Overview
|
HP ProLiant DL380 Generation 6 (G6) | |||
|
| ![]() | ||
| Front View: | Rear View: | ||
| 1. | Quick removal access panel | 1. | PCI slot 5 |
| 2. | Intel Quad-Core Processor (Performance models include two processors) | 2. | PCI slot 6 |
| 3. | PCI slot 4 | ||
| 3. | Second Intel Quad-Core Processor | 4. | PCI slot 2 |
| 4. | Eighteen slots: DDR3 Registered (RDIMM) or Unbuffered (UDIMM) memory | 5. | PCI slot 3 |
| 6. | PCI slot 1 | ||
| 7. | Power supply 2 | ||
| 5. | Hot-plug fans, full N+1 redundancy | 8. | Power supply 1 |
| 6. | Slim Optical Bay (SATA DVD-RW Optical Drive included on Performance models) | 9. | USB connectors (2) |
| 10. | Video connector | ||
| 7. | UID LED button | 11. | NIC 1 connector |
| 8. | Health LED | 12. | NIC 2 connector |
| 9. | Power On/Standby button and system power LED | 13. | Mouse connector |
| 10. | USB connectors (2) | 14. | Keyboard connector |
| 11. | Video connector | 15. | Serial connector |
| 12. | Systems Insight Display | 16. | iLO2 connector |
| 17. | NIC 3 connector | ||
| 18. | NIC 4 connector | ||
| | |||
| What's New |
|
|
|
| At A Glance |
| The HP ProLiant DL380 G6 Server continues to deliver on its heritage of engineering excellence with increased flexibility and performance, enterprise-class uptime and manageability, 2-socket Intel Xeon performance, and 2U density for a variety of applications.
|
|
|
Standard Features
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | |
| Processor One of the following depending on Model |
Quad-Core Processors |
| Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | |
| Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | |
| Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | |
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor L5530 (2.40 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) | |
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800) | |
| Dual-Core Processors | |
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) | |
| NOTE: HT indicates
that the processor model supports Intel® Hyper-Threading Technology. NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active. NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. NOTE: Up to 2 processors supported. Performance configurations include two processors. Mixing different processor models is not supported. |
|
|
|
|
| Cache
Memory One of the following depending on Model | 8MB
(1 x 8MB) Level 3 cache NOTE: All processor models except for those identified below. |
| 4MB
(1 x 4MB) Level 3 cache NOTE: For processors E5506/L5506/E5504/E5502. | |
|
| |
| Chipset | Intel® 5520 Chipset NOTE: For more information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/. |
|
|
|
| Upgradeability | Upgradeable to 2 processors (8 cores) |
|
|
|
| Memory Protection | Advanced ECC (multi-bit error protection) |
| Mirroring mode | |
| Lockstep mode | |
| | |
| Memory | Type | DDR3 Registered (RDIMM) and Unbuffered (UDIMM) |
| Standard (Performance Models) | 12 GB (6 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Standard (Base Models) | 6 GB (3 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Standard (Entry Models) | 4 GB (2 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Standard (High Efficiency Models) | 4 GB (2 x 2 GB) PC3-10600E (DDR3-1333) Unbuffered DIMMs | |
| Maximum (RDIMM) | 192 GB (12 x 16 GB) for Registered Memory configurations | |
| Maximum (UDIMM) | 24 GB (12 x 2 GB) for Unbuffered Memory configurations | |
| NOTE:
If only one processor is installed, only half the DIMM slots are available NOTE: Depending on the memory configuration and processor model, the memory speed may run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration Tool at: www.hp.com/go/ddr3memory-configurator. | ||
DDR3
memory options part number decoder | ||
![]() | ||
| | ||
| Network Controller | Two HP NC382i Dual Port Multifunction Gigabit Server Adapters (four ports total) with TCP/IP Offload Engine, including support for Accelerated iSCSI |
|
|
|
| Expansion Slots
NOTE: The system board has 2 PCI connectors, but the below riser cards have the actual PCI slots, to which PCI cards attach. |
|||||||
| Primary
Riser (Standard) |
Expansion Slots # |
Technology |
Bus Width** |
Connector Width |
Bus Number* |
Form Factor |
Notes |
|
1 |
PCIe Gen2
|
X8 |
X16 |
7 |
Full Length, Full Height Slot
| ||
| 2 | PCIe Gen2 | X4 | X8 | 10 | Half Length, Full Height Slot | ||
| 3 |
PCIe Gen2
|
X4 |
X8 |
13 |
Half Length, Full Height Slot | ||
| *
Default bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. | |||||||
| PCIe
Riser (Optional Secondary) |
Expansion Slots # |
Technology |
Bus Width** |
Connector Width |
Bus Number* |
Form Factor |
Notes |
| 4 | PCIe Gen2 | X8 | X16 | 16 | Full length, full height slot | ||
| 5 | PCIe Gen2 | X4 | X8 | 20 | Half length, half height slot | ||
| 6 | PCIe Gen2 | X4 | X8 | 23 | Half length, half height slot | ||
| *
Default bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. | |||||||
| PCIe/PCI-X Riser (Optional Primary) |
Expansion Slots # |
Technology |
Bus Width** |
Connector Width |
Bus Number* |
Form Factor |
Notes |
| 1 | PCI-X (133MHz) | 64-bit | N/A | 7 | Full length, Full Height | ||
| 2 | PCI-E Gen2 | X8 | X16 | 11 | Half Length, Full Height | ||
| 3 | PCI-E Gen2 | X4 | X8 | 15 | Half Length, Full Height | ||
| *
Default bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. | |||||||
| PCIe/PCI-X Riser (Optional Secondary) |
Expansion Slots # |
Technology |
Bus Width** |
Connector Width |
Bus Number* |
Form Factor |
Notes |
| 4 | PCI-X (133MHz) | 64-bit | Not applicable | 19 | Full length, Full height slot | ||
| 5 | PCI-E Gen2 | X8 | X16 | 23 | Half Length, Half Height | ||
| 6 | PCI-E Gen2 | X4 | X8 | 27 | Half Length, Half Height | ||
| *
Default bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. | |||||||
| x16
PCIe Riser (Optional Primary) |
Expansion Slots # |
Technology |
Bus Width** |
Connector Width |
Bus Number* |
Form Factor |
Notes |
| 1 | PCIe Gen2 | x16 | x16 | 13 | Full Length, Full Height slot | Supports up to 225W; single wide cards only | |
| *
Default bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. | |||||||
| x16
PCIe Riser (Optional Secondary) |
Expansion Slots # |
Technology |
Bus Width** |
Connector Width |
Bus Number* |
Form Factor |
Notes |
| 4 | PCIe Gen2 | x16 | x16 | 16 | Full Length, Full Height slot | Supports up to 225W; single wide cards only | |
| *
Default bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. | |||||||
|
| |||||||
| Storage
Controller One of the following depending on Model | Entry Models | HP Smart Array P410i/Zero Memory Controller (RAID 0/1/1+0) |
| Base Models | HP Smart Array P410i/256 MB Controller (RAID 0/1/1+0/5/5+0) | |
| Performance Models | HP Smart Array P410i/512 MB BBWC Controller (RAID 0/1/1+0/5/5+0) | |
| High Efficiency Models | HP Smart Array P410i/Zero Memory Controller (RAID 0/1/1+0) | |
| Available upgrades: 256MB, 512MB with BBWC, 512MB with FBWC, 1G with FBWC, Battery kit upgrade (for the 256MB cache), and Smart Array Advanced Pack (SAAP). | ||
|
| ||
| Storage | Diskette Drive | None Standard |
| Optical Drive One of the following depending on Model | None
Standard on Entry, High Efficiency, and Base Models NOTE: No support on LFF HD Models. | |
| HP Slim SATA DVD RW Optical
Drive Standard on Performance Models NOTE: HP 64GB SSD Optical Drive Option Kit available. See options sections below contact HP for details. |
||
| Hard Drives | None Standard | |
| | ||
| Maximum Internal Storage | Hot Plug SFF SAS | 8.0TB | 16 x 500GB |
| Hot Plug LFF SAS | 6.0TB | 6 x 1TB | |
| | |||
| Interfaces | Serial | 1 |
| Pointing Device (Mouse) | 1 | |
| Graphics | 1 | |
| Keyboard | 1 | |
| VGA | 2 (1 front, 1 back) | |
| Network RJ-45 | 2 | |
| iLO remote management port | 1 | |
| SD slot | 1 | |
| USB 2.0 Ports | 5 total: 2 front, 2 back, 1
internal NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html. |
|
|
|
||
| Graphics |
Integrated ATI ES1000, 32MB video standard
NOTE: Maximum resolution available via iLO 2 remote console is 1280 x 1024. |
|
|
|
| Form Factor | Rack (2U); Height 3.38-inch (8.59 cm); Width: 17.25 (44.54 cm); Depth: 27.25 inches (69.98 cm) |
|
|
|
| HP Insight management software | HP Insight Foundation |
Managing the growing number of servers can be complex and expensive for
your organization. IT managers need to address changing business needs
with tools that meet the challenges of managing today's complex Datacenters.
