Overview
|
HP Rackmountable 3 Phase Uninterruptible Power Systems (UPS R8000/3 and R12000/3) |
|
|
Crowded data centers and racks filled to capacity with storage devices, monitors, servers communications devices, and other equipment are driving the need for uninterruptible power with increased power density and power efficiency. The HP 3 Phase Uninterruptible Power Systems provide just that. These rack-mountable Uninterruptible Power Systems provide up to 12,000 watts (W) of power in a 6-U rack form factor. This equates to 2 KW per U space, which leads the industry in power density. The UPS R8000/3 and the R12000/3 use digital signal processing and a new On-line On Demand hybrid technology to answer the demands for increased power density and power efficiency. On-line On Demand combines the efficiency of a line interactive UPS, up to 97%, with the stability of a double conversion on-line UPS when power fluctuates beyond acceptable limits. Hot swappable batteries and electronics modules and an automatic bypass reduce MTTR (mean time to repair) down time in the event service is needed. |
|
![]() |
![]() |
|
UPS R8000/3 and R12000/3 front view
|
UPS R8000/3 and R12000/3 rear view
|
| 1. | Battery compartment (behind bezel) | 1. | Communications terminal block |
| 2. | Menu navigation buttons | 2. | Output circuit breaker |
| 3. | Status and alarm LED display | 3. | Input circuit breaker |
| 4. | Electronics module compartment (behind bezel) | 4. | Battery circuit breaker |
| 5. | Input/output location R8000/3, input location R12000/3 1 | ||
| 6. | ERM connector | ||
| 7. | Option card slots | ||
| 8. | Output connector R12000/3 | ||
| 9. | Ground bonding screw | ||
| 10. | DB9 Service port | ||
| 11. | REPO port | ||
|
|
|||
| Models | ||
| HP R8000/3 | HP R8000/3 Uninterruptible Power System 6U |
AF431A
|
|
|
||
| HP R12000/3 | HP R12000/3 Uninterruptible Power System 6U |
AF429A
|
|
|
||
| Key Features |
|
|
|
Product Highlights
| NOTE: For a brief, printer friendly data sheet that describes this product and informs you of the essential capabilities and specifications, please visit: http://h71028.www7.hp.com/ERC/downloads/4AA1-5502ENW.pdf. | |
| Superior Battery Management | HP UPS HP 3 PHASE UPS incorporates Enhanced Battery Management: an exclusive, patented technology that doubles battery service life, optimizes battery recharge time, and provides advance notice of pending battery failure. With Enhanced Battery Management, you have a lower total cost of ownership and receive the best in the industry protection for your critical equipment. |
|
| |
| Ease of serviceability through hot-swappable batteries and electronics modules. |
The HP 3 PHASE UPSs have a modular design architecture, consisting of separate, hot swappable battery and electronics modules. Further, a built-in intelligent automatic bypass feature ensures continuous power to your connected load even while the modules are being replaced. Ease of maintenance and serviceability
|
|
| |
| Increase battery back-up time with up to four Extended Runtime Modules | HP 3 PHASE UPS supports a maximum of four Extended Runtime Modules (ERM), to further increase your battery back-up time, should you have a sudden brief power outage. Each ERM is 3U high and can be automatically detected and configure when attached to the UPS. For more information on battery back up times, please refer to the Back-up Times Chart. |
| | |
| Multiple management options increase flexibility | The HP 3 Phase UPS systems can bee fully configured and monitored from the front management LCD. For remote management the HP UPS Management Module is included at no charge and provides additional features such as out of band communications with up to 5 servers and UPS clustering for redundancy. |
|
| |
| Remote Emergency Power Off Feature | The HP 3 Phase UPS includes an isolated REPO (Remote Emergency Power Off) port. The REPO feature allows the power to the UPS outlets to be switched off from a remote location. For more information, refer the HP 3 Phase UPS users manual. |
| | |
| UPS Management Module | The HP UPS Management Module
enables you to monitor and manage power environments through comprehensive
control of HP UPSs. The HP UPS Management Module can support either a single
UPS configuration or provides additional power protection with support for
dual redundant UPS configuration for no-single-point-of-failure. The additional
serial ports will provide greater power management control and flexible
monitoring.
