Overview
|
HP Integrity rx2660 Server | |||
![]() | |||
| HP Integrity rx2660 System Overview (Top View) | |||
| 1. | 6 pairs redundant system fans (3 cooling zones) | 5. | 3-slot I/O cage 3 PCI-x or 2 PCI-e; 1 PCI-x |
| 2. | 8x DIMM slots | 6. | CPUs |
| 3. | N+1 power supplies | 7. | HDD cage |
| 4. | HP 8-port Smart Array SAS Controller (optional) | ||
| At A Glance |
| Standard System Features |
|
|
|
Standard Features
| Minimum System |
|
| | |
| Maximum Server Capacities |
|
| | |
| Standard System Features |
|
| | |
| High Availability |
|
| | |
| Security |
|
| | |
| Manageability-Monitor |
|
| | |
| Manageability-Optimize |
|
| | |
| Manageability-Deployment |
|
|
|
Configuration
| Processor Configuration | The HP Integrity rx2660 is a symmetrical multiprocessing (SMP) server supporting up to two high performance 64 bit Itanium processors. Processor speeds cannot be mixed within the same system. |
| | |
| Processor Details |
Single core Itanium processors:
Dual core Itanium processor:
|
|
All processors support:
|
|
|
|
|
| Memory Configuration | The HP Integrity rx2660 supports DDR (double data rate) SyncDRAM (synchronous dynamic random access memory) DIMMs with ECC and chip spare protection. The HP Integrity rx2660 has eight DIMM slots. A maximum of 32 GB is supported (8×4GB DIMMs). |
| Memory Loading Rules and Performance Guidelines | |
| |
| Supported Memory Options | |
| Description | Product Number |
| 2-GB chip spare PC2 4200 ECC x4 single rank Registered DDR2 SDRAM memory pair (2×1 GB DIMMs) | AD274A |
| 4-GB chip spare PC2 4200 ECC x4 single rank Registered DDR2 SDRAM memory pair (2×2 GB DIMMs) | AD275A |
| 8-GB chip spare PC2 4200 ECC x4 single rank Registered DDR2 SDRAM memory pair (2×4 GB DIMMs) | AD276A |
|
|
|
| Server Form Factors and Rack Configuration | The HP Integrity rx2660 is a 2U
server. It comes in 3 form factors: rack mounted, OFS (Office Friendly Server)
and pedestal versions. The rack mounted and OFS versions have the same base
model product numbers with different options. The rack mounted versions
are AH234A and AH235A options 001-003; the OFS are AH234A and AH235A options
004-006
The OFS is a pedestal form factor with reduced acoustics for workstation replacement and/or office environments. Note that the OFS does not support redundant fans or redundant power. Please note that the pedestal version is not factory installed-it is a kit (AD251A) that must be assembled on site. The rack mounted version of the rx2660 is supported in HP 10000 Series G2 cabinets. For factory integration order the Universal Rack Kit, AD253A, with 0D1 feature code. Sliding mounts and a cable management arm will be installed with the server in a factory integrated rack. The HP Integrity rx2660 can be installed in the field with the Universal Rack Kit (AD253A with B01 feature code). This kit contains the slide mounts, cable management arm, and all other hardware needed to mount an rx2660 into a 19 inch cabinet. Refer to the 10000 Series G2 Rack Best Practices Guide for information on rack deployment, stabilization, and transportation. Go to http://www.hp.com/go/rackandpower for more information. |
|
| |
| Non-HP Cabinets | For customers who choose to use
non HP cabinets, the HP Integrity rx2660 provides simple options for installation
and HP field support. The HP Integrity rx2660 field rack kit (AD253A) contains
adjustable slide rails, allowing the server to be mounted in cabinets that
use the four post EIA mounting system.
|
|
Once the server is mounted in a non HP cabinet, it must meet some simple
criteria to ensure that HP field personnel can fully support the rack
environment.