SmartStart version supported (minimum): SmartStart 8.20 |
| ProLiant Onboard Administrator | HP ProLiant Onboard Administrator (powered by the HP Integrated Lights-Out 2 management processor) simplifies server setup, health monitoring, power and thermal control, and lights-out remote administration of ProLiant ML, DL, and BL servers. HP ProLiant Onboard Administrator functions without additional software, and can be accessed from any location via a web browser. It works hand-in-hand with HP Systems Insight Manager, Insight Control suites, and the Insight Dynamics for ProLiant helping customers unlock the value of the ProLiant platform and deliver the highest possible quality of IT service to the business. See www.hp.com/go/ProLiantOA | |
| HP Insight Control | HP Insight Control, a product option, delivers
essential infrastructure management that can help save time and money by
making it easy to deploy, migrate, monitor, remote control, and optimize
your IT infrastructure through a single, simple management console. Two versions of Insight Control are available, to serve environments requiring either a Linux-based or a Windows-based central management server: HP Insight Control for Linux, and HP Insight Control. See www.hp.com/go/insightcontrol HP Insight Control includes one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/insight. |
|
| HP Insight Dynamics for ProLiant | HP Insight Dynamics
for ProLiant, a product option, is an integrated command center that enables
IT Staff personnel to continuously analyze and optimize a converged infrastructure,
while automating and reducing the cost of common data center tasks by as
much as 40 percent. As a powerfully integrated by design toolkit to accelerate
complex technology projects and simplify daily operations that ultimately
enable IT Staff personnel to dynamically keep pace with the organizations
changing business requirements. It enables them to plan capacity and power
continuously, balance across physical and virtual resources, and ensure
cost-effective high availability. It also enables IT organizations to provision
infrastructure consistently and automatically from pools of shared resources
using a self-service portal. Resources provisioned can range from a single
virtual machine to complex multi-tier environments and their associated
physical and virtual resource requirements. In addition to the previous
functional benefits, it also provides a cost-effective disaster recovery
for physical and virtual environments that works with HP StorageWorks Continuous
Access software for both the Enterprise Virtual Array and the XP storage
array allowing application environments to be reactivated in minutes with
the touch of a button to a remote location. NOTE: For more information, visit: http://www.hp.com/go/insightdynamics |
|
|
|
||
| Industry Standard Compliance | ACPI 2.0 Compliant PCI 2.2 Compliant WOL Support Microsoft® Logo certifications USB 2.0 Support |
| | |
| Security | Power-on password Keyboard password Diskette drive control Diskette boot control QuickLock, Network Server Mode Parallel and serial interface control Administrator's password |
|
|
|
| Security - Trusted Platform Module | Trusted
Platform Module option kit The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to authenticate the server platform. These artifacts can include passwords, certificates and encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user data and to ensure that a server running Windows Server 2008 has not been tampered with while the system was offline. For more information about TPM, including a white paper, go to www.hp.com/go/TPM NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment. NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing the key could result in data loss. |
|
| |
| Server Power Cords | High voltage power
cord ships standard with all part numbers. NOTE: HP ProLiant DL servers no longer ship standard with a 12-foot NEMA 5-15P to C13 power cords (227099-001) that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected to PDU's in data center racks so they now ship standard with only a PDU 6-foot C-14 to C13 power cord (142258-001). If a user wishes to power a ProLiant DL server using a110V receptacle (NEMA-15), the 12-foot NEMA 5-15 to C13 power cord (227099-001) must be ordered separately. Also available: 110 volt 6-Foot NEMA 5-15p to C13 (AF556A). |
| | |
| UPS and PDU Power Cord Matrix |
Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords. |
| | |
| Power Supply | HP has a new design for ProLiant power the new Common Slot Power Supply bay. This design provides the customer with commonality in power supplies across multiple platforms to save on the cost of spares and allows HP to offer multiple power solutions to fit the customers' needs. Many HP ProLiant Servers come with Common Slot, High Efficiency and Right-Size Power Supplies. Common Slot (CS) designates commonality of the power supply across multiple ProLiant servers. HP's new Common Slot power supplies are designed for highest efficiency to provide power efficiency without degrading performance of the ProLiant. Power Supplies will have efficiency ratings up to 94%. There are three Right Size power options available, depending on the configuration of your server. To make sure you select the correct power supply to meet your configuration, we suggest that you use the HP Power Advisor to decide the "Right-Size" for your configuration. All HP Common Slot power sources are UL, CE Mark Compliant, Hot Plug and Redundant. |
| | |
| Common Slot ProLiant |
NOTE: Mixing of power supplies
in the same server is not supported. All power supplies must be of the
same type, all HP 460W, all HP750W, all 1200w 94%, all 1200w 90%, or all
-48V DC. If non-matched power supplies are inserted you will get errors
and operation will fail.
HP's ProLiant Common Slot Power supplies meet multiple Energy Efficiency Initiatives:
NOTE: The 80 PLUS program is a
unique forum that unites electric utilities, the computer industry, and
consumers in an effort to bring energy efficient technology solutions
to the marketplace. 80 Plus independently tests power supply efficiency
and publicly posts the results on 80Plus.org. |
|
| |
| System Fans | Fully redundant hot plug fans
ship standard (N+1). NOTE: One processor models include four fans. Two processor models include six fans. |
|
|
|
| Operating Systems and Virtualization Software Support for ProLiant Servers |
Microsoft
Windows Server |
| NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/ossupport and our driver download page www.hp.com/support/DL380G6. | |
|
|
|
| Rack Airflow Requirements |
Rack 10000 G2 series Cabinets
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: www.hp.com/servers/dl380. | |
|
|
|
| Rack Kit |
Quick deploy rail system provides tool-free support for racks with square or round mounting holes (including Compaq/HP 7000, 9000, 10000 G2 and HP series), with an adjustment range of 24" - 36". The ambidextrous cable management arm can be mounted on either the left or right side for improved cable management. NOTE: High Airflow Inserts (High Air Flow Rack Door Insert for the 7142 Rack (single) - PN: 327281-B21; or High Air Flow Rack Door Insert for the 7142 Rack (6-pack) - PN: 327281-B22) are required to support the HP ProLiant DL380 in 7000 series racks. The DL380 Cable Management Arm is not supported on 7000 series racks. NOTE: Cable management arm must be removed to access hot-plug power supplies when the cable management arm is mounted on the right. |
|
| |
| Telco Rack Support |
Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions at: http://www.hp.com/go/rackandpower |
|
|
|
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and deployment
services for HP servers and storage products. Customers can choose how their factory
solutions are built, tested, integrated, shipped and deployed. |
| | |
| HP Enterprise Configurator | The HP eConfigure-Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. http://www.hp.com/products/configurator. |
| | |
| Service and Support |
HP Care Pack services include coverage for the HP branded hardware options
qualified for the server and purchased at the same time or afterward that
are internal to the enclosure. This also includes the 22" and smaller
external monitors and tower UPS options up to 3kVA. These items will be
covered at the same service level and for the same coverage period as
the server. Coverage of UPS Battery is not included, and standard warranty
terms & conditions apply. For servers or storage systems installed
within a rack, service also covers all HP qualified rack options installed
within the same rack.
Enhanced Service - optimize service level to increase IT performance and availability.
Refer to the information on "Installation & Start-Up" for
service on ProLiant server and Microsoft or Linux O/S per the Customer
Description and/or Data Sheet; to be delivered on a scheduled basis 8am-5pm,
M-F, excluding HP holidays. |
|
|
HPC Interconnects
| NOTE: High Performance Computing (HPC) interconnect technologies are available for the DL380 under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects: http://www.hp.com/techservers/clusters/ucp/index.html |
|
|
| HPC Interconnect | InfiniBand | PCI-X and PCI-Express adapters |
| Gigabit Ethernet | Use embedded ports | |
| Myrinet XP | PCI-X Rev D and Rev E adapters |
|
|
Models
|
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | ||
|
HP DL380 G6 Performance Models | Processor(s) Two of the following depending on Model | (2)
Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333,
HT, Turbo 2/2/3/3) (2) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) |
| Cache Memory | 8MB (1 x 8MB) Level 3 cache | |
| Memory | 12 GB (6 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Network Controller | Two HP NC382i Dual Port Multifunction Gigabit Server Adapters | |
| Storage Controller | HP Smart Array P410i/512MB with BBWC | |
| Hard Drive | None ship standard | |
| Internal Storage | Standard: 8 SFF SAS/SATA
HDD Bays Optional: 16 SFF SAS/SATA HDD Bays | |
| Optical Drive | HP Slim SATA DVD RW drive | |
| Power Supply | (2) 750W Hot Plug Power Supplies | |
| Fans | (6) (N+1 redundancy standard) | |
| Form Factor | Rack (2U), Height 3.38-inch (8.59 cm); Width: 17.25 (44.54 cm); Depth: 27.25 inches (69.98 cm) | |
| | ||
|
HP DL380 G6 Performance Models with ICE standard | Processor(s) Two of the following depending on Model | (2)
Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333,
HT, Turbo 2/2/3/3) (2) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) |
| Cache Memory | 8MB (1 x 8MB) Level 3 cache | |
| Memory | 12 GB (6 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Network Controller | Two HP NC382i Dual Port Multifunction Gigabit Server Adapters | |
| Storage Controller | HP Smart Array P410i/512MB with BBWC | |
| Hard Drive | None ship standard | |
| Internal Storage | Standard: 8 SFF SAS/SATA
HDD Bays Optional: 16 SFF SAS/SATA HDD Bays | |
| Optical Drive | HP Slim SATA DVD RW drive | |
| Power Supply | (2) 750W Hot Plug Power Supplies | |
| Fans | (6) (N+1 redundancy standard) | |
| Insight Control Environment (ICE) | ICE 24x7 support | |
| Form Factor | Rack (2U), Height 3.38-inch (8.59 cm); Width: 17.25 (44.54 cm); Depth: 27.25 inches (69.98 cm) | |
| | ||
|
HP DL380 G6 Base Models | Processor(s) One of the following depending on Model | (1)
Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066,
HT, Turbo 1/1/2/2) (1) Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) (1) Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) |
| Cache Memory | 8MB (1 x 8MB) Level 3 cache | |
| Memory | 6 GB (3 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Network Controller | Two HP NC382i Dual Port Multifunction Gigabit Server Adapters | |
| Storage Controller | HP Smart Array P410i/256MB Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | Standard: 8 SFF SAS/SATA
HDD Bays Optional: 16 SFF SAS/SATA HDD Bays | |
| Optical Drive | None ship standard | |
| Power Supply | (1) 460W Hot Plug Power Supply | |
| Fans | (4) (N+1 redundancy standard) | |
| Form Factor | Rack (2U), Height 3.38-inch (8.59 cm); Width: 17.25 (44.54 cm); Depth: 27.25 inches (69.98 cm) | |
| | ||
|
HP DL380 G6 High Efficiency Models | Processor(s) | (1) Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) |
| Cache Memory | 8MB (1 x 8MB) Level 3 cache | |
| Memory | 4 GB (2 x 2 GB) PC3-10600E (DDR3-1333) Unbuffered DIMMs | |
| Network Controller | Two HP NC382i Dual Port Multifunction Gigabit Server Adapters | |
| Storage Controller | HP Smart Array P410i/Zero Memory Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | Standard:
8 SFF SAS/SATA HDD Bays Optional: 16 SFF SAS/SATA HDD Bays | |
| Optical Drive | None ship standard | |
| Power Supply | (1) 460W Hot Plug Power Supply | |
| Fans | (4) (N+1 redundancy standard) | |
| Form Factor | Rack (2U), Height 3.38-inch (8.59 cm); Width: 17.25 (44.54 cm); Depth: 27.25 inches (69.98 cm) | |
| | ||
|
HP DL380 G6 Entry Models | Processor(s) | (1) Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) |
| Cache Memory | 4MB (1 x 4MB) Level 3 cache | |
| Memory | 4 GB (2 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Network Controller | Two HP NC382i Dual Port Multifunction Gigabit Server Adapters | |
| Storage Controller | HP Smart Array P410i/Zero Memory Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | Standard:
8 SFF SAS/SATA HDD Bays Optional: 16 SFF SAS/SATA HDD Bays | |
| Optical Drive | None ship standard | |
| Power Supply | (1) 460W Hot Plug Power Supply | |
| Fans | (4) (N+1 redundancy standard) | |
| Form Factor | Rack (2U), Height 3.38-inch (8.59 cm); Width: 17.25 (44.54 cm); Depth: 27.25 inches (69.98 cm) |
|
|
Smart Buys
|
The ProLiant Smart Buy program offers a collection of promotional server and option products that are configured with SMB in mind, offered at discounted prices, and positioned for quick delivery. Smart Buy server offers are available for a limited time only. | ||
|
HP S-BUY DL380G6 X5570 8GB | Processor(s) | (2) Intel® Xeon® Processor X5570 (2.93GHz, 95W, DDR3-1333) |
| Cache Memory | 8MB Level 3 cache | |
| Memory | 8GB RDIMM (2x HP 4GB 2Rx4 PC3-10600R-9 Kit) | |
| Network Controller | (2) HP NC382i Integrated Dual Port Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410i/512MB BBWC Controller | |
| Hard Drive | None included, supports up to 6LFF | |
| Internal Storage | SATA maximum -14.0TB, SAS maximum - | |
| Optical Drive | None included | |
| Power Supply | (2) HP 750W CS HE Power Supply Kits | |
| Fans | 6 fans - Fully redundant Hot Plug fans ship standard (N+1) | |
| Form Factor | Rack (2U), (3.38 in./8.59cm) | |
| Server Management | iLO Advanced | |
| | ||
|
HP S-BUY DL380G6 E5540 8GB | Processor(s) | (2) Intel® Xeon® Processor E5540 (2.53GHz, 80W, DDR3-1066) |
| Cache Memory | 8MB Level 3 cache | |
| Memory | 8GB RDIMM (2Rx4 PC3-10600ER (DDR-1333) Registered DIMMs) | |
| Network Controller | (2) HP NC382i Integrated Dual Port Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410i/512MB BBWC Controller | |
| Hard Drive | None included, supports up to 8SFF | |
| Internal Storage | SATA maximum -14.0TB, SAS maximum - | |
| Optical Drive | HP Slim SATA DVD Optical Drive | |
| Power Supply | (2) HP 750W CS HE Power Supply Kits | |
| Fans | 6 fans - Fully redundant Hot Plug fans ship standard (N+1) | |
| Form Factor | Rack (2U), (3.38 in./8.59cm) |
|
|
Configuration Information - Factory Integrated Models
|
NOTE: This section lists some of the steps required to configure a Factory
Integrated Model. To ensure only valid configurations are ordered, HP recommends
the use of an HP approved configurator. Contact your local sales representative
for information on CTO product offerings and requirements. | |||
| Step 1: Base Configuration (choose one of the following configurable models) | |||
| Models | HP DL380R06 CTO Chassis |
494329-B21 | |
| Factory Integrated Model ships with: | |||
| Two HP NC382i
Dual Port Multifunction Gigabit Server Adapters
System Fans - 4 (2 additional fans
included with second processor) | |||
| HP DL380R06 LFF CTO Chassis | 516919-B21 | ||
| Factory Integrated Model ships with: | |||
| Two HP NC382i
Dual Port Multifunction Gigabit Server Adapters
Drive Cage - 6-LFF | |||
| | |||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processors | Quad-Core Processors | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO | 492136-L21 | |
| Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO |
492131-L21
|
|
| Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800), FIO |
500089-L21
|
|
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO |
492239-L21
|
|
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2), FIO |
500087-L21
|
|
| Intel® Xeon® Processor L5530 (2.40 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2), FIO | 578388-L21 | |
| Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO |
492237-L21
|
|
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO | 492244-L21 | |
| Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO |
492234-L21
|
|
| Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO | 492232-L21 | |
| Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO |
500094-L21
|
|
| Dual-Core Processors | ||
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO | 500085-L21 | |
| Base Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit |
500656-B21
|
|
| HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21
|
|
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit |
500660-B21
|
|
| HP 8GB 2Rx4 PC3-8500R-7 Kit |
516423-B21
|
|
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| HP 16GB 4Rx4 PC3-8500R-7 Kit | 500666-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE:
All DDR3 memory option kits consist of one DIMM per kit. For detailed memory
configuration rules and guidelines, please use the Online DDR3 Memory Configuration
Tool: www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient. |
||
| Power Supplies | NOTE: Refer to HP Power Advisor when selecting a power supply for your configuration, www.hp.com/go/hppoweradvisor. Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at "www.hp.com/go/proliant-energy-efficient" or www.hp.com/go/hppoweradvisor | |
| HP 460W CS HE Power Supply Kit | 503296-B21 | |
| HP 750W CS HE Power Supply Kit | 512327-B21 | |
| HP 1200W CS HE Power Supply Kit | 500172-B21 | |
| HP 1200W CS Platinum Power Supply Kit | 578322-B21 | |
| HP 1200W-48V DC Common Slot Power Supply | 437573-B21 | |
| NOTE:
DC power supplies contain a -48V DC power cord designed for in rack
DC power rectifiers. NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. |
||
|
|
||
| Step 3: Choose Additional Factory Integratable Options (only one of the following from each list unless otherwise noted) | ||
| Controllers | NOTE: If Additional Memory Cache Module or Controller is Required please pick one of the following: | |
| HP 256 MB P-series
cache module FIO NOTE: This is an option for the HP Smart Array P410i controller (P410i is standard integrated controller). |
534108-B21 | |
| Battery Kit upgrade NOTE: This is an option for the HP Smart Array P410i Controller (P410i is standard integrated controller). NOTE: To enable BBWC on the 256MB cache on P410i. |
462969-B21 | |
| 512MB BBWC NOTE: This is an option for the HP Smart Array P410i Controller (P410i is standard integrated controller). NOTE: Battery included. When used with the embedded HP Smart Array P410i controller. |
462967-B21 | |
| 512MB Flash Backed
Write Cache NOTE: This is an option for the HP Smart Array P410i Controller (P410i is standard integrated controller). |
534916-B21 | |
| 1G Flash Backed Write
Cache NOTE: This is an option for the HP Smart Array P410i Controller (P410i is standard integrated controller). |
534562-B21 | |
| HP Smart Array P212/256 MB w/ Battery FIO | 491191-B21 | |
| HP Smart Array P410/256 MB w/ Battery FIO | 491195-B21 | |
| HP Smart Array P411/256 MB w/ Battery FIO | 491193-B21 | |
| Performance Packs |
The HP ProLiant DL380 performance packs are necessary to configure a
HP ProLiant DL380 Performance Model. HP ProLiant DL380 Performance model
includes the latest performance technologies and enterprise class availability
features pre-installed for convenience and value.
NOTE: Must also select Slimline SATA DVD RW Optical Drive (481043-B21) to achieve parity to DL380 High Performance Models. |
|
| HP DL380G6 2.6 HPM FIO Perf Pack |
500583-B21
|
|
| HP DL380G6 2.8 HPM FIO Perf Pack |
500584-B21
|
|
|
|
||
| Step 4: Choose Additional Options for Factory Integration |
| NOTE: For additional options, please refer to the "Core Options and Additional Options" section below. |
|
|
Core Options
| NOTE: Some options may not be integrated at the factory. Contact your local sales representative for additional information. | ||
|
|
||
| HP ProLiant DL380 G6 Unique Options | HP StorageWorks RDX160 Removable
Disk Backup System DL Server Module NOTE: Mounts in DL380 G6 second drive cage slot (160GB of Disk Storage) |
AP724A |
| HP StorageWorks RDX320 Removable
Disk Backup System DL Server Module NOTE: Mounts in DL380 G6 second drive cage slot (320GB of Disk Storage) |
AP725A | |
| HP StorageWorks RDX500 Removable
Disk Backup System DL Server Module NOTE: Mounts in DL380 G6 second drive cage slot (500GB of Disk Storage) |
AP726A | |
| HP 8SFF CAGE 380G6 NOTE: Second drive cage installation replaces internal optical bay. NOTE: Second drive cage requires second controller or HP SAS Expander Card (468406-B21). |
516914-B21 | |
| HP DL380G6 PCI-E 3 Slot 1x8 2x4 Riser Kit | 500579-B21 | |
| HP Assy Fan Kit | 581031-B21 | |
|
|
||
| Processors | Quad-Core Processors | |
| Intel® Xeon® Processor
E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) |
492136-B21 | |
| Intel® Xeon® Processor
E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) |
492131-B21 | |
| Intel® Xeon® Processor
L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800) |
500089-B21 | |
| Intel® Xeon® Processor
E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) |
492239-B21 | |
| Intel® Xeon® Processor
L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) |
500087-B21 | |
| Intel® Xeon® Processor L5530 (2.40 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) | 578388-B21 | |
| Intel® Xeon® Processor
E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) |
492237-B21 | |
| Intel® Xeon® Processor
E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) |
492244-B21 | |
| Intel® Xeon® Processor
X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) |
492234-B21 | |
| Intel® Xeon® Processor
X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) |
492232-B21 | |
| Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | 500094-B21 | |
| Dual-Core Processors | ||
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) | 500085-B21 | |
|
|
||
|
Memory |
Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit |
500656-B21
|
|
| HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21
|
|
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit |
500660-B21
|
|
| HP 8GB 2Rx4 PC3-8500R-7 Kit |
516423-B21
|
|
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| HP 16GB 4Rx4 PC3-8500R-7 Kit | 500666-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient |
||
|
|
||
|
Optical Drives |
HP Slim SATA DVD RW Optical Drive NOTE: Included in performance models. |
481043-B21
|
| HP Slim SATA DVD-ROM Optical Drive | 481041-B21 | |
| HP External USB CD/DVD R/RW Option
Drive NOTE: There is no optical drive support in the LFF Hard Drive models. |
FS943AA | |
|
|
||
| Hard Drives | NOTE: The components
of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and
the server backplane) should operate at the same data transfer rate or the
system bandwidth will be negotiated down to an acceptable level for all
components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. |
|
| SAS Hot Plug SFF Enterprise (ENT) Drives | ||
| HP 300GB 6G SAS 10K SFF DP ENT HDD |
507127-B21
|
|
| HP 300GB 3G SAS 10K SFF DP ENT HDD |
492620-B21
|
|
| HP 146GB 6G SAS 15K SFF DP ENT HDD | 512547-B21 | |
| HP 146GB 6G SAS 10K SFF DP ENT HDD |
507125-B21
|
|
| HP 146GB 3G SAS 10K SFF DP ENT HDD |
418367-B21
|
|
| HP 146GB 3G SAS 15K SFF DP ENT HDD |
504062-B21
|
|
| HP 72GB 6G SAS 15K SFF DP ENT HDD | 512545-B21 | |
| HP 72GB 3G SAS 15K SFF DP ENT HDD |
418371-B21
|
|
| HP 72GB 3G SAS 10K SFF DP ENT HDD |
384842-B21
|
|
| SAS Hot Plug 3.5" Enterprise
(ENT) Drives |
||
| HP 600GB 6G SAS 15K 3.5"
DP ENT HDD |
516828-B21 | |
| HP 450GB 6G SAS 15K 3.5" DP ENT HDD | 516816-B21 | |
| HP 450GB 3G SAS 15K 3.5" DP ENT HDD | 454232-B21 | |
| HP 300GB 6G SAS 15K 3.5" DP ENT HDD | 516814-B21 | |
| HP 300GB 3G SAS 15K 3.5"
DP ENT HDD |
416127-B21 | |
| HP 146GB 3G SAS 15K 3.5"
DP ENT HDD |
384854-B21 | |
| SAS Hot Plug SFF Midline (MDL) Drives | ||
| HP 500GB 6G SAS 7.2K SFF DP MDL
HDD |
507610-B21 | |
| SAS Hot Plug 3.5" Midline
(MDL) Drives |
||
| HP 1TB 3G SAS 7.2K 3.5" DP
MDL HDD |
461137-B21 | |
| HP 750GB 3G SAS 7.2K 3.5"
DP MDL HDD |
461135-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12244_na/12244_na.html |
||
| SATA Hot Plug SFF Midline (MDL)
Drives |
||
| HP 500GB 3G SATA 7.2K 2.5in MDL
HDD |
507750-B21 | |
| HP 160GB 3G SATA 7.2K 2.5in MDL
HDD |
530888-B21 | |
| SATA Hot Plug 3.5" Midline
(MDL) Drives |
||
| HP 1TB 3G SATA 7.2K 3.5"
MDL HDD |
454146-B21 | |
| HP 750GB 3G SATA 7.2K 3.5"
MDL HDD |
458930-B21 | |
| HP 500GB 3G SATA 7.2K 3.5"
MDL HDD |
458928-B21 | |
| HP 250GB 3G SATA 7.2K 3.5"
MDL HDD |
458926-B21 | |
| SATA Hot Plug 3.5" Entry
(ETY) Drives |
||
| HP 160GB 3G SATA 7.2K 3.5"
ETY HDD |
458945-B21 |
|
| SATA Hot Plug SFF Entry (ETY)
Drives |
||
| HP 250GB 3G SATA 5.4K SFF ETY
HDD |
460355-B21 | |
| HP 120GB 1.5G SATA 5.4K SFF ETY
HDD |
458924-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13021_na/13021_na.html |
||
| SATA Hot Plug Midline (MDL)
Solid State Drives |
||
| HP 60GB 3G SATA 2.5in MDL 1y Wty
SSD |
572071-B21 | |
| HP 120GB 3G SATA 2.5in MDL 1y
Wty SSD |
572073-B21 | |
| SATA Hot Plug 3.5" Midline
(MDL) Solid State Drives |
||
| HP 60GB 3G SATA 3.5in MDL 1y Wty
SSD |
570761-B21 | |
| HP 120GB 3G SATA 3.5in MDL 1y Wty SSD | 570763-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13415_na/13415_na.html |
||
|
|
||
| Communications | HP NC112T PCIe Gigabit Server Adapter |
503746-B21
|
| HP NC360T PCI Express Dual Port Gigabit Server Adapter |
412648-B21
|
|
| HP NC364T PCI Express Quad Port
Gigabit Server Adapter NOTE: Does not support Windows 2000. |
435508-B21
|
|
| HP NC373F PCI Express Multifunction Gigabit Server Adapter |
394793-B21
|
|
| HP NC373T PCI Express Multifunction Gigabit Server Adapter |
394791-B21
|
|
| HP NC375T PCI Express Quad Port Gigabit Server Adapter | 538696-B21 | |
| HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter |
458492-B21
|
|
| HP NC522SFP Dual Port 10GbE Server
Adapter NOTE: A minimum of two gigabyte (2 GB) of server memory is required per each NC522SFP adapter. NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately. |
468332-B21
|
|
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs |
|
|
Riser Cage Options |
HP DL380G6 PCI-E 3 Slot 1x8 2x4 Riser Kit |
500579-B21
|
| HP DL38X PCI-X riser kit (1) PCI-X, (1) x8, (1) x4) | 494322-B21 | |
| HP DL38X (1) x16 PCI-E riser kit | 494323-B21 | |
| HP DL38X (2) x8 Dual Port Riser
Kit NOTE: This riser card will support Qty 2 of 10Gbe NICs. |
494326-B21 | |
|
|
||
| Power Supplies | CAUTION: In ProLiant Servers that have more than one power slot (bay), only same size power supplies are recommended. If non-matched power supplies are inserted you will get errors and operation will fail. | |
| HP 460W CS HE Power Supply Kit |
503296-B21
|
|
| HP 750W CS HE Power Supply Kit |
512327-B21
|
|
| HP 1200W CS HE Power Supply Kit |
500172-B21
|
|
| HP 1200W CS Platinum Power Supply Kit | 578322-B21 | |
| HP 1200W-48V DC Common Slot Power
Supply NOTE: DC power supplies contain a -48V DC power cord designed for in rack DC power rectifiers. |
437573-B21 | |
| NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. |
|
|
Additional Options
| HP Insight Software | HP Insight Control server deployment | |
| HP Insight Control server deployment, Electronic License including 1 year of 24x7 Technical Support and Updates | T9082AAE | |
| NOTE: Electronic and Flexible-Quantity
licenses can be used to purchase multiple licenses with a single activation
key. NOTE: Electronic software is available in all countries except China and Japan. Customers in China and Japan should order the physical equivalent. NOTE: Customer will receive a license entitlement certificate. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: Licenses ship without media. The HP Insight Control Media Kit can be ordered separately, or can be downloaded at: http://www.hp.com/go/insightupdates. NOTE: For additional license options please see the Insight Control QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12631_na/12631_na.html |
||
| HP Insight Control for Linux | ||
| HP Insight Control for Linux, 1-server license, including one year of 24x7 Technical Support and Updates, Electronic | T9084BAE | |
| HP Insight Control for Linux, No Media, 1-Server license, including one year of 24x7 Technical Support and Updates | 464423-B22 | |
| HP Insight Control for Linux, Media pack
(DVD) - No licenses included NOTE: Media pack DVD contains the ISO image for HP Insight Control for Linux, HP Systems Insight Manager, HP Insight Control power management, HP Insight Control virtual machine management, and an integrated installer. Servers must be acquired separately. |
464422-B22 | |
| NOTE: Licenses ship without
media. The HP Insight Control Media Kit can be ordered separately, or can
be downloaded at: http://www.hp.com/go/insightupdates.
NOTE: Electronic software is available in all countries except China and Japan. Customers in China and Japan should order the physical equivalent. NOTE: Electronic and Flexible-Quantity licenses can be used to purchase multiple licenses with a single set of activation keys. NOTE: For additional License Kits, including electronic licensing options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_na/13019_na.html |
||
| HP Integrated Lights-Out Advanced | ||
| HP Integrated Lights-Out Advanced, No Media,
1-Server License, including 1 year of 24x7 Technical Support and Updates NOTE: This license allows 1 server to be deployed and managed via HP iLO Advanced. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service NOTE: For additional license kits, including electronic delivery options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12362_na/12362_na.html |
512485-B21 | |
| HP Insight Rapid Deployment software | ||
| HP Insight Rapid Deployment software No Media
1-Server License including 1 year of 24x7 Technical Support and Updates NOTE: This license allows 1 server to be deployed and managed via RDP. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service NOTE: For additional license kits, including electronic delivery options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.html |
452151-B21 | |
|
|
||
|
Drive Cage Options |
HP 8SFF CAGE 380G6 NOTE: Second drive cage installation replaces internal optical bay. NOTE: Second drive cage requires second controller or HP SAS Expander Card (468406-B21). |
516914-B21
|
|
|
||
|
Security |
HP Trusted Platform Module Option Kit |
488069-B21
|
|
|
||
| Storage Controllers | SAS Controllers | |
| Smart Array P800 Controller | ||
| HP Smart Array P800/512 BBWC Controller NOTE: The HP ProLiant DL380 G6 does not allow the HP Smart Array P800/512 BBWC Controller to support the internal drives. It is for external drive support only. |
381513-B21
|
|
| Smart Array P212 Controller | ||
| HP Smart Array P212/Zero Memory Controller |
462828-B21
|
|
| HP Smart Array P212/256 MB Controller | 462834-B21 | |
| Smart Array P410 Controller | ||
| HP Smart Array P410/256 MB Controller |
462862-B21
|
|
| HP Smart Array P410/512 MB with BBWC Controller |
462864-B21
|
|
| Smart Array P411 Controller | ||
| HP Smart Array P411/256 MB Controller |
462830-B21
|
|
| HP Smart Array P411/512 MB with BBWC Controller |
462832-B21
|
|
| Optional Upgrades | ||
| 256 MB Cache Module NOTE: Supported on HP Smart Array P212 Controller and as an upgrade on HP Smart Array P410i (Zero Memory). |
462968-B21 | |
| 512MB BBWC | 462967-B21 | |
| 1G Flash Backed Write Cache NOTE: Supported on the Smart Array P410i Controller only. |
534562-B21 | |
| 512MB Flash Backed Write Cache NOTE: Supported on the Smart Array P410i Controller only. |
534916-B21 | |
| Battery Kit upgrade NOTE: To enable BBWC on the 256MB cache. NOTE: Supported on HP P410i Smart Array (integrated), HP Smart Array P212 Controller, HP Smart Array P410 Controller, and HP Smart Array P411 Controller only. |
462969-B21 | |
| HP 8484 to Mini SAS 33in Cable
Assy NOTE: Needed to support internal drives on the HP ProLiant DL380 G6 with the Smart Array P800 Controller. |
591734-B21 | |
| HP Smart Array Advanced Pack No
Media 1-Server license including 1yr 24x7 Technical Support NOTE: This part number can be used to purchase a single license or to order multiple licenses with a single activation key. Customers will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Include one year of 24x7 HP Software Technical Support Services. |
516471-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12616_na/12616_na.html (Smart Array P800 Controller) http://h18000.www1.hp.com/products/quickspecs/13203_na/13203_na.html (Smart Array P212 Controller) http://h18000.www1.hp.com/products/quickspecs/13201_na/13201_na.html (Smart Array P410 Controller) http://h18000.www1.hp.com/products/quickspecs/13202_na/13202_na.html (Smart Array P411 Controller) http://h18000.www1.hp.com/products/quickspecs/13200_na/13200_na.html (Smart Array Advanced Pack) |
||
| SAS Controller Options | ||
| HP SAS Expander Card | 468406-B21 | |
| NOTE:
Please see the QuickSpecs for Technical Specifications and additional information: http://h18004.www1.hp.com/products/quickspecs/13232_na/13232_na.html (SAS Expander Card) |
||
| SAS HBA | ||
| HP SC08Ge Host Bus Adapter NOTE: For use with additional 8 SFF drive cage (516914-B21). |
488765-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information: http://h18004.www1.hp.com/products/quickspecs/13082_na/13082_na.html (SC08Ge HBA) |
||
| SCSI HBA | ||
| HP SC11Xe Host Bus Adapter NOTE: Recommended HBA for SCSI tape drive connect. |
412911-B21
|
|
|
NOTE: Please see the QuickSpecs for
additional information: |
||
|
|
||
| Power Cords | NOTE: HP ProLiant servers ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). | |
| Nema 5-15P to IEC320-C13, low voltage (6 ft/2 m) | AF556A |
|
| HPC Specific Options | HP IB 4X QDR PCI-e G2 Dual Port HCA |
517721-B21
|
| HP IB 4X QDR CX-2 PCI-e G2 Dual Port HCA | 592520-B21 | |
| HP IB 4X DDR CX-2 PCI-e G2 Dual Port HCA | 592521-B21 | |
| HP 4X QDR PCI-e G2 QLogic InfiniBand Dual Port HCA | 583211-B21 | |
| NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13078_na/13078_na.html | ||
|
| ||
| Tape Storage |
NOTE: For the complete listing of Tape Drive offerings, please
see: For recommended tape drive offerings for this ProLiant server see the following: |
|
| Tape Drives | ||
| USB Rack-Mount Tape Solutions | ||
| HP StorageWorks 1U USB Rack-Mount
Kit with one DAT 160 USB Tape Drive NOTE: Pre-configured with one DAT 160 USB tape drive. |
AG703A
|
|
| HP StorageWorks DAT 160 SAS External
Tape Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A). |
Q1588A | |
| HP StorageWorks 1U USB Rack-Mount Kit with one DAT 320 USB Tape Drive | AP835A | |
| SAS Rack-Mount
Tape Solutions NOTE: HP recommends purchasing the HP Smart Array P212 Controller (462828-B21) for a dedicated SAS HBA for tape. |
||
| HP StorageWorks DAT 320 WW SAS
Internal Tape Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A). |
AJ830A
|
|
| HP StorageWorks LTO-2 Ultrium
448 SAS Internal Tape Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A). |
DW085A
|
|
| HP StorageWorks LTO-3 Ultrium
920 SAS Internal Tape Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A). |
EH847A
|
|
| HP StorageWorks 1U SAS Rack-Mount
Kit with one LTO-4 Ultrium 1760 NOTE: Pre-configured with one LTO-4 Ultrium 1760 SAS tape drive. |
EH946A
|
|
| HP StorageWorks LTO-4 Ultrium
1840 SAS Internal Tape Drive NOTE: Mounts inside the 3U SAS Rack-Mount Kit (AG576A). |
EH860A | |
| NOTE: For an up-to-date listing of the latest O/S and software support details for HP tape drives, please visit: http://www.hp.com/go/connect. | ||
| HP StorageWorks 1/8 G2 Tape Autoloader | ||
| HP StorageWorks 1/8 G2 LTO-3 Ultrium
920 SAS Autoloader NOTE: Requires the HP StorageWorks 1/8 G2 Tape Autoloader Rack Kit. |
AH558A | |
| HP StorageWorks 1/8 G2 LTO-4 Ultrium
1760 SAS Tape Autoloader NOTE: Requires the HP StorageWorks 1/8 G2 Tape Autoloader Rack Kit (AH166A). |
AK377A | |
| NOTE: Please reference the Tape Autoloader QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution. | ||
| HP StorageWorks MSL2024 Tape Library | ||
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SAS Drive Library | AK378A | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SAS Drive Library | AH559A | |
| HP StorageWorks MSL4048 Tape Library | ||
| HP StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SAS Drive Library | AK380A | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SAS Drive Library | AH560A | |
| NOTE: Please reference the MSL Tape Library QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs. | ||
|
|
||
| Backup & Recovery Software | HP Data Protector Express | |
| HP Data Protector Express 4.0 SP1 Backup Server |
BB117BA
|
|
| HP Data Protector Express 4.0 SP1 for Microsoft Small Business Server | BB118BA | |
| HP Data Protector Express Backup Server 4.0 SP1Upgrade from Data Protector Express Single Server Edition | BB117BT | |
| NOTE: Only of these Data Protector Express base products is required. For more information on Data Protector Express and to see available options please visit: http://www.hp.com/go/dataprotectorexpress | ||
|
|
||
| Disk-Based Backup | RDX Removable Disk Backup | |
| HP StorageWorks
RDX160 Removable Disk Backup System DL Server Module NOTE: Mounts in DL380 G6 media bay (160GB of Disk Storage) |
AP724A
|
|
| HP StorageWorks RDX320 Removable
Disk Backup System DL Server Module NOTE: Mounts in DL380 G6 media bay (320GB of Disk Storage) |
AP725A | |
| HP StorageWorks RDX500 Removable
Disk Backup System DL Server Module NOTE: Mounts in DL380 G6 media bay (500GB of Disk Storage) |
AP726A | |
| NOTE: Please see
the HP RDX Removable Disk Backup System QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13036_na/13036_na.html |
||
| D2D Backup | ||
| HP StorageWorks D2D2502i Backup
System NOTE: 2 TB raw capacity/1.5 TB useable capacity. |
EJ001A
|
|
| HP StorageWorks D2D2504i Backup
System NOTE: 4 TB raw capacity/3 TB useable capacity. |
EJ002A
|
|
| NOTE: Please see the HP D2D Backup Systems QuickSpecs for additional information: http://www.hp.com/go/d2d | ||
|
|
||
| StorageWorks Options | StorageWorks Fibre Channel HBA | |
| NOTE: For the complete listing of Fibre Channel Host Bus Adapters for Windows 2000, Windows Server 2003 and Linux, please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html | ||
| Brocade Fibre Channel HBAs |
||
| HP StorageWorks 81B PCI-e FC HBA
Single Port |
AP769A
|
|
| HP StorageWorks 82B PCI-e FC HBA
Dual Port |
AP770A
|
|
| HP StorageWorks 41B 4Gb PCI-e
FC HBA |
AP767A | |
| HP StorageWorks 42B 4Gb Dual-Port
PCI-e FC HBA |
AP768A | |
| Emulex Fibre Channel HBAs |
||
| HP StorageWorks 81E PCI-e FC HBA
Single Port |
AJ762A |
|
| HP StorageWorks 82E PCI-e FC HBA
Dual Port |
AJ763A |
|
| HP StorageWorks FC2142 4Gb PCI-e
HBA |
A8002A |
|
| HP StorageWorks FC2242 Dual Channel
4Gb PCI-e HBA |
A8003A |
|
| QLogic Fibre Channel HBAs |
||
| HP StorageWorks 81Q PCI-e FC HBA
Single Port |
AK344A | |
| HP StorageWorks 82Q PCI-e FC HBA Dual Port | AJ764A | |
| HP StorageWorks FC1142 4Gb PCI-e HBA | AE311A | |
| HP StorageWorks FC1242 Dual Channel 4Gb PCI-e HBA | AE312A | |
|
|
||
|
HP StorageWorks Modular Smart Array |
MSA SAN Storage Arrays | |
| HP StorageWorks 50 Modular Smart
Array |
364430-B21 | |
| NOTE: Please see the Modular Smart Array 50 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/12245_na/12245_na.html | ||
| HP StorageWorks 60 Modular Smart Array | 418408-B21 | |
| NOTE:
Please see the Modular Smart Array 60 QuickSpecs for additional information
including configuration steps and additional options needed for a complete
solution at: http://h18000.www1.hp.com/products/quickspecs/12627_na/12627_na.html |
||
| HP StorageWorks 70 Modular Smart
Array |
418800-B21 | |
| NOTE:
Please see the Modular Smart Array 70 QuickSpecs for additional information
including configuration steps and additional options needed for a complete
solution at: http://h18000.www1.hp.com/products/quickspecs/12652_na/12652_na.html |
||
| HP StorageWorks D2600 Disk Enclosure
|
AJ740A | |
| NOTE: Please see the D2600 Disk Enclosure QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/13404_na/13404_na.html | ||
| HP StorageWorks D2700 Disk Enclosure | AJ741A | |
| NOTE: Please see the D2700 Disk Enclosure QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/13404_na/13404_na.html | ||
| HP 2012sa Single Controller Modular
Smart Array |
AJ752A | |
| HP 2012sa Dual Controller Modular
Smart Array |
AJ753A | |
| NOTE: Please see
the Modular Smart Array 2000sa QuickSpecs for additional options and configuration
information at: http://h18000.www1.hp.com/products/quickspecs/13045_na/13045_na.html |
||
|
|
||
|
Uninterruptible Power Systems |
HP Rack-mountable UPS | |
| HP R1500 G2 UPS | ||
| HP, R1.5kVA UPS, 1U |
AF419A
|
|
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12507_na/12507_na.html | ||
| NOTE: For additional information on HP Uninterruptable Power Systems please go to: www.hp.com/servers/rackups. | ||
|
|
||
|
Power Distribution Units |
Monitored PDUs | |
| HP Monitored Power Distribution Unit: Full Rack Version | ||
| HP 17.3 kVA S2324 Monitored PDU- dual input, 3Ø24A |
AF503A
|
|
| HP 8.6 kVA S1324 Monitored PDU- single input, 3Ø, 24A |
AF504A
|
|
| HP 16.6 kVA S2140 Monitored PDU- dual input, 1Ø, 40A |
AF505A
|
|
| HP 8.3 S1140 Monitored PDU- single input, 1Ø, 40A |
AF506A
|
|
| HP Monitored Power Distribution Unit: Half Rack Version | ||
| HP 4.9 kVA S124 Monitored PDU- single input, 1Ø, 24A |
AF914A
|
|
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12118_na/12118_na.html | ||
|
|
||
|
HP Rack Series |
HP Rack 5000 Series (Graphite Metallic) | |
| HP 5642 Rack-Unassembled | 358254-B21 | |
| NOTE:
Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.html |
||
| HP Rack 10000 G2 Series (Carbon/Graphite Metallic) | ||
| S10614 (14U) Rack Cabinet - Shock Pallet | 292302-B22 | |
| 10642 G2 (42U) Rack Cabinet - Pallet | AF001A | |
| 10642 G2 (42U) Rack Cabinet - Shock Pallet |
AF002A
|
|
| 10642 G2 (42U) Rack Cabinet - Crated |
AF003A
|
|
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet | AF004A | |
| 10636 G2 (36U) Rack Cabinet - Pallet |
AF011A
|
|
| 10636 G2 (36U) Rack Cabinet - Shock Pallet |
AF012A
|
|
| 10636 G2 (36U) Rack Cabinet - Crated |
AF013A
|
|
| 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet |
AF014A
|
|
| 10622 G2 (22U) Rack Cabinet - Pallet |
AF021A
|
|
| 10622 G2 (22U) Rack Cabinet - Shock Pallet |
AF022A
|
|
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Shock Pallet | AF034A | |
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Pallet | AF038A | |
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Pallet |
AF041A
|
|
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Shock Pallet |
AF042A
|
|
| 10647 G2 (47U) Rack Cabinet - Pallet |
AF031A
|
|
| 10647 G2 (47U) Rack Cabinet 1200mm
Deep - Shock Pallet NOTE: Due to handling and shipping requirements, AF044A is only orderable through HP Factory Express. It is not for direct sales. Customer site surveys are required before an order is approved. CTO orders may require additional lead time. |
AF044A | |
| 10647 G2 (47U) Rack Cabinet 1200mm Deep - Pallet | AF045A | |
| NOTE: It is mandatory
to use a shock pallet when shipping racks with equipment installed. NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). |
||
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html | ||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
|
||
| HP Rack Options | Keyboards and Monitors | |
| TFT7600 Rackmount Keyboard Monitor |
AG052A
|
|
| HP TAA TFT7600 Rkmntkybd 17in Monitor | AG067A | |
| 1U Rackmount Keyboard with USB |
AG072A
|
|
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| HP KVM Switch Options | ||
| 2x1x16 IP Console Switch with Virtual Media | AF601A | |
| 4x1x16 IP Console Switch with Virtual Media | AF602A | |
| 1x1Ex8 KVM IP Console Switch G2 with Virtual Media and CAC | AF620A | |
| 2x1Ex16 KVM IP Console Switch G2 with Virtual Media and CAC | AF621A | |
| 4x1Ex32 KVM IP Console Switch G2 with Virtual Media and CAC | AF622A | |
| 2x16 Server Console Switch with Virtual Media | AF600A | |
| 0x2x16 KVM Server Console G2 Switch with Virtual Media and CAC | AF618A | |
| 0x2x32 KVM Server Console G2 Switch with Virtual Media and CAC | AF619A | |
| PS/2 Virtual Media Interface Adapter,
1 pack NOTE: Requires PS/2 and one USB port on server. |
AF604A | |
| Server console switch 0x2x8 | AF616A | |
| Server console switch 0x2x16 | AF617A | |
| PS/2 Interface Adapter, 1 pack | 262588-B21 | |
| PS/2 Interface Adapter, 8 pack | 262587-B21 | |
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x4 Console Switch | ||
| HP PS2 Server Console Cable, 6 foot, 2-Pack |
AF611A |
|
| HP USB Server Console Cable, 6
foot, 2-Pack NOTE: Required for supporting USB peripherals. |
AF612A |
|
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
| HP Serial Console Server Options |
AF613A |
|
| HP 16 Port Serial Console Server | AF101A | |
| HP 48 Port Serial Console Server | AF102A | |
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack | AF103A | |
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack | AF110A | |
| NOTE: Cat5e cables
are required to connect Serial Adapters to Serial Console Servers. Additional
Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. |
||
|
|
||
| USB and SD Options | HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver) |
DC172B
|
| 1.44MB External USB Floppy Drive |
DC141B
|
|
| HP USB 04 Standard Keyboard |
DT528A#ABA
|
|
| HP 4GB USB Flash Media Drive Key NOTE: Blank USB and SD media device is supported for use withVMware and Citrix. USB/SD media must be installed in the internal slot of the ProLiant server. Learn more at: http://www.hp.com/go/proliantvirtualization. |
580385-B21 | |
| HP 4GB SD Flash Media Kit NOTE: Blank USB and SD media device is supported for use withVMware and Citrix. USB/SD media must be installed in the internal slot of the ProLiant server. Learn more at: http://www.hp.com/go/proliantvirtualization. |
580387-B21 | |
|
|
||
| Service
and Support Offerings (HP Care Pack Services) |
Hardware Services On-site Service | |
| 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic |
U4544E
|
|
| 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4545E
|
|
| Hardware Services 6-Hour Call to Repair On-site Service | ||
|
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4546E
|
|
| Installation & Start-up Services | ||
| Hardware Installation, Electronic |
U4554E
|
|
| Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays, Electronic |
U4555E
|
|
| Installation and Startup for Essentials Rapid Deployment Pack, Electronic |
U5683E
|
|
| Support Plus | ||
| Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic |
U4556E
|
|
| Support Plus 24 | ||
| Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U4557E
|
|
| Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U6312E
|
|
| Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U8334E
|
|
| NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack |
|
|
Memory
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
| DDR3
memory population guidelines
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
NOTES:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
DIMM slot and configuration diagrams
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory configuration (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory plus optional memory (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Standard memory replaced with optional memory (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| UDIMM maximum configuration (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Standard memory replaced with optional memory (2 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| UDIMM maximum configuration
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| NOTE: Capacity references are rounded to the common Gigabyte values.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Following are memory options available from HP: | ||
| Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit | 500656-B21 | |
| HP 4GB 2Rx4 PC3-10600R-9 Kit | 500658-B21 | |
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit | 500660-B21 | |
| HP 8GB 2Rx4 PC3-8500R-7 Kit | 516423-B21 | |
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| HP 16GB 4Rx4 PC3-8500R-7 Kit | 500666-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient |
||
|
|
Storage
![]() |
1-8
|
Eight SFF SAS hot plug hard drive bays |
![]() |
1-16 | Sixteen SFF SAS hot plug hard
drive bays NOTE: This configuration does not support optical drive. |
![]() |
1-6 | Six LFF SAS hot plug hard drive
bays NOTE: This configuration does not support optical drive. |
| Drive Support | |||
|
| |||
|
Quantity |
Position |
Controller | |
|
Removable Media | |||
| HP Slim SATA DVD RW Optical Drive NOTE: Included in performance models. |
Only 1 available removable media bay |
Slimline bay | Integrated
SATA NOTE: Optional |
| HP Slim SATA DVD-ROM Optical Drive | Only
1 available removable media bay |
Slimline bay | Integrated
SATA NOTE: Optional |
| | |||
| Hard Drives NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. |
|||
| SAS Hot Plug SFF Enterprise (ENT) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 300GB 3G SAS 10K DP 300GB 6G SAS 10K DP 146GB 6G SAS 10K DP 146GB 6G SAS 15K DP 146GB 3G SAS 15K DP 146GB 3G SAS 10K DP 72GB 6G SAS 15K DP 72GB 3G SAS 10K DP 72GB 3G SAS 15K DP |
Up to 8
|
1-8
|
HP Smart Array P800/512 BBWC
Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| NOTE: Second SFF drive cage requires second controller or HP SAS Expander Card (PN 468406-B21). | |||
| SAS Hot Plug 3.5" Enterprise (ENT) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 600GB 6G SAS 15K DP 450GB 6G SAS 15K DP 450GB 3G SAS 15K DP 300GB 6G SAS 15K DP 300GB 3G SAS 15K DP 146GB 3G SAS 15K DP |
Up to 6
|
1-6
|
HP Smart Array P800/512 BBWC
Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| SAS Hot Plug SFF Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 500GB 6G SAS 7.2K DP |
Up to 8
|
1-8
|
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| SAS Hot Plug 3.5" Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 1TB 3G SAS 7.2K DP 750GB 3G SAS 7.2K DP |
Up to 6
|
1-6
|
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| SATA Hot Plug SFF Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 500GB 3G SATA 7.2K 160GB 3G SATA 7.2K |
Up to 8
|
1-8
|
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| SATA Hot Plug 3.5" Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 1TB 3G SATA 7.2K 750GB 3G SATA 7.2K 500GB 3G SATA 7.2K 250GB 3G SATA 7.2K |
Up to 6
|
1-6
|
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| SATA Hot Plug 3.5" Entry (ETY) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 160GB 3G SATA 7.2K |
Up to 6
|
1-6
|
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| SATA Hot Plug SFF Entry (ETY) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 250GB 3G SATA 5.4K 120GB 1.5G SATA 5.4K |
Up to 8
|
1-8
|
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| NOTE: Second SFF drive cage requires second controller or HP SAS Expander Card (PN 468406-B21). | |||
| SATA Hot Plug Midline (MDL) Solid State Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 60GB 3.0G SATA SSD 120GB 3.0G SATA SSD |
Up to 8
|
1-8
|
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| SATA Hot Plug 3.5" Midline (MDL) Solid State Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 60GB 3.0G
SATA SSD 120GB 3.0G SATA SSD |
Up to 6
|
1-6
|
HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
|
External Storage |
|||
|
Quantity |
Position |
Host Controller or Adapter |
|
| 50 Modular Smart Array |
Up to 4
|
External
|
HP Smart Array P800/512 BBWC Controller |
| 60 Modular Smart Array |
Up to 4
|
External
|
HP Smart Array P212/Zero Memory
Controller HP Smart Array P212/ 256 MB Controller |
|
Up to 8
|
External | HP Smart Array P800/512 BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
| 70 Modular Smart Array |
Up to 2
|
External
|
HP Smart Array P212/Zero Memory
Controller HP Smart Array P212/ 256 MB Controller |
|
Up to 4
|
External | HP Smart Array P800/512 BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
| D2600 Disk Enclosure |
Up to 4
|
External
|
HP Smart Array P212/ 256 MB Controller |
|
Up to 8
|
External | HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
| D2700 Disk Enclosure |
Up to 2
|
External
|
HP Smart Array P212/ 256 MB Controller |
|
Up to 4
|
External | HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
| HP 2000sa Modular Smart Array Controller | Up to 4 | External | HP SC08Ge Host Bus Adapter |
|
|
|||
|
Maximum Storage Capacity - (with MSA50, SAS HDD) |
|
|
Internal |
8.0TB (16 x 500GB SAS SFF with addition 8 SFF drive cage) |
| External | 5.0TB (20 x 250GB SAS SFF) |
| Total | 13.0TB |
|
|
|
|
Maximum Storage Capacity - (with MSA50, SATA HDD) |
|
|
Internal |
4.0TB (16 x 250GB SAS SFF with additional 8 SFF drive cage) |
| External | 5.0TB (20 x 250GB SAS SFF) |
| Total | 9.0TB |
|
|
|
| Tape and Disk-Based Backup | |||
|
NOTE: For a complete listing of compatible tape and disk-based backup offerings, please visit: www.hp.com/go/connect. |
|
Position
Supported |
Controller
|
Part Number |
|
| HP StorageWorks SCSI Tape Drives,
External LTO-1 Ultrium 232 LTO-2 Ultrium 448 LTO-3 Ultrium 960 LTO-3 Ultrium 920 LTO-4 Ultrium 1760 LTO-4 Ultrium 1840 DAT 40 DAT 72 DAT 160 1U Rack-Mount Kit 3U Rack-Mount Kit |
External
|
HP SC11Xe Host Bus Adapter |
412911-B21
|
| HP StorageWorks USB Tape Drives,
External DAT 40 USB DAT 72 USB DAT 160 USB DAT 320 USB 1U Rack-Mount Kit |
External
|
USB 2.0 Port |
N/A
|
| HP StorageWorks SAS Tape Drives,
External DAT 160 SAS DAT 320 USB LTO-2 Ultrium 448 SAS LTO-3 Ultrium 920 SAS LTO-4 Ultrium 1760 SAS LTO-4 Ultrium 1840 SAS 1U Rack-Mount Kit 3U Rack-Mount Kit |
External
|
HP Smart Array P212/Zero Memory Controller |
462828-B21
|
| HP StorageWorks SCSI Tape Automation,
External DAT 72x10 Autoloader 1/8 G2 Autoloader MSL2024 MSL4048 MSL8096 MSL6000 |
External
|
HP SC11Xe Host Bus Adapter |
412911-B21
|
| HP StorageWorks SAS
Tape Automation, External 1/8 G2 Autoloader MSL2024 MSL4048 MSL8096 |
External
|
HP Smart Array P212/Zero Memory Controller |
462828-B21
|
| NOTE: Please visit: http://www.hp.com/go/connect for details about minimum SAS controller firmware version and SAS cabling requirements. | |||
| HP StorageWorks Fibre Tape Automation,
External MSL2024 MSL4048 MSL8096 MSL6000 |
External
|
Please consult the EBS connectivity matrix at: http://www.hp.com/go/ebs for detailed connectivity information. |
N/A
|
| HP StorageWorks RDX Removable
Disk Backup System RDX160 RDX320 RDX500 |
Internal | USB 2.0 NOTE: RDX160 (AP724A), RDX320 (AP725A), or RDX500 (AP726A) are required for mounting inside a HP ProLiant DL380 G6. |
N/A |
| HP StorageWorks D2D Backup Systems D2D2500i D2D4000i |
External
|
Embedded Network Controller |
N/A
|
|
|
Power Specifications
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| NOTES: To review typical system power ratings use the HP Power Advisor which is available online located at url: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor |
|
|
Technical Specifications
| System Unit | Dimensions (H
x W x D) (with bezel) | SFF
Drives: 3.38 x 17.54 x 27.25 in (8.59 x 44.55 x 69.22 cm) LFF Drives: 3.38 x 17.54 x 29.25 in (8.59 x 44.55 x 74.30 cm) | ||
| Weight (approximate) | Maximum (all hard drives, power supply, and processor installed) | 60.00 lb (27.27 kg) | ||
| Minimum
(one hard drive, power supply, and processor installed) | 47.18 lb (21.45 kg) | |||
|
Input Requirements (per power supply) | Rated Line Voltage | 100
to 120 VAC 200 to 240 VAC | ||
| Rated Input Current | For
1200 W Power Supply: 10 A (at 100 VAC), 4.9 A (at 200 VAC) For 750 W Power Supply: 8.9 A (at 100 VAC), 4.3 A (at 200 VAC) For 460 W Power Supply: 5.5 A (at 100 VAC), 2.6 A (at 200 VAC) | |||
| Rated Input Frequency | 50 to 60 Hz | |||
| Rated Input Power | For 1200 W Power
Supply: 930 W (at 100 VAC), 1348 W (at 200 VAC) For 750 W Power Supply: 857 W (at 100 VAC), 824 W (at 200 VAC) For 460 W Power Supply: 526 W (at 100 VAC), 505 W (at 200 VAC) | |||
| BTU Rating | Maximum | For
1200 W Power Supply: 3530 BTU/hr (at 100 VAC), 4600 BTU/hr (at 200 VAC) For 750 W Power Supply: 2925 BTU/hr (at 100 VAC), 2812 BTU/hr (at 200 VAC) For 460 W Power Supply: 1794 BTU/hr (at 100 VAC), 1725 BTU/hr (at 200 VAC) | ||
| Power Specifications | NOTE: To review typical system power ratings use the HP Power Advisor which is available online located at url: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor | |||
| Power Supply Output (per power supply) | Rated Steady-State
Power | For 1200
W Power Supply: 800 W (at 100 VAC), 900 W (at 120 VAC), 1200 W (at 200 to 240 VAC) For 750 W Power Supply: 750 W (at 100 to 120 VAC), 750 W (at 200 to 240 VAC) For 460 W Power Supply: 460 W (at 100 to 120 VAC), 460 W (at 200 to 240 VAC) | ||
| Maximum Peak Power | For 1200
W Power Supply: 800 W (at 100 VAC), 900 W (at 120 VAC), 1200 W (at 200 to 240 VAC) For 750 W Power Supply: 750 W (at 100 to 120 VAC), 750 W (at 200 to 240 VAC) For 460 W Power Supply: 460 W (at 100 to 120 VAC), 460 W (at 200 to 240 VAC) | |||
| System Inlet Temperature | Operating | 10°
to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C
per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of
3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the type and number of options
installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). | ||
| Non-operating | -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). | |||
| Relative Humidity (non-condensing) | Operating | 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. | ||
| Non-operating | 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. | |||
| Altitude | Operating | 3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | ||
| Non-operating | 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | |||
| Acoustic Noise | Listed
are the declared A-Weighted sound power levels (LWAd) and declared average bystander
position A-Weighted sound pressure levels (LpAm) when the product is operating
in a 23°C ambient environment. Noise emissions were measured in accordance
with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). NOTE: The Listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels. | |||
| Idle | 1P SKU | 2P SKU | ||
| LWAd | 4.1
B | 4.7 B | ||
|
LpAm | 22
dBA | 28 dBA | ||
| Operating | 1P
SKU | 2P SKU | ||
| LWAd | 4.1
B | 4.7 B | ||
|
LpAm | 22 dBA | 28 dBA | ||
| Emissions Classification (EMC) | FCC Rating | Class A | ||
| Normative Standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 | |||
| NOTE:
Product conformance to cited product specifications is based on sample (type)
testing, evaluation, or assessment. This product or family of products is eligible
to bear the appropriate compliance logos and statements. NOTE: The Listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels. | ||||
|
| ||||
|
Smart Array P410i Controller |
Dimensions (not including bracket) | Low Profile PCIe Form Factor 7.5 in x 9.5 in x 2.25 in (19.05 cm x 24.13 cm x 5.72 cm) |
| Disk Drive and Enclosure Interface - transfer rate | 6Gb/s SAS (Serial Attached SCSI) | |
| 3Gb/s SATA (Serial ATA) | ||
| SAS Connectors | 2 internal (Mini-SAS) x8 wide port connectors | |
| Cache Memory Speed | DDR2-533MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s maximum bandwidth. | |
| Server Interface | x8 2.5G PCIe 2.0 provides 2GB/s maximum bandwidth | |
| SAS Speed | x8 3G SAS provides 2.4GB/s maximum bandwidth | |
| Cache Memory | 40-bit 256MB ECC protected cache (72-bit 512MB BBWC module upgrades available); transportable with battery-backed upgrade | |
| Logical Drives Supported | Up to 64 logical drives | |
| Maximum Logical Drive Capacity | Greater than 2TB | |
| Host Memory Addressing | 64-bit, supporting greater than 4GB server memory space | |
| RAID Support |
RAID 6, 6+0 (Advanced Data Guarding)
|
|
| RAID 5, 5+0 (Distributed Data
Guarding) NOTE: The 256 MB is required to enable RAID 5, 5+0 support of the Smart Array P410i |
||
| RAID 1+0 (Striping & Mirroring) | ||
| RAID 0 (Striping) | ||
| Upgradeable Firmware | Upgradeable Firmware with Recovery ROM feature | |
|
|
||
| HP NC382i Dual Port Multifunction Gigabit Server Adapters | Network Interface | 10Base-T/100Base-TX/1000Base-TX | |
| Compatibility | EEE 802.3 10Base-T | ||
| IEEE 802.3ab 1000Base-T | |||
| IEEE 802.3u 100Base-TX | |||
| IEEE 802.3ad 1000Base-TX | |||
| IEEE 802.1p 100Base-TX | |||
| IEEE 802.1q 100Base-TX | |||
| Data Transfer Method | PCI Express, four lanes (x4) | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000Mb/s | ||
| Connector | Two RJ-45 | ||
| Cable Support | 10Base-T | Categories
3, 4 or 5 UTP; up to 328 ft (100 m) | |
| 100Base-TX | Category
5 or higher UTP; up to 328 ft (100 m) | ||
| 1000BaseTX | Category
5 or higher UTP; up to 328 ft (100 m) | ||
|
| |||
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go
to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will
be recycled, recovered or disposed of in a responsible manner. |
| | ||
|
© Copyright 2009 Hewlett-Packard Development Company,
L.P. |