The management module can be configured to send alert traps to HP Systems
Insight Manager and other SNMP management programs or used as a standalone
management system. This flexibility enables you to monitor and manage
UPSs through the network. To facilitate day-to-day maintenance tasks,
the embedded management software provides detailed system logs. |
|
|
Service and Support, HP Care Pack, and Warranty Information
| Warranty |
|
| | |
| HP Care Pack Services |
HP Care Pack Services include HP branded hardware options qualified for the server, purchased at the same time or afterwards, internal to the enclosure, as well as 22" and smaller external monitors and rack mounted UPS options. HP Uninterruptible Power Systems will be covered at the same service level and coverage period as the server. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. NOTE: For more information on HP Care
Pack services, contact any of our worldwide sales offices or resellers
or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack |
|
|
Related Options
| Extended Runtime Module |
Extended Runtime Module
NOTE: HP 3 PHASE UPS supports a maximum of four Extended Runtime Modules (ERM), to further increase your battery back-up time. Each ERM is 3U high and can be automatically detected and configure when attached to the UPS. For more information on battery back up times, please refer to the Back-up Times Chart. |
AF434A
|
|
|
||
| Serial Adapters for UPS Management Module |
HP Serial Adapter RJ45-DB89 DCE Female 5pk
NOTE: The serial adapters allow direct (serial) connections to up to 5 servers with the UPS Management Module for out of band communications in the event of a power failure. |
AF402A
|
|
|
||
| Rackmount Power Distribution Units (PDUs) and PDU options | 8.6 kVA 3Φ Modular PDU (core only) with L15-30 inlet cord and 6 x IEC C19 outlets |
AF512A
|
| 8.6 kVA 3Φ Monitored PDU model S1324 with one L15-30 inlet cord, and 36 IEC C-13 plus 3 IEC C19 outlets |
AF504A
|
|
| 17.3 kVA 3Φ Monitored PDU model S2324 with two L15-30 inlet cords, and 72 IEC C-13 plus 6 IEC C19 outlets |
AF503A
|
|
| NOTE: The HP R8000/3 UPS can support one AF512A or AF504A. The HP R12000/3 UPS can support two AF512A or AF504A or one AF503A. | ||
| PDU Management Module NOTE: For more information on the PDU Management Module please see http://h18004.www1.hp.com/products/servers/proliantstorage/ powerprotection/pdu.html |
AF400A
|
|
|
|
||
| PDU Extension Bars (PDU options) | HP C-13 PDU Extension Bar Kit,
pair NOTE: Each extension bar has a C-20 input cord and 7 x C-13 receptacles. |
AF500A
|
| HP Fixed Cord Extension Bar
Kit, pair NOTE: Each extension bar has a C-20 input cord and 7 attached 13 inch C-13 power cords for use with 1U servers |
351655-B21
|
|
| NOTE: Extension bars may be used with any HP PDU that has C-19 outlets | ||
|
|
||
| HP Power Cables | 10A, IEC320 C-14 to IEC320 C-13 Cables, 4.5ft (1.37m), 15 pack |
142257-007
|
| 10A, IEC320 C-14 to IEC320 C-13 Cables, 4.5ft (1.37m), single 15 pack |
142257-006
|
|
| 10A, IEC320 C-14 to IEC320 C-13 Cables, 1.6ft (0.5m), single pack |
142257-B28
|
|
| 16A, IEC320 C-19 to IEC320 C-20 Cables, 8ft (2.5m), single pack |
295633-B22
|
|
| 16A, IEC320 C-19 to IEC320 C-20 Cables, 6.5ft (2m), single pack |
AF574A
|
|
| 16A, IEC320 C-19 to IEC320 C-20 Cables, 4ft (1.2m), single pack |
AF575A
|
|
| 16A, IEC320 C-19 to IEC320 C-20 Cables, 3ft (1m), single pack |
E7798A
|
|
| NOTE: For more information on HP power cords please go to: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/power-cord-option-kits.pdf | ||
|
|
||
| Service and Support Offerings
(HP Care Pack Services) |
Hardware Installation (Electronic) |
U4696E
|
|
|
Technical Specifications
| R8000/3 | R12000/3 |
