HP Integrity rx6600 System Overview
(Interior View)
|
|
|
| 1. |
Recessed Carrying Handles |
3. |
8 Hot Plug PCI-X 10 Slots (2 @ 266 MHz) |
| 2. |
Redundant Bulk Power |
4. |
Hot Swap Fans |
| HP Integrity rx6600 |
 |
| 1. |
7U Chassis |
3. |
4 Clamshell CPU Sockets |
| 2. |
16 SAS HDDs |
4. |
48 DDR2 DIMM Slots |
Standard Features
| Minimum
System |
- One 64-bit dual-core Intel Itanium 2 processor; either 1.6-GHz/24
MB cache, or 1.6 GHz/18 MB cache, or 1.4 GHz/12 MB cache; or 1.6 GHz/24
MB 9150N processor, or 1.6 GHz/18 MB 9140N processor, or 1.4 GHz/12
MB 9120N processor
- One I/O backplane. Either PCI-X 2.0 backplane with 8 available slots
or PCI-Express backplane with 8 available slots
- 2-GB PC2 4200 ECC×4 Single Rank Registered DDR2 SDRAMs (4×512MB
DIMMs)
- 24 DIMM slots (1×24 DIMM slot memory carrier board)
- One hot swap power supply
|
|
| Maximum
Server Capacities | - Four
dual core 64 bit Intel Itanium 2 processors; either 1.6 GHz/24 MB cache, or 1.6
GHz/18 MB cache, or 1.4 GHz/12 MB cache; or 1.6 GHz/24 MB 9150N processor, or
1.6 GHz/18 MB 9140N processor, or 1.4 GHz/12 MB 9120N processor
- One I/O
backplane. Either PCI-X 2.0 backplane with 8 available slots or PCI-Express backplane
with 8 available slots
- 384 GB PC2 4200 ECC×4 Single Rank Registered
DDR2 SDRAMs (24×8 GB DIMMs)
- 48 DIMM slots (2×24 DIMM slot
memory carrier boards)
- Sixteen Serial Attached SCSI (SAS) disk drives
- Two
hot swap power supplies (two supplies enables redundancy)
|
|
| Standard
System Features | - Operating
System support: HP UX 11i version 2 June 2006 Update, HP UX 11i v3, Linux RHEL
AS 4 U4 and SLES 10, OpenVMS V8.3 or higher for Integrity Servers and Microsoft
Windows Server 2008 for Itanium-based Systems, and Microsoft SQL Server 2005 and
SQL Server 2008
- Choice of core storage card.
For HP-UX and OpenVMS-based
systems: Must select one of two choices: PCI-X 8 port Serial Attached SCSI
(SAS) host bus adapter or PCI-Express 8-port Smart Array (P400) Serial Attached
SCSI Controller: 1. The PCI-X 8-port Serial Attached SCSI (SAS) host
bus adapter: Card will be installed in reserved core PCI-X I/O slot #1. This card
supports up to two internal RAID 1 volumes (2×2 HDDs) and a disk for global
hot spare, for a maximum of five disks in RAIDed arrays for HP UX and OpenVMS.
The additional three drives (of the maximum of eight drives supported) can be
accessed normally, but not configured for RAID. Factory set up of RAID 1 configurations
is supported. When a second SAS Controller is required to support disks 9 through
16, it cannot be factory configured for RAID (unless it is done through Factory
Express). For customer/field configured RAID arrays, the same limitations (two
RAID 1 arrays and one global hotspare) exist. The additional three HDDs (14 through
16) can be accessed normally, but not configured for RAID. Please see rx6600 Ordering
Guide for factory configuration details. - NOTE:
MirrorDisk/UX is available for SW Mirroring on all HDDs in HP UX based systems
and HP Volume Shadowing (software Raid 1) for HDDs in OpenVMS-based systems.
2. PCI-Express 8-port Smart Array (P400) Serial Attached SCSI Controller:
Requires PCI-Express Backplane (AD296A Option Code 300); card will be installed
in public slot #3, leaving 3 available PCI-Express slots and 4 available PCI-X
slots. This card supports internal RAID-1, 5 and 6 configurations. RAID-1 requires
a minimum of two identical HDDs, RAID-5 requires a minimum of three identical
HDDs, and RAID-6 requires a minimum of four identical HDDs. When a second core
PCI-Express P400 RAID controller is required to support disks 9 through 16, it
will be installed in slot #4, leaving two available PCI-Express slots and four
available PCI-X slots. Second core controller cannot be factory configured for
RAID (unless it is done through Factory Express). Please see rx6600 Ordering Guide
for factory configuration details. - NOTE:
PCIe Generation 2 cards are NOT supported in slots 3 and 4 of the AD296A Option
300 PCIe I/O Backplane.
For Windows and Linux based systems: Must
select one of three choices: PCI-X 8 port Smart Array (P600) Serial Attached SCSI
(SAS) controller, or PCI-Express 8-port Smart Array (P400) Serial Attached SCSI
Controller, or PCI-Express 16-port Smart Array (P800) Serial Attached SCSI Controller.
1. PCI-X 8-port Smart Array (P600) Serial Attached SCSI (SAS) controller:
Card will be installed in reserved core PCI-X I/O slot #1. Supports internal
RAID 1, 5 and 6 configurations. RAID 1 requires two identical HDDs, RAID 5 requires
three identical HDDs, and RAID 6 requires four identical HDDs. Factory set
up of RAID 1, 5 and 6 configurations with Smart Array SAS controller is also supported.
When a second SAS Controller is required to support disks 9 through 16, it cannot
be factory configured for RAID (unless it is done through Factory Express) . For
customer/field configured RAID arrays, all eight HDDs (9 through 16) can be configured
for RAID levels 1, 5 and 6 in any combination. Please see rx6600 Ordering Guide
for details. 2. PCI-Express 8-port Smart Array (P400) Serial Attached
SCSI (SAS) controller. Requires PCI-Express Backplane (AD296A Option Code
300); card will be installed in public slot #3, leaving 3 available PCI-Express
slots and 4 available PCI-X slots. This card supports internal RAID-1, 5 and 6
configurations. RAID-1 requires a minimum of two identical HDDs, RAID-5 requires
a minimum of three identical HDDs, and RAID-6 requires a minimum of four identical
HDDs. When a second core PCI-Express P400 RAID controller is required to support
disks 9 through 16, it will be installed in slot #4, leaving two available PCI-Express
slots and four available PCI-X slots. Second core controller cannot be factory
configured for RAID (unless it is done throughFactory Express). Please see rx6600
Ordering Guide for factory configuration details. 3. PCI-Express 16-port
Smart Array (P800) Serial Attached SCSI (SAS) controller: Requires PCI-Express
Backplane (AD296A Option Code 200); card will be installed in public slot #3,
leaving 3 available PCI-Express slots and 4 available PCI-X slots. This card supports
internal and external RAID-1, 5 and 6 configurations. RAID-1 requires a minimum
of two identical HDDs, RAID-5 requires a minimum of three identical HDDs, and
RAID-6 requires a minimum of four identical HDDs. When a second core PCI-Express
P800 RAID controller is required to support disks 9 through 16, it will be installed
in slot #4, leaving two available PCI-Express slots and four available PCI-X slots.
Second core controller cannot be factory configured for RAID (unless it is done
through Factory Express). Please see rx6600 Ordering Guide for factory configuration
details. - NOTE: PCIe Generation 2 cards
are NOT supported in slots 3 and 4 of the AD296A Option 300 PCIe I/O Backplane
(Legacy).
- Core PCI-X dual port 10/100/1000Base TX LAN (with auto speed
sensing; RJ 45 connector, Wake On LAN support)
- Integrated iLO2 Management
Processor for remote management and HA monitoring
- Telnet and web console
via 10/100Base TX management LAN (RJ 45 connector)
- Two RS 232 serial
ports, one for console from the integrated management processor and one from the
processor dependent hardware bus (PDH)
- Factory integration of processors,
memory, disk drives, removable media, I/O cards, and HP Universal 10000 G2 series
racks.
- Rackmountable into 19 inch cabinets-HP Universal 10000 G2 series
as well as many third party racks, including field integration into existing HP
System E racks
- Optional stand alone pedestal mount, field installation
only.
- Three year warranty with next business day on site.
|
|
| High
Availability | - N+1 Hot
swap cooling
- One Hot swap power supply-optional second power supply for
N+1 protection
- Hot Plug PCI X I/O slots (Note: Some I/O cards do not
support hot plugging. Please see Supported I/O card Table 3 this chapter for details.)
-
On line memory page deallocation
- ECC protected DDR2 memory
- Memory
double chip spare to overcome single DRAM chip failures
- Dynamic Processor
resilience and deallocation
- UPS power management
- Hot Plug internal
disks
- Internal RAID support. See Standard Systems Features on previous
page and rx6600 Ordering Guide for various levels of RAID support.
- Journal
file system with HP UX
- Auto reboot
- HP Serviceguard for HP UX
-
HP Serviceguard Extension for RAC for HP UX
- HP Serviceguard Extension
for SAP for HP UX
- Serviceguard Manager for HP UX and Linux Clusters
-
HP Event Monitoring Service
- HA Monitors for HP UX
- HA Toolkits
for HP UX and Linux
- HP Mirrordisk/UX
- Extended Campus Cluster,
HP Metrocluster, and HP Continentalclusters for HP UX
- HP OpenVMS clusters
-
HP Volume Shadowing for OpenVMS
- HP RMS Journaling for OpenVMS
-
HP System Insight Manager (SIM) for proactive fault management
- Microsoft
Windows Server 2008 for Itanium-based Systems, and Microsoft SQL Server 2005 and
SQL Server 2008
- HP StorageWorks Software for HP Integrity Servers running
Windows Server 2003 Enterprise Edition. Includes Cluster Extension XP and EVA,
Continuous Access, Business Copy and SQL Server Fast Recovery
- HP StorageWorks
Cluster Extension XP for Linux
|
|
| Security |
- Separate LAN for system management
- Password protection on console port
- Disablement of remote console ports
- SSL encryption on web console
|
|
Manageability - Deploy
|
- HP Ignite UX for installation and deployment of the operating system
- HP Software Distributor UX for software and patch management
- HP Integrity Essentials Foundation Pack for Linux
- HP Integrity Essentials Foundation Pack for Windows including Smart
Setup CD for easy server setup and configuration
|
Manageability - Monitor
|
- Built in Integrity iLO 2 Management Processor for comprehensive remote
server management of HP UX, Linux, Windows and OpenVMS
- HP Servicecontrol suite for HP UX servers including tools for system
administration, asset management, and fault management
- HP UX kernel configuration for easy, dynamic kernel parameter changes
- HP System Insight Manager (SIM)
|
| Manageability - Optimize |
- Process Resource Manager for HP UX resource management
- HP UX Workload Manager for HP UX workload management based upon service
level objectives
- HP OpenView GlancePlus Pack
- HP Intelligent Networking Pack for Windows
- HP Performance Management Pack for Windows
- Windows System Resource Manager (included with each copy of Windows
Server 2003 Enterprise Edition)
|
Configuration
| Processor
Configuration |
The HP Integrity rx6600 is a
symmetrical multiprocessing (SMP) server supporting up to four high performance
64 bit dual core Intel Itanium processors. The dual core Intel Itanium processor
supports hyper threading. Each core of the processor supports two threads. |
|
| Processor
Details | Dual core Intel
Itanium processors: - 1.6 GHz with 24 MB Level 3 Cache, 12 MB per core
processor (Upgrade Only)
- 1.6 GHz with 24 MB Level 3 Cache, 12 MB per core
9150N processor
- 1.6 GHz with 18 MB Level 3 Cache, 9 MB per core processor
(Upgrade Only)
- 1.6 GHz with 18 MB Level 3 Cache, 9 MB per core 9140N processor
- 1.4
GHz with 12 MB Level 3 Cache, 6 MB per core processor (Upgrade Only)
- 1.4
GHz with 12 MB Level 3 Cache, 6 MB per core 9120N processor
All
processors support:
- Level 2 Cache: 1 MB Instruction/256 KB Data per
core
- Level 1 Cache: 32 KB
- Four threads (two threads per core)
- Single
bit cache error correction
- 50 bit physical addressing
- 64 bit virtual
addressing
- 4 GB maximum page size
|
|
| Processor Configuration Rules |
- Processors can be installed one at a time
- Processors must be installed in the following sequence: 0, 1, 2, and
3
- Different speed and different cache size processors cannot be mixed
in the same system
|
|
| Memory Configuration
|
The HP Integrity rx6600 supports double data rate (DDR2) synchronous
dynamic random access memory (SDRAM) DIMMs with ECC and double chip spare
protection. The HP Integrity rx6600 can be ordered with one of the following
two memory carrier boards:
- AD126A-Supports from 2 GB minimum to 96 GB maximum memory; 8.5 GB/s
memory bandwidth. The AD126A can be replaced with the AD127A to increase
maximum memory beyond 96-GB and to a maximum of 192-GB, or to increase
memory bandwidth to 17.0 GB/s. Please note, there is no return credit
for the AD126A.
- AD127A-Supports from 2 GB minimum to 384 GB maximum memory; 17.0 GB/s
memory bandwidth.
|
| Memory Loading Rules |
- Memory must be installed in groups of four DIMMs, also known as quads
- Each quad must consist of equal density DIMMs
- Memory can be ordered in quads of 2 GB (4×512MB), 4 GB (4×1GB),
8 GB (4×2GB), 16 GB (4×4GB), or 32 GB (4x8GB)
- Minimum memory is 2 GB (4×512MB)
- Maximum memory is 384 GB, using twelve 16 GB memory quads in memory
carrier option AD127A
- Memory must be loaded in the order depicted on the memory carrier
board.
- Arrange DIMMs so that the quads with the largest capacity are in the
lowest numbered slots.
- For best performance, all DIMM slots on both memory carrier boards
should be populated with the same size DIMM.
|
| Memory Options |
| Description |
Product Number |
| 2-GB chip spare PC2-4200 ECC x4
single rank Registered DDR2 SDRAM memory quad (4×512MB DIMMs) |
AB563A |
| 4-GB chip spare PC2-4200 ECC x4
single rank Registered DDR2 SDRAM memory quad (4×1GB DIMMs) |
AB564A |
| 8-GB chip spare PC2-4200 ECC x4
single rank Registered DDR2 SDRAM memory quad (4×2GB DIMMs) |
AB565A |
| 16-GB chip spare PC2-4200 ECC
x4 single rank Registered DDR2 SDRAM memory quad (4×4GB DIMMs) |
AB566A |
| 32-GB chip spare PC2 4200 ECC
x4 single rank Registered DDR2 SDRAM memory quad (4×8GB DIMMs) |
AH405A |
|
Server Form Factor and Rack Configuration | The
HP Integrity rx6600 is a 7U rack optimized server. It is supported in HP 10000
G2 series cabinets. For factory integration order AD053A with 0D1 feature code.
Sliding mounts and a cable management arm will be installed with the server in
a factory integrated rack. The HP Integrity rx6600 can be installed in the
field with the Field Rack Kit (AD053A with B01 feature code). This field kit contains
the slide mounts, cable management arm, and all other hardware needed to mount
an rx6600 into a 19 inch cabinet. Refer to the 10000 G2 Series Rack Best
Practices Guide for information on rack deployment, stabilization and transportation.
Go to: http://www.hp.com/go/rackandpower
for more information. The rx6600 is also available in a stand-alone, pedestal
form factor (AD308A). Kit will be shipped in a separate box for field installation
only. |
|
| I/O
Architecture | | The
HP Integrity rx6600 supports two I/O backplane options in order to provide maximum
flexibility, I/O card availability, performance, scalability and reliability.
The two options are a PCI-X 2.0 Backplane (AD296A Option Code 100) or a PCI-Express
Backplane option (AD296A OptionCode 300). Only one backplane per system is supported. PCI-X
2.0 Backplane: This backplane provides ten PCI X I/O slots, two of which
are reserved for Core I/O cards, and eight of which are available for I/O card
expansion. The Core I/O slots will always be filled with either an HP PCI X 8
Internal Port Serial Attached SCSI (SAS) host bus adapter (for HP UX and OVMS
systems) or an HP PCI X Smart Array (P600) 8 Internal Port Serial Attached SCSI
(SAS) card (for Windows and Linux systems) (slot #1) and a PCI X dual port 10/100/1000Base
TX LAN adapter (slot #2). Each port of a Serial Attached SCSI card can be
connected to a Serial Attached SCSI hard disk drive. When more than eight hard
disk drives are required, a second HP PCI-X 8 port SAS card must be ordered. This
second SAS card will be installed in the second core I/O slot, and the PCI-X dual
port 10/100/1000Base TX LAN adapter will be moved out to a standard I/O slot.
Note that when the LAN adapter is moved out to a standard I/O slot, Wake On LAN
is not supported. HP-UX and OpenVMS based systems with PCI-X
2.0 Backplane: Must choose the HP PCI-X 8 Internal Port Serial Attached
SCSI host bus adapter for Core I/O controller (AB036B Option Code 006 or Option
Code 106). If factory configured RAID is not desired, select Option Code 006.
If factory configured RAID-1 is desired, select Option Code 106. RAID-1 only is
supported on the HP PCI-X 8 Internal Port SAS host bus adapter. When selecting
Option Code 106, a minimum of 2 HDD's of the same size and speed are required.
A maximum of two internal RAID 1 volumes (2×2 HDDs) and a disk for global
hot spare, for a maximum of five disks in RAIDed arrays is supported. The additional
three drives (of the maximum of eight drives supported on the controller) can
be accessed normally, but not configured for RAID. When from 9 to 16 HDD's are
ordered, a second SAS Controller is required to support disks 9 through 16. The
second controller cannot be factory configured for RAID (unless it is done through
Factory Express). For customer/field configured RAID arrays, the same limitations
(two RAID 1 arrays and one global hot spare) exist. The additional three HDDs
(14 through 16) can be accessed normally, but not configured for RAID. Please
see rx6600 Ordering Guide for factory configuration details. Please note that
MirrorDisk/UX is available for SW Mirroring on all HDDs in HP-UX based systems
and HP Volume Shadowing (software Raid 1) for HDDs in OpenVMS-based systems. Windows
and Linux based systems with PCI-X 2.0 Backplane: Must choose the HP PCI-X
8 port Smart Array (P600) Serial Attached SCSI (SAS) controller for Core I/O controller
(AB036B Option 100, or Option 500, or Option 510). Option 100 provides for factory
configuration of RAID-1 (requires a minimum of 2 HDDs). Option 500 provides for
factory configuration of RAID-5 (requires a minimum of 3 HDDs). Option 510 provides
for factory configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs must
be the same size and speed. When from 9 to 16 HDDs are ordered, a second SAS Controller
is required to support disks 9 through 16. The second controller cannot be factory
configured for RAID (unless it is done through Factory Express). Please see rx6600
Ordering Guide for details. Remaining Eight (non-Core I/O) slots:
The two slots (#3 and #4) next to the Core I/O slots have their own dedicated
64 bit 266 MHz PCI X bus and their own independent 2.1 GB/s I/O channel. These
slots should be used for high performance PCI X cards, such as clustering interconnects
or multi port storage adapters. The next two slots (slots #5 and #6) each have
their own dedicated 64 bit 133 MHz PCI X bus and their own independent 1.1 GB/s
I/O channel. The independent buses and I/O channels provide improved performance
and error containment. Independence protects each I/O card from bus hangs or extended
latencies due to the failure or high bandwidth demands of other I/O cards. Independence
also ensures that each I/O card can achieve maximum throughput. The remaining
four slots (#7 through #10) share two 64 bit 66 MHz PCI X buses, with two slots
allocated to each bus. Each pair of slots shares a 0.5 GB/s I/O channel. NOTE:
Hot plug operations are not supported with the Linux or OpenVMS operating
systems or in the core I/O slots with any operating system. All I/O slots
are keyed for I/O cards with 3.3V signaling. Cards that use 5V signaling are not
supported in the HP Integrity rx6600. PCI-Express
Backplane: This backplane also provides ten I/O slots. There are two PCI
X Core I/O slots; one PCI X Core I/O slot will always have a PCI X dual port 10/100/1000Base
TX LAN adapter (slot #2), unless a second storage controller is required, in which
case the second controller is configured in slot #2 and the LAN card is moved
out to public slot #10, and one PCI X Core I/O slot is provided in the case that
the HP PCI X 8 Internal Port Serial Attached SCSI (SAS) host bus adapter is chosen
when ordering an HP UX or OpenVMS based system, or if an HP PCI X Smart Array
(P600) 8 Internal Port Serial Attached SCSI (SAS) card is chosen (slot #1) when
ordering a Windows or Linux based system. If a PCI Express 8 port Smart Array
(P400, supports only internal connection to SAS disks) Serial Attached SCSI controller
(supported with HP UX, OpenVMS, Windows, and Linux) is chosen, or if a PCI Express
16 port (8 internal ports and 8 external ports) Smart Array (P800) Serial Attached
SCSI controller (for Windows and Linux only, also supports connection to external
SAS disks) is chosen, the PCI X Core I/O slot remains empty and the PCI Express
controller is installed in slot #3. Each port of a Serial Attached SCSI
card can be connected to a Serial Attached SCSI hard disk drive. When more than
eight hard disk drives are required, a second 8 port Serial Attached SCSI card
must be ordered. If a PCI-X card is chosen, it will be installed in the reserved
PCI-X core I/O slot. If a PCI-Express card is chosen, it will be installed in
slot #4. HP-UX and OpenVMS based systems with PCI-Express Backplane:
These systems have the two choices for Core I/O controller; the HP PCI-X 8 Internal
Port Serial Attached SCSI host bus adapter or the HP PCI-Express 8 Internal Port
Smart Array (P400) Serial Attached SCSI controller. - HP PCI-X
8 Internal Port Serial Attached SCSI host bus adapter (AB036B Option Code 006
or Option Code 106). If factory configured RAID is not desired, select Option
Code 006. If factory configured RAID-1 is desired, select Option Code 106. RAID-1
only is supported on the HP PCI-X 8 Internal Port SAS host bus adapter. When selecting
Option Code 106, a minimum of 2 HDD's of the same size and speed are required.
A maximum of two internal RAID 1 volumes (2×2 HDDs) and a disk for global
hot spare, for a maximum of five disks in RAIDed arrays is supported. The additional
three drives (of the maximum of eight drives supported on the controller) can
be accessed normally, but not configured for RAID. When from 9 to 16 HDD's are
ordered, a second SAS Controller is required to support disks 9 through 16. The
second controller cannot be factory configured for RAID (unless it is done through
Factory Express). For customer/field configured RAID arrays, the same limitations
(two RAID 1 arrays and one global hotspare) exist. The additional three HDDs (14
through 16) can be accessed normally, but not configured for RAID. Please see
rx6600 Ordering Guide for factory configuration details. Please note that MirrorDisk/UX
is available for SW Mirroring on all HDDs in HP-UX based systems and HP Volume
Shadowing (software Raid 1) for HDDs in OpenVMS-based systems.
- PCI-Express
8-port Smart Array (P400) Serial Attached SCSI Controller (AB036B Option 130,
or Option 530, or Option 540). Requires PCI-Express Backplane (AD296A Option 300).
Option 130 provides for factory configuration of RAID-1 (requires a minimum of
2 HDDs). Option 530 provides for factory configuration of RAID-5 (requires a minimum
of 3 HDDs). Option 540 provides for factory configuration of RAID-6 (requires
a minimum of 4 HDDs). All HDDs must be the same size and speed. When from 9 to
16 HDDs are ordered, a second SAS Controller is required to support disks 9 through
16. The second controller cannot be factory configured for RAID (unless it is
done through Factory Express). Please see rx6600 Ordering Guide for details.
NOTE:
MirrorDisk/UX is available for SW Mirroring on all HDDs in HP UX based systems
and HP Volume Shadowing (software Raid 1) for HDDs in OpenVMS-based systems.
Windows and Linux based systems with PCI-Express Backplane:
These system have three choices for Core I/O controller; the PCI-X 8 Internal
Port Smart Array (P600) Serial Attached SCSI controller, or the PCI-Express 8
Internal Port Smart Array (P400) Serial Attached SCSI controller, or the PCI-Express
16-port (8 Internal/8 External) Smart Array (P800) Serial Attached SCSI controller.
- HP PCI-X 8 port Smart Array (P600) Serial Attached SCSI controller
(AB036B Option 100, or Option 500, or Option 510). Option 100 provides for factory
configuration of RAID-1 (requires a minimum of 2 HDDs). Option 500 provides for
factory configuration of RAID-5 (requires a minimum of 3 HDDs). Option 510 provides
for factory configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs must
be the same size and speed. When from 9 to 16 HDDs are ordered, a second SAS Controller
is required to support disks 9 through 16. The second controller cannot be factory
configured for RAID (unless it is done through Factory Express) . Please see rx6600
Ordering Guide for details.
- PCI-Express 8-port Smart Array (P400)
Serial Attached SCSI Controller (AB036B Option 130, or Option 530, or Option 540).
Requires PCI-Express Backplane (AD296A Option 300). Option 130 provides for factory
configuration of RAID-1 (requires a minimum of 2 HDDs). Option 530 provides for
factory configuration of RAID-5 (requires a minimum of 3 HDDs). Option 540 provides
for factory configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs must
be the same size and speed. When from 9 to 16 HDDs are ordered, a second SAS Controller
is required to support disks 9 through 16. The second controller cannot be factory
configured for RAID (unless it is done through Factory Express) . Please see rx6600
Ordering Guide for details.
- PCI-Express 16-port Smart Array (P800)
Serial Attached SCSI Controller (AB036B Option 150, or Option 550, or Option 560).
Requires PCI-Express Backplane (AD296A Option 300). Option 150 provides for factory
configuration of RAID-1 (requires a minimum of 2 HDDs). Option 550 provides for
factory configuration of RAID-5 (requires a minimum of 3 HDDs). Option 560 provides
for factory configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs must
be the same size and speed. When from 9 to 16 HDDs are ordered, a second SAS Controller
is required to support disks 9 through 16. The second controller cannot be factory
configured for RAID (unless it is done through Factory Express) . Please see rx6600
Ordering Guide for details.
Remaining Eight (non-Core I/O)
slots: The two slots (#3 and #4) next to the Core I/O slots share a PCI-Express
x8 1.3-GB/s I/O channel. The next two slots (slots #5 and #6) each have their
own PCI-Express x8 2.6-GB/s I/O channel. The independent I/O channels provide
improved performance and error containment. Independence protects each I/O card
from bus hangs or extended latencies due to the failure or high bandwidth demands
of other I/O cards. Independence also ensures that each I/O card can achieve maximum
throughput. These slots should be used for high performance PCI X cards, such
as clustering interconnects or multi port storage adapters. The remaining
four slots (#7 through #10) are PCI-X slots. Slots #7 and #8 each have their own
dedicated 64 bit 133 MHz PCI-X channel; slot #7 is 1.1 GB/s and slot #8 is 0.5
GB/s. Slots #9 and #10 share a 64-bit 66-MHz PCI-X 0.5 GB/s I/O channel. NOTE:
Hot plug operations are not supported with the Linux or OpenVMS operating
systems or in the PCI X Core I/O slots with any operating system. Hot plug operations
are not supported for any operating system in slots #3 or #4. All I/O slots
are keyed for I/O cards with 3.3V signaling. Cards that use 5V signaling are not
supported in the HP Integrity rx6600. | |
|
| Supported
I/O Cards | | |
| Supported HP-UX I/O Cards |
|
I/O Card | Product
Number | PCIe/
PCI-X | Boot
Support | Connector
Type(s) | Maximum
Cards PCI-X Backplane |
Maximum Cards PCI-Express Backplane |
Special Notes | | Multi
function Cards (Mass Storage/LAN) | | HP
PCI-X 1 port 4 GB Fibre Channel/1 port 1000Base T Adapter |
AD193A |
PCI-X |
Yes |
1 LC, 1 RJ-45 |
8 | 4 |
| | HP
PCI-X 2 port 4 GB Fibre Channel/2 port 1000Base T Adapter |
AD194A |
PCI-X |
Yes |
2LC, 2 RJ-45 |
8 | 4 |
| | PCI-X 2 Gb Fibre Channel/1000Base SX |
A9782A |
PCI-X |
Yes |
LC | |
| For
maximum performance, card should not be installed in a shared slot. |
| PCI-X 2 port 1000Base T/2 port
U320 Multi function Adapter | AB290A |
PCI-X |
Yes |
SCSI - LVD/SE LAN - RJ-45 |
6 | 2 |
Card cannot be in a shared slot with an AB551A graphics card.
Requires full length slot. | | Local
Area Network (LAN) Adapters |
| PCIe 4-Gb Fibre Channel/GbE-T HBA
combo | AD221A |
PCIe |
Yes |
| 0 |
4 | |
| PCIe 2-port 4-Gb Fibre Channel/2-port
GbE-T HBA combo | AD222A |
PCIe |
Yes |
| 0 |
4 | |
| PCIe 2-port 4-Gb Fibre Channel/2-port
GbE-SX HBA combo | AD393A |
PCIe |
Yes |
| 0 |
4 | |
| PCI-X 1 port 1000Base T (gigabit
copper) | AD331A |
PCI-X |
No | RJ-45 | 8 |
4 | |
| PCI-X 2 port 1000Base T |
A7012A |
PCI-X |
Yes |
RJ-45 |
8 | 4 |
| | PCI-X 4 port 1000Base T 1GbE Adapter |
AB545A |
PCI-X |
Yes |
RJ-45 |
8 | 4 |
| | PCI-X 1 port 1000Base SX (gigabit fiber) | AD332A | PCI-X | No | Duplex
SC | 8 | 4 | |
| PCI-X 2 port 1000Base SX |
A7011A |
PCI-X |
Yes |
Duplex SC |
8 | 4 |
| | PCI-X 1 port 10GbE | AB287A |
PCI-X |
Yes |
Duplex LC |
4 | 2 |
For best performance, recommend at least one processor core
per card installed in the system. Each card requires 512 MB of memory. Card cannot
be installed in a shared slot. | | HP
PCIe 2-port 1000Base-T card | AD337A |
PCIe |
Yes |
RJ-45 |
0 | 4 |
| | HP
PCIe 2-port 1000Base-SX card | AD338A | PCIe | Yes | Duplex
SC | 0 | 4 | |
| PCIe 2-port 4X DDR Fast IB HCA |
AH304A |
PCIe |
No |
| 0 |
4 | |
| HP PCI-e 10GbE SR card |
AD386A |
PCIe |
Yes |
| 0 |
4 | |
| PCIe 4-port HP NC364T Gbit Adapter |
AD339A |
PCIe |
Yes |
| 0 |
4 | |
| PCI-X 266-MHz 1 port 10GbE |
AD385A |
PCI-X |
Yes |
Duplex LC |
4 | 2 | For
best performance, recommend at least one processor core per card installed in
the system. Each card requires 512 MB of memory. Card cannot be installed in a
shared slot. | | Fibre
Channel Storage Network Adapters Cards | | HP
PCIe 1-port 4-Gb/s Fibre Channel HBA |
AD299A |
PCIe |
No | LC |
0 | 2 |
| | HP
PCIe 2-port 4-Gb/s Fibre Channel HBA |
AD355A |
PCIe |
No | LC |
|
2 | |
| PCI-X 266 MHz 1 channel 4 Gb/s
Fibre Channel | AB378B |
PCI-X |
Yes |
LC | 8 |
4 | |
| PCI-X 266 MHz 2 channel 4 Gb/s
Fibre Channel | AB379B |
PCI-X |
Yes |
LC | 8 |
4 | |
| PCIe 2 port 4 Gb/s Fibre Channel |
AD300A |
PCIe |
Yes |
LC | 0 |
2 | |
| SCSI and SAS Adapter Cards for
External Storage | | PCI
2 channel Ultra320 SCSI | A7173A |
PCI-X |
Yes |
VHDCI |
8 | 4 |
| | HP
PCIe SC44Ge SAS HBA | AH303A | PCIe | Yes | | 0 | 4 | | | HP
PCIe 1-port 8Gb FC SR (Qlogic) HBA | AH400A | PCIe | Yes | | 0 | 2 | Total
of four cards are supported with the AB463-2163A backplane, making slots 3 and
4 possible. Without the new backplane, PCIe Gen2 cards do not function in those
slots | | HP PCIe 2-port
8Gb FC SR (Qlogic) HBA | AH401A | PCIe | Yes | | 0 | 2 | Total
of four cards are supported with the AB463-2163A backplane, making slots 3 and
4 possible. Without the new backplane, PCIe Gen2 cards do not function in those
slots | | RAID Adapters
Cards | | PCI-X 2 channel
Smart Array 6402 Ultra320 | A9890A |
PCI-X |
Yes |
VHDCI |
6 | 2 | Requires
minimum of 512 MB of memory and full length slot | | PCI-X 4 channel Smart Array 6404 Ultra320 |
A9891A |
PCI-X |
Yes |
VHDCI |
6 | 1 |
Requires minimum of 512 MB of memory and full length slot |
| PCIe Smart Array P800 |
AD335A |
PCIe |
Yes |
Mini SAS |
0 | 4 |
| | Wide
Area Network (WAN) Adapters | 2
port Programmable Serial Interface (PSI) X.25/Frame Relay/SDLC | J3525A | PCI-X | No | RS
530, RS 232, V.35, RS 449 or X.21 | 8 | 4 | |
| Cluster Interconnect | | PCI-X
2 port 4x Fabric (HPC) Adapter | AB286C | PCI-X | No | 4x
Infiniband Copper | 8 | 4 | For
maximum performance, card should not be installed in a shared slot. Requires a
minimum of 512 MB memory. | | PCIe
2 port 4x Fabric (PHC) Adapter | AD313A | PCIe | No | 4x
Infiniband Copper | 0 | 4 | | | PCI
8 port Serial MUX Adapter | AD278A | PCI-X | No | | 8 | 4 | | | PCI
64 port Serial MUX Adapter | AD279A | PCI-X | No | | 8 | 4 | | | 16
port RS 232 RJ45 Port Module | AD280A | | No | 4
per AD279A | N/A | N/A | AD280A
#001 Port Module Power Supply, required on Port Module (3) and Port Module (4)
connected to an AD279A 64 port MUX adapter. | | 16-port
RS-232 DB-25 Port Module | AD281A | | No | 4
per AD279A | N/A | | AD281A
#001 Port Module Power Supply, required on Port Module (3) and Port Module (4)
connected to an AD279A 64 port MUX adapter. | | Graphics
Cards | | HP 2D PCI-X graphics
card | AH391A | PCI | No | VGA | 2 | 2 | Replacing
AB551A. T/P/I: HP UX PCI-x and PCI-x/PCI-e 2/2/2 |
| | | Supported
OpenVMS I/O Cards |
| I/O Card |
Product Number |
PCIe/ PCI-X |
Boot Support |
Connector Type(s) |
Maximum Cards PCI-X Backplane |
Maximum Cards PCI-Express Backplane |
Special Notes | | Combination
Cards | | HP PCI-X 1 port
4 GB Fibre Channel/1 port 1000Base T Adapter |
AD193A |
PCI-X |
Yes |
1 LC, 1 RJ-45 |
2 | 2 |
| | HP
PCI-X 2 port 4 GB Fibre Channel/2 port 1000Base T Adapter |
AD194A |
PCI-X |
Yes |
2LC, 2 RJ-45 |
2 | 2 |
| | PCI-X 2 Gb Fibre Channel/1000Base SX |
A9782A |
PCI-X |
Yes |
LC | 4 |
4 |
For maximum performance, card should not be installed in a shared
slot. | | PCI-X 2
port 1000Base T/2 port U320 Multi function Adapter |
AB290A |
PCI-X |
Yes |
SCSI - LVD/SE LAN - RJ-45 |
2 | 2 | Requires
full length slot. | | Local
Area Network (LAN) Adapters | | PCI-X 1 port 1000Base T (gigabit copper) |
AD331A |
PCI-X |
No | RJ-45 | 8 |
4 | |
| PCI-X 2 port 1000Base T |
A7012A |
PCI-X |
No | RJ-45 | 8 |
4 | |
| HP PCI-X 4-Port 1000Base-T Gigabit
Adapter | AB545A |
PCI-X |
Yes |
| 3 |
3 | |
| PCI-X 1 port 1000Base SX (gigabit
fiber) | AD332A |
PCI-X |
No | Duplex
SC | |
4 | |
| PCI-X 2 port 1000Base SX |
A7011A |
PCI-X |
No | Duplex
SC | |
4 | |
| PCI-X 1 Port 10GbE |
AB287A |
PCI-X |
No | Duplex
LC | 2 |
2 | |
| HP PCIe 2-port 1000Base-T Card |
AD337A |
PCIe |
Yes |
| 0 |
4 | | | HP
PCIe 2-port 1000Base-SX Card | AD338A | PCIe | Yes | | 0 | 4 | | | PCIe
4-port HP NC364T Gbit Adapter | AD339A | PCIe | No | | 0 | 4 | | | AD385A
- HP PCI-X 266MHz 10GigE SR Card | AD385A | PCI-X | Yes | | 2 | 2 | |
| Fibre Channel Storage Network
Adapters Cards | | HP PCIe
1-port 4-Gb/s Fibre Channel HBA |
AD299A |
PCIe |
No |
LC |
0 |
4 | |
| HP PCIe 2-port 4-Gb/s Fibre Channel
HBA | AD355A |
PCIe |
No | LC |
|
|
| | PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel |
AB378B |
PCI-X |
Yes |
LC |
8 |
4 | |
| PCI-X 266 MHz 2 channel 4 Gb/s
Fibre Channel | AB379B |
PCI-X |
Yes |
LC |
8 |
4 | |
| PCIe 2 port 4 Gb/s Fibre Channel |
AD300A |
PCIe |
Yes |
LC |
0 |
4 | |
| Fibre Channel Storage Network Adapters
Cards | | PCI 2 channel
Ultra320 SCSI | A7173A |
PCI-X |
Yes |
VHDCI |
4 | 4 |
No On Line Add and Replace support. | | HP
PCIe SC44Ge SAS HBA | AH303A | PCIe | Yes | | 0 | 4 | |
| RAID Adapters Cards | | PCI-X 2 channel Smart Array 6402 Ultra320 | A9890A | PCI-X | Yes | VHDCI | 2 | 2 | Requires
minimum of 512 MB of memory and full length slot | | PCI-X 2 channel Smart Array 6404 Ultra320 | A9891A | PCI-X | Yes | VHDCI | 1 | 1 | Requires
minimum of 512 MB of memory and full length slot | | PCIe
Smart Array P800 | AD335A | PCIe | Yes | Mini
SAS | 0 | 4 | |
| Graphics Cards | | HP
OpenVMS, HP UX PCI Graphics Card | AB551A | PCI | No | VGA | 4 | 3 | Field
installation only. Can be installed in slots 5, 6, 7, 9 on PCI-X backplane. Can
be installed in slots 7, 8, 9 on PCI-e backplane. Slot 9 can be shared with core
LAN in slot 10. | | HP 2D
PCI-X graphics card | AH391A | PCI | No | VGA | 4 | 3 | Replacing
AB551A. No OpenVMS factory integration. AH391A offers 2D graphics support.
Support available for OpenVMS 8.3-1h1 and 8.3. OpenVMS PCI-x 4/4/4, PCI-e
3/3/3 | | |
| Supported Windows I/O Cards |
|
I/O Card | Product
Number | PCIe/
PCI-X | Boot
Support | Connector
Type(s) | Maximum
Cards PCI-X Backplane |
Maximum Cards PCI-Express Backplane |
Special Notes | | Local
Area Network (LAN) Adapters | | PCI
2 port Windows/Linux 1000Base TX |
A9900A |
PCI-X |
No |
RJ-45 |
6 |
4 | No
On Line Add and Replace support. | | HP
PCI-X 2-port 1000Base-SX (optical) Gigabit Adapter |
A7011A |
PCI-X |
Yes |
|
6 |
4 | |
| PCI-X 1 port 10 GbE |
AD144A |
PCI-X |
Yes |
Duplex LC |
4 |
4 | Each
card requires 512 MB of memory. Card cannot be installed in a shared slot. |
| HP PCIe 2-port 1000Base-T card |
AD337A |
PCIe |
Yes |
RJ-45 |
0 |
4 | |
| HP PCIe 2-port 1000Base-SX card |
AD338A |
PCIe |
Yes |
Duplex SC |
0 |
4 | |
| PCI-X 266 MHz 1 channel 4 Gb/s
Fibre Channel | AB429A |
PCI-X |
Yes |
LC |
6 |
4 | | | PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel | AB379B | PCI-X | Yes | LC | 6 | 4 | Replaces
AB379A | | PCI-X 266 MHz
1 channel 4 Gb/s Fibre Channel | AD167A | PCI-X | Yes | LC | 6 | 4 | | | PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel | AD168A | PCI-X | Yes | LC | 6 | 4 | | | PCIe
1 port 4 Gb/s Emulex Fibre Channel | A8002A | PCIe | Yes | LC | 0 | 4 | | | PCIe
2 port 4 Gb/s Emulex Fibre Channel | A8003A | PCIe | Yes | LC | 0 | 4 | | | PCIe
1 port 4 Gb/s Fibre Channel | AE311A | PCIe | Yes | LC | 0 | 4 | | | PCIe
2 port 4 Gb/s Fibre Channel | AD300A | PCIe | Yes | LC | 0 | 4 | | | SCSI
and SAS Adapter Cards for External Storage | | PCI
2 channel Ultra320 SCSI | A7173A | PCI-X | Yes | VHDCI | 2 | 2 | | | PCIe
Smart Array P500 | AH226A | PCIe | Yes | Mini
SAS | 0 | 4 | | | PCI-X Smart Array P600 Serial Attached SCSI (SAS) Controller (for external storage
only) | 337972-B21 | PCI-X | Yes | SFF8470 | 6 | 4 | A
maximum of (4) may be ordered with #0D1, the remaining (2) must be ordered without
#0D1 | | 512 MB cache memory
upgrade for SA640x and SA P600 controller | 372538-B21 | PCI-X | N/A | N/A | N/A | N/A | | | PCIe
Smart Array P800 | AD335A | PCIe | Yes | Mini
SAS | 0 | 4 | |
| |
| Supported Linux (RHEL 4 U4 and
SLES 10) I/O Cards |
| I/O Card |
Product Number |
PCIe/ PCI-X |
Boot Support |
Connector Type(s) |
Maximum Cards PCI-X Backplane |
Maximum Cards PCI-Express Backplane |
Special Notes | | Local
Area Network (LAN) Adapters | | PCI
2 port Windows/Linux 1000Base TX |
A9900A |
PCI-X |
No | RJ-45 | 8 |
4 | No
On Line Add and Replace support. | | HP
PCI-X 2-port 1000Base-SX (optical) Gigabit Adapter |
A7011A |
PCI-X |
Yes |
| 8 |
4 | |
| HP PCIe 2-port 1000Base-T card |
AD337A |
PCIe |
Yes |
RJ-45 |
0 | 4 |
| | HP
PCIe 2-port 1000Base-SX card | AD338A | PCIe | Yes | Duplex
SC | 0 | 4 | | | AD385A
- HP PCI-X 266MHz 10GigE SR Card | AD385A | | Yes | | 2 | 2 | | | Fibre
Channel Storage Network Adapters | | PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel | AB429A | PCI-X | Yes | LC | 4 | 2 | Qlogic
and Emulex HBAs are not supported in the same server. | | PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel | AB379B | PCI-X | Yes | LC | 4 | 2 | Replaces
AB379A | | PCI-X 266 MHz
1 channel 4 Gb/s Fibre Channel | AD167A | PCI-X | Yes | LC | 6 | 0 | Qlogic
and Emulex HBAs are not supported in the same server. No On Line Add and Replace
support. | | PCI-X 266 MHz
2 channel 4 Gb/s Fibre Channel | AD168A | PCI-X | Yes | LC | 6 | 0 | Qlogic
and Emulex HBAs are not supported in the same server. No On Line Add and Replace
support. | | PCIe 1 port
4 Gb/s Emulex Fibre Channel | A8002A | PCIe | Yes | LC | 0 | 4 | | | PCIe
2 port 4 Gb/s Emulex Fibre Channel | A8003A | PCIe | Yes | LC | 0 | 4 | | | PCIe
1 port 4 Gb/s Fibre Channel | AE311A | PCIe | No | LC | 0 | 4 | | | PCIe
2 port 4 Gb/s Fibre Channel | AD300A | PCIe | Yes | LC | 0 | 4 | | | SCSI
and SAS Adapter Cards for External Storage | | PCI
2 channel Ultra320 SCSI | A7173A | PCI-X | Yes | VHDCI | 4 | 4 | No
On Line Add and Replace support. | | HP
PCIe Smart Array E500 SAS Controller | AH226A | PCIe | Yes | | 0 | 4 | | | HP
PCIe SC44Ge SAS HBA | AH303A | PCIe | No | | 0 | 4 | Connect
to external SAS tape drives only. | | RAID
Adapters Cards | | PCI-X
Smart Array P600 Serial Attached SCSI (SAS) Controller (for external storage only) | 337972-B21 | PCI-X | Yes | SFF8470 | 4 | 4 | | | 512
MB cache memory upgrade for SA640x and SA P600 controller | 372538-B21 | PCI-X | N/A | N/A | N/A | N/A | | | PCIe
Smart Array P800 | AD335A | PCIe | No | Mini
SAS | 0 | 4 | |
| Support Internal Storage Devices | Product
Number | | Device | |
| Internal
Hard Drives | |
| 36-GB
15K RPM Hot Plug Serial Attached SCSI (SAS) 2.5-inch Drive | AD378A |
| 72-GB
10K RPM Hot Plug Serial Attached SCSI (SAS) 2.5-inch Drive | AD141A |
| 72-GB
15K RPM Hot Plug Serial Attached SCSI (SAS) 2.5-inch Drive |
AD379A | | 146-GB
10K RPM Hot Plug Serial Attached SCSI (SAS) 2.5-inch Drive | AD333A |
| Removable
Media* | |
| DVD
ROM Drive | AD142A |
| DVD+RW
Drive** (Not supported on HP-UX at this time) | AD143A |
*
Required for Windows, Linux and OpenVMS. Optional for HP UX. Maximum 1 supported.
** Third party software (not included with AD143A) is required to support
DVD write with Windows on AD143A. | |
|
Integrated Multi-function Core I/O |
The integrated multifunction I/O provides core I/O functionally and includes
the integrated management processor, which provides remote management
and high availability monitoring capabilities.
- PCI-X Dual port 10/100/1000Base T LAN with RJ 45 connector-Supports
LAN boot for operating system installation.
- The base system offerings require choice of at least one HP 8 Port
Serial Attached SCSI (SAS) controller. Choices vary depending on choice
of I/O backplane (PCI-X 2.0 backplane or PCI-Express backplane) and
choice of operating system. Please see Table 2.9.2 HP Integrity rx6600
Features - Standard System Features ealier in this chapter, or the section
I/O Architecture beginning on page 2-230, and the rx6600 Ordering Guide.
- Factory configured RAID is available with all Core I/O controllers.
Please see Table 2.9.2 HP Integrity rx6600 Features - Standard System
Features ealier in this chapter, or the section I/O Architecture beginning
on page 2-230, and the rx6600 Ordering Guide. When configuring for RAID,
all HDD's in the system must be the same size and speed.
|
|
| Integrated Integrity iLO 2
Management Processor Functionality |
- Dedicated 10/100BaseTX LAN port for LAN console and embedded web console
access.
- One RS 232 serial port for local console.
- Password protected console ports.
- Console mirroring between all local, modem, LAN, and web consoles.
- Remote power up and power down control.
- Configurable remote access control.
- Event notification to system console-Provides connectivity, information,
and support for HP UX tools (such as STM and EMS) to notify by email,
pager and/or HP response centers.
