0 GHz, 120 W, 1333MHz Front Side Bus FSB) NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
| Quad-Core Intel® Xeon®
processor X5355 (2.66 GHz, 120 W, 1333MHz Front Side Bus FSB) NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Quad-Core Intel® Xeon® processor E5345 (2.33 GHz, 80 W, 1333MHz FSB) | |
| Quad-Core Intel® Xeon®
processor E5335 (2.00 GHz, 80 W, 1333MHz FSB) NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Quad-Core Intel® Xeon®
processor L5335 (2.00 GHz, 50 W, 1333MHz FSB, Low Voltage) NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Quad-Core Intel® Xeon®
processor L5320(1.86GHz, 50W, 1066MHz FSB, Low Voltage) NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Quad-Core Intel® Xeon®
processor E5320 (1.86 GHz, 80 W, 1066MHz FSB) NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Quad-Core Intel® Xeon® processor E5310 (1.60 GHz, 80 W, 1066MHz FSB) | |
| Dual-Core Intel® Xeon® processor 5160 (3.00 GHz, 80 W, 1333MHz FSB) | |
| Dual-Core Intel® Xeon®
processor 5150 (2.66 GHz, 65 W, 1333MHz FSB) NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Dual-Core Intel® Xeon®
processor 5148 (2.33 GHz, 40 W, 1333MHz FSB, Low Voltage) NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Dual-Core Intel® Xeon® processor 5140 (2.33 GHz, 65 W, 1333MHz FSB) | |
| Dual-Core Intel® Xeon®
processor 5130 (2.0 GHz, 65 W, 1333MHz FSB) NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Dual-Core Intel® Xeon® processor 5110 (1.60 GHz, 65 W, 1066MHz FSB) | |
|
|
|
| Upgradeability |
Upgradeable to two processors |
| Upgradeable to Xeon® Series 5300 Quad-Core, or 5100 Dual-Core processors (Please contact your regional sales support to determine quad core upgradeability. Some of the earlier shipping models may not support this upgrade) | |
|
|
|
| Chipset | Intel® 5000X Chipset |
|
|
|
| Cache Memory | 8MB (2 x 4MB) Level 2 cache
(5300 sequence) 4MB (1 x 4MB) Level 2 cache (5100 sequence) |
|
|
|
| Memory Protection | Memory mirroring with Advanced ECC capabilities |
|
|
|
| Memory | Type | PC2-5300 Fully Buffered DIMMs (DDR2-667) | |
| Standard | 1 GB | (2 x 512 MB) | |
| Maximum | 32 GB | (8 x 4 GB) | |
|
|
|||
| Network Controller | Two embedded NC320i PCIe Gigabit Server Adapters |
|
| |
|
Expansion Slots #
|
Technology
|
Width
|
Connector Width
|
Bus Number*
|
Form Factor
|
Notes
|
|
1
|
PCI Express 2.0 |
X16
|
X16
|
1
|
Full length,
full height slot |
Standard-Reserved slot for Smart Array P400 Controller
|
|
1
|
PCI-X |
133/100MHz
|
N/A
|
5
|
Full length,
full height slot |
Options - 100MHz bus speed operates when 2 PCI-X cards
are populated
|
|
2 |
PCI Express 2.0 |
X4
|
X8
|
6
|
Low-profile slot
|
Recommended for XX Card
|
|
2
|
PCI-X |
133/100MHz
|
N/A
|
5
|
Low-profile slot
|
Options - 100 MHz bus speed operates when 2 PCI-X cards
are populated
|
| NOTE: All slots can accept universal keyed PCI cards | ||||||
| * Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number. | ||||||
| ** Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest Device ID by bus (starting with the lowest bus). | ||||||
| *** PCI-X bus speed will be 133MHz when only one PCI-X card is installed. It will be 100MHz when both slots have PCI-X cards installed. | ||||||
|
|
||||||
| Storage Controller | Non-Hot Plug SATA Models | HP Embedded SATA RAID Controller (integrated into the south-bridge) supporting SW RAID 0,1 |
| Hot Plug SAS/SATA Models | HP 8 Internal Port SAS HBA with RAID 0,1 | |
| NOTE: A diskette drive is needed to install storage controller drivers during a Windows operating system installation from a CD. | ||
|
|
||
| Storage | Optical Drives: | |
| DVD-ROM | 8x IDE (ATAPI) DVD-ROM drive, slim (optional) | |
| CD-ROM | 24x IDE (ATAPI) CD-ROM drive (optional) | |
| DVD RW | 8x IDE (ATAPI) DVD-ROM drive, slim (optional) | |
| DVD/CD RW | 24x IDE (ATAPI) CD-ROM drive (optional) | |
| Diskette Drives | Via USB only | |
| Drive Bays: | ||
| Non-Hot Plug SATA | Up to 2 non-hot plug SATA 3.5" drives | |
| Hot-Plug SAS/SATA | Up to 2 hot plug SAS/SATA 3.5" drives | |
|
|
||
| Maximum Internal Storage | Non-Hot Plug SATA | 1TB | 2 x 500GB |
| Hot Plug SATA | 1.5TB | 2 x 750GB | |
| Non-Hot Plug SAS | 600GB | 2 x 300GB | |
| Hot Plug SAS | 600GB | 2 x 300GB | |
|
|
|||
| Interfaces | Parallel | None |
| Network RJ-45 (Ethernet) | 2 10/100/1000 NIC ports (plus 1 dedicated for the HP ProLiant Lights Out 100i Remote Management) | |
| Serial | 1 | |
| Pointing Device (Mouse) | 1 | |
| Graphics | 1 | |
| Keyboard | 1 | |
| USB | 4 (two front, two rear) NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html. |
|
|
|
||
| Graphics | Integrated on the system board: 1280 x 1024 at 8bpp (bits per pixel) or 2^8 = 256 colors or 1024 x 768 at 16bpp (bits per pixel) or 2^16 = 65536 or 64k colors |
|
|
|
| Form Factor | Rack (1U), (1.75 in/4.45 cm) |
|
|
|
| Server Management Stand Alone Software Product and ProLiant Essentials | HP Systems Insight Manager | HP Systems Insight Manager (HP SIM) provides a unified, secure and extensible standards-based environment to centrally manage servers, storage and other infrastructure devices, (both HP and non-HP) across multiple operating system platforms. |
| Rapid Deployment Pack (RDP) | Rapid Deployment Pack (RDP) extends HP Systems Insight Manager with a complete deployment solution for select HP ProLiant 100 series servers. RDP provides a central location to configure server hardware, deploy Windows, Linux and VMware ESX operating environments and install HP ProLiant Support Pack drivers using images and scripted profiles. For more information, visit: http://www.hp.com/servers/rdp | |
| NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to: http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. | ||
| HP Lights-Out 100i Remote Management | HP Lights-Out 100i Remote Management delivers affordable, entry level remote management capabilities for HP ProLiant 100 Series servers with embedded LO100i. It allows customers or their service providers to remotely manage ProLiant 100 Series servers remotely over a LAN or the Internet and consists of the following:
| |
| NOTE: Flexible and volume quantity (AKA) license kits are available for both the Lights-Out 100i Select and Lights-Out 100 Advanced Pack licenses as well as Electronic License To Use (E-LTU). AKA Tracking licenses require a 100 unit minimum forecast at initial contract signing. For these additional part numbers, please refer to each software products' QuickSpecs at this link for more information: http://h18004.www1.hp.com/products/servers/management/remotemgmt.html. | ||
| | ||
| Core Infrastructure Management | Subscriber's Choice | Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides software and driver change notifications for ProLiant products. Sign up at: http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis. |
| ROMPaq software and latest drivers | The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options, available through ProLiant Support Packs or downloaded from software and drivers download pages website at: http://www.hp.com/go/support. | |
| | ||
| Industry Standard Compliance | ACPI V2.0 Compliant |
| PCI 2.2 Compliant | |
| PXE Support | |
| WOL Support | |
| Microsoft® Logo certifications | |
| IPMI 2.0 Compliant | |
|
|
|
| Manageability |
HP Lights-Out 100i Standard providing the following OS-independent remote control capabilities:
HP Lights-Out 100i Select Pack providing license key activated upgrades to the following:
HP Lights-Out 100i Advanced Pack providing license key activated upgrades to the following:
|
| | |
| Security | Power-on password |
| Setup password | |
|
|
|
| Server Power Cords | One Highline IEC Power cord ships standard (for connection to a Power Distribution Unit) |
| NOTE: Rack models
ship standard with an IEC cable. Localized cables included with geographic specific models in other world regions. |
|
|
|
|
| UPS and PDU Power Cord Matrix |
Please see the UPS and PDU cable
matrix that lists cable descriptions, requirements, and specifications for
UPS and PDU units: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf. |
|
|
|
| Power Supply | 650 Watts, auto-switching, PFC (Power Factor Correcting) |
|
| |
| System Fans | 6 system fans ship standard; Non-hot plug, Non-redundant |
| | |
| OS Support | Microsoft
Windows® 2000 Server (32-bit) Microsoft Windows 2000 Advanced Server (32-bit) Microsoft Windows 2003 and Microsoft Windows 2003/R2 Standard Edition (32-bit) Microsoft Windows 2003 and Microsoft Windows 2003/R2 Enterprise Edition (32-bit) Microsoft Windows 2003 and Microsoft Windows 2003/R2 Web Edition (32-bit) Microsoft Windows 2003 and Microsoft Windows 2003/R2 for Extended Systems Standard Edition (64-bit) Microsoft Windows 2003 and Microsoft Windows 2003/R2 for Extended Systems Enterprise Edition (64-bit) Microsoft Windows 2008 Red Hat Enterprise Linux SUSE Linux Enterprise Server | |
|
NOTE: For more complete and up-to-date information of all supported OSes
for ProLiants, certification information and how to buy server operating systems
from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html. NOTE: For an up-to-date listing of the latest software and drivers available for your server, please select your server: http://h20000.www2.hp.com/bizsupport/TechSupport/Product.jsp?lang=en&cc =us&taskId=135&prodTypeId=15351&prodCatId=241435. | ||
| | ||
| Rack Airflow Requirements | Rack
10000 series Cabinets The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment. Front
and rear doors: If your 42U server rack includes closing front and rear doors,
you must allow 5,350 sq cm (830 square inches) of hole evenly distributed from
top to bottom to permit adequate airflow (equivalent to the required 64 percent
open area for ventilation). | |
| | ||
| Telco Rack Support | Telco Rack Kit:
Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions. http://www.racksolutions.com/hp |
|
|
|
||
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to: http://www.hp.com/go/factory-express. |
|
|
|
| HP Enterprise Configurator |
The HP eCo-Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. |
|
|
|
||
| Service and Support | HP Care Pack Services provide total care and support expertise with committed response designed to meet your IT and business needs. HP Care Pack services include coverage for the HP branded hardware options qualified for the server that are purchased at the same time or afterward and internal to the enclosure. It also includes the 22" and smaller external monitors and tower UPS options up to 3kVA. These items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included and standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. To fully capitalize on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime. Recommended Service - Simplify ProLiant solution implementation, maintenance and management.