| Electrical Output | Power Output | 8kVA/8KW @ 208v 3Φ Delta | 12kVA/12KW @ 208v 3Φ Delta |
| Nominal output frequency | 50-60 Hz auto-detection
(Normal mode) 50 or 60 Hz (Battery mode) |
||
| Output Frequency Variation | Synchronized (Normal
mode) ±0.1 when not synchronized with source (Battery mode) |
||
| Output overload | 100110%:
load transfers to Bypass mode after 10 minutes 110125%: load transfers to Bypass mode after 1 minute 125150%: load transfers to Bypass mode after 5 seconds >150%: load transfers to Bypass mode after 300 ms |
||
| Voltage wave form | Sine wave; 2% THD with typical PFC load | ||
| Surge suppression | High-energy 6500 A peak | ||
| Noise filtering | MOVs and line filter | ||
| Output Connections | One NEMA L15-30R | Two NEMA L15-30R | |
| Electrical Input | Voltage Range |
200-240 v 3Φ Wye | 208v 3Φ Wye |
| Nominal voltage | 208v 3Φ Wye | 208v 3Φ Wye | |
| Nominal frequency |
50/60 Hz | 50/60 Hz | |
| Frequency range |
45-65 Hz | 45-65 Hz | |
| Rated input current | |||
| Maximum input current at nominal voltage | |||
| Efficiency | 97% @ 40-100% load | 97% @ 40-100% load | |
| Input connector | NEMA L21-30 (30A) | IEC309 560P9 (60A) | |
| Operating Temperature | Operating Temperature | 50° F to 104° F (10° C to 40° C) | |
| Optimal battery performance | 41° F to 77° F (5° C to 25° C) | ||
| Non-operating Temperature | -13°F to 131°F (-25°C to 55°C) | ||
| Relative Humidity | Operating | 5% to 95% non-condensing | |
| Operating Altitude | Up to 3300 ft (1,000
meters) above sea level; up to 6600 ft (2,000 meters) with 1% derating per +330 ft (100 meters) |
||
| Transit Altitude | Up to 49,212 ft (15,000 meters) above sea level | ||
| Heat Dissipation | 1266 BTU/hr maximum at 100% rated load (High Efficiency mode) | ||
| Audible Noise | Less than 50 dBA at 1 meter
(Normal mode) Less than 55 dBA at 1 meter (Battery mode) |
||
| Leakage Current | < 3.5 mA | ||
| Surge suppression | ANSI C62.41 Category B3 | ||
| Safety Conformance | UL 1778 4th edition; CSA C22.2, No. 107.3 | UL 1778 4th edition; CSA C22.2, No. 107.3 | |
| EMC (Class A) | FCC Part 15 | FCC Part | |
| Unit Dimensions (WxDxH) | 14.4 x 26 x 10.3 in (441 x 660 x 261 mm) 6U | ||
| Shipping Dimensions (WxDxH) | 25 x 38 x 46 in (635 x 965 x 1169 mm) | ||
| Unit Weight | Without batteries | 135 lb (61 kg) | |
| With batteries installed | 307 lb (140 kg) | ||
| Shipping Weight | 400 lbs (182 kg) | ||
| Extended Runtime Module (ERM) | Unit Dimensions (WxDxH) |
17.2 x 26 x 5.2 in (438 x 660 x 131 mm) 3U | |
| Shipping Dimensions (WxDxH) |
47.25 x 31.5 x 37 in (1207 x 800 x 940 mm) | ||
| Unit Weight |
170 lbs (77 kg) | ||
| Shipping Weight |
185 lb (84 kg) | ||
|
|
|||
| Estimated Backup Times Chart (Minutes) R8000/3 |
|
Load %
|
With Internal Battery
|
With 1 ERM
|
With 2 ERMs
|
With 3 ERMs
|
With 4 ERMs
|
|
20%
|
55
|
118
|
183
|
253
|
329
|
|
50%
|
23
|
46
|
69
|
94
|
120
|
|
80%
|
12
|
27
|
41
|
55
|
70
|
|
100%
|
9
|
21
|
32
|
43
|
54
|
| Estimated Backup Times Chart (Minutes) R12000/3 |
|
20%
|
37
|
78
|
119
|
163
|
211
|
|
50%
|
13
|
30
|
44
|
59
|
76
|
|
80%
|
6
|
17
|
26
|
34
|
44
|
|
100%
|
5
|
12
|
20
|
27
|
34
|
| NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions. | |||||
|
Environment-friendly Products and Approach |
End-of-life Management and Recycling | Hewlett-Packard offers end-of-life HP product
return, trade-in, and recycling programs in many geographic areas. For trade-in
information, please go to http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will be
recycled, recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
|
|
||
|
© Copyright 2007 Hewlett-Packard Development Company, L.P. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |