|
|
Overview
|
HP ProLiant BL490c Generation 6 (G6) Server Blade |
|||
|
|
|||
| HP ProLiant BL490c G6 Server Blade | |||
|
1.
|
Access Panel | 6. | Two (2) SATA Solid State Drive (SSD) bays |
| 2. | Internal USB connector | 7. | Up to two (2) Intel® Xeon® 5600 or 5500 series processors |
| 3. | Internal SD card slot | 8. | Local I/O connector |
| 4. | Two (2) mezzanine I/O expansion slots | 9. | Eighteen (18) DDR3 Registered or Unbuffered DIMM Memory Slots |
| 5. | Embedded Dual Port Flex-10 10GbE Multifunction Server Adapter | ||
|
|
|||
| What's New |
|
|
|
|
At A Glance |
|
The HP ProLiant BL490c Virtualization Blade raises the bar for memory
capacity and I/O bandwidth in a half-height blade. Coupling up to 2 Intel®
Xeon® processors with 18 DIMM slots and support for up to 24 NICs,
the BL490c gives enterprise data center managers the ideal server platform
for hosting virtual machines.
|
|
|
Standard Features
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | |
| Processor | Intel® Xeon® Processor X5670 (2.93 GHz, 12MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/2/2/3/3) |
| Intel® Xeon® Processor X5650 (2.66 GHz, 12MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/2/2/3/3) | |
| Intel® Xeon® Processor X5570 (2.93 GHz, 8M L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | |
| Intel® Xeon® Processor E5540 (2.53 GHz, 8M L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor L5530 (2.40 GHz, 8MB L3 cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4M L3 Cache, 80W, DDR3-800) | |
| NOTE: HT indicates
that the processor model supports Intel® Hyper-Threading Technology.
NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active (on 5500 series processors), or with 6,5,4,3,2,1 cores active (on 5600 series processors). NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: For the Intel 5500 and 5600 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. |
|
|
|
|
| Upgradeability | Upgradeable to two (2) processors |
|
|
|
| Cache Memory | 4MB shared L3 cache |
| 8MB shared L3 cache | |
| 12MB shared L3 cache | |
|
|
|
| Chipset | Intel® 5500 Chipset |
|
|
|
| Memory | Type | DDR3 Registered (RDIMM) or Unbuffered (UDIMM) |
| Standard | 6 GB (3 x 2GB) RDIMM | |
| Maximum (RDIMM) | 192 GB (12 x 16 GB) for Registered Memory configurations | |
| Maximum (UDIMM) | 48 GB (12 x 4 GB) for Unbuffered Memory configurations | |
| NOTE: Depending on the memory configuration and processor model the memory speed may run at 1333MHz, 1066MHz or 800MHz. Please see the Online Memory Configuration Tool for details; www.hp.com/go/ddr3memory-configurator | ||
DDR3
memory options part number decoder |
||
|
|
||
| Network Controller | Embedded NC532i Dual Port Flex-10
10GbE Multifunction Server Adapter NOTE: Flex-10 capability requires the use of an HP Virtual Connect Flex-10 10Gb Ethernet module. Learn more at: www.hp.com/go/virtualconnect. |
| NOTE: The iSCSI offload feature of the embedded multifunction adapter requires the HP Accelerated iSCSI Pack. For more information, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12466_div/12466_div.html | |
| One (1) additional 10/100 NIC dedicated to iLO 2 Management | |
|
|
|
| I/O Expansion Slots | Two (2) I/O expansion mezzanine slots (x8 PCI Express) |
|
|
|
| Integrated Manageability | HP Integrated Lights-Out 2 (iLO 2) management processor |
|
|
|
| Storage Controller | HP Integrated SATA Controller
NOTE: RAID functionality requires the use of an optional Smart Array mezzanine card. See the Storage Controller options section below. |
|
|
|
| Maximum Internal Storage | Non-Hot Plug SATA SSD | 128GB | 2 x 64GB |
| Hot Plug SFF SAS | 1.8TB | 6 x 300GB | |
| NOTE: Hot Plug SFF SAS maximum internal storage supported with optional SB40c Storage Blade attached. | |||
|
|
|||
| Graphics | Integrated ATI-RN50 with 32MB video memory |
|
|
|
| Graphics Resolution Supported | Resolution Color Depths | 1600 x 1200, 64K, 256, 16 1280 x 1024, 16.7M, 64k, 256, 16 1024 x 768, 16.7M, 64k, 256, 16 800 x 600, 16.7M, 64k, 256, 16 640 x 480, 16.7M, 64k, 256, 16 NOTE: Maximum resolution available via HP Integrated Lights-Out 2 (iLO 2) remote console is 1280 x 1024. |
| | ||
| Fibre Channel Support |
Two (2) optional Fibre Channel HBAs are supported by the HP ProLiant BL490c G6. Both mezzanine circuit boards connect directly to the server blade system board. These Fibre Channel HBAs are available via option kits and must be ordered separately. |
|
HBA mezzanine card option kits:
Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem (PN 456972-B21)
QLogic QMH2462 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem (PN 403619-B21)
QLogic QMH2562 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem (PN 451871-B21)
HP BLc Brocade 804 8Gb Fibre Channel Host Bus Adapter (PN 590647-B21)
Brocade, Emulex and QLogic Fibre Channel HBAs for HP BladeSystem c-Class feature:
|
|
|
|
|
| Compatible SAN |
HP ProLiant BL490c G6 server blades are optimized for HP StorageWorks
MSA, EVA and XP |
|
|
|
| HP Virtual Connect |
HP Virtual Connect simplifies server connectivity to data and storage networks, and reduces costs. Unique HP Flex-10 and FlexFabric technologies make maximum use of network bandwidths, provide dynamic tuning and enable extreme flexibility to meet individual server and infrastructure requirements. HP Virtual Connect Enterprise Manager (VCEM) provides a central console to administer network connections and workloads for thousands of servers. For more information on Virtual Connect Ethernet, Fibre Channel, Converged Network and management options see: www.hp.com/go/virtualconnect |
|
|
|
| HP Insight management software | HP Insight Foundation |
Managing the growing number of servers can be complex and expensive for
your organization. IT managers need to address changing business needs
with tools that meet the challenges of managing today's complex Datacenters.
NOTE: In an effort to support reducing our environmental impact, the HP Insight Foundation Suite for ProLiant media will be available as a selectable option for this server at time of order of a Factory Integrated Model. This will allow customers to order the number of media kits that best meet their needs and eliminate receiving unnecessary duplicate media. |
| HP Integrated Lights-Out 2 |
HP Integrated Lights-Out (iLO) simplifies server setup, health monitoring, power and thermal control, and lights-out remote administration of ProLiant ML, DL, and BL servers. HP iLO functions without additional software and can be accessed from any location via a web browser. HP iLO works hand-in-hand with HP Systems Insight Manager, Insight Control suites, and Insight Dynamics for ProLiant, helping customers unleash the value of the ProLiant platform and deliver the highest possible quality of IT service. For more information, visit: www.hp.com/go/iLO |
|
| HP Insight Control |
HP Insight Control, a product option, delivers essential infrastructure
management that can help save time and money by making it easy to deploy,
migrate, monitor, remote control, and optimize your IT infrastructure
through a single, simple management console. |
|
| HP Insight Dynamics for ProLiant | HP Insight Dynamics for ProLiant, a product
option, is advanced infrastructure management software that enables IT staff
to instantly adjust their environments to meet dynamic business demands
by provisioning, optimizing and protecting complex infrastructure in minutes.
It's a powerful toolkit, integrated-by-design, that accelerates complex
technology projects and simplifies daily operations, transforming data center
economics. With Insight Dynamics IT professionals can plan capacity and
power continuously, balance workloads across physical and virtual resources,
and ensure cost-effective high availability. It also enables IT organizations
to provision infrastructure consistently and automatically from pools of
shared resources using a self-service portal. Resources provisioned can
range from a single virtual machine to complex multi-tier environments and
their associated physical and virtual resource requirements. In addition
to the previous functional benefits, it also provides a cost-effective disaster
recovery for physical and virtual environments that works with HP StorageWorks
Continuous Access software for both the Enterprise Virtual Array and the
XP storage array allowing application environments to be reactivated in
minutes with the touch of a button to a remote location. NOTE: For more information, visit: http://www.hp.com/go/insightdynamics |
|
|
|
||
| High Performance Clusters | HP Cluster Platforms |
HP Cluster Platforms are specifically engineered, factory-integrated large-scale ProLiant clusters optimized for High Performance Computing, with a choice of servers, networks and software. Operating system options include specially priced offerings for Red Hat Enterprise Linux and Novell SLES, as well as Microsoft Windows HPC Server. A Cluster Platform Configurator simplifies ordering. http://www.hp.com/go/clusters |
| HP HPC Interconnects |
High Performance Computing (HPC) interconnect technologies are available for this server as part of the HP Cluster Platform portfolio. These high-speed InfiniBand and Gigabit interconnects are fully supported by HP when integrated within an HP cluster. Flexible, validated solutions can be defined with the help of configuration tools. http://www.hp.com/techservers/clusters/ucp/index.html |
|
| HP Cluster Management Utility |
HP Cluster Management Utility (CMU) is an HP-licensed and HP-supported suite of tools that are used to manage large-scale Linux ProLiant systems. CMU includes software for the centralized provisioning, management and monitoring of nodes. CMU makes the administration of clusters user friendly, efficient, and effective. http://www.hp.com/go/cmu |
|
| HP HPC Linux Value Pack | HP HPC Linux Value Pack (Value Pack) is an HP-licensed and HP-supported specially priced software bundle for the development and deployment of applications on HPC Cluster Platforms. Value Pack includes the Platform LSF workload scheduler, the HP-MPI parallelization library, the HP Unified Parallel C compiler and the HP Shmem library, as well as the execution environments for the libraries and compiler. HP HPC Linux Value Pack | |
|
|
||
|
Operating Systems and Virtualization Software Support for ProLiant Servers |
Microsoft
Windows Server |
| NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/ossupport and our driver download page http://www.hp.com/support/BL490cG6 | |
|
|
|
| Availability |
|
|
|
|
| Industry Standard Compliance |
ACPI V2.0 Compliant |
|
|
|
| Security |
|
|
| |
| Security - Trusted Platform Module | The TPM (Trusted Platform Module)
is a microcontroller chip that can securely store artifacts used to authenticate
the server platform. These artifacts can include passwords, certificates
and encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker)
is a data protection feature available in Windows Server® 2008. BitLocker
leverages the enhanced security capabilities of a Trusted Platform Module
(TPM) version 1.2. The TPM works with BitLocker to help protect user data
and to ensure that a server running Windows Server 2008 has not been tampered
with while the system was offline. NOTE: For more information about TPM, including a white paper, go to: http://www.hp.com/go/TPM NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment. NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing the key could result in data loss. |
|
| |
| Factory Express Portfolio for Servers and Storage | HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services on your specific server model please contact your sales representative or go to: http://www.hp.com/go/factory-express. |
|
|
|
| HP Enterprise Configurator | The HP eConfigure Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. For additional information please visit: http://www.hp.com/products/configurator |
| | |
| Service and Support |
HP Care Pack services provide total care and support expertise with committed
response designed to meet your IT and business needs.
Enhanced Service - Optimize service level to increase IT performance and availability
Installation & Start-Up service for HP BladeSystem Infrastructure
plus HP BladeSystem Enhanced Network Installation and Start-UP as per
the Customer Description and/or Data Sheet. To be delivered on a scheduled
basis 8am-5pm, M-F, excluding HP holidays. |
|
|
Models
| Models | ||
|
HP ProLiant BL490c G6 X5650 2.66GHz (1P) | Processor(s) One of the following depending on model |
One (1) Intel ® Xeon® Processor X5650 (2.66 GHz, 12MB L3 Cache,
95W, DDR3-1333, HT, Turbo 2/2/2/2/3/3) |
| Cache Memory One of the following depending on model |
4MB Shared L3 Cache 8MB Shared L3 Cache 12MB Shared L3 Cache |
|
| Memory | 6 GB (3 x 2 GB) PC3-10600 (DDR3-1333) Registered DIMMs | |
| Network Adapter | Embedded NC532i Dual Port Flex-10 10GbE Multifunction Server Adapter and one (1) additional 10/100 server adapter dedicated to iLO 2 management | |
| Storage Controller | HP Integrated SATA Controller | |
| Hard Drives | No drives included | |
| Internal Storage | SSD: Up to 128GB (2 x 64GB) SATA | |
| Optical Drive | None | |
| Power Supply | None | |
| Form Factor | Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure Up to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure |
|
|
|
Configuration Information - Factory Integrated Models
| NOTE:
This section lists some of the steps required to configure a Factory Integrated
Model. To ensure only valid configurations are ordered, HP recommends the
use of an HP approved configurator. Contact your local sales representative
for information on CTO product offerings and requirements. NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order server blades must start with a CTO Blade. NOTE: FIO indicates that this option is a Factory Installable Option. |
||
| Step 1: Base Server Blade Configuration (Select a configurable Blade) | ||
| Models | HP ProLiant BL490c G6 Configure-to-order Server |
498357-B21
|
| Configurable Model ships with: | ||
| Embedded NC532i Dual Port Flex-10 10GbE Multifunction Server Adapter and one (1) additional 10/100 server adapter dedicated to iLO 2 management | ||
| Integrated Lights-Out 2 Standard Blade Edition | ||
|
| ||
| Step 2: Choose Required Options (one of the following from each list unless otherwise noted) | ||
| HP Processors | For single processor configuration choose: | |
| Six-Core Processor Option Kits | ||
| HP BL490c G6 Intel®
Xeon® X5670 (2.93GHz/6-core/95W/12MB) FIO Processor Kit NOTE: If two processors are desired, select one 595826-L21 and one 595826-B21. |
595826-L21 | |
| HP BL490c G6 Intel®
Xeon® X5650 (2.66GHz/6-core/95W/12MB) FIO Processor Kit NOTE: If two processors are desired, select one 595827-L21 and one 595827-B21. |
595827-L21 | |
| Quad-Core Processor Option Kits | ||
| Intel® Xeon®
X5570 2.93GHz Quad Core 95 Watts BL490c G6 Factory Integrated Processor
Option Kit NOTE: If two processors are desired, select one 509319-L21 and one 509319-B21. |
509319-L21 | |
| Intel® Xeon®
E5540 2.53GHz Quad Core 80 Watts BL490c G6 Factory Integrated Processor
Option Kit NOTE: If two processors are desired, select one 509322-L21 and one 509322-B21. |
509322-L21
|
|
| Intel® Xeon®
L5530 2.40GHz Quad Core 60 Watts BL490c G6 Factory Integrated Processor
Option Kit NOTE: If two processors are desired, select one 576216-L21 and one 576216-B21. |
576216-L21 | |
| Intel® Xeon®
E5504 2.0GHz Quad Core 80 Watts BL490c G6 Factory Integrated Processor Option
Kit NOTE: If two processors are desired, select one 509327-L21 and one 509327-B21. |
509327-L21 | |
| HP Memory | Registered DIMMS (RDIMMs) | |
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit |
500656-B21
|
|
| HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit |
500658-B21
|
|
| HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low Power Memory Kit | 500660-B21 | |
| HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 593339-B21 | |
| HP 4GB (1x4GB) Single
Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit NOTE: Low Voltage DIMMs can only be used with Intel Xeon 5600 series processors. |
604504-B21 | |
| HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 500662-B21 | |
| HP 8GB (1x8GB) Dual Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit | 516423-B21 | |
| HP 8GB (1x8GB) Dual
Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit NOTE: Low Voltage DIMMs can only be used with Intel Xeon 5600 series processors. |
604506-B21 | |
| HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit | 500666-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500668-B21 | |
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500670-B21 | |
| HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500672-B21 | |
| NOTE:
All DDR3 memory option kits consist of one DIMM per kit. For detailed memory
configuration rules and guidelines, please use the Online DDR3 Memory Configuration
Tool: www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient. NOTE: PC3L is a low voltage memory. |
||
|
|
||
| Step 3: Choose Additional Options for Factory Integration |
| NOTE:
For additional options, please refer to the "Core Options" and
"Additional Options" section below. For additional options, including
server blade enclosures interconnect and mezzanine options and power subsystem
options; please see the Core Options and Additional Options sections below;
or the following: HP BladeSystem c3000 Enclosure QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/12790_div/12790_div.html HP BladeSystem c7000 Enclosure QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/12810_div/12810_div.html and HP BladeSystem c-Class Interconnect and Mezzanine Components: http://h18004.www1.hp.com/products/blades/components/c-class-interconnects.html http://h18004.www1.hp.com/products/blades/components/c-class-adapters.html |
|
|
Core Options
| NOTE: Some options may not be available for factory integration. Please contact an HP sales representative for additional information. | ||
| HP Ethernet Mezzanine Options | Gigabit Ethernet Mezzanines | |
| HP NC325m PCI Express Quad Port
Gigabit Server Adapter NOTE: If the NC325m is installed in mezzanine slot 1 of a half-height server, connectivity will be provided on 2 of the 4 ports. |
416585-B21
|
|
| HP NC326m PCI Express Dual Port 1Gb Server Adapter |
406771-B21
|
|
| HP NC360m Dual Port 1GbE BL-c Adapter | 445978-B21 | |
| HP NC364m Quad Port 1GbE BL-c
Adapter NOTE: If the NC364m is installed in mezzanine slot 1 of a half-height server, connectivity will be provided on only 2 of the 4 ports. |
447883-B21
|
|
| HP NC382m PCI Express Dual Port Multifunction Gigabit Server Adapter |
453246-B21
|
|
| QLogic iSCSI Dual Port Adapter with Virtual Connect for c-Class BladeSystem | 488074-B22 | |
| NOTE: The Gigabit Ethernet adapters above transmit from the server at 2000 Mbps, full duplex per port only. For more information, see the "Network Controller" segment in the Standards Features section. | ||
| 10 Gigabit Ethernet Mezzanines | ||
| NOTE: A 10 Gigabit
Ethernet adapter is required for each server blade connecting to a 10Gb
interconnect in bays 3-8 (HP BladeSystem c7000 Enclosure) or bays 2-4 (HP
BladeSystem c3000 Enclosure). NOTE: Each 10 Gigabit Ethernet adapter requires a minimum of 2GB of server memory. NOTE: Each 10 Gigabit Either adapter supports linking at 1000Mbps or 10000Mbps when not connected to a Flex-10 enabled module and will link with all current 1Gb switches at 1Gb. NOTE: The ROM Based Setup Utility (RBSU) feature allows for the configuring of a FlexFabric Adapter to any of the supported protocols. For example iSCSI to FCoE (Fibre Channel over Ethernet). Note that a HP Virtual Connect profile takes precedence over the setting in this menu. Also, some FlexFabric Adapters may require that network boot be enabled in order to configure the protocol. If the protocol is configured without enabling network boot with certain FlexFabric Adapters, the protocol may not take effect. Once the protocol has taken effect on the first boot after configuring this option, network boot may be disabled if desired. |
||
| HP NC522m Dual Port 10GbE Multifunction BL-c Adapter | 467801-B21 | |
| HP NC532m Dual Port 10GbE BL-c Adapter |
467799-B21
|
|
| HP NC542m Dual Port Flex-10 10GbE Multifunction BL-c Adapter | 539857-B21 | |
| HP NC550m 10GbE 2-port PCIe x8 Flex-10 Ethernet Adapter | 581204-B21 | |
| HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter | 580151-B21 | |
| HP BLc NC552m Flex-10GbE Dual Port Adapter | 610609-B21 | |
| HP NC553m 10Gb 2-port FlexFabric Adapter | 613431-B21 | |
|
|
||
| HP Fiber Channel Mezzanine Options | Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem |
456972-B21
|
| Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem | 403621-B21 | |
| QLogic QMH2562 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem | 451871-B21 | |
| QLogic QMH2462 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem | 403619-B21 | |
| HP BLc Brocade 804 8Gb Fibre Channel Host Bus Adapter | 590647-B21 | |
|
|
||
| HP Processors | Six-Core Processors | |
| HP BL490c G6 Intel® Xeon® X5670 (2.93GHz/6-core/95W/12MB) Processor Kit | 595826-B21 | |
| HP BL490c G6 Intel® Xeon® X5650 (2.66GHz/6-core/95W/12MB) Processor Kit | 595827-B21 | |
| Quad-Core Processors | ||
| HP BL490c G6 Intel® Xeon® X5570 (2.93GHz/4-core/8MB/95W) Processor Kit | 509319-B21 | |
| HP BL490c G6 Intel® Xeon® E5540 (2.53GHz/4-core/8MB/80W) Processor Kit |
509322-B21
|
|
| HP BL490c G6 Intel® Xeon® L5530 (2.40GHz/4-core/8MB/60W) Processor Kit | 576216-B21 | |
| HP BL490c G6 Intel® Xeon® E5504 (2.00GHz/4-core/4MB/80W) Processor Kit | 509327-B21 | |
|
|
||
| HP Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit |
500656-B21
|
|
| HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit |
500658-B21
|
|
| HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low Power Memory Kit | 500660-B21 | |
| HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 593339-B21 | |
| HP 4GB (1x4GB) Single Rank x4
PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit NOTE: Low Voltage DIMMs can only be used with Intel Xeon 5600 series processors. |
604504-B21 | |
| HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 500662-B21 | |
| HP 8GB (1x8GB) Dual Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit | 516423-B21 | |
| HP 8GB (1x8GB) Dual Rank x4 PC3L-10600
(DDR3-1333) Registered CAS-9 Low Power Memory Kit NOTE: Low Voltage DIMMs can only be used with Intel Xeon 5600 series processors. |
604506-B21 | |
| HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit | 500666-B21 | |
| Unbuffered with ECC (UDIMMs) | ||
| HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500668-B21 | |
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500670-B21 | |
| HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500672-B21 | |
| NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator. | ||
| NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/ | ||
| NOTE: PC3L is a low voltage memory. | ||
|
|
||
| HP Hard Drives | NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. | |
| Solid State Drives (SSD) | ||
| HP 32GB 1.5G SATA SFF (2.5-inch) Non-hot Plug Entry 3yr Warranty Solid State Drive |
461201-B21
|
|
| HP 64GB 1.5G SATA SFF (2.5-inch) Non-hot Plug Entry 3yr Warranty Solid State Drive |
461203-B21
|
|
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13121_div/13121_div.html |
|
|
Additional Options
| HP Insight software | HP Insight Control | |
| HP Insight Control including 1yr 24x7 Technical Support and Updates Electronic License |
T9074BAE
|
|
| HP Insight Control including 1yr 24x7 Technical Support and Updates Single Server License |
452148-B22
|
|
| HP Insight Software Media Kit NOTE: Insight Software DVD media without licenses. Contains Insight Control, Insight Dynamics and Virtual Connect Enterprise Manager. Uses an integrated installer to perform quick and accurate software installation and updates. |
436222-B21 | |
| NOTE: Licenses
ship without media. The HP Insight Control Media Kit can be ordered separately,
or can be downloaded at: http://www.hp.com/go/insightupdates.
NOTE: Electronic licenses can be used to purchase multiple licenses with a single activation key, and is available in all countries except China and Japan. Customers in China and Japan should order the physical equivalent. NOTE: Customer will receive a license entitlement certificate, which must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support & Update Service. NOTE: For additional license kits, including bundles with HP BladeSystem enclosures, please see the Insight Control QuickSpecs at: http://h18004.www1.hp.com/products/quickspecs/12631_div/12631_div.html |
||
| HP Insight Control for Linux | ||
| HP Insight Control for Linux including 1yr 24x7 Support Electronic License | TC213AAE | |
| HP Insight Control for Linux including 1yr 24x7 Support Single Server License | TC209A | |
| HP Insight Control for Linux Media Kit | TC208A | |
| NOTE: Licenses
ship without media. The Media Kit for Insight Control for Linux can be ordered
separately, or can be downloaded at: http://www.hp.com/go/ic-linux
(click on Download button). NOTE: Electronic licenses can be used to purchase multiple licenses with a single activation key, and are available in all countries except China and Japan. Customers in China and Japan should order the physical equivalent. NOTE: Customer will receive a license entitlement certificate, which must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. NOTE: For additional License Kits, including electronic licensing options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_div/13019_div.html |
||
| HP Integrated Lights-Out (iLO) Advanced for BladeSystem | ||
| HP iLO Advanced for BladeSystem including 1yr 24x7 Support Electronic License | TA851AAE | |
|
HP iLO Advanced for BladeSystem including 1yr 24x7 Support Single Server License |
512488-B21 | |
|
NOTE: Electronic licenses can be used to purchase multiple licenses
with a single activation key, and is available in all countries except
China and Japan. Customers in China and Japan should order the physical
equivalent. |
||
| HP Insight Control server deployment | ||
| HP Insight Control Server Deployment including 1yr 24x7 Support Electronic License | T9082AAE | |
| HP Insight Control Server Deployment including 1yr 24x7 Support Single Server License | 452151-B21 | |
| NOTE: Licenses
ship without media. The Insight Control Media Kit can be ordered separately,
or can be downloaded at: http://www.hp.com/go/insightupdates.
NOTE: Electronic licenses can be used to purchase multiple licenses with a single activation key, and is available in all countries except China and Japan. Customers in China and Japan should order the physical equivalent. NOTE: Customer will receive a license entitlement certificate, which must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. NOTE: For additional license kits please see the Insight Control QuickSpecs at: http://h18004.www1.hp.com/products/quickspecs/12631_div/12631_div.html |
||
|
|
||
| High Performance Clusters | HP Cluster Management Utility
Compute Node License NOTE: This part number can be used to purchase one certificate for multiple licenses with a single activation key. Each license is for one node (server). Customer will receive a printed end user license agreement and license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online in order to obtain a license key. NOTE: For additional license kits please see the QuickSpecs at: http://h18004.www1.hp.com/products/quickspecs/12612_div/12612_div.html |
436284-B21
|
| HP Cluster Management Utility
Media and Management License NOTE: Order a minimum of one license per cluster to purchase media including software and documentation, which will be delivered to the customer, and also licenses CMU management. No license key is delivered or required. NOTE: For additional license kits please see the QuickSpecs at: http://h18004.www1.hp.com/products/quickspecs/12612_div/12612_div.html |
433257-B21 | |
| HP HPC Linux Value Pack One Processor
License NOTE: This part number can be used to purchase one certificate for multiple licenses with a single activation key. Each license is for one socket (a.k.a. processor). Customer will receive a printed end user license agreement and license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online in order to obtain a license key. NOTE: For additional license kits please see the QuickSpecs at: http://h18004.www1.hp.com/products/quickspecs/13485_div/13485_div.html |
TC293A | |
| HP HPC Linux Value Pack Media NOTE: This part number can be used to purchase media including software and documentation, which will be delivered to the customer. NOTE: For additional license kits please see the QuickSpecs at: http://h18004.www1.hp.com/products/quickspecs/13485_div/13485_div.html |
TC294A | |
|
|
||
| HP Security - TPM | HP Trusted Platform Module Option |
488069-B21
|
|
|
||
| HP Storage Controller | HP Smart Array P700m Controller | |
| HP Smart Array P700m/512 4-ports Ext PCIe x8 SAS Controller |
508226-B21
|
|
| HP Smart Array P700m/256 4-ports Ext PCIe x8 SAS Controller | 507925-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional configuration
information at: http://h18000.www1.hp.com/products/quickspecs/13175_div/13175_div.html (Worldwide) |
||
| HP Smart Array P712m Controller | ||
| HP Smart Array P712m/ZM 2-ports Int PCIe x8 SAS Controller | 484299-B21 | |
| NOTE: Provides RAID support on internal non-hot plug SSDs. | ||
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional configuration
information at: http://h18000.www1.hp.com/products/quickspecs/13296div/13296_div.html (Worldwide) |
||
| Optional Upgrades | ||
| HP Smart Array P-Series Low Profile
Battery NOTE: Supports HP Smart Array P700m Controller. |
452348-B21 | |
| HP 650 mAh P-series Low Profile
Battery NOTE: Supports HP Smart Array P712m Controller. |
575031-B21 | |
| HP 256MB P-series Cache Upgrade NOTE: Supports HP Smart Array P712m Controller. |
462968-B21 | |
| HP Smart Array Advanced Pack including
1yr 24x7 Technical Support and Updates Single Server License NOTE: A license key, a minimum of 256MB cache, and battery kit is required to enable Smart Array Advanced Pack features. For more information go to: http://www.hp.com/go/saap NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13201_div/13201_div.html (Worldwide) |
516471-B21 | |
|
|
||
| HP I/O Expansion Options | HP StorageWorks 80GB IO Accelerator for BladeSystem c-Class |
AJ876A
|
| HP StorageWorks 160GB IO Accelerator for BladeSystem c-Class | AJ877A | |
| HP StorageWorks 320GB IO Accelerator for BladeSystem c-Class | AJ878A | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13220_div/13220_div.html | ||
|
|
||
| HP c-Class Mezzanine Options | QLogic 4X QDR IB Mezzanine HCA for HP BladeSystem c-Class |
583210-B21
|
| HP 4X QDR IB CX2 Dual Port Mezz HCA | 592519-B21 | |
| HP 4X DDR InfiniBand Dual Port Mezzanine HCA for c-Class BladeSystem |
448262-B21
|
|
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12586_div/12586_div.html | ||
|
|
||
| HP Ultrium Tape Blades | HP StorageWorks SB1760c Tape Blade NOTE: LTO-4 Ultrium tape technology. |
AQ697A
|
| HP StorageWorks SB920c Tape Blade NOTE: LTO-3 Ultrium technology. |
AJ401A
|
|
| HP StorageWorks Ultrium 448c Tape
Blade NOTE: LTO-2 Ultrium technology. |
440947-B21 | |
| NOTE: The HP PCI
Express Mezzanine Pass-Thru Card for HP BladeSystem (431643-B21) is required
when installing a tape blade adjacent to a full-height server blade. NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12729_div/12729_div.html |
||
|
|
||
| HP StorageWorks Storage Blades | HP StorageWorks LTO-5 SB3000c Tape Blade | BS580A |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12729_div/12729_div.html (Worldwide) |
||
| HP StorageWorks D2200sb PCIe Storage
Blade NOTE: The HP PCI Express Mezzanine Pass-Thru Card (P/N 431643-B21) is required to support the HP StorageWorks D2200sb PCIe Storage Blade with the BL620c G7. Up to two storage blades are supported per server mix and match (Ultrium Tape, D2200sb PCIe Storage, and/or PCI Expansion Blades). NOTE: The HP PCI Express Mezzanine Pass-Thru Card can be placed in mezzanine slot 2 and/or 3. NOTE: Please see the HP StorageWorks D2200sb PCIe Storage Blade QuickSpecs for technical specifications and additional information at: http://h18006.www1.hp.com/storage/bladesystem/index.html. |
AP880A
|
|
|
|
||
| HP Expansion Blade | HP BLc PCI Expansion Blade NOTE: Ships with one pre-installed PCI-X connect board. Also includes one PCIe connect board which requires installation. NOTE: Please see the QuickSpecs for Technical Specifications and additional configuration information: http://h18000.www1.hp.com/products/quickspecs/12753_div/12753_div.html |
448018-B21
|
|
|
||
| HP USB and SD Options | HP USB 2-Button Optical Scroll Mouse | DC172B |
| HP USB Standard Keyboard | DT528A#ABA | |
| HP 2GB USB Flash Media Drive Key NOTE: HP qualified blank USB key for use with HP ProLiant servers that support the VMware virtualization environment and other HP value-add software like SmartStart. HP recommends this industry standard USB flash device for use with VMware ESXi. USB device must be installed in the internal slot of the ProLiant server for use with VMware ESXi. Refer to HP VMware Getting Started Guide for installation instructions. |
608447-B21 | |
| HP 4GB SD Flash Media | 580387-B21 | |
| NOTE: Blank SD media devices are supported for use with VMware and Citrix. SD media must be installed in the internal slot of the ProLiant server. Learn more at: http://www.hp.com/go/proliantvirtualization | ||
|
|
||
| HP Care Pack Services | NOTE: The HP Care Pack service part numbers below for ProLiant BL c-Class server blades, cover the server blade and all HP branded hardware options qualified for the server, purchased at the same time or afterwards, internal to the server. | |
| Hardware Services On-site Service | ||
| 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic |
UK065E
|
|
| 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
UK066E
|
|
| 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
UK067E
|
|
|
Memory
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
| Memory Population Guidelines |
|
For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration
Tool:
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
NOTES:
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HP ProLiant BL490c G6 Server Blade DIMM slot and configuration diagrams | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Basic memory slot & population diagram
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HP ProLiant BL490c G6 Server Blade (1P Model) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Standard memory configuration (1 CPU model)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Standard memory plus optional memory (1 CPU model)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Standard Memory Replaced with Optional Memory (1 CPU model)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
UDIMM maximum configuration (1 CPU model)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Standard Memory Replaced with Optional Memory (2 CPU Model)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
UDIMM maximum configuration (2 CPU model)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
NOTE: Capacity references are rounded to the common Gigabyte values.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Following are memory options available from HP: | ||
| HP Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 500656-B21 | |
| HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 500658-B21 | |
| HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low Power Memory Kit | 500660-B21 | |
| HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 593339-B21 | |
| HP 4GB (1x4GB) Single Rank x4
PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit NOTE: Low Voltage DIMMs can only be used with Intel Xeon 5600 series processors. |
604504-B21 | |
| HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 500662-B21 | |
| HP 8GB (1x8GB) Dual Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit | 516423-B21 | |
| HP 8GB (1x8GB) Dual Rank x4 PC3L-10600
(DDR3-1333) Registered CAS-9 Low Power Memory Kit NOTE: Low Voltage DIMMs can only be used with Intel Xeon 5600 series processors. |
604506-B21 | |
| HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit | 500666-B21 | |
| Unbuffered with ECC (UDIMMs) | ||
| HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500668-B21 | |
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500670-B21 | |
| HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500672-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: PC3L is a low voltage memory. |
||
|
|
Storage
![]() |
1
|
Non Hot Plug Solid State Drive (SSD) Bay 1 |
| 2 | Non Hot Plug Solid State Drive (SSD) Bay 2 |
| Hard Drives | |||
| NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. | |||
| SATA Non-Hot Plug Solid State Drives | |||
|
Quantity Supported
|
Position Supported
|
Controller | |
| 32GB 1.5G SATA SSD |
2
|
1-2
|
HP Integrated SATA Controller HP Smart Array P712m Controller |
| 64GB 1.5G SATA SSD | 2 | 1-2 | HP Integrated SATA Controller HP Smart Array P712m Controller |
|
|
|||
|
External Storage |
|||
|
Quantity |
Position |
Host Controller or Adapter |
|
| XP Disk Array Systems |
Please see the XP Disk Array Systems QuickSpecs below
to determine configuration requirements
|
External
|
Please see the XP Disk Array Systems Quick Specs for the latest list of supported HBAs |
| HP StorageWorks XP10000
Disk Array: http://h18006.www1.hp.com/products/storageworks/xp10000/index.html (Worldwide) |
|||
| Enterprise Virtual Array Systems |
Please see the XP Disk Array Systems QuickSpecs below
to determine configuration requirements
|
External
|
Please see the XP Disk Array Systems Quick Specs for the latest list of supported HBAs |
| HP StorageWorks Enterprise
Virtual Array Family: http://h18006.www1.hp.com/products/quickspecs/12408_div/12408_div.html (Worldwide) |
|||
|
|
Technical Specifications
| System Unit | Dimensions (H x W x D) (with bezel) |
7.154 x 2.19 x 20.058 in (18.17 x 5.56 x 50.95 cm) | |
| Weight (approximate) |
Maximum (all hard drives and processors installed) |
14.20 lb (6.44 kg) | |
| Minimum (one hard drive and processor installed) |
10.75 lb (4.87 kg) | ||
| Power Specifications |
For power specifications including Input Requirements, BTU Rating, and
Power Supply Output, please see the HP BladeSystem c-Class Enclosures
QuickSpecs located at URL: |
||
|
System Inlet Temperature |
Operating |
10° to 35°C (50° to 95°F) at sea level with an altitude
derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above
sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight.
Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may
be limited by the type and number of options installed. |
|
| Non-operating | -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). | ||
| Relative Humidity (non-condensing) |
Operating | 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. | |
| Non-operating | 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. | ||
| Altitude | Operating | 3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | |
| Non-operating | 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | ||
| Acoustic Noise |
For acoustic noise specifications, please see the HP BladeSystem c-Class
Enclosures QuickSpecs located at URL: |
||
|
|
|||
| Embedded NC532i Dual Port Flex-10 10GbE Multifunction Server Adapter | Type | Integrated dual-port KR 10GbE |
| Network Processor | Broadcom 57711 | |
| Data Transfer Method | x4 PCI Express Generation 2 | |
| Network Transfer Rate | Two ports, each at 20 Gbps full
duplex; 40 Gbps aggregate full duplex theoretical bandwidth NOTE: Each port is autosensing 1 Gb / 10 Gb, and can interoperate with 1 Gb HP BladeSystem c-Class interconnect components. NOTE: Each port on the NC532i adapter transmits from the server at only 20 Gbps (theoretical) full duplex. |
|
| IEEE Compliance | 802.1p QoS, 802.1Q VLAN tagging, 802.3ad link aggregation, 802.3ap 10GBase-KR, and 802.3x flow control | |
| Standard Features |
|
|
|
|
||
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go
to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will
be recycled, recovered or disposed of in a responsible manner. |
| | ||
|
© Copyright 2011 Hewlett-Packard Development Company, L.P. |