- Interface to system monitoring and diagnostic hardware via an internal
IC bus.
- Secure Sockets Layer security on web console.
- Support for Integrated Lights Out version 2 (iLO v2) Advanced Pack
activation key and license (AD301A). Firmware license installs on the
integrated Management Processor Card. Integrated Lights Out (iLO) Advanced
Pack provides additional remote management capabilities, including integrated
remote console and virtual CD/DVD drive, and LDAP directory services,
SSH security, and Group Actions with HP Systems Insight Manager (SIM).
- Basic graphic capabilities are available as an optional upgrade. The
upgrade provides these capabilities via the Radeon 7000 2D graphics
chip and 16 MB memory, which resides on the integrated Integrity iLO
2 management processor card. VGA port is provided on rear of the system.
Supported resolutions and refresh rates include:
|
| |
Operating System
|
Minimum Resolution
|
Refresh Rate
|
Maximum Resolution
|
Refresh Rate |
| HP-UX |
1024x768 |
75 Hz |
1920x1200 |
75 Hz |
| Linux |
1024x768 |
75 Hz |
1920x1200 |
75 Hz |
| Windows |
640x480 |
75 Hz |
1600x1200 |
75 Hz |
| OpenVMS |
640x480 |
60 Hz |
1920x1200 |
75 Hz |
|
|
|
System Console Configurations |
The HP Integrity rx6600's integrated Management
Processor Card provides six methods for console connections.
- SSL secured Web console accessible through the 10/100Base T management
LAN
- Standard telnet connections accessible through the 10/100Base T management
LAN
- Local VT100 or hpterm terminal, or VT100 or hpterm emulator via local
RS 232 serial connection
- Remote VT100 or hpterm terminal, or VT100 or hpterm emulator via external
modem
- VGA graphics console using the upgrade to the VGA port. This upgrade
is required for Windows systems and optional for HP UX and Linux systems.
Keyboard and mouse connections are provided by USB. OpenVMS doesn't
support VGA console for boot operations, but supports the VGA device
for graphics use after boot.
- Integrated Remote Console (virtual KVM) through the iLO 2 Advanced
Pack (Windows systems only).
|
|
|
Internal Disk and Media Drives |
- The HP Integrity rx6600 supports up to sixteen internal Serial Attached
SCSI (SAS) 2.5 inch hot plug disk drives.
- A PCI-X or PCI-Express 8 port host bus adapter provides 8 ports, 1
port per SAS disk, for point to point connection from the adapter to
the disk. This means that each disk has its own 3 GB link. A second
HP 8 Internal port host bus adapter must be ordered to support disks
9 through 16.
- Factory configured RAID is available with all Core I/O controllers.
Please see Table 2.9.2 HP
- Integrity rx6600 Features - Standard System Features ealier in this
chapter, or the section I/O Architecture beginning on page 2-230, and
the rx6600 Ordering Guide. When configuring for RAID, all HDD's in the
system must be the same size and speed.
- Cables required to connect the internal disk drives to the host bus
adapter are shipped with the system; no need to order separately.
- 36-GB 10K and 15K, 72-GB 10K and 15K, and 146-GB Serial Attached SCSI
(SAS) disks are supported. 300 GB 10K SAS disks will be supported on
all operating systems in a future release.
- Optical media drives include a DVD ROM (AD142A) and DVD+RW (AD143A).
A DVD drive is required for all OpenVMS, Linux, and Windows configurations.
Third party software (not included with the AD143A) is required to support
DVD write with Windows on AD143A. Please note that that the AD143A is
not supported on HP UX based systems.
|
|
| HP Integrity rx6600 Trusted
Platform Module
|
The rx6600 has an accessory option
for an embedded security chip - the Trusted Platforms Module (TPM) - product
number AB404A. HP-UX Trusted Computing Services (HP-UX TCS) provides software
support for the TPM when running HP-UX 11i v2. By providing a low-cost embedded
security chip option (known as a Trusted Platform Module) in its zx2-based
Integrity servers (rx2660, rx3600, and rx6600), HP has established a foundation
for strong protection of sensitive information - including cryptographic
keys. Built around industry standards, the Trusted Platform Module (TPM)
provides a basis for key storage by securely generating and storing cryptographic
keys. HP-UX 11i TCS takes this a step further by providing the necessary
infrastructure for managing the TPM, as well as integrating it into select
features such as HP-UX Encrypted Volumes and File Systems (EVFS).
Using HP-UX TCS with EVFS:
Using HP-UX TCS to make the unattended boot capability of EVFS more secure
is an important example of how HP-UX TCS can be integrated with other
applications to enhance security. For more information see the "Protecting
EVFS Keys with HP-UX TCS" chapter in the "HP-UX Trusted Computing
Services Administrators Guide" available in the HP-UX Trusted Computing
Services section at: http://docs.hp.com/en/internet.html
Please note that HP-UX 11iTCS requires:
(1) An HP zx2-based Integrity server (rx2660, rx3600, or rx6600) with
a TPM installed, running HP-UX 11iv2 September 2006 release or later
(2) Installation of kernel patch PHKL_35428
To download TCS and EVFS, please see the HP-UX Software Depot web page
at: http://software.hp.com
|
|
| HP Integrity rx6600 Power Subsystem |
The HP Integrity rx6600 provides a high level of integrated power protection:
- N+1 redundant hot swap power supplies
- N+1 redundant AC power input protection with electrical phase isolation
- Power monitoring and control
The HP Integrity rx6600 supports a second hot swap power supply for N+1
protection. One supply is shipped as a standard part of every system and
is required for correct operation. The hot swap design allows for the
online replacement of a power supply when N+1=2 supplies are configured
in the server.
The HP Integrity rx6600 provides an independent power input receptacle
for each power supply. The independent design provides protection against
losing the connection from a power cord or breaker. The HP Integrity rx6600
power cords should always be plugged into separate breakers when possible.
|
Technical Specifications
| Server
model number | rx6600 | |
|
| Server product
numbers |
Four processor/eight core capable
HP Integrity rx6600 base system with one dual core processor module |
AB464A
|
| Configure with one 1.4 GHz/12
MB dual core 9120N processor module |
Option 240
|
| Configure with one 1.6 GHz/18
MB dual core 9140Nprocessor module |
Option 260
|
| Configure with one 1.6 GHz/24
MB dual core 9150Nprocessor module |
Option 280
|
| Base system includes one power
supply (second supply can be ordered for redundancy) and a 2 port 10/100/1000
GbE PCI X card in one core I/O slot. Must select core I/O storage controller,
I/O backplane, memory carrier board option, and memory (minimum 2 GB). |
|
| Four processor/eight core capable
HP Integrity rx6600 base system with two dual core processor modules |
AD132A
|
| Configure with two 1.4 GHz/12
MB dual core 9120Nprocessor modules |
Option 240
|
| Configure with two 1.6 GHz/18
MB dual core 9140Nprocessor modules |
Option 260
|
| Configure with two 1.6 GHz/24
MB dual core 9150Nprocessor modules |
Option 280
|
| Base system includes one power