Enhanced Service - Optimize service level to increase IT performance and availability
Installation
& Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer
Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F,
excl. HP holidays. For a complete listing of service offerings and
information visit: |
|
|
HPC Interconnects
| NOTE: High Performance Computing (HPC) interconnect technologies are available for the DL140 under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects: http://www.hp.com/techservers/clusters/ucp/index.html |
| |
| HPC Interconnect | InfiniBand | PCI-X and PCI-Express adapters |
| Gigabit Ethernet | Use embedded ports | |
| Myrinet XP | PCI-X Rev D, Rev E and Rev F adapters |
|
|
Models
| Non Hot Plug Serial ATA (SATA) Models | ||
|
HP DL140G3 E5345 417748-xx1 HP DL140G3 E5310 HP
DL140G3 5160 HP DL140G3 5140 HP
DL140G3 5110 | Processor(s) One of the following depending on model | (1) Quad-Core Intel® Xeon®
processor E5345 (2.33 GHz, 80 W, 1333 MHz FSB) (1) Quad-Core Intel® Xeon® processor E5310 (1.60 GHz, 80 W, 1066 MHz FSB) (1) Dual-Core Intel® Xeon® processor 5160 (3.00 GHz, 80 W, 1333 MHz FSB) (1) Dual-Core Intel® Xeon® processor 5140 (2.33 GHz, 65 W, 1333 MHz FSB) (1) Dual-Core Intel® Xeon® processor 5110 (1.60 GHz, 65 W, 1066 MHz FSB) |
| Cache Memory | 8 MB (2 x 4 MB) Level
2 cache (5300 sequence) 4 MB (1 x 4 MB) Level 2 cache (5100 sequence) | |
| Memory | 1 GB (2 x 512 MB) PC2-5300 DDR2 Fully Buffered DIMMs (667MHz) with Advanced ECC capabilities | |
| Network Controller | Two embedded NC320i PCIe Gigabit Server Adapters | |
| Storage Controller | HP Embedded SATA RAID Controller | |
| Hard Drive | 80 GB NHP SATA HDD | |
| Internal Storage | 1TB maximum (2 x 500GB Non-Hot plug 3.5" SATA hard drives) | |
| Optical Drive | Optional CD-ROM, DVD-ROM, DVD RW, DVD/CD RW | |
| Form Factor | Rack (1U) | |
| | ||
| Hot Plug Serial ATA (SATA)/Serial Attached SCSI (SAS) Models | ||
|
HP DL140G3 E5345 HP DL140G3 E5310 HP
DL140G3 5160 HP DL140G3 5140 HP
DL140G3 5110 | Processor(s) One of the following depending on model | (1) Quad-Core Intel® Xeon®
processor E5345 (2.33 GHz, 80 W, 1333 MHz FSB) (1) Quad-Core Intel® Xeon® processor E5310 (1.60 GHz, 80 W, 1066 MHz FSB) (1) Dual-Core Intel® Xeon® processor 5160 (3.00 GHz, 80 W, 1333 MHz FSB) (1) Dual-Core Intel® Xeon® processor 5140 (2.33 GHz, 65 W, 1333 MHz FSB) (1) Dual-Core Intel® Xeon® processor 5110 (1.60 GHz, 65 W, 1066 MHz FSB) |
| Cache Memory | 8 MB (2 x 4 MB) Level
2 cache (5300 sequence) 4 MB (1 x 4 MB) Level 2 cache (5100 sequence) | |
| Memory | 1 GB (2 x 512 MB) PC2-5300 DDR2 Fully Buffered DIMMs (667MHz) with Advanced ECC capabilities | |
| Network Controller | Two embedded NC320i PCIe Gigabit Server Adapters | |
| Storage Controller | HP 8 Internal Port SAS HBA with RAID | |
| Hard Drive | None ship standard (up to 2 Hot Plug SATA or SAS drives supported) | |
| Internal Storage | 1.5TB max. (2 x 750GB Hot Plug 3.5" SATA hard drives) or 600GB (2 x 300 GB Hot Plug 3.5" SAS hard drives) | |
| Optical Drive | Optional CD-ROM, DVD-ROM, DVD RW, DVD/CD RW | |
| Form Factor | Rack (1U) | |
| Availability | Hot Plug Hard Drives | |
|
| ||
| Country Code
Key |
XX=00 | U.S. |
| XX=29 | Japan | |
| XX=37 | APD | |
| XX=42 | Euro | |
| XX=AA | CN |
|
|
Configuration Information - Factory Integrated Models
| NOTE:
This section lists some of the steps required to configure a Factory Integrated
Model. To ensure only valid configurations are ordered, HP recommends the use
of an HP approved configurator. Contact your local sales representative for information
on CTO product offerings and requirements. NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis. NOTE: This product offering does not support HP Factory Express Server Configuration Level 1. NOTE: FIO indicates that this option is a Factory Installable Option. | ||
| Step 1: Base Configuration (choose one of the following configurable models) | ||
| Non-Hot Plug Model | ||
| HP ProLiant DL140 G3 Non- Hot Plug SATA Rack CTO Chassis (North America) |
409023-B21 | |
| Factory Integrated Model ships with: | ||
| Two integrated Broadcom 10/100/1000 NICs (Wake on LAN and PXE capable) | ||
|
Two available PCI-Express slots:
(NOTE: Optional PCI-X option kit includes: Slot 1: full-length/full-height PCI-X 100; Slot 2: low-profile/half-height PCI-X 100. PCI-X slots are 64 bits; 133 MHz capable if only one PCI-X card is installed in the server.) | ||
| HP Embedded SATA RAID Controller | ||
| 650 Watt Power Supply | ||
| One Highline IEC Power Cord | ||
| 6 Non-Hot Plug Fans | ||
| Rack (1U), (1.75 in / 4.45 cm) | ||
| HP ProLiant DL140 G3 Hot Plug SAS/SATA Rack CTO Chassis (North America) |
409024-B21 | |
| Factory Integrated Model ships with: | ||
| Two integrated Broadcom 10/100/1000 NICs (Wake on LAN and PXE capable) | ||
|
One available PCI-Express slot:
(NOTE: Optional PCI-X option kit includes: Slot 1: full-length/full-height PCI-X 100; and Slot 2: low-profile/half-height PCI-X 100. PCI-X slots are 64 bits; 133 MHz capable if only one PCI-X card is installed in the server) | ||
| One HP SAS/SATA Host Cable Kit | ||
| One Hot Plug Backplane Option Kit | ||
| 650 Watt Power Supply | ||
| One Highline IEC Power Cord | ||
| 6 Non-Hot Plug Fans | ||
| Rack (1U), (1.75 in / 4.45 cm) | ||
| | ||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processors | Quad-Core Intel® Xeon® processor X5365 (3.0 GHz, 120W, 1333MHz Front Side Bus, FSB) |
452997-L21 |
| Quad-Core Intel® Xeon® processor X5355 (2.66 GHz, 120 W, 1333 MHz FSB) FIO BASE | 409279-L21 | |
| Quad-Core Intel® Xeon® processor E5345 (2.33 GHz, 80 W, 1333 MHz FSB) FIO BASE |
409159-L21 | |
| Quad-Core Intel® Xeon® processor E5335 (2.00 GHz, 80 W, 1333 MHz FSB) FIO BASE | 442992-L21 | |
| Quad-Core Intel® Xeon® processor L5335 (2.00GHz, 50W, 1333 MHz FSB) FIO BASE |
453475-L21 | |
| Quad-Core Intel® Xeon® processor L5320 (1.86GHz, 50W, 1066 MHz FSB) FIO BASE |
442995-L21 | |
| Quad-Core Intel® Xeon® processor E5320 (1.86 GHz, 80 W, 1066 MHz FSB) FIO BASE |
409157-L21 | |
| Quad-Core Intel® Xeon® processor E5310 (1.60 GHz, 80 W, 1066 MHz FSB) FIO BASE |
409278-L21 | |
| Dual-Core Intel® Xeon® processor 5160 (3.00 GHz, 80 W, 1333 MHz FSB) FIO BASE |
417786-L21 | |
| Dual-Core Intel® Xeon® processor 5150 (2.66 GHz, 65 W, 1333 MHz FSB) FIO BASE |
417784-L21 | |
| Dual-Core Intel® Xeon® processor 5148 (2.33 GHz, 40 W, 1333 MHz FSB) FIO BASE |
433253-L21 | |
| Dual-Core Intel® Xeon® processor 5140 (2.33 GHz, 65 W, 1333 MHz FSB) FIO BASE |
417774-L21 | |
| Dual-Core Intel® Xeon® processor 5130 (2.0 GHz, 65 W, 1333 MHz FSB) FIO BASE |
417772-L21 | |
| Dual-Core Intel® Xeon® processor 5110 (1.60 GHz, 65 W, 1066 MHz FSB) FIO BASE |
417770-L21 | |
|
| ||
| Memory | 1 GB FBD PC2-5300 2X512 Kit | 397409-B21 |
| 2 GB FBD PC2-5300 2x1GB LP Kit | 461826-B21 | |
| 2 GB FBD PC2-5300 2X1GB Kit |
397411-B21 | |
| 4 GB FBD PC2-5300 2X2GB Kit | 397413-B21 | |
| 8 GB FBD PC2-5300 2X4GB Kit |
397415-B21 | |
|
| ||
| Hard Drive | Serial-ATA (SATA) Non-Hot Plug Hard Drives (To be used with Non-Hot Plug CTO Chassis Models Only) | |
| HP 80GB 1.5G SATA 7.2K NHP 3.5" HDD |
383410-B21 |
|
| HP 160GB 1.5G SATA 7.2K NHP 3.5" HDD |
411275-B21 |
|
| HP 250GB 1.5G SATA 7.2K NHP 3.5" HDD |
411276-B21 |
|
| HP 500GB 1.5G SATA 7.2K NHP 3.5" HDD, FIO* |
404469-B21 |
|
| *Factory Integrated Only | ||
| Serial-ATA (SATA) Hot Plug Hard Drives (To be used with SAS/SATA Hot Plug CTO Chassis Models Only) | ||
| HP 80GB SATA 7.2K Hot Plug 3.5" HDD |
349237-B21 |
|
| HP 160GB SATA 7.2K Hot Plug 3.5" HDD |
349238-B21 |
|
| HP 250GB SATA 7.2K Hot Plug 3.5" HDD |
349239-B21 |
|
| HP 500GB SATA 7.2K Hot Plug 3.5" HDD |
395473-B21 |
|
| HP 750GB SATA 7.2K Hot Plug 3.5" HDD |
432341-B21 |
|
| Serial-Attached SCSI (SAS)
Hot Plug Hard Drives (To be used with SAS/SATA Hot Plug CTO Chassis
Models Only) NOTE: A SAS HBA or Array Controller is required. |
||
| HP 72GB 3G SAS 15K 3.5" SP HDD |
375870-B21 |
|
| HP 146GB 3G SAS 15K 3.5" SP HDD |
375872-B21 |
|
| HP 300GB 3G SAS 15K 3.5" SP HDD |
431944-B21 |
|
|
|
||
| Storage Controllers | SAS HBA | |
| HP 8 Internal Port SAS HBA with
RAID NOTE: For use with Hot Plug SAS/SATA CTO Chassis models. Required only when upgrading from a non-hot plug to a hot-plug model. NOTE: The selection HP 8 Internal Port SAS HBA with RAID requires the purchase of the PCI-X Riser Option kit (P/N 409347-B21) |
347786-B21
|
|
| HP SC44Ge Host Bus Adapter NOTE: SAS HBA |
416096-B21
|
|
| SAS Controllers | ||
| HP Smart Array E200 Controller | ||
| HP Smart Array E200/128 BBWC Controller NOTE: Selection of the E500 with the E200 will prevent installation of the E500 battery-backed write cache module. |
411508-B21
|
|
| 128-MB BBWC (Battery-Backed Write Cache) Enabler |
351580-B21
|
|
| HP Smart Array E500 Controller | ||
| HP Smart Array E500/256MB Controller
(Standard RAID 0,1, 1+0) NOTE: Selection of the E500 with the E200 will prevent installation of the E500 battery-backed write cache module. |
435129-B21 | |
| 256MB Battery-backed write cache
upgrade for RAID 5 support NOTE: when installing a battery-backed write cache module, the HP Smart Array E500 must be installed in the full-length PCI slot |
383280-B21 | |
| SCSI Controller | ||
| HP Single Channel U320 SCSI Controller | 374654-B21 | |
| SCSI HBA | ||
| HP SC11Xe Host Bus Adapter NOTE: U320 HBA with tape support only. |
412911-B21 | |
|
|
||
| Step 3: Choose Additional Options for Factory Integration | ||||
| NOTE: For additional options, please refer to the "Options" section below. Some options may not be available for factory integration. Please contact an HP sales representative for additional information. |
|
|
Options
|
Server Management Stand Alone Software Product and ProLiant Essentials | NOTE: Electronic licensing options are available for Insight Control suites and select ProLiant Essentials software products. Please see the appropriate Insight Control and ProLiant Essentials QuickSpecs for additional information. | |
| Deploy | ||
| ProLiant Essentials Rapid Deployment Pack | ||
| ProLiant
Essentials Rapid Deployment Pack No Media 1-Server License including 1 year of
24x7 Technical Support and Updates NOTE: This license allows 1 server to be deployed and managed via RDP. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. |
452151-B21 | |
| NOTE: For additional ProLiant Essentials Rapid Deployment Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html | ||
| Control | ||
| Integrated Lights-Out 100i Select Pack and Advanced Pack | ||
| HP Lights Out 100i Select Pack 1-Server License |
413111-B21 | |
| HP Lights Out 100i Advanced Pack 1-Server License |
413115-B21 | |
| NOTE:
Flexible and volume quantity (AKA) license kits are available for both the
Lights-Out 100i Select and Lights-Out 100i Advanced Pack licenses as well as Electronic
License To Use (E-LTU). AKA Tracking licenses require a 100 unit minimum forecast
at initial contract signing. For these additional part numbers, please refer to
QuickSpecs at this link for more information: http://h18004.www1.hp.com/products/servers/management/remotemgmt.html NOTE: For additional ProLiant Integrated Light-Out Select Pack and Advanced Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12087_div/12087_div.html | ||
| NOTE: Flexible
and volume quantity license kits are available for ProLiant Essentials Value Packs.
