|
|
Overview
|
HP ProLiant DL370 Generation 6 (G6) | |||
|
HP ProLiant DL370 G6 (Rack) | |||
![]() | ![]() | ||
| Front View: | Rear View: | ||
| 1. | Quick removal access panel | 1. | Mouse connector |
| 2. | Three Hot-plug fans (standard) Five (optional) | 2. | Keyboard connector |
| 3. | Intel Quad-Core Processor (Performance model includes two processors) | 3. | Serial connector |
| 4. | iLO 2 connector | ||
| 4. | Eighteen slots for DDR3 Registered or Unbuffered Memory | 5. | Two USB connectors |
| 5. | SAS/SATA drive cage | 6. | 9 Available PCI-Express Gen2 expansion slots; PCI-X (optional) |
| 6. | Optional drive cage bay | 7. | PCI-X Expansion slot riser bay |
| 7. | Power on/standby button | 8. | Four NIC connectors |
| 8. | System Insight Display | 9. | Video connector |
| 9. | Removal media bay | 10. | Power supply bay 2 |
| 10. | DVD-ROM drive | 11. | Power supply bay 1 (populated) |
| 11. | Optional slimline optical drive bay | ||
| 12. | 9 Available PCI-Express Gen2 slots; PCI-X (optional) | ||
| | |||
| HP ProLiant ML370 G6 (Tower) | |||
![]() |
![]() |
||
| Front View: | Rear View: | ||
| 1. | 9 Available PCI-Express Gen2 slots; PCI-X (optional) | 1. | PCI-X Expansion slot riser bay |
| 2. | Quick removal access panel | 2. | Four NIC connectors |
| 3. | Three Hot-plug fans (standard) Five (optional) | 3. | Video connector |
| 4. | Intel Quad-Core Processor (Performance model includes two processors) | 4. | Power supply bay 2 |
| 5. | Power on/standby button | 5. | Power supply bay 1 (populated) |
| 6. |
Optional drive cage bay |
6. | Mouse connector |
| 7. | SAS/SATA drive cage | 7. | Keyboard connector |
| 8. | System Insight Display | 8. | Serial connector |
| 9. | Optional slimline optical drive bay | 9. | Two USB connectors |
| 10. | DVD-ROM drive | 10. | iLO 2 connector |
| 11. | Removal media bay | 11. | 9 Available PCI-Express Gen2 expansion slots; PCI-X (optional) |
| 12. | Eighteen slots for DDR3 Registered or Unbuffered Memory | ||
|
|
|||
| What's New |
|
Announcing support for:
|
|
|
| At A Glance |
| The next generation
of the HP ProLiant ML370 (expandable tower chassis) and the new HP ProLiant DL370
(4U rack optimized chassis) deliver Industry-leading management tools, leading
performance, expandability, flexibility and the latest energy efficient technologies.
These servers are well-suited for deployment in growing businesses, remote office
sites, or datacenters and have been designed to bring you (our customer) the utmost
confidence to run your business.
|
|
|
Standard Features
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | |
| Processor One of the following depending on Model | Quad-Core Processors |
| Intel® Xeon® Processor W5580 (3.20 GHz, 8MB L3 Cache, 130W, DDR3-1333, HT, Turbo 1/1/1/2) | |
| Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | |
| Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | |
| Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | |
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) | |
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Dual-Core Processors | |
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) | |
| NOTE:
Up to 2 processors supported. Performance configurations include two processors.
Mixing different processor models is not supported. NOTE: HT indicates that the processor model supports Intel® Hyper-Threading Technology. NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active. NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. | |
| | |
| Cache
Memory One of the following depending on Model | 8MB
(1 x 8MB) Level 3 cache NOTE: All processor models except for those identified below. |
| 4MB
(1 x 4MB) Level 3 cache NOTE: For processors E5506/E5504/E5502. | |
| | |
| Upgradeability | Upgradeable to two processors |
| | |
| Chipset | Intel®
5520 chipset NOTE: For more information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/. |
| | |
| Memory Protection | Advanced ECC |
| Mirroring mode | |
| Lockstep mode | |
|
| |
| Memory One of the following depending on Model | Type | DDR3 Registered (RDIMM) or Unbuffered (UDIMM) |
| Standard (Performance Models) | 12 GB (6 x 2 GB) RDIMM | |
| Standard (Base Models) | 6 GB (3 x 2 GB) RDIMM | |
| Standard (Entry Model) | 4 GB (2 x 2 GB) RDIMM | |
| Maximum (RDIMM) | 192 GB (12 x 16 GB) for Registered Memory configurations | |
| Maximum (UDIMM) | 24 GB (12 x 2 GB) for Unbuffered Memory configurations | |
| NOTE:
Depending on the memory configuration and processor model, the memory speed may
run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration
Tool at: www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient. | ||
| DDR3 memory options part number decoder | ||
![]() | ||
| | ||
| Network Controller | HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter |
|
| |
| Expansion Slots | Expansion
Slots # |
Technology |
Bus Width |
Connector Width |
Form Factor |
Notes |
|
1 |
PCIe | x4 | x8 | Half length, full height | ||
| 2 | PCIe2 | x4 | x8 | Full
Length/Full Height | ||
| 3 |
PCIe2 | x16 | x16 | Full
Length/Full Height | ||
| 4 |
PCIe2 | x4 | x8 | Full
Length/Full Height | ||
| 5 | PCIe2 | x4 | x8 | Full
Length/Full Height | ||
| 6 |
PCIe2 | x8 | x16 | Full
Length/Full Height | ||
| 7 |
PCIe2 | x4 | x8 | Full
Length/Full Height | ||
| 8 | PCIe2 | x16 | x16 | Full
Length/Full Height | ||
| 9 |
PCIe2 | x4 | x8 | Full
Length/Full Height | ||
10 | PCIe2 | X8 | X8 | Half length, full height | Utilized by NIC controller "Use the correct model number for the NIC" | |
| 11 | PCI-X | See note | See note | Full Length/Full Height | (optional) *Up
to 64bits/133Mhz speed when only one device install in slot 11 and 12 *up to 64bits/100Mhz speed when both slot 11 and 12 are utilized. |
|
| 12 | PCI-X | See note | See note | Full Length/Full Height | (optional) | |
| *Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number. | ||||||
| | ||||||
| Storage
Controller One of the following depending on Model | Entry Models | HP Smart Array P410i/256 MB Controller (RAID 0/1/1+0/5/5+0) |
| Base Models | HP Smart Array P410i/256 MB Controller (RAID 0/1/1+0/5/5+0) | |
| Performance Models | HP Smart Array P410i/512 MB BBWC Controller (RAID 0/1/1+0/5/5+0/6) | |
| Available upgrades: 256MB, 512MB with BBWC, 512MB with FBWC, 1G with FBWC, Battery kit upgrade (for BBWC), and Smart Array Advanced Pack (SAAP). | ||
| | ||
| Storage | Diskette Drive | None Standard |
| Optical Drive | SATA DVD ROM (standard in all models) | |
| Hard Drives | None Standard | |
| | ||
| Maximum Internal Storage Type | Hot Plug
SFF SAS | 7.20TB | 24 x 300GB |
| Hot Plug LFF SAS | 14 TB | 14 x 1TB | |
| | |||
| Interfaces | Serial | 1 (rear) |
| Pointing Device
(Mouse) | 1 | |
| VGA | 1 (+1 front VGA on rack models) | |
| Keyboard | 1 | |
| Network RJ-45 (Ethernet) | 4 (rear) | |
| ILO 2.0 remote
management port | 1 | |
| SD slot | 1 | |
| USB 2.0 Ports | 5
(2 on the rear, 2 on the front, 1 internal) NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html | |
| Dedicated USB 2.0 Port | 1 (available for
DAT USB tape connectivity) NOTE: Internal USB ports are optimal for the attachment of HP DAT USB Internal Tape Drives | |
| | ||
| Graphics | Integrated
ATI RN50, 64 MB video standard
NOTE: Maximum resolution available via iLO 2 remote console is 1280 x 1024. |
| | |
| Form Factor | 4U Rack and Tower form factor (7 in, 17.8 cm) |
| | |
| HP Insight management software | HP Insight Foundation |
Managing the growing number of servers can be complex and expensive for your organization. IT managers need to address changing business needs with tools that meet the challenges of managing today's complex Datacenters. HP provides
management solutions that are designed to simplify a server's installation, configuration
and maintenance throughout the entire server lifecyle. This provides the customer
with higher levels of operational efficiency and highly reliable systems: www.hp.com/go/foundation.
SmartStart version supported (minimum):
SmartStart 8.20 |
| ProLiant Onboard Administrator |
HP ProLiant Onboard Administrator (powered by the HP Integrated Lights-Out 2 management processor) simplifies server setup, health monitoring, power and thermal control, and lights-out remote administration of ProLiant ML, DL, and BL servers. HP ProLiant Onboard Administrator functions without additional software, and can be accessed from any location via a web browser. It works hand-in-hand with HP Systems Insight Manager, Insight Control suites, and the Insight Dynamics for ProLiant helping customers unlock the value of the ProLiant platform and deliver the highest possible quality of IT service to the business. See www.hp.com/go/ProLiantOA | |
| HP Insight Control |
HP Insight Control, a product option, delivers essential infrastructure
management that can help save time and money by making it easy to deploy,
migrate, monitor, remote control, and optimize your IT infrastructure
through a single, simple management console. | |
| HP Insight Dynamics for ProLiant | HP Insight Dynamics
for ProLiant, a product option, is an integrated command center that enables
IT Staff personnel to continuously analyze and optimize a converged infrastructure,
while automating and reducing the cost of common data center tasks by as
much as 40 percent. As a powerfully integrated by design toolkit to accelerate
complex technology projects and simplify daily operations that ultimately
enable IT Staff personnel to dynamically keep pace with the organizations
changing business requirements. It enables them to plan capacity and power
continuously, balance across physical and virtual resources, and ensure
cost-effective high availability. It also enables IT organizations to provision
infrastructure consistently and automatically from pools of shared resources
using a self-service portal. Resources provisioned can range from a single
virtual machine to complex multi-tier environments and their associated
physical and virtual resource requirements. In addition to the previous
functional benefits, it also provides a cost-effective disaster recovery
for physical and virtual environments that works with HP StorageWorks Continuous
Access software for both the Enterprise Virtual Array and the XP storage
array allowing application environments to be reactivated in minutes with
the touch of a button to a remote location. NOTE: For more information, visit: http://www.hp.com/go/insightdynamics |
|
| | ||
| Industry Standard Compliance | ACPI V2.0
Compliant PCI-Express Gen2 PXE Support WOL Support Microsoft® Logo certifications USB 2.0 Support SMBIOS 2.6.1 |
|
| |
| Security | Power-on password Keyboard password Diskette drive control Diskette boot control QuickLock, Network Server Mode Serial interface control Administrator's password |
| | |
| Security Trusted Platform Module |
Trusted Platform Module option kit |
|
| |
| Server Power Cords | High voltage power
cord ships standard with all part numbers. NOTE: ProLiant DL servers no longer ship standard with NEMA power cords (187335-001) that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected to PDU's in data center racks so they now ship standard with only a PDU power cord (416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle (NEMA-15), the above NEMA power cord must be ordered separately. |
|
| |
| UPS Power Cord Matrix | Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Power Cords, click on the HP Power Cord Matrix link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords. |
| | |
| Power
Supply One of the following depending on Model |
HP has a new design for ProLiant power- the new Common Slot Power Supply bay. This design provides the customer with commonality in power supplies across multiple platforms to save on the cost of spares and allows HP to offer multiple power solutions to fit the customers' needs. Many HP ProLiant Servers come with Common Slot, High Efficiency and Right-Size Power Supplies. The new HP Common Slot power supplies are designed for the highest power efficiency without degrading performance of the ProLiant server. Power Supplies have efficiency ratings up to 92%. There are three Right Size power options available depending on the configuration of your server. To make sure you select the correct power supply to meet your configuration, please use the HP Power Advisor at www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor. All HP Common Slot power sources are UL, CE Mark Compliant, Hot Plug and Redundant. |
| | |
| Common Slot ProLiant |
It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for your needs. HP offers four Power Supply Options:
HP's ProLiant Common Slot Power supplies (460W & 750W) meet multiple
Energy Efficiency Initiatives. Climate Savers Computing Initiative GOLD,
ECOS Consulting 80PLUS GOLD and plans on offering models that meet the
Energy Star for Server requirements when they are published. |
|
| |
| System Fans | (3) Hot Plug fans ship standard NOTE: For full redundancy you can purchase the HP ML370 G6 and DL370 G6 Redundant Fan Kit; PN: 508107-B21. |
| | |
| Required Cabling | For external storage cabling information, refer to the Web site at: www.hp.com/servers/dl370 or www.hp.com/servers/ml370. |
| | |
| Operating Systems and Virtualization Software Support for ProLiant Servers |
Microsoft
Windows Server |
|
NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/ossupport and our driver download page http://www.hp.com/support/ML370G6. | |
| | |
| Rack Airflow Requirements | Rack
10000 G2 series Cabinets
CAUTION: Always use blanking panels
to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in
improper cooling that can lead to thermal damage. |
| | |
| Rack Kit | Quick deploy rail system provides tool-free support for racks with square or round mounting holes (including Compaq/HP 7000, 9000, 10000 G2 and HP series), with an adjustment range of 24" - 36". The ambidextrous cable management arm can be mounted on either the left or right side for improved cable management. |
|
| |
| Telco Rack Support |
Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions at: www.hp.com/go/rackandpower. |
| | |
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and
deployment services for HP servers and storage products. Customers can
choose how their factory solutions are built, tested, integrated, shipped
and deployed. |
| | |
| HP Enterprise Configurator | The HP eConfigure Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. http://www.hp.com/products/configurator |
| | |
| Service and Support | HP Care Pack
services provide total care and support expertise with committed response designed
to meet your IT and business needs.
Enhanced Service - optimize service level to increase IT performance and availability.
Refer to the information on "Installation
& Start-Up" for service on ProLiant server and Microsoft or Linux O/S
per the Customer Description and/or Data Sheet; to be delivered on a scheduled
basis 8am-5pm, M-F, excluding HP holidays. |
|
|
HPC Interconnects
| NOTE: High Performance Computing (HPC) interconnect technologies are available for this server under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects: http://www.hp.com/techservers/clusters/ucp/index.html. |
| |
| HPC Interconnect | InfiniBand | PCI-X and PCI-Express adapters |
| Gigabit Ethernet | Use embedded ports | |
| Myrinet XP | PCI-X Rev D and Rev E adapters |
|
|
Models
|
Base Models | ||
| HP
ProLiant DL370 G6 E5530 2.40GHz Quad Core SFF Base Rack Server 487794-001 | Processor | (1) Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) |
| Cache Memory | 8MB (1 x 8MB) L3 cache | |
| Memory | 6GB (3 x 2GB) PC3-10600 (DDR3-1333) Registered DIMMs | |
| Network Controller | HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410i/256MB Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed) | |
| Optical Drive | SATA DVD ROM | |
| PCI-Express Slots | 10 slots - (9) available PCI-e Gen2 slots (NOTE: 10 slots available, one is taken by the NIC riser card) | |
| Power Supply | (1) 750W Hot Plug Power Supply | |
| Fans | (3) Hot Plug Fans | |
| Form Factor | 4U Rack | |
| | ||
| Performance Models | ||
|
HP ProLiant DL370 G6 X5550 2.66GHz Quad Core SFF High Performance Rack
Server | Processor | (2) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) |
| Cache Memory | 8MB (1 x 8MB) L3 cache | |
| Memory | 12GB (6 x 2GB) PC3-10600 (DDR3-1333) Registered DIMMs | |
| Network Controller | HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410i/512MB with BBWC | |
| Hard Drive | None ship standard | |
| Internal Storage | (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed) | |
| Optical Drive | SATA DVD ROM | |
| PCI-Express Slots | 10 slots - (9) available PCI-e Gen2 slots (NOTE: 10 slots available, one is taken by the NIC riser card) | |
| Power Supply | (2) 750W Redundant Hot Plug Power Supplies | |
| Fans | (5) Fully Redundant Hot Plug Fans | |
| Form Factor | 4U Rack | |
| | ||
|
HP ProLiant DL370 G6 X5550 2.66GHz Quad Core SFF Performance ICE Rack
Server |
Processor | (2) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) |
| Cache Memory | 8MB (1 x 8MB) L3 cache | |
| Memory | 12GB (6 x 2GB) PC3-10600 (DDR3-1333) Registered DIMMs | |
| Network Controller | HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410i/512MB with BBWC | |
| Manageability | HP Insight Control Environment No Media single server license, including 1 year of 24x7 Technical Support and Updates | |
| Hard Drive | None ship standard | |
| Internal Storage | (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed) | |
| Optical Drive | SATA DVD ROM | |
| PCI-Express Slots | 10 slots - (9) available PCI-e Gen2 slots (NOTE: 10 slots available, one is taken by the NIC riser card) | |
| Power Supply | (2) 750W Redundant Hot Plug Power Supplies | |
| Insight Control Environment (ICE) | HP Insight Control Environment No Media single server license, including 1 year of 24x7 Technical Support and Updates | |
| Fans | (5) Fully Redundant Hot Plug Fans | |
| Form Factor | 4U Rack | |
|
|
||
| Base Tower Models: Quad-Core | ||
|
HP ProLiant ML370 G6 E5540 2.53GHz Quad Core SFF Base Tower Server | Processor |
(1) Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) |
| Cache Memory | 8MB (1 x 8MB) L3 cache | |
| Memory | 6GB (3 x 2GB) PC3-10600 (DDR3-1333) Registered DIMMs | |
| Network Controller | HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410i/256MB Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed) | |
| Optical Drive | SATA DVD ROM | |
| PCI-Express Slots | 10 slots - (9) available PCI-e Gen2 slots (NOTE: 10 slots available, one is taken by the NIC riser card) | |
| Power Supply | (1) 750W Hot Plug Power Supply | |
| Fans | (3) Hot Plug Fans | |
| Form Factor | 4U Tower | |
| | ||
| Entry Tower Models: Quad-Core | ||
|
HP ProLiant ML370 G6 E5520 2.26GHz Quad Core SFF Entry Tower Server | Processor | (1) Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) |
| Cache Memory | 8MB (1 x 8MB) L3 cache | |
| Memory | 4 GB (2 x 2 GB) PC3-10600 (DDR3-1333) Registered DIMMs | |
| Network Controller | HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410i/256MB Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed) | |
| Optical Drive | SATA DVD ROM | |
| PCI-Express Slots | 10 slots - (9) available PCI-e Gen2 slots (NOTE: 10 slots available, one is taken by the NIC riser card) | |
| Power Supply | (1) 460W Hot Plug Power Supply | |
| Fans | (3) Hot Plug Fans | |
| Form Factor | 4U Tower | |
|
|
Smart Buys
|
The ProLiant Smart Buy program offers a collection of promotional server and option products that are configured with SMB in mind, offered at discounted prices, and positioned for quick delivery. Smart Buy server offers are available for a limited time only. |
||
| S-Buy ML370G6
E5530 6GB SFF 519578-005 |
Processor(s) | (1) Intel® Xeon® Processor E5530 (2.40 GHz, 80 Watts, DDR3-1066) |
| Cache Memory | 8MB Level 3 cache | |
| Memory | 6 GB (3x 2GB 2Rx8 PC3-10600R-9 Kit) | |
| Network Controller | NC375i Integrated Quad Port Multifunction Gigabit Server Adapter | |
| Storage Controller | Smart Array P410i/512MB BBWC | |
| Hard Drive | None included | |
| Internal Storage | Up to 8 SFF standard, up to 24 SFF with 2 additional drive cages | |
| Optical Drive | Half-Height SATA DVD-ROM Drive | |
| Power Supply | (2) HP 750-Watt CS HE Power Supply Kit | |
| Fans | 3 standard Hot Plug fans, 5 total Hot Plug fans supported (with addition of Redundant Fan Kit) | |
| Form Factor | 4U Tower | |
|
|
||
| S-Buy DL370G6
E5540 8GB SFF 519577-005 |
Processor(s) | (2) Intel® Xeon® Processor E5540 (2.53 GHz, 80 Watts, DDR3-1066) |
| Cache Memory | 8MB Level 3 cache | |
| Memory | 8 GB (2x 4GB 2Rx4 PC3-10600R-9 Kit) | |
| Network Controller | NC375i Integrated Quad Port Multifunction Gigabit Server Adapter | |
| Storage Controller | Smart Array P410i/512MB BBWC | |
| Hard Drive | None included | |
| Internal Storage | Up to 8 SFF standard, up to 24 SFF with 2 additional drive cages | |
| Optical Drive | Half-Height SATA DVD-ROM Drive | |
| Power Supply | (2) HP 1200-Watt CS HE Power Supply Kit | |
| Fans | (5) Fully Redundant Hot Plug Fans (3 standard + Redundant Fan Kit) | |
| Form Factor | 4U Rack |
|
|
Configuration Information - Factory Integrated Models
|
NOTE: This section lists some of the steps required to configure a Factory
Integrated Model. To ensure only valid configurations are ordered, HP recommends
the use of an HP approved configurator. Contact your local sales representative
for information on CTO product offerings and requirements. | ||
| Step 1: Base Configuration (choose one of the following configurable models) | ||
| Models | HP
ProLiant ML370 G6 Tower Models | |
| HP
ProLiant ML370 G6 SFF CTO Chassis NOTE: Supports Small Form Factor (SFF) - 2.5" Drives | 483880-B21 | |
| Factory Integrated Model ships with: | ||
| HP NC375i Integrated
Quad Port Multifunction Gigabit Server Adapter | ||
| HP ProLiant ML370
G6 Tower CTO Chassis | ||
| HP ProLiant ML370
G6 LFF CTO Chassis NOTE: Supports Large Form Factor (LFF) - 3.5" Drives | 483879-B21 | |
| Factory
Integrated Model ships with: | ||
| HP NC375i Integrated
Quad Port Multifunction Gigabit Server Adapter Integrated Lights-Out embedded HP Smart Array P410i/Zero Memory Controller (6) Hot-Plug (LFF) SAS/SATA Drive Bays (9) available PCI-e Gen2 slots (5) USB ports (3) Hot Plug Fans Tower Form Factor | ||
| HP ProLiant DL370
G6 Rack Models | ||
| HP ProLiant DL370
G6 SFF CTO Chassis NOTE: Supports Small Form Factor (SFF) - 2.5" Drives |
483874-B21 | |
| Factory
Integrated Model ships with: | ||
| HP NC375i Integrated
Quad Port Multifunction Gigabit Server Adapter Integrated Lights-Out embedded HP Smart Array P410i/Zero Memory Controller (8) Hot-Plug (SFF) SAS/SATA Drive Bays (9) available PCI-e Gen2 slots (5) USB ports (3) Hot Plug Fans 4U Rack Form Factor | ||
| HP ProLiant DL370
G6 LFF CTO Chassis NOTE: Supports Large Form Factor (LFF) - 3.5" Drives | 483873-B21 | |
| Factory Integrated
Model ships with: | ||
| HP NC375i Integrated
Quad Port Multifunction Gigabit Server Adapter Integrated Lights-Out embedded HP Smart Array P410i/Zero Memory Controller (6) Hot-Plug (LFF) SAS/SATA Drive Bays (9) available PCI-e Gen2 slots (5) USB ports (3) Hot Plug Fans 4U Rack Form Factor | ||
| | ||
| Step 2: Choose Required Options (only one of the following from each list) | ||
| Processors | NOTE: If High Performance Model features are desired, 2nd processor is included in the Performance Pack part numbers in Step 3 below. | |
| Quad-Core Processors | ||
| Intel® Xeon® Processor W5580 (3.20 GHz, 8MB L3 Cache, 130W, DDR3-1333, HT, Turbo 1/1/1/2), FIO | 495928-L21 | |
| Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO | 495930-L21 | |
| Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO |
495932-L21
|
|
| Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO |
495934-L21
|
|
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO |
495936-L21
|
|
| Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO |
495938-L21
|
|
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO |
495940-L21
|
|
| Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO | 495942-L21 | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO |
495944-L21
|
|
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2), FIO | 505511-L21 | |
| Dual-Core Processors | ||
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO | 495946-L21 | |
| Base Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit |
500656-B21
|
|
| HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21
|
|
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit |
500660-B21
|
|
| HP 8GB 2Rx4 PC3-8500R-7 Kit | 516423-B21 | |
| HP 8GB 2Rx4 PC3-10600R-9 Kit |
500662-B21
|
|
| HP 16GB 4Rx4 PC3-8500R-7 Kit | 500666-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE:
All DDR3 memory option kits consist of one DIMM per kit. For detailed memory
configuration rules and guidelines, please use the Online DDR3 Memory Configuration
Tool: www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient |
||
| Power Supply | NOTE: Refer to HP Power Advisor when selecting a power supply for your configuration, www.hp.com/go/hppoweradvisor. Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor | |
| HP 460W CS HE Gold Power Supply | 503296-B21 | |
| HP 750W CS HE Gold Power Supply | 512327-B21 | |
| HP 1200W CS HE Silver Power Supply | 500172-B21 | |
| NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. | ||
|
|
||
| Step 3: Choose Additional Factory Integratable Options | ||
| Controllers | NOTE: If Additional Memory Cache Module or Controller is Required please pick one of the following: | |
| 256MB Cache Module
FIO NOTE: Available for P410i only. |
534108-B21 | |
| 512MB BBWC | 462967-B21 | |
| 512MB Flash Backed
Write Cache NOTE: Supported on the Smart Array P410i Controller only. |
534916-B21 | |
| 1G Flash Backed Write
Cache NOTE: Supported on the Smart Array P410i Controller only. |
534562-B21 | |
| HP Smart Array P212/256 MB w/ Battery FIO | 491191-B21 | |
| HP Smart Array P410/256 MB w/ Battery FIO | 491195-B21 | |
| HP Smart Array P411/256 MB w/ Battery FIO | 491193-B21 | |
| Performance Packs | Performance Packs
are necessary to configure a HP ProLiant DL370 G6 or a HP ProLiant ML370
G6 to a High Performance Model which includes the latest performance technologies
and enterprise class availability features pre-installed for convenience
and value. The Performance Pack includes a 2nd processor, redundant fans,
power supply, and memory expansion board. NOTE: Must also select 447326-B21 to achieve parity to DL370 G6 or ML370 G6 High Performance Models. |
|
| HP ML370 G6 and DL370 G6 X5550 HPM FIO Perf Kit |
516727-B21
|
|
|
|
||
| Step 4: Choose Additional Options for Factory Integration |
| NOTE: For additional options, please refer to the "Core Options" and "Additional Options" section below. |
|
|
Core Options
NOTE: Some options may not be available for factory integration. Please contact an HP sales representative for additional information. | ||
| Unique Options | (8) Small Form Factor (SFF) 2nd Drive Cage Kit | 507803-B21 |
| (6) Large Form Factor (LFF) Backplane Kit | 507810-B21 | |
| (2) Large Form Factor (LFF) Drive Cage Kit | 487936-B21 | |
| HP ML370 G6 Tower to Rack Conversion Kit | 515031-B21 | |
| HP ML370 G6 and DL370 G6 Redundant Fan Kit | 508107-B21 | |
| HP ML370 G6 and DL 370 G6 Graphic
Card Adapter Kit NOTE: An option kit will be required per Graphic Card) NOTE: 2 PCIe Gen2 x16 (mechanical/electrical); 1 PCIe Gen2 x16 (mechanical) x8 (electrical) |
537721-B21 | |
| HP ML370 G6 and DL370 G6 Smart-mini
DIMM Module NOTE: By plugging the Smart-mini DIMM Module to the HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter, TCP/IP Offload Engine (TOE) for Windows is enabled/supported. |
519808-B21 | |
| HP ML370 G6 and DL370 G6 PCI-X
Riser Kit NOTE: Customers purchasing the PCI-X Riser Kit, must also purchase the Redundant Fan kit (508107-B21) |
516434-B21 | |
| | ||
| Processors | Quad-Core Processors | |
| Intel® Xeon® Processor W5580 (3.20 GHz, 8MB L3 Cache, 130W, DDR3-1333, HT, Turbo 1/1/1/2) | 495928-B21 | |
| Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | 495930-B21 | |
| Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | 495932-B21 | |
| Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | 495934-B21 | |
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | 495936-B21 | |
| Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | 495938-B21 | |
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | 495940-B21 | |
| Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) | 495942-B21 | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) | 495944-B21 | |
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) | 505511-B21 | |
| Dual-Core Processors | ||
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) | 495946-B21 | |
| | ||
|
Memory |
Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit |
500656-B21
|
|
| HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21
|
|
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit |
500660-B21
|
|
| HP 8GB 2Rx4 PC3-8500R-7 Kit | 516423-B21 | |
| HP 8GB 2Rx4 PC3-10600R-9 Kit |
500662-B21
|
|
| HP 16GB 4Rx4 PC3-8500R-7 Kit | 500666-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient |
||
|
|
||
|
Optical Drives |
HP Half-Height SATA DVD-ROM Optical Drive | 447326-B21 |
| HP Half-Height SATA DVD-RW Optical Drive | 447328-B21 | |
| HP Slim SATA DVD-ROM Optical Drive | 481041-B21 | |
| HP Slim SATA DVD RW Optical Drive | 481043-B21 | |
| | ||
| Hard Drives | NOTE: The components
of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and
the server backplane) should operate at the same data transfer rate or the
system bandwidth will be negotiated down to an acceptable level for all
components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. |
|
| SAS Hot Plug SFF Enterprise (ENT) Drives | ||
| HP 300GB 6G SAS 10K SFF DP ENT HDD |
507127-B21
|
|
| HP 300GB 3G SAS 10K SFF DP ENT HDD |
492620-B21
|
|
| HP 146GB 6G SAS 15K SFF DP ENT HDD | 512547-B21 | |
| HP 146GB 3G SAS 15K SFF DP ENT HDD | 504062-B21 | |
| HP 146GB 6G SAS 10K SFF DP ENT HDD | 507125-B21 | |
| HP 146GB 3G SAS 10K SFF DP ENT HDD |
418367-B21
|
|
| HP 72GB 6G SAS 15K SFF DP ENT HDD |
512545-B21
|
|
| HP 72GB 3G SAS 15K SFF DP ENT HDD | 418371-B21 | |
| HP 72GB 3G SAS 10K SFF DP ENT HDD |
384842-B21
|
|
| SAS Hot Plug 3.5" Enterprise (ENT) Drives | ||
| HP 600GB 6G SAS 15K 3.5" DP ENT HDD | 516828-B21 | |
| HP 450GB 6G SAS 15K 3.5" DP ENT HDD |
516816-B21
|
|
| HP 450GB 3G SAS 15K 3.5" DP ENT HDD | 454232-B21 | |
| HP 300GB 6G SAS 15K 3.5" DP ENT HDD | 516814-B21 | |
| HP 300GB 3G SAS 15K 3.5" DP ENT HDD | 416127-B21 | |
| HP 146GB 3G SAS 15K 3.5" DP ENT HDD | 384854-B21 | |
| SAS Hot Plug SFF Midline (MDL) Drives | ||
| HP 500GB 6G SAS 7.2K SFF DP MDL HDD | 507610-B21 | |
| SAS Hot Plug 3.5" Midline (MDL) Drives | ||
| HP 1TB 3G SAS 7.2K 3.5" DP MDL HDD | 461137-B21 | |
| HP 750GB 3G SAS 7.2K 3.5" DP MDL HDD | 461135-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12244_na/12244_na.html |
||
| SATA Hot Plug SFF Midline (MDL) Drives | ||
| HP 500GB 3G SATA 7.2K 2.5in MDL HDD | 507750-B21 | |
| HP 160GB 3G SATA 7.2K 2.5in MDL HDD | 530888-B21 | |
| SATA Hot Plug 3.5" Midline (MDL) Drives | ||
| HP 1TB 3G SATA 7.2K 3.5" MDL HDD | 454146-B21 | |
| HP 750GB 3G SATA 7.2K 3.5" MDL HDD | 458930-B21 | |
| HP 500GB 3G SATA 7.2K 3.5" MDL HDD | 458928-B21 | |
| HP 250GB 3G SATA 7.2K 3.5" MDL HDD | 458926-B21 | |
| SATA Hot Plug 3.5" Entry (ETY) Drives | ||
| HP 160GB 3G SATA 7.2K 3.5" ETY HDD | 458945-B21 | |
| SATA Hot Plug SFF Entry (ETY) Drives | ||
| HP 250GB 3G SATA 5.4K SFF ETY HDD | 460355-B21 | |
| HP 120GB 1.5G SATA 5.4K SFF ETY HDD | 458924-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13021_na/13021_na.html |
||
| SATA Hot Plug Midline (MDL) Solid State Drives | ||
| HP 60GB 3G SATA 2.5in MDL 1y Wty SSD | 572071-B21 | |
| HP 120GB 3G SATA 2.5in MDL 1y Wty SSD | 572073-B21 | |
| SATA Hot Plug 3.5" Midline (MDL) Solid State Drives | ||
| HP 60GB 3G SATA 3.5in MDL 1y Wty SSD | 570761-B21 | |
| HP 120GB 3G SATA 3.5in MDL 1y Wty SSD | 570763-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13415_na/13415_na.html |
||
|
|
||
| Communications | Networking | |
| Gigabit Ethernet adapters | ||
| HP NC112T PCIe Gigabit Server Adapter |
503746-B21
|
|
| HP NC360T PCI Express Dual Port Gigabit Server Adapter |
412648-B21
|
|
| HP NC364T PCI Express Quad Port
Gigabit Server Adapter NOTE: There is a maximum of five NC364T PCI Express Quad Port Gigabit Server Adapters allowed in this server. |
435508-B21
|
|
| HP NC373F PCI Express Multifunction Gigabit Server Adapter |
394793-B21
|
|
| HP NC373T PCI Express Multifunction Gigabit Server Adapter |
394791-B21
|
|
| HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter |
458492-B21
|
|
| HP NC375T PCI Express Quad Port Gigabit Server Adapter | 538696-B21 | |
| 10 Gigabit Ethernet adapters | ||
| HP NC522SFP Dual Port 10GbE Gigabit
Server Adapter NOTE: A minimum of two Gigabytes (2 GB) of server memory is required per each NC522SFP adapter. NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately. |
468332-B21
|
|
| HP NC524SFP Dual Port 10GbE Server
Adapter NOTE: One NC524SFP allowed per system; a minimum of two gigabytes (2 GB) of server memory is required for the NC524SFP module. NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately. |
489892-B21 | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs. | ||
| Smart-mini DIMM Module | ||
| HP ML370 G6 and DL370 G6 Smart-mini
DIMM Module NOTE: By plugging the Smart-mini DIMM Module to the HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter, TCP/IP Offload Engine (TOE) for Windows is enabled/supported. |
519808-B21 |
|
| Riser
Cage Options |
HP DL370 G6 2 Slot PCI-X Riser
Kit NOTE: Customers purchasing the PCI-X Riser Kit, must also purchase the Redundant Fan kit (508107-B21) |
516434-B21 |
| Power Supplies | CAUTION: Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor. In ProLiant Servers that have more than one power slot (bay), only same size power supplies are recommended. If non-matched power supplies are inserted you will get errors and operation will fail. | |
| HP 460W CS HE Gold Power Supply |
503296-B21
|
|
| HP 750W CS HE Gold Power Supply |
512327-B21
|
|
| HP 1200W CS HE Silver Power Supply |
500172-B21
|
|
| NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. | ||
| Power Options | ||
| HP ML370 G6 and DL370 G6 Redundant Fan Kit | 508107-B21 |
|
|
Additional Options
| HP Insight Software | HP Insight Control server deployment | |
|
HP Insight Control server deployment, Electronic License including 1 year of 24x7 Technical Support and Updates |
T9082AAE | |
| NOTE: Electronic
and Flexible-Quantity licenses can be used to purchase multiple licenses
with a single activation key. NOTE: Electronic software is available in all countries except China and Japan. Customers in China and Japan should order the physical equivalent. NOTE: Customer will receive a license entitlement certificate. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: Licenses ship without media. The HP Insight Control Media Kit can be ordered separately, or can be downloaded at: http://www.hp.com/go/insightupdates. NOTE: For additional license options please see the Insight Control QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12631_na/12631_na.html |
||
| HP Insight Control for Linux | ||
| HP Insight Control for Linux, 1-server license, including one year of 24x7 Technical Support and Updates, Electronic | T9084BAE | |
| HP Insight Control for Linux, No Media, 1-Server license, including one year of 24x7 Technical Support and Updates | 464423-B22 | |
| HP Insight Control for Linux,
Media pack (DVD) - No licenses included NOTE: Media pack DVD contains HP Insight Control for Linux, HP Systems Insight Manager, HP Insight Control power management, HP Insight Control virtual machine management, and an integrated installer. Servers must be acquired separately. |
464422-B22 | |
| NOTE: Licenses
ship without media. The HP Insight Control Media Kit can be ordered separately,
or can be downloaded at: http://www.hp.com/go/insightupdates.
NOTE: Electronic software is available in all countries except China and Japan. Customers in China and Japan should order the physical equivalent. NOTE: Electronic and Flexible-Quantity licenses can be used to purchase multiple licenses with a single set of activation keys. NOTE: For additional License Kits, including electronic licensing options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_na/13019_na.html |
||
| HP Integrated Lights-Out Advanced | ||
| HP Integrated Lights-Out Advanced,
No Media, 1-Server License, including 1 year of 24x7 Technical Support and
Updates NOTE: This license allows 1 server to be deployed and managed via HP iLO Advanced. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service NOTE: For additional license kits, including electronic delivery options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12362_na/12362_na.html |
512485-B21 | |
| HP Insight Rapid Deployment software | ||
| HP Insight Rapid Deployment
software No Media 1-Server License including 1 year of 24x7 Technical Support
and Updates NOTE: This license allows 1 server to be deployed and managed via RDP. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service NOTE: For additional license kits, including electronic delivery options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.html |
452151-B21 | |
|
|
||
| Drive Cage Options | (8) Small Form Factor (SFF) 2nd Drive Cage Kit | 507803-B21 |
| (6) Large Form Factor (LFF) Backplane Kit |
507810-B21
| |
| (2) Large Form Factor (LFF) Drive Cage Kit |
487936-B21
|
|
Graphic Cards |
HP ML370 G6 and DL370 G6 Graphic
Card Cable Kit NOTE: An option kit will be required per Graphic Card. |
537721-B21 |
| NOTE: 2 PCIe Gen2 x16 (mechanical/electrical); 1 PCIe Gen2 x16 (mechanical) x8 (electrical) |
|
| Security | HP Trusted Platform Module Option Kit |
488069-B21
|
|
| ||
| Storage Controllers | SAS Controllers | |
| HP Smart Array P800 Controller | ||
| HP Smart Array P800/512 BBWC Controller | 381513-B21 | |
| HP Smart Array P212 Controller | ||
| HP Smart Array P212/Zero Memory Controller |
462828-B21 |
|
| HP Smart Array P212/256 MB Controller | 462834-B21 | |
| HP Smart Array P410 Controller |
|
|
| HP Smart Array P410/256 MB Controller | 462862-B21 | |
| HP Smart Array P410/512 MB with BBWC Controller | 462864-B21 | |
| HP Smart Array P411 Controller | ||
| HP Smart Array P411/256 MB Controller | 462830-B21 | |
| HP Smart Array P411/512 MB with BBWC Controller | 462832-B21 | |
| Optional Upgrades | ||
| 256 MB Cache Module NOTE: Supported on HP Smart Array P212 Controller only. |
462968-B21 | |
| 512MB BBWC | 462967-B21 | |
| Battery Kit upgrade NOTE: To enable BBWC on the 256MB cache. NOTE: Supported on HP P410i Smart Array (integrated), HP Smart Array P212 Controller, HP Smart Array P410 Controller, and HP Smart Array P411 Controller only. |
462969-B21 | |
| 1G Flash Backed Write Cache NOTE: Supported on the Smart Array P410i Controller only. |
534562-B21 | |
| 512MB Flash Backed Write Cache NOTE: Supported on the Smart Array P410i Controller only. |
534916-B21 | |
| HP 8484 to Mini SAS 33in Cable
Assy NOTE: Needed to support internal drives on the HP ProLiant DL370 G6 or the HP ProLiant ML370 G6 with the Smart Array P800 Controller. |
591734-B21 | |
| HP Smart Array Advanced Pack No
Media 1-Server license including 1yr 24x7 Technical Support NOTE: This part number can be used to purchase a single license or to order multiple licenses with a single activation key. Customers will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Include one year of 24x7 HP Software Technical Support Services. |
516471-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12616_na/12616_na.html (Smart Array P800 Controller) http://h18000.www1.hp.com/products/quickspecs/13203_na/13203_na.html (Smart Array P212 Controller) http://h18000.www1.hp.com/products/quickspecs/13201_na/13201_na.html (Smart Array P410 Controller) http://h18000.www1.hp.com/products/quickspecs/13202_na/13202_na.html (Smart Array P411 Controller) |
||
| SAS Controller Options | ||
| HP SAS Expander Card NOTE: For use with the additional 8 SFF drive cage (507803-B21). |
468406-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information: http://h18004.www1.hp.com/products/quickspecs/13232_na/13232_na.html (SAS Expander Card) |
||
| SAS HBA | ||
| HP SC08Ge Host Bus Adapter | 488765-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information: http://h18004.www1.hp.com/products/quickspecs/13082_na/13082_na.html (SC08Ge HBA) |
||
|
|
||
| Power Cords | NOTE: HP ProLiant servers ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). | |
| Nema 5-15P to IEC320-C13, low voltage (6 ft/2 m) | AF556A |
|
| Tape Storage |
NOTE: For the complete listing of Tape Drive offerings, please
see: |
|
| Tape Drives | ||
| USB Rack-Mount Tape Solutions | ||
| HP StorageWorks DAT 160 USB Internal Drive |
Q1580A
|
|
| DAT 320 WW SAS External Tape Drive | AJ828A | |
| DAT 320 USB External Tape Drive | AJ823A | |
| HP DAT 320 USB Internal Tape Drive | AJ825A | |
| HP 1U DAT320 USB Rack Enclosure | AP835A | |
| SAS Rack-Mount Tape Solutions | ||
| HP DAT 320 SAS Internal Tape Drive | AJ830A | |
| HP StorageWorks LTO-2 Ultrium 448 SAS Internal Tape Drive | DW085A | |
| HP StorageWorks LTO-3 Ultrium 920 SAS Internal Tape Drive | EH847A | |
| HP StorageWorks LTO-4 Ultrium 1760 SAS Internal Tape Drive |
EH919A
|
|
| NOTE:
For the ML370 G6, HP recommends purchasing the HP Smart Array P212 Controller
(462828-B21) for a dedicated SAS HBA for tape. NOTE: Please refer to the "Tape Drives, Tape Autoloaders & Tape Libraries" table in the Storage section of this document for a list of SAS controllers with tape support. |
||
| HP StorageWorks 1/8 G2 Tape Autoloader | ||
| HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader | AK377A | |
| HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Autoloader | AH558A | |
| HP StorageWorks 1/8 G2 Tape Autoloader Rack Kit | AH166A | |
| NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions. | ||
| NOTE: Please reference the Tape Autoloader QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs. | ||
| HP StorageWorks MSL2024 Tape Library | ||
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SAS Drive Library | AK378A | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SAS Drive Library | AH559A | |
| HP StorageWorks MSL4048 Tape Library | ||
| HP StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SAS Drive Library | AK380A | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SAS Drive Library | AH560A | |
| NOTE: Please reference the MSL Tape Library QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs. | ||
|
|
||
| Disk-Based Backup | RDX Removable Disk Backup | |
| HP
StorageWorks RDX500 Internal Removable Disk Backup System NOTE: 500GB of Disk Storage. |
AJ934A | |
| D2D Backup | ||
| HP
StorageWorks D2D120 Backup System with Data Protector Express Software Kit NOTE: 2TB of Disk Storage. |
EH924A | |
| HP StorageWorks D2D130 Backup
System with LTO-3 Ultrium 920 SAS Tape Drive NOTE: 3TB of Disk Storage. |
EH952A | |
| HP
StorageWorks D2D2503i Backup System NOTE: 3TB of Disk Storage. |
EH945A | |
| HP
StorageWorks D2D4004i Backup System NOTE: 4.5TB of Disk Storage. |
EH938A | |
| NOTE: Please see the HP D2D Backup Systems QuickSpecs for additional information: http://www.hp.com/go/d2d. | ||
| | ||
| StorageWorks Options | StorageWorks Fibre Channel HBA
NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows and Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html |
|
| Brocade Fibre Channel HBAs | ||
| HP StorageWorks 81B PCI-e FC HBA Single Port |
AP769A
|
|
| HP StorageWorks 82B PCI-e FC HBA Dual Port | AP770A | |
| HP StorageWorks 41B 4Gb PCI-e FC HBA | AP767A | |
| HP StorageWorks 42B 4Gb Dual-Port PCI-e FC HBA | AP768A | |
| Emulex Fibre Channel HBAs | ||
| HP StorageWorks 81E PCI-e FC HBA Single Port | AJ762A | |
| HP StorageWorks 82E PCI-e FC HBA Dual Port | AJ763A | |
| HP StorageWorks FC2142 4Gb PCI-e HBA | A8002A | |
| HP StorageWorks FC2242 Dual Channel 4Gb PCI-e HBA | A8003A | |
| QLogic Fibre Channel HBAs | ||
| HP StorageWorks 81Q PCI-e FC HBA Single Port | AK344A | |
| HP StorageWorks 82Q PCI-e FC HBA Dual Port | AJ764A | |
| HP StorageWorks FC1142 4Gb PCI-e HBA | AE311A | |
| HP StorageWorks FC1242 Dual Channel 4Gb PCI-e HBA | AE312A | |
|
|
||
|
HP StorageWorks Modular Smart Array |
MSA SAN Storage Arrays | |
| HP StorageWorks 50 Modular Smart Array | 364430-B21 | |
| NOTE: Please see the Modular Smart Array 50 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/12245_na/12245_na.html | ||
| HP StorageWorks 60 Modular Smart Array | 418408-B21 | |
| NOTE: Please see the Modular Smart Array 60 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/12627_na/12627_na.html | ||
| HP StorageWorks 70 Modular Smart Array | 418800-B21 | |
| NOTE: Please see the Modular Smart Array 70 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/12652_na/12652_na.html | ||
| | ||
|
Uninterruptible Power Systems |
HP Tower UPS | |
| HP T1500 G3 UPS Models | ||
| HP T1500 G3 UPS | AF450A | |
| NOTE: Please see
the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13160_na/13160_na.html |
||
| HP Rack-mountable UPS | ||
| HP R1500 G2 UPS | ||
| HP, R1.5kVA UPS, 1U | AF419A | |
| NOTE: Please see
the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/12507_na/12507_na.html |
||
| HP R3000 UPS | ||
| HP R3000 VA UPS, 2U, Low Voltage L5-30 | AF422A | |
| HP R3000 VA UPS, 2U, High Voltage L6-20 | AF423A | |
| NOTE: Please see
the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/10671_na/10671_na.html |
||
| HP R/T3000 Uninterruptible Power System (UPS) | ||
| HP R/T3000 UPS, Low voltage | AF452A | |
| HP R/T3000 UPS, High voltage | AF453A | |
| NOTE: Please see
the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13417_na/13417_na.html |
||
| HP Rack-Mountable R5500 UPS | ||
| HP R5500 VA UPS | AF426A | |
| NOTE: Please see
the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/11871_na/11871_na.html |
||
| NOTE: For additional information on HP Uninterruptible Power Systems please go to: www.hp.com/servers/rackups. | ||
|
|
||
|
Power Distribution Units |
Monitored PDUs | |
| HP Monitored Power Distribution Unit: Full Rack Version | ||
| HP 17.3 kVA S2324 Monitored PDU- dual input, 3Ø, 24A |
AF503A
|
|
| HP 8.6 kVA S1324 Monitored PDU- single input, 3Ø, 24A |
AF504A
|
|
| HP 16.6 kVA S2140 Monitored PDU- dual input, 1Ø, 40A |
AF505A
|
|
| HP 8.3 S1140 Monitored PDU- single input, 1Ø, 40A |
AF506A
|
|
| HP Monitored Power Distribution Unit: Half Rack Version | ||
| HP 4.9 kVA S124 Monitored PDU- single input, 1Ø, 24A |
AF914A
|
|
| Modular Power Distribution Units 1U/0U (Up to 32 outlets) | ||
| HP Two Fixed Cord Extension Bars NOTE: Two extension bar sticks; each with (7) C13 plugs. |
351655-B21 | |
| 2.8 kVA Modular PDU, 24A | 252663-D71 | |
| 3.6 kVA Modular PDU, 16A | 252663-B24 | |
| 4.9 kVA Modular PDU, 24A | 252663-D72 | |
| 8.3 kVA Modular PDU, 40A | 252663-B21 | |
| 8.3 kVA Modular PDU, 40A | 252663-D73 | |
| 8.3 kVA Modular PDU, 40A | 252663-D75 | |
| 4.9 kVA Modular PDU, 24A | 252663-D74 | |
| NOTE: For additional information on HP Power Distribution Units including accessories please go to: www.hp.com/go/pdu (Worldwide) | ||
|
|
||
| HP Rack Series | HP Rack 5000 Series (Graphite Metallic) | |
| HP 5642 Rack-Unassembled | 358254-B21 | |
| NOTE: Please see
the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.html |
||
| HP Rack 10000 G2 Series (Carbon/Graphite Metallic) | ||
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Shock Pallet | AF034A | |
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Pallet | AF038A | |
| 10647 G2 (47U) Rack Cabinet 1200mm
Deep - Shock Pallet NOTE: Due to handling and shipping requirements, AF044A is only orderable through HP Factory Express. It is not for direct sales. Customer site surveys are required before an order is approved. CTO orders may require additional lead time. |
AF044A | |
| 10647 G2 (47U) Rack Cabinet 1200mm Deep - Pallet | AF045A | |
| NOTE: It is mandatory
to use a shock pallet when shipping racks with equipment installed. NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. |
||
|
|
||
| HP Rack Options | Monitors and keyboards | |
| TFT7600 Rackmount Keyboard Monitor |
AG052A
|
|
| HP TAA TFT7600 Rkmntkybd 17in Monitor | AG067A | |
| 1U Rackmount Keyboard with USB |
AG072A
|
|
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| HP KVM Switch Options | ||
| 2x1x16 IP Console Switch with Virtual Media | AF601A | |
| 4x1x16 IP Console Switch with Virtual Media | AF602A | |
| 1x1Ex8 KVM IP Console Switch G2 with Virtual Media and CAC | AF620A | |
| 2x1Ex16 KVM IP Console Switch G2 with Virtual Media and CAC | AF621A | |
| 4x1Ex32 KVM IP Console Switch G2 with Virtual Media and CAC | AF622A | |
| 2x16 Server Console Switch with Virtual Media | AF600A | |
| 0x2x16 KVM Server Console G2 Switch with Virtual Media and CAC | AF618A | |
| 0x2x32 KVM Server Console G2 Switch with Virtual Media and CAC | AF619A | |
| PS/2 Virtual Media Interface Adapter,
1 pack NOTE: Requires PS/2 and one USB port on server. |
AF604A | |
| Server console switch 0x2x8 | AF616A | |
| Server console switch 0x2x16 | AF617A | |
| HP TAA Server console switch 0x2x16 | AF626A | |
| PS/2 Interface Adapter, 1 pack | 262588-B21 | |
| PS/2 Interface Adapter, 8 pack | 262587-B21 | |
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x4 Console Switch | AF611A | |
| PS2 Server Console Cable, 6 ft, 2 pack | AF612A | |
| HP 1x4 KVM Console 6ft USB Cable | AF613A | |
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
| HP Serial Console Server Options | ||
| HP 16 Port Serial Console Server | AF101A | |
| HP 48 Port Serial Console Server | AF102A | |
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack | AF103A | |
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack | AF110A | |
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
| Rack Kits | ||
| HP ML370G6 Tower to Rack Conversion Kit | 515031-B21 | |
|
|
||
| USB and SD Options | HP 1.44MB USB External Floppy Drive |
DC141B
|
| HP USB 2-Button Optical Scroll Mouse |
DC172B
|
|
| HP Standard USB Keyboard US |
DT528A#ABA
|
|
| HP 4GB SD Flash Media Kit NOTE: Blank USB and SD media device is supported for use withVMware and Citrix. USB/SD media must be installed in the internal slot of the ProLiant server. Learn more at: http://www.hp.com/go/proliantvirtualization. |
580387-B21 | |
|
|
||
| Service
and Support Offerings (HP Care Pack Services) |
HP ProLiant ML370 G6 Service & Support Offerings | |
| Hardware Services On-site Service | ||
| 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic | U4528E | |
| 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic | U4529E | |
| Hardware Services 6-Hour Call to Repair On-site Service | ||
| 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic | U4530E | |
| Installation & Start-up Services | ||
| Hardware Installation, Electronic | U4538E | |
| Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays, Electronic | U4539E | |
| Support Plus | ||
| Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic | U4540E | |
| Support Plus 24 | ||
| Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic | U4541E | |
| Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic | U6311E | |
| Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic | U8333E | |
| HP ProLiant DL370 G6 Service & Support Offerings | ||
| Hardware Services On-site Service | ||
| 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic | UM752E | |
| 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic | UM753E | |
| Hardware Services 6-Hour Call to Repair On-site Service | ||
| 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic | UM754E | |
| Installation & Start-up Services | ||
| Hardware Installation, Electronic | UM777E | |
| Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays, Electronic | UM778E | |
| Support Plus | ||
| Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic | This service level no longer being offered | |
| Support Plus 24 | ||
| Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic | UM763E | |
| Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic | UM764E | |
| Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic | UM765E | |
| NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack. |
|
|
Memory
|
NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
| HP
ProLiant DL370 G6 Models HP ProLiant ML370 G6 Models |
| DDR3
memory population guidelines For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator Some
DIMM installation guidelines are summarized below:
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| NOTES:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
DIMM slot and configuration diagrams
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory configuration (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory plus optional memory (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory replaced
with optional memory (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| UDIMM maximum configuration (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory replaced
with optional memory (2 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| UDIMM maximum configuration (2 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| NOTE: Capacity references are rounded to the common Gigabyte values.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Following are memory options available from HP: | ||
| Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit | 500656-B21 | |
| HP 4GB 2Rx4 PC3-10600R-9 Kit | 500658-B21 | |
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit | 500660-B21 | |
| HP 8GB 2Rx4 PC3-8500R-7 Kit | 516423-B21 | |
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| HP 16GB 4Rx4 PC3-8500R-7 Kit | 500666-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient. |
||
|
|
Storage
![]() |
A | Removable media bay |
| B | SATA DVD-ROM Drive (Standard in all BTO Models) | |
| C | Optical Drive (blank) | |
| 1-8 |
Eight SFF SAS/SATA HDD Bays (Standard in all BTO Models) | |
![]() | A | Removable media bay |
| B | SATA DVD-ROM Drive (Standard in all BTO Models) | |
| C | Optical Drive (blank) | |
| 1-8 | Eight SFF SAS/SATA HDD Bays (Standard in all BTO Models) |
![]() | 1-24 | Twenty-four small form factor (SFF) hot-plug drive bays to support Serial-attached SCSI (SAS) and Serial ATA (SATA) drives with optional drive cages (up to three 8 SFF drive cage can be installed) |
![]() | 1-14 | Fourteen large form factor (LFF) hot-plug drive bays to support Serial-attached SCSI (SAS) and Serial ATA (SATA) drives with optional drive cages |
| Drive Support | |||
|
| |||
|
Quantity |
Position |
Controller | |
|
Removable Media | |||
| Half-Height SATA DVD-ROM Optical
Drive | Up
to 2 | A,
B | Integrated IDE |
| Half-Height
SATA DVD RW Optical Drive | Up
to 2 | A,
B | Integrated IDE |
| HP Slim SATA DVD-ROM Optical Drive | 1 NOTE: Also please use if the 3 drive cage is populated |
C | Integrated IDE |
| HP Slim SATA DVD RW Optical Drive | 1 NOTE: Also please use if the 3 drive cage is populated |
C | Integrated IDE |
| | |||
| Hard Drives NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. |
|||
| SAS Hot Plug SFF Enterprise (ENT) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 300GB 6G SAS 10K DP 300GB 3G
SAS 10K DP 146GB 6G SAS 15K DP 146GB 3G SAS 15K DP 146GB 6G SAS 10K DP 146GB 3G SAS 10K DP 72GB 6G SAS 15K DP 72GB 3G SAS 15K DP 72GB 3G SAS 10K DP |
Up to 24
|
1-8
1-24 |
HP Smart Array P800/512 BBWC
Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
| SAS Hot Plug 3.5" Enterprise (ENT) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 600GB 6G SAS 15K DP 450GB 6G SAS 15K DP 450GB 3G SAS 15K DP 300GB 6G SAS 15K DP 300GB 3G SAS 15K DP 146GB 3G SAS 15K DP |
Up to 14 | 1-14 | HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
| SAS Hot Plug SFF Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 500GB 6G SAS 7.2K DP | Up to 14 | 1-14 | HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
| SAS Hot Plug 3.5" Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 1TB 3G SAS 7.2K DP 750GB 3G SAS 7.2K DP |
Up to 14 | 1-14 | HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
| SATA Hot Plug SFF Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 500GB 3G SATA 7.2K 160GB 3G SATA 7.2K |
Up to 24 | 1-8 1-24 |
HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
| SATA Hot Plug 3.5" Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 1TB 3G SATA 7.2K 750GB 3G SATA 7.2K 500GB 3G SATA 7.2K 250GB 3G SATA 7.2K |
Up to 14 | 1-14 | HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
| SATA Hot Plug SFF Entry (ETY) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 250GB 3G SATA 5.4K 120GB 1.5G SATA 5.4K |
Up to 24
|
1-8
1-24 |
HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
| SATA Hot Plug 3.5" Entry (ETY) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 160GB 3G SATA 7.2K |
Up to 14
|
1-14
|
HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
| SATA Hot Plug Midline (MDL) Solid State Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 60GB 3.0G SATA SSD 120GB 3.0G SATA SSD |
Up to 24
|
1-8
1-24 |
HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
| SATA Hot Plug 3.5" Midline (MDL) Solid State Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 60GB 3.0G SATA SSD 120GB 3.0G SATA SSD |
Up to 14
|
1-14
|
HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
|
External Storage | |||
| Quantity |
Position |
Host Controller or Adapter | |
| 50 Modular Smart Array | Up to 4 | External | HP Smart Array P800/512 BBWC Controller |
| 60 Modular Smart Array | Up to 4 | External | HP
Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller |
| Up
to 8 | HP Smart Array P411/256
MB Controller HP Smart Array P411/512 MB BBWC Controller HP Smart Array P800/512 BBWC Controller | ||
| 70 Modular Smart Array |
Up to 2 |
External | HP
Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller |
| Up
to 4 | HP Smart Array P800/512
BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller | ||
|
| |||
| Tape and Disk-Based Backup | |||
| NOTE: For a complete listing of compatible tape and disk-based backup offerings, please visit: www.hp.com/go/connect. |
|
Position Supported |
Controller |
Part Number | |
| Internal
USB Tape Drives DAT 40 USB DAT 72 USB DAT 160 USB |
A | USB 2.0 Port | N/A |
| USB Tape Drives, External DAT 40 USB DAT 72 USB DAT 160 USB 1U Rack-Mount Kit |
External | USB 2.0 Port | N/A |
| SAS
Tape Drives, Internal DAT 160 SAS LTO-2 Ultrium 448 SAS LTO-3 Ultrium 920 SAS LTO-4 Ultrium 1760 SAS |
A | HP Smart Array P212/Zero Memory Controller |
462828-B21 |
| SAS Tape Drives, External
DAT 160 SAS LTO-2 Ultrium 448 SAS LTO-3 Ultrium 920 SAS LTO-4 Ultrium 1760 SAS LTO-4 Ultrium 1840 SAS 1U Rack-Mount 3U Rack-Mount |
External | HP Smart Array P212/Zero Memory Controller |
462828-B21 |
| SAS
Tape Automation, External 1/8 G2 Autoloader MSL2024 MSL4048 MSL8096 |
External | HP Smart Array P212/Zero Memory Controller |
462828-B21 |
| Fibre
Tape Automation, External MSL2024 MSL4048 MSL8096 MSL6000 |
External | Please consult the EBS connectivity matrix at: http://www.hp.com/go/ebs for detailed connectivity information. |
N/A |
| HP
StorageWorks RDX Removable Disk Backup System, Internal RDX160 RDX320 RDX500 | A | USB 2.0 Port | N/A |
| HP StorageWorks RDX Removable
Disk Backup System, External RDX160 RDX320 RDX500 | External | USB 2.0 Port | N/A |
| HP StorageWorks D2D Backup Systems
D2D120 D2D130 D2D2500i D2D4000i |
External | Embedded Network Controller |
N/A |
|
|
Power Specifications
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| To review typical
system power ratings use the Active Answers HP Power Advisor which is available
via the online tool located at URL: www.hp.com/go/proliant-energy-efficient
or www.hp.com/go/hppoweradvisor
|
|
|
Technical Specifications
| System Unit | Tower Dimensions
(H x W x D) (with bezel) | 18.52 x 9.75 x 29.12 in (47.04 x 24.77 x 73..96 cm) | |
| Rack
Dimensions (H x W x D) (with bezel) | 6.88 x 19.03 x 27.53 in (17.48 x 48.34 x 69.93 cm) | ||
|
Tower Weight (approximate)
| Maximum (two hard drives, power supply, and processor installed) | 103.06 lbs (46.75 kg) | |
| Minimum
(one hard drive, power supply, and processor installed) | 66,14 lbs (30.00 kg) | ||
Rack
Weight | Maximum (two hard drives, power supply, and processor installed) | 103.06 lbs (46,75 kg) | |
| Minimum
(one hard drive, power supply, and processor installed) | 55.12 lbs (25.00 kg) | ||
|
Input Requirements (per power supply) | Rated Line Voltage | 90 - 132 VAC,
180 - 264 VAC | |
| Rated Input Current | 7.5A (at 100 VAC),
3.8A (at 200 VAC) | ||
| Rated Input Frequency | 47 to 63 Hz | ||
| Rated Input Power | 980W
(at 100 VAC) 1035W (at 120 VAC) 1170W (at 240 VAC) | ||
| BTU Rating | Maximum |
460W - 1773 BTU / hr (at 120 VAC), 1715 (at 240 VAC) 750W - 2892 BTU / hr (at 120 VAC), 2797 (at 240 VAC) 1200W - 3530 BTU / hr (at 120 VAC), 4600 (at 240 VAC) | |
| Power Specifications | To review typical system power ratings use the HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient - Click on the system of interest. Example: DL370 G6 or ML370 G6 | ||
| Power
Supply Output (per power supply) | Rated Steady-State Power | 460 W (at 100 VAC) | |
| Maximum Peak Power | 460
W (at 200 VAC) 460 W (at 100 VAC) 460 W (at 200 VAC) NOTE: See Power Supply Specifications tables for complete details on 460W PSU and optional 750W and 1200W Power Supply Options. | ||
| System Inlet Temperature | Operating | 10°
to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C
per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of
3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the type and number of options
installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). | |
| Non-operating | -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). | ||
| Relative
Humidity (non-condensing) | Operating | 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. | |
| Non-operating | 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. | ||
| Altitude | Operating | 3048 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | |
| Non-operating | 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | ||
| Acoustic Noise | Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). | ||
| Idle | |||
| L WAd | 5.6 B for 1P Non-Redundant; 5.5 B for 2P Redundant | ||
|
L pAm | 39 dB for 1P Non-Redundant; 39 dB for 2P Redundant | ||
|
Operating | |||
| L WAd | 5.6 B for 1P Non-Redundant; 5.5 B for 2P Redundant | ||
|
L pAm | 39 dB for 1P Non-Redundant; 39 dB for 2P Redundant | ||
| NOTE: The Listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels. | |||
| Emissions Classification (EMC) | FCC Rating | Class B | |
| Normative Standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 | ||
| NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements. | |||
|
| |||
|
Smart Array P410i Controller |
Dimensions (not including bracket) |
Low Profile PCIe Form Factor 7.5 in x 9.5 in x 2.25 in (19.05 cm x 24.13 cm x 5.72 cm) |
| Disk Drive and Enclosure Interface - Transfer rate | 6Gb/s SAS (Serial Attached SCSI) | |
| 3Gb/s SATA (Serial ATA) | ||
| SAS Connectors | 2 internal (Mini-SAS) x8 wide port connectors | |
| Cache Memory Speed | DDR2-800MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s maximum bandwidth. | |
| Server Interface | x8 5G PCIe 2.0 provides 4GB/s maximum bandwidth | |
| SAS Speed | x8 3G SAS provides 2.4GB/s maximum bandwidth | |
| Cache Memory | 40-bit 256MB ECC protected cache (72-bit 512MB BBWC module upgrades available); transportable with battery-backed upgrade | |
| Logical Drives Supported | Up to 64 logical drives | |
| Maximum Logical Drive Capacity | Greater than 2TB | |
| Host Memory Addressing | 64-bit, supporting greater than 4GB server memory space | |
| RAID Support | RAID 6, 6+0 (Advanced Data Guarding) NOTE: The minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade is required to enable RAID 6, 6+0 |
|
| RAID 5, 5+0 (Distributed Data
Guarding) NOTE: The 256MB upgrade is required to enable RAID 5 support on the Smart Array P410i. |
||
| RAID 1+0 (Striping & Mirroring) | ||
| RAID 0 (Striping) | ||
| Upgradeable Firmware | Upgradeable Firmware with recovery ROM feature | |
|
|
||
| NC375i Integrated Quad Port Multifunction Gigabit Server Adapter | Network Interface | 10Base-T/100Base-TX/1000Base-TX | |
| Compatibility | IEEE
802.3 10Base-T IEEE 802.3ab 1000Base-T IEEE 802.3u 100Base-TX IEEE 802.3ad 1000Base-TX IEEE 802.1p 100Base-TX IEEE 802.1q 100Base-TX | ||
| Data Transfer Method | PCI Express, four lanes (x4) | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000 Mb/s | ||
| Connector | RJ-45 | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP up to 328 ft (100 m) | |
| 100Base-TX | Category 5 or higher UTP; up to 328 ft (100 m) | ||
| 1000Base-TX | Category 5 or higher UTP; up to 328 ft (100 m) | ||
|
| |||
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go
to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will
be recycled, recovered or disposed of in a responsible manner. |
| | ||
|
© Copyright 2009 Hewlett-Packard Development Company,
L.P. |