Overview
|
HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem |
| Simplify and make your data center change-ready. The HP Virtual Connect Flex-10 10Gb Ethernet Module for the c-Class BladeSystem is the simplest, most flexible connection to your networks. The Virtual Connect Flex-10 Ethernet Module is a new class of blade interconnect that simplifies server connections by cleanly separating the server enclosure from LAN, simplifies networks by reducing cables without adding switches to manage, allows you to change servers in just minutes, not days, and tailors network connections and speeds based on application needs. HP Flex-10 technology significantly reduces infrastructure costs by increasing the number of NICs per connection without adding extra blade I/O modules, and reducing cabling uplinks to the data center network. The HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem is an innovative, new class of integrated interconnects from HP. |
![]() |
|||
|
Figure 1 Virtual Connect Ethernet Module
Front Bezel
|
|||
| 1. | Module locator UUID | 6. | Link indicator |
| 2. | Module status indicator | 7. | Active mulitplexed port indicator |
| 3. | 10Gb CX4 Backlit port number and status indicator | 8. | Backlit port number and status indicator LED |
| 4. | 10Gb CX4 link indicator | 9. | Backlit port number and status indicator LED |
| 5. | Link indicator | 10. | Active mulitplexed port indicator |
|
|
|||
| What's New |
|
|
|
| At A Glance |
|
Performance
Management
Virtual Connect Server Profiles
Options
|
|
|
| Models | |
| HP Virtual Connect Flex-10 10Gb Ethernet Module for the c-Class BladeSystem |
455880-B21
|
|
|
Supported Products
| Compatibility | |||
| HP ProLiant Servers and Network options | The HP BladeSystem c-Class Virtual Connect Firmware v2.X supports the following hardware. For the HP Virtual Connect Manager Release Notes and Compatibility Matrix and the full listing of recommended and minimum firmware versions, see the HP website. | ||
For optimal operation of HP Virtual Connect Manager, use the following recommended firmware version for the Onboard Administrator and iLO. |
|||
| Virtual Connect Firmware version | Onboard Administrator | iLO | |
| VC 2.0 | For c7000 Enclosure, recommended
version 2.25 or higher For c3000 Enclosure, recommended version 2.25 or higher |
ProLiant: Recommended version
1.6 or higher Integrity: Recommended version T.02.17 or higher |
|
| For the HP Virtual Connect Manager Release Notes and Compatibility Matrix and the full listing of recommended and minimum firmware versions, see the HP website. | |||
| ProLiant BL c-Class Server Blade Enclosures |
|
||
|
|
|||
| Supported Configurations | |||
![]() |
|||
|
HP BladeSystem c7000 Enclosure - Rear
View
|
|||
| 1. | Upper Fan System | 5. | Interconnect Bays 7 / 8 |
| 2. | Interconnect Bays 1 /2 | 6. | On Board Administrator |
| 3. | Interconnect Bays 3 / 4 | 7. | Lower Fan System |
| 4. | Interconnect Bays 5 / 6 | 8. | Rear Redundant Power Complex |
|
|
|||
![]() |
|||
|
HP BladeSystem c3000 Enclosure - Front
View
|
|||
| 1. | Device Bays 1 thru 8 | 4. | Insight Display |
| 2. | Enclosure DVD Drive | 5. | Active Onboard Administrator |
| 3. | Standby Onboard Administrator (reserved for Future) | ||
|
|
|||
![]() |
|||
|
HP BladeSystem c3000 Enclosure - Rear
View
|
|||
| 1. | Local KVM interface (reserved for future) | 7. | iLO/Onboard Administrator Port |
| 2. | Interconnect Bay 1 | 8. | iLO/Onboard Administrator Port 2 (reserved for future) |
| 3. | Active Cool Fans | 9. | Power Supplies |
| 4. | Interconnect Bay 2 | 10. | Interconnect Bay 4 |
| 5. | Enclosure Up-link and Service Port | 11. | Interconnect Bay 3 |
| 6. | Enclosure Down-link | ||
|
|
|||
|
Mezzanines
|
|
| c-7000 Port Mapping | Port mapping differs slightly
between full height and half height server blades due to the support for
additional Mezzanine cards on the full height version. HP has simplified the processes of mapping Mezzanine ports to switch ports by providing intelligent management tools via the Onboard Administrator and HP Insight Manager Software. The Onboard Administrator Guide, Enclosure Setup and Installation Guide provides detailed information on port mapping. |
![]() |
![]() |
|
Half Height Server Blade
|
Full Height Sever Blade
|
|
|
|
| c-3000 Port Mapping | Port mapping differs slightly
between full height and half height server blades due to the support for
additional Mezzanine cards on the full height version. HP has simplified the processes of mapping Mezzanine ports to switch ports by providing intelligent management tools via the Onboard Administrator and HP Insight Manager Software. The Onboard Administrator Guide, Enclosure Setup and Installation Guide provides detailed information on port mapping. |
![]() |
![]() |
|
Half Height Server Blade
|
Full Height Sever Blade
|
| The following are supported configurations for the Virtual Connect Flex-10 Ethernet Module. Please note that other interconnect options can be installed in the enclosure, but they do not inherit the benefits of Virtual Connect. Switches and Pass-Thru modules will operate per their default configurations. Any moves, adds, or changes to servers which are connected to non-Virtual Connect modules will require reconfiguration on the LAN and/or SAN. The Virtual Connect Manager will only manage Virtual Connect Modules. | |
|
|
|
|
HP BladeSystem c7000 Enclosure
|
||||||||
| NOTE: The following tables show a number of typical, supported configurations for an HP BladeSystem c7000 Enclosure. | ||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
| * This configuration is only applicable for enclosures with full-height servers. | ||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
||||||||
|
|
||||||||
|
HP BladeSystem c3000 Enclosure
|
||||
| NOTE: The following tables show a number of typical, supported configurations for an HP BladeSystem c3000 Enclosure. | ||||
|
||||
|
||||
|
||||
|
||||
|
|
||||
| Required Cabling |
10GBASE-CX4 |
Twinax CX4 (0.5 to 15m) | ||
| NOTE: For available cables; please see the "Options" section below of this QuickSpecs. | ||||
| Maximum Distances | Multimode OM1 62.5/125 micron |
Multimode OM2 50/125 micron |
Multimode OM3 50/125 micron |
Singlemode 9 micron |
| SR | 2 - 26m/33m* | 2 - 82m | 2 - 300m | |
| LR | 2 -10km | |||
| LRM | 0.5 - 220m | 0.5 - 220m | 0.5 - 220m | |
| * 26m
at 160MHz and 33m at 200MHz. NOTE: For additional information on 10Gb cable specifications go to: http://www.hewlett-packard.com/rnd/pdfs/10gig_cabling_ technical_brief.pdf |
||||
|
|
||||
| Stacking Configuration |
Stacking links are used to interconnect Virtual Connect Ethernet Modules
when using more than one enclosure or when using more than two Virtual
Connect Ethernet Modules in a single enclosure. |
|
|
|
![]() |
|
|
Service and Support, HP Care Pack and Warranty Information
| Service and Support |
This product is covered by a global limited warranty and supported by
HP Services and a worldwide network of HP Authorized Channel Partners.
Hardware diagnostic support and repair is available for three years from
date of purchase. Support for software and initial setup is available
for 90 days from date of purchase. Additional support may be covered under
the warranty or available for an additional fee. Enhancements to warranty
services are available through HP Care Pack services or customized service
agreements.
Enhanced Service - Optimize service level to increase IT performance and availability
Installation & Start-Up service for HP BladeSystem Infrastructure
plus HP BladeSystem Enhanced Network Installation and Start-UP as per
the Customer Description and/or Data Sheet. To be delivered on a scheduled
basis 8am-5pm, M-F, excluding HP holidays. |
|
|
Related Options
| Cabling and Transceiver Options | HP .5m 10GbE CX4 Cable | 444477-B21 |
| HP 1m 10GbE CX4 Cable | 444477-B22 | |
| HP 3m 10GbE CX4 Cable | 444477-B23 | |
| HP 15m 10GbE CX4 Cable | 444477-B27 | |
| HP 0.5m SFP+ 10GbE Copper Cable | 487649-B21 | |
| HP 1m SFP+ 10GbE Copper Cable | 487652-B21 | |
| HP 3m SFP+ 10GbE Copper Cable | 487655-B21 | |
| HP 5m SFP+ 10GbE Copper Cable | 537963-B21 | |
| HP 7m SFP+ 10GbE Copper Cable | 487658-B21 | |
| HP BladeSystem 10Gb SR SFP+ | 455883-B21 | |
| HP BladeSystem 10Gb LR SFP+ | 455886-B21 | |
| HP BladeSystem 10Gb LRM SFP+ | 455889-B21 | |
| HP BladeSystem 1Gb SX SFP Opt Kit | 453151-B21 | |
| HP BladeSystem 1Gb RJ-45 SFP Opt Kit | 453154-B21 | |
| HP 2 m LC-LC Multi-Mode OM2 Fiber Optic Cable | 221692-B21 | |
| HP 5 m LC-LC Multi-Mode OM2 Fiber Optic Cable | 221692-B22 | |
| HP 15 m LC-LC Multi-Mode OM2 Fiber Optic Cable | 221692-B23 | |
| HP 30 m LC-LC Multi-Mode OM2 Fiber Optic Cable | 221692-B26 | |
| HP 50 m LC-LC Multi-Mode OM2 Fiber Optic Cable | 221692-B27 | |
| HP .5 m LC-LC Multi-Mode OM3 Fiber Optic Cable | AJ833A | |
| HP 1 m LC-LC Multi-Mode OM3 Fiber Optic Cable | AJ834A | |
| HP 2 m LC-LC Multi-Mode OM3 Fiber Optic Cable | AJ835A | |
| HP 5 m LC-LC Multi-Mode OM3 Fiber Optic Cable | AJ836A | |
| HP 15 m LC-LC Multi-Mode OM3 Fiber Optic Cable | AJ837A | |
| HP 30 m LC-LC Multi-Mode OM3 Fiber Optic Cable | AJ838A | |
| HP 50 m LC-LC Multi-Mode OM3 Fiber Optic Cable | AJ839A | |
|
|
||
| Service and Support Offerings |
NOTE: The HP Care Pack service part numbers below for ProLiant BL c-Class server blades, cover the server blade and all HP branded hardware options qualified for the server, purchased at the same time or afterwards, internal to the server. |
|
| Hardware Services On-site Service |
|
|
| 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic |
UE458E
|
|
| 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
UE459E
|
|
| 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
UE460E
|
|
| NOTE: HP Care Pack services for the c7000 and c3000 Enclosures cover the enclosure, power supplies and fans. HP qualified rack options are covered by these services when installed within the same rack. HP supported c-Class enclosure devices including pass thru, Ethernet interconnect and virtual connect modules are also covered by the c7000 and c3000 enclosures Care Pack services. | ||
| NOTE: SAN/Fabric switches for the HP c-Class BladeSystem are not covered under the c7000 and c3000 enclosures Care Packs, SAN/Fabric switches carry separate Care Packs. SAN/Fabric Switch Care Pack service level support should always be uplifted to match existing storage or server service level. | ||
| Hardware Services On-site Service | ||
| Next Business Day On-site Service,
5-Day x 9-Hour Coverage, 3 Years, Electronic NOTE: Uplifts the Ethernet devices to the same level of service as the c-class enclosure. |
UE477E
|
|
| 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic |
UE478E
|
|
| 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
UE479E
|
|
| 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
UE480E
|
|
| Installation & Start-up Services | ||
| Hp BladeSystem c-Class Infrastructure Installation and Startup Service, Electronic |
UE602E
|
|
| HP BladeSystem Enhanced Network Installation and Startup Service, Electronic |
UE603E
|
|
| ProLiant BL c-Class Blade Server Hardware Installation, Electronic |
UE493E
|
|
| ProLiant BL c-Class Enclosure and Server Blade Hardware Installation, Electronic |
UE494E
|
|
| NOTE: For additional information; please visit: http://www.hp.com/services/bladesystemservices |
|
|
Technical Specifications
| Shipping Dimensions |
Length |
13.88 in (352.55 mm) |
|
| Width | 10.63 in (270.00 mm) | ||
| Height | 4.75 in (120.65 mm) | ||
| Shipping Weight |
4.4 lbs (2.0 Kg) |
||
| Product Specifications Hardware | Performance
|
Line Rate, full-duplex 240Gbps bridging fabric | |
| Non-blocking architecture | |||
| Maximum transmission unit (MTU) of up to 9216 bytes (jumbo frames) | |||
| Connectors and Cabling | 16 x 10Gb downlinks
midplane 2 x 10Gb cross connect 1 x 10Gb copper uplinks CX-4 8 x 10Gb SR, LR, or LRM fiber uplinks SFP+ 1 management USB port 1 internal interface to c-Class Onboard Administrator Module |
||
| Indicators | Recessed Momentary
Reset Switch Momentary Next/Step Switch Backlit port number and status indicator LED, one per bulkhead port, blue/amber/green Module status indicator, amber/green Module locator (UID), blue Link indicator, one per CX4-port, green Link indicator, one per SFP+-port, green/amber USB port (covered) Active multiplexed port indicator, green |
||
| Dimensions | Length | 10.5 in (267.7 mm) | |
| Width | 7.5 in (92.79 mm) | ||
| Height | 1.1 in (27.94 mm) | ||
| Weight | 1.27Kg (2.8 Lbs) | ||
| Environmental Ranges | Temperature Range | ||
| Specification | 10C to 35C (50F to 95F) | ||
| Temperature Range* | |||
| Operating | 10C to 35C (50F to 95F) | ||
| Shipping | Shipping -40C to 60C (-40F to 140F) | ||
| Storage | -20°C to 60°C (-4F to 140°F) | ||
| Maximum wet bulb temperature | 30C (80F) | ||
| Relative Humidity (noncondensing)** | |||
| Operating | 10% to 90% | ||
| Shipping | 10% to 90% | ||
| Storage | 10% to 95% | ||
| * All temperature
ratings shown are for sea level. An altitude derating of 1°C per 304.8
m (1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct
sunlight allowed. Upper operating limit is 3,048m (10,000 ft) or 70 Kpa/10.1
psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia. ** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa. |
|||
| Power Specification | 12V @ 8.75A (105 W) | ||
|
|
|||
| Product Specifications Software | Security Features
|
Private VLAN's for secure connectivity between servers within a domain |
| Trunking and Failover Features | Shared Uplink Sets using
Link Aggregation Control Protocol (LACP) allows the creation of Ethernet
channeling with upstream switches that conform to IEEE 802.3ad. Ports can
alternatively be configured for failover only. External ports within a Port Set can be on the same VC Ethernet module or on multiple VC modules within the VC domain. In the event of an uplink failure to a data center switch, the next highest performance uplink connection or aggregation will become active. Fast MAC Cache failover enables rapid recovery of network connections when a standby module becomes active. Smart Link network senses a failed upstream switch connection and allows teamed NICs to properly failover. Configure uplink speeds to Auto, 1Gb,or10Gb on the associated uplinks |
|
| VLAN Features | 802.1Q VLAN supported
on uplinks. Uplink ports can be configured for VLAN tagging at egress or pass-thru of tagged VLAN packets from Server ports. Native VLAN support for untagged packets on a shared uplink set. Packets can be targeted to a specific server ports. |
|
| Management Features |
Simple and intuitive Graphical User Interface (GUI) for defining, configuring,
and managing all elements of the Virtual Connect Domain. |
|
|
|
||
| Management and Standards Support | Standards |
802.1AB LLDP |
|
|
||
| Safety and Compliance |
Safety Certifications |
UL/CUL Recognition to UL/CSA 60950-1 |
| TUV to EN 60950-1 | ||
| CB report and certificate to IEC 60950-1 with all country deviations | ||
| CE Marking | ||
|
|
||
| Electromagnetic Emissions Certifications FCC Part 15 Class A | FCC Part 15 Class A |
| EN 55022 Class A (CISPR22 Class A) | |
| VCCI Class A | |
| AS/NZS 3548 Class A or AS/NZS CISPR22 Class A | |
| MIC Class A | |
| CE Marking | |
|
|
|
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go
to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will
be recycled, recovered or disposed of in a responsible manner. |
|
|
||
|
© Copyright 2009 Hewlett-Packard Development Company,
L.P. |