|
|
| | |
| I/O Architecture |
| The HP Integrity rx2660 I/O architecture
utilizes industry standard PCI X and PCI Express buses in a unique design
for maximum flexibility, I/O card availability, performance, scalability,
and reliability. The HP Integrity rx2660 I/O architecture consists of six dedicated I/O channels which provide up to 8.2 GB/s of I/O bandwidth allocated across standard I/O connectivity (with the Combo I/O backplane option), a dedicated slot for an optional 8 port Smart Array P400 Serial Attached SCSI (SAS) controller (mandatory with Windows based systems) and three open slots for additional, optional I/O card choices. The diagrams above show how these channels allocate bandwidth to the open I/O slots and to the integrated core I/O. The standard I/O connectivity is integrated on the rx2660 system board and includes an integrated HP 8 Internal Port SAS (Serially Attached SCSI) Host Bus Adapter, two 1000Base TX LAN ports, an RN50 graphics port, three USB v2.0 ports, and one general RS 232 Serial Port. Additionally, there is a standard Integrity iLO2 Management Processor with a rear RS 232 Serial Port. Each port of SAS Host Bus Adapter can be connected to a SAS hard disk drive. SAS is a point to point architecture, compared to Ultra320 SCSI which is a bus based architecture. With SAS, each disk has its own individual 3 GB link. NOTE: That there are two possible 'integrated' RAID controllers for the rx2660: AD248A#106 refers to the embedded SAS RAID controller. AD248A#130, AD248A#530 and AD248A#540 refers to an add-in SAS p400 Smart Array card which occupies a 'private' slot (does not use one of the system's PCI slots). HP UX, OpenVMS, and Linux support the integrated HP 8 Internal Serial
Attached SCSI host bus adapter (AD248A#106), which supports a maximum
of two RAID 1 volumes (2×2 HDDs) and a disk for global hotspare,
for a maximum of five disks in RAIDed arrays. The remaining three disks
(of the maximum eight disks that are supported) can be accessed normally,
but not configured for RAID. Please note that MirrorDisk/UX is available
for software mirroring on all HDDs in HP UX based systems, as HP Volume
Shadowing (software Raid 1) for HDDs in OpenVMS based systems. Windows
does not support this integrated HP 8 Internal Port SAS Host Bus Adapter.
All Windows systems must order the HP 8 Port SAS Smart Array P400 Serial
Attached SCSI (SAS) Controller Card (AD248A#130, AD248A#530, and AD248A#540),
which is also available as an optional choice for HP UX, OpenVMS, and
Linux systems. The HP 8 Port SAS Smart Array P400 Serial Attached SCSI
(SAS) Controller is accommodated via a dedicated PCI Express slot, which
provides up to 1.3 GB/s of sustained bandwidth. There is a mandatory choice of only one of two internal I/O card cage options, each option provides three I/O slots for I/O expansion within the system enclosure. The two I/O card cage options are an all PCI X Card Cage and a Combo Card Cage. The all PCI X Card Cage provides two PCI X 266 MHz 64 bit I/O slots and one PCI X 133 MHz 64 bit I/O slots (AD246A). Please note that this option (AD246A) is not supported with Windows based systems. Each slot of the AD246A has its own dedicated bus and its own independent I/O channel. An independent channel provides improved I/O performance and error containment. Independence protects each I/O card from bus hangs or extended latencies due to the failure or high bandwidth demands of other I/O cards. Independence also ensures that each I/O card can achieve maximum throughput. The two 266 MHz slots provide 2.1 GB/s of sustained bandwidth, while the one 133 MHz slot provides 1.1/GB/s of sustained bandwidth. The Combination Card Cage (AD247A) provides two PCI Express x8 slots
and one PCI X 133 MHz 64 bit I/O slot. Please note that the AD247A is
required for Windows based systems. Each slot of the AD247A has its own
dedicated bus and its own independent I/O channel. The two PCI Express
slots 2.6 GB/s of sustained bandwidth, while the one 133 MHz slot provides
1.1 GB/s of sustained bandwidth. All I/O slots are keyed for 3.3V I/O cards. 5V cards are not supported in the HP Integrity rx2660. OLAR (On-line add/remove) operations are not supported on the rx2660. The chart below provides further details on the standard I/O. |
| Bandwidth | Bus Width | Bus Speed | Slot Keying | ||
| HP 8 Internal Port SAS Host
Bus Adapter Core I/O. Supports up to 8 Internal SAS Disk Drives. NOTE: Not supported on Windows-based servers. |
Integrated on System Board | 512 MB/s, shared with 1000Base TX LAN Core I/O | 64 bits | 66 MHz | 3.3 Volts |
| 1000Base TX LAN Core I/O. | Integrated on System Board | 512 MB/s, shared with HP 8 Internal Port SAS Host Bus Adapter Core I/O. | 64 bits | 66 MHz | 3.3 Volts |
| RN50 Graphics (front or rear connection), 3 USB Ports (1 front, 2 rear), RS 232 General Serial Port | Integrated on System Board | 133 MB/s, shared among all functions | 32 bits | 33 MHz | 3.3 Volts |
| Integrity iLO2 Management Processor, 1 rear RS 232 Serial Port | Integrated on System Board | ||||
| Optional HP 8 Port SAS Smart
Array P400 Serial Attached SCSI (SAS) Controller Card NOTE: This card is mandatory for Windows-based systems. |
Private Slot | 1.3 GB/s | 64 bits | 3.3 Volts |
|
|
| HP Integrity rx2660 HP-UX 11i Supported I/O Cards |
| I/O Card |
Product Number
|
PCIe/
PCI-X |
Boot Support
|
Connector Type(s)
|
Maximum Cards
|
Special Notes
|
| Mass Storage Host Bus Adapters | ||||||
| PCIe 4Gb Fibre Channel / GbE-T HBA combo |
AD221A
|
PCIe
|
Yes
|
2
|
HP-UX 11i v3 only
|
|
| PCIe 2-port 4Gb Fibre Channel / 2-port GbE-T HBA combo |
AD222A
|
PCIe
|
Yes
|
2
|
HP-UX 11i v3 only
|
|
| PCIe 2-port 4Gb Fibre Channel / 2-port GbE-SX HBA combo |
AD393A
|
PCIe
|
Yes
|
2
|
HP-UX 11i v3 only
|
|
| HP PCIe 1 port 4 Gb/s Fibre Channel HBA |
AD299A
|
PCIe
|
Yes
|
LC
|
2
|
|
| HP PCIe 2 port 4 Gb/s Fibre Channel HBA |
AD355A
|
PCIe
|
Yes
|
LC
|
2
|
|
| PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel |
AB378B
|
PCI-X
|
Yes
|
LC
|
1
|
|
| PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel |
AB379B
|
PCI-X
|
Yes
|
LC
|
3
|
|
| PCIe 2 port 4 Gb/s Fibre Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
2
|
|
| PCI 2 channel Ultra320 SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
3
|
|
| HP PCIe SC44Ge SAS HBA | AH303A | PCIe | Yes | 2 | ||
| PCI-X 2 channel Smart Array 6402 Ultra320 | A9890A | PCI-X | Yes | VHDCI | 3 | |
| PCI-X 4 channel Smart Array 6404 Ultra320 | A9891A | PCI-X | Yes | VHDCI | 3 | |
| PCIe Smart Array P800 | AD335A | PCIe | Yes | Mini SAS | 2 | |
| HP1-port 8Gb PCIe FC SR QLogic
HBA |
AH400A | PCIe | Yes | 2 | HP-UX 11i v3 only | |
| HP 2-port 8Gb PCIe FC SR QLogic HBA | AH401A | PCIe | Yes | 2 | HP-UX 11i v3 only | |
| HP 1-port 8Gb PCIe FC SR Emulex HBA | AH402A | PCIE | Yes | 2 | HP-UX 11i v3 only | |
| HP 2-port 8Gb PCIe FC SR Emulex HBA | AH403A | PCIe | Yes | 2 | HP-UX 11i v3 only | |
| Local Area Network (LAN) Adapters | ||||||
| PCI-X 1-port 1000Base T |
AD331A
|
PCI-X
|
Yes
|
RJ-45
|
3
|
|
| PCI-X 1-port 1000Base SX |
AD332A
|
PCI-X
|
Yes
|
LC
|
3
|
|
| PCI-X 2 port 1000Base SX |
A7011A
|
PCI-X
|
Yes
|
Duplex SC
|
3
|
|
| PCI-X 2 port 1000Base T |
A7012A
|
PCI-X
|
Yes
|
RJ-45
|
3
|
|
| PCI-X 4-port 1000Base T Gbit Adapter |
AB545A
|
PCI-X
|
Yes
|
RJ-45
|
3
|
|
| PCI-X 266 MHz 1 port 10 GbE | AD385A | PCI-X | Yes | Duplex LC | 3/1 | 3 for rack version; 1 for OFS |
| HP PCIe 2 port 1000Base T card |
AD337A
|
PCIe
|
Yes
|
RJ-45
|
2
|
|
| HP PCIe 2 port 1000Base SX card |
AD338A
|
PCIe
|
Yes
|
Duplex SC
|
2
|
|
| HP PCI e 10GbE SR card |
AD386A
|
PCIe
|
Yes
|
2
|
|
|
| PCIe 4 port HP NC364T Gbit Adapter |
AD339A
|
PCIe
|
Yes
|
2
|
|
|
| Wide Area Network (WAN) Adapters | ||||||
| 2 port Programmable Serial Interface
(PSI) X.25/Frame Relay/SDLC |
J3525A |
PCI-X
|
No
|
RS 530, RS 232, V.35, RS 449 or X.21
|
3
|
|
| Cluster Interconnect | ||||||
| PCIe 2 port 4X DDR Fast IB HCA | AH304A | PCIe | No | 2 | HP-UX 11i v3 only | |
| PCI-X 2 port 4x Fabric (HPC) Adapter | AB286C | PCI-X | No | 4x Infiniband Copper | 3 | |
| Multi function Cards (Mass Storage/LAN) | ||||||
| PCI-X 2 port 1000Base T/2 port Ultra320 SCSI Multi function Adapter | AB290A | PCI-X | Yes | SCSI - LVD/SE LAN - RJ-45 |
3 | |
| PCI-X 2 Gb Fibre Channel/1000Base SX | A9782A | PCI-X | Yes | LC | 3 | |
| HP PCI-X 1 port 4 Gb Fibre Channel and 1 port 1000Base T Adapter | AD193A | PCI-X | Yes | (1) LC, (1) RJ-45 | 3 | |
| HP PCI-X 2 port 4 Gb Fibre Channel
and 2 port 1000Base T Adapter |
AD194A | PCI-X | Yes | (2) LC, (2) RJ-45 | 3 | - |
| HP PCIe 1-port 4Gb Fibre Channel and 1-port 1000BaseT Adapter | AD221A | PCIe | Yes | 2 | HP-UX 11i v3 only | |
| HP PCIe 2-port 4Gb Fibre Channel and 2-port 1000BaseT Adapter | AD222A | PCIe | Yes | 2 | HP-UX 11i v3 only | |
| HP PCIe 2-port 4Gb Fibre Channel and 2-port 1000BaseT Adapter | AD393A | PCIe | Yes | 2 | HP-UX 11i v3 only | |
| Additional Interface Cards | ||||||
| PCI 8-port Serial MUX Adapter |
AD278A
|
PCI-X
|
No
|
|
3
|
|
| PCI 64-port Serial MUX Adapter |
AD279A
|
PCI-X
|
No
|
|
3
|
|
| 16-port RS-232 RJ45 Port Module |
AD280A
|
PCI-X
|
No
|
|
4 per AD279A
|
AD280A #001 Port Module Power Supply, required on Port Module (3) and Port Module (4) connected to an AD279A 64P MUX adapter. |
| 16-port RS-232 DB25 Port Module |
AD281A
|
PCI-X
|
No
|
|
4 per AD279A
|
AD281A #001 Port Module Power Supply, required on Port Module (3) and Port Module (4) connected to an AD279A 64P MUX adapter. |
| HP PCI Audio Card |
AD317A
|
PCI-X
|
No
|
|
1
|
Factory Integration Only
|
| HP 2D PCI-X graphics card | AH391A | PCI-X | No | PCI-X only backplane:
2 Combo backplane: 1 |
AH391A offers 2D graphics support. Support available for HP UX v3 and v2 | |
|
|
| HP Integrity rx2660 Windows Server 2003 Supported I/O Cards |
|
NOTE: While ordering Windows Server
2008, do not mix differing brands of HBAs (Emulex and QLogic) within the
same server configuration in an MPIO environment. This is to avoid issues
which occur when different Fibre Channel HBAs are used within the same
server which support different I/O max transfer packet sizes in an MPIO
environment. For example, the Emulex Fibre Channel HBAs support a max
I/O transfer packet size of 1MB and the QLogic Fibre Channel HBAs support
a max I/O transfer packet size of 2MB. Mixing these two cards in an MPIO
configuration can cause the system to hit a BSOD 0X000000D1 with a reference
to elxstor.sys QLogic: |
| I/O Card |
Product Number
|
PCIe/
PCI-X |
Boot Support
|
Connector Type(s)
|
Maximum Cards
|
Special Notes
|
| Mass Storage Host Bus Adapters | ||||||
| PCI-X 1 port 4 Gb/s Fibre Channel |
AB429A
|
PCI-X
|
Yes 1
|
LC
|
1
|
|
| PCI-X 266 MHz 2 port 4 Gb/s Fibre Channel |
AB379B
|
PCI-X
|
Yes 1
|
LC
|
1
|
|
| PCIe 1 port 4 Gb/s Fibre Channel |
AE311A
|
PCIe
|
Yes 1
|
LC
|
2
|
|
| PCI-X 1-port 4-GB/s Fibre Channel |
AD300A
|
PCIe
|
Yes 1
|
LC
|
2
|
|
| PCI-X 1 port 4 GB/s Fibre Channel |
AD167A
|
PCI-X
|
Yes 1
|
LC
|
1
|
|
| PCI-X 2 port 4 GB/s Fibre Channel |
AD168A
|
PCI-X
|
Yes 1
|
LC
|
1
|
|
| PCIe 2 port 4 Gb/s Emulex Fibre Channel |
A8003A
|
PCIe
|
Yes 1
|
LC
|
2
|
|
| PCIe 1 port 4 Gb/s Emulex Fibre Channel |
A8002A
|
PCIe
|
Yes 1
|
LC
|
2
|
|
| PCI 2 channel Ultra320 SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
1
|
|
| PCIe Smart Array P800 |
AD335A
|
PCIe
|
Yes 2
|
Mini SAS
|
2
|
Only 1 will be factory integrated.
|
| PCIe Smart Array P500 |
AH226A
|
PCIe
|
Yes
|
Mini SAS
|
2
|
|
| PCI-X 1 port 4 Gb/s Fibre Channel |
AB429A
|
PCI-X
|
Yes 1
|
LC
|
1
|
|
| HP PCIe 1-port 8Gb FC SR (QLogic) HBA | AH400A | PCIe | Yes | 2 | ||
| HP PCIe 2-port 8Gb FC SR (QLogic) HBA | AH401A | PCIe | Yes | 2 | ||
| HP PCIe 1-port 8Gb FC SR (Emulex) HBA | AH402A | PCIe | Yes | 2 | ||
| HP PCIe 2-port 8Gb FC SR (Emulex) HBA | AH403A | PCIe | Yes | 2 | ||
| Local Area Network (LAN) Adapters | ||||||
| HP PCI-X 2-port 1000Base-SX (optical) Gigabit Adapter |
A7011A
|
PCI-X
|
Yes
|
1
|
|
|
| PCI 2 port 1000Base TX |
A9900A
|
PCI-X
|
Yes
|
RJ-45
|
1
|
|
| HP PCIe 2 port 1000Base T card |
AD337A
|
PCIe
|
Yes
|
RJ-45
|
2
|
|
| HP PCIe 2 port 1000Base SX card |
AD338A
|
PCIe
|
Yes
|
Duplex SC
|
2
|
|
| 1Boot
from fibre channel is supported, however not available directly from factory.
Boot support must be configured in field. 2Boot from external storage only. |
| |
| HP Integrity rx2660 Red Hat Enterprise Linux AS and ES Supported I/O Cards |
| I/O Card |
Product Number
|
PCIe/
PCI-X |
Boot Support
|
Connector Type(s)
|
Maximum Cards
|
Special Notes
|
| Mass Storage Host Bus Adapters | ||||||
| PCI-X Smart Array P600 Serial Attached SCSI (SAS) Controller |
337972 B21
|
PCI-X
|
Yes
|
SFF8470
|
1
|
|
| PCI-X 1 port 4 Gb/s Fibre Channel |
AB429A
|
PCI-X
|
Yes
|
1
|
|
|
| PCI-X 266 MHz 2 port 4 Gb/s Fibre Channel |
AB379B
|
PCI-X
|
Yes
|
LC
|
1
|
|
| PCIe 1 port 4 Gb/s Fibre Channel |
AE311A
|
PCIe
|
Yes
|
LC
|
2
|
|
| PCIe 2 port 4 Gb/s Fibre Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
2
|
|
| PCI-X 1 port 4 GB/s Fibre Channel |
AD167A
|
PCI-X
|
Yes
|
LC
|
1
|
|
| PCI-X 2 port 4 GB/s Fibre Channel |
AD168A
|
PCI-X
|
Yes
|
LC
|
1
|
|
| PCIe 2 port 4 Gb/s Emulex Fibre Channel |
A8003A
|
PCIe
|
Yes
|
LC
|
2
|
|
| PCIe 1 port 4 Gb/s Emulex Fibre Channel |
A8002A
|
PCIe
|
Yes
|
LC
|
2
|
|
| PCI 2 channel Ultra320 SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
1
|
|
| HP PCIe SC44Ge SAS HBA |
AH303A
|
PCIe
|
No
|
2
|
||
| 512 MB cache memory upgrade for SA P600 controller | 372538-B21 | PCI-X | N/A | N/A | N/A | |
| PCIe Smart Array P800 | AD335A | PCIe | Yes | Mini SAS | 2 | Only 1 will be factory integrated. |
| PCIe Smart Array P500 | AH226A | PCIe | Yes | Mini SAS | 2 | |
| Local Area Network (LAN) Adapters | ||||||
| PCIe 4-Gb Fibre Channel/GbE-T HBA combo | AD221A | PCIe | Yes | 2 | ||
| PCIe 2-port 4-Gb Fibre Channel/2-port GbE-T HBA combo | AD222A | PCIe | Yes | 2 | ||
| PCIe 2-port 4-Gb Fibre Channel/2-port GbE-SX HBA combo | AD393A | PCIe | Yes | 2 | ||
| HP PCI-X 2-port 1000Base-SX (optical) Gigabit Adapter |
A7011A
|
PCI-X
|
Yes
|
1
|
|
|
| PCI 2 port 1000Base TX |
A9900A
|
PCI-X
|
Yes
|
RJ-45
|
1
|
|
| HP PCI-X 266MHz 10GigE SR Card | AD385A | PCI-X | Yes | 1 | ||
| HP PCIe 2 port 1000Base T card | AD337A | PCIe | Yes | RJ-45 | 2 | |
| HP PCIe 2 port 1000Base SX card | AD338A | PCIe | Yes | Duplex SC | 2 | |
| For Infiniband support with Linux, please see the HPC Cluster Platform 6000 at www.hp.com/go/hptc. |
| * Boot from external storage only. |
|
|
| HP Integrity rx2660 OpenVMS Supported I/O Cards |
| I/O Card |
Product Number
|
PCIe/
PCI-X |
Boot Support
|
Connector Type(s)
|
Maximum Cards
|
Special Notes
|
| Mass Storage Host Bus Adapters | ||||||
| HP PCIe 1 port 4 Gb/s Fibre Channel HBA |
AD299A
|
PCIe
|
Yes
|
LC
|
2
|
|
| HP PCIe 2 port 4 Gb/s Fibre Channel HBA |
AD355A
|
PCIe
|
Yes
|
LC
|
2
|
|
| PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel |
AB378B
|
PCI-X
|
Yes
|
LC
|
3
|
|
| PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel |
AB379B
|
PCI-X
|
Yes
|
LC
|
3
|
|
| PCIe 2 port 4 Gb/s Fibre Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
2
|
|
| PCI 2 channel Ultra320 SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
3
|
|
| HP PCIe SC44Ge SAS HBA |
AH303A
|
PCIe
|
Yes
|
2
|
|
|
| PCI-X 2 channel Smart Array 6402 Ultra320 |
A9890A
|
PCI-X
|
Yes
|
VHDCI
|
2
|
|
| PCI-X 4 channel Smart Array 6404 Ultra320 |
A9891A
|
PCI-X
|
Yes
|
VHDCI
|
1
|
|
| PCIe Smart Array P800 | AD335A | PCIe | Yes | Mini SAS | 2 | |
| Local Area Network (LAN) Adapters | ||||||
| PCI-X 1 port 1000Base T |
AD331A
|
PCI-X
|
Yes
|
RJ-45
|
3
|
|
| PCI-X 1-port 1000Base-SX |
AD332A
|
PCI-X
|
Yes
|
LC
|
3
|
|
| PCI-X 2 port 1000Base SX |
A7011A
|
PCI-X
|
Yes
|
Duplex SC
|
3
|
|
| PCI-X 2 port 1000Base T |
A7012A
|
PCI-X
|
Yes
|
RJ-45
|
3
|
|
| PCI-X 4 port 1000Base T Gbit Adapter |
AB545A
|
PCI-X
|
Yes
|
RJ-45
|
2
|
|
| HP PCI-X 266MHz 10GigE SR Card |
AD385A
|
PCI-X
|
Yes
|
2
|
||
| HP PCIe 2 port 1000Base T card |
AD337A
|
PCIe
|
Yes
|
RJ-45
|
2
|
|
| HP PCIe 2 port 1000Base SX card | AD338A | PCIe | Yes | Duplex SC | 2 | |
| PCIe 4 port HP NC364T Gbit Adapter | AD339A | PCIe | Yes | 2 | ||
| Multi-Function Cards (Mass Storage/LAN) | ||||||
| PCI-X 2 port 1000Base T/2 port Ultra320 SCSI Multi function Adapter |
AB290A
|
PCI-X
|
Yes
|
SCSI - LVD/SE
LAN - RJ-45 |
2
|
SCSI bootable
|
| PCI-X 2 Gb Fibre Channel/1000Base SX |
A9782A
|
PCI-X
|
Yes
|
LC |
3
|
FC bootable
|
| HP PCI-X 1 port 4 Gb Fibre Channel and 1 port 1000Base T Adapter |
AD193A
|
PCI-X
|
Yes
|
(1) LC, (1) RJ-45
|
2
|
FC bootable
|
| HP PCI-X 2 port 4 Gb Fibre Channel and 2 port 1000Base T Adapter |
AD194A
|
PCI-X
|
Yes
|
(2) LC, (2) RJ-45
|
2
|
FC bootable |
| HP PCIe 1-port 4Gb Fibre Channel
and 1-port 1000BaseT Adapter |
AD221A | PCIe |
Yes
|
2
|
||
| HP PCIe 2-port 4Gb Fibre Channel
and 2-port 1000BaseT Adapter |
AD222A | PCIe |
Yes
|
2
|
||
| HP PCIe 2-port 4Gb Fibre Channel and 2-port 1000BaseT Adapter | AD393A | PCIe |
Yes
|
2
|
||
| Additional Interface Cards | ||||||
| HP 2D PCI-X graphics card | AH391A | PCI-X | No | PCI-X only backplane:
2 Combo backplane: 1 |
AH391A offers 2D graphics support. Support available for OpenVMS | |
|
|
|
||||||||||||||||
| HP USB Options |
HP Integrity USB External DVD-RW drive |
AT120A |
| NOTE:
The HP Integrity USB External DVD-RW drive solution includes the External
DVD drive (AT120A) with 9 inch USB cable, power adaptor, power cable and
Y connector and 7-foot USB extension cable. NOTE: The USB Y-connector goes between the extension cable and the 9-inch USB cable fixed with DVD drive. NOTE: The Y-connector should NOT be placed between the server blade and the 7 foot Extension cable. NOTE: The External USB drive(AT120A) comes box-packed and is not factory integrated with the server. NOTE: If the External USB drive(AT120A) is ordered along with the server, the order needs to be allowed to ship from different locations. |
||
|
|
||
| Integrated Multi-function Core I/O | The integrated multi function I/O provides core I/O functionally and includes the management processor, which provides remote management and high availability monitoring capabilities. |
| | |
| Core I/O |
|
| | |
| Integrity Integrated Lights Out (iLO2) Management Processor Functionality |
Supported resolutions and refresh rates include: |
||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||
| System Console Configurations |
The HP Integrity rx2660's integrated iLO2 Management Processor provides
six methods for console connections.
|
| | |
| Internal Disk and Media Drives |
|
|
| |
| HP Integrity Trusted Platform Module | The rx2660 has an accessory option
for an embedded security chip - the Trusted Platforms Module (TPM) - product
number AB404A. HP-UX Trusted Computing Services (HP-UX TCS) provides software
support for the TPM when running HP-UX 11i v2. By providing a low-cost embedded
security chip option (known as a Trusted Platform Module) in its zx2-based
Integrity servers (rx2660, rx3600, and rx6600), HP has established a foundation
for strong protection of sensitive information - including cryptographic
keys. Built around industry standards, the Trusted Platform Module (TPM)
provides a basis for key storage by securely generating and storing cryptographic
keys. HP-UX 11i TCS takes this a step further by providing the necessary
infrastructure for managing the TPM, as well as integrating it into select
features such as HP-UX Encrypted Volumes and File Systems (EVFS).
Using HP-UX TCS with EVFS: Using HP-UX TCS to make the unattended boot capability of EVFS more secure is an important example of how HP-UX TCS can be integrated with other applications to enhance security. For more information see the "Protecting EVFS Keys with HP-UX TCS" chapter in the "HP-UX Trusted Computing Services Administrators Guide" available in the HP-UX Trusted Computing Services section at: http://docs.hp.com/en/internet.html Please note that HP-UX 11iTCS requires: (1) An HP zx2-based Integrity server (rx2660, rx3600, or rx6600) with
a TPM installed, running HP-UX 11iv2 September 2006 release or later |
| | |
| HP Integrity rx2660 Power Subsystem |
The HP Integrity rx2660 provides a high level of integrated power protection:
The HP Integrity rx2660 supports a second hot swap power supply for N+1 protection. One power supply is shipped as a standard part of every system and is required for correct operation. The hot swap design allows for the online replacement of a power supply when N+1=2 supplies are configured in the server. The HP Integrity rx2660 provides an independent power input receptacle for each power supply (c13/C14 type). The independent design provides protection against losing the connection from a power cord or breaker. The HP Integrity rx2660 power cords should always be plugged into separate breakers whenever possible. |
|
|
Technical Specifications
| Server model number | rx2660 | |
|
|
||
| Server product numbers | 2 processor/4 core capable HP Integrity rx2660 server base system with two processor modules: |
AH235A |
| Configure with two 1.6 GHz/12 MB single core 9110N processor modules |
001 | |
| Configure with two 1.42 GHz/12 MB dual core 9120N processor modules |
002 | |
| Configure with two 1.66 GHz/18 MB dual core 9140M processor modules |
003 | |
| In
addition to two processor modules, the base system includes one power supply (second
supply can be added for redundancy-AD254A), 2×10/100/1000 GbE ports (supports
Wake On LAN), and 8 port SAS controller. Must select I/O backplane (1 maximum)and
a minimum of 2 GB memory. Disk drive must be added for a complete hardware solution. | ||
| OFS - Configure with two 1.6 GHz/12 MB single core 9110N processor modules |
004 | |
| OFS - Configure with two 1.42 GHz/12 MB dual core 9120N processor modules |
005 | |
| OFS - Configure with two 1.66 GHz/18 MB dual core 9140M processor modules |
006 | |
| Server
From Factor (Required - Must choose either Factory Rack Integration or Field
Rack Kit) Please refer to the HP 10000 Series G2 Rack Best Practices Guide for information on rack deployment, stabilization and transportation (http://www.HP.com/go/rackandpower) | ||
| Universal Rack Kit | AD253A | |
| Field Rack Kit |
B01 | |
| Includes rails and cable management arm. | ||
| Factory Rack Integration | B01 | |
| For factory rack integration, a rack cabinet must appear in the same section of the order. The slides and cable management arm will be installed with the server in the rack cabinet when factory rack integration is ordered. | ||
| Pedestal Kit |
AD251A | |
| Racking Support Shelf Kit. Required for all factory racked orders. One shelf kit is needed for every 10 servers in the rack and one for every gap left between servers. |
AB469A | |
| NOTE:
If the N+1 power supply is ordered standalone the power supply will ship with
two cords;; one connects the system to the rack PDU and one enables connection
to a wall socket. The cord that connects the system power supply to the PDU has
an IEC 13 end, which plugs into the system power supply's IEC 14 socket, and an
IEC 14 end, which plugs into the PDU's IEC 13 socket. The localized cord that
connects the system power supply directly to the wall socket has an IEC 13 end,
which plugs into the system power supply's IEC 14 socket, and a country specific
end, which plus into the wall socket. This localized cord is included at the distribution
site. If the N+1 power supply is ordered with the server, the additional cords will be included. | ||
|
| ||
| Supported Processors
for Field Upgrades NOTE: Processor frequencies cannot be mixed within a system. |
1.6 GHz Single core Intel Itanium Processor (AD392A) | |
| Cache - On chip Level 1 | 32-KB | |
| Cache - On-Chip Level 2 | 1-MB Instruction/256-KB Data | |
| Cache - On-Chip Level 3 | 12-MB | |
| Floating point Coprocessor included | Yes | |
| 1.4 GHz Dual core Intel Itanium Processor (AH240A) | ||
| Cache - On chip Level 1 | 32 KB | |
| Cache - On-Chip Level 2 | 1 MB instruction/256 KB Data (per core) | |
| Cache - On-Chip Level 3 | 12 MB (6 MB per core) | |
| Floating point Coprocessor included | Yes | |
| 1.6 GHz Dual core Intel Itanium Processor (AH241A) | ||
| Cache - On chip Level 1 | 32 KB | |
| Cache - On-Chip Level 2 | 1 MB instruction/256 KB Data (per core) | |
| Cache - On-Chip Level 3 | 18 MB (9 MB per core) | |
| Floating point Coprocessor included | Yes | |
|
|
||
| System Memory | Minimum memory | 2 GB |
| Maximum memory capacity (8x 4GB DIMMs) | 32 GB | |
|
|
||
| Internal Disks | Maximum disk mechanisms | 8 |
| Maximum disk capacity | 2,400 GB | |
|
|
||
| Standard Integrated I/O | Serial Attached SCSI (SAS) | 8 ports |
| 10/100/1000Base-T (RJ 45 connector) | 2 port | |
| RS-232 serial port (general purpose) | 1 | |
| RS-232 serial port (management processor) | 1 | |
| 10/100Base-T management port (RJ 45 connector) | Included | |
| VGA graphics | 1 front/1 rear | |
| USB | 1 front/2 rear | |
|
|
||
| I/O Buses and Slots (Must select 1 only) | PCI-X 3 slot card cage (2×266 MHz/64 bit slots, and 1×133 MHz/64 bit slot) |
AD246A*
|
| PCI-X/PCI Express combo card cage (2×Express slots with 4×333 MHz ropes, and 1×133 MHz/64 bit PCI-X) |
AD247A**
|
|
| *Not
supported with Windows based systems. **Required for Windows based systems. Optional for HP UX , Linux- and OpenVMS based systems. |
||
|
|
||
| Maximum I/O Cards (See supported I/O table for product specifics) |
Mass Storage | 3 |
| LAN | 3 | |
| WAN | 3 | |
| Multi-Function (Mass Storage / LAN) | 3 | |
| Additional Interface Cards | 3 | |
|
|
||
| Electrical Characteristics | AC Input power | 100-240V 50/60 Hz |
| Hot swap Power supplies | 1 included, 2nd for N+1 | |
| Redundant AC power inputs | 1 included, 2nd for N+1 | |
| Maximum input power (for maximum processor, memory, disk, DVD, I/O configurations) | 798W 2,724 BTU/hour |
|
| Input Power at Idle (for maximum processor,
memory, disk, DVD, I/O configurations) |
567W 1,936 BTU/hour |
|
| Maximum input current | 10A @ 100 Vms or 7A @ 200 Vms | |
| Power factor at full load | 0.98 (approximately) | |
|
|
||
| Site Preparation | Site planning and installation included NOTE: System is customer installable. |
No |
| Rack depth (inches/mm) | 26.8 in (680 mm) | |
| Rack width (inches/mm) | 19 in (482 mm) | |
| Rack height (EIA/inches/mm) | 2U/ 3.4 in (86 mm) | |
| Rack weight (kg/lbs) maximum | 61.6 lbs. (28 kg) | |
|
|
||
| Environmental Characteristics | Regulatory Model | RSVL 0503 |
| Acoustics (operator/bystander) at 77° F (25° C) | 7.0 Bels LwA | |
| Operating Temperature (up to 5000 ft/1524 m)* |
41° to 95° F (5° to 35° C) | |
| Non-operating Temperature | 5° to 35° F (-40° to 70° C) | |
| Maximum rate of temperature change | 20° C/hour | |
| Operating relative humidity | 15% to 80% RH non-condensing | |
| Non-operating relative humidity | 8% to 85% non-condensing | |
| Operating altitude above sea level | 10,000 ft (3,000 m) maximum | |
| Non-operating altitude above sea level | 15,000 ft (4,600 m) maximum | |
| * Maximum operating temperature range up to 5000 feet. For higher altitudes, de-rate the maximum temperature by 2°C/1000 feet above 5000 feet. | ||
|
|
||
| Regulatory Compliance | Regulatory Model Number | RSVLA-0503 |
| Electromagnetic interference | Complies with FCC Rules and Regulations, Part 15, as a Class A digital device. Manufacturer's Declaration to EN55022 Level A, VCCI Registered, Class 1, Korea RLL, BMSI Taiwan | |
| Safety | UL Listed, CSA Certified, TUV
GS Mark compliant with EN 60950 and EN 41003 |
|
| More detailed regulatory documents and certifications | http://docs.hp.com/en/hw.html | |
|
|
||
| © Copyright 2012 Hewlett-Packard
Development Company, L.P.
The information contained herein is subject to change without notice. Intel and Itanium are registered trademarks or trademarks of Intel Corporation in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |