Overview
|
HP ProLiant DL165 Generation 5p (G5p) | |||
|
Hot Plug SAS/SATA or Non-Hot Plug SATA Models
| |||
![]() | ![]() | ||
| Front View: | Rear View: | ||
| 1. | Access panel | 1. | Power supply cable socket |
| 2. | Memory banks | 2. | PS/2 mouse port |
| 3. | Two (2) AMD Opteron 2300 series processors | 3. | PS/2 keyboard port |
| 4. | Power supply | 4. | Two (2) RJ45 GbE LAN ports |
| 5. | PCI-E expansion riser | 5. | Rear panel USB 2.0 ports |
| 6. |
System fans
| 6. | Lights-Out 100 10/100Mbps port |
| 7. | Optical drive bay | 7. | Video port |
| 8. | Front-panel USB 2.0 ports | 8. | Serial port |
| 9. | Power switch/system status LEDs | 9. | Low-profile slot cover (slot only accessible in G5 system) |
| 10. | Optional 3rd and 4th 3.5" hot-plug SAS/SATA or non-hot plug SATA hard drive bays | 10. | Full-sized riser board assembly slot cover |
| 11. | Standard 1st and 2nd 3.5" hot-plug SAS/SATA or non-hot plug SATA hard drive bays | ||
| 12. | Full height/full length PCI-Express or HTX slot | ||
| What's New |
|
|
|
| At A Glance |
|
Introducing the HP ProLiant DL165G5p, now available with the latest high performance Opteron Quad Core processors, increased storage by 2X and a new high efficiency power supply option.
|
|
|
Standard Features
|
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | |
|
Processor | AMD Opteron™ processor Model 2393SE (3.1GHz, 105W ACP) |
| AMD Opteron™ processor Model 2389 (2.9GHz, 75W ACP) | |
| AMD Opteron™ processor Model 2384 (2.7GHz, 75W ACP) | |
| AMD Opteron™ processor Model 2381HE (2.5GHz, 55W ACP) | |
| AMD Opteron™ processor Model 2380 (2.5GHz, 75W ACP) | |
| AMD Opteron™ processor Model 2377EE (2.3GHz, 50W ACP) | |
| AMD
Opteron™ processor Model 2376 HE (2.3GHz, 55W ACP) NOTE: Offered through Configure-To-Order only. See Factory Integrated Models section for more details. | |
| AMD Opteron™ processor Model 2376 (2.3GHz, 75W ACP) | |
| AMD Opteron™ processor Model 2374 HE (2.2GHz, 55W ACP) | |
| | |
| Upgradeability | Upgradeable to two processors |
|
| |
| Chipset | ServerWorks HT2100 and HT1000 |
| | |
| Cache Memory | 6MB shared L3 cache |
|
|
|
| Memory Protection | Advanced ECC |
|
| |
| Memory One of the following depending on Model |
Type | REG PC2-6400 DIMMs (DDR2-667) | |
| REG PC2-5300 DIMMs (DDR2-667) | |||
| NOTE: DIMM banks are active only when the corresponding processor socket is populated. | |||
| Standard (Model 2376) |
2 GB | (2 x 1 GB) | |
| Standard (Model 2380) |
4 GB | (2 x 2 GB) | |
| Standard (Model 2384) |
8 GB | (4 x 2 GB) | |
| Maximum | 64 GB | (16 x 4 GB) | |
|
|
|||
| Network Controller | Embedded NC362i dual-port gigabit server adapter |
|
| |
|
Expansion Slots #
|
Technology
|
Bus Width**
|
Connector Width
|
Bus Number*
|
Form Factor
|
Notes
|
|
1
|
PCI Express
|
x16
|
x16
|
3
|
Full Height/Full Length
|
|
| * Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number. | ||||||
| ** Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest Device ID by bus (starting with the lowest bus). | ||||||
|
|
||||||
| Storage Controller | Non-Hot Plug SATA | HP Embedded SATA Controller |
| Hot Plug SATA/SAS | HP SC40Ge SAS HBA with RAID
0,1 NOTE: When using the SC40Ge with SATA Hard Drives, 1.5G SATA Hard Drives are required. |
|
| NOTE: A diskette drive is needed to install storage controller drivers during a Windows operating system installation from CD. | ||
|
| ||
| Storage | Diskette Drives | Via USB only |
| Optical Drives | Optional 8x IDE (ATAPI) DVD-ROM drive, slim | |
| Optional 24x IDE (ATAPI) DVD-ROM/CDRW drive | ||
| Hard Drives | Up to 4 Non-hot plug SATA 3.5" drives | |
| Up to 4 Hot plug SATA /SAS 3.5" drives | ||
|
|
||
| Maximum Internal Storage | Non-Hot Plug SATA | 3.0TB | 4 x 750GB |
| Hot Plug SATA | 4.0TB | 4 x 1TB | |
| Hot Plug SAS | 4.0TB | 4 x 1TB | |
| | |||
| Interfaces | Parallel | None |
| Network RJ-45(Ethernet) | HP NC362i Integrated Dual Port Gigabit Server Adapter | |
| Serial | 1 | |
| Pointing Device (Mouse) | 1 | |
| Graphics | 1 | |
| Keyboard |
1 |
|
| USB | Up to 5 (two front & two
rear standard, 1 internal option) NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html. |
|
|
|
||
| Graphics | 32MB shared supporting 1600x1200x16M resolution |
|
| |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) |
| | |
| Remote Management | Lights-Out 100i |
HP Lights-Out 100i Remote Management delivers affordable, entry level remote management capabilities for HP ProLiant 100 Series servers with embedded LO100i. It allows customers or their service providers to remotely manage ProLiant 100 Series servers remotely over a LAN or the Internet and consists of the following:
NOTE: Flexible and volume quantity (AKA) license kits are available for the Lights-Out 100i Advanced Pack licenses as well as Electronic License To Use (E-LTU). AKA Tracking licenses require a 100 unit minimum forecast at initial contract signing. For these additional part numbers, please refer to each software products. QuickSpecs at this link for more information: www.hp.com/go/lo100 |
|
|
||
| Core Infrastructure Management | HP Insight Control for Linux |
HP Insight Control for Linux, as a product option, delivers essential
infrastructure management that can help save time and money by making
it easy to deploy, monitor, remote control, and optimize your IT infrastructure
through a single, simple management console. The Insight Control for Linux
suite installs and license software modules that are integrated into HP
System Insight Manager. |
| Insight Control server deployment | HP Insight Control server deployment
is a deployment solution for HP ProLiant and Integrity servers hosted on
a Windows CMS. It automates the process of deploying and provisioning server
software, enabling companies to quickly and easily adapt to changing business
demands. Insight Control server deployment includes software optimizations
for HP servers, including the HP scripting toolkits, configuration jobs
for leading industry-standard operating systems, sample unattended files,
and HP server support packs that include software drivers, management agents,
and important documentation. Deploying servers can be accomplished either
through imaging or through scripting. Insight Control server deployment is hosted on a Windows server and is intended for heterogeneous environments deploying Windows, Linux, VMware ESX and Microsoft Hyper-V systems. Insight Control server deployment includes one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/insight. |
|
|
|
||
| Industry Standard Compliance | ACPI V2.0 Compliant |
| PCI 2.2 Compliant | |
| PXE Support | |
| WOL Support | |
| Microsoft® Logo certifications | |
| IPMI 2.0, SMASH CLP Compliant | |
|
|
|
| Manageability |
Embedded HP ProLiant Lights-Out 100i Remote Management, with licensable upgrades to Lights-Out 100i Advanced. |
|
|
|
| Security | Power-on password |
| Setup password | |
|
|
|
| UPS and PDU Power Cord Matrix |
Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords. |
| | |
| Power Supply | 650 Watts, auto-switching, PFC (Power Factor Correcting) |
|
|
|
| System Fans | 6 system fans ship standard; non-hot plug, non-redundant |
| | |
| Operating Systems and Virtualization Software Support for ProLiant Servers |
Microsoft
Windows Server |
|
|
|
| Rack Airflow Requirements | Rack 10000 G2 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 5,350 sq cm (830 square inches) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation). Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 7 cm (2.75 inches) CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
| | |
| Rack Support | The DL Fixed Rail System supports installation in racks with square or round mounting holes (including Compaq/HP 7000, 9000, 10000 and HP series), with an adjustment range of 24" - 36". |
| | |
| Telco Rack Kit |
Installation into Telco 2 post, and 4 post, or threaded holes racks requires a 3rd party option kit. For additional information, please visit: www.hp.com/go/rackandpower. |
| | |
| HP Factory Express Capability |
HP Factory Express offers configuration, customization, integration and
deployment services for HP servers and storage products. Customers can
choose how their factory solutions are built, tested, integrated, shipped
and deployed. |
|
|
|
| HP Enterprise Configurator |
The HP eConfigure Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. |
|
|
|
| Service and Support |
HP Care Pack Services provide total care and support expertise with committed
response designed to meet your IT and business needs.
Enhanced Service - Optimize service level to increase IT performance and availability
Installation & Start-Up of a ProLiant server and Microsoft or Linux
O/S per the Customer Description and/or Data Sheet. To be delivered on
a scheduled basis 8am-5pm, M-F, excl. HP holidays. |
|
|
HPC Interconnects
| NOTE: High Performance Computing (HPC) interconnect technologies are available for the DL165 G5p under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects: http://www.hp.com/techservers/clusters/ucp/index.html | ||
|
|
||
| HPC Interconnects | InfiniBand | PCI-Express adapters |
| Gigabit Ethernet | Use embedded ports or optional 10GbE NICs | |
|
|
Models
| Non-Hot Plug Serial ATA (SATA) Models | ||
|
Entry Model |
Processor(s) |
(1) AMD Opteron™ processor
Model 2376 (2.3 GHz, 75W ACP) (1) AMD Opteron™ processor Model 2374HE (2.2 GHz, 55W ACP) |
| Cache Memory | 6MB shared Level 3 cache | |
| Memory One of the following depending on model |
2GB (2 x 1GB) Registered PC2-6400
DDR2 DIMMs (800MHz) with Advanced ECC capabilities 2GB (2 x 1GB) Low Power Registered PC2-5300 DDR2 DIMMs (667MHz) with Advanced ECC capabilities |
|
| Network Controller | HP NC362i Integrated Dual Port Gigabit Server Adapter | |
| Storage Controller | HP Embedded SATA Controller | |
| Hard Drive | (1) 160GB NHP SATA HDD | |
| Internal Storage | SATA: 3TB maximum | |
| Optical Drive | None Ships Standard (Optional DVD-ROM, DVD/CD RW) | |
| Form Factor | Rack (1U) | |
| | ||
| Hot Plug Serial ATA (SATA)/Serial Attached SCSI (SAS) Models | ||
|
Performance Model |
Processor(s) |
(2) AMD Opteron™ processor Model 2384 (2.7 GHz, 75W ACP) |
| Cache Memory | 6MB shared Level 3 cache | |
| Memory One of the following depending on model |
4GB (4 x 2GB) Registered PC2-6400
DDR2 DIMMs (800MHz) with Advanced ECC capabilities 4GB (2 x 2GB) Registered PC2-6400 DDR2 DIMMs (800MHz) with Advanced ECC capabilities |
|
| Network Controller | HP NC362i Integrated Dual Port Gigabit Server Adapter | |
| Storage Controller | HP 4 Internal Port SAS HBA with RAID | |
| Hard Drive | None ship standard (up to 4 Hot Plug SATA or SAS drives supported) | |
| Internal Storage One of the following depending on model |
SATA: 4.0TB Maximum SAS: 4.0TB Maximum |
|
| Optical Drive | None Ships Standard (Optional DVD-ROM, DVD/CD RW) | |
| Form Factor | Rack (1U) | |
|
|
Configuration Information - Factory Integrated Models
|
NOTE: This section lists some of the steps required to configure
a Factory Integrated Model. To ensure only valid configurations are ordered,
HP recommends the use of an HP approved configurator. Contact your local
sales representative for information on CTO product offerings and requirements. |
||
| Step 1: Base Configuration | ||
| Non-Hot Plug SATA Model | ||
| HP ProLiant DL165 G5p Non-Hot Plug SATA Rack Chassis |
495842-B21
|
|
| Factory Integrated Model ships with: | ||
| HP NC362i Integrated Dual Port Gigabit Server Adapter | ||
|
One available PCI-Express slots, including one full-length/full height slot |
||
| HP embedded SATA controller | ||
| 650 Watt Power Supply | ||
| 6 Fixed, Non-Redundant Fans | ||
| Rack (1U), (1.75 in / 4.45 cm) Fixed Mounting Rails |
||
| Hot Plug SATA/SAS Model | ||
| HP ProLiant DL165 G5p Hot Plug SATA/SAS Rack Chassis |
495841-B21
|
|
| Factory Integrated Model ships with: | ||
| HP NC362i Integrated Dual Port Gigabit Server Adapter | ||
| One full-length/full height PCI-Express slot houses the SATA/SAS storage controller | ||
| 650 Watt Power Supply | ||
| 6 Fixed, Non-Redundant Fans | ||
| Rack (1U), (1.75 in / 4.45 cm) Fixed Mounting Rails |
||
|
|
||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processors | AMD
Opteron™ processor Model 2393SE (3.1GHz, 105W ACP), FIO | 500062-L21 |
| AMD Opteron™ processor Model 2389 (2.9GHz, 75W ACP), FIO | 500049-L21 | |
| AMD Opteron™ processor
Model 2384 (2.7GHz, 75W ACP), FIO NOTE: If 2 processors are desired, select one 500064-L21 and one 500064-B21. | 500064-L21 | |
| AMD Opteron™ processor Model 2381HE (2.5GHz, 55W ACP), FIO | 500058-L21 | |
| AMD Opteron™ processor
Model 2380 (2.5GHz, 75W ACP), FIO |
500060-L21 | |
| AMD Opteron™ processor Model 2377EE (2.3GHz, 50W ACP), FIO | 536530-B21 | |
| AMD Opteron™ processor
Model 2376 HE (2.3GHz, 55W ACP), FIO |
507540-L21 | |
| AMD
Opteron™ processor Model 2376 (2.3GHz, 75W ACP), FIO NOTE: If 2 processors are desired, select one 500056-L21 and one 500056-B21. | 500056-L21 | |
| AMD Opteron™ processor
Model 2374 HE (2.2GHz, 55W ACP), FIO NOTE: If 2 processors are desired, select one 500051-L21 and one 500051-B21. | 500051-L21 | |
| | ||
| Memory | NOTE: DIMM banks are active only when the corresponding processor socket is populated. | |
| 2 GB REG PC2-6400 2 x 1 GB Kit |
497763-B21
|
|
| 2 GB REG PC2-5300 2 x 1 GB Low Power Single Rank Kit | 483399-B21 | |
| 4 GB REG PC2-6400 2 x 2 GB Kit |
497765-B21
|
|
| 4 GB REG PC2-5300 2 x 2 GB Low Power Single Rank Kit |
483401-B21
|
|
| 8 GB REG PC2-6400 2 x 4 GB Kit | 497767-B21 | |
| 8 GB REG PC2-6400 2 x 4 GB Low Power Kit | 504351-B21 | |
| 8 GB REG PC2-5300 2 x 4 GB Low Power Dual Rank Kit | 483403-B21 | |
| 16 GB REG PC2-5300 2 x 8 GB Kit | 408855-B21 | |
|
|
||
| Hard Drive | NOTE: The components
of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and
