Overview
|
HP ProLiant DL120 Generation 5 (G5) |
|||
|
|
|||
| Front View: | Rear View: | ||
|
1.
|
Cover |
1.
|
Power supply cable socket |
|
2.
|
Four PC2-6400 UB ECC DDR2 Memory Slots |
2.
|
Mouse connector |
|
3.
|
Processor Socket (Intel® Xeon®, Core™2,
Pentium® or Celeron®) |
3.
|
USB connectors (2) |
|
4.
|
Serial connector | ||
|
4.
|
Power Supply (350 Watt) |
5.
|
Expansion slot 2, PCI-e x4, low-profile, half-length |
|
5.
|
3 Non Hot Plug Dual Rotor Fans |
6.
|
Expansion slot 1, PCI-e x8, Full high, Full-length (PCI-X optional) |
|
6.
|
Optional 12.7mm DVD-ROM, or DVD-RW Drive | ||
|
7.
|
Two upfront USB connectors |
7.
|
UID button/LED |
|
8.
|
Power Button, UID Button, and Front LED Indicators |
8.
|
Video connector |
| 9. | Support for up to two Non-Hot Plug SATA or SAS Hard Drives | 9. | DL120 G5 HP Lights Out 100c management NIC port (optional) |
| 10. | Two PCI express Slots (2 PCI-Express x8 connectors standard, one x8, one x4 Lanes) | 10. | NIC Port |
| 11. | Keyboard connector | ||
|
|
|||
|
What's New |
|
| |
| At a Glance |
The HP ProLiant
DL120 G5 Server is an entry-level rack-optimized server providing you with all
confidence of a HP ProLiant server. The single processor, 1U server is ideal for
single-application IT infrastructure, web and edge-of-network applications. The
HP ProLiant DL120 provides two PCI-Express slots with an option to replace one
PCI-Express slot with a PCI-X slot. Optional upgrades, including HP HBAs and Smart
Array Controllers, provide support for SAS hard disk drives. An optional DL120G5
HP Lights Out 100c (LO100c) Remote Management Card provides cost-effective remote
management from anywhere, anytime. Plus, you get the cost-effective solution of
a single-processor platform with the performance advantages of dual-core or quad-core.
|
|
|
Standard Features
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | |
| Processor One of the following depending on Model | Quad-Core Processors |
| Quad-Core
Intel® Xeon® processor X3360 (2.83GHz, 12MB L2 cache, 95 Watts, 1333MHz
Front Side Bus FSB) NOTE: Available via Configure-to-order only. See Factory Integrated Models section for more details. | |
| Quad-Core Intel® Xeon®
processor X3350 (2.66GHz, 12MB L2 cache, 95 Watts, 1333MHz FSB) NOTE: Available via Configure-to-order only. See Factory Integrated Models section for more details. | |
| Quad-Core
Intel® Xeon® processor X3330 (2.66 GHz, 6MB L2 cache, 95 Watts, 1333MHz
FSB) NOTE: Available via Configure-to-order only. See Factory Integrated Models section for more details. | |
| Quad-Core Intel® Xeon®
processor X3320 (2.5GHz, 6MB L2 cache, 95 Watts, 1333MHz FSB) NOTE: Available via Configure-to-order only. See Factory Integrated Models section for more details. | |
| Intel® Xeon® processor
X3220 (2.4GHz, 8MB L2 cache, 1066Watts, MHz FSB) NOTE: Available via Configure-to-order only. See Factory Integrated Models section for more details. |
|
| Quad-Core Intel® Xeon®
processor X3210 (2.13GHz, 8MB L2 Cache, 95 Watts, 1066MHz FSB) NOTE: Available via Configure-to-order only. See Factory Integrated Models section for more details. | |
| Intel®
Xeon® processor E5200 (2.50 GHz, 2 MB L2 cache, 65Watts, 800MHz Front Side
Bus FSB, 2M) NOTE: Available via Configure-to-order only. See Factory Integrated Models section for more details. | |
| Intel® Xeon® processor E7400 (2.80 GHz, 3MB L2 cache, 65Watts, 1066MHz Front Side Bus FSB, 3M) NOTE: Available via Configure-to-order only. See Factory Integrated Models section for more details. | |
| Dual-Core Processors | |
| Dual-Core
Intel® Xeon® processor E3120 (3.16 GHz, 6MB L2 cache, 65 Watts, 1333MHz
FSB) NOTE: Available via Configure-to-order only. See Factory Integrated Models section for more details. | |
| Dual-Core Intel® Xeon®
processor E3110 (3.0GHz, 6MB L2 cache, 65 Watts, 1333MHz FSB) NOTE: Available via Configure-to-order only. See Factory Integrated Models section for more details. | |
| Dual-Core Intel® Xeon® processor 3065 (2.33GHz, 4MB L2 Cache, 65 Watts, 1333MHz FSB) | |
| Dual-Core Intel®
Core™2 processor E4600 (2.4GHz, 2MB L2 cache, 800MHz FSB) NOTE: Available via Configure-to-order only. See Factory Integrated Models section for more details. | |
| Dual-Core Intel® Pentium® processor E2160 (1.80GHz, 1MB L2 cache, 800MHz FSB) | |
| Single-Core Processors | |
| Single-Core
Intel® Celeron® processor 440 (2.00GHz, 512KB L2 cache, 800MHz FSB) NOTE: Available via Configure-to-order only. See Factory Integrated Models section for more details. | |
| Single-Core Intel® Celeron®
processor 420 (1.60GHz, 512KB L2 cache, 800MHz FSB) NOTE: Available via Configure-to-order only. See Factory Integrated Models section for more details. | |
|
| |
| Cache
Memory One of the following depending on Model | 12
MB L2 Cache NOTE: For Models with Intel® Xeon® processor X3360, and X3350. |
| 8
MB L2 Cache NOTE: For Models with Intel® Xeon® processor X3330, X3320, E3120, and E3110. | |
| 6 MB L2 Cache NOTE: For Models with Intel® Xeon® processor X3320 and E3110. | |
| 4 MB L2 Cache NOTE: For Models with the Intel® Xeon® processor 3065. | |
| 2 MB L2 Cache NOTE: For Models with the Intel® Core2 processor E4600. | |
| 1 MB L2 Cache NOTE: For Models with the Intel® Pentium processor E2160. | |
| 512 KB L2 Cache NOTE: For Models with the Intel® Celeron processor 440 and 420. | |
| | |
|
Chipset | Intel® 3200 Chipset |
| | |
| Memory Protection | ECC |
|
|
|
| Memory One of the following depending on Model |
Type | PC2-6400 (800MHz) Unbuffered
ECC DDR2 SDRAM Interleaving optional (Enabled when DIMMs populated in pairs) |
| DIMM Sockets | 4 | |
| Standard - Xeon 3065 and Pentium E2160 Models | 1 GB (1 x 1 GB) | |
| Standard - Xeon 3320 Model | 2 GB (2 x 1 GB) | |
| Maximum Memory | 8 GB | |
|
|
||
| Network Controller | Embedded NC105i Gigabit Server Adapter |
|
| |
| Expansion Slots | Technology | Bus Width*** |
Connector Width | Bus Number* | Device No.** | Form Factor |
Notes |
| 1 (Standard) |
PCIe | X8 | x8 | 0 | 1 | Full length, full height slot | This PCIe slot can be replaced with optional PCI-X slot below |
| 2 (Standard) |
PCIe | X4 | x8 | 0 | 28 | Low profile slot | |
| 1 (Optional) |
PCI-X (133MHz, 3.3Volt) | 64-bit | N/A | 0 | 1 | Full length, full height slot | |
| * Default bus assignment (in decimal). Inserting cards with PCI bridges may alter the actual bus assignment number. | |||||||
| ** Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest Device ID by bus (starting with the lowest bus) | |||||||
| *** Indicates the number of physical electrical lanes running to a PCI-e connector. | |||||||
|
|
|||||||
| Storage Controllers | Integrated Intel® 82801IR
Serial ATA Host Controller with RAID 0/1 support. NOTE: The non-hot-plug drive option kits include a SATA cable along with the drive itself. This cable allows the drives to be connected to the embedded SATA controller. The cables are point to point. |
| SAS and SATA controllers available
via PCI card option NOTE: If a HBA or SAS controller is ordered for SATA RAID or SAS support, the 4 Lane SAS/SATA Host Fan Out Cable Kit (P/N 457692-B21) must also be ordered to connect the drives. |
|
|
|
|
| Storage | Optical Drive | Optional 12.7mm DVD-ROM, or DVD-RW Drive | |
| Hard Drives |
Non-Hot Plug SATA /SAS | Up to
2 non-hot plug SATA/SAS 3.5" drives NOTE: SAS requires optional HBA or SA card. | |
|
| |||
| Maximum Internal Storage Type | Non-Hot Plug SATA | 1.5TB | 2 x 750GB SATA |
| Non-Hot Plug SAS | 900GB | 2 x 450GB SAS | |
| | |||
| Interfaces | Serial | 1 |
| USB 2.0 | 5 (2 front, 1 internal, 2 rear) NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html |
|
| Graphics | 1 (rear) | |
| Keyboard | 1 | |
| Mouse | 1 | |
| Management | 1 for optional LO100c | |
| Network RJ-45 | 1 | |
|
|
||
| Graphics |
32MB shared supporting 1600x1200x16M resolution |
| | |
| Form Factor | Rack (1U), (1.69 in/4.30 cm), 27.5" deep |
| | |
| Remote Management | Lights-Out 100c | Lights Out LO100c is a Remote Management Card (RMC) for ProLiant 100 series servers that do not have embedded LO100i. The LO100c has all the features of the LO100i Advanced license and allows customers, or their service providers, to remotely manage ProLiant servers over a LAN or the Internet from anywhere, anytime regardless whether the server is located in the same building, across town, or around the globe. With LO100c, users can acquire complete remote control with Virtual KVM (graphical hardware-based, remote console). Users can also access the server's serial console, control system power, update system firmware and software, as well as monitor system environmental conditions. The LO100c remote management card can be accessed from a web browser or command line interface. This virtual "at-the-server" functionality means administrators stay in control of remote HP ProLiant 100 series servers. The HP Lights-Out100c consists of a management processor and firmware that provides cost-effective, entry-level lights-out functionality, basic system board management functions, and diagnostics. |
| NOTE:
For more information, please refer to the QuickSpecs for the LO100c
found at: http://h18004.www1.hp.com/products/servers/management/ remotemgmt.html |
||
| | ||
| Core Infrastructure Management | Subscriber's Choice | Subscriber's Choice Driver
and Support Alerts/Notifications is a web-based email subscription service that
provides software and driver change notifications for ProLiant products. Sign
up at: http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis. |
| ROMPaq software and drivers | The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options, available through software and drivers download pages website at: http://www.hp.com/go/support. | |
| | ||
| Industry Standard Compliance | ACPI 3.0 |
| PCI 2.3 Compliant | |
| PXE Support | |
| WOL Support | |
| Microsoft® Logo certifications | |
| USB 2.0 | |
| IPMI 2.0 | |
| | |
| Intelligent Manageability | Automatic
Server Recovery (ASR) |
|
| |
| Security | Power-on
password Keyboard password USB Port control Removable DVD-ROM Drive Assembly (optional) Dedicated LO100c management NIC port (optional) Administrator's password |
| | |
| Server Power Cords | One 6' Highline (IEC-IEC) power cord ships standard |
| NOTE: HP ProLiant DL120 G5p server ship standard with a C13 to C14 2M Highline jumper cord. If customers require a power cord, they can check the power cord matrix for the appropriate cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix. | |
|
|
|
| Power Supply | Auto-sensing 350-Watt PFC Power Supply, CE Mark Compliant |
|
| |
| UPS
and PDU Power Cord Matrix | Please
see the UPS and PDU cable matrix that lists cable descriptions, requirements,
and specifications for UPS and PDU units: http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/index.html |
| | |
| System Fans | 3 dual rotor fans ship standard. 3 dual rotor fans total supported internally. |
|
| |
| Required Cabling | For required cabling information, refer to the Web site at: http://h10010.www1.hp.com/wwpc/us/en/sm/WF05a/15351-15351-3328412-241644-241475-3579703.html. |
| | |
| Operating Systems and Virtualization Software | Microsoft
Windows Server Red Hat Enterprise Linux (RHEL) SUSE Linux Enterprise Server (SLES) |
|
NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/supportos and our driver download page http://www.hp.com/support/DL120G5 | |
| | |
| Rack Airflow Requirements | Rack
10000 series Cabinets |
| CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://h18004.www1.hp.com/products/servers/proliantdl120/index.html. | |
| | |
| Rack Kit |
The DL120 G5 Fixed Rail System supports installation in racks with square or round mounting holes (including Compaq/HP 7000, 9000, 10000 and HP series), with an adjustment range of 24" - 36". Installation into Telco 2 post, and 4 post, or threaded holes racks requires a 3rd party option kit. Go to: www.racksolutions.com for more information. |
|
| |
| HP Factory Express Capabilities |
HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to: http://www.hp.com/go/factory-express. |
| | |
| Service and Support | HP Care Pack Services provide total care and support expertise with committed response times designed to meet your IT and business needs. HP Care Pack services include coverage for the HP branded hardware options qualified for the server that are purchased at the same time or afterward and internal to the enclosure. It also includes the 22-inch and smaller external monitors and tower UPS options up to 3kVA. These items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included and standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. To fully capitalizing on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of support solutions provides a range of support services designed to meet the varying needs of your business. Whether an SMB, or large global corporation, HP has ProLiant server support offers to help you speedily deploy and maximize system uptime. Recommended Service - simplify ProLiant solution implementation, maintenance, and management.
Enhanced Service - optimize service level to increase IT performance and availability.
Refer to the information on the Installation of a ProLiant on the ProLiant Data Sheet; to be delivered on a scheduled basis 8am-5pm, M-F, excluding HP holidays. NOTE:
For a complete listing of service offerings and information visit: |
|
|
Models
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | ||
| HP
DL120 G5 E3110, 1GB, A160, SATA 533983-001 | Processor | Intel® Pentium® processor E3110 (3.0 GHz, 6MB L2 cache, 65Watts, 1333 FSB) |
| Cache Memory | 4MB L2 Cache | |
| Memory | 1 GB (Standard) to 8 GB (Maximum) of ECC PC2-6400 Unbuffered DDR2 SDRAM Memory | |
| Network Controller | Embedded NC105i Gigabit Server Adapter | |
| Storage Controller | Intel 82801 IR Integrated Serial ATA Host Controller | |
| Hard Drives | 1 x 160GB 3.5" Non-hot-plug SATA | |
| Internal Storage | Non-Hot
Plug SAS: 600GB maximum Non-Hot Plug SATA: 1.0TB maximum NOTE: SAS requires optional PCI Controller | |
| Optical Drive | Optional | |
| Power Supply | Auto-sensing 350-Watt PFC Power Supply, CE Mark Compliant | |
| Form Factor | Rack (1U), (1.69 in/4.30 cm) | |
| | ||
| HP
DL120 G5 X3330, 2GB, A160, SATA 533984-001 | Processor | Intel® Pentium® processor X3330 (2.66GHz, 6MB L2 cache, 95 Watts, 1333 FSB) |
| Cache Memory | 6MB L2 Cache | |
| Memory | 2 GB (2x1 GB) (Standard) to 8 GB (Maximum) of ECC PC2-6400 Unbuffered DDR2 SDRAM Memory | |
| Network Controller | Embedded NC105i Gigabit Server Adapter | |
| Storage Controller | Intel 82801 IR Integrated Serial ATA Host Controller | |
| Hard Drives | 1 x 160GB 3.5" Non-hot-plug SATA | |
| Internal Storage | Non-Hot
Plug SAS: 600GB maximum Non-Hot Plug SATA: 1.0TB maximum NOTE: SAS requires optional PCI Controller | |
| Optical Drive | Optional | |
| Power Supply | Auto-sensing 350-Watt PFC Power Supply, CE Mark Compliant | |
| Form Factor | Rack (1U), (1.69 in/4.30 cm) | |
| | ||
| DL120
E2160 1GB A160 SATA 465475-001 | Processor | Intel® Pentium® processor E2160 (1.80GHz, 1MB L2 cache, 800MHz FSB) |
| Cache Memory | 1MB L2 Cache | |
| Memory | 1 GB (Standard) to 8 GB (Maximum) of ECC PC2-6400 Unbuffered DDR2 SDRAM Memory | |
| Network Controller | Embedded NC105i Gigabit Server Adapter | |
| Storage Controller | Intel® 82801IR Integrated Serial ATA Host Controller | |
| Hard Drives | 1 x 160GB 3.5" Non-hot-plug SATA | |
| Internal Storage | Non-Hot
Plug SATA: 1.5TB maximum NOTE: SAS requires optional PCI Controller. | |
| Optical Drive | Optional | |
| Power Supply | Auto-sensing 350-Watt PFC Power Supply, CE Mark Compliant | |
| Form Factor | Rack (1U), (1.69 in/4.30 cm) | |
| | ||
| DL120
3065 1GB A160 SATA 465476-001 | Processor(s) | Intel® Xeon® processor 3065 (2.33GHz, 4MB L2 cache, 1333MHz FSB) |
| Cache Memory | 4MB L2 Cache | |
| Memory | 1 GB (Standard) to 8 GB (Maximum) of ECC PC2-6400 Unbuffered DDR2 SDRAM Memory | |
| Network Controller | Embedded NC105i Gigabit Server Adapter | |
| Storage Controller | Intel® 82801IR Integrated Serial ATA Host Controller | |
| Hard Drives | 1 x 160GB 3.5" Non-hot-plug SATA | |
| Internal Storage | Non-Hot
Plug SATA: 1.0TB maximum NOTE: SAS requires optional PCI Controller. | |
| Optical Drive | Optional | |
| Power Supply | Auto-sensing 350-Watt PFC Power Supply, CE Mark Compliant | |
| Form Factor | Rack (1U), (1.69 in/4.30 cm) | |
| | ||
| DL120
X3320 2GB A160 SATA 469378-001 | Processor(s) | Intel® Xeon® processor X3320 (2.50GHz, 6MB L2 cache, 1333MHz FSB) |
| Cache Memory | 6MB L2 Cache | |
| Memory | 2 GB (2x1 GB) (Standard) to 8 GB (Maximum) of ECC PC2-6400 Unbuffered DDR2 SDRAM Memory | |
| Network Controller | Embedded NC105i Gigabit Server Adapter | |
| Storage Controller | Intel® 82801IR Integrated Serial ATA Host Controller | |
| Hard Drives | 1 x 160GB 3.5" Non-hot-plug SATA | |
| Internal Storage | Non-Hot
Plug SATA: 1.0TB maximum NOTE: SAS requires optional PCI Controller. | |
| Optical Drive | Optional | |
| Power Supply | Auto-sensing 350-Watt PFC Power Supply, CE Mark Compliant | |
| Form Factor | Rack (1U), (1.69 in/4.30 cm) |
|
|
Smart Buys
| The ProLiant Smart Buy program offers a collection of promotional server and option products that are configured with SMB in mind, offered at discounted prices, and positioned for quick delivery. Smart Buy server offers are available for a limited time only. | ||
| S-Buy
DL120G5 X3320 NHP SATA 480572-005 | Processor(s) | (1) Quad-Core Intel® Xeon® processor X3320 (2.5GHz, 6MB L2 cache, 95 Watts, 1333MHz FSB) |
| Cache Memory | 6MB L2 Cache | |
| Memory | 2 GB (1 x 2 GB) Unbuffered PC2-6400 ECC | |
| Network Controller | Integrated NC105i Gigabit Server Adapter | |
| Storage Controller | Intel® 82801IR Integrated Serial ATA Host Controller | |
| Hard Drives | (2) 160GB Non-hot plug SATA 3.5" | |
| Internal Storage | SAS: 600GB maximum;
SATA: 1.5TB maximum NOTE: SAS requires optional PCI Controller. | |
| Optical Drive | DVD-ROM | |
| Power Supply | Auto-sensing 350-Watt PFC Power Supply, CE Mark Compliant | |
| Form Factor | Rack (1U), (1.69 in/4.30 cm) | |
| | ||
| S-Buy
DL120G5 X3360 NHP SATA 498242-005 | Processor(s) | (1) Quad-Core Intel® Xeon® Core 2 Processor X3360 (2.83 GHz, 95W, 1333MHz FSB) |
| Cache Memory | 12 MB L2 Cache | |
| Memory | 2 GB (1 x 2 GB) Unbuffered PC2-6400 ECC | |
| Network Controller | Integrated NC105i Gigabit Server Adapter | |
| Storage Controller | Intel® 82801IR Integrated Serial ATA Host Controller | |
| Hard Drives | (1) 250GB Non-hot plug SATA 3.5" | |
| Internal Storage | SAS: 900GB maximum;
SATA: 1.5TB maximum NOTE: SAS requires optional PCI Controller. | |
| Optical Drive | DVD-RW | |
| Power Supply | Auto-sensing 350-Watt PFC Power Supply, CE Mark Compliant | |
| Form Factor | Rack (1U), (1.69 in/4.30 cm) |
|
|
Configuration Information - Factory Integrated Models
| NOTE:
This section lists some of the steps required to configure a Factory Integrated
Model. To ensure only valid configurations are ordered, HP recommends the use
of an HP approved configurator. Contact your local sales representative for information
on CTO product offerings and requirements. NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis. NOTE: FIO indicates that this option only available as a Factory Installable Option. | ||
| Step 1: Base Configuration (choose one of the following configurable models) | ||
| Models | DL120 CTO (Configure-To-Order) Non-Hot Plug Chassis |
468653-B21 |
| Includes: | ||
| Embedded NC105i Gigabit Server Adapter | ||
| 1 full length PCI Express x8 slot (x8 lane) and 1 half length low profile PCI Express x8 slot (x4 lane) | ||
| Intel® 82801IR Integrated Serial ATA Host Controller | ||
| Rack (1U) form factor, (1.69 in/4.30 cm) | ||
| Fixed, mounting rails | ||
| | ||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processors | Intel® Celeron 420 processor (1.60GHz, 512KB L2 cache, 800MHz FSB), FIO Kit |
450125-L22
|
| Intel® Celeron 440 processor (2.00GHz, 512KB L2 cache, 800MHz FSB), FIO Kit |
468963-L22
|
|
| Intel® Pentium E2160 processor (1.80GHz, 1MB L2 cache, 800MHz FSB), FIO Kit |
455035-L22
|
|
| Intel® Core2 E4600 processor (2.4GHz, 2MB L2 cache, 800MHz FSB), FIO Kit |
482110-L22
|
|
| Intel® Xeon® 3065 processor (2.33GHz, 4MB L2 Cache, 65 Watts, 1333MHz FSB), FIO Kit |
450143-L22
|
|
| Intel® Xeon® E3110 processor (3.0GHz, 6MB L2 cache, 65 Watts, 1333MHz FSB), FIO Kit |
463436-L22
|
|
| Intel® Xeon® processor E3120 processor (3.16 GHz, 6MB L2 cache, 65 Watts, 1333MHz FSB), FIO Kit |
493241-L22
|
|
| Intel® Xeon® X3360 processor (2.83GHz, 12MB L2 cache, 95 Watts, 1333MHz Front Side Bus FSB), FIO Kit | 493245-L22 | |
| Intel® Xeon® X3330 processor (2.66 GHz, 6MB L2 cache, 95 Watts, 1333MHz FSB), FIO Kit | 493243-L22 | |
| Intel® Xeon® processor X3220 (2.40GHz, 8MB L2 cache, 1066MHz FSB) | 533995-L22 | |
| Intel® Xeon® X3210 processor (2.13GHz, 8MB L2 Cache, 95 Watts, 1066MHz FSB), FIO Kit | 455031-L22 | |
| Intel® Xeon® X3320 processor (2.5GHz, 6MB L2 cache, 95 Watts, 1333MHz FSB), FIO Kit |
463434-L22
|
|
| Intel® Xeon® X3350 processor (2.66GHz, 12MB L2 cache, 95 Watts, 1333MHz FSB), FIO Kit |
463432-L22
|
|
| Intel® Xeon® processor E5200 (2.50 GHz, 2MB L2 cache, 65Watts, 800MHz FSB), FIO Kit | 533991-L22 | |
| Intel® Xeon® processor E7400 (2.80 GHz, 3MB L2 cache, 65Watts, 1066MHz FSB), FIO Kit | 533993-L22 | |
| Memory | 2 GB Unbuffered PC2-6400 ECC DIMM (1 x 2 GB) |
450260-B21
|
| 1 GB Unbuffered PC2-6400 ECC DIMM (1 x 1 GB) |
450259-B21
|
|
| 512 MB Unbuffered PC2-6400 ECC DIMM (1 x 512 MB) |
450258-B21
|
|
| Hard Drives | NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the HBA or Controller. Refer to the HBA or Controller technical specifications for details. | |
| SATA Non-Hot Plug Midline (MDL) Drives | ||
| HP 750GB 3G SATA 7.2K NHP 3.5" MDL HDD | 462595-B21 | |
| HP 500GB 3G SATA 7.2K NHP 3.5" MDL HDD | 458941-B21 | |
| HP 250GB 3G SATA 7.2K NHP 3.5" MDL HDD | 458939-B21 | |
| SATA Non-Hot Plug Entry (ETY) Drives | ||
| HP 160GB 3G SATA 7.2K NHP 3.5" ETY HDD | 458947-B21 | |
| SAS Enterprise (ENT) Drives 3.5" Drives, Non-Hot Plug | ||
| HP 400GB 3G SAS 10K 3.5" DP NHP ENT HDD | 508232-B21 | |
| HP 450GB 3G SAS 15K 3.5" DP NHP ENT HDD | 454234-B21 | |
| HP 300GB 3G SAS 15K 3.5" DP NHP ENT HDD | 417950-B21 | |
| HP 300GB 3G SAS 15K 3.5" SP NHP ENT HDD | 431950-B21 | |
| HP 146GB 3G SAS 15K 3.5" DP NHP ENT HDD | 417855-B21 | |
| HP 146GB 3G SAS 15K 3.5" SP NHP ENT HDD | 432093-B21 | |
| HP 72GB SAS 15K 3.5" SP NHP ENT HDD |
432095-B21
|
|
| NOTE: If SAS Enterprise Drives are selected, must select a SAS controller in Step 3 below. | ||
|
|
||
| Step 3: Choose Additional Factory Integratable Options (only one of the following from each list unless otherwise noted) | ||
| Storage Controllers | SAS Controllers (Only Required if NHP SAS Hard Drive selected in Step 2) | |
| HP
Internal SAS/SATA 4-Port Cable NOTE: This cable option kit is automatically included in any CTO configuration when a HBA or SAS controller is selected. |
457692-B21 | |
| HP Smart Array E200/128 BBWC Controller |
411508-B21 | |
| HP Smart Array P800/512 MB BBWC Controller | 381513-B21 | |
| SAS HBA | ||
| HP
SC44Ge Host Bus Adapter NOTE: When using the SC44Ge with SATA Hard Drives, 1.5G SATA Hard Drives are required. Transfer rate: 1.5 Gb/s SATA, 3 Gb/s SAS. |
416096-B21 | |
| HP
SC40Ge Host Bus Adapter, FIO NOTE: When using the SC40Ge with SATA Hard Drives, 1.5G SATA Hard Drives are required. |
449363-B21 | |
| Step 4: Choose Additional Options for Factory Integration | ||
| NOTE:
For additional options, please refer to the "Core Options and Additional
Options" section below. NOTE: Some options may not be factory integratable. Please contact your local sales representative for additional information. |
|
|
Core Options
| NOTE: Some options may not be factory integratable. Contact your local sales representative for additional information. | ||
| Unique Options |
DL120 G5 HP Lights Out 100c Kit |
469085-B21 |
| NOTE: This remote management card supports the DL120 G5 server only. | ||
|
| ||
|
Memory (DIMMs) |
2 GB Unbuffered PC2-6400 ECC DIMM (1 x 2 GB) |
450260-B21
|
| 1 GB Unbuffered PC2-6400 ECC DIMM (1 x 1 GB) |
450259-B21
|
|
| 512 MB Unbuffered PC2-6400 ECC DIMM (1 x 512 MB) |
450258-B21
|
|
|
|
||
|
Optical Drives |
HP Slim 12.7mm SATA DVD-ROM Optical Kit | 481041-B21 |
| HP Slim 12.7mm SATA DVD-RW Optical Kit | 481043-B21 | |
|
|
||
| Hard Drives | NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the HBA or Controller. Refer to the HBA or Controller technical specifications for details. | |
| SATA Non-Hot Plug Midline (MDL) Drives | ||
| HP 750GB 3G SATA 7.2K NHP 3.5" MDL HDD | 462595-B21 | |
| HP 500GB 3G SATA 7.2K NHP 3.5" MDL HDD | 458941-B21 | |
| HP 250GB 3G SATA 7.2K NHP 3.5" MDL HDD | 458939-B21 | |
| SATA Non-Hot Plug Entry (ETY) Drives | ||
| HP 160GB 3G SATA 7.2K NHP 3.5" ETY HDD | 458947-B21 | |
| NOTE: SATA hard
drives have a 1-year warranty. Please see the QuickSpecs for Technical Specifications
and additional information: http://h18000.www1.hp.com/products/quickspecs/11940_na/11940_na.html | ||
| SAS Non-Hot Plug 3.5" Enterprise (ENT) Drives | ||
| HP 400GB 3G SAS 10K 3.5" DP NHP
ENT HDD | 508232-B21 | |
| HP 450GB 3G SAS 15K 3.5" DP NHP
ENT HDD | 454234-B21 | |
| HP 300GB 3G SAS 15K 3.5" DP NHP
ENT HDD | 417950-B21 | |
| HP 300GB 3G SAS 15K 3.5" SP NHP
ENT HDD | 431950-B21 | |
| HP 146GB 3G SAS 15K 3.5" DP NHP
ENT HDD | 417855-B21 | |
| HP 146GB 3G SAS 15K 3.5" SP NHP
ENT HDD | 432093-B21 | |
| HP 146GB 3G SAS 15K 3.5" SP NHP
ENT HDD | 432093-B21 | |
| HP 72GB SAS 15K 3.5" SP NHP ENT HDD | 432095-B21 | |
| NOTE: Please
see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12244_na/12244_na.html | ||
| 3.5" SATA Non-Hot Plug Drives | ||
| HP 250GB 1.5G SATA 7.2K NHP 3.5" HDD | 411276-B21 | |
| HP 160GB 1.5G SATA 7.2K NHP 3.5" HDD | 411275-B21 | |
| NOTE: The previous
generation of 1.5G SATA drives are still supported. NOTE: SATA hard drives have a 1-year warranty. Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/11940_na/11940_na.html | ||
| | ||
|
Communications | HP
NC110T PCI Express Gigabit Server Adapter NOTE: Does not support Windows 2000. |
434905-B21 |
| HP NC360T PCI Express Dual Port Gigabit Server Adapter |
412648-B21 | |
| HP
NC364T PCI Express Quad Port Gigabit Server Adapter NOTE: Does not support Windows 2000. |
435508-B21 | |
| HP NC373F PCI Express Multifunction Gigabit Server Adapter |
394793-B21 | |
| HP NC373T PCI Express Multifunction Gigabit Server Adapter |
394791-B21 | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs |
|
|
Additional Options
| Storage Controllers | NOTE: The purchase of any HBA or HP Smart Array Controller requires the purchase of the 4 Lane SAS/SATA host fan out Cable Kit. | |
| SAS Controllers | ||
| HP Internal SAS/SATA 4-Port Cable
NOTE: The purchase of any HBA or HP Smart Array Controller requires the purchase of the 4 Lane SAS/SATA host fan out Cable Kit. | 457692-B21 | |
| Smart Array E200 Controller | ||
| HP Smart Array E200/128 BBWC Controller | 411508-B21 | |
| 128-MB BBWC (Battery-Backed Write
Cache) Enabler NOTE: Supports the Smart Array E200 Controller, Smart Array 641 Controller, and Smart Array 642 Controller. |
351580-B21 | |
| Smart Array E500 Controller | ||
| HP Smart Array E500/256MB Controller |
435129-B21 | |
| Battery-backed
write cache upgrade NOTE: Battery only. |
383280-B21 | |
| 512MB Battery-backed cache upgrade |
405148-B21 | |
| NOTE:
Please see the following QuickSpecs for Technical Specifications and additional
information: http://h18000.www1.hp.com/products/quickspecs/12460_na/12460_na.html (Smart Array E200 Controller) http://h18000.www1.hp.com/products/quickspecs/12700_na/12700_na.html (Smart Array E500 Controller) | ||
| HP Smart Array P800/512MB BBWC Controller | 381513-B21 | |
| HP SA-P400 and SA-E500 24 In Battery Cable Kit | 417836-B21 | |
| NOTE: This option kit contains a 24" battery cable and adhesive material for installing a battery into the server if a Smart Array E500 is integrated outside of the factory. For all solutions, please refer to the server QuickSpecs and User's Manual for detailed installation instructions. | ||
| SAS HBA | ||
| NOTE: The purchase of any HBA or HP Smart Array Controller requires the purchase of the 4 Lane SAS/SATA host fan out Cable Kit. (P/N 457692-B21) | ||
| HP SC44Ge Host Bus Adapter |
416096-B21 | |
| NOTE: When using
the SC44Ge with SATA Hard Drives, 1.5G SATA Hard Drives are required. Transfer
rate: 1.5 Gb/s SATA, 3 Gb/s SAS. NOTE: Please see the following QuickSpecs for Technical Specifications and additional information: http://h18004.www1.hp.com/products/quickspecs/12617_na/12617_na.html (SC44Ge HBA) | ||
| SCSI Controllers NOTE: The HP ProLiant DL320 G5p PCI-X Riser Board Option Kit (P/N 450341-B21) is required for all PCI -X Controllers. This option is compatible with the DL120 G5. | ||
| PCI-X Riser Board |
450341-B21 | |
| SCSI HBA | ||
| HP SC11Xe Host Bus Adapter |
412911-B21 | |
| HP Internal SAS/SATA 4-Port Cable | 457692-B21 | |
| NOTE:
Please see the following QuickSpecs for Technical Specifications and additional
information: | ||
|
| ||
|
Tape Drives |
NOTE: For the complete listing of Tape
Drive offerings, please see: |
|
| USB Rack-Mount Tape Solutions | ||
| HP StorageWorks 1U USB Rack-Mount Kit with one DAT 160 USB Tape Drive |
AG703A
|
|
| SAS Rack-Mount
Tape Solutions NOTE: HP recommends purchasing the HP SC44Ge HBA (416096-B21) for a dedicated SAS HBA for tape. |
||
| HP StorageWorks LTO-2 Ultrium
448 SAS Internal Tape Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A) |
DW085A
|
|
| SCSI Rack-Mount
Tape Solutions NOTE: SCSI Controller required. HP recommends purchasing the HP SC11Xe HBA (412911-B21) for a dedicated SCSI HBA for tape. |
||
| HP
StorageWorks 1U SCSI Rack-mount kit with one LTO-2 Ultrium 448 SCSI Tape
Drive (Carbonite) NOTE: Pre-configured with one LTO-2 Ultrium 448 SCSI tape drive. |
DW028B
|
|
|
|
||
|
Disk-Based Backup | RDX Removable Disk Backup | |
| HP StorageWorks RDX160 External
Removable Disk Backup System NOTE: 160GB of Disk Storage. | AJ766A | |
| HP StorageWorks RDX320 External
Removable Disk Backup System NOTE: 320GB of Disk Storage. |
AJ768A | |
|
HP StorageWorks RDX500 External Removable Disk Backup System NOTE: 500GB of Disk Storage. | AJ935A | |
| NOTE: Please
see the HP RDX Removable Disk Backup System QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13036_na/13036_na.html | ||
| D2D Backup | ||
| HP StorageWorks D2D120 Backup
System with Data Protector Express Software Kit NOTE: 2TB of Disk Storage. |
EH924A | |
| HP
StorageWorks D2D130 Backup System with LTO-3 Ultrium 920 SAS Tape Drive NOTE: 3TB of Disk Storage. |
EH952A | |
| HP
StorageWorks D2D2503i Backup System NOTE: 3TB of Disk Storage. | EH945A | |
| NOTE: Please see the HP D2D Backup Systems QuickSpecs for additional information: http://www.hp.com/go/d2d | ||
| | ||
|
StorageWorks Options | NOTE:
The following is a list of all Fibre Channel Host Bus Adapters for Windows and
Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html | |
| HP StorageWorks 81E 8Gb Single
Port PCI-e FC HBA | AJ762A | |
| HP StrorageWorks 82E 8Gb Dual
Port PCI-e FC HBA | AJ763A | |
| HP StorageWorks 82Q 8Gb Dual
Port PCI-e FC HBA | AJ764A | |
| HP StorageWorks 81Q Single Port
PCI-e FC HBA | AK344A | |
| HP StorageWorks FC2142SR 4Gb
PCI-e HBA | A8002A | |
| HP StorageWorks FC2242SR Dual
Channel 4 Gb PCI-e HBA | A8003A | |
| HP StorageWorks FC1142SR 4Gb
PCI-e HBA | AE311A | |
| HP StorageWorks FC1242SR Dual
Channel 4 Gb PCI-e HBA | AE312A | |
| HP
StorageWorks FC2143 4Gb PCI-X 2.0 -to-Fibre Channel HBA | AD167A | |
| HP
StorageWorks FC2243 Dual Channel 4Gb PCI-X 2.0 HBA | AD168A | |
| HP
StorageWorks FC1143 4Gb PCI-X 2.0 HBA | AB429A | |
| HP StorageWorks FC1243 Dual Channel 4Gb PCI-X 2.0 HBA | AE369A | |
| | ||
|
HP StorageWorks 50 Modular Smart Array | HP
StorageWorks 50 Modular Smart Array |
364430-B21 |
| NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12245_na/12245_na.html | ||
|
| ||
|
HP StorageWorks 60 Modular Smart Array | HP StorageWorks 60 Modular Smart Array Enclosure |
418408-B21 |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12627_na/12627_na.html | ||
|
HP StorageWorks 70 Modular Smart Array | HP StorageWorks 70 Modular Smart Array Enclosure |
418800-B21 |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12652_na/12652_na.html | ||
|
Uninterruptible Power Systems – Rack | HP UPS R1500 G2 | |
| HP, R1.5kVA UPS, 1U |
AF419A | |
| NOTE:
Please see QuickSpecs Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12507_na/12507_na.html | ||
| HP UPS R3000 Uninterruptible Power System | ||
| HP R3000 VA UPS, 2U, L5-30 |
AF422A | |
| HP R3000 VA UPS, 2U, L6-20 |
AF423A | |
| NOTE:
Please see QuickSpecs Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/10671_na/10671_na.html | ||
| HP UPS R5500 Uninterruptible Power System | ||
| HP R5500 VA UPS | AF426A | |
| NOTE: Please
see QuickSpecs Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/11871_na/11871_na.html | ||
| | ||
|
HP Monitored Power Distribution Unit (PDU) |
HP Monitored Power Distribution Unit: Full Rack Version | |
| HP 17.3 kVA S2324 Monitored PDU- dual input, 3Ø, 24A |
AF503A |
|
|
HP 8.6 kVA S1324 Monitored PDU- single input, 3Ø, 24A |
AF504A |
|
| HP 16.6 kVA S2140 Monitored PDU- dual input, 1Ø, 40A |
AF505A
|
|
| HP 8.3 S1140 Monitored PDU- single input, 1Ø, 40A | AF506A | |
| HP Monitored Power Distribution Unit: Half Rack Version | ||
| HP 17.3 kVA S348 Monitored PDU- single input, 3Ø, 48A |
AF916A
|
|
| HP 4.9 kVA S124 Monitored PDU- single input, 1Ø, 24A |
AF914A
|
|
|
|
||
|
Modular Power Distribution Units 1U/0U |
HP Modular Power Distribution
Units (mPDU), Low Volt Model, 24A (100-127 VAC) NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of the UPS R3000 XR. |
252663-D71 |
|
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC) |
252663-D72 |
|
| HP Modular Power Distribution
Units (mPDU), High Volt Model, 40A (200-240 VAC) NOTE: This mPDU (252663-B21), 40A model has a hardwired input. |
252663-B21 | |
| HP Modular Power Distribution
Units (mPDU), High Volt Model, 16A (200-240 VAC) NOTE: This PDU has a detachable input power cord and allows for adaptability to country specific power requirements. |
252663-B24 | |
| NOTE: Please see
the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables and country specific
power cords: http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html NOTE: For additional information on HP Power Distribution Units including accessories please go to: www.hp.com/go/pdu. |
||
|
|
||
| USB Options | USB 1.44-MB External Diskette Drive (Carbonite) | DC141B |
| HP 1GB USB 2.0 Floppy Drive Key | 442085-B21 | |
|
|
||
| ProLiant DL120 Deployment Options | Rack
Adapter Kit NOTE: This kit allows HP rack servers to fit in racks that are 24" wide. | 332815-B21 | |
| HP
Rack 5000 Series (Metallic Carbonite) | HP 5642 Rack-Unassembled |
358254-B21 |
| NOTE:
Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.html NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
| HP Rack 10000 Series (Graphite Metallic) | HP
S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22 |
| NOTE:
xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom
systems, VARs and Channels). NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. | ||
| NOTE:
Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html | ||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
|
HP Rack 10000 G2 Series (Graphite Metallic) | 10642 G2 (42U) Rack Cabinet – Pallet |
AF001A |
| 10642 G2 (42U) Rack Cabinet – Shock Pallet |
AF002A | |
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Pallet | AF038A | |
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Shock Pallet | AF034A | |
| 10642 G2 (42U) Rack Cabinet – Crated | AF003A | |
| 10642 G2 (42U) Rack Cabinet, with Extension – Shock Pallet |
AF004A | |
| 10636 G2 (36U) Rack Cabinet – Pallet |
AF011A | |
| 10636 G2 (36U) Rack Cabinet – Shock Pallet |
AF012A | |
| 10636 G2 (36U) Rack Cabinet – Crated |
AF013A | |
| 10636 G2 (36U) Rack Cabinet, with Extension – Shock Pallet |
AF014A | |
| 10622 G2 (22U) Rack Cabinet - Pallet |
AF021A | |
| 10622 G2 (22U) Rack Cabinet - Shock Pallet |
AF022A | |
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Pallet |
AF041A | |
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Shock Pallet |
AF042A | |
| 10647 G2 (47U) Rack Cabinet - Pallet |
AF031A | |
| 10647 G2 (47U) Rack Cabinet 1200mm Deep - Pallet | AF045A | |
| 10647 G2 (47U) Rack Cabinet 1200mm Deep - Shock Pallet | AF044A | |
| NOTE: Please
see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html | ||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
|
HP Rack 10000 Series (Graphite Metallic) | HP S10614 (14U) Rack Cabinet – Shock Pallet |
292302-B22 |
| NOTE:
xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by
custom systems, VARs and Channels). NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. | ||
| NOTE: Please
see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html | ||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
|
Keyboards and Monitors |
TFT7600 Rackmount Keyboard Monitor |
AG052A
|
| 1U Rackmount Keyboard with USB |
AG072A
|
|
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
|
||
|
HP KVM Switch Options |
2x1x16 IP Console Switch with Virtual Media |
AF601A
|
| 4x1x16 IP Console Switch with Virtual Media |
AF602A
|
|
| PS/2 Virtual Media Interface Adapter,
1 pack NOTE: Requires PS/2 and one USB port on server. |
AF604A
|
|
| PS/2 Interface Adapter, 1 pack |
262588-B21
|
|
| PS/2 Interface Adapter, 8 pack |
262587-B21
|
|
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x4 Console Switch |
AF611A
|
|
| PS2 Server Console Cable, 6 ft, 2 pack |
AF612A
|
|
| USB Server Console Cable, 6 ft, 2 pack |
AF613A
|
|
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
|
HP Serial Console Server Options | Server
console switch 0x2x8 | AF616A |
| Server console switch 0x2x16 | AF617A | |
| HP 16 Port Serial Console Server |
AF101A | |
| HP 48 Port Serial Console Server |
AF102A | |
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack |
AF103A | |
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack |
AF110A | |
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
| | ||
|
Service and Support Offerings | Hardware Services On-site Service | |
| 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic |
UJ252E | |
| 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
UJ253E | |
| Hardware Services Next Business Day On-Site Service | ||
| 9-Hour x 5-Day Coverage, 3 Years, Electronic |
UJ251E | |
| Installation & Start-up Services | ||
| Hardware Services 6-Hour Call to Repair On-Site Service |
UJ254E | |
| Hardware Installation, Electronic |
UJ261E | |
| NOTE: For more information, customer/resellers can contact: http://www.hp.com/hps/ |
|
|
Memory
|
HP ProLiant DL120 G5 |
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
|
Standard Memory Standard Memory Plus Optional Memory |
| NOTE: The chart below does not represent all possible configurations. For best performance, HP recommends dual-bank interleaved mode configurations. For dual-bank interleaved mode, DIMMs must be installed in both banks with equal bank capacities. |
|
Memory |
Slot | |||||
| |
DIMM_CH1_C |
DIMM_CH1_A |
DIMM_CH2_D |
DIMM_CH2_B | Mode | |
| Optional |
512 MB |
Empty |
512 MB |
Empty |
Empty | Single-bank |
| Standard |
1 GB | Empty |
1 GB | Empty |
Empty | Single-bank |
| Optional |
1 GB | Empty |
512 MB |
Empty |
512 MB |
Dual-bank interleaved |
| Standard | 2 GB | Empty | 1 GB | Empty | 1 GB | Dual-bank interleaved |
| Maximum |
8 GB | 2 GB | 2 GB | 2 GB | 2 GB |
Dual-bank interleaved |
|
Following are memory options available from HP: | |
2 GB Unbuffered PC2-6400 ECC DIMM (1 x 2 GB) |
450260-B21 |
1 GB Unbuffered PC2-6400 ECC DIMM (1 x 1 GB) |
450259-B21 |
512 MB Unbuffered PC2-6400 ECC DIMM (1 x 512 MB) | 450258-B21 |
|
|
Storage
|
1- 2 | Two SATA or SAS drive bays | |
|
A | Optical Drive Bay: Optional DVD-ROM, or DVD-RW drive |
|
Drive Support | |||
| Quantity |
Position |
| |
|
Removable Media | |||
| 12.7mm IDE DVD-ROM or DVD-RW Drive | Up to 1 | A | HP embedded SATA Controller NOTE: Transfer Rate: 1.5 Gb/s SATA |
|
| |||
| SAS Non-Hot Plug 3.5" Enterprise (ENT) Drives | |||
| Quantity Supported | Position
Supported | Controller | |
| 400GB 3G SAS 10K DP 450GB 3G SAS 15K DP 300GB 3G SAS 15K DP 300GB 3G SAS 15K SP 146GB 3G SAS 15K DP 146GB 3G SAS 15K SP 72GB 3G SAS 15K SP | Up to 2 | 1-2 | HP
4 Internal Port SAS HBA SC40Ge with RAID (0,1, 1+0) NOTE: When using the SC40Ge with SATA Hard Drives, 1.5G SATA Hard Drives are required NOTE: Transfer Rate: 1.5 Gb/s SATA, 3Gb/s SAS |
|
| |||
| SATA Non-Hot Plug Midline (MDL) Drives | |||
| Quantity Supported |
Position Supported |
Controller | |
| 750GB 3G SATA 7.2K 500GB 3G SATA 7.2K 250GB 3G SATA 7.2K |
Up to 2 | 1-2 | 6 Port SATA controller with Embedded
RAID NOTE: Transfer Rate: 1.5 Gb/s SATA |
| SATA Non-Hot Plug Entry (ETY) Drives | |||
| Quantity Supported |
Position Supported |
Controller | |
| 160GB 3G SATA 7.2K | Up to 2 | 1-2 | 6 Port SATA controller with Embedded
RAID NOTE: Transfer Rate: 1.5 Gb/s SATA |
| 3.5" SATA Non-Hot Plug Drives | |||
| Quantity Supported |
Position Supported |
Controller | |
| 250GB 1.5G SATA 7.2K 160GB 1.5G SATA 7.2K |
Up to 2 | 1-2 | 6 Port SATA controller with Embedded
RAID NOTE: Transfer Rate: 1.5 Gb/s SATA |
|
|
|||
|
External Storage | |||
| Quantity |
Position |
Host Controller or Adapter | |
| 50 Modular Smart Array |
Up to 4 |
External | HP Smart Array E500/256MB Controller |
| Up
to 4 | HP Smart Array P800/512MB BBWC Controller | ||
| 60 Modular Smart Array Enclosure | Up
to 8 Up to 8 |
External | HP
Smart Array E500/256MB Controller HP Smart Array P 800/512MB BBWC Controller |
| 70 Modular Smart Array Enclosure | Up
to 4 Up to 4 |
External | HP
Smart Array E500/256MB Controller HP Smart Array P 800/512MB BBWC Controller |
| | |||
| Maximum Storage Capacity – (SAS drives) | |
| Internal | 900GB (2 x 450GB SAS) |
| External | 6.30TB (1 x (14 x 450GB SAS)) |
| Total | 7.20TB |
| NOTE: The External capacity section relates to the HP StorageWorks 20 Modular Smart Array. | |
|
| |
| Maximum Storage Capacity – (SATA Drives) | |
| Internal | 1.5TB (2 x 750GB SATA) |
| External | 9.0TB [1 x (12 x 750GB SATA)] |
| Total | 10.50TB |
| NOTE: In order to implement integrated SATA RAID with Support CD on Windows 2000/2003, the use of a floppy drive is necessary. | |
| NOTE: The External capacity section relates to the HP StorageWorks 20 Modular Smart Array. | |
| | |
| Tape and Disk-Based Backup | |||
| NOTE: For a complete listing of compatible tape and disk-based backup offerings, please visit: www.hp.com/go/connect |
|
Position
Supported |
Controller
|
Controller Part Number |
|
| HP StorageWorks USB Tape
DAT 72 USB DAT 160 USB 1U USB Rack-Mount Kit |
External
|
USB 2.0 Port |
N/A
|
| HP StorageWorks
SAS Tape Drives, External LTO-2 Ultrium 448 SAS 1U Rack-Mount Kit |
External | HP SC44Ge Host Bus Adapter | 416096-B21 |
| HP StorageWorks SCSI Tape Ultrium 448 DAT 72 DAT 160 1U SCSI Rack-Mount Kit |
External
|
HP SC11Xe Host Bus Adapter |
412911-B21
|
| HP StorageWorks RDX Removable
Disk Backup System RDX160 RDX320 |
External
|
USB 2.0 Port | N/A |
| HP StorageWorks D2D Backup
Systems D2D120 D2D130 D2D2503i |
External
|
Embedded Network Controller |
N/A
|
|
|
Technical Specifications
|
System Unit | Dimensions
(H x W x D) (with bezel) |
1.69 x 17.64 x 27.5 in (4.30 x 44.80 x 69.85 cm) | |
|
Weight |
Maximum | 32.40 lb (14.70kg) | |
| Minimum
(one hard drive, power supply, and processor installed) | 31.00lb (14.00kg) | ||
|
Input Requirements |
Range Line Voltage | 90
- 132 VAC, | |
|
Rated Input Current | 6
A (at 100 VAC), | ||
|
Rated Input Frequency |
47 to 63 Hz | ||
| Rated Input Power | <500W @115/230 VRMS (For frequency only) | ||
| BTU Rating | Maximum | 1194 BTU/hr (at 115/230 VRMS) | |
| Power Specifications | To
review typical system power ratings use the Power Advisor which is available via
the online tool located at URL: www.hp.com/go/proliant-energy-efficient. -
Click on the system of interest. Example: DL120 G5 | ||
|
Power Supply Output |
Rated Steady-State Power |
350 W (at 115/230 VRMS), | |
| Maximum Peak Power | 350 W (at 115/230
VRMS), 350 W (at 115/230 VRMS) | ||
| System Inlet Temperature | Operating |
10° to 35°C (50° to 95°F) at sea level with an altitude derating
of 1.0°C per every 300 m (1.8°F per every 1000 ft) above sea level to
a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of
change is 10°C/hr (18°F/hr). The upper limit may be limited by the type
and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). | |
|
Non-operating | -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). | ||
| Relative Humidity (non-condensing) | Operating | 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. | |
| Non-operating | 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. | ||
|
Altitude | Operating | 3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | |
| Non-operating | 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | ||
|
Acoustic Noise |
Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). | ||
| Idle | |||
| 6.26 B | ||
| 43.8 dBA | ||
| Operating | |||
| 6.28 B | ||
|
44.5 dBA | ||
| Emissions Classification (EMC) | FCC Rating | Class A | |
| Normative Standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 | ||
|
NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements. | |||
| | |||
|
Power Supply |
Input voltage specifications |
Rated input voltage |
100 VAC to 240 VAC |
|
Input Specifications |
Rated input line |
90 VAC to 264VAC |
|
|
Frequency range |
47 to 63 Hz |
||
|
Rated input power |
@ 115V input, Rated input power = 500W (assume output wattage=350W |
||
|
Rated input current |
6 A, 3 A (110 V, 220 V) |
||
|
Steady state power |
350W (rated) |
||
| BTU Rating | 1710 BTU/hr | ||
| Ambient temperature range | Operating | 50° to 118° F (10° to 48° C) | |
| Non-operating | -40° to 158° F (-40° to 70° C) | ||
|
Relative humidity |
Operating |
55% to 85% | |
| Non-operating | 5% to 95% | ||
| Dielectric voltage withstand | Input to output | ||
| Input to ground | |||
| Maximum Wet Bulb Temperature | 106.3° F (41.3° C) | ||
|
|
|||
|
Integrated Serial ATA Controller | Simultaneous drive transfer channels | 4 channels |
| Transfer
rate synchronous (maximum theoretical) | 150 MB/s per channel; 300 MB/s in RAID 0 pair | |
| Data transfer method | Intel®
82801IR Integrated Serial ATA Host Controller (non-RAID mode) Intel® 82801IR Integrated Serial ATA Host Controller (RAID Mode) | |
| Drive support | Serial ATA | |
| Data transfer modes | Legacy
Mode Combined Mode | |
| Protocol | Serial ATA | |
| Feature | NCQ (Native Command Queuing); AHCI (Advanced Host Controller Interface) | |
| RAID levels supported | 0, 1 | |
| RAID Features | Supports
multiple logical volumes Setup through ROM based Array Configuration Utility Installation scripting support NOTE: This controller does not support Hot Plug functions or LED functions. | |
| RAID OS Support | Microsoft
Windows Server 2003 NOTE: In order to implement integrated SATA RAID with Smart Start 7.90 on Windows 2000/2003, the use of a floppy drive is necessary. Linux (Red Hat, SuSE, UnitedLinux) |
|
|
| ||
|
Embedded NC105i PCIe Gigabit Server Adapter |
Network Interface | 10Base-T/ 100Base-TX/ 1000Base-TX |
|
| Combines a triple-speed IEEE 802.3TM - Compliant Media Access Controller (MAC) with a triple-speed Ethernet transceiver. | |||
| Compatibility | IEEE 802.3 10Base-T | ||
| IEEE 802.3ab 1000Base-T | |||
| IEEE 802.3u 100Base-TX | |||
| Data Transfer Method | Four lane (x4), 100MHz PCI Express Reference Clock | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000Mb/s | ||
| Connector | RJ-45 connector | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP; up to 328 ft (100 m) | |
| 10/100/1000Base-TX | Category 5 UTP; up to 328 ft (100 m) | ||
|
|
|||
|
Environment-friendly Products and Approach | End-of-life Management and Recycling | Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
| | ||
|
© Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less. |