 Overview      Standard Features      Configuration      Technical Specifications line.gif (50 bytes)

Overview

HP Integrity rx2660 Server

HP Integrity rx2660 System Overview (Top View)
1.6 pairs redundant system fans (3 cooling zones) 5.3-slot I/O cage 3 PCI-x or 2 PCI-e; 1 PCI-x
2.8x DIMM slots6.CPUs
3.N+1 power supplies7.HDD cage
4.HP 8-port Smart Array SAS Controller (optional)  

At A Glance
Standard System Features
  • Four Operating System support: HP UX 11i version 2 (September 2006 Update required for dual core processors); HP-UX 11i version 3; Windows Server 2003 Enterprise Edition; Linux RHEL 4 U4 AS and ES, and SLES 10; OpenVMS (V8.3 minimum version required)
  • Core 8 port Serial Attached SCSI (SAS) host bus adapter, supports up to two internal RAID 1 volumes (2×2 HDDs) and a disk for global hot spare, for a maximum of five disks in RAIDed arrays for HP UX, OpenVMS, and Linux. The additional three drives (of the maximum of eight drives supported) can be accessed normally, but not configured for RAID. Factory set up of RAID 1 is supported. Please see rx2660 Ordering Guide for details. HP/UX Mirroring is available for all HDDs in HP UX based systems and HP Volume Shadowing Level 1 is available for HDDs in OpenVMS based systems. Windows does not support the embedded 8 port SAS host bus adapter. Windows based customers must select the 8 port Smart Array P400 Serial Attached SCSI (SAS) controller, supports internal RAID 1, 5 and 6 configurations. The 8 port Smart Array P400 Serial Attached SCSI (SAS) controller is supported by HP UX, OpenVMS, and Linux as an optional add on.
  • Core dual port 10/100/1000Base TX LAN (with auto speed sensing; RJ 45 connector, Wake On LAN support)
  • Integrated iLO2 Management Processor for remote management and HA monitoring
  • Telnet and web console via 10/100Base TX management LAN (RJ 45 connector)
  • Two RS 232 serial ports, one for console from the integrated iLO2 management processor and one from the processor dependent hardware bus (PDH)
  • Factory integration of processors, memory, disk drives, removable media, I/O cards, and HP Universal 10000 G2 series racks.
  • Rackmountable into 19 inch cabinets-HP Universal 10000 Series G2 racks as well as many third party racks, including field integration into existing HP System E racks
  • Optional stand alone pedestal mount
  • Three year warranty with next business day on site
contents
 Overview      Standard Features      Configuration      Technical Specifications line.gif (50 bytes)

Standard Features

Minimum System
  • One 64 bit Intel Itanium processor: Either dual core 1.6 GHz/18 MB L3 cache (533 MHz front side bus), dual core 1.4 GHz/12 MB L3 cache (533 MHz front side bus), or single core 1.6 GHz/6.0 MB L3 cache (533 MHz front side bus); or dual core 1.66 GHz/18 MB 9140M processor with L3 cache (667 MHz front side bus), dual core 1.42 GHz/12 MB 9120N processor with L3 cache (533 MHz front side bus), or single core 1.6 GHz/12.0 MB 9110N processor with L3 cache (533 MHz front side bus).
  • One I/O card cage. Either all PCI X card cage (two 266 MHz/64 bit slots and one 133 MHz/64 bit slot) or Combo I/O card cage (two PCI Express slots with 4×333 MHz ropes and one 133 MHz PCI X slot). Windows systems must order the Combo (PCI Express and PC X) I/O card cage. The PCI X only card cage is not supported with Windows.
  • 2 GB PC2 4200 x4 single rank Registered DDR2 SDRAMs (2×1GB DIMMs)
  • Eight DIMM slots
  • One hot swap power supply

Maximum Server Capacities
  • Two 64 bit Intel Itanium processors: Dual core 1.66 GHz/18 MB 9140M processor with L3 cache (667 MHz front side bus), dual core 1.42 GHz/12 MB 9120N processor with L3 cache (533 MHz front side bus), or single core 1.6 GHz/12.0 MB 9110N processor with L3 cache (533 MHz front side bus).
  • 32 GB PC2 4200 x4 single-rank Registered DDR2 SDRAMs (8×4 GB DIMMs)
  • Eight DIMM slots
  • Two hot swap power supplies, providing N+1 protection for power supplies and power input
  • Three IO adapter cards
  • One internal DVD ROM or DVD+RW drive (DVD+RW not supported on HP UX)
  • Eight internal hot plug Serial Attached SCSI (SAS) disks

Standard System Features
  • Four Operating System support: HP UX 11i version 2 (September 2006 Update required for dual core processors); HP UX 11i version 3; Linux RHEL 4 U4 AS and ES, and SLES 10; OpenVMS (V8.3 minimum version required); and Microsoft Windows Server 2003 Enterprise and Datacenter Edition, Microsoft Windows Server 2008 for Itanium-based Systems, and Microsoft SQL Server 2005 and SQL Server 2008
  • Two Core IO Serial Attached SCSI (SAS) options, an embedded 8P SAS controller, and an optional 8 port Smart Array P400 SAS host bus adapter. Windows only supports the 8 port Smart Array P400 SAS host bus adapter.
  • Core dual port 10/100/1000Base TX LAN (with auto speed sensing; RJ 45 connector, Wake On LAN support).
  • Integrated iLO2 Management Processor for remote management and HA monitoring.
  • Telnet and web console via 10/100Base TX management LAN (RJ 45 connector).
  • Two RS 232 serial ports, one for console from the integrated iLO2 management processor and one from the processor dependent hardware bus (PDH).
  • Factory integration of processors, memory, disk drives, removable media, I/O cards, and HP Universal 10000 G2 series racks.
  • Rackmountable into 19 inch cabinets-HP Universal 10000 Series G2 racks as well as many third party racks, including field integration into existing HP System E racks.
  • Optional stand alone pedestal mount.
  • Three year warranty with next business day on site.

High Availability
  • N+1 Hot swap cooling (not available with OFS [Office Friendly Server) system]
  • One Hot swap power supply standard-optional second hot swap power supply for N+1 protection (two included in OFS systems for reduction of acoustics
  • On line memory page deallocation
  • ECC protected DDR2 memory
  • Memory double chip spare to overcome single DRAM chip failures
  • Dynamic Processor resilience and deallocation
  • UPS power management
  • Hot Plug internal disks
  • Two Core IO Serial Attached SCSI (SAS) options, an integrated 8P SAS controller, and an optional 8 port Smart Array P400 SAS host bus adapter which comes with battery backed write cache (BBWC) and 256MB of memory. Windows only supports the 8 port Smart Array P400 SAS host bus adapter. When ordered the optional 8 port Smart Array P400 SAS host bus adapter is located in a 'private' slot and does use one of the system PCI slots. A maximum of (1) Core IO SAS controller connected to the embedded HDD's is supported on the rx2660 server.
  • Journal file system with HP UX
  • Auto reboot
  • HP Serviceguard for HP UX
  • HP Serviceguard Extension for RAC for HP UX
  • HP Serviceguard Extension for SAP for HP UX
  • Serviceguard Manager for HP UX and Linux Clusters
  • HP Event Monitoring Service
  • HA Monitors for HP UX
  • HA Toolkits for HP UX and Linux
  • HP Mirrordisk/UX
  • Extended Campus Cluster, HP Metrocluster, and HP Continentalclusters for HP UX
  • HP OpenVMS clusters
  • HP Volume Shadowing for OpenVMS
  • HP RMS Journaling for OpenVMS
  • HP System Insight Manager (SIM) for proactive fault management
  • Microsoft Cluster Service for Windows Server 2003 Enterprise and Datacenter Editions
  • HP StorageWorks Software for HP Integrity Servers running Windows Server 2003 Enterprise and Datacenter Editions. Includes Cluster Extension XP and EVA, Continuous Access, Business Copy and SQL Server Fast Recovery, and Storage Mirroring
  • HP StorageWorks Cluster Extension XP for Linux

Security
  • TPM (Trusted Platforms Module) option available
  • Separate LAN for system management
  • Password protection on console port
  • Disablement of remote console ports
  • SSL encryption on web console

Manageability-Monitor
  • Built-in Integrity iLO 2 Management Processor for comprehensive remote server management of HP-UX, Linux, Windows and OpenVMS
  • Integrity iLO 2 Advanced Pack for Virtual Media (CD, DVD, and ISO image) support of HP-UX, Windows and Linux, and Virtual KVM support of Windows
  • HP System Insight Manager (SIM)
  • HP Servicecontrol suite for HP-UX servers including tools for system administration, asset management, and fault management
  • HP-UX kernel configuration for easy, dynamic kernel parameter changes

Manageability-Optimize
  • Process Resource Manager for HP-UX resource management
  • HP UX Workload Manager for HP-UX workload management based upon service level objectives
  • HP OpenView GlancePlus Pack
  • HP Intelligent Networking Pack for Windows
  • Remote Direct Memory Access (RDMA) pack for Windows
  • HP Performance Management Pack for Windows
  • Windows System Resource Manager (included with each copy of Windows Server 2003 Enterprise Edition)

Manageability-Deployment
  • HP Rapid Deployment Pack for Windows and Linux
contents
 Overview      Standard Features      Configuration      Technical Specifications line.gif (50 bytes)

Configuration

Processor Configuration The HP Integrity rx2660 is a symmetrical multiprocessing (SMP) server supporting up to two high performance 64 bit Itanium processors. Processor speeds cannot be mixed within the same system.

Processor Details

Single core Itanium processors:

  • Single core 1.6 GHz with 6.0 MB Level 3 Cache processor (Upgrade Only)
  • Single-core 1.6-GHz with 12.0-MB Level 3 Cache 9110N processor

Dual core Itanium processor:

  • Dual core 1.4 GHz with 12 MB (6 MB per core) Level 3 Cache processor (Upgrade Only)
  • Dual core 1.42 GHz with 12 MB (6 MB per core) Level 3 Cache 9120N processor
  • Dual core 1.6 GHz with 18 MB (9 MB per core) Level 3 Cache processor (Upgrade Only)
  • Dual core 1.66 GHz with 18 MB (9 MB per core) Level 3 Cache 9140M processor

All processors support:

  • Level 2 Cache: 1 MB Instruction/256 KB Data per core
  • Level 1 Cache: 32 KB per core
  • 400 MHz System Bus
  • Single bit cache error correction
  • 50 bit physical addressing
  • 64 bit virtual addressing
  • 4 GB maximum page size

Memory Configuration The HP Integrity rx2660 supports DDR (double data rate) SyncDRAM (synchronous dynamic random access memory) DIMMs with ECC and chip spare protection. The HP Integrity rx2660 has eight DIMM slots. A maximum of 32 GB is supported (8×4GB DIMMs).
Memory Loading Rules and Performance Guidelines
  • Memory must be installed in groups of two DIMMs, also known as pairs or modules
  • Each memory pair must consist of DIMMs of the same type: same capacity/density, same organization, same number of ranks, and same speed
  • Memory be ordered in modules (pairs) of 2 GB (2×1GB), 4 GB (2×2GB), or 8 GB (2×4GB)
  • Minimum memory is 2 GB (2×1GB). NOTE: 2-GB is required for HP-UX 11i v3.
  • Maximum memory is 32-GB, using four 8 GB (2×4GB) memory pairs
  • Arrange DIMMs so that the pairs with the largest capacity are in the lowest numbered slots
  • For best performance, all DIMM slots should be populated with the same size DIMM.
 
Supported Memory Options
Description Product Number
2-GB chip spare PC2 4200 ECC x4 single rank Registered DDR2 SDRAM memory pair (2×1 GB DIMMs) AD274A
4-GB chip spare PC2 4200 ECC x4 single rank Registered DDR2 SDRAM memory pair (2×2 GB DIMMs) AD275A
8-GB chip spare PC2 4200 ECC x4 single rank Registered DDR2 SDRAM memory pair (2×4 GB DIMMs) AD276A

Server Form Factors and Rack Configuration The HP Integrity rx2660 is a 2U server. It comes in 3 form factors: rack mounted, OFS (Office Friendly Server) and pedestal versions. The rack mounted and OFS versions have the same base model product numbers with different options. The rack mounted versions are AH234A and AH235A options 001-003; the OFS are AH234A and AH235A options 004-006

The OFS is a pedestal form factor with reduced acoustics for workstation replacement and/or office environments. Note that the OFS does not support redundant fans or redundant power.

Please note that the pedestal version is not factory installed-it is a kit (AD251A) that must be assembled on site.

The rack mounted version of the rx2660 is supported in HP 10000 Series G2 cabinets. For factory integration order the Universal Rack Kit, AD253A, with 0D1 feature code. Sliding mounts and a cable management arm will be installed with the server in a factory integrated rack.

The HP Integrity rx2660 can be installed in the field with the Universal Rack Kit (AD253A with B01 feature code). This kit contains the slide mounts, cable management arm, and all other hardware needed to mount an rx2660 into a 19 inch cabinet.

Refer to the 10000 Series G2 Rack Best Practices Guide for information on rack deployment, stabilization, and transportation. Go to http://www.hp.com/go/rackandpower for more information.


Non-HP Cabinets For customers who choose to use non HP cabinets, the HP Integrity rx2660 provides simple options for installation and HP field support. The HP Integrity rx2660 field rack kit (AD253A) contains adjustable slide rails, allowing the server to be mounted in cabinets that use the four post EIA mounting system.

 

Once the server is mounted in a non HP cabinet, it must meet some simple criteria to ensure that HP field personnel can fully support the rack environment.

  • Anti Tip-The rack/cabinet must be solidly anchored to the floor both front and rear. This is usually accomplished by anti tip feet or by direct bolting to the floor.
  • Air Flow-The HP Integrity rx2660 uses front to back airflow to cool the unit. Thus a cabinet cannot have a solid front or rear door. Solid doors may have to be removed or changed to an open perforation pattern.
  • Cable Strain Relief-A proper method of strain relief must be used. This may force the elimination of the rear door in some cases.
  • Front and Rear Access-For proper cooling and ease of service access, HP recommends 32 inches of unobstructed floor space in the front and rear of rack installations. This recommendation applies to both HP and third party racks and cabinets.

I/O Architecture
The HP Integrity rx2660 I/O architecture utilizes industry standard PCI X and PCI Express buses in a unique design for maximum flexibility, I/O card availability, performance, scalability, and reliability.

The HP Integrity rx2660 I/O architecture consists of six dedicated I/O channels which provide up to 8.2 GB/s of I/O bandwidth allocated across standard I/O connectivity (with the Combo I/O backplane option), a dedicated slot for an optional 8 port Smart Array P400 Serial Attached SCSI (SAS) controller (mandatory with Windows based systems) and three open slots for additional, optional I/O card choices. The diagrams above show how these channels allocate bandwidth to the open I/O slots and to the integrated core I/O.

The standard I/O connectivity is integrated on the rx2660 system board and includes an integrated HP 8 Internal Port SAS (Serially Attached SCSI) Host Bus Adapter, two 1000Base TX LAN ports, an RN50 graphics port, three USB v2.0 ports, and one general RS 232 Serial Port. Additionally, there is a standard Integrity iLO2 Management Processor with a rear RS 232 Serial Port.

Each port of SAS Host Bus Adapter can be connected to a SAS hard disk drive. SAS is a point to point architecture, compared to Ultra320 SCSI which is a bus based architecture. With SAS, each disk has its own individual 3 GB link. NOTE: That there are two possible 'integrated' RAID controllers for the rx2660: AD248A #106 refers to the embedded SAS RAID controller. AD248A #130, 530 and 540 refers to an add-in SAS p400 Smart Array card which occupies a 'private' slot (does not use one of the system's PCI slots).

HP UX, OpenVMS, and Linux support the integrated HP 8 Internal Serial Attached SCSI host bus adapter (AD248A #106), which supports a maximum of two RAID 1 volumes (2×2 HDDs) and a disk for global hotspare, for a maximum of five disks in RAIDed arrays. The remaining three disks (of the maximum eight disks that are supported) can be accessed normally, but not configured for RAID. Please note that MirrorDisk/UX is available for software mirroring on all HDDs in HP UX based systems, as HP Volume Shadowing (software Raid 1) for HDDs in OpenVMS based systems. Windows does not support this integrated HP 8 Internal Port SAS Host Bus Adapter. All Windows systems must order the HP 8 Port SAS Smart Array P400 Serial Attached SCSI (SAS) Controller Card (AD248A #130, 530, and 540), which is also available as an optional choice for HP UX, OpenVMS, and Linux systems. The HP 8 Port SAS Smart Array P400 Serial Attached SCSI (SAS) Controller is accommodated via a dedicated PCI Express slot, which provides up to 1.3 GB/s of sustained bandwidth.

The HP 8 Port SAS Smart Array P400 Serial Attached SCSI (SAS) Controller Card supports RAID 1, 5 and 6. All eight disks can be configured with this card for RAID 1, 5 and 6 in any combination. RAID 1 requires two identical HDDs, RAID 5 requires three identical HDDs, and RAID 6 requires four identical HDDs. Factory configuration of a RAID set is available. Please see rx2660 Ordering Guide for details. The two standard 1000Base TX LAN ports support Wake On LAN.

There is a mandatory choice of only one of two internal I/O card cage options, each option provides three I/O slots for I/O expansion within the system enclosure. The two I/O card cage options are an all PCI X Card Cage and a Combo Card Cage. The all PCI X Card Cage provides two PCI X 266 MHz 64 bit I/O slots and one PCI X 133 MHz 64 bit I/O slots (AD246A). Please note that this option (AD246A) is not supported with Windows based systems. Each slot of the AD246A has its own dedicated bus and its own independent I/O channel. An independent channel provides improved I/O performance and error containment. Independence protects each I/O card from bus hangs or extended latencies due to the failure or high bandwidth demands of other I/O cards. Independence also ensures that each I/O card can achieve maximum throughput. The two 266 MHz slots provide 2.1 GB/s of sustained bandwidth, while the one 133 MHz slot provides 1.1/GB/s of sustained bandwidth.

The Combination Card Cage (AD247A) provides two PCI Express x8 slots and one PCI X 133 MHz 64 bit I/O slot. Please note that the AD247A is required for Windows based systems. Each slot of the AD247A has its own dedicated bus and its own independent I/O channel. The two PCI Express slots 2.6 GB/s of sustained bandwidth, while the one 133 MHz slot provides 1.1 GB/s of sustained bandwidth.

All I/O slots are keyed for 3.3V I/O cards. 5V cards are not supported in the HP Integrity rx2660. OLAR (On-line add/remove) operations are not supported on the rx2660.

The chart below provides further details on the standard I/O.

 
    Bandwidth Bus Width Bus Speed Slot Keying
HP 8 Internal Port SAS Host Bus Adapter Core I/O. Supports up to 8 Internal SAS Disk Drives.
NOTE: Not supported on Windows-based servers.
Integrated on System Board 512 MB/s, shared with 1000Base TX LAN Core I/O 64 bits 66 MHz 3.3 Volts
1000Base TX LAN Core I/O. Integrated on System Board 512 MB/s, shared with HP 8 Internal Port SAS Host Bus Adapter Core I/O. 64 bits 66 MHz 3.3 Volts
RN50 Graphics (front or rear connection), 3 USB Ports (1 front, 2 rear), RS 232 General Serial Port Integrated on System Board 133 MB/s, shared among all functions 32 bits 33 MHz 3.3 Volts
Integrity iLO2 Management Processor, 1 rear RS 232 Serial Port Integrated on System Board        
Optional HP 8 Port SAS Smart Array P400 Serial Attached SCSI (SAS) Controller Card
NOTE: This card is mandatory for Windows-based systems.
Private Slot 1.3 GB/s 64 bits   3.3 Volts

HP Integrity rx2660 HP-UX 11i Supported I/O Cards
I/O Card
Product Number
PCIe/
PCI-X
Boot Support
Connector Type(s)
Maximum Cards
Special Notes
Mass Storage Host Bus Adapters
PCIe 4Gb Fibre Channel / GbE-T HBA combo
AD221A
PCIe
Yes
2
Only HP-UX v3 is supported today
PCIe 2-port 4Gb Fibre Channel / 2-port GbE-T HBA combo
AD222A
PCIe
Yes
2
Only HP-UX v3 is supported today
PCIe 2-port 4Gb Fibre Channel / 2-port GbE-SX HBA combo
AD393A
PCIe
Yes
2
Only HP-UX v3 is supported today
HP PCIe 1 port 4 Gb/s Fibre Channel HBA
AD299A
PCIe
No
LC
2
 
HP PCIe 2 port 4 Gb/s Fibre Channel HBA
AD355A
PCIe
No
LC
2
 
PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel
AB378B
PCI-X
Yes
LC
1
 
PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel
AB379B
PCI-X
Yes
LC
3
PCIe 2 port 4 Gb/s Fibre Channel
AD300A
PCIe
Yes
LC
2
PCI 2 channel Ultra320 SCSI
A7173A
PCI-X
Yes
VHDCI
3
HP PCIe SC44Ge SAS HBA AH303A PCIe Yes   2  
PCI-X 2 channel Smart Array 6402 Ultra320 A9890A PCI-X Yes VHDCI 3  
PCI-X 4 channel Smart Array 6404 Ultra320 A9891A PCI-X Yes VHDCI 3  
PCIe Smart Array P800 AD335A PCIe No Mini SAS 2  
Local Area Network (LAN) Adapters
PCI-X 1-port 1000Base T
AD331A
PCI-X
No
RJ-45
3
 
PCI-X 1-port 1000Base SX
AD332A
PCI-X
No
LC
3
 
PCI-X 2 port 1000Base SX
A7011A
PCI-X
Yes
Duplex SC
3
 
PCI-X 2 port 1000Base T
A7012A
PCI-X
Yes
RJ-45
3
 
PCI-X 4-port 1000Base T Gbit Adapter
AB545A
PCI-X
Yes
RJ-45
3
 
PCI-X 1 port 10 GbE
AB287A
PCI-X
Yes
Duplex LC
3/1
3 for rack version; 1 for OFS
PCI-X 266 MHz 1 port 10 GbE AD385A PCI-X Yes Duplex LC 3/1 3 for rack version; 1 for OFS
HP PCIe 2 port 1000Base T card
AD337A
PCIe
Yes
RJ-45
2
HP PCIe 2 port 1000Base SX card
AD338A
PCIe
Yes
Duplex SC
2
PCIe 2 port 4X DDR Fast IB HCA
AH304A
PCIe
No
 
2
 
HP PCI e 10GbE SR card
AD386A
PCIe
Yes
2
 
PCIe 4 port HP NC364T Gbit Adapter
AD339A
PCIe
Yes
2
 
Wide Area Network (WAN) Adapters
2 port Programmable Serial Interface (PSI)
X.25/Frame Relay/SDLC

J3525A

PCI-X
No
RS 530, RS 232, V.35, RS 449 or X.21
3
 
Cluster Interconnect
PCI-X 2 port 4x Fabric (HPC) Adapter AB286C PCI-X No 4x Infiniband Copper 3  
PCIe 2 port 4x Fabric (HPC) Adapter AD313A PCIe No 4x Infiniband
Copper
2  
Multi function Cards (Mass Storage/LAN)
PCI-X 2 port 1000Base T/2 port Ultra320 SCSI Multi function Adapter AB290A PCI-X Yes SCSI - LVD/SE
LAN - RJ-45
3  
PCI-X 2 Gb Fibre Channel/1000Base SX A9782A PCI-X Yes LC 3  
HP PCI-X 1 port 4 Gb Fibre Channel and 1 port 1000Base T Adapter AD193A PCI-X Yes (1) LC, (1) RJ-45 3  
HP PCI-X 2 port 4 Gb Fibre Channel and 2 port 1000Base T Adapter AD194A PCI-X Yes (2) LC, (2) RJ-45 3  
Additional Interface Cards
PCI 8-port Serial MUX Adapter
AD278A
PCI-X
No
 
3
 
PCI 64-port Serial MUX Adapter
AD279A
PCI-X
No
 
3
 
16-port RS-232 RJ45 Port Module
AD280A
PCI-X
No
 
4 per AD279A

AD280A #001 Port Module Power Supply, required on Port Module (3) and Port Module (4) connected to an AD279A 64P MUX adapter.

16-port RS-232 DB25 Port Module
AD281A
PCI-X
No
 
4 per AD279A

AD281A #001 Port Module Power Supply, required on Port Module (3) and Port Module (4) connected to an AD279A 64P MUX adapter.

HP PCI Audio Card
AD317A
PCI-X
No
 
1
Factory Integration Only
HP 2D PCI-X graphics card AH391A PCI No VGA T/P/I: PCI-X 2/2/2, PCI-X/PCI e 1/1/1 AH391A offers 2D graphics support. Support available for HP UX v3 and v2; OpenVMS 8.3 1h1 and 8.3.
HP PCIe 1-port 8Gb FC SR (Qlogic) HBA AH400A PCIe Yes   2  
HP PCIe 2-port 8Gb FC SR (Qlogic) HBA AH401A PCIe Yes   2  

HP Integrity rx2660 Windows Server 2003 Supported I/O Cards
I/O Card
Product Number
PCIe/
PCI-X

Boot Support
Connector Type(s)
Maximum Cards
Special Notes
Mass Storage Host Bus Adapters
PCI-X 1 port 4 Gb/s Fibre Channel
AB429A
PCI-X
Yes 1
LC
1
 
PCI-X 266 MHz 2 port 4 Gb/s Fibre Channel
AB379B
PCI-X
Yes 1
LC
1
PCIe 1 port 4 Gb/s Fibre Channel
AE311A
PCIe
Yes 1
LC
2
 
PCI-X 1-port 4-GB/s Fibre Channel
AD300A
PCIe
Yes 1
LC
2
 
PCI-X 1 port 4 GB/s Fibre Channel
AD167A
PCI-X
Yes 1
LC
1
 
PCI-X 2 port 4 GB/s Fibre Channel
AD168A
PCI-X
Yes 1
LC
1
 
PCIe 2 port 4 Gb/s Emulex Fibre Channel
A8003A
PCIe
Yes 1
LC
2
 
PCIe 1 port 4 Gb/s Emulex Fibre Channel
A8002A
PCIe
Yes 1
LC
2
 
PCI 2 channel Ultra320 SCSI
A7173A
PCI-X
Yes
VHDCI
1
 
PCI-X Smart Array P600 Serial Attached SCSI (SAS) Controller
337972 B21
PCI-X
Yes
SFF8470
3
Only 2 will be factory integrated.
PCIe Smart Array P800
AD335A
PCIe
Yes 2
Mini SAS
2
Only 1 will be factory integrated.
PCIe Smart Array P500
AH226A
PCIe
Yes
Mini SAS
2
 
PCI-X 1 port 4 Gb/s Fibre Channel
AB429A
PCI-X
Yes 1
LC
1
 
Local Area Network (LAN) Adapters
HP PCI-X 2-port 1000Base-SX (optical) Gigabit Adapter
A7011A
PCI-X
Yes
1
 
PCI 2 port 1000Base TX
A9900A
PCI-X
Yes
RJ-45
1
 
PCI-X 10GigE SR Fiber Adapter
AD144A
PCI-X
Yes
4x Infiniband Copper
1
Restricted to slot 3
HP PCIe 2 port 1000Base T card
AD337A
PCIe
Yes
RJ-45
2
 
HP PCIe 2 port 1000Base SX card
AD338A
PCIe
Yes
Duplex SC
2
 
1Boot from fibre channel is supported, however not available directly from factory. Boot support must be configured in field.
2Boot from external storage only.

HP Integrity rx2660 Red Hat Enterprise Linux 4 U4 AS and ES Supported I/O Cards
I/O Card
Product Number
PCIe/
PCI-X
Boot Support
Connector Type(s)
Maximum Cards
Special Notes
Mass Storage Host Bus Adapters
PCI-X Smart Array P600 Serial Attached SCSI (SAS) Controller
337972 B21
PCI-X
Yes
SFF8470
1
 
PCI-X 1 port 4 Gb/s Fibre Channel
AB429A
PCI-X
Yes
1
 
PCI-X 266 MHz 2 port 4 Gb/s Fibre Channel
AB379B
PCI-X
Yes
LC
1
 
PCIe 1 port 4 Gb/s Fibre Channel
AE311A
PCIe
Yes
LC
2
PCIe 2 port 4 Gb/s Fibre Channel
AD300A
PCIe
Yes
LC
2
PCI-X 1 port 4 GB/s Fibre Channel
AD167A
PCI-X
Yes
LC
1
PCI-X 2 port 4 GB/s Fibre Channel
AD168A
PCI-X
Yes
LC
1
PCIe 2 port 4 Gb/s Emulex Fibre Channel
A8003A
PCIe
Yes
LC
2
PCIe 1 port 4 Gb/s Emulex Fibre Channel
A8002A
PCIe
Yes
LC
2
PCI 2 channel Ultra320 SCSI
A7173A
PCI-X
Yes
VHDCI
1
HP PCIe SC44Ge SAS HBA
AH303A
PCIe
No
2
PCI-X Smart Array P600 Serial Attached SCSI (SAS) Controller 337972 B21 PCI-X Yes SFF8470 3 Only 2 will be factory integrated.
512 MB cache memory upgrade for SA P600 controller 372538 B21 PCI-X N/A N/A N/A  
PCIe Smart Array P800 AD335A PCIe Yes Mini SAS 2 Only 1 will be factory integrated.
PCIe Smart Array P500 AH226A PCIe Yes Mini SAS 2  
Local Area Network (LAN) Adapters
HP PCI-X 2-port 1000Base-SX (optical) Gigabit Adapter
A7011A
PCI-X
Yes
1
 
PCI 2 port 1000Base TX
A9900A
PCI-X
Yes
RJ-45
1
PCI-X 10GigE SR Fiber Adapter
AD144A
PCI-X
Yes
4x Infiniband Copper
1
Restricted to slot 3
HP PCI-X 266MHz 10GigE SR Card AD385A PCI-X Yes   1  
HP PCIe 2 port 1000Base T card AD337A PCIe Yes RJ-45 2  
HP PCIe 2 port 1000Base SX card AD338A PCIe Yes Duplex SC 2  
* Boot from external storage only.

HP Integrity rx2660 OpenVMS Supported I/O Cards
I/O Card
Product Number
PCIe/
PCI-X
Boot Support
Connector Type(s)
Maximum Cards
Special Notes
Mass Storage Host Bus Adapters
HP PCIe 1 port 4 Gb/s Fibre Channel HBA
AD299A
PCIe
No
LC
2
 
HP PCIe 2 port 4 Gb/s Fibre Channel HBA
AD355A
PCIe
No
LC
2
 
PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel
AB378B
PCI-X
Yes
LC
3
 
PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel
AB379B
PCI-X
Yes
LC
3
 
PCIe 2 port 4 Gb/s Fibre Channel
AD300A
PCIe
Yes
LC
2
 
PCI 2 channel Ultra320 SCSI
A7173A
PCI-X
Yes
VHDCI
3
 
HP PCIe SC44Ge SAS HBA
AH303A
PCIe
Yes
2
 
PCI-X 2 channel Smart Array 6402 Ultra320
A9890A
PCI-X
Yes
VHDCI
2
 
PCI-X 4 channel Smart Array 6404 Ultra320
A9891A
PCI-X
Yes
VHDCI
1
 
PCIe Smart Array P800 AD335A PCIe No Mini SAS 2  
Local Area Network (LAN) Adapters
PCI-X 1 port 1000Base T
AD331A
PCI-X
No
RJ-45
3
 
PCI-X 1-port 1000Base-SX
AD332A
PCI-X
No
LC
3
 
PCI-X 2 port 1000Base SX
A7011A
PCI-X
No
Duplex SC
3
 
PCI-X 2 port 1000Base T
A7012A
PCI-X
No
RJ-45
3
 
PCI-X 4 port 1000Base T Gbit Adapter
AB545A
PCI-X
No
RJ-45
2
 
PCI-X 1 port 10 GbE
AB287A
PCI-X
No
Duplex LC
1
Restricted to slot 3
HP PCI-X 266MHz 10GigE SR Card
AD385A
PCI-X
No
2
HP PCIe 2 port 1000Base T card
AD337A
PCIe
Yes
RJ-45
2
HP PCIe 2 port 1000Base SX card AD338A PCIe Yes Duplex SC 2  
PCIe 4 port HP NC364T Gbit Adapter AD339A PCIe Yes   2  
Multi-Function Cards (Mass Storage/LAN)
PCI-X 2 port 1000Base T/2 port Ultra320 SCSI Multi function Adapter
AB290A
PCI-X
Yes
SCSI - LVD/SE
LAN - RJ-45
2
SCSI bootable
PCI-X 2 Gb Fibre Channel/1000Base SX
A9782A
PCI-X
Yes
LC
3
FC bootable
HP PCI-X 1 port 4 Gb Fibre Channel and 1 port 1000Base T Adapter
AD193A
PCI-X
Yes
(1) LC, (1) RJ-45
2
FC bootable
HP PCI-X 2 port 4 Gb Fibre Channel and 2 port 1000Base T Adapter
AD194A
PCI-X
Yes
(2) LC, (2) RJ-45
2

FC bootable

Additional Interface Cards
PCI ATI Radeon Graphics Adapter
AB551A
PCI
No
VGA
2 PCI-X
2 max with PCI-X backplane, 1 max with PCI-X/PCIe combo  
HP 2D PCI-X graphics card AH391A PCI No VGA T/P/I: PCI-x 2/2/2, PCI-x/PCI-e 1/1/1 Replacing AB551A
AH391A offers 2D graphics support. Support available for HP UX v3

Internal Supported Storage Devices
Device
Product Number
Internal Disk Drives (Optional - Maximum 8)
36-GB 15K RPM SAS (Serial Attached SCSI) 2.5" Small Form Factor Hot Plug Disk
AD378A
72-GB 10K RPM SAS (Serial Attached SCSI) 2.5" Small Form Factor Hot Plug Disk
AD141A
72-GB 15K RPM SAS (Serial Attached SCSI) 2.5" Small Form Factor Hot Plug Disk
AD379A
146-GB 10K RPM SAS (Serial Attached SCSI) 2.5" Small Form Factor Hot Plug Disk
AD333A
Removable Media Drive (Optional – Maximum 1)*
DVD ROM drive, Slimline
AD142A
DVD+RW drive, Slimline (not supported on HP-UX at this time)
AD143A
*DVD drive required for OpenVMS and Windows configurations. Third party software required to support DVD write with Windows.

Integrated Multi-function Core I/O The integrated multi function I/O provides core I/O functionally and includes the management processor, which provides remote management and high availability monitoring capabilities.

Core I/O
  • Two 10/100/1000Base T LAN with RJ 45 connector-Supports LAN boot for operating system installation and wake on LAN capability
  • HP 8 Internal Port SAS (Serial Attach SCSI) Host Bus Adapter, supports up to 8 internal SAS disk drives. Windows does not support the integrated SAS Host Bus Adapter. Windows customers must select the optional HP 8 Port SAS Smart Array P400 RAID controller.
  • May select factory configured RAID. For HP-UX, OpenVMS, and Linux based systems, a maximum of two RAID 1 volumes (2×2 HDDs) and a disk for global hotspare, for a maximum of five disks in RAIDed arrays, is supported. The remaining three disks (of the maximum eight disks that are supported) can be accessed normally, but not configured for RAID. The HP 8 Port SAS Smart Array P400 RAID controller, supported in a PCI Express slot reserved for the RAID controller only, supports RAID 1, 5 and 6. The RAID controller is required for all Windows based systems (Windows does not support the integrated HP 8 Internal Port SAS host bus adapter), and is optional for HP UX, OpenVMS, Linux based systems. The maximum of eight disks can be configured for RAID 1, 5 and 6 in any combination. RAID 1 requires two identical HDDs, RAID5 requires three identical HDDs, and RAID 6 requires four identical HDDs. Factory configuration of a RAID set is available.
  • Three USB 2.0 style A ports (USB 1.1 compatible); one front port, two rear ports
  • One general purpose serial ports; an additional serial port is available for the integrated iLO2 Management Processor
  • Telnet and web console via 10/100Base TX management LAN (RJ 45 connector)

Integrity Integrated Lights Out (iLO2) Management Processor Functionality
  • Dedicated 10/100BaseTX LAN port for LAN console and embedded web console access
  • One RS 232 serial port for local console
  • Password protected console ports
  • Console mirroring between all local, modem, LAN, and web consoles
  • Remote power up and power down control
  • Configurable remote access control
  • Event notification to system console-Provides connectivity, information, and support for HP UX tools (such as STM and EMS) to notify by email, pager and/or HP response centers.
  • Interface to system monitoring and diagnostic hardware via an internal IC bus
  • Secure Sockets Layer security on web console
  • Support for Integrity Integrated Lights Out (iLO2) Advanced Pack version 2 activation key and license (AD301A). Firmware license installs on the integrated Processor Management Card. Integrity Lights Out (iLO2) Advanced Pack provides additional remote management capabilities, including LDAP directory services, Virtual Media (CD, DVD, and ISO impage) for HP-UX, Windows, and Linux and Integrated Remote Console (Virtual Keyboard, Video, and Mouse) for Windows
  • The RN50 integrated chip provides basic graphic capabilities. One VGA port is supported, with optional connection from front or rear of the system.

Supported resolutions and refresh rates include:

Operating System
Minimum Resolution Refresh Rate Maximum Resolution Refresh Rate
HP-UX 1024x768 75 Hz 1920x1200 75 Hz
Linux 1024x768 75 Hz 1920x1200 75 Hz
Windows 640x480 75 Hz 1600x1200 75 Hz