the server backplane) should operate at the same data transfer rate or the
system bandwidth will be negotiated down to an acceptable level for all
components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. |
|
| Serial-ATA (SATA) Non-Hot Plug Hard Drives (Non-Hot Plug Models Only) | ||
| SATA Non-Hot Plug 3.5" Entry (ETY) Drives | ||
| HP 160GB 3G SATA 7.2K NHP 3.5" ETY HDD |
458947-B21
|
|
| SATA Non-Hot Plug 3.5" Midline (MDL) Drives | ||
| HP 750GB 3G SATA 7.2K NHP 3.5" MDL HDD | 462595-B21 | |
| HP 500GB 3G SATA 7.2K NHP 3.5" MDL HDD | 458941-B21 | |
| HP 250GB 3G SATA 7.2K NHP 3.5" MDL HDD |
458939-B21
|
|
| SATA Hot Plug 3.5" Midline (MDL) Solid State Drives | ||
| HP 60GB 3G SATA 3.5in MDL 1y Wty SSD | 570761-B21 | |
| HP 120GB 3G SATA 3.5in MDL 1y Wty SSD | 570763-B21 | |
| 3.5" SATA Non-Hot Plug Drives | ||
| HP 500GB 1.5G SATA 7.2K NHP 3.5" HDD, FIO | 404469-B21 | |
| HP 250GB 1.5G SATA 7.2K NHP 3.5" HDD | 411276-B21 | |
| HP 160GB 1.5G SATA 7.2K NHP 3.5" HDD | 411275-B21 | |
| NOTE: The previous generation of 1.5G SATA drives are still supported. | ||
|
|
||
| Storage Controllers | NOTE: Storage Controller only required if 445148-B21 is selected in Step 1 above. | |
| HP Smart Array E500/256MB Controller
with Battery, FIO NOTE: Customers can only order one Smart Array E500/256MB Controller and one Battery-backed write cache upgrade (P/N 383280-B21) for the HP ProLiant DL165 G5p server based on battery space. |
462105-B21 | |
| HP Smart Array E200/128 BBWC Controller | 411508-B21 | |
| HP SC44Ge Host Bus Adapter NOTE: When using the SC44Ge with SATA Hard Drives, 1.5G SATA Hard Drives are required. |
416096-B21
|
|
| HP SC40Ge SAS HBA, FIO NOTE: When using the SC40Ge with SATA Hard Drives, 1.5G SATA Hard Drives are required. |
449176-B21
|
|
| HP SA-P400 and SA-E500 24 In Battery
Cable Kit NOTE: This option kit contains a 24" battery cable and adhesive material for installing a battery into the following servers if a Smart Array E500 is integrated outside of the factory. For all solutions, please refer to the HP ProLiant QuickSpecs and User's Manual for detailed installation instruction. |
417836-B21 | |
| Battery-backed write cache NOTE: When installing a battery-backed write cache module, the HP Smart Array E500 must be installed in the full-length PCI slot. 256MB Battery-backed write cache upgrade for RAID 5 support. |
383280-B21 | |
|
|
||
| Step 3: Choose Additional Factory Integratable Options | ||
| Backplane Option | Hot Plug HDD Backplane 1U 2S Kit NOTE: Installation of the Hot Plug Backplane 1U 2S Kit (445985-B21) is required if ordering third or fourth Hard Drives for Hot Plug models only in Step 1 above. |
445985-B21 |
| Power Supplies | HP 1200W High Efficiency Power
Supply Kit, FIO NOTE: Selection of the HE Power Supply Unit will remove the 650 Watt standard power supply and requires the purchase of Power Supply Backplane (P/N 453652-B21). |
453650-B21 |
| Power Options | ||
| Power Supply Backplane, FIO NOTE: This backplane must be ordered with the high efficiency power supply (P/N 453650-B21). |
453652-B21 | |
|
|
||
| Step 4: Choose Additional Options for Factory Integration |
| NOTE: For additional "Core Options" and "Additional Options", please refer to the options sections below. |
|
|
Core Options
| NOTE: Some options may not be available for factory integration. Please contact an HP sales representative for additional information. | ||
| Processor | AMD Opteron™ processor Model 2393SE (3.1GHz, 105W ACP) | 500062-B21 |
| AMD Opteron™ processor Model 2389 (2.9GHz, 75W ACP) | 500049-B21 | |
| AMD Opteron™ processor Model 2384 (2.7GHz, 75W ACP) | 500064-B21 | |
| AMD Opteron™ processor Model 2381HE (2.5GHz, 55W ACP) | 500058-B21 | |
| AMD Opteron™ processor Model 2380 (2.5GHz, 75W ACP) |
500060-B21
|
|
| AMD Opteron™ processor Model 2377EE (2.3GHz, 50W ACP) | 536530-B21 | |
| AMD Opteron™ processor Model 2376 HE (2.3GHz, 55W ACP) | 504540-B21 | |
| AMD Opteron™ processor Model 2376 (2.3GHz, 75W ACP) | 500056-B21 | |
| AMD Opteron™ processor Model 2374 HE (2.2GHz, 55W ACP) |
500051-B21
|
|
|
|
||
|
Memory (DIMMs) |
NOTE: DIMM banks are active only when the corresponding processor socket is populated. | |
| 2 GB REG PC2-6400 2 x 1 GB Kit | 497763-B21 | |
| 2 GB REG PC2-5300 2 x 1 GB Low Power Single Rank Kit | 483399-B21 | |
| 4 GB REG PC2-6400 2 x 2 GB Kit | 497765-B21 | |
| 4 GB REG PC2-5300 2 x 2 GB Low Power Single Rank Kit | 483401-B21 | |
| 8 GB REG PC2-6400 2 x 4 GB Kit | 497767-B21 | |
| 8 GB REG PC2-6400 2 x 4 GB Low Power Kit | 504351-B21 | |
| 8 GB REG PC2-5300 2 x 4 GB Low Power Dual Rank Kit | 483403-B21 | |
| 16 GB REG PC2-5300 2 x 8 GB Kit | 408855-B21 | |
|
|
||
| Optical Drives | DVD-ROM Drive Optical Drive |
447889-B21
|
| DVD/CD RW Drive Optical Drive |
447891-B21
|
|
|
|
||
| Hard Drives | NOTE: The components
of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and
the server backplane) should operate at the same data transfer rate or the
system bandwidth will be negotiated down to an acceptable level for all
components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. |
|
| Serial-ATA (SATA) Non-Hot Plug Hard Drives (Non-Hot Plug Models Only) | ||
| SATA Non-Hot Plug 3.5" Midline (MDL) Drives | ||
| HP 750GB 3G SATA 7.2K NHP 3.5" MDL HDD | 462595-B21 | |
| HP 500GB 3G SATA 7.2K NHP 3.5" MDL HDD | 458941-B21 | |
| HP 250GB 3G SATA 7.2K NHP 3.5" MDL HDD | 458939-B21 | |
| SATA Non-Hot Plug 3.5" Entry (ETY) Drives | ||
| HP 160GB 3G SATA 7.2K NHP 3.5" ETY HDD | 458947-B21 | |
| Serial-ATA (SATA) Hot Plug Hard Drives (SATA/SAS Hot Plug Models Only) | ||
| SATA Hot Plug 3.5" Entry (ETY) Drives | ||
| HP 160GB 3G SATA 7.2K 3.5" ETY HDD | 458945-B21 | |
| SATA Hot Plug 3.5" Midline (MDL) Drives | ||
| HP 1TB 3G SATA 7.2K 3.5" MDL HDD | 454146-B21 | |
| HP 750GB 3G SATA 7.2K 3.5" MDL HDD | 458930-B21 | |
| HP 500GB 3G SATA 7.2K 3.5" MDL HDD | 458928-B21 | |
| HP 250GB 3G SATA 7.2K 3.5" MDL HDD | 458926-B21 | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_na/13021_na.html | ||
| 3.5" SATA Hot Plug Drives | ||
| HP 750GB 1.5G SATA 7.2K 3.5" HDD | 432341-B21 | |
| HP 500GB 1.5G SATA 7.2K 3.5" HDD | 395473-B21 | |
| HP 250GB 1.5G SATA 7.2K 3.5" HDD | 349239-B21 | |
| HP 160GB 1.5G SATA 7.2K 3.5" HDD | 349238-B21 | |
| 3.5" SATA Non-Hot Plug Drives | ||
| HP 250GB 1.5G SATA 7.2K NHP 3.5" HDD | 411276-B21 | |
| HP 160GB 1.5G SATA 7.2K NHP 3.5" HDD | 411275-B21 | |
| NOTE: The previous
generation of 1.5G SATA drives are still supported. NOTE: Please see the QuickSpecs for Technical Specification and additional information: http://h18000.www1.hp.com/products/quickspecs/11940_na/11940_na.html |
||
| SATA Hot Plug 3.5" Midline (MDL) Solid State Drives | ||
| HP 60GB 3G SATA 3.5in MDL 1y Wty SSD | 570761-B21 | |
| HP 120GB 3G SATA 3.5in MDL 1y Wty SSD | 570763-B21 | |
| NOTE: Please see
QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13415_na/13415_na.html |
||
| SAS Hot Plug 3.5" Enterprise (ENT) Drives | ||
| HP 600GB 6G SAS 15K 3.5" DP ENT HDD | 516828-B21 | |
| HP 450GB 6G SAS 15K 3.5" DP ENT HDD | 516816-B21 | |
| HP 450GB 3G SAS 15K 3.5" DP ENT HDD | 454232-B21 | |
| HP 300GB 6G SAS 15K 3.5" DP ENT HDD | 516814-B21 | |
| HP 300GB 3G SAS 15K 3.5" DP ENT HDD | 416127-B21 | |
| HP 146GB 3G SAS 15K 3.5" DP ENT HDD | 384854-B21 | |
| SAS Hot Plug 3.5" Midline (MDL) Drives | ||
| HP 1TB 3G SAS 7.2K 3.5" DP MDL HDD | 461137-B21 | |
| HP 750GB 3G SAS 7.2K 3.5" DP MDL HDD | 461135-B21 | |
| NOTE: The purchase of SAS HBA or array controller is required. | ||
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12244_na/12244_na.html | ||
|
|
||
| Communications | Gigabit Ethernet Adapters | |
| HP NC112T PCIe Gigabit Server Adapter | 503746-B21 | |
| HP NC360T PCI Express Dual Port Gigabit Server Adapter | 412648-B21 | |
| HP NC364T PCI Express Quad Port Gigabit Server Adapter | 435508-B21 | |
| HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter | 458492-B21 | |
| 10 Gigabit Ethernet Adapters | ||
| HP NC522SFP Dual Port 10GbE Server
Adapter NOTE: A minimum of two Gigabytes (2 GB) of server memory is required per each NC522SFP adapter. NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately. |
468332-B21 | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs |
|
|
Additional Options
|
Remote Management |
HP Lights-Out 100i Advanced Pack | |
| HP LO100i Advanced Pack, No Media 1-Server License including 1 year of 24x7 Technical Support and Updates |
530521-B21
|
|
| NOTE: Flexible and volume quantity (AKA) license kits are available for the Lights-Out 100i Advanced Pack licenses as well as Electronic License To Use (E-LTU). AKA Tracking licenses require a 100 unit minimum forecast at initial contract signing. For these additional part numbers, please refer to QuickSpecs at this link for more information: www.hp.com/go/lo100 | ||
|
|
||
|
HP Insight Software |
HP Insight Control for Linux | |
| HP Insight Control for Linux, 1-server license, including one year of 24x7 Technical Support and Updates, Electronic |
T9084BAE
|
|
| HP Insight Control for Linux, No Media, 1-Server license, including one year of 24x7 Technical Support and Updates | 464423-B22 | |
| HP Insight Control for Linux,
Media pack (DVD) - No licenses included NOTE: Media pack DVD contains HP Insight Control for Linux, HP Systems Insight Manager, HP Insight Control power management, HP Insight Control virtual machine management, and an integrated installer. Licenses must be acquired separately NOTE: This Media pack is optional because the latest ISO image and latest updates may be downloaded at no cost from: http://www.hp.com/go/ic-linux (click on Download button). |
464422-B22 | |
| NOTE: Electronic
licenses can be used to purchase multiple licenses with a single activation
key, and are available in all countries except China and Japan. Customers
in China and Japan should order the physical equivalent. NOTE: Customer will receive a license entitlement certificate, which must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. NOTE: For additional License Kits, including electronic licensing options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_na/13019_na.html |
||
| HP Insight Control server deployment | ||
| HP Insight Control server deployment Electronic License including 1 year 24x7 Technical Support and Updates | T9082AAE | |
| HP Insight Control server deployment 1-Server License including 1 year 24x7 Technical Support and Updates | 452151-B21 | |
| NOTE: Licenses
ship without media. The Insight Control Media Kit can be ordered separately,
or can be downloaded at: http://www.hp.com/go/insightupdates.
NOTE: Electronic licenses can be used to purchase multiple licenses with a single activation key, and is available in all countries except China and Japan. Customers in China and Japan should order the physical equivalent. NOTE: Customer will receive a license entitlement certificate, which must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. NOTE: For additional license kits please see the Insight Control QuickSpecs at: http://h18004.www1.hp.com/products/quickspecs/12631_na/12631_na.html |
||
|
|
||
| Hot Plug HDD Backplane Option | Hot Plug HDD Backplane 1U 2S Kit
NOTE: Installation of the Hot Plug Backplane 1U 2S Kit (445985-B21) is required if ordering third or fourth Hard Drives for Hot Plug models only. |
445985-B21
|
|
| ||
| Storage Controllers | NOTE: The addition of storage controllers for internal hard drive use is intended for use ONLY with the Hot Plug SATA/SAS Model Chassis (495841-B21). | |
| SAS Controllers | ||
| Smart Array E200 Controller | ||
| HP Smart Array E200/128 BBWC Controller | 411508-B21 | |
| Smart Array P400 Controller | ||
| HP Smart Array P400/256MB Controller NOTE: Customers can only order one Smart Array P400/256MB Controller and one Battery-backed write cache upgrade (P/N 383280-B21) for the HP ProLiant DL165 G5 server based on battery space. |
405132-B21 | |
| HP Smart Array P400/512MB BBWC
Controller NOTE: Customers can only order one Smart Array P400/512MB BBWC Controllers for the HP ProLiant DL165 G5p server based on battery space. |
411064-B21 | |
| Smart Array P800 Controller | ||
| HP Smart Array P800/512 BBWC Controller | 381513-B21 | |
| NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12460_na/12460_na.html
(Smart Array E200 Controller) http://h18000.www1.hp.com/products/quickspecs/12400_na/12400_na.html (Smart Array P400 Controller) http://h18000.www1.hp.com/products/quickspecs/12616_na/12616_na.html (Smart Array P800 Controller) |
||
| Optional Upgrades | ||
| 512MB Battery-backed write cache
upgrade NOTE: Contains battery and memory module. For Smart Array P400 Controller. |
405148-B21 | |
| HP SA-P400 and SA-E500 24 In Battery
Cable Kit NOTE: This option kit contains a 24" battery cable and adhesive material for installing a battery into the following servers if a Smart Array E500 is integrated outside of the factory. For all solutions, please refer to the HP ProLiant QuickSpecs and User's Manual for detailed installation instruction. |
417836-B21 | |
| SAS HBA | ||
| HP SC44Ge Host Bus Adapter NOTE: When using the SC44Ge with SATA Hard Drives, 1.5G SATA Hard Drives are required. NOTE: PCI-Express SAS HBA. |
416096-B21 | |
| NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information: http://h18004.www1.hp.com/products/quickspecs/12617_na/12617_na.html (SC44Ge HBA) |
||
| SCSI HBA | ||
| HP SC11Xe Host Bus Adapter NOTE: Recommended HBA for SCSI tape drive connect. |
412911-B21
|
|
| NOTE: Please see
the following QuickSpecs for Technical Specifications additional information: http://h18000.www1.hp.com/products/quickspecs/12566_na/12566_na.html (SC11Xe HBA) |
||
|
|
||
| HPC Specific Options | HP IB 4X DDR PCI-e Dual Port HCA | 448397-B21 |
| HP10GbE PCI-e G2 Dual Port Network Adapter | 516937-B21 | |
| HP 10 GbE PCI-e G2 Dual Port Adapter | 516937-B21 | |
| NOTE: For HPC interconnect adapters please see the HPC Interconnect section of this QuickSpecs. | ||
|
|
||
| Tape Storage | NOTE: For the
complete listing of Tape Drive offerings, please see: http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html |
|
| Tape Drives | ||
| USB Rack-Mount Tape Solutions | ||
| HP StorageWorks 1U USB Rack-Mount
Kit with one DAT 160 USB Tape Drive NOTE: Pre-configured with one DAT 160 USB tape drive. |
AG703A
|
|
| SAS Rack-Mount Tape Solutions NOTE: HP recommends purchasing the HP SC44Ge HBA (416096-B21) for a dedicated SAS HBA for tape. |
||
| HP StorageWorks 1U SAS Rack-Mount
Kit with one LTO-4 Ultrium 1760 NOTE: Pre-configured with one LTO-4 Ultrium 1760 SAS tape drive. |
EH946A | |
| HP StorageWorks 1U SAS Rack-Mount
Kit NOTE: Supports up to (2) half-height SAS tape drives. |
AE459A | |
|
HP StorageWorks DAT 160 SAS Internal Tape Drive |
Q1587A
|
|
|
HP StorageWorks LTO-2 Ultrium 448 SAS Internal Tape Drive |
DW085A
|
|
|
HP StorageWorks LTO-3 Ultrium 920 SAS Internal Tape
Drive |
EH847A
|
|
| SCSI Rack-Mount Tape Solutions NOTE: SCSI Controller required. HP recommends purchasing the HP SC11Xe HBA (412911-B21) for a dedicated SCSI HBA for tape. |
||
| HP StorageWorks 1U SCSI Rack-mount
kit with one LTO-2 Ultrium 448 SCSI Tape Drive (Carbonite) NOTE: Pre-configured with one LTO-2 Ultrium 448 SCSI tape drive. |
DW028B
|
|
| HP StorageWorks 1U SCSI Rack-mount
kit with one LTO-3 Ultrium 920 NOTE: Pre-configured with one LTO-3 Ultrium 920 SCSI tape drive. |
EH903A
|
|
| HP StorageWorks 3U SCSI Rack-Mount
with 1 LTO-4 Ultrium 1840 Tape Drive NOTE: Pre-configured with one LTO-4 Ultrium 1840 SCSI tape drive. |
EH926A | |
| NOTE: For an up-to-date listing of the latest O/S and software support details for HP Ultrium tape drives, please visit: http://www.hp.com/go/connect | ||
| Tape Autoloaders | ||
| HP StorageWorks DAT Autoloader | ||
| HP StorageWorks DAT 72x10 tape autoloader | AE313B | |
| HP StorageWorks 1/8 G2 Tape Autoloader | ||
| HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader | AK377A | |
| HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Autoloader | AH558A | |
| HP StorageWorks 1/8 G2 LTO-2 Ultrium 448 Tape Autoloader | AH164A | |
| HP StorageWorks 1/8 G2 Tape Autoloader
Rack Kit NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions. |
AH166A | |
| NOTE: Please reference the QuickSpecs for Technical Specifications and http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs. | ||
| Tape Libraries | ||
| HP StorageWorks MSL2024 Tape Library | ||
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1840 SCSI Drive Library | AJ033A | |
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SAS Drive Library | AK378A | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 960 SCSI Drive Library | AG115A | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SAS Drive Library | AH559A | |
| HP StorageWorks MSL2024 1 LTO-2 Ultrium 448 SCSI Drive Library | AG116A | |
| HP StorageWorks MSL4048 Tape Library | ||
| HP StorageWorks MSL4048 1 LTO-4 Ultrium 1840 SCSI Drive Library | AJ035A | |
| HP StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SAS Drive Library | AK380A | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 960 SCSI Drive Library | AG322A | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SAS Drive Library | AH560A | |
|
|
||
| Disk-Based Backup | RDX Removable Disk Backup | |
| HP StorageWorks RDX160 External
Removable Disk Backup System NOTE: 160GB of Disk Storage |
AJ766A | |
| HP StorageWorks RDX320 External
Removable Disk Backup System NOTE: 320GB of Disk Storage |
AJ768A | |
| HP StorageWorks RDX500 External
Removable Disk Backup System NOTE: 500GB of Disk Storage |
AJ935A | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13036_na/13036_na.html |
||
| D2D Backup | ||
| HP StorageWorks D2D2504i Backup
System NOTE: 4 TB raw capacity/3 TB useable capacity. |
EJ002A | |
|
HP StorageWorks D2D130 Backup System with LTO-3 Ultrium 920 SAS Tape
Drive |
EH952A
|
|
| HP StorageWorks D2D2503i Backup
System NOTE: 3TB of Disk Storage |
EH945A | |
| HP StorageWorks D2D4004i Backup
System NOTE: 4.5TB of Disk Storage |
EH938A | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://www.hp.com/go/d2d. | ||
|
|
||
| StorageWorks Options | StorageWorks Fibre Channel HBA NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows and Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html |
|
| Brocade Fibre Channel HBAs | ||
| HP 81B PCIe 8Gb FC Single Port HBA |
AP769A
|
|
| HP 82B PCIe 8Gb FC Dual Port HBA |
AP770A
|
|
| HP 41B PCIe 4Gb FC Single Port HBA |
AP767A
|
|
| HP 42B PCIe 4Gb FC Dual Port HBA |
AP768A
|
|
| Emulex Fibre Channel HBAs | ||
| HP StorageWorks 81E 8Gb Single Port PCI-e FC HBA | AJ762A | |
| HP StorageWorks 82E 8Gb Dual Port PCI-e FC HBA |
AJ763A
|
|
| HP StorageWorks FC2142SR 4Gb PCI-e FC HBA | A8002A | |
| HP StorageWorks FC2242SR Dual Channel 4Gb PCI-e FC HBA | A8003A | |
| QLogic Fibre Channel HBAs | ||
| HP StorageWorks 81Q 8Gb Single Port PCI-e FC HBA | AK344A | |
| HP StorageWorks 82Q 8Gb Dual Port PCI-e FC HBA | AJ764A | |
| HP StorageWorks FC1142SR 4Gb PCI-e FC HBA | AE311A | |
| HP StorageWorks FC1242SR Dual Channel 4Gb PCI-e FC HBA | AE312A | |
| StorageWorks SCSI HBA | ||
| HP U320e SCSI Host Bus Adapter NOTE: Recommended HBA for MSL SCSI Tape Library connect. |
AH627A
|
|
|
|
||
| HP StorageWorks Modular Smart Array |
HP StorageWorks 50 Modular Smart Array |
|
| HP StorageWorks 50 Modular Smart
Array NOTE: Rack-mountable 10 SFF drive enclosure with single I/O module, redundant hot plug power supplies and hot plug fans. |
364430-B21 | |
| HP StorageWorks 60 Modular Smart Array | ||
| HP StorageWorks 60 Modular Smart Array | 418408-B21 | |
| NOTE: Rack-mountable
12-drive (3.5" 3G SAS/1.5G SATA) 2U enclosure with 3Gb/s SAS host connectivity
and redundant power supplies. NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12627_na/12627_na.html |
||
| HP StorageWorks 70 Modular Smart Array | ||
| HP StorageWorks 70 Modular Smart Array | 418800-B21 | |
| NOTE: Rack-mountable
25-drive (2.5" 3G SAS/1.5G SATA) 2U enclosure with 3Gb/s SAS host connectivity
and redundant power supplies. NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12652_na/12652_na.html |
||
|
|
||
| Uninterruptible Power Systems | HP Rack-mountable UPS | |
| HP R1500 G2 UPS | ||
| HP, R1.5kVA UPS, 1U |
AF419A
|
|
| NOTE: Please see
QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12507_na/12507_na.html NOTE: For additional information on sizing your server, please reference: http://www.upssizer.com |
||
| HP R3000 UPS Uninterruptible Power System | ||
| HP R3000 UPS |
AF444A
|
|
| NOTE: Please see
UPS QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13129_na/13129_na.html |
||
|
|
||
| HP Monitored Power Distribution Units | Monitored PDUs | |
| HP Monitored Power Distribution Unit: Full Rack Version | ||
| HP 17.3 kVA S2324 Monitored PDU- dual input, 3Ř, 24A |
AF503A
|
|
| HP 8.6 kVA S1324 Monitored PDU- single input, 3Ř, 24A |
AF504A
|
|
| HP 16.6 kVA S2140 Monitored PDU- dual input, 1Ř, 40A |
AF505A
|
|
| HP 8.3 S1140 Monitored PDU- single input, 1Ř, 40A |
AF506A
|
|
| HP Monitored Power Distribution Unit: Half Rack Version | ||
| HP 17.3 kVA S348 Monitored PDU- single input, 3Ř, 48A | AF916A | |
| HP 4.9 kVA S124 Monitored PDU- single input, 1Ř, 24A | AF914A | |
| Modular Power Distribution Units 1U/0U (Up to 32 outlets) | ||
| NOTE: 1U/0U mounting brackets shipped with the unit (optimized for 10000 G2 and 9000 series racks). | ||
| HP Modular Power Distribution
Units (mPDU), Low Volt Model, 24A (100-127 VAC) NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of the UPS R3000 XR. |
252663-D71 | |
| HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC) | 252663-D72 | |
| HP Modular Power Distribution
Units (mPDU), High Volt Model, 40A (200-240 VAC) NOTE: This mPDU (252663-B21), 40A model has a hardwired input. |
252663-B21 | |
| HP Modular Power Distribution
Units (mPDU), High Volt Model, 16A (200-240 VAC) NOTE: This PDU has a detachable input power cord and allows for adaptability to country specific power requirements. |
252663-B24 | |
| NOTE: Please see
the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables and country specific
power cords: http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html NOTE: For additional information on HP Power Distribution Units including accessories please go to: www.hp.com/go/pdu. |
||
|
|
||
| HP Rack Options | HP KVM Switch Options | |
| HP 1x4 Console Switch |
AF611A
|
|
| HP PS2 Server Console Cable, 6 foot, 2-Pack |
AF612A
|
|
| HP USB Server Console Cable, 6
foot, 2-Pack NOTE: required for supporting USB peripheral. |
AF613A
|
|
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| USB Options | HP USB Internal Cable Kit |
451363-B21
|
| 1.44MB External USB Floppy Drive All |
DC141B
|
|
| USB Floppy Drive | DC361B | |
| USB P/S2 Optical Mouse | DC369A | |
| USB Standard Keyboard | DT528A#ABA | |
|
|
||
| Service and Support
Offerings (HP Care Pack Services) |
Hardware Services 4-Hour On-site Service | |
| 13-Hour x 5-Day Coverage, 3 Years, Electronic |
U9509E
|
|
| 24-Hour x 7-Day Coverage, 3 Years, Electronic |
U9510E
|
|
| Hardware Services Next Business Day On-Site Service | ||
| 9-Hour x 5-Day Coverage, 3 Years, Electronic |
U9508E
|
|
| Hardware Services 6-Hour Call to Repair On-Site Service | ||
| 9-Hour x 5-Day Coverage, 3 Years, Electronic | U9511E | |
| Hardware Installation, Electronic |
U9520E
|
|
| NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack |
|
|
Memory
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
| HP ProLiant DL165 G5p (all models) |
| Standard Memory 2 GB (2 x 1 GB) PC2-6400 DIMM memory, with Advanced ECC Capabilities memory installed. Maximum Memory Up to 128GB memory is available with the optional installation of PC2-5300 Registered DIMM memory kits. Memory should be installed in pairs and matched for optimum performance. |
| NOTE:
Chart does not represent all possible memory configurations. NOTE: DIMM banks are active only when the corresponding processor socket is populated. |
| Memory |
Slot
|
|||||||
|
1
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
|
| Standard (2 GB) |
1 GB
|
1 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
| Maximum (128 GB) |
4 GB
|
4 GB
|
4 GB
|
4 GB
|
4 GB
|
4 GB
|
4 GB
|
4 GB
|
| 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | |
| 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | |
|
Following are memory options available from HP: |
|
|
2 GB REG PC2-6400 2 x 1 GB Kit |
497763-B21
|
| 2 GB REG PC2-5300 2 x 1 GB Low Power Single Rank Kit |
483399-B21
|
|
4 GB REG PC2-6400 2 x 2 GB Kit |
497765-B21
|
| 4 GB REG PC2-5300 2 x 2 GB Low Power Single Rank Kit |
483401-B21
|
| 8 GB REG PC2-6400 2 x 4 GB Kit | 497767-B21 |
| 8 GB REG PC2-6400 2 x 4 GB Low Power Kit | 504351-B21 |
| 8 GB REG PC2-5300 2 x 4 GB Low Power Dual Rank Kit | 483403-B21 |
| 16 GB REG PC2-5300 2 x 8 GB Kit | 408855-B21 |
|
|
Storage
|
|
1-4 | Non-hot plug 3.5" SATA or Hot-plug SAS/SATA hard drive bays |
| A | Optional DVD-ROM, or DVD/CD RW |
|
Drive Support |
|||
|
|
|||
| Removable Media | |||
|
Quantity |
Position |
Controller |
|
|
DVD-ROM |
Up to 1 |
A |
Integrated IDE (ATAPI) (optional) |
| DVD/CD RW |
Up to 1 |
A |
Integrated IDE (ATAPI) (optional) |
|
|
|||
|
Hard Drives |
|||
| SATA Non-Hot Plug 3.5" Entry (ETY) Drives | |||
|
Quantity |
Position |
Controller |
|
| 160GB 3G SATA 7.2K |
Up to 4
|
1-4
|
HP Embedded SATA Controller |
|
|
|||
| SATA Non-Hot Plug 3.5" Midline (MDL) Drives | |||
|
Quantity |
Position |
Controller |
|
| 750GB 3G SATA 7.2K 500GB 3G SATA 7.2K 250GB 3G SATA 7.2K |
Up to 4
|
1-4
|
HP Embedded SATA Controller |
|
|
|||
| 3.5" SATA Non-Hot Plug Drives | |||
|
Quantity |
Position |
Controller |
|
| 500GB 1.5G SATA,FIO 250GB 1.5G SATA 7.2K 160GB 1.5G SATA 7.2K |
Up to 4
|
1-4
|
HP Embedded SATA Controller |
|
|
|||
| SATA Hot Plug 3.5"
Entry (ETY) Drives NOTE: Installation of the Hot Plug Backplane 1U 2S Kit (445985-B21) is required if ordering third or fourth Hard Drives for Hot Plug models only. |
|||
|
Quantity |
Position |
Controller |
|
| 160GB 3G SATA 7.2K |
Up to 4
|
1-4
|
HP Embedded SATA Controller |
|
|
|||
| SATA Hot Plug 3.5" Midline (MDL) Drives | |||
|
Quantity |
Position |
Controller |
|
| 1TB 3G SATA 7.2K 750GB 3G SATA 7.2K 500GB 3G SATA 7.2K 250GB 3G SATA 7.2K |
Up to 4
|
1-4
|
HP Embedded SATA Controller |
|
|
|||
| SATA Hot Plug 3.5" Midline (MDL) Solid State Drives | |||
|
Quantity |
Position |
Controller |
|
| 120GB 3G SATA 60GB 3G SATA |
Up to 4
|
1-4
|
HP SC40Ge 4-Port Internal SAS
HBA with RAID 0, 1 NOTE: When using the SC40Ge with SATA Hard Drives, 1.5G SATA Hard Drives are required. Transfer rate: 1.5 Gb/s SATA, 3 Gb/s SAS HP Smart Array P400 Controller HP Smart Array P800 Controller |
|
|
|||
| SAS Hot Plug 3.5" Enterprise (ENT) Drives | |||
|
Quantity |
Position |
Controller |
|
| 600GB 6G SAS 15K 450GB 6G SAS 15K 450GB 3G SAS 15K 300GB 3G SAS 15K 146GB 3G SAS 15K |
Up to 4
|
1-4
|
HP 4 Internal Port SAS HBA with RAID |
|
|
|||
| Tape and Disk-Based Backup |
|
NOTE: For a complete listing of compatible tape and disk-based
backup offerings, please visit: http://www.hp.com/go/connect |
| Position Supported |
Controller |
Controller Part Number | |
|
HP StorageWorks SCSI Tape Drives, External |
External |
HP SC11Xe Host Bus Adapter | 412911-B21 |
|
HP StorageWorks USB Tape Drives, External |
External |
USB 2.0 Port | N/A |
|
HP StorageWorks SAS Tape Drives, External |
External |
HP SC44Ge Host Bus Adapter | 416096-B21 |
|
HP StorageWorks SCSI Tape Automation, External |
External |
HP SC11Xe Host Bus Adapter |
412911-B21 AH627A |
|
HP StorageWorks SAS Tape Automation, External |
External |
HP SC44Ge Host Bus Adapter |
416096-B21 |
|
HP StorageWorks Fibre Tape Automation, External | External |
Please consult the EBS connectivity matrix at: http://www.hp.com/go/ebs
for detailed connectivity information. |
N/A |
| HP StorageWorks
RDX Removable Disk Backup System, External RDX160 RDX320 RDX500 | External | USB 2.0 port | N/A |
|
HP StorageWorks D2D Backup Systems | External |
Embedded Network Controller |
N/A |
|
|
Power Specifications
| Operational Input Voltage Range (Vrms) | 90Vac to 264Vac full range at 25oC ambient | |||||
| Frequency Range (Nominal) (Hz) | 47 Hz to 63 Hz | |||||
| Power Output | 650W Nominal | |||||
| Server Power Cords |
One 6' Highline (IEC-IEC) power cord ships standard |
|||||
|
|
Technical Specifications
| System Unit | Dimensions (H x W x D) (with bezel) |
1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68.20 cm) | |
| Weight (approximate) |
Maximum (all hard drives, power supplies, and processors installed) |
37.00 lb (16.78 kg) | |
| Minimum (one hard drive, power supply, and processor installed) |
30.00 lb (13.69 kg) | ||
| Input Requirements (per 650W power supply) |
Rated Line Voltage |
100-127 VAC, |
|
| Rated Input Current |
10.0 A (at 115 VAC), |
||
| Rated Input Frequency | 47 to 63 Hz | ||
| Rated Input Power |
852.16 W (at 100 VAC), |
||
| BTU Rating | Maximum |
2217.89 BTU/hr (at 100 VAC), |
|
| Power Specifications |
To review typical system power ratings use the Power Advisor which is
available via the online tool located at URL:
www.hp.com/go/proliant-energy-efficient |
||
| Power Supply Output (per power supply) |
Rated Steady-State Power |
650 W (at 100 VAC), |
|
| Maximum Peak Power |
700 W (at 100 VAC), |
||
| Optional High Efficiency Power Supply Specifications | |||
|
Input Requirements |
Rated Line Voltage |
90-132 VAC, |
|
| Rated Input Current |
9.4 A (at 115 VAC), |
||
| Rated Input Frequency | 47 to 63 Hz | ||
| Rated Input Power |
1075 W (at 100 VAC), |
||
| BTU Rating | Maximum |
3070.93 BTU/hr (at 100 VAC), |
|
|
Power Specifications |
To review typical system power ratings use the Power Advisor which is
available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient |
||
| Power Supply Output (per power supply) |
Rated Steady-State Power |
900 W (at 100 VAC), |
|
| Maximum Peak Power |
900 W (at 100 VAC), |
||
| System Inlet Temperature | Operating |
10° to 35°C (50° to 95°F) at sea level with an altitude
derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above
sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight.
Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may
be limited by the type and number of options installed. |
|
| Non-operating | -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). | ||
| Relative Humidity (non-condensing) |
Operating | 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. | |
| Non-operating | 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. | ||
| Altitude | Operating | 3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | |
| Non-operating | 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | ||
| Acoustic Noise | Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). | ||
| Idle | |||
| LWAd | 6.82 B | ||
| LpAm | 51.93 dBA | ||
| Operating | |||
| LWAd | 6.84 B | ||
| LpAm | 51.93 dBA | ||
| Emissions Classification (EMC) | FCC Rating | Class A | |
| Normative Standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 | ||
| NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements. | |||
|
|
|||
| HP 160GB 1.5G SATA
7.2K NHP 3.5" ETY HDD 458947-B21 |
160-GB 7.2K | Capacity | 160,041 MB | |
| Height | 1.028 in (2.61 cm) | |||
| Width | 4.0 in (10.16 cm) | |||
| Depth | 5.787 in (147.0 mm) | |||
| Interface | Serial ATA | |||
| Transfer Rate Synchronous (Maximum) |
1.5Gb/s | |||
| Native Command Queuing | N/A | |||
| Seek Time (typical reads, including settling) |
Single Track | 2.0 ms | ||
| Average | <11 ms | |||
| Full-Stroke | 23.0 ms | |||
| Rotational Speed | 7,200 rpm | |||
| Physical Configuration | Bytes/Sector | 512 | ||
| Logical Blocks | 312,581,808 | |||
| Operating Temperature | 41° to 131° F (5° to 55° C) | |||
|
|
||||
| Embedded SATA Controller | Drives Supported | Up to 4 SATA devices |
| Channels | 4 1.5Gb SATA | |
| Storage Capacity | 3.0TB internal storage | |
| Data Transfer Method | 32-bit/33-MHz PCI bus-master | |
| Maximum SATA Channel Transfer Rate | 1.5Gb/s per channel | |
| Maximum Transfer Rate per PCI Bus (peak) | 266 MB/s per channel | |
| Protocols | SATA | |
| PIO Mode[0-4] | ||
| Cable | SATA | |
| Internal ATA Connectors | Four SATA connectors | |
|
|
||
| HP 8 Internal Port SAS HBA with RAID | Drives Supported | Up to 4 SATA/SAS drives |
| Channels | 4 | |
| Storage Capacity | 1.8TB SAS, 3.0TB SATA | |
| Data Transfer Method | PCI-Express | |
| Maximum SAS Channel Transfer Rate | 3Gb/s per channel | |
| Maximum SAS transfer rate | 300Mb/sec per port | |
| Protocols Supported | SSP, STP, SMP | |
| Internal Connectors | 1 SAS | |
|
|
||
| Embedded NC362i Dual Port Gigabit Server Adapter | Network Interface |
10Base-T/ |
|
| Compatibility | IEEE 802.3 10Base-T | ||
| IEEE 802.3 1000Base-T | |||
| IEEE 802.3 100Base-TX | |||
| Data Transfer Method | PCI-X | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) |
2000 Mb/s | ||
| Connector | RJ-45 | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP; up to 328 ft (100 m) | |
| 10/100/1000Base-TX | Category 5 UTP (2 Pair); up to 328 ft (100 m) | ||
|
|
|||
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go
to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will
be recycled, recovered or disposed of in a responsible manner. |
|
|
||
| © Copyright 2009 Hewlett-Packard
Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. AMD, Opteron, and Hyper-Transport are trademarks of AMD Corporation in the United States and other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less. |