 Overview      Standard Features      HPC Interconnects      Models      Smart Buys      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Overview

HP ProLiant DL370 Generation 6 (G6)
HP ProLiant ML370 Generation 6 (G6)

 
HP ProLiant DL370 G6 (Rack)
Front View:Rear View:
1.Quick removal access panel1.Mouse connector
2.Three Hot-plug fans (standard) Five (optional)2.Keyboard connector
3.Intel Quad-Core Processor (Performance model includes two processors)3.Serial connector
4.iLO 2 connector
4.Eighteen slots for DDR3 Registered or Unbuffered Memory5.Two USB connectors
5.SAS/SATA drive cage6.9 Available PCI-Express Gen2 expansion slots; PCI-X (optional)
6.

Optional drive cage bay

7.PCI-X Expansion slot riser bay
7.Power on/standby button8.Four NIC connectors
8.System Insight Display9.Video connector
9.Removal media bay10.Power supply bay 2
10.DVD-ROM drive11.Power supply bay 1 (populated)
11.Optional slimline optical drive bay  
12.9 Available PCI-Express Gen2 slots; PCI-X (optional)  

HP ProLiant ML370 G6 (Tower)
Front View: Rear View:
1. 9 Available PCI-Express Gen2 slots; PCI-X (optional) 1. PCI-X Expansion slot riser bay
2. Quick removal access panel 2. Four NIC connectors
3. Three Hot-plug fans (standard) Five (optional) 3. Video connector
4. Intel Quad-Core Processor (Performance model includes two processors) 4. Power supply bay 2
5. Power on/standby button 5. Power supply bay 1 (populated)
6.

Optional drive cage bay

6. Mouse connector
7. SAS/SATA drive cage 7. Keyboard connector
8. System Insight Display 8. Serial connector
9. Optional slimline optical drive bay 9. Two USB connectors
10. DVD-ROM drive 10. iLO 2 connector
11. Removal media bay 11. 9 Available PCI-Express Gen2 expansion slots; PCI-X (optional)
12. Eighteen slots for DDR3 Registered or Unbuffered Memory

What's New

Announcing support for:

  • HP 16GB 4Rx4 PC3-8500R-7 Kit

At A Glance

The next generation of the HP ProLiant ML370 (expandable tower chassis) and the new HP ProLiant DL370 (4U rack optimized chassis) deliver Industry-leading management tools, leading performance, expandability, flexibility and the latest energy efficient technologies. These servers are well-suited for deployment in growing businesses, remote office sites, or datacenters and have been designed to bring you (our customer) the utmost confidence to run your business.

Features included in both the HP ProLiant ML370 G6 and the HP ProLiant DL370 G6:

  • Processors:
    • Up to two (2) Intel® Xeon® 5500 series processors series with Intel Turbo Boost technology which now allows customized adaptability for optimizing both power consumption and performance based on your respective requirements
    • Intel® 5520 chipset
  • Memory:
    • 18 DIMM slots
    • Up to 192GB, using PC3-8500R DDR3 Registered (RDIMM) memory, operating at 800MHz when fully populated at 2 DIMMs per Channel in 12 slots
    • Up to 24GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fully populated at 2 DIMMs per Channel in 12 slots
    • Two DIMMs Per Channel at 1333MHz supported with ROM update via ROM Based Setup Utility (RBSU) for 1333MHz RDIMMs. UDIMM support is only on 12-slot servers.
  • Storage Controller:
    • Entry Models: HP Smart Array P410i/256 MB Controller (RAID 0/1/1+0/5/5+0)
      NOTE: Entry Models available for ML370 G6 models only.
    • Base Models: HP Smart Array P410i/256 MB Controller (RAID 0/1/1+0/5/5+0)
    • Performance Models: HP Smart Array P410i/512 MB BBWC Controller (RAID 0/1/1+0/5/5+0)
    • Available upgrades: 256MB, 512MB with BBWC, Battery kit upgrade (for BBWC), and Smart Array Advanced Pack (SAAP)
  • Internal Drive Support:
    • Up to 24 small form factor (SFF) or 14 large form factor (LFF) hot-plug drive bays to support Serial-attached SCSI (SAS) and Serial ATA (SATA) drives
    • Standard half-height DVD-ROM (all models)
    • Two open half-height media bays available for tape drives, optical media, optional SAS HDD cage
  • Network Controller:
    • HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
  • Expansion Slots:
    • Nine (9) available PCI-Express Gen2 expansion slots to provide you with the latest I/O performance (see "Standard Features -Expansion Slots" section below for more details); PCI-X (optional)
  • Graphic Cards:
    • Supports up to 3 x 300W Graphic Cards via Graphic Card Power Adapter kit
      NOTE: 2 PCIe Gen2 x16 (mechanical/electrical); 1 PCIe Gen2 x16 (mechanical) x8 (electrical)
  • Ports:
    • USB 2.0 support
    • 6 total ports: (2) ports in front; (2) ports in rear; (1) port for internal key; (1) port for HP internal tape
    • 1 internal Secure Digital (SD) slot
  • Redundancy:
    • Multiple layers of fault tolerance through critical component redundancy (power supply and fan redundancy), mirrored memory, embedded RAID capability, and full-featured remote Lights-Out management
  • Power Sources:
    • Dual Common Slot Bay for Right Sized, Hot plug and Redundant Power options
      • HP 1200W CS HE Silver Power Supply (optional)
      • HP 750W CS HE Gold Power Supply (standard on some models)
      • HP 460W CS HE Gold Power Supply (standard on some models)
  • Infrastructure Management:
    • HP ProLiant Onboard Administrator (powered by the HP Integrated Lights-Out 2 management processor) for simplified server setup, health monitoring and recovery, power and thermal control, and lights-out remote administration.
    • HP Insight Control a product option, delivers essential infrastructure management that can help save time and money by making it easy to deploy, migrate, monitor, control and optimize your IT infrastructure through a single, simple management console. Insight Control supports both Windows and Linux-based central management servers.
    • HP Insight Dynamics for ProLiant, a product option, is an integrated command center that enables IT Staff personnel to continuously analyze and optimize a converged infrastructure, while automating and reducing the cost of common data center tasks by as much as 40 percent. This ultimately enables them to dynamically keep pace with the organization's changing business requirements.
  • Form Factor:
    • 4U Tower Chassis and 4U Rack Optimized Chassis
      • Redesigned 4U Tower Chassis and the new 4U Rack Optimized Chassis to better meet our customer's density requirements
  • Operating Systems and Virtualization Software Support for ProLiant Servers:
    • Supports Windows, RHEL, SLES, OEL, Solaris, VMware, and Citrix Essentials for XenServer
  • Deployment/Serviceability:
    • System Insight Display on the front bezel for quick and easy server diagnostics
    • Quick Deploy Rail System includes sliding universal rails, an ambidextrous cable management arm and quick release levers for fast and easy serviceability
    • Tool-less access to all system components for easy in rack serviceability
    • Customer Self Repair (CSR): HP products are designed with many CSR parts to minimize repair time and allow for greater flexibility in performing defective parts replacement
  • Warranty:
    • This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners resellers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.
      NOTE: Server Warranty includes 3-Year Parts, 3-Year Labor, 3-Year Onsite support with next business day response. Warranty repairs may be accomplished through the use of Customer Self Repair (CSR) parts. These parts fall into two categories: 1) Mandatory CSR parts are designed for easy replacement. A travel and labor charge will result when customers decline to replace a Mandatory CSR part; 2) Optional CSR parts are also designed for easy replacement but may involve added complexity. Customers may choose to have HP replace Optional CSR parts at no charge. Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html

contents
 Overview      Standard Features      HPC Interconnects      Models      Smart Buys      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Standard Features

NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section.
Processor
One of the following depending on Model
Quad-Core Processors
Intel® Xeon® Processor W5580 (3.20 GHz, 8MB L3 Cache, 130W, DDR3-1333, HT, Turbo 1/1/1/2)
Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3)
Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3)
Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3)
Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800)
Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)
Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2)
Dual-Core Processors
Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800)
NOTE: Up to 2 processors supported. Performance configurations include two processors. Mixing different processor models is not supported.
NOTE: HT indicates that the processor model supports Intel® Hyper-Threading Technology.
NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage.

Cache Memory
One of the following depending on Model
8MB (1 x 8MB) Level 3 cache
NOTE: All processor models except for those identified below.
4MB (1 x 4MB) Level 3 cache
NOTE: For processors E5506/E5504/E5502.

UpgradeabilityUpgradeable to two processors

ChipsetIntel® 5520 chipset
NOTE: For more information regarding Intel chipsets, please see the following URL:
http://www.intel.com/products/server/chipsets/.

Memory ProtectionAdvanced ECC
Mirroring mode
Lockstep mode

Memory
One of the following depending on Model
TypeDDR3 Registered (RDIMM) or Unbuffered (UDIMM)
Standard (Performance Models)12 GB (6 x 2 GB) RDIMM
Standard (Base Models) 6 GB (3 x 2 GB) RDIMM
Standard (Entry Model) 4 GB (2 x 2 GB) RDIMM
Maximum (RDIMM) 192 GB (12 x 16 GB) for Registered Memory configurations
Maximum (UDIMM)24 GB (12 x 2 GB) for Unbuffered Memory configurations
NOTE: Depending on the memory configuration and processor model, the memory speed may run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration Tool at: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient.
DDR3 memory options part number decoder

Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter

Expansion Slots
Expansion Slots #
Technology
Bus Width
Connector Width
Form Factor
Notes
1
PCIe
x4
x8
Half length, full height
2PCIe2x4
x8
Full Length/Full Height
 
3
PCIe2
x16
x16
Full Length/Full Height
4
PCIe2
x4
x8
Full Length/Full Height
 
5PCIe2
x4
x8
Full Length/Full Height
 
6
PCIe2
x8
x16
Full Length/Full Height
 
7
PCIe2
x4
x8Full Length/Full Height
 
8PCIe2x16
x16
Full Length/Full Height
 
9
PCIe2
x4x8
Full Length/Full Height
 

10

PCIe2X8X8Half length, full heightUtilized by NIC controller "Use the correct model number for the NIC"
11PCI-X See note See note Full Length/Full Height (optional) *Up to
64bits/133Mhz speed when only one device install in slot 11 and 12
*up to
64bits/100Mhz speed when both slot 11 and 12 are utilized.
12PCI-X See note See note Full Length/Full Height(optional)
*Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number.

Storage Controller
One of the following depending on Model
Entry ModelsHP Smart Array P410i/256 MB Controller (RAID 0/1/1+0/5/5+0)
Base ModelsHP Smart Array P410i/256 MB Controller (RAID 0/1/1+0/5/5+0)
Performance ModelsHP Smart Array P410i/512 MB BBWC Controller (RAID 0/1/1+0/5/5+0/6)
Available upgrades: 256MB, 512MB with BBWC, 512MB with FBWC, 1G with FBWC, Battery kit upgrade (for BBWC), and Smart Array Advanced Pack (SAAP).

StorageDiskette DriveNone Standard
Optical Drive SATA DVD ROM (standard in all models)
Hard DrivesNone Standard

Maximum Internal Storage TypeHot Plug SFF SAS
7.20TB
24 x 300GB
Hot Plug LFF SAS14 TB14 x 1TB

InterfacesSerial
1 (rear)
Pointing Device (Mouse)
1
VGA
1 (+1 front VGA on rack models)
Keyboard
1
Network RJ-45 (Ethernet)
4 (rear)
ILO 2.0 remote management port
1
SD slot1
USB 2.0 Ports5 (2 on the rear, 2 on the front, 1 internal)
NOTE: Please see the following URL for additional information regarding USB support:
http://h18004.www1.hp.com/products/servers/platforms/usb-support.html
Dedicated USB 2.0 Port1 (available for DAT USB tape connectivity)
NOTE: Internal USB ports are optimal for the attachment of HP DAT USB Internal Tape Drives

Graphics

Integrated ATI RN50, 64 MB video standard

  • 16 bit color: maximum resolution of 1600 x 1200
  • 32 bit color: maximum resolution of 1280 x 1024

NOTE: Maximum resolution available via iLO 2 remote console is 1280 x 1024.


Form Factor4U Rack and Tower form factor (7 in, 17.8 cm)

HP Insight management software HP Insight Foundation

Managing the growing number of servers can be complex and expensive for your organization. IT managers need to address changing business needs with tools that meet the challenges of managing today's complex Datacenters.

HP provides management solutions that are designed to simplify a server's installation, configuration and maintenance throughout the entire server lifecyle. This provides the customer with higher levels of operational efficiency and highly reliable systems: www.hp.com/go/foundation.
The foundation pack includes:

  • HP SmartStart
  • HP Management
  • HP ProLiant Firmware Maintenance

SmartStart version supported (minimum): SmartStart 8.20
http://www.hp.com/servers/smartstart

ProLiant Onboard Administrator

HP ProLiant Onboard Administrator (powered by the HP Integrated Lights-Out 2 management processor) simplifies server setup, health monitoring, power and thermal control, and lights-out remote administration of ProLiant ML, DL, and BL servers. HP ProLiant Onboard Administrator functions without additional software, and can be accessed from any location via a web browser. It works hand-in-hand with HP Systems Insight Manager, Insight Control suites, and the Insight Dynamics for ProLiant helping customers unlock the value of the ProLiant platform and deliver the highest possible quality of IT service to the business. See www.hp.com/go/ProLiantOA

HP Insight Control

HP Insight Control, a product option, delivers essential infrastructure management that can help save time and money by making it easy to deploy, migrate, monitor, remote control, and optimize your IT infrastructure through a single, simple management console.

Two versions of Insight Control are available, to serve environments requiring either a Linux-based or a Windows-based central management server: HP Insight Control for Linux, and HP Insight Control. See www.hp.com/go/insightcontrol

HP Insight Control includes one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/insight.

HP Insight Dynamics for ProLiant HP Insight Dynamics for ProLiant, a product option, is an integrated command center that enables IT Staff personnel to continuously analyze and optimize a converged infrastructure, while automating and reducing the cost of common data center tasks by as much as 40 percent. As a powerfully integrated by design toolkit to accelerate complex technology projects and simplify daily operations that ultimately enable IT Staff personnel to dynamically keep pace with the organizations changing business requirements. It enables them to plan capacity and power continuously, balance across physical and virtual resources, and ensure cost-effective high availability. It also enables IT organizations to provision infrastructure consistently and automatically from pools of shared resources using a self-service portal. Resources provisioned can range from a single virtual machine to complex multi-tier environments and their associated physical and virtual resource requirements. In addition to the previous functional benefits, it also provides a cost-effective disaster recovery for physical and virtual environments that works with HP StorageWorks Continuous Access software for both the Enterprise Virtual Array and the XP storage array allowing application environments to be reactivated in minutes with the touch of a button to a remote location.

NOTE: For more information, visit:
http://www.hp.com/go/insightdynamics

Industry Standard ComplianceACPI V2.0 Compliant
PCI-Express Gen2
PXE Support
WOL Support
Microsoft® Logo certifications
USB 2.0 Support
SMBIOS 2.6.1

Security Power-on password
Keyboard password
Diskette drive control
Diskette boot control
QuickLock, Network Server Mode
Serial interface control
Administrator's password

Security Trusted Platform Module

Trusted Platform Module option kit

The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to authenticate the server platform. These artifacts can include passwords, certificates and encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user data and to ensure that a server running Windows Server 2008 has not been tampered with while the system was offline. For more information about TPM, including a white paper, go to www.hp.com/go/TPM

NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment.
NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing the key could result in data loss.


Server Power CordsHigh voltage power cord ships standard with all part numbers.
NOTE: ProLiant DL servers no longer ship standard with NEMA power cords (187335-001) that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected to PDU's in data center racks so they now ship standard with only a PDU power cord (416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle (NEMA-15), the above NEMA power cord must be ordered separately.

UPS Power Cord Matrix Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Power Cords, click on the “HP Power Cord Matrix” link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords.

Power Supply
One of the following depending on Model
HP has a new design for ProLiant power- the new Common Slot Power Supply bay. This design provides the customer with commonality in power supplies across multiple platforms to save on the cost of spares and allows HP to offer multiple power solutions to fit the customers' needs. Many HP ProLiant Servers come with Common Slot, High Efficiency and Right-Size Power Supplies. The new HP Common Slot power supplies are designed for the highest power efficiency without degrading performance of the ProLiant server. Power Supplies have efficiency ratings up to 92%. There are three Right Size power options available depending on the configuration of your server. To make sure you select the correct power supply to meet your configuration, please use the HP Power Advisor at www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor. All HP Common Slot power sources are UL, CE Mark Compliant, Hot Plug and Redundant.

Common Slot ProLiant

It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for your needs. HP offers four Power Supply Options:

  • HP 460Watts, Common Slot, 92% Efficiency
  • HP 750Watts, Common Slot, 92% Efficiency
  • HP 1200Watts, Common Slot, 90% Efficiency

HP's ProLiant Common Slot Power supplies (460W & 750W) meet multiple Energy Efficiency Initiatives. Climate Savers Computing Initiative GOLD, ECOS Consulting 80PLUS GOLD and plans on offering models that meet the Energy Star for Server requirements when they are published.

HP's ProLiant Common Slot Power supplies (1200W) meet multiple Energy Efficiency Initiatives. Climate Savers Computing Initiative Bronze, ECOS Consulting 80PLUS Bronze Power Supply requirements.

Redundant Power: Optional (1+ 1 or n+n redundant) power supplies can be purchased through power supply option kits (see Redundant Options for part numbers).


System Fans (3) Hot Plug fans ship standard
NOTE: For full redundancy you can purchase the HP ML370 G6 and DL370 G6 Redundant Fan Kit; PN: 508107-B21.

Required CablingFor external storage cabling information, refer to the Web site at: www.hp.com/servers/dl370 or www.hp.com/servers/ml370.

Operating Systems and Virtualization Software Support for ProLiant Servers

Microsoft Windows Server
Microsoft Windows Server 2008 Hyper-V
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
Oracle Enterprise Linux (OEL)
Solaris
VMware
HP Citrix Essentials for XenServer

NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/ossupport and our driver download page http://www.hp.com/support/ML370G6.


Rack Airflow Requirements

Rack 10000 G2 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.

CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:

  • Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
  • Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm).

CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.

NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: www.hp.com/servers/ml370-g6.


Rack Kit

Quick deploy rail system provides tool-free support for racks with square or round mounting holes (including Compaq/HP 7000, 9000, 10000 G2 and HP series), with an adjustment range of 24" - 36". The ambidextrous cable management arm can be mounted on either the left or right side for improved cable management.


Telco Rack Support

Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions at: www.hp.com/go/rackandpower.


Factory Express Portfolio for Servers and Storage

HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed.

Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches.

For more information on Factory Express services for your specific server model please contact your sales representative or go to: http://www.hp.com/go/factory-express.


HP Enterprise Configurator The HP eConfigure Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. http://www.hp.com/products/configurator

Service and Support

HP Care Pack services provide total care and support expertise with committed response designed to meet your IT and business needs.

HP Care Pack services include coverage for the HP branded hardware options qualified for the server and purchased at the same time or afterward that are internal to the enclosure. This also includes the 22" and smaller external monitors and tower UPS options up to 3kVA. These items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, and standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack.

To fully capitalizing on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions, provides a range of support services designed to meet the varying needs of your business. Whether an SMB, or large global corporation, HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime.

Recommended Service
- simplify ProLiant solution implementation, maintenance, and management.

  • Support - 3-Year 4-Hour response 24x7 Same Business Day Coverage only
  • Service - Installation and Start up only

Enhanced Service - optimize service level to increase IT performance and availability.

  • Support - 3-Year Support Plus 24 only

Refer to the information on "Installation & Start-Up" for service on ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet; to be delivered on a scheduled basis 8am-5pm, M-F, excluding HP holidays.

NOTE: For a complete listing of service offerings and information visit:
http://www.hp.com/services/proliantservices
http://www.hp.com/go/proliant/carepack

contents
 Overview      Standard Features      HPC Interconnects      Models      Smart Buys      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

HPC Interconnects

NOTE: High Performance Computing (HPC) interconnect technologies are available for this server under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects: http://www.hp.com/techservers/clusters/ucp/index.html.

HPC Interconnect InfiniBand PCI-X and PCI-Express adapters
Gigabit Ethernet Use embedded ports
Myrinet XP PCI-X Rev D and Rev E adapters
contents
 Overview      Standard Features      HPC Interconnects      Models      Smart Buys      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Models

Base Models

HP ProLiant DL370 G6 E5530 2.40GHz Quad Core SFF Base Rack Server
487794-001
Processor (1) Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Cache Memory 8MB (1 x 8MB) L3 cache
Memory 6GB (3 x 2GB) PC3-10600 (DDR3-1333) Registered DIMMs
Network ControllerHP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Storage ControllerHP Smart Array P410i/256MB Controller
Hard DriveNone ship standard
Internal Storage(8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed)
Optical DriveSATA DVD ROM
PCI-Express Slots10 slots - (9) available PCI-e Gen2 slots (NOTE: 10 slots available, one is taken by the NIC riser card)
Power Supply(1) 750W Hot Plug Power Supply
Fans(3) Hot Plug Fans
Form Factor4U Rack

Performance Models

HP ProLiant DL370 G6 X5550 2.66GHz Quad Core SFF High Performance Rack Server
487790-001

Processor (2) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3)
Cache Memory 8MB (1 x 8MB) L3 cache
Memory 12GB (6 x 2GB) PC3-10600 (DDR3-1333) Registered DIMMs
Network ControllerHP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Storage ControllerHP Smart Array P410i/512MB with BBWC
Hard DriveNone ship standard
Internal Storage(8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed)
Optical DriveSATA DVD ROM
PCI-Express Slots10 slots - (9) available PCI-e Gen2 slots (NOTE: 10 slots available, one is taken by the NIC riser card)
Power Supply(2) 750W Redundant Hot Plug Power Supplies
Fans(5) Fully Redundant Hot Plug Fans
Form Factor4U Rack

HP ProLiant DL370 G6 X5550 2.66GHz Quad Core SFF Performance ICE Rack Server
576411-001

Processor (2) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3)
Cache Memory 8MB (1 x 8MB) L3 cache
Memory 12GB (6 x 2GB) PC3-10600 (DDR3-1333) Registered DIMMs
Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Storage Controller HP Smart Array P410i/512MB with BBWC
Manageability HP Insight Control Environment No Media single server license, including 1 year of 24x7 Technical Support and Updates
Hard Drive None ship standard
Internal Storage (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed)
Optical Drive SATA DVD ROM
PCI-Express Slots 10 slots - (9) available PCI-e Gen2 slots (NOTE: 10 slots available, one is taken by the NIC riser card)
Power Supply (2) 750W Redundant Hot Plug Power Supplies
Insight Control Environment (ICE) HP Insight Control Environment No Media single server license, including 1 year of 24x7 Technical Support and Updates
Fans (5) Fully Redundant Hot Plug Fans
Form Factor 4U Rack

Base Tower Models: Quad-Core

HP ProLiant ML370 G6 E5540 2.53GHz Quad Core SFF Base Tower Server
487791-001

Processor

(1) Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)

Cache Memory 8MB (1 x 8MB) L3 cache
Memory 6GB (3 x 2GB) PC3-10600 (DDR3-1333) Registered DIMMs
Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Storage ControllerHP Smart Array P410i/256MB Controller
Hard DriveNone ship standard
Internal Storage(8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed)
Optical DriveSATA DVD ROM
PCI-Express Slots10 slots - (9) available PCI-e Gen2 slots (NOTE: 10 slots available, one is taken by the NIC riser card)
Power Supply(1) 750W Hot Plug Power Supply
Fans(3) Hot Plug Fans
Form Factor4U Tower

Entry Tower Models: Quad-Core

HP ProLiant ML370 G6 E5520 2.26GHz Quad Core SFF Entry Tower Server
487795-001

Processor (1) Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Cache Memory 8MB (1 x 8MB) L3 cache
Memory 4 GB (2 x 2 GB) PC3-10600 (DDR3-1333) Registered DIMMs
Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Storage ControllerHP Smart Array P410i/256MB Controller
Hard DriveNone ship standard
Internal Storage(8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed)
Optical DriveSATA DVD ROM
PCI-Express Slots10 slots - (9) available PCI-e Gen2 slots (NOTE: 10 slots available, one is taken by the NIC riser card)
Power Supply(1) 460W Hot Plug Power Supply
Fans(3) Hot Plug Fans
Form Factor4U Tower
contents
 Overview      Standard Features      HPC Interconnects      Models      Smart Buys      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Smart Buys

The ProLiant Smart Buy program offers a collection of promotional server and option products that are configured with SMB in mind, offered at discounted prices, and positioned for quick delivery. Smart Buy server offers are available for a limited time only.

S-Buy ML370G6 E5530 6GB SFF
519578-005
Processor(s) (1) Intel® Xeon® Processor E5530 (2.40 GHz, 80 Watts, DDR3-1066)
Cache Memory 8MB Level 3 cache
Memory 6 GB (3x 2GB 2Rx8 PC3-10600R-9 Kit)
Network Controller NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Storage Controller Smart Array P410i/512MB BBWC
Hard Drive None included
Internal Storage Up to 8 SFF standard, up to 24 SFF with 2 additional drive cages
Optical Drive Half-Height SATA DVD-ROM Drive
Power Supply (2) HP 750-Watt CS HE Power Supply Kit
Fans 3 standard Hot Plug fans, 5 total Hot Plug fans supported (with addition of Redundant Fan Kit)
Form Factor 4U Tower

S-Buy DL370G6 E5540 8GB SFF
519577-005
Processor(s) (2) Intel® Xeon® Processor E5540 (2.53 GHz, 80 Watts, DDR3-1066)
Cache Memory 8MB Level 3 cache
Memory 8 GB (2x 4GB 2Rx4 PC3-10600R-9 Kit)
Network Controller NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Storage Controller Smart Array P410i/512MB BBWC
Hard Drive None included
Internal Storage Up to 8 SFF standard, up to 24 SFF with 2 additional drive cages
Optical Drive Half-Height SATA DVD-ROM Drive
Power Supply (2) HP 1200-Watt CS HE Power Supply Kit
Fans (5) Fully Redundant Hot Plug Fans (3 standard + Redundant Fan Kit)
Form Factor 4U Rack
contents
 Overview      Standard Features      HPC Interconnects      Models      Smart Buys      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Configuration Information - Factory Integrated Models

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO product offerings and requirements.
NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis.
NOTE: FIO indicates that this option only available as a Factory Installable Option.

Step 1: Base Configuration (choose one of the following configurable models)
ModelsHP ProLiant ML370 G6 Tower Models
HP ProLiant ML370 G6 SFF CTO Chassis
NOTE: Supports Small Form Factor (SFF) - 2.5" Drives
483880-B21
Factory Integrated Model ships with: 

HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Integrated Lights-Out embedded
HP Smart Array P410i/Zero Memory Controller
(8) Hot-Plug (SFF) SAS/SATA Drive Bays
(9) available PCI-e Gen2 slots
(5) USB ports
(3) Hot Plug Fans
Tower Form Factor

 
HP ProLiant ML370 G6 Tower CTO Chassis
 
HP ProLiant ML370 G6 LFF CTO Chassis
NOTE: Supports Large Form Factor (LFF) - 3.5" Drives
483879-B21
Factory Integrated Model ships with:
 
HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Integrated Lights-Out embedded
HP Smart Array P410i/Zero Memory Controller
(6) Hot-Plug (LFF) SAS/SATA Drive Bays
(9) available PCI-e Gen2 slots
(5) USB ports
(3) Hot Plug Fans
Tower Form Factor
 
HP ProLiant DL370 G6 Rack Models
 
HP ProLiant DL370 G6 SFF CTO Chassis
NOTE: Supports Small Form Factor (SFF) - 2.5" Drives

483874-B21

Factory Integrated Model ships with:
 
HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Integrated Lights-Out embedded
HP Smart Array P410i/Zero Memory Controller
(8) Hot-Plug (SFF) SAS/SATA Drive Bays
(9) available PCI-e Gen2 slots
(5) USB ports
(3) Hot Plug Fans
4U Rack Form Factor
 
HP ProLiant DL370 G6 LFF CTO Chassis
NOTE: Supports Large Form Factor (LFF) - 3.5" Drives
483873-B21
Factory Integrated Model ships with:
 
HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter
Integrated Lights-Out embedded
HP Smart Array P410i/Zero Memory Controller
(6) Hot-Plug (LFF) SAS/SATA Drive Bays
(9) available PCI-e Gen2 slots
(5) USB ports
(3) Hot Plug Fans
4U Rack Form Factor
 

Step 2: Choose Required Options (only one of the following from each list)
Processors NOTE: If High Performance Model features are desired, 2nd processor is included in the Performance Pack part numbers in Step 3 below.  
Quad-Core Processors
Intel® Xeon® Processor W5580 (3.20 GHz, 8MB L3 Cache, 130W, DDR3-1333, HT, Turbo 1/1/1/2), FIO 495928-L21
Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO 495930-L21
Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO
495932-L21
Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO
495934-L21
Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO
495936-L21
Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO
495938-L21
Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO
495940-L21
Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO 495942-L21
Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO
495944-L21
Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2), FIO 505511-L21
Dual-Core Processors
Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO 495946-L21
Base Memory Registered DIMMs (RDIMMs)
HP 2GB 2Rx8 PC3-10600R-9 Kit
500656-B21
HP 4GB 2Rx4 PC3-10600R-9 Kit
500658-B21
HP 4GB 4Rx8 PC3-8500R-7 LP Kit
500660-B21
HP 8GB 2Rx4 PC3-8500R-7 Kit 516423-B21
HP 8GB 2Rx4 PC3-10600R-9 Kit
500662-B21
HP 16GB 4Rx4 PC3-8500R-7 Kit 500666-B21
Unbuffered with ECC DIMMs (UDIMMs)
HP 1GB 1Rx8 PC3-10600E-9 Kit 500668-B21
HP 2GB 2Rx8 PC3-10600E-9 Kit 500670-B21
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient
 
Power Supply NOTE: Refer to HP Power Advisor when selecting a power supply for your configuration, www.hp.com/go/hppoweradvisor. Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor  
HP 460W CS HE Gold Power Supply 503296-B21
HP 750W CS HE Gold Power Supply 512327-B21
HP 1200W CS HE Silver Power Supply 500172-B21
NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables.  

Step 3: Choose Additional Factory Integratable Options
Controllers NOTE: If Additional Memory Cache Module or Controller is Required please pick one of the following:  
256MB Cache Module FIO
NOTE: Available for P410i only.
534108-B21
512MB BBWC 462967-B21
512MB Flash Backed Write Cache
NOTE: Supported on the Smart Array P410i Controller only.
534916-B21
1G Flash Backed Write Cache
NOTE: Supported on the Smart Array P410i Controller only.
534562-B21
HP Smart Array P212/256 MB w/ Battery FIO 491191-B21
HP Smart Array P410/256 MB w/ Battery FIO 491195-B21
HP Smart Array P411/256 MB w/ Battery FIO 491193-B21
Performance Packs Performance Packs are necessary to configure a HP ProLiant DL370 G6 or a HP ProLiant ML370 G6 to a High Performance Model which includes the latest performance technologies and enterprise class availability features pre-installed for convenience and value. The Performance Pack includes a 2nd processor, redundant fans, power supply, and memory expansion board.
NOTE: Must also select 447326-B21 to achieve parity to DL370 G6 or ML370 G6 High Performance Models.
 
HP ML370 G6 and DL370 G6 X5550 HPM FIO Perf Kit
516727-B21

Step 4: Choose Additional Options for Factory Integration
NOTE: For additional options, please refer to the "Core Options" and "Additional Options" section below.
contents
 Overview      Standard Features      HPC Interconnects      Models      Smart Buys      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Core Options

NOTE: Some options may not be available for factory integration. Please contact an HP sales representative for additional information.

Unique Options (8) Small Form Factor (SFF) 2nd Drive Cage Kit 507803-B21
(6) Large Form Factor (LFF) Backplane Kit 507810-B21
(2) Large Form Factor (LFF) Drive Cage Kit 487936-B21
HP ML370 G6 Tower to Rack Conversion Kit 515031-B21
HP ML370 G6 and DL370 G6 Redundant Fan Kit 508107-B21
HP ML370 G6 and DL 370 G6 Graphic Card Adapter Kit
NOTE: An option kit will be required per Graphic Card)
NOTE: 2 PCIe Gen2 x16 (mechanical/electrical); 1 PCIe Gen2 x16 (mechanical) x8 (electrical)
537721-B21
HP ML370 G6 and DL370 G6 Smart-mini DIMM Module
NOTE: By plugging the Smart-mini DIMM Module to the HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter, TCP/IP Offload Engine (TOE) for Windows is enabled/supported.
519808-B21
HP ML370 G6 and DL370 G6 PCI-X Riser Kit
NOTE: Customers purchasing the PCI-X Riser Kit, must also purchase the Redundant Fan kit (508107-B21)
516434-B21

Processors Quad-Core Processors  
Intel® Xeon® Processor W5580 (3.20 GHz, 8MB L3 Cache, 130W, DDR3-1333, HT, Turbo 1/1/1/2) 495928-B21
Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) 495930-B21
Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) 495932-B21
Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) 495934-B21
Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) 495936-B21
Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) 495938-B21
Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) 495940-B21
Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) 495942-B21
Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) 495944-B21
Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) 505511-B21
Dual-Core Processors  
Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) 495946-B21

Memory

Registered DIMMs (RDIMMs)
HP 2GB 2Rx8 PC3-10600R-9 Kit
500656-B21
HP 4GB 2Rx4 PC3-10600R-9 Kit
500658-B21
HP 4GB 4Rx8 PC3-8500R-7 LP Kit
500660-B21
HP 8GB 2Rx4 PC3-8500R-7 Kit 516423-B21
HP 8GB 2Rx4 PC3-10600R-9 Kit
500662-B21
HP 16GB 4Rx4 PC3-8500R-7 Kit 500666-B21
Unbuffered with ECC DIMMs (UDIMMs)  
HP 1GB 1Rx8 PC3-10600E-9 Kit 500668-B21
HP 2GB 2Rx8 PC3-10600E-9 Kit 500670-B21
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator
NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient
 

Optical Drives

HP Half-Height SATA DVD-ROM Optical Drive 447326-B21
HP Half-Height SATA DVD-RW Optical Drive 447328-B21
HP Slim SATA DVD-ROM Optical Drive481041-B21
HP Slim SATA DVD RW Optical Drive 481043-B21

Hard Drives NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.
 
SAS Hot Plug SFF Enterprise (ENT) Drives
HP 300GB 6G SAS 10K SFF DP ENT HDD
507127-B21
HP 300GB 3G SAS 10K SFF DP ENT HDD
492620-B21
HP 146GB 6G SAS 15K SFF DP ENT HDD 512547-B21
HP 146GB 3G SAS 15K SFF DP ENT HDD 504062-B21
HP 146GB 6G SAS 10K SFF DP ENT HDD 507125-B21
HP 146GB 3G SAS 10K SFF DP ENT HDD
418367-B21
HP 72GB 6G SAS 15K SFF DP ENT HDD
512545-B21
HP 72GB 3G SAS 15K SFF DP ENT HDD 418371-B21
HP 72GB 3G SAS 10K SFF DP ENT HDD
384842-B21
SAS Hot Plug 3.5" Enterprise (ENT) Drives  
HP 600GB 6G SAS 15K 3.5" DP ENT HDD 516828-B21
HP 450GB 6G SAS 15K 3.5" DP ENT HDD
516816-B21
HP 450GB 3G SAS 15K 3.5" DP ENT HDD 454232-B21
HP 300GB 6G SAS 15K 3.5" DP ENT HDD 516814-B21
HP 300GB 3G SAS 15K 3.5" DP ENT HDD 416127-B21
HP 146GB 3G SAS 15K 3.5" DP ENT HDD 384854-B21
SAS Hot Plug SFF Midline (MDL) Drives  
HP 500GB 6G SAS 7.2K SFF DP MDL HDD 507610-B21
SAS Hot Plug 3.5" Midline (MDL) Drives  
HP 1TB 3G SAS 7.2K 3.5" DP MDL HDD 461137-B21
HP 750GB 3G SAS 7.2K 3.5" DP MDL HDD 461135-B21
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12244_na/12244_na.html
 
SATA Hot Plug SFF Midline (MDL) Drives  
HP 500GB 3G SATA 7.2K 2.5in MDL HDD 507750-B21
HP 160GB 3G SATA 7.2K 2.5in MDL HDD 530888-B21
SATA Hot Plug 3.5" Midline (MDL) Drives  
HP 1TB 3G SATA 7.2K 3.5" MDL HDD 454146-B21
HP 750GB 3G SATA 7.2K 3.5" MDL HDD 458930-B21
HP 500GB 3G SATA 7.2K 3.5" MDL HDD 458928-B21
HP 250GB 3G SATA 7.2K 3.5" MDL HDD 458926-B21
SATA Hot Plug 3.5" Entry (ETY) Drives  
HP 160GB 3G SATA 7.2K 3.5" ETY HDD 458945-B21
SATA Hot Plug SFF Entry (ETY) Drives  
HP 250GB 3G SATA 5.4K SFF ETY HDD 460355-B21
HP 120GB 1.5G SATA 5.4K SFF ETY HDD 458924-B21
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13021_na/13021_na.html
 
SATA Hot Plug Midline (MDL) Solid State Drives  
HP 60GB 3G SATA 2.5in MDL 1y Wty SSD 572071-B21
HP 120GB 3G SATA 2.5in MDL 1y Wty SSD 572073-B21
SATA Hot Plug 3.5" Midline (MDL) Solid State Drives  
HP 60GB 3G SATA 3.5in MDL 1y Wty SSD 570761-B21
HP 120GB 3G SATA 3.5in MDL 1y Wty SSD 570763-B21
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13415_na/13415_na.html
 

Communications Networking  
Gigabit Ethernet adapters  
HP NC112T PCIe Gigabit Server Adapter
503746-B21
HP NC360T PCI Express Dual Port Gigabit Server Adapter
412648-B21
HP NC364T PCI Express Quad Port Gigabit Server Adapter
NOTE: There is a maximum of five NC364T PCI Express Quad Port Gigabit Server Adapters allowed in this server.
435508-B21
HP NC373F PCI Express Multifunction Gigabit Server Adapter
394793-B21
HP NC373T PCI Express Multifunction Gigabit Server Adapter
394791-B21
HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter
458492-B21
HP NC375T PCI Express Quad Port Gigabit Server Adapter 538696-B21
10 Gigabit Ethernet adapters  
HP NC522SFP Dual Port 10GbE Gigabit Server Adapter
NOTE: A minimum of two Gigabytes (2 GB) of server memory is required per each NC522SFP adapter.
NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately.
468332-B21
HP NC524SFP Dual Port 10GbE Server Adapter
NOTE: One NC524SFP allowed per system; a minimum of two gigabytes (2 GB) of server memory is required for the NC524SFP module.
NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately.
489892-B21
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs.  
Smart-mini DIMM Module  
HP ML370 G6 and DL370 G6 Smart-mini DIMM Module
NOTE: By plugging the Smart-mini DIMM Module to the HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter, TCP/IP Offload Engine (TOE) for Windows is enabled/supported.
519808-B21

Riser Cage Options
HP DL370 G6 2 Slot PCI-X Riser Kit
NOTE: Customers purchasing the PCI-X Riser Kit, must also purchase the Redundant Fan kit (508107-B21)
516434-B21

Power Supplies CAUTION: Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor. In ProLiant Servers that have more than one power slot (bay), only same size power supplies are recommended. If non-matched power supplies are inserted you will get errors and operation will fail.
HP 460W CS HE Gold Power Supply
503296-B21
HP 750W CS HE Gold Power Supply
512327-B21
HP 1200W CS HE Silver Power Supply
500172-B21
NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables.
Power Options  
HP ML370 G6 and DL370 G6 Redundant Fan Kit 508107-B21
contents
 Overview      Standard Features      HPC Interconnects      Models      Smart Buys      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Additional Options

HP Insight Software HP Insight Control server deployment  

HP Insight Control server deployment, Electronic License including 1 year of 24x7 Technical Support and Updates

T9082AAE
NOTE: Electronic and Flexible-Quantity licenses can be used to purchase multiple licenses with a single activation key.
NOTE: Electronic software is available in all countries except China and Japan. Customers in China and Japan should order the physical equivalent.
NOTE: Customer will receive a license entitlement certificate. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service.
NOTE: Licenses ship without media. The HP Insight Control Media Kit can be ordered separately, or can be downloaded at: http://www.hp.com/go/insightupdates.
NOTE: For additional license options please see the Insight Control QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12631_na/12631_na.html
 
HP Insight Control for Linux  
HP Insight Control for Linux, 1-server license, including one year of 24x7 Technical Support and Updates, Electronic T9084BAE
HP Insight Control for Linux, No Media, 1-Server license, including one year of 24x7 Technical Support and Updates 464423-B22
HP Insight Control for Linux, Media pack (DVD) - No licenses included
NOTE: Media pack DVD contains HP Insight Control for Linux, HP Systems Insight Manager, HP Insight Control power management, HP Insight Control virtual machine management, and an integrated installer. Servers must be acquired separately.
464422-B22
NOTE: Licenses ship without media. The HP Insight Control Media Kit can be ordered separately, or can be downloaded at: http://www.hp.com/go/insightupdates.
NOTE: Electronic software is available in all countries except China and Japan. Customers in China and Japan should order the physical equivalent.
NOTE: Electronic and Flexible-Quantity licenses can be used to purchase multiple licenses with a single set of activation keys.
NOTE: For additional License Kits, including electronic licensing options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_na/13019_na.html
 
HP Integrated Lights-Out Advanced  
HP Integrated Lights-Out Advanced, No Media, 1-Server License, including 1 year of 24x7 Technical Support and Updates
NOTE: This license allows 1 server to be deployed and managed via HP iLO Advanced. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service
NOTE: For additional license kits, including electronic delivery options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12362_na/12362_na.html
512485-B21
HP Insight Rapid Deployment software  
HP Insight Rapid Deployment software No Media 1-Server License including 1 year of 24x7 Technical Support and Updates
NOTE: This license allows 1 server to be deployed and managed via RDP. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service
NOTE: For additional license kits, including electronic delivery options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.html
452151-B21

Drive Cage Options (8) Small Form Factor (SFF) 2nd Drive Cage Kit 507803-B21
(6) Large Form Factor (LFF) Backplane Kit
507810-B21
(2) Large Form Factor (LFF) Drive Cage Kit
487936-B21

Graphic Cards

HP ML370 G6 and DL370 G6 Graphic Card Cable Kit
NOTE: An option kit will be required per Graphic Card.
537721-B21
NOTE: 2 PCIe Gen2 x16 (mechanical/electrical); 1 PCIe Gen2 x16 (mechanical) x8 (electrical)  

Security HP Trusted Platform Module Option Kit
488069-B21

Storage Controllers SAS Controllers  
HP Smart Array P800 Controller  
HP Smart Array P800/512 BBWC Controller 381513-B21
HP Smart Array P212 Controller  
HP Smart Array P212/Zero Memory Controller

462828-B21

HP Smart Array P212/256 MB Controller 462834-B21
HP Smart Array P410 Controller

 

HP Smart Array P410/256 MB Controller 462862-B21
HP Smart Array P410/512 MB with BBWC Controller 462864-B21
HP Smart Array P411 Controller  
HP Smart Array P411/256 MB Controller 462830-B21
HP Smart Array P411/512 MB with BBWC Controller 462832-B21
Optional Upgrades  
256 MB Cache Module
NOTE: Supported on HP Smart Array P212 Controller only.
462968-B21
512MB BBWC 462967-B21
Battery Kit upgrade
NOTE: To enable BBWC on the 256MB cache.
NOTE: Supported on HP P410i Smart Array (integrated), HP Smart Array P212 Controller, HP Smart Array P410 Controller, and HP Smart Array P411 Controller only.
462969-B21
1G Flash Backed Write Cache
NOTE: Supported on the Smart Array P410i Controller only.
534562-B21
512MB Flash Backed Write Cache
NOTE: Supported on the Smart Array P410i Controller only.
534916-B21
HP 8484 to Mini SAS 33in Cable Assy
NOTE: Needed to support internal drives on the HP ProLiant DL370 G6 or the HP ProLiant ML370 G6 with the Smart Array P800 Controller.
591734-B21
HP Smart Array Advanced Pack No Media 1-Server license including 1yr 24x7 Technical Support
NOTE: This part number can be used to purchase a single license or to order multiple licenses with a single activation key. Customers will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Include one year of 24x7 HP Software Technical Support Services.
516471-B21
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12616_na/12616_na.html
(Smart Array P800 Controller)
http://h18000.www1.hp.com/products/quickspecs/13203_na/13203_na.html
(Smart Array P212 Controller)
http://h18000.www1.hp.com/products/quickspecs/13201_na/13201_na.html
(Smart Array P410 Controller)
http://h18000.www1.hp.com/products/quickspecs/13202_na/13202_na.html
(Smart Array P411 Controller)
 
SAS Controller Options  
HP SAS Expander Card
NOTE: For use with the additional 8 SFF drive cage (507803-B21).
468406-B21
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
http://h18004.www1.hp.com/products/quickspecs/13232_na/13232_na.html
(SAS Expander Card)
 
SAS HBA  
HP SC08Ge Host Bus Adapter 488765-B21
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
http://h18004.www1.hp.com/products/quickspecs/13082_na/13082_na.html
(SC08Ge HBA)
 

Power Cords NOTE: HP ProLiant servers ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs).
Nema 5-15P to IEC320-C13, low voltage (6 ft/2 m) AF556A

Tape Storage

NOTE: For the complete listing of Tape Drive offerings, please see:
http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html

For recommended tape drive offerings for this ProLiant server see the following:

 
Tape Drives
USB Rack-Mount Tape Solutions  
HP StorageWorks DAT 160 USB Internal Drive
Q1580A
DAT 320 WW SAS External Tape Drive AJ828A
DAT 320 USB External Tape Drive AJ823A
HP DAT 320 USB Internal Tape Drive AJ825A
HP 1U DAT320 USB Rack Enclosure AP835A
SAS Rack-Mount Tape Solutions
HP DAT 320 SAS Internal Tape Drive AJ830A
HP StorageWorks LTO-2 Ultrium 448 SAS Internal Tape Drive DW085A
HP StorageWorks LTO-3 Ultrium 920 SAS Internal Tape Drive EH847A
HP StorageWorks LTO-4 Ultrium 1760 SAS Internal Tape Drive
EH919A
NOTE: For the ML370 G6, HP recommends purchasing the HP Smart Array P212 Controller (462828-B21) for a dedicated SAS HBA for tape.
NOTE:
Please refer to the "Tape Drives, Tape Autoloaders & Tape Libraries" table in the Storage section of this document for a list of SAS controllers with tape support.
HP StorageWorks 1/8 G2 Tape Autoloader  
HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader AK377A
HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Autoloader AH558A
HP StorageWorks 1/8 G2 Tape Autoloader Rack Kit AH166A
NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions.  
NOTE: Please reference the Tape Autoloader QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs.  
HP StorageWorks MSL2024 Tape Library  
HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SAS Drive Library AK378A
HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SAS Drive Library AH559A
HP StorageWorks MSL4048 Tape Library  
HP StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SAS Drive Library AK380A
HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SAS Drive Library AH560A
NOTE: Please reference the MSL Tape Library QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs.  

Disk-Based BackupRDX Removable Disk Backup
HP StorageWorks RDX500 Internal Removable Disk Backup System
NOTE: 500GB of Disk Storage.
AJ934A
D2D Backup 
HP StorageWorks D2D120 Backup System with Data Protector Express Software Kit
NOTE: 2TB of Disk Storage.
EH924A
HP StorageWorks D2D130 Backup System with LTO-3 Ultrium 920 SAS Tape Drive
NOTE: 3TB of Disk Storage.
EH952A
HP StorageWorks D2D2503i Backup System
NOTE: 3TB of Disk Storage.
EH945A
HP StorageWorks D2D4004i Backup System
NOTE: 4.5TB of Disk Storage.
EH938A
NOTE: Please see the HP D2D Backup Systems QuickSpecs for additional information: http://www.hp.com/go/d2d.  

StorageWorks Options StorageWorks Fibre Channel HBA
NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows and Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html
 
Brocade Fibre Channel HBAs  
HP StorageWorks 81B PCI-e FC HBA Single Port
AP769A
HP StorageWorks 82B PCI-e FC HBA Dual Port AP770A
HP StorageWorks 41B 4Gb PCI-e FC HBA AP767A
HP StorageWorks 42B 4Gb Dual-Port PCI-e FC HBA AP768A
Emulex Fibre Channel HBAs  
HP StorageWorks 81E PCI-e FC HBA Single Port AJ762A
HP StorageWorks 82E PCI-e FC HBA Dual Port AJ763A
HP StorageWorks FC2142 4Gb PCI-e HBA A8002A
HP StorageWorks FC2242 Dual Channel 4Gb PCI-e HBA A8003A
QLogic Fibre Channel HBAs  
HP StorageWorks 81Q PCI-e FC HBA Single Port AK344A
HP StorageWorks 82Q PCI-e FC HBA Dual Port AJ764A
HP StorageWorks FC1142 4Gb PCI-e HBA AE311A
HP StorageWorks FC1242 Dual Channel 4Gb PCI-e HBA AE312A

HP StorageWorks Modular Smart Array

MSA SAN Storage Arrays  
HP StorageWorks 50 Modular Smart Array 364430-B21
NOTE: Please see the Modular Smart Array 50 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/12245_na/12245_na.html  
HP StorageWorks 60 Modular Smart Array 418408-B21
NOTE: Please see the Modular Smart Array 60 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/12627_na/12627_na.html  
HP StorageWorks 70 Modular Smart Array 418800-B21
NOTE: Please see the Modular Smart Array 70 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/12652_na/12652_na.html  

Uninterruptible Power Systems

HP Tower UPS  
HP T1500 G3 UPS Models  
HP T1500 G3 UPS AF450A
NOTE: Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/13160_na/13160_na.html
 
HP Rack-mountable UPS  
HP R1500 G2 UPS  
HP, R1.5kVA UPS, 1U AF419A
NOTE: Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/12507_na/12507_na.html
 
HP R3000 UPS  
HP R3000 VA UPS, 2U, Low Voltage L5-30 AF422A
HP R3000 VA UPS, 2U, High Voltage L6-20 AF423A
NOTE: Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/10671_na/10671_na.html
 
HP R/T3000 Uninterruptible Power System (UPS)  
HP R/T3000 UPS, Low voltage AF452A
HP R/T3000 UPS, High voltage AF453A
NOTE: Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/13417_na/13417_na.html
 
HP Rack-Mountable R5500 UPS  
HP R5500 VA UPS AF426A
NOTE: Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/11871_na/11871_na.html
 
NOTE: For additional information on HP Uninterruptible Power Systems please go to: www.hp.com/servers/rackups.  

Power Distribution Units

Monitored PDUs  
HP Monitored Power Distribution Unit: Full Rack Version  
HP 17.3 kVA S2324 Monitored PDU- dual input, 3Ø, 24A
AF503A
HP 8.6 kVA S1324 Monitored PDU- single input, 3Ø, 24A
AF504A
HP 16.6 kVA S2140 Monitored PDU- dual input, 1Ø, 40A
AF505A
HP 8.3 S1140 Monitored PDU- single input, 1Ø, 40A
AF506A
HP Monitored Power Distribution Unit: Half Rack Version
HP 4.9 kVA S124 Monitored PDU- single input, 1Ø, 24A
AF914A
Modular Power Distribution Units 1U/0U (Up to 32 outlets)  
HP Two Fixed Cord Extension Bars
NOTE: Two extension bar sticks; each with (7) C13 plugs.
351655-B21
2.8 kVA Modular PDU, 24A 252663-D71
3.6 kVA Modular PDU, 16A 252663-B24
4.9 kVA Modular PDU, 24A 252663-D72
8.3 kVA Modular PDU, 40A 252663-B21
8.3 kVA Modular PDU, 40A 252663-D73
8.3 kVA Modular PDU, 40A 252663-D75
4.9 kVA Modular PDU, 24A 252663-D74
NOTE: For additional information on HP Power Distribution Units including accessories please go to: www.hp.com/go/pdu (Worldwide)  

HP Rack Series HP Rack 5000 Series (Graphite Metallic)  
HP 5642 Rack-Unassembled 358254-B21
NOTE: Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.html
 
HP Rack 10000 G2 Series (Carbon/Graphite Metallic)  
10642 G2 (42U) Rack Cabinet 1200mm Deep - Shock Pallet AF034A
10642 G2 (42U) Rack Cabinet 1200mm Deep - Pallet AF038A
10647 G2 (47U) Rack Cabinet 1200mm Deep - Shock Pallet
NOTE: Due to handling and shipping requirements, AF044A is only orderable through HP Factory Express. It is not for direct sales. Customer site surveys are required before an order is approved. CTO orders may require additional lead time.
AF044A
10647 G2 (47U) Rack Cabinet 1200mm Deep - Pallet AF045A
NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed.
NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels).
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower.
 

HP Rack Options Monitors and keyboards  
TFT7600 Rackmount Keyboard Monitor
AG052A
HP TAA TFT7600 Rkmntkybd 17in Monitor AG067A
1U Rackmount Keyboard with USB
AG072A
NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower.  
HP KVM Switch Options  
2x1x16 IP Console Switch with Virtual Media AF601A
4x1x16 IP Console Switch with Virtual Media AF602A
1x1Ex8 KVM IP Console Switch G2 with Virtual Media and CAC AF620A
2x1Ex16 KVM IP Console Switch G2 with Virtual Media and CAC AF621A
4x1Ex32 KVM IP Console Switch G2 with Virtual Media and CAC AF622A
2x16 Server Console Switch with Virtual Media AF600A
0x2x16 KVM Server Console G2 Switch with Virtual Media and CAC AF618A
0x2x32 KVM Server Console G2 Switch with Virtual Media and CAC AF619A
PS/2 Virtual Media Interface Adapter, 1 pack
NOTE: Requires PS/2 and one USB port on server.
AF604A
Server console switch 0x2x8 AF616A
Server console switch 0x2x16 AF617A
HP TAA Server console switch 0x2x16 AF626A
PS/2 Interface Adapter, 1 pack 262588-B21
PS/2 Interface Adapter, 8 pack 262587-B21
NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm.  
HP 1x4 Console Switch AF611A
PS2 Server Console Cable, 6 ft, 2 pack AF612A
HP 1x4 KVM Console 6ft USB Cable AF613A
NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm.  
HP Serial Console Server Options  
HP 16 Port Serial Console Server AF101A
HP 48 Port Serial Console Server AF102A
Serial Adapter, RJ45-DB9 DCE Female, 1 Pack AF103A
Serial Adapter, RJ45-DB9 DCE Female, 8 Pack AF110A
NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm.  
NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm.  
Rack Kits  
HP ML370G6 Tower to Rack Conversion Kit 515031-B21

USB and SD Options HP 1.44MB USB External Floppy Drive
DC141B
HP USB 2-Button Optical Scroll Mouse
DC172B
HP Standard USB Keyboard US
DT528A#ABA
HP 4GB SD Flash Media Kit
NOTE: Blank USB and SD media device is supported for use withVMware and Citrix. USB/SD media must be installed in the internal slot of the ProLiant server. Learn more at: http://www.hp.com/go/proliantvirtualization.
580387-B21

Service and Support Offerings
(HP Care Pack Services)
HP ProLiant ML370 G6 Service & Support Offerings  
Hardware Services On-site Service
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic U4528E
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic U4529E
Hardware Services 6-Hour Call to Repair On-site Service  
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic U4530E
Installation & Start-up Services  
Hardware Installation, Electronic U4538E
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays, Electronic U4539E
Support Plus  
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic U4540E
Support Plus 24  
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic U4541E
Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic U6311E
Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic U8333E
HP ProLiant DL370 G6 Service & Support Offerings  
Hardware Services On-site Service  
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic UM752E
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic UM753E
Hardware Services 6-Hour Call to Repair On-site Service  
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic UM754E
Installation & Start-up Services  
Hardware Installation, Electronic UM777E
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays, Electronic UM778E
Support Plus  
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic This service level no longer being offered
Support Plus 24  
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic UM763E
Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic UM764E
Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic UM765E
NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack.  
contents
 Overview      Standard Features      HPC Interconnects      Models      Smart Buys      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Memory

NOTE: Memory configurations listed do not apply to "Factory Integrated Models".

HP ProLiant DL370 G6 Models
HP ProLiant ML370 G6 Models
DDR3 memory population guidelines

For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator

Some DIMM installation guidelines are summarized below:

  • For servers with eighteen (18) memory slots:
    • There are three (3) channels per processor; six (6) channels per server
    • There are three (3) DIMM slots for each memory channel; eighteen (18) total slots
    • Memory channel 1 consists of the three (3) DIMMs that are closest to the processor
    • Memory channel 3 consists of the three (3) DIMMs that are furthest from the processor
  • DIMM slots that are white should be populated first
  • Do not mix Unbuffered memory (UDIMMs) with Registered memory (RDIMMs)
  • Do not install DIMMs if the corresponding processor is not installed
  • If only one processor is installed in a 2CPU system, only half of the DIMM slots are available
  • To maximize performance, balance the total memory capacity between all installed processors
  • It is not required, but it is recommended to load the channels similarly if possible
  • You can only have up to eight (8) ranks installed per channel
  • You can only install two quad-rank DIMMs per channel
  • You can only install two UDIMMs per channel; if available, the third slot in the channel must remain empty
  • Populate DIMMs from heaviest load (quad-rank) to lightest load (single-rank) within a channel
  • Heaviest load (DIMM with most ranks) within a channel goes furthest from the chipset
  • For memory mirroring mode, channel 3 must be unpopulated. Channels 1 and 2 are populated identically
  • For lock-step mode, channel 3 must be unpopulated. DIMMs in channels 1 and 2 will be installed in pairs. The paired slots will be 1,4; 2,5; 3;6 on a 3DPC system or 1,4; 2,5; on a 2DPC system
  • No mixing DIMM voltage; all DIMMs must be the same voltage
DIMM Type -> Registered Dimms (RDIMMs) Unbuffered with ECC DIMMs (UDIMMs)
DIMM Rank -> Dual Rank (2R) Quad Rank (4R) Single Rank (1R) Dual Rank (2R)
DIMM Capacity -> 2GB 4GB 8GB 8GB 4GB 16GB 1GB 2GB
DIMM Native Speed (MHz) -> 1333 1333 1066 1333
1066 1066 1333 1333
Part Number 500656-B21 500658-B21 516423-B21 500662-B21 500660-B21 500666-B21 500668-B21 500670-B21
                 
SLOTS THAT CAN BE POPULATED
18 slot servers 18 18 18 18 12 12 12 12
                 
MAXIMUM CAPACITY (GB)
18 slot servers 36 72 144 144 48 192 12 24
                 
POPULATED DIMM SPEED (MHz)
1 DIMM Per Channel 1333 1333 1066 1333

1066 1066 1333 1333
2 DIMM Per Channel 1066 1066 1066 1333*
800 800 1066 1066
3 DIMM Per Channel 800 800 800 800 n/a n/a n/a n/a
* Supported with ROM update via ROM Based Setup Utility (RBSU).

NOTES:

  • Mixing DIMM speeds is allowed, but the system processor speed rules always override the DIMM capabilities
  • If you do mix DIMM speeds, the memory bus will default to the minimum clock rate of all DIMMs in the system - even if the slower DIMM is on the other processor
  • If you install 1x 1066MHz DIMM in channel 1 and 1x 1333MHz DIMM in channel 2, you still run at 1066MHz
  • If you install 1x 1066MHz DIMM in channel 1 and 5x 1333MHz DIMMs with 1 DIMM Per Channel (DPC) in each of the other channels, you run at 1066MHz
  • If you install 3DPC in one channel (if applicable) and 1DPC in all other channels, you run at 800MHz
  • 95 Watt CPU's are required for 1333MHz DIMM speeds.
  • References to the above MHz speeds are for the various speeds of DDR3 DIMMs; 1333 refers to DDR3-1333, etc.
 

DIMM slot and configuration diagrams
Basic memory slot & population diagram

  • Population order; start with "A" first, "B" second, "C" third, etc.
18 DIMM SLOTS (9 per CPU node)
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11G1GChnl 1
2D2D
3A3A
      
Chnl 24H4HChnl 2
5E5E
6B6B
      
Chnl 37I7IChnl 3
8F8F
9C9C
 

Standard memory configuration (1 CPU model)

  • 6GB, consisting of three (3) 2GB dual-rank PC3-10600 RDIMMs
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11G; empty1G; emptyChnl 1
2D; empty2D; empty
3A; 2GB DIMM3A; empty
      
Chnl 24H; empty4H; emptyChnl 2
5E; empty5E; empty
6B; 2GB DIMM6B; empty
      
Chnl 37I; empty7I; emptyChnl 3
8F; empty8F; empty
9C; 2GB DIMM9C; empty
 

Standard memory plus optional memory (1 CPU model)

  • 54GB, consisting of three (3) 2GB RDIMMs plus six (6) 8GB RDIMMs
    • 3x 2GB dual-rank PC3-10600 RDIMMs
    • 6x 8GB dual-rank PC3-10600 or PC3-8500 RDIMMs
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11G; 8GB DIMM1G; emptyChnl 1
2D; 8GB DIMM2D; empty
3A; 2GB DIMM3A; empty
      
Chnl 24H; 8GB DIMM4H; emptyChnl 2
5E; 8GB DIMM5E; empty
6B; 2GB DIMM6B; empty
      
Chnl 37I; 8GB DIMM7I; emptyChnl 3
8F; 8GB DIMM8F; empty
9C; 2GB DIMM9C; empty
 

Standard memory replaced with optional memory (1 CPU model)
RDIMM maximum configuration

  • 72GB, consisting of nine (9) 8GB dual-rank PC3-10600 or PC3-8500 RDIMMs
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11G; 8GB DIMM1G; emptyChnl 1
2D; 8GB DIMM2D; empty
3A; 8GB DIMM3A; empty
      
Chnl 24H; 8GB DIMM4H; emptyChnl 2
5E; 8GB DIMM5E; empty
6B; 8GB DIMM6B; empty
      
Chnl 37I; 8GB DIMM7I; emptyChnl 3
8F; 8GB DIMM8F; empty
 

UDIMM maximum configuration (1 CPU model)

  • 12GB, consisting of six (6) 2GB dual-rank PC3-10600 UDIMMs
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11G; empty1G; emptyChnl 1
2D; 2GB DIMM2D; empty
3A; 2GB DIMM3A; empty
      
Chnl 24H; empty4H; emptyChnl 2
5E; 2GB DIMM5E; empty
6B; 2GB DIMM6B; empty
      
Chnl 37I; empty7I; emptyChnl 3
8F; 2GB DIMM8F; empty
9C; 2GB DIMM9C; empty
 

Standard memory replaced with optional memory (2 CPU model)
RDIMM maximum configuration

  • 192GB, consisting of twelve (12) 16GB Quad-Rank PC3-8500 RDIMMs
  CPU1 CPU2  
  slot # population order slot # population order  
Chnl 1 1 G; empty 1 G; empty Chnl 1
2 D; 16GB DIMM 2 D; 16GB DIMM
3 A; 16GB DIMM 3 A; 16GB DIMM
           
Chnl 2 4 H; empty 4 H; empty Chnl 2
5 E; 16GB DIMM 5 E; 16GB DIMM
6 B; 16GB DIMM 6 B; 16GB DIMM
           
Chnl 3 7 I; empty 7 I; empty Chnl 3
8 F; 16GB DIMM 8 F; 16GB DIMM
9 C; 16GB DIMM 9 C; 16GB DIMM
 

UDIMM maximum configuration (2 CPU model)

  • 24GB, consisting of twelve (12) 2GB dual-rank PC3-10600 UDIMMs
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11G; empty1G; emptyChnl 1
2D; 2GB DIMM2D; 2GB DIMM
3A; 2GB DIMM3A; 2GB DIMM
      
Chnl 24H; empty4H; emptyChnl 2
5E; 2GB DIMM5E; 2GB DIMM
6B; 2GB DIMM6B; 2GB DIMM
      
Chnl 37I; empty7I; emptyChnl 3
8F; 2GB DIMM8F; 2GB DIMM
9C; 2GB DIMM9C; 2GB DIMM
 

NOTE: Capacity references are rounded to the common Gigabyte values.

  • 1GB = 1024MB
  • 2GB = 2048MB
  • 4GB = 4096MB
  • 8GB = 8192MB
  • 16GB = 16384MB
Following are memory options available from HP:
Memory Registered DIMMs (RDIMMs)  
HP 2GB 2Rx8 PC3-10600R-9 Kit 500656-B21
HP 4GB 2Rx4 PC3-10600R-9 Kit 500658-B21
HP 4GB 4Rx8 PC3-8500R-7 LP Kit 500660-B21
HP 8GB 2Rx4 PC3-8500R-7 Kit 516423-B21
HP 8GB 2Rx4 PC3-10600R-9 Kit 500662-B21
HP 16GB 4Rx4 PC3-8500R-7 Kit 500666-B21
Unbuffered with ECC DIMMs (UDIMMs)  
HP 1GB 1Rx8 PC3-10600E-9 Kit 500668-B21
HP 2GB 2Rx8 PC3-10600E-9 Kit 500670-B21
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient.
 
contents
 Overview      Standard Features      HPC Interconnects      Models      Smart Buys      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Storage

A
Removable media bay
B SATA DVD-ROM Drive (Standard in all BTO Models)
COptical Drive (blank)
1-8
Eight SFF SAS/SATA HDD Bays (Standard in all BTO Models)
A
Removable media bay
B
SATA DVD-ROM Drive (Standard in all BTO Models)
COptical Drive (blank)
1-8 Eight SFF SAS/SATA HDD Bays (Standard in all BTO Models)
1-24Twenty-four small form factor (SFF) hot-plug drive bays to support Serial-attached SCSI (SAS) and Serial ATA (SATA) drives with optional drive cages (up to three 8 SFF drive cage can be installed)
1-14Fourteen large form factor (LFF) hot-plug drive bays to support Serial-attached SCSI (SAS) and Serial ATA (SATA) drives with optional drive cages
 

Drive Support


 

Quantity
Supported

Position
Supported

Controller

Removable Media

 
Half-Height SATA DVD-ROM Optical Drive
Up to 2
A, B
Integrated IDE
Half-Height SATA DVD RW Optical Drive
Up to 2

A, B
Integrated IDE
HP Slim SATA DVD-ROM Optical Drive 1
NOTE: Also please use if the 3 drive cage is populated
CIntegrated IDE
HP Slim SATA DVD RW Optical Drive 1
NOTE: Also please use if the 3 drive cage is populated
CIntegrated IDE

Hard Drives
NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.
SAS Hot Plug SFF Enterprise (ENT) Drives
 
Quantity
Supported
Position
Supported
Controller
300GB 6G SAS 10K DP 300GB 3G SAS 10K DP
146GB 6G SAS 15K DP
146GB 3G SAS 15K DP
146GB 6G SAS 10K DP 146GB 3G SAS 10K DP 72GB 6G SAS 15K DP
72GB 3G SAS 15K DP
72GB 3G SAS 10K DP
Up to 24
1-8
1-24
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller

SAS Hot Plug 3.5" Enterprise (ENT) Drives
 
Quantity
Supported
Position
Supported
Controller
600GB 6G SAS 15K DP
450GB 6G SAS 15K DP 450GB 3G SAS 15K DP
300GB 6G SAS 15K DP 300GB 3G SAS 15K DP
146GB 3G SAS 15K DP
Up to 14 1-14 HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller

SAS Hot Plug SFF Midline (MDL) Drives
 
Quantity
Supported
Position
Supported
Controller
500GB 6G SAS 7.2K DP Up to 14 1-14 HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller

SAS Hot Plug 3.5" Midline (MDL) Drives
 
Quantity
Supported
Position
Supported
Controller
1TB 3G SAS 7.2K DP
750GB 3G SAS 7.2K DP
Up to 14 1-14 HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller

SATA Hot Plug SFF Midline (MDL) Drives
 
Quantity
Supported
Position
Supported
Controller
500GB 3G SATA 7.2K
160GB 3G SATA 7.2K
Up to 24 1-8
1-24
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller

SATA Hot Plug 3.5" Midline (MDL) Drives
 
Quantity
Supported
Position
Supported
Controller
1TB 3G SATA 7.2K
750GB 3G SATA 7.2K
500GB 3G SATA 7.2K
250GB 3G SATA 7.2K
Up to 14 1-14 HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller

SATA Hot Plug SFF Entry (ETY) Drives
 
Quantity
Supported
Position
Supported
Controller
250GB 3G SATA 5.4K
120GB 1.5G SATA 5.4K
Up to 24
1-8
1-24
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller

SATA Hot Plug 3.5" Entry (ETY) Drives
 
Quantity
Supported
Position
Supported
Controller
160GB 3G SATA 7.2K
Up to 14
1-14
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller

SATA Hot Plug Midline (MDL) Solid State Drives
 
Quantity
Supported
Position
Supported
Controller
60GB 3.0G SATA SSD
120GB 3.0G SATA SSD
Up to 24
1-8
1-24
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller

SATA Hot Plug 3.5" Midline (MDL) Solid State Drives
 
Quantity
Supported
Position
Supported
Controller
60GB 3.0G SATA SSD
120GB 3.0G SATA SSD
Up to 14
1-14
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller

External Storage

 

Quantity
Supported

Position
Supported

Host Controller or Adapter

50 Modular Smart Array Up to 4ExternalHP Smart Array P800/512 BBWC Controller
60 Modular Smart ArrayUp to 4External
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
Up to 8
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller
HP Smart Array P800/512 BBWC Controller
70 Modular Smart Array
Up to 2
External
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
Up to 4
HP Smart Array P800/512 BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller

Tape and Disk-Based Backup
NOTE: For a complete listing of compatible tape and disk-based backup offerings, please visit: www.hp.com/go/connect.
 
Position
Supported
Controller

Part Number

Internal USB Tape Drives
DAT 40 USB
DAT 72 USB
DAT 160 USB
A
USB 2.0 Port
N/A
    
USB Tape Drives, External
DAT 40 USB
DAT 72 USB
DAT 160 USB
1U Rack-Mount Kit
External
USB 2.0 Port
N/A
 
 
SAS Tape Drives, Internal
DAT 160 SAS
LTO-2 Ultrium 448 SAS
LTO-3 Ultrium 920 SAS
LTO-4 Ultrium 1760 SAS
A
HP Smart Array P212/Zero Memory Controller
462828-B21
    
SAS Tape Drives, External
DAT 160 SAS
LTO-2 Ultrium 448 SAS
LTO-3 Ultrium 920 SAS
LTO-4 Ultrium 1760 SAS
LTO-4 Ultrium 1840 SAS
1U Rack-Mount
3U Rack-Mount
External
HP Smart Array P212/Zero Memory Controller
462828-B21
    
SAS Tape Automation, External
1/8 G2 Autoloader
MSL2024
MSL4048
MSL8096
External
HP Smart Array P212/Zero Memory Controller
462828-B21
 
 
Fibre Tape Automation, External
MSL2024
MSL4048
MSL8096
MSL6000
External
Please consult the EBS connectivity matrix at: http://www.hp.com/go/ebs for detailed connectivity information.
N/A
 
 
HP StorageWorks RDX Removable Disk Backup System, Internal
RDX160
RDX320
RDX500
AUSB 2.0 PortN/A
    
HP StorageWorks RDX Removable Disk Backup System, External
RDX160
RDX320
RDX500
ExternalUSB 2.0 PortN/A
    
HP StorageWorks D2D Backup Systems
D2D120
D2D130
D2D2500i
D2D4000i
External
Embedded Network Controller
N/A
contents
 Overview      Standard Features      HPC Interconnects      Models      Smart Buys      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Power Specifications

HP 460W Power Supply
Part Number - AC 460W PSU
503296-B21
Input Voltage Range (Vrms) 100 to 240
Frequency Range (Nominal) (Hz) 50/60
Nominal Input Voltage (Vrms) 100 120 208 200 220 230 240
Maximum Rated Output Wattage 460 460 460 460 460 460 460
Nominal Input Current (A rms) 5.5 4.5 2.6 2.5 2.4 2.3 2.2
Max Rated Input Wattage Rating (Watts) 526 520 505 505 503 503 503
Max. Rated VA (Volt-Amp) 548 542 527 527 524 524 524
Efficiency (%) at Max. Rated Output Wattage 87.5 88.5 91 91 91.5 91.5 91.5
Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97
Leakage Current (mA) 0.42 0.50 0.83 0.87 0.92 0.96 1.00
Max. Inrush Current (A peak) 30 30 30 30 30 30 30
Max. Inrush Current duration (mS) 20 20 20 20 20 20 20
Maximum British Thermal Unit Rating (BTU-Hr) 1794 1773 1725 1725 1715 1715 1715

 

HP 750W Power Supply
Part Number - AC 750W PSU
512327-B21
Input Voltage Range (Vrms) 100 to 240
Frequency Range (Nominal) (Hz) 50/60
Nominal Input Voltage (Vrms) 100 120 208 200 220 230 240
Maximum Rated Output Wattage 750 750 750 750 750 750 750
Nominal Input Current (A rms) 8.9 7.4 4.3 4.1 3.9 3.7 3.6
Max Rated Input Wattage Rating (Watts) 857 847 824 825 820 820 820
Max. Rated VA (Volt-Amp) 894 884 859 859 854 854 854
Efficiency (%) at Max. Rated Output Wattage 87.5 88.5 91 91 91.5 91.5 91.5
Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97
Leakage Current (mA) 0.42 0.50 0.83 0.87 0.92 0.96 1.00
Max. Inrush Current (A peak) 30 30 30 30 30 30 30
Max. Inrush Current duration (mS) 20 20 20 20 20 20 20
Maximum British Thermal Unit Rating (BTU-Hr) 2925 2892 2812 2812 2797 2797 2797
 
HP 1200W Power Supply
Part Number - AC
500172-B21
Operational Input Voltage Range (Vrms) 100 to 240
Frequency Range (Nominal) (Hz) 50/60
Nominal Input Voltage (Vrms) 100 120 208 200 220 230 240
Maximum Rated Output Wattage 800 900 1200 1200 1200 1200 1200
Nominal Input Current (A rms) 9.7 9.0 7.0 6.8 6.4 9.1 5.9
Max Rated Input Wattage Rating (Watts) 930 1034 1348 1348 1348 1348 1348
Max. Rated VA (Volt-Amp) 970 1079 1406 1406 1406 1406 1406
Efficiency (%) at Max. Rated Output Wattage 86 87 89 89 89 89 89
Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97
Leakage Current (mA) 0.42 0.50 0.83 0.87 0.92 0.96 1.00
Max. Inrush Current (A peak) 30 30 30 30 30 30 30
Max. Inrush Current duration (mS) 20 20 20 20 20 20 20
Maximum British Thermal Unit Rating (BTU-Hr) 3174 3530 4600 4600 4600 4600 4600
 

To review typical system power ratings use the Active Answers HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor

To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL370 G6 or ML370 G6
- Click on: "Power Calculator" link. (You may need to scroll down to see it)

contents
 Overview      Standard Features      HPC Interconnects      Models      Smart Buys      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Technical Specifications

System Unit Tower Dimensions
(H x W x D) (with bezel)
18.52 x 9.75 x 29.12 in (47.04 x 24.77 x 73..96 cm)
Rack Dimensions
(H x W x D) (with bezel)
6.88 x 19.03 x 27.53 in (17.48 x 48.34 x 69.93 cm)
Tower Weight
(approximate)

 

Maximum
(two hard drives, power supply, and processor installed)
103.06 lbs (46.75 kg)
Minimum
(one hard drive, power supply, and processor installed)
66,14 lbs (30.00 kg)

Rack Weight
(approximate)

Maximum
(two hard drives, power supply, and processor installed)
103.06 lbs (46,75 kg)
Minimum
(one hard drive, power supply, and processor installed)
55.12 lbs (25.00 kg)
Input Requirements
(per power supply)
Rated Line Voltage90 - 132 VAC,
180 - 264 VAC
Rated Input Current7.5A (at 100 VAC),
3.8A (at 200 VAC)
Rated Input Frequency47 to 63 Hz
Rated Input Power980W (at 100 VAC)
1035W (at 120 VAC)
1170W (at 240 VAC)
BTU RatingMaximum 460W - 1773 BTU / hr (at 120 VAC), 1715 (at 240 VAC)
750W - 2892 BTU / hr (at 120 VAC), 2797 (at 240 VAC)
1200W - 3530 BTU / hr (at 120 VAC), 4600 (at 240 VAC)
Power Specifications

To review typical system power ratings use the HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient

- Click on the system of interest. Example: DL370 G6 or ML370 G6
- Follow the instructions of the next screens.

Power Supply Output
(per power supply)
Rated Steady-State Power460 W (at 100 VAC)
Maximum Peak Power460 W (at 200 VAC)
460 W (at 100 VAC)
460 W (at 200 VAC)
NOTE: See Power Supply Specifications tables for complete details on 460W PSU and optional 750W and 1200W Power Supply Options.
System Inlet TemperatureOperating10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed.
System performance may be reduced if operating with a fan fault or above 30°C (86°F).
Non-operating-30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing.
Non-operating5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing.
AltitudeOperating3048 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
Non-operating9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
Acoustic NoiseListed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
Idle 
L WAd
5.6 B for 1P Non-Redundant; 5.5 B for 2P Redundant
L pAm
39 dB for 1P Non-Redundant; 39 dB for 2P Redundant
Operating
 
L WAd
5.6 B for 1P Non-Redundant; 5.5 B for 2P Redundant
L pAm
39 dB for 1P Non-Redundant; 39 dB for 2P Redundant
NOTE: The Listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels.
Emissions Classification (EMC)FCC RatingClass B
Normative StandardsCISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1
NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements.

Smart Array P410i Controller

Dimensions
(not including bracket)
Low Profile PCIe Form Factor
7.5 in x 9.5 in x 2.25 in (19.05 cm x 24.13 cm x 5.72 cm)
Disk Drive and Enclosure Interface - Transfer rate 6Gb/s SAS (Serial Attached SCSI)
3Gb/s SATA (Serial ATA)
SAS Connectors 2 internal (Mini-SAS) x8 wide port connectors
Cache Memory Speed DDR2-800MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s maximum bandwidth.
Server Interface x8 5G PCIe 2.0 provides 4GB/s maximum bandwidth
SAS Speed x8 3G SAS provides 2.4GB/s maximum bandwidth
Cache Memory 40-bit 256MB ECC protected cache (72-bit 512MB BBWC module upgrades available); transportable with battery-backed upgrade
Logical Drives Supported Up to 64 logical drives
Maximum Logical Drive Capacity Greater than 2TB
Host Memory Addressing 64-bit, supporting greater than 4GB server memory space
RAID Support RAID 6, 6+0 (Advanced Data Guarding)
NOTE: The minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade is required to enable RAID 6, 6+0
RAID 5, 5+0 (Distributed Data Guarding)
NOTE: The 256MB upgrade is required to enable RAID 5 support on the Smart Array P410i.
RAID 1+0 (Striping & Mirroring)
RAID 0 (Striping)
Upgradeable Firmware Upgradeable Firmware with recovery ROM feature

NC375i Integrated Quad Port Multifunction Gigabit Server AdapterNetwork Interface10Base-T/100Base-TX/1000Base-TX
CompatibilityIEEE 802.3 10Base-T
IEEE 802.3ab 1000Base-T
IEEE 802.3u 100Base-TX
IEEE 802.3ad 1000Base-TX
IEEE 802.1p 100Base-TX
IEEE 802.1q 100Base-TX
Data Transfer MethodPCI Express, four lanes (x4)
Network Transfer Rate10Base-T (Half-Duplex)10 Mb/s
10Base-T (Full-Duplex)20 Mb/s
100Base-TX (Half-Duplex)100 Mb/s
100Base-TX (Full-Duplex)200 Mb/s
1000Base-TX (Half and Full-Duplex)2000 Mb/s
ConnectorRJ-45
Cable Support10Base-TCategories 3, 4 or 5 UTP up to 328 ft (100 m)
100Base-TX
Category 5 or higher UTP; up to 328 ft (100 m)
1000Base-TXCategory 5 or higher UTP; up to 328 ft (100 m)

Environment-friendly Products and Approach End-of-life Management and Recycling

Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner.

The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment.


© Copyright 2009 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice.
Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation.

The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less.


   DA-13242 16 - Version 16 - November 19, 2009