Refer to: http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. | ||
| | ||
| Processor | Quad-Core Intel® Xeon® processor X5365 (3.0 GHz, 120W, 1333MHz FSB) |
452997-B21
|
| Quad-Core Intel® Xeon® processor X5355 (2.66 GHz, 120 W, 1333 MHz FSB) Option Kit |
409279-B21
|
|
| Quad-Core Intel® Xeon® processor E5345 (2.33 GHz, 80 W, 1333 MHz FSB) Option Kit |
409159-B21
|
|
| Quad-Core Intel® Xeon® processor E5335 (2.00 GHz, 80 W, 1333 MHz FSB) Option Kit |
442992-B21
|
|
| Quad-Core Intel® Xeon® processor L5335 (2.00GHz, 50W, 1333 MHz FSB, Low Voltage) Option Kit |
453475-B21
|
|
| Quad-Core Intel® Xeon® processor L5320 (1.86 GHz, 50W, 1066 FSB) Option Kit |
442995-B21
|
|
| Quad-Core Intel® Xeon® processor E5320 (1.86 GHz, 80 W, 1066 MHz FSB) Option Kit |
409157-B21
|
|
| Quad-Core Intel® Xeon® processor E5310 (1.60 GHz, 80 W, 1066 MHz FSB) Option Kit |
409278-B21
|
|
| Dual-Core Intel® Xeon® processor 5160 (3.00 GHz, 80 W, 1333 MHz FSB) Option Kit |
417786-B21
|
|
| Dual-Core Intel® Xeon® processor 5150 (2.66 GHz, 65 W, 1333 MHz FSB) Option Kit |
417784-B21
|
|
| Dual-Core Intel® Xeon® processor 5148 (2.33 GHz, 40 W, 1333 MHz FSB, Low Voltage) Option Kit |
433253-B21
|
|
| Dual-Core Intel® Xeon® processor 5140 (2.33 GHz, 65 W, 1333 MHz FSB) Option Kit |
417774-B21
|
|
| Dual-Core Intel® Xeon® processor 5130 (2.00 GHz, 65 W, 1333 MHz FSB) Option Kit |
417772-B21
|
|
| Dual-Core Intel® Xeon® processor 5110 (1.60 GHz, 65 W, 1066 MHz FSB) Option Kit |
417770-B21
|
|
|
|
||
|
Memory (FBDIMMs) | 1 GB FBD PC2-5300 2 X 512 Kit | 397409-B21 |
| 2 GB FBD PC2-5300 2 x 1 GB LP Kit | 461826-B21 | |
| 2 GB FBD PC2-5300 2 X 1 GB Kit | 397411-B21 | |
| 4 GB FBD PC2-5300 2 X 2 GB Kit | 397413-B21 | |
| 8 GB FBD PC2-5300 2 X 4 GB Kit |
397415-B21 | |
|
| ||
| Hard Drives | Serial-ATA (SATA) Non-Hot Plug Hard Drives (Non-Hot Plug Models Only) | |
| HP 80GB 1.5G SATA 7.2K NHP 3.5" HDD |
383410-B21 |
|
| HP 160GB 1.5G SATA 7.2K NHP 3.5" HDD |
411275-B21 |
|
| HP 250GB 1.5G SATA 7.2K NHP 3.5" HDD |
411276-B21 |
|
| NOTE: When purchasing systems with the 500GB Non-Hot Plug SATA drives, please reference the Configuration Information Section of this QuickSpecs to order via Configuration to Order. | ||
| Serial-ATA (SATA)
Hot Plug Hard Drives (SAS/SATA Hot Plug Models Only) NOTE: A SAS HBA or Array Controller is required. |
||
| HP 80GB SATA 7.2K Hot Plug 3.5" HDD |
349237-B21 |
|
| HP 160GB SATA 7.2K Hot Plug 3.5" HDD |
349238-B21 |
|
| HP 250GB SATA 7.2K Hot Plug 3.5" HDD |
349239-B21 |
|
| HP 500GB SATA 7.2K Hot Plug 3.5" HDD |
395473-B21 |
|
| HP 750GB SATA 7.2K Hot Plug 3.5" HDD |
432341-B21 |
|
| Serial-Attached SCSI (SAS) Hot Plug Hard Drives (SAS/SATA Hot Plug Models Only) | ||
| HP 72GB 3G SAS 15K 3.5" DP HDD |
384852-B21 |
|
| HP 72GB 3G SAS 15K 3.5" SP HDD |
375870-B21 |
|
| HP 146GB 3G SAS 15K 3.5" DP HDD |
384854-B21 |
|
| HP 146GB 3G SAS 15K 3.5" SP HDD |
375872-B21 |
|
| HP 300GB 3G SAS 15K 3.5" DP HDD |
416127-B21 |
|
| HP 300GB 3G SAS 15K 3.5" SP HDD |
431944-B21 |
|
| NOTE: The purchase of SAS HBA or array controller is required. | ||
|
|
||
| Graphic Cards | NVIDIA Quadro FX3500 256MB PCIe |
435681-B21 |
| NVIDIA Quadro FX1500 256MB PCIe |
435703-B21 |
|
| NOTE: Graphic cards are supported on Windows 2003 and Linux Operating Systems. | ||
|
|
||
| Optical Drives | DVD-ROM Drive (optional) |
361040-B21
|
| 24x CD-ROM Drive (optional) |
349046-B21
|
|
| DVD-RW Drive (optional) |
395498-B21
|
|
| DVD/CD RW Drive (optional) |
377402-B21
|
|
| Multibay II DVD/CD-RW Combo Drive
NOTE: When purchasing the Multibay II DVD/CD-RW Combo Drive, (P/N PA850A), the USB 2.0 Multibay II Cradle (P/N PA509A) is required. |
PA850A
|
|
| USB 2.0 MultiBay II Cradle, External NOTE: When purchasing the Multibay II DVD/CD-RW Combo Drive, (P/N 850A), the USB 2.0 Multibay II Cradle, (P/N PA509A) is required. |
PA509A
|
|
|
|
||
| Storage Controllers | SAS HBA | |
| HP 8 Internal Port SAS HBA with
RAID NOTE: For use with Hot Plug SAS/SATA models. Required only when upgrading from a non-hot plug to a hot plug model. NOTE: The selection HP 8 Internal Port SAS HBA with RAID requires the purchase of the PCI-X Riser Option kit (P/N 409347-B21) |
347786-B21
|
|
| HP SC44Ge Host Bus Adapter NOTE: SAS HBA. |
416096-B21
|
|
| SAS Controller | ||
| HP SAS/SATA Host Cable Kit NOTE: For use with Hot Plug SAS/SATA models. Required only when upgrading from a non-hot plug to a hot plug model. |
389650-B21
|
|
| HP Smart Array E200 Controller | ||
| HP Smart Array E200/128 BBWC Controller NOTE: Selection of the E500 with the E200 will prevent installation of the E500 battery-backed write cache module. |
411508-B21
|
|
| 128-MB BBWC (Battery-Backed Write Cache) Enabler |
351580-B21
|
|
| HP Smart Array E500 Controller | ||
| HP Smart Array E500/256MB Controller
(Standard RAID 0,1, 1+0) NOTE: Selection of the E500 with the E200 will prevent installation of the E500 battery-backed write cache module. |
435129-B21
|
|
| 256MB Battery-backed write cache
upgrade for RAID 5 support NOTE: when installing a battery-backed write cache module, the HP Smart Array E500 must be installed in the full-length PCI slot. |
383280-B21
|
|
| HP PCI-C Riser Board | ||
| HP PCI-X Riser Board Kit | 409347-B21 | |
| Hot Plug Backplane | ||
| Hot Plug Backplane Option Kit
NOTE: Required when upgrading from a non-hot plug to a hot plug model. |
||
| SCSI Controller | ||
| 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 | 374654-B21 | |
| SCSI HBA | ||
| HP SC11Xe Host Bus Adapter NOTE: U320 HBA with tape support only. |
412911-B21 | |
|
|
||
| Communications | HP NC110T PCI Express 1 Port Gigabit
Server Adapter NOTE: Does not support Windows 2000. |
434905-B21
|
| HP NC360T PCI Express Dual Port Gigabit Server Adapter |
412648-B21
|
|
| HP NC364T PCI Express Quad Port
Gigabit Server Adapter NOTE: Does not support Windows 2000. |
435508-B21
|
|
| HP NC373F PCI Express Multifunction Gigabit Server Adapter |
394793-B21
|
|
| HP NC373T PCI Express Multifunction Gigabit Server Adapter |
394791-B21
|
|
| HP NC380T PCI Express Dual Port
Multifunction Gigabit Server Adapter NOTE: Supported on a Full Length-Full Height slot only. |
394795-B21
|
|
| HP NC510C PCIe 10 Gigabit Server
Adapter NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510C adapter. |
414129-B21
|
|
| HP NC510F PCIe 10 Gigabit Server
Adapter NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510F adapter. |
414126-B21
|
|
|
|
||
| HPC Specific Options | InfiniBand 4X PCI-E Dual Port Host Adapter |
380298-B21 |
| InfiniBand 4X PCI-X Dual Port Host Adapter |
380299-B21
|
|
| HP IB 4X DDR PCI-e Dual Port 0 Memory HCA | 483513-B21 | |
| HP IB 4X DDR PCI-e DUAL PORT HCA |
448397-B21
|
|
| HP IB 4X DDR PCI-e Dual Port HCA |
409376-B21
|
|
| Myrinet PCI 2XP Rev-E 4MB Network Interface Card |
373983-B21
|
|
| Myrinet 2XP PCI-X, Fiber F-Series, 2MB NIC |
390456-B21
|
|
| NOTE: For HPC interconnect adapters please see the HPC Interconnect section of this QuickSpecs. | ||
|
|
||
| Rack Kits | 1U Cable Management Arm NOTE: Package contains two cable management arms |
365403-B21 |
|
|
||
| Tape Drives | USB Tape Drives | |
| HP StorageWorks 1U USB Rack-Mount Kit with one DAT 72 USB Tape Drive |
AG594A | |
| HP StorageWorks 1U USB Rack-Mount Kit with one DAT 160 USB Tape Drive |
AG703A | |
| Ultrium External Tape Drive | ||
| HP
StorageWorks Ultrium 232 Internal Tape Drive, (Carbonite) NOTE: HP recommends combining this tape drive with the 1U SCSI Rack-Mount kit (A7445B) for a complete rack-mount solution. |
DW064A | |
| Rack-Mount Tape Drive | ||
| HP
StorageWorks 1U SCSI Rack-Mount kit NOTE: The 1U Rack-Mount Kit can support up to (2) half-height tape drives and is compatible with multiple Single-Ended and LVD SCSI tape drives including the DAT 24, DAT 40, DAT 72, DLT VS80, DLT VS160, Ultrium 215, Ultrium 232, Ultrium 448 and Ultrium 920 tape drives. |
A7445B | |
| HP
StorageWorks 1U USB Rack-Mount Kit NOTE: The 1U USB Rack-Mount Kit can support up to (2) half-height tape drives and is compatible with the DAT 24 USB, DAT 40 USB and DAT 72 USB tape drives. |
A8007A | |
| NOTE:
When attaching to an external tape drive, autoloader or library, you must also
purchase a HBA NOTE: For a complete listing of HP tape drive offerings supported with the DL140 G3, visit: http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html | ||
| | ||
| HP D2D Backup System | HP StorageWorks
D2D110 Backup System NOTE: 1TB of Disk Storage. | EH880A |
| HP StorageWorks D2D110 Backup
System with Data Protector Express Software Kit NOTE: 1TB of Disk Storage. |
EH923A | |
| HP
StorageWorks D2D120 Backup System NOTE: 2TB of Disk Storage. |
EH884A | |
| HP
StorageWorks D2D120 Backup System with Data Protector Express Software Kit NOTE: 2TB of Disk Storage. |
EH924A | |
HP
StorageWorks D2D130 Backup System | EH950A | |
HP StorageWorks D2D130 Backup
System with Data Protector Express Software Kit | EH951A | |
HP StorageWorks D2D130 Backup
System with LTO-3 Ultrium 920 SAS Tape Drive | EH952A | |
| NOTE: Please
see the HP D2D Backup Systems QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/12651_div/12651_div.html (Worldwide) | ||
| | ||
| StorageWorks Options | StorageWorks Fibre Channel HBA | |
| NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows and Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html | ||
| HP StorageWorks 4 Gb PCI-X 2.0-to-Fibre Channel HBA | AB429A | |
| HP StorageWorks 4 Gb PCI-X 2.0 DC-to-Fibre Channel HBA | AE369A | |
| HP StorageWorks FC2142SR 4 Gb PCI-e HBA | A8002A | |
| HP StorageWorks FC2242SR Dual Channel 4 Gb PCI-e HBA | A8003A | |
| HP StorageWorks FC1142SR 4 Gb PCI-e HBA | AE311A | |
| HP StorageWorks FC1242SR Dual Channel 4 Gb PCI-e HBA | AE312A | |
| HP StorageWorks FC2143 4Gb PCI-X 2.0 HBA | AD167A | |
| HP StorageWorks 81Q PCI-e FC HBA | AK344A | |
| StorageWorks SCSI HBA | ||
| HP U320e SCSI Host Bus Adapter NOTE: Recommended Dual Channel Ultra320 SCSI Controller for connecting multi-drive MSL tape libraries to ProLiant servers |
AH627A | |
| HP StorageWorks FC2243 4Gb PCI-X 2.0 DC HBA | AD168A | |
| StorageWorks Connection Kit | ||
| HP StorageWorks 8Gb Simple SAN Connection Kit | AK241A | |
| StorageWorks Fibre Channel Switch | ||
| HP StorageWorks 8/20q Fibre Channel Switch | AK242A | |
|
|
||
| USB Options | HP 1GB USB 2.0 Floppy Drive Key | 442085-B21 |
| HP 256MB USB 2.0 Floppy Drive Key | 442084-B21 | |
| USB 1.44-MB External Diskette Drive | DC141B | |
| USB Floppy Drive | DC361B | |
| HP USB-P/S2 Mouse | DC369A | |
| HP Keyboard (USB) standard 2004 | DT528A#xxx | |
| USB 2.0 4-port HUB | DG954A | |
|
|
||
| HP KVM Switch Options | 2x1x16 IP Console Switch with Virtual Media | AF601A |
| 4x1x16 IP Console Switch with Virtual Media | AF602A | |
| 2x16 Server Console Switch with Virtual Media | AF600A | |
| PS/2 Virtual Media Interface
Adapter, 1 pack NOTE: Requires PS/2 and one USB port on server. | AF604A | |
| HP Server Console Switch (KVM), 0 x 1 x 8 port | 336044-B21 | |
| HP Server Console Switch (KVM), 0 x 2 x 16 port | 336045-B21 | |
| PS/2 Interface Adapter, 1 pack | 262588-B21 | |
| PS/2 Interface Adapter, 8 pack | 262587-B21 | |
| USB Interface Adapter, 1 pack | 336047-B21 | |
| Serial Interface Adapter - 1 pack with power supply | 373035-B21 | |
| HP 1x4 Console Switch | AF611A | |
| HP PS2 Server Console Cable, 6 foot, 2-Pack | AF612A | |
| HP USB Server Console Cable,
6 foot, 2-Pack NOTE: required for supporting USB peripherals. | AF613A | |
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm | ||
|
| ||
| HP Serial Console Server Options | HP 16 Port Serial Console Server (worldwide) | AF101A |
| HP 48 Port Serial Console Server (worldwide) | AF102A | |
| Serial Adapter, RJ45-D89 DCE Female, 1-pack | AF103A | |
| Serial Adapter, RJ45-D89 DCE Female, 8-pack | AF110A | |
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm | ||
| | ||
| Service and Support
Offerings (HP Care Pack Services)
|
Hardware Services 4-Hour On-site Service | |
| 13-Hour x 5-Day Coverage, 3 Years, Electronic |
U9509E |
|
| Hardware Services Next Business Day On-Site Service | ||
| 9-Hour x 5-Day Coverage, 3 Years, Electronic |
U9508E |
|
| Hardware Services 6-Hour Call to Repair On-Site Service | ||
| Hardware Installation, Electronic |
U9520E |
|
| NOTE: For more information, customer/resellers can contact http://www.hp.com/services/carepack |
|
|
Memory
| HP ProLiant DL140 G3 (all models) |
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
| Standard
Memory 1 GB (2 x 512 MB) PC2-5300 Fully Buffered DIMM memory, with Advanced ECC Capabilities Memory installed. Maximum Memory Up to 32GB memory is available with the optional installation of PC2-5300 Fully Buffered DIMM memory kits. NOTE: Memory should be installed in pairs and matched for optimum performance. |
| NOTE: Chart does not represent all possible memory configurations. |
| Memory |
Slot | |||||||
|
1 | 2 |
3 | 4 |
5 | 6 |
7 | 8 | |
| Standard (1 GB) |
512 MB | Empty |
512 MB | Empty |
Empty | Empty |
Empty | Empty |
| Maximum (32 GB) |
4 GB | 4
GB | 4 GB |
4 GB | 4
GB | 4 GB |
4 GB | 4
GB |
|
Following are memory options available from HP: | |
| 1 GB FBD PC2-5300 2 X 512 Kit |
397409-B21 |
| 2 GB FBD PC2-5300 2 x 1 GB LP Kit | 461826-B21 |
| 2 GB FBD PC2-5300 2 X 1 GB Kit | 397411-B21 |
| 4 GB FBD PC2-5300 2 X 2 GB Kit | 397413-B21 |
| 8 GB FBD PC2-5300 2 X 4 GB Kit | 397415-B21 |
|
|
Storage
|
|
1,2 | Two Non-hot plug SATA or Two 3.5" Hot Plug SAS/SATA Hard Drive Bays |
| 3 | Optional CD-ROM, DVD-ROM, DVD RW, DVD/CD RW | |
|
4 | Power On/Off |
| Drive Support | ||||
| | ||||
| Removable Media | ||||
|
Quantity Supported |
Position Supported |
Controller | ||
| IDE (ATAPI) CD-ROM Drive |
Up to 1 |
3 | Integrated IDE (ATAPI) (optional) | |
| DVD-ROM | Up
to 1 | 3 | Integrated IDE (ATAPI) (optional) | |
| DVD RW | Up
to 1 | 3
| Integrated IDE (ATAPI) (optional) | |
| DVD/CD RW |
Up to 1 |
3 | Integrated IDE (ATAPI) (optional) | |
|
| ||||
| Hard Drives | |||
| SATA - Non-Hot Plug | |||
Quantity Supported | Position
Supported | Controller | |
| 3.5-inch |
| ||
| 80 GB 7,200 rpm | Up
to 2 | 1;2
| HP Embedded SATA RAID Controller |
| 160 GB 7,200 rpm | Up
to 2 | 1;2
| HP Embedded SATA RAID Controller |
| 250 GB 7,200 rpm | Up
to 2 | 1;2
| HP Embedded SATA RAID Controller |
| 500 GB 7,200 rpm | Up
to 2 | 1;2
| HP Embedded SATA RAID Controller |
| SAS/SATA Hot Plug | |||
Quantity Supported | Position
Supported | Controller | |
| 3.5-inch | |||
| 80 GB SATA 7,200 rpm | Up
to 2 | 1;2
| HP Internal SAS HBA with RAID |
| 160 GB SATA 7,200 rpm | Up
to 2 | 1;2
| HP Internal SAS HBA with RAID |
| 250 GB SATA 7,200 rpm | Up
to 2 | 1;2
| HP Internal SAS HBA with RAID |
| 500 GB SATA 7,200 rpm | Up
to 2 | 1;2
| HP Internal SAS HBA with RAID |
| 750 GB SATA 7,200 rpm | Up
to 2 | 1;2
| HP Internal SAS HBA with RAID |
| 72 GB SAS 15,000 rpm | Up
to 2 | 1;2
| HP Internal SAS HBA with RAID |
| 146 GB SAS 15,000 rpm | Up
to 2 | 1;2
| HP Internal SAS HBA with RAID |
| 300 GB SAS 15,000 rpm | Up
to 2 | 1;2
| HP Internal SAS HBA with RAID |
| | |||
| Tape Drives and D2D Backup System | |||
|
NOTE: Installation of SCSI tape
drives in a ML110 G5 model requires SCSI controller kit (PN: 412911-B21). |
|
Position
Supported |
Controller
|
Controller/HBA Option Kit Part Number
|
|
| HP StorageWorks USB Tape DAT 72 USB DAT 160 USB 1U USB Rack-Mount Kit |
External
|
USB 2.0 Port
|
N/A
|
| HP StorageWorks SCSI Tape Ultrium 232 DAT 72 DAT 160 1U USB Rack-Mount Kit |
External
|
HP SC11Xe Host Bus Adapter
|
412911-B21
|
|
HP StorageWorks D2D Backup Systems |
External
|
Embedded Network Controller
|
N/A
|
|
|
Power Specifications
| 650W Power Supply Spare Kit | 416349-001 | |||||
| Operational Input Voltage Range (Vrms) | 90Vac to 264Vac full range | |||||
| Frequency Range (Nominal) (Hz) | 47 Hz to 63 Hz | |||||
| Nominal Input Voltage (Vrms) |
100
|
115
|
200
|
220
|
230
|
240
|
| Max Rated Output Wattage Rating |
653.10
|
653.19
|
653.08
|
652.96
|
653.08
|
652.96
|
| Nominal Input Current (A rms) |
8.55
|
7.31
|
4.12
|
3.77
|
3.6
|
3.46
|
| Max Rated Input Wattage Rating (Watts) |
855
|
840.72
|
824.12
|
827.5
|
806.3
|
805.71
|
| Max. Rated VA (Volt-Amp) |
990
|
990
|
990
|
990
|
990
|
990
|
| Efficiency (%) |
76.39
|
77.69
|
79.25
|
78.91
|
81
|
81.04
|
| Power Factor |
0.998
|
0.997
|
0.983
|
0.976
|
0.973
|
0.969
|
| Leakage Current (mA) |
<3.5mA
|
<3.5mA
|
<3.5mA
|
<3.5mA
|
<3.5mA
|
<3.5mA
|
| Maximum Inrush Current (A peak) |
60A
|
60A
|
60A
|
60A
|
60A
|
60A
|
| Maximum Inrush Current Duration (mS) |
1mS
|
1mS
|
1mS
|
1mS
|
1mS
|
1mS
|
|
|
System Specifications
| Power | ||
| ProLiant DL140 G3 Fully Configured |
115V/60Hz
|
220V/50Hz
|
| Fully Loaded System Input Wattage (W) |
651
|
638
|
| Fully Loaded System Input Current (A rms) |
5.7
|
3.0
|
| Fully Loaded System Thermal (BTU- Hr) |
2218
|
2174
|
| Fully Loaded System VA (Volt-Amp) |
657
|
657
|
| System Leakage with all power supplies loaded (mA) |
1.58
|
3.03
|
| System Inrush Current with all power supplies loaded (A) |
19
|
37
|
| Power cord requirements |
Nema 5-15P to IEC320-C13
|
IEC320-C13 to IEC320-C14
|
| NOTE: Power shown is for a fully configured system consisting of (2) CPU, (8) double-sided DIMMs, (2) HDDs, (1) CD-ROM, and (2) PCI cards. | ||
| Power Cord |
AF556A
|
|
|
|
Technical Specifications
| System Unit | Dimensions (HxWxD) (with feet) | 1.70 x 16.78 x 27.75 in (4.32 x 42.62 x 70.49 cm) | |
| Weight (approximate) | 35 lb (15.87 kg) | Fully configured (less rail kit) | |
| Input
Requirements (per power supply) | Range Input Voltage | 90 to 140 VAC/180 to 264 VAC | |
| Normal Line Voltage | 115 or 230 VAC | ||
| Line Frequency | 47 to 63 Hz | ||
| Rated Input Current load | 7.31A at 115VAC, 3.6A at 230VAC | ||
| BTU Rating | BTU-Hr | 2228 | |
| Power Supply Output Power (per power supply) | Rated Steady-State Power | 653W | |
| Maximum Peak Power | |||
| Temperature Range | Operating | 50° to 95° F (10° to 35° C) | |
| Shipping | -40° to 140° F (-40° to 60° C) | ||
| NOTE:
All temperature ratings shown are for sea level. An altitude derating of
1° C per 304.8 m (1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit is 3,048m (10,000 ft) or 70 Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3KPa/4.4 psia. System performance may be reduced if operating above 30° C. | |||
| Relative Humidity (non-condensing) | Operating | 10% to 85% | |
| Non-operating | 10% to 95% | ||
| Acoustic Noise | Idle (Fixed Disk Drives Spinning) | ||
| L WAd (BELS) | 6.96 | ||
| Operating (Random Seeks to Fixed Disks) | |||
| L WAd (BELS) | 7.0 | ||
| | |||
| Non-Hot Plug SATA Hard Drives | 80 GB 7.2K 383410-B21 |
Capacity | 80027 MB | |
| Height | 1.028 in (2.61 cm) | |||
| Width | 4.0 in (10.16 cm) | |||
| Interface | SATA 150 | |||
| Transfer Rate Synchronous (Maximum) |
150 MB/s | |||
| Seek Time (typical reads, including settling) |
Single Track | 0.8 ms | ||
| Average | 9.0 ms | |||
| Full-Stroke | 17.0 ms | |||
| Rotational Speed | 7,200 rpm | |||
| Physical Configuration | Bytes/Sector | 512 | ||
| Logical Blocks | 160,086,528 | |||
| Operating Temperature | 41° to 131° F (5° to 55° C) | |||
|
|
||||
| Two embedded NC320i PCIe Gigabit Server Adapters | Network Interface Compatibility | 10Base-T/100Base-TX/1000Base-TX | |
| IEEE 802.3 10Base-T | |||
| IEEE 802.3 1000Base-T | |||
| IEEE 802.3 100Base-TX | |||
| Data Transfer Method | 64-bit, 133MHz PCI(X)1.0 | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX
(Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000 Mb/s | ||
| Connector | RJ-45 | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP; up to 328 ft (100 m) | |
| 10/100/1000Base-TX | Category 5 UTP (2 Pair); up to 328 ft (100 m) | ||
|
| |||
| Environment-friendly Products and Approach | End-of-life Management and Recycling | Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. | |
| | |||
| © Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |