 Overview      Standard Features      Optional Features      Service and Support      Pre-configured Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Overview

HP ProLiant SL170z Generation 6 (G6)

The HP ProLiant SL170z is part of a new family, HP ProLiant SL6000, of HP server solutions optimized for scale-out customers to greatly reduce costs, maximize power efficiency, and maintain total flexibility. The SL6000 supports up to two independent HP ProLiant SL170z G6 Servers in the 2U HP ProLiant z6000 G6 Chassis. The servers share power supplies and fans, providing greater power and cooling efficiencies. The HP ProLiant SL170z G6 Server is a two socket Intel server with 16 DDR3 DIMM sockets.
Open View: Front View:
1. 16 DDR3 DIMM slots
1. Optional low profile x16 PCI-e Gen 2
2. Up to two Intel® 5600 sequence processors 2. Serial Port
3.

Six 3.5" or eight 2.5" non-hot plug hard drives using a quick release drive carrier

3. (2) 1Gbit NIC
4. Optional Dedicated Management port
    5. (2) USB Ports
    6. Power Button
    7. Health LED
    8. UID
    9. Video Port

What's New
  • Support for up to two Intel® 5600 sequence processors
  • Support for Low-voltage memory
contents
 Overview      Standard Features      Optional Features      Service and Support      Pre-configured Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Standard Features

NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - Factory Integrated Models" section.

Processor
One of the following depending on Model
Six-Core Processor
Intel® Xeon® Processor X5680 (3.33 GHz, 12MB L3 Cache, 130W, DDR3-1333, HT, Turbo 1/1/2/2/3/3)
Intel® Xeon® Processor X5670 (2.93 GHz, 12MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3/4/4)
Intel® Xeon® Processor X5660 (2.80 GHz, 12MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3/4/4)
Intel® Xeon® Processor X5650 (2.66 GHz, 12MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3/4/4)
Quad-Core Processors
Intel® Xeon® Processor E5640 (2.66 GHz, 12MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5630 (2.53 GHz, 12MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5620 (2.40 GHz, 12MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor L5640 (2.40 GHz, 12MB L3 Cache, 60W, DDR3-1066, HT, Turbo 2/2/3/3/4/4)
Intel® Xeon® Processor L5630 (2.13 GHz, 12MB L3 Cache, 40W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3)
Intel® Xeon® Processor X5560 (2.8 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo, 2/2/3/3)
Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo, 2/2/3/3)
Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800)
Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)
Intel® Xeon® Processor L5530 (2.40 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800)
Dual-Core Processors
Intel® Xeon® Processor E5503 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)
Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800)
NOTE: HT indicates that the processor model supports Intel® Hyper-Threading Technology
NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5500 and 5600 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream), and "L" denotes Lower Wattage.
NOTE: Up to 2 processors supported. Mixing different processor models is not supported.

Cache Memory
One of the following depending on Model
12MB (1 x 12MB) Level 3 cache
NOTE: All 5600 sequence processor models
8MB (1 x 8MB) Level 3 cache
NOTE: All processor models except for those identified below.
4MB (1 x 4MB) Level 3 cache
NOTE: For processors L5506, E5506, E5504, E5503 and E5502.

ChipsetIntel® 5520 Chipset
NOTE: For more information regarding Intel chipsets, please see the following URL:
http://www.intel.com/products/server/chipsets/

Upgradeability Upgradeable to two processors

Memory ProtectionAdvanced memory protection

Memory Type DDR3 Registered (RDIMM) or Unbuffered (UDIMM)
Standard (per server tray)
6 GB (3 x 2 GB) UDIMMs
Maximum (RDIMM) (per server tray)
192 GB (12 x 16 GB) for Registered Memory configurations using PC3-8500R DDR3 Registered (RDIMM) memory, operating at 800MHz when fully populated in 12 slots
Maximum (UDIMM) (per server tray) 48 GB (12 x 4 GB) for Unbuffered Memory configurations using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fully populated at 2 DIMMs per Channel in 12 slots
NOTE: Depending on the memory configuration and processor model, the memory speed may run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration Tool at: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient.

Network ControllerHP NC362i Integrated Dual Port Gigabit Server Adapter

Expansion Slots NOTE: One available PCI Express Gen 2.0 slots. Optional Slot 1: Low profile x16 PCI-Express 2.0.
Expansion Slots #
Technology
Bus Width**
Connector Width
Form Factor
Notes
1
PCI-Express 2.0
x16
x16
Low Profile
3.3 volts
** Indicates the number of physical electrical lanes running to the connector.

Storage Controller HP Embedded Smart Array B110i SATA RAID Controller (RAID 0, 1, 10) per server node
NOTE: To enable RAID on Embedded SATA, use the HP Smart Array B110i SATA Raid controller, To enable use of the B110i, enter the ROM based setup utility(RBSU). The option for enabling RAID can be found in the advanced section of the RBSU. For additional details www.hp.com/go/SATARAID.
NOTE: Transfer rate: 3.0 Gb/s SATA.
NOTE: A HP Smart Array controller is required for SAS Hard Drives
NOTE: An external diskette drive, USB floppy drive key or virtual FDD using LO100 Advanced Pack is needed to install storage controller drivers during a Windows operating system installation from a CD.

Storage Diskette Drives Via USB only
Optical Drives DVD / CD drives via USB only
NOTE: External support only.
Hard Drives None ship standard
Drive Bays Support for up to six 3.5" non-hot plug Serial ATA (SATA) or Serial Attached SCSI (SAS) hard drives using a quick release drive carrier.
Support for up to eight 2.5" non-hot plug Serial ATA (SATA), Serial Attached SCSI (SAS), or Solid State Drive (SSD) hard drives using a quick release drive carrier and the SFF drive cage.

Maximum Internal Storage Non-Hot Plug SATA 3.5" 12.0TB 6 x 2TB
Non-Hot Plug SAS 3.5" 1.8TB 6 x 300GB
Non-Hot Plug SATA 2.5" 4TB 8 x 500GB
Non-Hot Plug SAS 2.5" 2.4TB 8 x 300GB
Non-Hot Plug SSD 2.5" 960GB 8 x 120GB

Interfaces Serial 1
Parallel None
Network RJ-45 2 10/100/1000 NIC ports (1 NIC shared for the HP ProLiant Lights Out 100i Remote Management)
Graphics 1
Management

1 Optional Dedicated LO100i Management Port

Health LED 1 front per server node
Power 1 front per server node
UID 1 front per server node
USB 3 (two front, one internal)
NOTE: Please see the following URL for additional information regarding USB support:
http://h18004.www1.hp.com/products/servers/platforms/usb-support.html

Industry Standard ComplianceACPI V2.0 Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Microsoft® Logo certifications
IPMI 2.0
DCMI 1.0
SMASH CLP compliant

Server Power Cords

One 6' Highline (IEC-IEC) power cord ships standard
NOTE: HP ProLiant SL servers are primarily connected to PDU's in data center racks so they ship standard with only a PDU power cord (416151-B21). If a user wishes to power a ProLiant SL server using a 110V receptacle (NEMA-15), the NEMA power cord (227099-001) must be ordered separately.

NOTE: If customers require a local power cord, they can check the power cord matrix for the appropriate cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix.


Common Slot Power Supplies

HP has a new design for ProLiant power-supplies. The new Common Slot (CS) Power Supply provides the customer with commonality in power supplies across multiple platforms to save on the cost of spares and allows HP to offer multiple power solutions to fit the customers' needs. Many HP ProLiant Servers come with or are compatible with high-efficiency power without degrading performance of the ProLiant server. Power Supplies have efficiency ratings up to 94%. There are five right size power options to choose from depending on the configuration of your server. To make sure you select the correct power supply to meet your configuration, please use the HP Power Advisor at: www.hp.com/go/hppoweradvisor. All HP Common Slot power sources are UL, CE Mark Compliant, Hot Plug and Redundant.

It is highly recommended that you use the HP Power Calculator in defining the "Right-Size" power supply for your needs.

The HP ProLiant Common Slot Power supplies meet multiple Energy Efficiency Initiatives: Climate Savers Computing Initiative GOLD and ECOS Consulting 80PLUS GOLD for the 460w and 750w Power Supplies and Climate Savers Computing Initiative PLATINUM, ECOS Consulting 80PLUS PLATINUM for 1200w Power Supply. HP worked with the EPA on developing an ENERGY STAR Computer Server specification and we now offer models that meet the requirements. Please visit the ENERGY STAR website at: www.energystar.gov for a list of qualified platforms.

Optional power supplies can be purchased through power supply option kits (see Power Supply Options for part numbers).


System Fans3 system fans ship standard in z6000 chassis

Required Cabling For required cabling information, refer to the HP Web site at: www.hp.com/servers/sl170z.

Operating Systems and Virtualization Software Support for ProLiant Servers

Microsoft Windows Server
Microsoft Windows Server Hyper V
Microsoft HPC Server 2008
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
Solaris
VMware ESX
Citrix Essentials for XenServer

NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/ossupport and our driver download page www.hp.com/support/sl2x170zG6

Graphics

32MB shared supporting 1600x1200x16M resolution


Form FactorHP ProLiant z6000 G6 Chassis - 2U Chassis can support up to two SL170z server trays in the 2U chassis
HP ProLiant SL170z G6 Server - 1U server tray

Embedded Manageability

HP LO100 Advanced

HP Lights-Out 100 with Optional LO100 Advanced Licenses for Virtual KVM and Virtual Media.

Standard Features:

  • Embedded IPMI standard reporting
  • System event log access
  • Remote Serial console (serial redirection)
  • Browser, Telnet access
  • SMASH-CLP compliant
  • IPMI 2.0 compliant
  • DCMI 1.0 Compliant
  • Secure Socket Layer Encryption
  • Secure Shell Encryption

Licensed Features:

  • Virtual media (Floppy, CD, USB 2.0) with Advanced License
  • Virtual KVM with Advanced License

SecurityPower-on password
Setup password
Diskette boot control
Secure Sockets Layer (SSL)
Secure Shell (SSH)

Warranty

This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners. Hardware diagnostic support and repair is available for one year from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. Hard drives have either a one year or three year warranty.
NOTE: Server Warranty includes 1 year Parts, 1 year Labor, 1-year on-site support with next business day response. Warranty repairs may be accomplished through the use of Customer Self Repair (CSR) parts. These parts fall into two categories: 1) Mandatory CSR parts are designed for easy replacement. A travel and labor charge will result when customers decline to replace a Mandatory CSR part; 2) Optional CSR parts are also designed for easy replacement but may involve added complexity. Customers may choose to have HP replace Optional CSR parts at no charge. Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html.

contents
 Overview      Standard Features      Optional Features      Service and Support      Pre-configured Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Optional Features

HP Insight management software HP Insight Control for Linux

HP Insight Control for Linux (IC-Linux), as a product option, delivers essential lifecycle management that can help save time and money by integrating discovery, server deployment, firmware updates & provisioning, health & performance management, remote management, and virtualization. This makes it easy to optimize your IT infrastructure through a single, simple management console. The IC-Linux suite installs and licenses software modules that are integrated into HP System Insight Manager (HP SIM).

HP Insight Control for Linux serves environments requiring a Linux-based management console. See www.hp.com/go/ic-linux.

HP Insight Control for Linux includes one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/insight


Core Infrastructure Management

HP Systems Insight Manager

HP Systems Insight Manager (HP SIM) provides a unified, secure and extensible standards-based environment to centrally manage servers, storage and other infrastructure devices, (both HP and non-HP) across multiple operating system platforms.

For additional information, please see: http://www.hp.com/go/insight.

Insight Management Agents

HP Insight Management Agents and Insight Management Providers are available for HP Systems Insight Manager (SIM) Integration.

ProLiant 100-series G6 servers can use the same SNMP based Insight Management Agents supported by other ProLiant servers. As a result, administrators can use HP Systems Insight Manager (SIM) 5.3 and greater to manage ProLiant 100-series G6 servers. Administrators can also use any other SNMP- based management tool. These agents are obtained as part of the ProLiant 100-series model-specific "Easy Set-up" CDs, or through http://www.hp.com/servers/easysetup

The following capabilities are enabled on the 100-series G6 servers by the SNMP agents:

  • Health monitoring capabilities, including monitoring for drives, fans, network, power supplies, and temperature
  • Alerting capabilities, including basic alert notification for Smart Array drive pre-failure only
  • Performance monitoring capabilities providing information on processor, memory, disk free space, network utilization

For additional information, please see: http://www.hp.com/go/insight

Easy Set-up CD

The HP ProLiant Easy Set-up CDs and ISO image downloads offer Assisted and Manual single server installation, setup, and deployment capability. Capabilities provided are:

  • AutoRun
  • Assisted Installation Microsoft Windows 2003 Server and Microsoft Windows 2008 Server.
  • OS and SW available for Manual Installation are listed on each servers' QuickSpecs
Subscriber's Choice

Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides software and driver change notifications for ProLiant products. Sign up at: http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis.

SmartStart Scripting Toolkit (SSSTK) The SmartStart Scripting Toolkit is a server deployment product that delivers an unattended automated installation for high-volume server deployments. The SmartStart Scripting Toolkit includes a set of utilities for configuring and deploying servers in a customized, predictable, and unattended manner. These utilities enable you to duplicate the configuration of a source server on target servers with minimum user interaction.

The Toolkit is designed for IT experts with experience in scripting operating system installations and configuring ProLiant server hardware.

For additional information, please see: http://h18004.www1.hp.com/products/servers/management/toolkit/
index.html
ROMPaq, software and latest drivers

The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options; downloaded from Software and Drivers download pages website at: http://www.hp.com/go/support and from www.hp.com/servers/easysetup. Contains the following:

  • HP Insight Management Agents for Systems Insight Manager (SIM) Integration
  • HP Systems Management Homepage
  • Array Configuration Utility (ACU)
  • Array Diagnostics Utility (ADU)
  • HP Insight Diagnostics

High Performance Clusters

HP Cluster Platforms

HP Cluster Platforms are specifically engineered, factory-integrated large-scale ProLiant clusters optimized for High Performance Computing, with a choice of servers, networks and software. Operating system options include specially priced offerings for Red Hat Enterprise Linux and SUSE Linux Enterprise Server, as well as Microsoft Windows HPC Server. A Cluster Platform Configurator simplifies ordering. http://www.hp.com/go/clusters

HP HPC Interconnects

High Performance Computing (HPC) interconnect technologies are available for this server as part of the HP Cluster Platform portfolio. These high-speed InfiniBand and Gigabit interconnects are fully supported by HP when integrated within an HP cluster. Flexible, validated solutions can be defined with the help of configuration tools. http://www.hp.com/techservers/clusters/ucp/index.html

HP Cluster Management Utility

HP Cluster Management Utility (CMU) is an HP-licensed and HP-supported suite of tools that are used to manage large-scale Linux ProLiant systems. CMU includes software for the centralized provisioning, management and monitoring of nodes. CMU makes the administration of clusters user friendly, efficient, and effective. http://www.hp.com/go/cmu

HP HPC Linux Value Pack

HP HPC Linux Value Pack (Value Pack) is an HP-licensed and HP-supported specially priced software bundle for the development and deployment of applications on HPC Cluster Platforms. Value Pack includes the Platform HPC Enterprise Edition suite of tools including the LSF workload scheduler, the HP-MPI parallelization library. Also included are the HP Unified Parallel C compiler and the HP Shmem library, as well as the execution environments for the libraries and compiler. HP HPC Linux Value Pack


Factory Express Portfolio for Servers and Storage HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed.

Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches.

For more information on Factory Express services for your specific server model please contact your sales representative or go to: http://www.hp.com/go/factory-express.

HP Enterprise Configurator

The HP eConfigure Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. http://www.hp.com/products/configurator

contents
 Overview      Standard Features      Optional Features      Service and Support      Pre-configured Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Service and Support

NOTE: HP Care Pack services are offered at enclosure level only.
Service and Support HP Technology Services for Industry Standard Servers and BladeSystem
Capitalizing on HP ProLiant server and HP BladeSystem capabilities requires a service partner who understands your increasingly complex business technology environment. That's why it makes sense to team up with the people who know HP infrastructure hardware and software best - the experienced professionals at HP Services.

What HP ProLiant and BladeSystem Services can do for you
HP ProLiant and BladeSystem Services can help you design, deploy, test, integrate, support, and manage IT and infrastructure solutions. This way, HP proposes services solutions that include more than just uplift of base warranty. You can get the support you need by choosing from one of a number of service packaged solutions we have designed to address wider set of customer support needs.

HP Technology Services meets business challenges with services offered in three packages - Optimized Care Package, Standard Care Package, and Basic Care Package - available for each product group. Such packaged solutions enable customers to optimize technology operations, minimize risk and drive better business outcomes with easy-to-buy, easy-to-use scalable support packages for servers, storage, networking and software.

Optimized Care Optimized Care Package: Supports maintaining servers at optimum performance availability

HP ProLiant Server Hardware Installation

Provides for the basic hardware installation of HP branded servers, storage devices and networking options to assist you in bringing your new hardware into operation in a timely and professional manner
http://h20195.www2.hp.com/V2/GetPDF.aspx/5981-9356EN

HP Installation and Startup for Insight Control Software
Provides for the deployment and basic configuration of HP Insight Control on HP ProLiant ML and DL series servers or HP BladeSystem servers http://h20195.www2.hp.com/v2/GetPDF.aspx/4AA0-9972ENW.pdf

3-Year HP Critical Advantage
Provides end-to-end infrastructure support solution for business critical applications running on virtualized/x86 infrastructures, enabling the customers to cost effectively build, operate, and continuously improve their IT environment
http://h20195.www2.hp.com/V2/GetDocument.aspx?docname=4AA3-1772ENW

Additional Services
: Data Center Transformation Service

Standard Care Standard Care Package: Package that maintains high level of server availability

HP ProLiant Server Hardware Installation

Provides for the basic hardware installation of HP branded servers, storage devices and networking options to assist you in bringing your new hardware into operation in a timely and professional manner
http://h20195.www2.hp.com/V2/GetPDF.aspx/5981-9356EN

HP Installation and Startup for Insight Control Software
Provides for the deployment and basic configuration of HP Insight Control on HP ProLiant ML and DL series servers or HP BladeSystem servers http://h20195.www2.hp.com/v2/GetPDF.aspx/4AA0-9972ENW.pdf

3-Year HP 6 hour Hardware Support Onsite Call-to-Repair Service
Provides an IT manager with a team of support specialists who will quickly begin troubleshooting the system to help return the hardware to operating condition within 6 hours of the initial service request to the HP Global Solution Center
http://h20195.www2.hp.com/V2/GetPDF.aspx/5982-6547EN.pdf

3-Year , HP 24x7 Software Support for Insight Control
Provides for the deployment and basic configuration of HP Insight Control on HP ProLiant ML and DL series servers or HP BladeSystem servers
http://h20195.www2.hp.com/V2/GetPDF.aspx/5981-6645EEE.pdf

Additional Services
: Software OS (Microsoft, Linux (SUSE/Red Hat) & VMware Installation & Start Up and Software Support); Microsoft or Linux or VMware education courses; +60 Proactive Select Credits

Basic Care

Basic Care Package: delivers minimum recommended support service level

HP ProLiant Server Hardware Installation

Provides for the basic hardware installation of HP branded servers, storage devices and networking options to assist you in bringing your new hardware into operation in a timely and professional manner
http://h20195.www2.hp.com/V2/GetPDF.aspx/5981-9356EN

HP Installation and Startup for Insight Control Software
Provides for the deployment and basic configuration of HP Insight Control on HP ProLiant ML and DL series servers or HP BladeSystem servers http://h20195.www2.hp.com/v2/GetPDF.aspx/4AA0-9972ENW.pdf

3-Year HP 24x7 4 hour Response, Hardware Support Onsite Service
Provides for the deployment and basic configuration of HP Insight Control on HP ProLiant ML and DL series servers or HP BladeSystem servers http://h20195.www2.hp.com/v2/GetPDF.aspx/4AA0-9972ENW.pdf

3-Year , HP 24x7 Software Support for Insight Control
Provides for the deployment and basic configuration of HP Insight Control on HP ProLiant ML and DL series servers or HP BladeSystem servers
http://h20195.www2.hp.com/V2/GetPDF.aspx/5981-6645EEE.pdf

Additional Services
: Software OS (Microsoft, Linux (SUSE/Red Hat) & VMware Installation & Start Up and Software Support); +30 Proactive Select Credits, Factory Express


Insight Remote Support

The packages include HP Insight Remote Support that uses proven technology to deliver secure, reliable 24x7 remote monitoring, diagnoses, and problem resolution. It is available at no additional cost to all warranty, HP Care Pack Service, and service agreement customers.


For more information

To learn more on HP ProLiant servers and HP BladeSystem servers, please contact your HP sales representative or HP Authorized Channel Partner. Or visit: http://www.hp.com/services/proliant

contents
 Overview      Standard Features      Optional Features      Service and Support      Pre-configured Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Pre-configured Models

NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section.
NOTE: Pre-configured models ship with the configurations below. Options can be selected from the Core or Additional options section of this QuickSpecs.
NOTE: HP does not allow factory integration of options into pre-configured models. Any additional options purchased will be shipped separately.
NOTE: If you desire a custom configuration please see "Configuration Information - Factory Integrated Models" section of this QuickSpecs.
Non-Hot Plug Serial ATA (SATA) Model
NOTE: Non-Hot Plug models are not upgradeable to Hot Plug.
NOTE: A rail kit is not included in model - this allows for the purchase of the right size rail kit.
NOTE: This Model includes two HP ProLiant SL170z Server trays. Specs below represent configuration of each tray.
HP ProLiant SL170z G6 2 Trays E5504 6x2GB Rack Server
539611-001
Processor(s) (1) Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)
Cache Memory 4MB (4 x 1MB) shared Level 3 cache
Memory 6GB (3 x 2GB) PC3-10600E (UDIMM)
Network Controller HP NC362i Integrated Dual Port Gigabit Server Adapter
Storage Controller Embedded SATA RAID 0, 1, 10
Hard Drive Optional SATA
Internal Storage Up to 6 large form factor Non-Hot Plug drives/Server tray using Quick Release carrier
Power Supply 750W
Fans 3 system fans ship standard in z6000 chassis
Form Factor One HP ProLiant z6000 G6 Chassis
Two HP ProLiant SL170z G6 Server
Warranty Server Warranty includes 1 year Parts, 1 year Labor, 1-year on-site support with next business day response.
contents
 Overview      Standard Features      Optional Features      Service and Support      Pre-configured Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Configuration Information - Factory Integrated Models

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on configurable product offerings and requirements.
NOTE: Configure-to-order (CTO) servers must start with a CTO Chassis.
NOTE: FIO indicates that this option is only available as a factory installable option.

Step 1: Base Configuration (choose one from each list unless otherwise noted)
HP Chassis HP ProLiant z6000 G6 2U Configure-to-order Chassis
NOTE: Ships with 2U chassis and 3 fans.
538080-B21

HP Server Node

HP ProLiant SL170z G6 Configure-to-order Server
NOTE: It is required that 2 server trays be purchased.
NOTE: Each SL170z tray has 1 system board.
570147-B21

HP Rail Kits

HP ProLiant z6000 G6 1U/2U E-L Servers Rail Kit
NOTE: 2U rail kit used for HP or 3rd part racks - allows addition of one z6000 chassis at a time.
570226-B21
HP ProLiant z6000 G6 5 Shelf 10U Bulk Rail Kit
NOTE: 10U rail kit used for HP racks ONLY - allows addition of five z6000 chassis at a time.
570227-B21

HP Power Supplies

NOTE: Prior to making a power supply selection it is highly recommended that the HP Power Advisor is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at: www.hp.com/go/hppoweradvisor
HP 460W Common Slot Gold Hot Plug Power Supply Kit 503296-B21
HP 460W Common Slot Platinum Hot Plug Power Supply Kit 593188-B21
HP 750W Common Slot Platinum Hot Plug Power Supply Kit 593831-B21
HP 750W Common Slot Gold Hot Plug Power Supply Kit 512327-B21
HP 1200W Common Slot Silver Hot Plug Power Supply Kit 500172-B21
HP 1200W Common Slot Platinum Hot Plug Power Supply Kit 578322-B21

Step 2: Choose Required Server Node Options (only one of the following from each list unless otherwise noted)
HP Processors NOTE: If 2 processors are desired, select one xxxxx-L21 and one xxxxxx-B21.  
Six-Core Processors
HP SL170z G6 Intel® Xeon® X5680 (3.33GHz/6-core/12MB/130W) FIO Processor Kit 592019-L21
HP SL170z G6 Intel® Xeon® X5670 (2.93GHz/6-core/12MB/95W) FIO Processor Kit

592033-L21

HP SL170z G6 Intel® Xeon® X5660 (2.80GHz/6-core/12MB/95W) FIO Processor Kit

592035-L21

HP SL170z G6 Intel® Xeon® X5650 (2.66GHz/6-core/12MB/95W) FIO Processor Kit 592037-L21
Quad-Core Processors  
HP SL170z G6 Intel® Xeon® E5640 (2.66GHz/4-core/12MB/80W) FIO Processor Kit 592044-L21
HP SL170z G6 Intel® Xeon® E5630 (2.53GHz/4-core/12MB/80W) FIO Processor Kit 592040-L21
HP SL170z G6 Intel® Xeon® E5620 (2.40GHz/4-core/12MB/80W) FIO Processor Kit 592042-L21
HP SL170z G6 Intel® Xeon® L5640 (2.26GHz/6-core/12MB/60W) FIO Processor Kit 592051-L21
HP SL170z G6 Intel® Xeon® L5630 (2.13GHz/4-core/12MB/40W) FIO Processor Kit 592059-L21
HP SL170z G6 Intel® Xeon® E5506 (2.13GHz/4-core/4MB/80W) FIO Processor Kit 592047-L21
Dual-Core Processors  
HP SL170z G6 Intel® Xeon® E5503 (2.0GHz/2-core/4MB/80W) FIO Processor Kit 592049-L21
NOTE: HT indicates that the processor model supports Intel® Hyper-Threading Technology.
NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5500 and 5600 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage.
NOTE: Existing SL products cannot be upgraded with 130watt processors, new purchase only
 

HP Memory Registered DIMMs (RDIMMs)  
HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
500656-B21
HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
500658-B21
HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low Power Memory Kit
500660-B21
HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
593339-B21
HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit
NOTE: Low Voltage DIMMs can only be used with Intel® Xeon® processor 5600 series processors.
604504-B21
HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 500662-B21
HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit
NOTE: Low Voltage DIMMs can only be used with Intel® Xeon® processor 5600 series processors.
604506-B21
HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit 500666-B21
Unbuffered with ECC DIMMs (UDIMMs)
NOTE: Maximum 12 DIMMs supported per node
HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit 500668-B21
HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit 500670-B21
HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit 500672-B21
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient
NOTE: There is a maximum support limitation of 8 ranks per memory channel (maximum of 2 quad rank DIMMs per channel)
NOTE: PC3L is a low voltage memory

Step 3: Choose Additional Factory Integratable Options
HP Storage Controllers HP Smart Array P212/256 BBWC 1-ports Int/1-ports Ext PCIe x8 FIO SAS Controller
NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller (574001-B21)
NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21)
491191-B21
HP Smart Array P410/ZM 2-ports Int PCIe x8 FIO SAS Controller
NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller (583997-B21)
462860-B21
HP Smart Array P410/256 BBWC 2-ports Int PCIe x8 FIO SAS Controller
NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller (583997-B21)
NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21)
491195-B21
HP Smart Array P411/256 BBWC 2-ports Ext PCIe x8 FIO SAS Controller
NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21)
491193-B21

HP Insight Software HP Insight Control for Linux including 1yr 24x7 Support ML/DL Bundle 1 Server FIO License TC203A

Step 4: Choose Additional Options for Factory Integration
NOTE: For additional options, please refer to the "Core Options" and "Additional Options" section below.
contents
 Overview      Standard Features      Optional Features      Service and Support      Pre-configured Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Core Options

NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for additional information.
HP Unique Options HP SL160/170 G6 x16 Input/Output Riser Kit 574806-B21
HP z6000 P212 SAS 4 Hard Drive Power Cable Kit
NOTE: This is required when adding SAS hard drives using the P212 controller.
574001-B21
HP z6000 P410 SAS 4 Hard Drive Power Cable Kit
NOTE: This is required when adding SAS hard drives using the P410 controller.
583997-B21

HP z6000 Battery Back Write Cache Hardware Kit
NOTE: This is required when adding BBWC.

582653-B21

HP z6000 Small Form Factor 2 Drive Cage Kit
NOTE: This is required when adding SFF (2.5") SSD or hard drives.
582657-B21

HP Processor Six-Core Processors  
HP SL170z G6 Intel® Xeon® X5680 (3.33GHz/6-core/12MB/130W) Processor Kit 592019-B21
HP SL170z G6 Intel® Xeon® X5670 (2.93GHz/6-core/12MB/95W) Processor Kit

592033-B21

HP SL170z G6 Intel® Xeon® X5660 (2.80GHz/6-core/12MB/95W) Processor Kit

592035-B21

HP SL170z G6 Intel® Xeon® X5650 (2.66GHz/6-core/12MB/95W) Processor Kit

592037-B21

Quad-Core Processors  
HP SL170z G6 Intel® Xeon® E5640 (2.66GHz/4-core/12MB/80W) Processor Kit 592044-B21
HP SL170z G6 Intel® Xeon® E5630 (2.53GHz/4-core/12MB/80W) Processor Kit 592040-B21
HP SL170z G6 Intel® Xeon® E5620 (2.40GHz/4-core/12MB/80W) Processor Kit 592042-B21
HP SL170z G6 Intel® Xeon® L5640 (2.26GHz/6-core/12MB/60W) Processor Kit 592051-B21
HP SL170z G6 Intel® Xeon® L5630 (2.13GHz/4-core/12MB/40W) Processor Kit 592059-B21
HP SL170z G6 Intel® Xeon® X5570 (2.93GHz/4-core/8MB/95W) Processor Kit 539252-B21
HP SL170z G6 Intel® Xeon® X5560 (2.80GHz/4-core/8MB/95W) Processor Kit 588191-B21
HP SL170z G6 Intel® Xeon® X5550 (2.66GHz/4-core/8MB/95W) Processor Kit 539254-B21
HP SL170z G6 Intel® Xeon® E5540 (2.53GHz/4-core/8MB/80W) Processor Kit

539256-B21

HP SL170z G6 Intel® Xeon® E5520 (2.26GHz/4-core/8MB/80W) Processor Kit 539260-B21
HP SL170z G6 Intel® Xeon® E5506 (2.13GHz/4-core/4MB/80W) Processor Kit 592047-B21
HP SL170z G6 Intel® Xeon® E5504 (2.00GHz/4-core/4MB/80W) Processor Kit

539266-B21

HP SL170z G6 Intel® Xeon® L5530 (2.40GHz/4-core/8MB/60W) Processor Kit 586601-B21
HP SL170z G6 Intel® Xeon® L5520 (2.26GHz/4-core/8MB/60W) Processor Kit

571698-B21

HP SL170z G6 Intel® Xeon® L5506 (2.13GHz/4-core/4MB/60W) Processor Kit
571703-B21
Dual-Core Processors  
HP SL170z G6 Intel® Xeon® E5503 (2.0GHz/2-core/4MB/80W) Processor Kit 592049-B21
HP SL170z G6 Intel® Xeon® E5502 (1.86GHz/2-core/4MB/80W) Processor Kit
571705-B21
NOTE: HT indicates that the processor model supports Intel® Hyper-Threading Technology.
NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5500 and 5600 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage.
 

HP Memory

Registered DIMMs (RDIMMs)  
HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
500656-B21
HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
500658-B21
HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low Power Memory Kit 500660-B21
HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 593339-B21
HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit
NOTE: Low Voltage DIMMs can only be used with Intel® Xeon® processor 5600 series processors.
604504-B21
HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 500662-B21
HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit
NOTE: Low Voltage DIMMs can only be used with Intel® Xeon® processor 5600 series processors.
604506-B21
HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit 500666-B21
Unbuffered with ECC DIMMs (UDIMMs)
NOTE: Maximum 12 DIMMs supported per node
 
HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit 500668-B21
HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit 500670-B21
HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit 500672-B21
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient
 
NOTE: There is a maximum support limitation of 8 ranks per memory channel (maximum of 2 quad rank DIMMs per channel)
NOTE: PC3L is a low voltage memory.

HP Hard Drives NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Hard drives have either a one year or three year warranty.
NOTE: The hard drives use a quick release carrier.
NOTE: One 2 Drive SFF Drive Cage (582657-B21) is required when installing 2 SFF drives.
NOTE: When adding SAS one of the following cable kits needs to be ordered depending on which SAS controller installing - HP P212 SAS 4HDD Cable Kit 574001-B21.
 
SAS Non-Hot Plug LFF (3.5-inch) Enterprise (ENT) Drives - with quick-release (QR) carrier  
HP 600GB 6G SAS 15K rpm LFF (3.5-inch) Quick-release Dual Port Enterprise 3yr Warranty Hard Drive 574758-B21
HP 300GB 6G SAS 15K rpm LFF (3.5-inch) Quick-release Dual Port Enterprise 3yr Warranty Hard Drive 585980-B21
SAS Non-Hot Plug SFF (2.5-inch) Enterprise (ENT) Drives - with quick-release (QR) carrier  
HP 300GB 6G SAS 10K rpm SFF (2.5-inch) Quick-release Dual Port Enterprise 3yr Warranty Hard Drive 574879-B21
SAS Non-Hot Plug LFF (3.5-inch) Midline (MDL) Drives - with quick-release (QR) carrier  
HP 2TB 6G SAS 7.2K rpm LFF (3.5-inch) Quick-release Dual Port Midline 1yr Warranty Hard Drive 574761-B21
SATA Non-Hot Plug LFF (3.5-inch) Entry (ETY) Drives - with quick-release (QR) carrier  
HP 160GB 3G SATA 7.2K rpm LFF (3.5-inch) Quick-release Entry 1yr Warranty Hard Drive 574021-B21
SATA Non-Hot Plug LFF (3.5-inch) Midline (MDL) Drives - with quick-release (QR) carrier  
HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch) Quick-release Midline 1yr Warranty Hard Drive 574755-B21
HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch) Quick-release Midline 1yr Warranty Hard Drive 574025-B21
HP 500GB 3G SATA 7.2K rpm LFF (3.5-inch) Quick-release Midline 1yr Warranty Hard Drive 574023-B21
SATA Non-Hot Plug SFF (2.5-inch) Midline (MDL) Drives - with quick-release (QR) carrier  
HP 500GB 3G SATA 7.2K rpm SFF (2.5-inch) Quick-release Midline 1yr Warranty Hard Drive 574953-B21
SATA Non-Hot Plug Midline (MDL) Solid State Drives - with quick-release (QR) carrier  
HP 120GB 3G SATA SFF (2.5-inch) Quick-release Midline 1yr Warranty Solid State Drive 586587-B21
HP 60GB 3G SATA SFF (2.5-inch) Quick-release Midline 1yr Warranty Solid State Drive 586585-B21

HP Networking Gigabit Ethernet Adapters  
HP NC112T PCI Express Gigabit Server Adapter 503746-B21
HP NC360T PCI-E Dual Port Gigabit Server Adapter 412648-B21
HP NC364T PCI-E Quad Port Gigabit Server Adapter 435508-B21
HP NC365T 4-port Ethernet Server Adapter 593722-B21
HP NC373F PCI-E Multifunction 1000SX Gigabit Svr Adapter 394793-B21
HP NC373T PCI-E Multifunction Gigabit Server Adapter 394791-B21
HP NC375T PCI Express Quad Port Gigabit Server Adapter 538696-B21
HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter 458492-B21
10 Gigabit Ethernet Adapters
NOTE: A minimum of two Gigabytes (2 GB) of server memory is required per each NC522SFP adapter.
NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately.
 
HP NC522SFP Dual Port 10GbE Gigabit Server Adapter 468332-B21
HP NC523SFP 10Gb 2-port Server Adapter 593717-B21
HP NC550SFP Dual Port 10GbE Server Adapter 581201-B21
HP NC552SFP 10Gb 2-port Ethernet Server Adapter 614203-B21
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs.  

HP InfiniBand HP InfiniBand 4X DDR PCI-E 0 Memory Dual Port HCA
483513-B21
HP InfiniBand 4X DDR PCI-E Dual Port HCA 448397-B21
HP InfiniBand 4X QDR ConnectX-2 PCIe G2 Dual Port HCA 592520-B21
HP InfiniBand 4X DDR ConnectX-2 PCIe G2 Dual Port HCA 592521-B21
QLogic InfiniBand 4X QDR PCI-E G2 Dual Port HCA 583211-B21
NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13078_na/13078_na.html  

HP I/O Expansion Options HP SL160/170 G6 x16 Input/Output Riser Kit
574806-B21

HP Power Supplies NOTE: Prior to making a power supply selection it is highly recommended that the HP Power Advisor is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at: www.hp.com/go/hppoweradvisor
CAUTION: In ProLiant Servers that have more than one power slot (bay), only same size power supplies are recommended. If non-matched power supplies are inserted you will get errors and operation will fail.
HP 460W Common Slot Gold Hot Plug Power Supply Kit 503296-B21
HP 460W Common Slot Platinum Hot Plug Power Supply Kit 593188-B21
HP 750W Common Slot Platinum Hot Plug Power Supply Kit 593831-B21
HP 750W Common Slot Gold Hot Plug Power Supply Kit 512327-B21
HP 1200W Common Slot Silver Hot Plug Power Supply Kit 500172-B21
HP 1200W Common Slot Platinum Hot Plug Power Supply Kit 578322-B21
NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables.  
contents
 Overview      Standard Features      Optional Features      Service and Support      Pre-configured Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Additional Options

NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for additional information.
HP Insight Software HP Insight Control for Linux  
HP Insight Control for Linux including 1yr 24x7 Support Electronic License
TC213AAE
HP Insight Control for Linux including 1yr 24x7 Support Single Server License TC209A
HP Insight Control for Linux Media Kit
NOTE: Media pack DVD contains the ISO image for HP Insight Control for Linux, HP Systems Insight Manager, HP Insight Control power management, HP Insight Control virtual machine management, and an integrated installer. Servers must be acquired separately.
TC208A
NOTE: Licenses ship without media. The Media Kit for Insight Control for Linux can be ordered separately, or can be downloaded at: http://www.hp.com/go/ic-linux (click on Download button).
NOTE: Electronic and Flexible-Quantity licenses can be used to purchase multiple licenses with a single set of activation keys.
NOTE: For additional License Kits, including electronic licensing options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_na/13019_na.html
 

High Performance Clusters HP Cluster Management Utility  
HP Cluster Management Utility Flexible License
NOTE: This part number can be used to purchase one certificate for multiple licenses with a single activation key. Each license is for one node (server). Customer will receive a printed end user license agreement and license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online in order to obtain a license key.
QL803A
HP Cluster Management Utility Media
NOTE: Order a minimum of one license per cluster to purchase media including software and documentation, which will be delivered to the customer, and also licenses CMU management. No license key is delivered or required.
433257-B21
NOTE: For additional license kits please see the QuickSpecs at: http://h18004.www1.hp.com/products/quickspecs/12612_na/12612_na.html  
HP HPC Linux Value Pack  
HP High Performance Computing Linux Value Pack 1 Processor Flexible License
NOTE: This part number can be used to purchase one certificate for multiple licenses with a single activation key. Each license is for one socket (a.k.a. processor). Customer will receive a printed end user license agreement and license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online in order to obtain a license key.
TC293B
HP High Performance Computing Linux Value Pack Media Kit
NOTE: This part number can be used to purchase media including software and documentation, which will be delivered to the customer.
TC294A
NOTE: For additional license kits please see the QuickSpecs at: http://h18004.www1.hp.com/products/quickspecs/13485_na/13485_na.html  

HP Rail Options HP SL Universal Switch Rail Kit
NOTE: This kit allows you to install HP or 3rd party switch in the same rack as SL6000.
592774-B21

HP I/O Accelerator Options HP 640GB Multi Level Cell PCIe ioDrive Duo for ProLiant Servers
600282-B21
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13587_na/13587_na.html
 

HP Security HP Trusted Platform Module Option
488069-B21
NOTE: The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to authenticate the server platform. These artifacts can include passwords, certificates and encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user data and to ensure that a server running Windows Server 2008 has not been tampered with while the system was offline. For more information about TPM, including a white paper, go to: www.hp.com/go/TPM.
NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment.
NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing the key could result in data loss.
 

HP Storage Controllers SAS Controllers
Smart Array P212 Controller
NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller (574001-B21).
 
HP Smart Array P212/ZM 1-ports Int/1-ports Ext PCIe x8 SAS Controller 462828-B21
HP Smart Array P212/256 1-ports Int/1-ports Ext PCIe x8 SAS Controller 462834-B21
Smart Array P410 Controller
NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller (583997-B21)
 
HP Smart Array P410/256 2-ports Int PCIe x8 SAS Controller 462862-B21
HP Smart Array P410/512 BBWC 2-ports Int PCIe x8 SAS Controller 462864-B21
HP Smart Array P410/512 FBWC 2-ports Int PCIe x8 SAS Controller 578230-B21
HP Smart Array P410/1G FBWC 2-ports Int PCIe x8 SAS Controller 572532-B21
Smart Array P411 Controller  
HP Smart Array P411/256 2-ports Ext PCIe x8 SAS Controller 462830-B21
HP Smart Array P411/512 BBWC 2-ports Ext PCIe x8 SAS Controller 462832-B21
HP Smart Array P411/512 FBWC 2-ports Ext PCIe x8 SAS Controller 578229-B21
HP Smart Array P411/1G FBWC 2-ports Ext PCIe x8 SAS Controller 572531-B21
Optional Upgrades
NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21).
 
HP 256MB P-series Cache Upgrade
NOTE: Supported on HP Smart Array P212 Controller only.
462968-B21
HP 512MB P-Series Battery Backed Write Cache Upgrade
NOTE: Supported on HP Smart Array P410 Controller and HP Smart Array P411 Controller only.
462967-B21
HP 650 mAh P-Series Battery
NOTE: To enable BBWC on the 256MB cache.
NOTE: Supported on HP Smart Array P212 Controller.
462969-B21
HP 1GB Flash Backed Cache 534562-B21
HP Smart Array Advanced Pack including 1yr 24x7 Technical Support and Updates Single Server License
NOTE: This part number can be used to purchase a single license or to order multiple licenses with a single activation key. Customers will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Include one year of 24x7 HP Software Technical Support Services.
516471-B21
HP Smart Array Hot Plug Advance Pack for B110i w/1y 24x7 Supp Physical 1 Svr LTU TC421A
NOTE: Please see the following QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13203_na/13203_na.html
(Smart Array P212 Controller)
http://h18000.www1.hp.com/products/quickspecs/13201_na/13201_na.html
(Smart Array P410 Controller)
http://h18000.www1.hp.com/products/quickspecs/13202_na/13202_na.html
(Smart Array P411 Controller)
http://h18000.www1.hp.com/products/quickspecs/13200_na/13200_na.html
(Smart Array Advanced Pack)
http://h18000.www1.hp.com/products/quickspecs/13495_na/13495_na.html
(Smart Array Hot Plug Advance Pack for B110i)
 
SCSI HBA  
HP SC11Xe Ultra320 Single Channel/ PCIe x4 SCSI Host Bus Adapter
NOTE: Recommended HBA for SCSI tape drive connect.
412911-B21
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12566_na/12566_na.html
(SCSI HBA)
 

HP Storage Options Fibre Channel HBA  
NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows and Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html  
Emulex Fibre Channel HBAs  
HP 81E 8Gb Single Port PCI-e Fibre Channel Host Bus Adapter AJ762A
HP 82E 8Gb Dual Port PCI-e Fibre Channel Host Bus Adapter AJ763A
HP FC2142SR 4Gb PCIe Host Bus Adapter A8002A
HP FC2242SR 4Gb PCIe DC Host Bus Adapter A8003A
QLogic Fibre Channel HBAs  
HP 81Q PCI-e Fibre Channel Host Bus Adapter AK344A
HP 82Q 8Gb Dual Port PCI-e Fibre Channel Host Bus Adapter AJ764A
HP FC1142SR 4Gb PCIe Host Bus Adapter AE311A
HP FC1242SR 4Gb PCIe DC Host Bus Adapter AE312A
Storage SCSI HBA  
HP U320e SCSI Dual Channel Host Bus Adapter
NOTE: Recommended HBA for MSL SCSI Tape Library connect.
AH627A
Converged Network Adapter  
HP CN1100E Dual Port Converged Network Adapter BK835A

HP Disk Storage Systems Disk Enclosures
HP D2600 Disk Enclosure
AJ940A
HP D2700 Disk Enclosure
AJ941A
NOTE: Please see the QuickSpecs for additional options and configuration information at:
http://h18000.www1.hp.com/products/quickspecs/13404_na/13404_na.html

HP SL Advanced Power Manager NOTE: The SL Advanced Power Manager is an optional rack level solution for the HP ProLiant SL6000 which enables server-level DC (or hardware) power on and off and server-level monitoring. In addition, the SL APM will automatically discover SL hardware components which are connected into the SL APM solution.

NOTE: The SL APM does not replace rack PDUs, but is designed to enable the utilization of basic, low cost, rack PDUs while providing the functionality of 'switched' PDUs which provide hardware power on/off of individual servers by turning off the AC power to the power supplies of a given server. Because the SL servers share power supplies to optimize power efficiency, using 'switched' PDUs to turn off the power supplies in the chassis will result in the loss of all servers in that chassis. The SL APM solves this by allowing server-level hardware power on/off of the DC power to the individual server motherboards.
HP SL Advanced Power Manager Kit
538084-B21
HP SL Advanced Power Manager Distribution Module Kit
NOTE: Connects up to 10 chassis.
539264-B21
HP SL RJ45 Advanced Power Manager Option Module Kit
NOTE: 1 per SL APM Distribution module.
580212-B21
NOTE: Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords.

HP Rack Series HP Rack 10000 G2 Series (Carbon/Graphite Metallic)  
HP 10642 G2 Pallet Universal Rack AF001A
HP 10642 G2 Shock Universal Rack AF002A
HP 10642 G2 1200mm deep Shock Rack AF092A
HP 10647 G2 1200mm deep Shock Rack AF094A
NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed.  
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html
 
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower.  

NOTE: HP ProLiant SL170z G6 models have two different rail kits to choose from:

  • 10U bulk rail kit - Used to fit in HP 10000 series racks
    • One 10U bulk rail kit will hold up to five z6000 chassis, thus ten SL170z G6 server trays
  • 2U rail kit - Used to fit in 3rd party racks or to sell one z6000 chassis at a time
    • One 2U rail kit will hold one z6000 chassis, thus two SL170z servers

For additional information, please visit: www.hp.com/go/rackandpower.

 
NOTE: The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation). Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm).
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.
 
NOTE: Quick deploy rail system provides tool-free support for racks with square or round mounting holes (including Compaq/HP 7000, 9000, 10000 G2 and HP series), with an adjustment range of 24" - 36". The ambidextrous cable management arm can be mounted on either the left or right side for improved cable management.
NOTE: Cable management arm must be removed to access hot-plug power supplies when the cable management arm is mounted on the right.
 

HP USB and SD Options HP USB 2-Button Optical Scroll Mouse DC172B
HP USB 04 Standard Keyboard DT528A#ABA

HP Care Pack Services Hardware Services 4-Hour On-site Service
HP 3 year 4 hour 24x7 ProLiant DL14x and DL16x Hardware Support U9510E
Hardware Services Next Business Day On-Site Service  
HP 3 year Next business day ProLiant DL14x and DL16x Hardware Support U9508E
Hardware Services 6-Hour Call to Repair On-Site Service  
HP Install ProLiant DL14x and DL16x Service U9520E
LO100i Advanced Pack  
HP 3 year 24x7 Lights Out 100i Advanced Pack Software Support UM748E
NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack.
contents
 Overview      Standard Features      Optional Features      Service and Support      Pre-configured Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Memory

HP ProLiant SL170z G6 Server
NOTE: Memory configurations listed do not apply to "Factory Integrated Models".
NOTE: Chart does not represent all possible memory configurations.
DDR3 memory population guidelines

For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator

Some DIMM installation guidelines are summarized below:

  • For servers with sixteen (16) memory slots
  • There are three (3) channels per processor; six (6) channels per server
  • There are two (3) DIMM slots for two memory channels and one (2) DIMM slots for one memory channel; sixteen (16) total slots
  • Memory channels 1 and 2 consists of the six (6) DIMMs that are furthest from the processor
  • Memory channel 3 consists of the two (2) DIMMs that are closest to the processor
  • DIMM slots that are white should be populated first
  • Do not mix Unbuffered memory (UDIMMs) with Registered memory (RDIMMs)
  • Do not install DIMMs if the corresponding processor is not installed
  • If only one processor is installed in a 2CPU system, only half of the DIMM slots are available
  • To maximize performance, balance the total memory capacity between all installed processors
  • It is not required, but it is recommended to load the channels similarly if possible
  • You can only have up to eight (8) ranks installed per channel
  • You can only install two quad-rank DIMMs per channel
  • You can only install two UDIMMs per channel; if available, the third slot in the channel must remain empty
  • Populate DIMMs from heaviest load (quad-rank) to lightest load (single-rank) within a channel
  • Heaviest load (DIMM with most ranks) within a channel goes furthest from the chipset
  • For memory mirroring mode, channel 3 must be unpopulated. Channels 1 and 2 are populated identically
  • For lock-step mode, channel 3 must be unpopulated. DIMMs in channels 1 and 2 will be installed in pairs. The paired slots will be 1,4; 2,5; 3;6 on a 3DPC system or 1,4; 2,5; on a 2DPC system
  • If mixing DIMM voltage is a requirement, please note that the DIMMs will run at 1.5V since all 1.35V are capable of supporting 1.5V operations
 
DIMM slot/capacity/populated speed table
DIMM Type -> Registered DIMMs (RDIMMs) Unbuffered with ECC DIMMs (UDIMMs)
DIMM Rank -> Single Rank (1R) Dual Rank (2R) Quad Rank (4R) Single Rank (1R) Dual Rank (2R)
DIMM Capacity -> 4GB
2GB 4GB 8GB 8GB 4GB 16GB 1GB 2GB 4GB
DIMM Native Speed (MHz) -> 1333
1333 1333 1066 1333 1066 1066 1333 1333 1333
                     
SLOTS THAT CAN BE POPULATED
18 slot servers 16 16 16 16 16 12 12 12 12 12
                     
MAXIMUM CAPACITY (GB)
  64 32 64 128 128 48 192 12 24 48
                     
POPULATED DIMM SPEED (MHz)
1 DIMM Per Channel 1333
1333
1333
1066 1333
1066 1066 1333 1333 1333
2 DIMMs Per Channel 1333*
1333*
1333*
1066 1333*
800 800 1333 1333 1333*
3 DIMMs Per Channel (on 2 channels) 800 800 800 800 800

N/A

N/A

N/A N/A N/A
* Supported at 1333 via setting in ROM based setup utility (RBSU)

NOTES:

  • PC3-10600 DIMMs have a maximum speed of 1333MHz. PC3-8500 DIMMs have a maximum speed of 1066MHz
  • Mixing DIMM speeds is allowed, but the system processor speed rules always override the DIMM capabilities
  • If you do mix DIMM speeds, the memory bus will default to the minimum clock rate of all DIMMs in the system - even if the slower DIMM is on the other processor
  • If you install 1x 1066MHz DIMM in channel 1 and 1x 1333MHz DIMM in channel 2, the maximum speed will be 1066MHz If you install 1x 1066MHz DIMM in channel 1 and 5x 1333MHz DIMMs with 1 DIMM Per Channel (DPC) in each of the other channels, the maximum speed will be 1066MHz
  • If you install 3DPC in one channel (if applicable) and 1DPC in all other channels, you run at 800MHz
  • Maximum memory speed will also depend on the processor installed
    References to the above MHz speeds are for the various speeds of DDR3 DIMMs; 1333 refers to DDR3-1333, etc.

DIMM slot and configuration diagrams
Basic memory slot & population diagram

  • Population order; start with "A" first, "B" second, "C" third, etc.
16 DIMM SLOTS (8 per CPU node)
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11A1AChnl 1
2D2D
3G3G
      
Chnl 24B4BChnl 2
5E5E
6H6H
      
Chnl 37C7CChnl 3
8F8F
 

Standard memory configuration (1 CPU model)

  • 6GB, consisting of three (3) 2GB dual-rank PC3-10600E UDIMMs
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11 A; 2GB DIMM 1A; emptyChnl 1
2 D; empty 2D; empty
3G; empty3G; empty
      
Chnl 24 B; 2GB DIMM 4B; emptyChnl 2
5 E; empty 5E; empty
6H; empty6H; empty
      
Chnl 37C; 2GB DIMM7C; emptyChnl 3
8F; empty8F; empty
 

Standard memory plus optional memory (1 CPU model)

  • 12GB, consisting of three (3) 2GB UDIMMs plus three (3) 2GB UDIMMs
    • 6x 2GB dual-rank PC3-10600E UDIMMs
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11 A; 2GB DIMM 1A; emptyChnl 1
2 D; 2GB DIMM 2D; empty
3G; empty3G; empty
      
Chnl 24 B; 2GB DIMM 4B; emptyChnl 2
5 E; 2GB DIMM 5E; empty
6H; empty6H; empty
      
Chnl 37C; 2GB DIMM7C; emptyChnl 3
8F; 2GB DIMM8F; empty
 

Standard memory replaced with optional memory (1 CPU model)
RDIMM maximum configuration

  • 96GB, consisting of eight (6) 16GB dual-rank PC3-8500 RDIMMs
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11 A; 16GB DIMM
1A; emptyChnl 1
2 D; 16GB DIMM
2D; empty
3 G; empty
3G; empty
      
Chnl 24 B; 16GB DIMM
4B; emptyChnl 2
5 E; 16GB DIMM
5E; empty
6 H; empty
6H; empty
      
Chnl 37 C; 16GB DIMM
7C; emptyChnl 3
8 F; 16GB DIMM 8F; empty
 

Standard memory replaced with optional memory (2 CPU model)
RDIMM maximum configuration

  • 192GB, consisting of twelve (12) 16GB PC3-8500 RDIMMs
  CPU1 CPU2  
  slot # population order slot # population order  
Chnl 1 1 A; 16GB DIMM
1 A; 16GB DIMM
Chnl 1
2 D; 16GB DIMM
2 D; 16GB DIMM
3 G; Empty
3 G; Empty
           
Chnl 2 4 B; 16GB DIMM
4 B; 16GB DIMM
Chnl 2
5 E; 16GB DIMM
5 E; 16GB DIMM
6 H; empty
6 H; empty
           
Chnl 3 7 C; 16GB DIMM
7 C; 16GB DIMM
Chnl 3
8 F; 16GB DIMM 8 F; 16GB DIMM
 

UDIMM maximum configuration

  • 48GB, consisting of twelve (12) 4GB dual-rank PC3-10600 UDIMMs
  CPU1 CPU2  
  slot # population order slot # population order  
Chnl 1 1 A; 4GB DIMM 1 A; 4GB DIMM Chnl 1
2 D; 4GB DIMM 2 D; 4GB DIMM
3 G; empty 3 G; empty
           
Chnl 2 4

B; 4GB DIMM

4

B; 4GB DIMM

Chnl 2
5

E; 4GB DIMM

5

E; 4GB DIMM

6

H; empty

6

H; empty

           
Chnl 3 7 C; 4GB DIMM 7 C; 4GB DIMM Chnl 3
8 F; 4GB DIMM 8 F; 4GB DIMM
 

NOTE: Capacity references are rounded to the common Gigabyte values.

  • 1GB = 1024MB
  • 2GB = 2048MB
  • 4GB = 4096MB
  • 8GB = 8192MB
  • 16GB = 16384MB

DDR3 memory options part number decoder
 

Following are memory options available from HP:

HP Memory Registered DIMMs (RDIMMs)  
HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
500656-B21
HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
500658-B21
HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low Power Memory Kit 500660-B21
HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 593339-B21
HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit
NOTE: Low Voltage DIMMs can only be used with Intel® Xeon® processor 5600 series processors.
604504-B21
HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 500662-B21
HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit
NOTE: Low Voltage DIMMs can only be used with Intel® Xeon® processor 5600 series processors.
604506-B21
HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit 500666-B21
Unbuffered with ECC DIMMs (UDIMMs)
NOTE: Maximum 12 DIMMs supported per node
 
HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit 500668-B21
HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit 500670-B21
HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit 500672-B21
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient
 
NOTE: There is a maximum support limitation of 8 ranks per memory channel (maximum of 2 quad rank DIMMs per channel)
NOTE: PC3L is a low voltage memory
contents
 Overview      Standard Features      Optional Features      Service and Support      Pre-configured Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Storage

1-6 Six 3.5" Non-hot plug SATA hard drive bays - Using quick release carrier
  

Drive Support


Hard Drives
NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Hard drives have either a one year or three year warranty.

SAS Non-Hot Plug LFF (3.5-inch) Enterprise (ENT) Drives - with quick-release (QR) carrier
 

Quantity
Supported

Position
Supported


Controller

600GB 6G SAS 10K
300GB 6G SAS 10K
Up to 6
1-6
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller.
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller.

SAS Non-Hot Plug SFF (2.5-inch) Enterprise (ENT) Drives - with quick-release (QR) carrier
  Quantity
Supported
Position
Supported
Controller
300GB 6G SAS 10K Up to 8 1-8 HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller.
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller.

SAS Non-Hot Plug LFF (3.5-inch) Midline (MDL) Drives - with quick-release (QR) carrier
  Quantity
Supported
Position
Supported
Controller
2TB 6G SAS 7.2K Up to 6 1-6 HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller.
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller.

SATA Non-Hot Plug LFF (3.5-inch) Entry (ETY) Drives - with quick-release (QR) carrier
  Quantity
Supported
Position
Supported
Controller
160GB 3G SATA 7.2K Up to 6 1-6 HP Embedded SATA RAID Controller
NOTE: Transfer rate: 3 Gb/s SATA

SATA Non-Hot Plug LFF (3.5-inch) Midline (MDL) Drives - with quick-release (QR) carrier
  Quantity
Supported
Position
Supported
Controller
2TB 3G SATA 7.2K
1TB 3G SATA 7.2K
500GB 3G SATA 7.2K
Up to 6 1-6 HP Embedded SATA RAID Controller
NOTE: Transfer rate: 3 Gb/s SATA

SATA Non-Hot Plug SFF (2.5-inch) Midline (MDL) Drives - with quick-release (QR) carrier
  Quantity
Supported
Position
Supported
Controller
500GB 3G SATA 7.2K Up to 8 1-8 HP Embedded SATA RAID Controller
NOTE: Transfer rate: 3 Gb/s SATA

SATA Non-Hot Plug Midline (MDL) Solid State Drives - with quick-release (QR) carrier
  Quantity
Supported
Position
Supported
Controller
120GB 3G SATA
60GB 3G SATA
Up to 8 1-8 HP Embedded SATA RAID Controller for up to 6
NOTE: Transfer rate: 3 Gb/s SATA
HP Smart Array P410/256 MB Controller for up to 8

External Storage
  Quantity
Supported
Position
Supported
Controller
D2600 Disk Enclosure Up to 4 External HP Smart Array P212/256 MB Controller
Up to 8   HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB Controller
contents
 Overview      Standard Features      Optional Features      Service and Support      Pre-configured Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Power Specifications

HP 460W Common Slot Platinum Hot Plug Power Supply Kit
Part Number 593188-B21
Input Voltage Range ( V rms ) 100 to 240
Frequency Range (Nominal) ( Hz ) 50/60
Nominal Input Voltage ( Vrms )
100
120
200
208
220
230
240
Maximum Rated Output Wattage Rating
460
460
460
460
460
460
460
Nominal Input Current ( A rms )
5.3
4.3
2.5
2.4
2.3
2.2
2.1
Maximum Rated Input Wattage Rating ( Watts )
512
505
493
493
492
492
491
Maximum Rated VA ( Volt-Amp )
526
518
506
506
505
505
504
Efficiency ( % )
89.8
91.2
93.2
93.3
93.5
93.6
93.6
Power Factor 0.985
Leakage Current ( mA )
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Maximum Inrush Current ( A peak ) 30
Maximum Inrush Current duration ( mS ) 20
Maximum British Thermal Unit Rating ( BTU-Hr )
1747
1722
1683
1682
1679
1678
1677
 
HP 460W Common Slot Gold Hot Plug Power Supply Kit 503296-B21
Input Voltage Range (Vrms) 100 to 240
Frequency Range (Nominal) (Hz) 50/60
Nominal Input Voltage (Vrms)
100
120
200
208
220
230
240
Maximum Rated Output Wattage
460
460
460
460
460
460
460
Nominal Input Current (A rms)
5.5
4.5
2.6
2.5
2.4
2.3
2.2
Max Rated Input Wattage Rating (Watts)
526
520
505
505
503
503
503
Max. Rated VA (Volt-Amp)
548
542
527
527
524
524
524
Efficiency (%) at Max. Rated Output Wattage
87.5
88.5
91
91
91.5
91.5
91.5
Power Factor
0.97
0.97
0.97
0.97
0.97
0.97
0.97
Leakage Current (mA)
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Max. Inrush Current (A peak)
30
30
30
30
30
30
30
Max. Inrush Current duration (mS)
20
20
20
20
20
20
20
Maximum British Thermal Unit Rating (BTU-Hr)
1794
1773
1725
1725
1715
1715
1715
 
HP 750W Common Slot Platinum Hot Plug Power Supply Kit
Part Number 593831-B21
Input Voltage Range ( V rms ) 100 to 240
Frequency Range (Nominal) ( Hz ) 50/60
Nominal Input Voltage ( Vrms )
100
120
200
208
220
230
240
Maximum Rated Output Wattage Rating
750
750
750
750
750
750
750
Nominal Input Current ( A rms )
8.6
7.1
4.2
4.0
3.8
3.6
3.4
Maximum Rated Input Wattage Rating ( Watts )
841
828
809
808
807
806
805
Maximum Rated VA ( Volt-Amp )
863
850
830
829
828
827
826
Efficiency ( % )
89.2
90.6
92.7
92.8
93
93.1
93.2
Power Factor 0.985
Leakage Current ( mA )
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Maximum Inrush Current ( A peak ) 30
Maximum Inrush Current duration ( mS ) 20
Maximum British Thermal Unit Rating ( BTU-Hr )
2868
2825
2761
2757
2753
2749
2747
 
HP 750W Common Slot Gold Hot Plug Power Supply Kit 512327-B21
Input Voltage Range (Vrms) 100 to 240
Frequency Range (Nominal) (Hz) 50/60
Nominal Input Voltage (Vrms) 100 120 200 208 220 230 240
Maximum Rated Output Wattage 750 750 750 750 750 750 750
Nominal Input Current (A rms) 8.9 7.4 4.3 4.1 3.9 3.7 3.6
Max Rated Input Wattage Rating (Watts) 857 847 824 825 820 820 820
Max. Rated VA (Volt-Amp) 894 884 859 859 854 854 854
Efficiency (%) at Max. Rated Output Wattage 87.5 88.5 91 91 91.5 91.5 91.5
Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97
Leakage Current (mA) 0.42 0.50 0.83 0.87 0.92 0.96 1.00
Max. Inrush Current (A peak) 30 30 30 30 30 30 30
Max. Inrush Current duration (mS) 20 20 20 20 20 20 20
Maximum British Thermal Unit Rating (BTU-Hr) 2925 2892 2812 2812 2797 2797 2797
 
HP 1200W Common Slot Platinum Hot Plug Power Supply Kit
Part Number 578322-B21
Input Voltage Range ( V rms ) 100 to 240
Frequency Range (Nominal) ( Hz ) 50/60
Nominal Input Voltage ( Vrms )
100
120
200
208
220
230
240
Maximum Rated Output Wattage Rating
800
900
1200
1200
1200
1200
1200
Nominal Input Current ( A rms )
9.3
8.6
6.7
6.5
6.1
5.8
5.6
Maximum Rated Input Wattage Rating ( Watts )
889
989
1290
1290
1290
1290
1290
Maximum Rated VA ( Volt-Amp )
927
1031
1345
1345
1345
1345
1345
Efficiency ( % )
90
91
93
93
93
93
93
Power Factor 0.97
Leakage Current ( mA )
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Maximum Inrush Current ( A peak ) 30
Maximum Inrush Current duration ( mS ) 20
Maximum British Thermal Unit Rating ( BTU-Hr )
3033
3375
4403
4403
4403
4403
4403
 
HP 1200W Common Slot Silver Hot Plug Power Supply Kit 500172-B21
Operational Input Voltage Range (Vrms) 100 to 240
Frequency Range (Nominal) (Hz) 50/60
Nominal Input Voltage (Vrms) 100 120 200 208 220 230 240
Maximum Rated Output Wattage 800 900 1200 1200 1200 1200 1200
Nominal Input Current (A rms) 9.7 9.0 7.0 6.8 6.4 6.1 5.9
Max Rated Input Wattage Rating (Watts) 930 1034 1348 1348 1348 1348 1348
Max. Rated VA (Volt-Amp) 970 1079 1406 1406 1406 1406 1406
Efficiency (%) at Max. Rated Output Wattage 86 87 89 89 89 89 89
Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97
Leakage Current (mA) 0.42 0.50 0.83 0.87 0.92 0.96 1.00
Max. Inrush Current (A peak) 30 30 30 30 30 30 30
Max. Inrush Current duration (mS) 20 20 20 20 20 20 20
Maximum British Thermal Unit Rating (BTU-Hr) 3174 3530 4600 4600 4600 4600 4600
To review typical system power ratings use the Active Answers HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor
contents
 Overview      Standard Features      Optional Features      Service and Support      Pre-configured Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Technical Specifications

System Unit
Dimensions (H x W x D)
(with bezel)
3.46 x 17.64 x 28.11 in (8.79 x 44.81 x 71.37 cm)
Weight
(approximate)
Maximum
(all hard drives, power supplies, and processors installed)
69.3 lb (31.43 kg)
Input Requirements
(per power supply)
Rated Line Voltage90 to 140 VAC
180 to 264 VAC
Rated Input Current7.31A at 115VAC
3.6A at 230VAC
Rated Input Frequency47 to 63 Hz
Rated Input Power 855W (at 100 VAC),
840.72W (at 200 VAC)
Power SpecificationsTo review typical system power ratings use the HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient
Power Supply Output
(per power supply)
Rated Steady-State Power 653.10W (at 100 VAC),
653.08W (at 200 VAC)
System Inlet TemperatureOperating50° to 95° F (10° to 35° C) at sea level with an altitude derating of 1.8°F per every 1000 ft (1.0°C per every 305 m) above sea level to a maximum of 10,000 ft (3050 m), no direct sustained sunlight. Maximum rate of change is 18°F/hr (10°C/hr). The upper limit may be limited by the type and number of options installed.
System performance may be reduced if operating with a fan fault or above 86°F (30°C).
Non-operating40° to 140° F (-40° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
Relative Humidity
(non-condensing)
Operating10% to 85% relative humidity (Rh), 82.4°F (28°C) maximum wet bulb temperature, non-condensing.
Non-operating10% to 95% relative humidity (Rh), 101.7°F (38.7°C) maximum wet bulb temperature, non-condensing.
AltitudeOperating10,000 ft (3050 m). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 1500 ft/min (457 m/min).
Non-operating30,000 ft (9144 m). Maximum allowable altitude change rate is 1500 ft/min (457 m/min).
Acoustic NoiseListed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
Idle  
   LWAd6.86
   LpAm52.36dBA
Operating  
   LWAd6.89
   LpAm52.60dBA
Emissions Classification (EMC)FCC RatingClass A
Normative StandardsCISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1
NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements.

Embedded NC362i PCIe Gigabit Server Adapter Network Interface Integrated 10/100/1000BASE-T Transceiver
Combines a triple-speed IEEE 802.3TM - Compliant Media Access Controller (MAC) with a triple-speed Ethernet transceiver.
Data Transfer Method Compliant to x4 PCIe Specification
Controller Intel® 82576
Network Transfer Rate 10Base-T (Half-Duplex) 10 Mb/s
10Base-T (Full-Duplex) 20 Mb/s
100Base-TX (Half-Duplex) 100 Mb/s
100Base-TX (Full-Duplex) 200 Mb/s
1000Base-TX (Half and Full-Duplex) 2000Mb/s
Connector RJ-45 connector
Cable Support Performs all the physical layer functions for 10BASE-T, 100BASE-T, and 1000BASE-T Ethemet on standard Category 5 UTP

Environment-friendly Products and ApproachEnd-of-life Management and Recycling

Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner.

The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment.


© Copyright 2011 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice.

Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries.

The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less.


   DA-13332 21 - Version 21 - November 14, 2011 --- Retired on December 31, 2011