Overview

HP ProLiant SL170z Generation 6 (G6)

Open View:Front View:
1.16 DDR3 DIMM slots
1.Optional low profile x16 PCI-e Gen 2
2.Up to two Intel® Quad-Core 5500 sequence processors2.Serial Port
3.

Six 3.5" non-hot plug hard drives using a quick release drive carrier

3.(2) 1Gbit NIC
4.Optional Dedicated Management port
  5.(2) USB Ports
  6.Power Button
  7.Health LED
  8.UID
  9.Video Port

What's New
  • Support for HP Smart Array P410 and P411
  • Support for 16GB DDR3 DIMM
  • HP SL Universal Switch Rail Kit

At A Glance
The HP ProLiant SL170z is part of a new family, HP ProLiant SL6000, of HP server solutions optimized for scale-out customers to greatly reduce costs, maximize power efficiency, and maintain total flexibility. The SL6000 supports up to two independent HP ProLiant SL170z G6 Servers in the 2U HP ProLiant z6000 G6 Chassis. The servers share power supplies and fans, providing greater power and cooling efficiencies. The HP ProLiant SL170z G6 Server is a two socket Intel server with 16 DDR3 DIMM sockets.
  • Processors:
    • Up to two Quad-Core Intel® processor 5500 sequence
    • Intel® 5520 Chipset
  • Memory:
    • Up to 128 GB, using PC3-8500R DDR3 Registered (RDIMM) memory, operating at 800MHz when fully populated in 16 slots
    • Up to 24 GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fully populated at 2 DIMMs per Channel in 12 slots
  • Internal Drive Support:
    • Support for up to six 3.5" non-hot plug Serial ATA (SATA) or Serial Attached SCSI (SAS) hard drives using a quick release drive carrier
    • Support for up to eight 2.5" non-hot plug Serial ATA (SATA), Serial Attached SCSI (SAS), or Solid State Drive (SSD) hard drives using a quick release drive carrier and the SFF drive cage
  • Network Controller:
    • HP NC362i Integrated Dual Port Gigabit Server Adapter
  • Storage Controllers:
    • HP Embedded SATA RAID Controller (RAID 0, 1, 10) per server node
      NOTE: Transfer rate: 3.0 Gb/s SATA
  • Expansion Slots:
    • One available PCI Express Gen 2.0 slots
    • Slot 1: Low profile x16 PCI-Express 2.0
  • Management:
    • HP ProLiant Onboard Administrator Powered by Lights-Out 100 with optional LO100i Advanced Licenses for Virtual KVM and Virtual Media
    • The HP ProLiant Easy Set-up CDs and ISO image downloads offer Assisted and Manual single server installation, setup, and deployment capability. Capabilities provided are:
      • AutoRun
      • Assisted Installation Microsoft Windows 2003 Server and Microsoft Windows 2008 Server
      • OS and SW available for Manual Installation are listed on each servers' QuickSpecs
    • HP Insight Diagnostics
    • Smart Components - a self-executable software consisting of driver and firmware
    • HP Smart Update Manager - a single system and multi-server deployment tool for Windows environments that works with Smart Components to provide customers with easy-to-use GUI and Script-based deployment capacity
    • SmartStart Scripting Toolkit - an automated scalable deployment utility
    • Insight Management Agents for environmental monitoring that is similar to and consistent with that of HP ProLiant 300 series and above servers and that allows integration to HP Systems Insight Manager (SIM)
    • Array Configuration Utility (ACU)
    • Array Diagnostics Utility (ADU)
    • HP Insight Control for Linux (IC-Linux), a product option, delivers essential lifecycle management that can help save time and money by integrating discovery, server deployment, firmware updates & provisioning, health & performance management, remote management, and virtualization. This makes it easy to optimize your IT infrastructure through a single, simple management console. The Insight Control for Linux suite supports Linux-based servers and management consoles.
  • Operating Systems and Virtualization Software Support for ProLiant Servers:
    • Supports Windows, RHEL, SLES, Solaris
  • USB Ports:
    • Three USB ports / server node (two front, one internal)
  • Optical Drive:
    • External support only
  • Power Supply:
    • The 2U chassis supports three power supply options:
      • Common Slot Power Supplies enable power capping and hot-pluggability
        • HP 1200W CS HE Silver Power Supply (Hot Plug, Autoswitching) (optional)
        • HP 750W CS HE Gold Power Supply (Hot Plug, Autoswitching) (optional)
        • HP 460W CS HE Gold Power Supply (Hot Plug, Autoswitching) (optional)
  • Form Factor:
    • HP ProLiant z6000 G6 Chassis - 2U
    • HP ProLiant SL170z Server - 1U Server Tray
  • Warranty:
    • This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners. Hardware diagnostic support and repair is available for one year from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. Hard drives have either a one year or three year warranty.
      NOTE: Server Warranty includes 1 year Parts, 1 year Labor, 1-year on-site support with next business day response. Warranty repairs may be accomplished through the use of Customer Self Repair (CSR) parts. These parts fall into two categories: 1) Mandatory CSR parts are designed for easy replacement. A travel and labor charge will result when customers decline to replace a Mandatory CSR part; 2) Optional CSR parts are also designed for easy replacement but may involve added complexity. Customers may choose to have HP replace Optional CSR parts at no charge. Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html.
contents
 Overview      Standard Features      HPC Interconnects      Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Standard Features

NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - Factory Integrated Models" section.

Processor
One of the following depending on Model
Quad-Core Processor
Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3)
Intel® Xeon® Processor X5560 (2.8 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo, 2/2/3/3)
Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo, 2/2/3/3)
Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor L5530 (2.40 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800)
Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)
Dual-Core Processors
Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800)
NOTE: HT indicates that the processor model supports Intel® Hyper-Threading Technology
NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream), and "L" denotes Lower Wattage.
NOTE: Up to 2 processors supported. Mixing different processor models is not supported.

Upgradeability Upgradeable to two processors

ChipsetIntel® 5520 Chipset
NOTE: For more information regarding Intel chipsets, please see the following URL:
http://www.intel.com/products/server/chipsets/

Cache Memory
One of the following depending on Model
8 MB (1 x 8MB) Level 3 cache
NOTE: All processor models except for those identified below.
4 MB (1 x 4MB) Level 3 cache
NOTE: For processors L5506, E5504 and E5502.

Memory ProtectionAdvanced memory protection

MemoryTypeDDR3 Registered (RDIMM) or Unbuffered (UDIMM)
Standard (per server tray)
6 GB (3 x 2 GB) UDIMMs
Maximum (RDIMM) (per server tray)
128 GB (16 x 8 GB) for Registered Memory configurations
Maximum (UDIMM) (per server tray)24 GB (12 x 2 GB) for Unbuffered Memory configurations
NOTE: Depending on the memory configuration and processor model, the memory speed may run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration Tool at: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient.
DDR3 memory options part number decoder

Network ControllerHP NC362i Integrated Dual Port Gigabit Server Adapter

Expansion Slots
Expansion Slots #
Technology
Bus Width**
Connector Width
Form Factor
Notes
1
PCI-Express 2.0
x16
x16
Low Profile
3.3 volts
** Indicates the number of physical electrical lanes running to the connector.

Storage ControllerHP Embedded SATA RAID Controller (RAID 0, 1, 10) per server node
NOTE: Transfer rate: 3.0 Gb/s SATA.
NOTE: A HP Smart Array controller is required for SAS Hard Drives
NOTE: An external diskette drive, USB floppy drive key or virtual FDD using LO100 Advanced Pack is needed to install storage controller drivers during a Windows operating system installation from a CD.
NOTE: A HP Smart Array Controller is required for SAS HDD.

Storage Optical Drives DVD / CD drives via USB only
Diskette Drives
Via USB only
Drive Bays None ship standard
Up to 6 Non-hot plug SATA or SAS 3.5" drives
Up to 8 Non-hot plug SATA, SAS, or SSD 2.5" drives (requires SFF drive cage)

Maximum Internal Storage Non-Hot Plug SATA 3.5" 6.0TB 6 x 1TB
Non-Hot Plug SAS 3.5" 1.8TB 6 x 300GB
Non-Hot Plug SATA 2.5" 4TB 8 x 500GB
Non-Hot Plug SAS 2.5" 2.4TB 8 x 300GB
Non-Hot Plug SSD 2.5" 960GB 8 x 120GB

InterfacesParallelNone
Network RJ-452 10/100/1000 NIC ports (1 NIC shared for the HP ProLiant Lights Out 100i Remote Management)
Serial1
Graphics1
USB

3 (two front, one internal)
NOTE: Please see the following URL for additional information regarding USB support:
http://h18004.www1.hp.com/products/servers/platforms/usb-support.html

Management1 Optional Dedicated LO100i Management Port
Health LED
1 front per server node
Power
1 front per server node
UID1 front per server node

Graphics

32MB shared supporting 1600x1200x16M resolution


Form FactorHP ProLiant z6000 G6 Chassis - 2U Chassis can support up to two SL170z server trays in the 2U chassis
HP ProLiant SL170z G6 Server - 1U server tray

Embedded Manageability

HP ProLiant Onboard Administrator Powered by LO100 with LO100i Advanced

HP ProLiant Onboard Administrator Powered by Lights-Out 100 is standard with this server and has LO100i Advanced Licenses for Virtual KVM and Virtual Media available as options.

Standard Features:

  • Embedded IPMI standard reporting
  • System event log access
  • Remote Serial console (serial redirection)
  • Browser, Telnet access
  • SMASH-CLP compliant
  • IPMI 2.0 compliant
  • DCMI 1.0 Compliant
  • Secure Socket Layer Encryption
  • Secure Shell Encryption

Licensed Features:

  • Virtual media (Floppy, CD, USB 2.0) with Advanced License
  • Virtual KVM with Advanced License

HP Insight Control management software HP Insight Control for Linux

HP Insight Control for Linux (IC-Linux), as a product option, delivers essential lifecycle management that can help save time and money by integrating discovery, server deployment, firmware updates & provisioning, health & performance management, remote management, and virtualization. This makes it easy to optimize your IT infrastructure through a single, simple management console. The IC-Linux suite installs and licenses software modules that are integrated into HP System Insight Manager (HP SIM).

HP Insight Control for Linux serves environments requiring a Linux-based management console. See www.hp.com/go/ic-linux.

HP Insight Control for Linux includes one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/insight


Core Infrastructure Management

HP Insight Rapid Deployment software

HP Insight Rapid Deployment software (RDP) extends HP Systems Insight Manager with a complete deployment solution for HP ProLiant servers. RDP provides a central location (running on a Windows CMS) to configure server hardware, deploy Windows, Linux and VMware ESX operating environments and install HP ProLiant Support Pack drivers using images and scripted profiles. For more information, visit: http://www.hp.com/go/rdp.

HP Systems Insight Manager HP Systems Insight Manager (HP SIM) provides a unified, secure and extensible standards-based environment to centrally manage servers, storage and other infrastructure devices, (both HP and non-HP) across multiple operating system platforms.

For additional information, please see: http://www.hp.com/go/insight.
Subscriber's Choice Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides software and driver change notifications for ProLiant products. Sign up at: http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis.
ROMPaq, software and latest drivers

The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options; downloaded from Software and Drivers download pages website at: http://www.hp.com/go/support and from www.hp.com/servers/easysetup. Contains the following:

  • HP Insight Management Agents for Systems Insight Manager (SIM) Integration
  • HP Systems Management Homepage
  • Array Configuration Utility (ACU)
  • Array Diagnostics Utility (ADU)
  • HP Insight Diagnostics

Industry Standard ComplianceACPI V2.0 Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Microsoft® Logo certifications
IPMI 2.0
DCMI 1.0
SMASH CLP compliant

SecurityPower-on password
Setup password
Diskette boot control
Secure Sockets Layer (SSL)
Secure Shell (SSH)

Security - Trusted Platform Module

Trusted Platform Module option kit

The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to authenticate the server platform. These artifacts can include passwords, certificates and encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user data and to ensure that a server running Windows Server 2008 has not been tampered with while the system was offline.

NOTE: For more information about TPM, including a white paper, go to http://www.hp.com/go/TPM
NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment.
NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or loosing the key could result in data loss.


Server Power Cords

One 6' Highline (IEC-IEC) power cord ships standard
NOTE: HP ProLiant SL servers are primarily connected to PDU's in data center racks so they ship standard with only a PDU power cord (416151-B21). If a user wishes to power a ProLiant SL server using a 110V receptacle (NEMA-15), the NEMA power cord (227099-001) must be ordered separately.

NOTE: If customers require a power cord, they can check the power cord matrix for the appropriate cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix.


UPS and PDU Power
Cord Matrix
Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords.

Power SupplyHP has a new design for ProLiant power. The new Common Slot Power Supply bay. This design provides the customer with commonality in power supplies across multiple platforms to save on the cost of spares and allows HP to offer multiple power solutions to fit the customers' needs. Many HP ProLiant Servers come with Common Slot, High Efficiency and Right-Size Power Supplies. Common Slot (CS) designates commonality of the power supply across multiple ProLiant servers. HP's new Common Slot power supplies are designed for highest efficiency to provide power efficiency without degrading performance of the ProLiant. Power Supplies will have efficiency ratings up to 92%. There are three Right Size power options available, depending on the configuration of your server. To make sure you select the correct power supply to meet your configuration, we suggest that you use the HP Power Calculator to decide the "Right-Size" for your configuration. All HP Common Slot power sources are UL, CE Mark Compliant, Hot Plug and Redundant (redundancy dependent on node configurations).

Common Slot ProLiant

It is highly recommended that you use the HP Power Calculator in defining the "Right-Size" power supply for your needs. HP offers three Power Supply Options:

  • HP 460Watts, Common Slot,92% Efficiency
  • HP 750Watts, Common Slot, 92% Efficiency
  • HP 1200Watts, Common Slot, 90% Efficiency

The HP ProLiant Common Slot Power supplies meet multiple Energy Efficiency Initiatives: Climate Savers Computing Initiative GOLD and ECOS Consulting 80PLUS GOLD for the 460w and 750w Power Supplies and Climate Savers Computing Initiative Silver, ECOS Consulting 80PLUS Silver for 1200w Power Supply. HP has also been working with the EPA on developing an ENERGY STAR? Computer Server specification and plans on offering models that meet the requirements when they are published. Please visit the ENERGY STAR website at: www.energystar.gov for updates on the specification development process and approved platforms.

Optional power supplies can be purchased through power supply option kits (see Power Supply Options for part numbers).


System Fans3 system fans ship standard in z6000 chassis

Operating Systems and Virtualization Software Support for ProLiant Servers

Microsoft Windows Server
Microsoft Windows Server Hyper V
Microsoft HPC Server 2008
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
Solaris
VMware ESX
Citrix Essentials for XenServer

NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/ossupport and our driver download page www.hp.com/support/sl170zG6.

Rack Airflow Requirements Rack 10000 G2 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.

CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:

Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 5,350 sq cm (830 square inches) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 7 cm (2.75 inches)

CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.
NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: www.hp.com/servers/SL170z.

Rack Support

HP ProLiant SL170z G6 models have two different rail kits to choose from:

  • 10U bulk rail kit - Used to fit in HP 10000 series racks
    • One 10U bulk rail kit will hold up to five z6000 chassis, thus ten SL170z G6 server trays
  • 2U rail kit - Used to fit in 3rd party racks or to sell one z6000 chassis at a time
    • One 2U rail kit will hold one z6000 chassis, thus two SL170z servers

For additional information, please visit: www.hp.com/go/rackandpower.


Factory Express Portfolio for Servers and Storage HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed.

Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches.

For more information on Factory Express services for your specific server model please contact your sales representative or go to: http://www.hp.com/go/factory-express.

HP Enterprise Configurator

The HP eConfigure Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. http://www.hp.com/products/configurator


Service and Support

HP Care Pack Services provide total care and support expertise with committed response designed to meet your IT and business needs.

HP Care Pack Services provide total care and support expertise with committed response designed to meet your IT and business needs.

HP Care Pack services include coverage for the HP branded hardware options qualified for the server that are purchased at the same time or afterward and internal to the enclosure. It also includes the 22" and smaller external monitors and tower UPS options up to 3kVA. These items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included and standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack.

To fully capitalize on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime.

Recommended Service – Simplify ProLiant solution implementation, maintenance and management.

  • Support Service – 3 Year, 9x5 Next Business Day coverage, excluding HP holidays only
  • Deployment Service – Hardware Installation only

Enhanced Service – Optimize service level to increase IT performance and availability

  • Support Service – 3 Year 13x5 Same Business Day, 4-Hour response coverage
  • Deployment Service – Installation and Start-up only

Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays.

For a complete listing of service offerings and information visit:
http://www.hp.com/services/proliantservices
http://www.hp.com/services/carepack

contents
 Overview      Standard Features      HPC Interconnects      Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

HPC Interconnects

NOTE: High Performance Computing (HPC) interconnect technologies are available for the SL170z G6 under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects: http://www.hp.com/techservers/clusters/ucp/index.html

HPC Interconnects InfiniBand PCI-Express adapters
Gigabit Ethernet Use embedded ports
contents
 Overview      Standard Features      HPC Interconnects      Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Models

Non-Hot Plug Serial ATA (SATA) Model
NOTE: Non-Hot Plug models are not upgradeable to Hot Plug.
NOTE: A rail kit is not included in model - this allows for the purchase of the right size rail kit.
NOTE: This Model includes two HP ProLiant SL170z Server trays. Specs below represent configuration of each tray.
HP ProLiant SL170z G6, 2 trays, E5504, 6GB
539611-001
Processor(s) (1) Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)
Cache Memory 4MB shared L3 cache
Memory 6GB (3 x 2GB) PC3-10600E (UDIMM)
Network Controller HP NC362i Integrated Dual Port Gigabit Server Adapter
Storage Controller Embedded SATA RAID 0, 1, 10
Hard Drive Optional SATA
Internal Storage Up to 6 large form factor Non-Hot Plug drives/Server tray using Quick Release carrier
Power Supply 750W
Fans 3 system fans ship standard in z6000 chassis
Form Factor One HP ProLiant z6000 G6 Chassis
Two HP ProLiant SL170z G6 Server
contents
 Overview      Standard Features      HPC Interconnects      Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Configuration Information - Factory Integrated Models

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for additional information.
NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis.
NOTE: FIO indicates that this option is a Factory Installable Option.

Step 1: Base Configuration (choose one from each list unless otherwise noted)
Chassis HP ProLiant z6000 G6 Chassis 538080-B21
NOTE: Ships with 2U chassis and 3 fans

Server Node

HP ProLiant SL170z G6 Server
NOTE: It is required that 2 server trays be purchased.
NOTE: Each SL170z tray has 1 system board.
570147-B21

Rail Kits

HP ProLiant z6000 G6 2U rail kit
NOTE: 2U rail kit used for HP or 3rd part racks - allows addition of one z6000 chassis at a time.
570226-B21
HP ProLiant z6000 G6 10U Bulk rail kit
NOTE: 10U rail kit used for HP racks ONLY - allows addition of five z6000 chassis at a time.
570227-B21

Power Supplies

NOTE: Refer to HP Power Advisor when selecting a power supply for your configuration, www.hp.com/go/hppoweradvisor. Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at "www.hp.com/go/proliant-energy-efficient" or www.hp.com/go/hppoweradvisor
HP 460W CS HE Gold Power Supply 503296-B21
HP 750W CS HE Gold Power Supply 512327-B21
HP 1200W CS HE Silver Power Supply 500172-B21

Step 2: Choose Required Server Node Options (only one of the following from each list unless otherwise noted)
Processors Quad-Core Processors
Intel® Xeon® processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO Base
NOTE: If 2 processors are desired, select one 539252-L21 and one 539252-B21.
539252-L21
Intel® Xeon® processor X5560 (2.8 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO Base
NOTE: If 2 processors are desired, select one 588191-L21 and one 588191-B21.
588191-L21
Intel® Xeon® processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO Base
NOTE: If 2 processors are desired, select one 539254-L21 and one 539254-B21.

539254-L21

Intel® Xeon® processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO Base
NOTE: If 2 processors are desired, select one 539256-L21 and one 539256-B21.
539256-L21
Intel® Xeon® processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO Base
NOTE: If 2 processors are desired, select one 539260-L21 and one 539260-B21.
539260-L21
Intel® Xeon® processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO Base
NOTE: If 2 processors are desired, select one 539266-L21 and one 539266-B21.
539266-L21
Intel® Xeon® processor L5530 (2.4 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2), FIO Base
NOTE: If 2 processors are desired, select one 586601-L21 and one 586601-B21.
586601-L21
Intel® Xeon® processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2), FIO Base
NOTE: If 2 processors are desired, select one 571698-L21 and one 571698-B21.
571698-L21
Intel® Xeon® processor L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800), FIO Base
NOTE: If 2 processors are desired, select one 571703-L21 and one 571703-B21.
571703-L21
Dual-Core Processors  
Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO
NOTE: If 2 processors are desired, select one 571705-L21 and one 571705-B21.
571705-L21
NOTE: HT indicates that the processor model supports Intel® Hyper-Threading Technology.
NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage.
 

Memory Registered DIMMs (RDIMMs)  
HP 2GB 2Rx8 PC3-10600R-9 Kit
500656-B21
HP 4GB 2Rx4 PC3-10600R-9 Kit
500658-B21
HP 4GB 4Rx8 PC3-8500R-7 LP Kit
500660-B21
HP 8GB 2Rx4 PC3-10600R-9 Kit
500662-B21
HP 8GB 2Rx4 PC3-8500R-7 Kit
516423-B21
HP 16GB 4Rx4 PC3-8500R-7 Kit 500666-B21
Unbuffered with ECC DIMMs (UDIMMs)
NOTE: Maximum 12 DIMMs supported per node
HP 1GB 1Rx8 PC3-10600E-9 Kit 500668-B21
HP 2GB 2Rx8 PC3-10600E-9 Kit 500670-B21
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient
NOTE: There is a maximum support limitation of 8 ranks per memory channel (maximum of 2 quad rank DIMMs per channel)

Hard Drive NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Hard drives have either a one year or three year warranty.
NOTE: The hard drives use a quick release carrier.
NOTE: One 2 Drive SFF Drive Cage (582657-B21) is required when installing 2 SFF (2.5in) drives
NOTE: When Adding SAS Drives one of the following cable kits needs to be ordered depending on which SAS controller installing - HP P212 SAS 4HDD Cable Kit 574001-B21.
 
SAS Enterprise (ENT) Drives - with quick-release (QR) carrier  
HP 600GB 6G SAS 15K 3.5in QR DP ENT HDD 574758-B21
HP 300GB 6G SAS 15K 3.5in QR DP ENT HDD 585980-B21
HP 300GB 6G SAS 10K 2.5in QR DP ENT HDD 574879-B21
SATA Entry (ETY) Drives - with quick-release (QR) carrier  
HP 160GB 3G SATA 7.2K 3.5in QR ETY HDD 574021-B21
SATA Midline (MDL) Drives - with quick-release (QR) carrier  
HP 500GB 3G SATA 7.2K 3.5in QR MDL HDD 574023-B21
HP 1TB 3G SATA 7.2K 3.5in QR MDL HDD 574025-B21
HP 500GB 3G SATA 7.2K 2.5in QR MDL HDD 574953-B21
HP 160GB 3G SATA 7.2K 2.5in QR MDL HDD 574893-B21
NOTE: The HP SATA / PW CBL SL160/170 G6 KIT (574005-B21) is needed when adding more than six 2.5" hard drives.  
SATA Midline (MDL) Solid State Drives - with quick-release (QR) carrier  
HP 120GB 3G SATA 2.5in QR MDL SSD 586587-B21
HP 60GB 3G SATA 2.5in QR MDL SSD 586585-B21

Storage Controllers HP P212/256 FIO SA Cntrlr w/Battery
NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller (574001-B21)
NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21)
491191-B21
HP Smart Array P410/ZM FIO Controller
NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller (583997-B21)
462860-B21
HP Smart Array P410/256 MB w/ Battery FIO
NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller (583997-B21)
NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21)
491195-B21
HP Smart Array P411/256 MB w/ Battery FIO
NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21)
491193-B21

Step 3: Choose Additional Factory Integratable Options
NOTE: For additional options, please refer to the "Core Options" and "Additional Options" section below.
contents
 Overview      Standard Features      HPC Interconnects      Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Core Options

NOTE: Some options may not be factory integrated. Please contact your local sales representative for additional information.
Unique Options HP Dedicated MGT Port Kit 517405-B21
HP I/O Riser x16 SL160/170 G6 KIT
574806-B21
HP ProLiant z6000 Redundant Fan Kit 538082-B21

HP ProLiant z6000 Tray blank kit
NOTE: This is needed to help with cooling if a tray is removed from the z6000.

574551-B21

HP ProLiant z6000 Cable Management Kit
NOTE: This is needed when using Fiber cables.
575156-B21
1U Filler Panel Blank Mounting Bracket
NOTE: This is needed to mount the 1U blanking panel back with server when the server is recessed mounted.
579069-B21
HP P212 SAS 4HDD Cable Kit
NOTE: This is required when adding SAS hard drives using the P212 controller.
574001-B21
HP P410 SAS 4HDD Cable Kit
NOTE: This is required when adding SAS hard drives using the P410 controller.
583997-B21
HP SATA / PW CBL SL160/170 G6 KIT
NOTE: This is needed when adding more than six 2.5" hard drives.
574005-B21
HP z6000 BBWC HDWR KIT
NOTE: This is required when adding BBWC.
582653-B21
2 Drive SFF Drive Cage
NOTE: This is required when adding SFF (2.5") SSD or hard drives.
582657-B21
HP z6000 Processor / Memory Blank Kit
NOTE: This is optional to give the best cooling efficiency when server trays are not configured exactly the same in the z6000 chassis.
579255-B21

Processor Quad-Core Processors  
Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) 539252-B21
Intel® Xeon® Processor X5560 (2.8 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) 588191-B21
Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3)

539254-B21

Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)

539256-B21

Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)

539260-B21

Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)

539266-B21

Intel® Xeon® Processor L5530 (2.4 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) 586601-B21
Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2)

571698-B21

Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800)
571703-B21
Dual-Core Processors  
Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800)
571705-B21
NOTE: HT indicates that the processor model supports Intel® Hyper-Threading Technology.
NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage.
 

Memory

Registered DIMMs (RDIMMs)  
HP 2GB 2Rx8 PC3-10600R-9 Kit
500656-B21
HP 4GB 2Rx4 PC3-10600R-9 Kit
500658-B21
HP 4GB 4Rx8 PC3-8500R-7 LP Kit 500660-B21
HP 8GB 2Rx4 PC3-10600R-9 Kit 500662-B21
HP 8GB 2Rx4 PC3-8500R-7 Kit 516423-B21
HP 16GB 4Rx4 PC3-8500R-7 Kit 500666-B21
Unbuffered with ECC DIMMs (UDIMMs)
NOTE: Maximum 12 DIMMs supported per node
 
HP 1GB 1Rx8 PC3-10600E-9 Kit 500668-B21
HP 2GB 2Rx8 PC3-10600E-9 Kit 500670-B21
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient
 
NOTE: There is a maximum support limitation of 8 ranks per memory channel (maximum of 2 quad rank DIMMs per channel)

Hard Drives NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Hard drives have either a one year or three year warranty.
NOTE: The hard drives use a quick release carrier.
NOTE: One 2 Drive SFF Drive Cage (582657-B21) is required when installing 2 SFF (2.5in) drives.
NOTE: When adding SAS one of the following cable kits needs to be ordered depending on which SAS controller installing - HP P212 SAS 4HDD Cable Kit 574001-B21.
 
SAS Enterprise (ENT) Drives - with quick-release (QR) carrier  
HP 600GB 6G SAS 15K 3.5in QR DP ENT HDD 574758-B21
HP 300GB 6G SAS 15K 3.5in QR DP ENT HDD 585980-B21
HP 300GB 6G SAS 10K 2.5in QR DP ENT HDD 574879-B21
SATA Entry (ETY) Drives - with quick-release (QR) carrier  
HP 160GB 3G SATA 7.2K 3.5in QR ETY HDD 574021-B21
SATA Midline (MDL) Drives - with quick-release (QR) carrier  
HP 500GB 3G SATA 7.2K 3.5in QR MDL HDD 574023-B21
HP 1TB 3G SATA 7.2K 3.5in QR MDL HDD 574025-B21
HP 500GB 3G SATA 7.2K 2.5in QR MDL HDD 574953-B21
HP 160GB 3G SATA 7.2K 2.5in QR MDL HDD 574893-B21
SATA Midline (MDL) Solid State Drives - with quick-release (QR) carrier  
HP 120GB 3G SATA 2.5in QR MDL SSD 586587-B21
HP 60GB 3G SATA 2.5in QR MDL SSD 586585-B21

Communications Gigabit Ethernet Adapters  
HP NC112T PCIe Gigabit Server Adapter 503746-B21
HP NC360T PCI Express Dual Port Gigabit Server Adapter 412648-B21
HP NC364T PCI Express Quad Port Gigabit Server Adapter 435508-B21
HP NC373F PCI Express Multifunction Gigabit Server Adapter 394793-B21
HP NC373T PCI Express Multifunction Gigabit Server Adapter 394791-B21
HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter 458492-B21
HP NC375T PCI Express Quad Port Gigabit Server Adapter 538696-B21
10 Gigabit Ethernet Adapters  
HP NC522SFP Dual Port 10GbE Server Adapter
NOTE: A minimum of two Gigabytes (2 GB) of server memory is required per each NC522SFP adapter.
NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately.
468332-B21
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs.  

Riser Cage OptionsHP I/O Riser x16 SL160/170 G6 KIT
574806-B21

Redundant Options CAUTION: In ProLiant Servers that have more than one power slot (bay), only same size power supplies are recommended. If non-matched power supplies are inserted you will get errors and operation will fail.
HP 460W CS HE Gold Power Supply 503296-B21
HP 750W CS HE Gold Power Supply 512327-B21
HP 1200W CS HE Silver Power Supply 500172-B21
NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. 
contents
 Overview      Standard Features      HPC Interconnects      Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Additional Options

Remote Management HP LO100i Advanced Pack, No Media 1-Server License including 1 year of 24x7 Technical Support and Updates
530521-B21
NOTE: For additional information, please see the Lights-Out 100i QuickSpecs at www.hp.com/go/lo100.

HP Insight Control HP Insight Control for Linux  
HP Insight Control for Linux, 1-server license, including one year of 24x7 Technical Support and Updates, Electronic
T9084BAE
HP Insight Control for Linux, No Media, 1-Server license, including one year of 24x7 Technical Support and Updates 464423-B22
HP Insight Control for Linux, Media pack (DVD) - No licenses included
NOTE: Media pack DVD contains the ISO image for HP Insight Control for Linux, HP Systems Insight Manager, HP Insight Control power management, HP Insight Control virtual machine management, and an integrated installer. Servers must be acquired separately.
464422-B22
NOTE: Licenses ship without media. The Media Kit for Insight Control for Linux can be ordered separately, or can be downloaded at: http://www.hp.com/go/ic-linux (click on Download button).
NOTE: Electronic and Flexible-Quantity licenses can be used to purchase multiple licenses with a single set of activation keys.
NOTE: For additional License Kits, including electronic licensing options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_na/13019_na.html
 

Rail Options HP ProLiant z6000 G6 2U rail kit
NOTE: 2U rail kit used for HP or 3rd part racks - allows addition of one z6000 chassis at a time.
570226-B21
HP ProLiant z6000 G6 10U Bulk rail kit
NOTE: 10U rail kit used for HP racks ONLY - allows addition of five z6000 chassis at a time.
570227-B21
HP SL Universal Switch Rail Kit
NOTE: This kit allows you to install HP or 3rd party switch in the same rack as SL6000.
592774-B21
HP ProCurve 6600 rail kit
NOTE: This rail kit is used to mount the ProCurve 6600 switch recessed with the z6000 chassis.
538062-B21
CISCO 4948 rail kit
NOTE: This rail kit is used to mount the CISCO 4948 switch recessed with the z6000 chassis.
574549-B21

SecurityHP Trusted Platform Module Option Kit
488069-B21

Storage Controllers SAS Controllers
Smart Array P212 Controller
NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller (574001-B21).
 
HP Smart Array P212/Zero Memory Controller 462828-B21
HP Smart Array P212/256 MB Controller 462834-B21
Smart Array P410 Controller
NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller (583997-B21)
 
HP Smart Array P410/256MB Controller 462862-B21
HP Smart Array P410/512MB with BBWC 462864-B21
Smart Array P411 Controller  
HP Smart Array P411/256MB Controller 462830-B21
HP Smart Array P411/512MB Battery Backed Write Cache 462832-B21
Optional Upgrades
NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21).
 
256 MB Cache Module
NOTE: Supported on HP Smart Array P212 Controller only.
462968-B21
512MB BBWC
NOTE: Supported on HP Smart Array P410 Controller and HP Smart Array P411 Controller only.
462967-B21
Battery Kit upgrade
NOTE: To enable BBWC on the 256MB cache.
NOTE: Supported on HP Smart Array P212 Controller.
462969-B21
NOTE: Please see the following QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13203_na/13203_na.html
(Smart Array P212 Controller)
http://h18000.www1.hp.com/products/quickspecs/13201_na/13201_na.html
(Smart Array P410 Controller)
http://h18000.www1.hp.com/products/quickspecs/13202_na/13202_na.html
(Smart Array P411 Controller)
 
SCSI HBA  
HP SC11Xe Host Bus Adapter
NOTE: Recommended HBA for SCSI tape drive connect.
412911-B21
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12566_na/12566_na.html
(SCSI HBA)
 

HPC Specific Options HP IB 4X DDR PCI-e Dual Port 0 Memory HCA 483513-B21
HP IB 4X DDR Conn-X PCI-e G2 Dual Port HCA 483514-B21
HP IB 4X DDR PCI-e Dual Port HCA 409376-B21
HP IB 4X DDR PCI-e DUAL PORT HCA 448397-B21
HP IB 4X QDR CX-2 PCI-e G2 Dual Port HCA 592520-B21
HP IB 4X DDR CX-2 PCI-e G2 Dual Port HCA 592521-B21
NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13078_na/13078_na.html  

StorageWorks Options StorageWorks SCSI HBA  
HP U320e SCSI Host Bus Adapter
NOTE: Recommended HBA for MSL SCSI Tape Library connect.
AH627A

HP StorageWorks Modular Smart Array MSA SAN Storage Arrays  
HP StorageWorks 50 Modular Smart Array 364430-B21
NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12245_na/12245_na.html  
HP StorageWorks 60 Modular Smart Array 418408-B21
NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12627_na/12627_na.html  
HP StorageWorks 70 Modular Smart Array 418800-B21
NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12652_na/12652_na.html  

Uninterruptible Power Systems HP Rack-mountable UPS
HP UPS R1500 G2 UPS  
HP, R1.5k VA UPS, 1U
AF419A
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12507_na/12507_na.html

HP Rack Series HP Rack 5000 Series (Graphite Metallic)  
HP 5642 Rack-Unassembled 358254-B21
NOTE: Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.html
 
HP Rack 10000 G2 Series (Carbon/Graphite Metallic)  
S10614 (14U) Rack Cabinet - Shock Pallet 292302-B22
10642 G2 (42U) Rack Cabinet - Pallet AF001A
10642 G2 (42U) Rack Cabinet - Shock Pallet AF002A
10642 G2 (42U) Rack Cabinet - Crated AF003A
10636 G2 (36U) Rack Cabinet - Pallet AF011A
10636 G2 (36U) Rack Cabinet - Shock Pallet AF012A
10636 G2 (36U) Rack Cabinet - Crated AF013A
10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet AF014A
10622 G2 (22U) Rack Cabinet - Pallet AF021A
10622 G2 (22U) Rack Cabinet - Shock Pallet AF022A
10642 G2 (42U) Rack Cabinet 1200mm Deep - Shock Pallet AF034A
10642 G2 (42U) Rack Cabinet 1200mm Deep - Pallet AF038A
10842 G2 (42U) 800mm Wide Rack Cabinet - Pallet AF041A
10842 G2 (42U) 800mm Wide Rack Cabinet - Shock Pallet AF042A
10647 G2 (47U) Rack Cabinet - Pallet AF031A
10647 G2 (47U) Rack Cabinet 1200mm Deep - Shock Pallet
NOTE: Due to handling and shipping requirements, AF044A is only orderable through HP Factory Express. It is not for direct sales. Customer site surveys are required before an order is approved. CTO orders may require additional lead time.
AF044A
10647 G2 (47U) Rack Cabinet 1200mm Deep - Pallet AF045A
NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed.
NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels).
 
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html
 
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower.  

HP Rack Options Keyboards and Monitors  
TFT7600 Rackmount Keyboard Monitor AG052A
1U Rackmount Keyboard with USB AG072A
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower.  
HP KVM Switch Options  
2x1x16 IP Console Switch with Virtual Media AF601A
4x1x16 IP Console Switch with Virtual Media AF602A
2x16 Server Console Switch with Virtual Media AF600A
PS/2 Virtual Media Interface Adapter, 1 pack
NOTE: Requires PS/2 and one USB port on server.
AF604A
Server console switch 0x2x8 AF616A
Server console switch 0x2x16 AF617A
PS/2 Interface Adapter, 1 pack 262588-B21
PS/2 Interface Adapter, 8 pack 262587-B21
NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm.  
HP 1x4 Console Switch  
HP PS2 Server Console Cable, 6 foot, 2-Pack AF611A
HP USB Server Console Cable, 6 foot, 2-Pack
NOTE: Required for supporting USB peripherals.
AF612A
NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm.  
HP Serial Console Server Options AF613A
HP 16 Port Serial Console Server AF101A
HP 48 Port Serial Console Server AF102A
Serial Adapter, RJ45-DB9 DCE Female, 1 Pack AF103A
Serial Adapter, RJ45-DB9 DCE Female, 8 Pack AF110A
NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm.
NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm.
 

Service and Support Offerings
(HP Care Pack Services)
HP 1y 4h 13x5 SL6000 HW Support
UR258E
HP 1y 4h 24x7 SL6000 HW Support
UR259E
HP 1y 6h 24x7 CTR SL6000 HW Supp
UR260E
HP 3y Nbd SL6000 HW Support
UR261E
HP 3y Nbd w/DMR SL6000 HW Supp
UR262E
HP 3y 4h 13x5 SL6000 HW Support
UR263E
HP 3y 4h13x5 w/DMR SL6000 HWSupp
UR264E
HP 3y 4h 24x7 SL6000 HW Support
UR265E
HP 3y 4h24x7 w/DMR SL6000 HWSupp
UR266E
HP 3y 6h 24x7 CTR SL6000 HW Supp
UR267E
HP 3y 6h24x7 CTRw/DMR SL6000 HWSup
UR268E
HP 4y Nbd SL6000 HW Support
UR269E
HP 4y Nbd w/DMR SL6000 HW Supp
UR270E
HP 4y 4h 13x5 SL6000 HW Support
UR271E
HP 4y 4h13x5 w/DMR SL6000 HWSupp
UR272E
HP 4y 4h 24x7 SL6000 HW Support
UR273E
HP 4y 4h24x7 w/DMR SL6000 HWSupp
UR274E
HP 4y 6h 24x7 CTR SL6000 HW Supp
UR275E
HP 4y 6h24x7 CTRw/DMR SL6000 HW Supp
UR276E
HP 5y Nbd SL6000 HW Support
UR277E
HP 5y Nbd w/DMR SL6000 HW Supp
UR278E
HP 5y 4h 13x5 SL6000 HW Support
UR279E
HP 5y 4h13x5 w/DMR SL6000 HWSupp
UR280E
HP 5y 4h 24x7 SL6000 HW Support
UR281E
HP 5y 4h24x7 w/DMR SL6000 HWSupp
UR282E
HP 5y 6h 24x7 CTR SL6000 HW Supp
UR283E
HP 5y 6h24x7 CTRw/DMR SL6000 HW Supp
UR284E
HP 3y 24x7 24h CTR SL6000 HW Sup
UR288E
HP 3y24x7 24hCTRwDMR SL6000 HW Supp
UR289E
HP 4y 24x7 24h CTR SL6000 HW Sup
UR290E
HP 4y24x7 24hCTRwDMR SL6000 HW Supp
UR291E
HP 5y 24x7 24h CTR SL6000 HW Sup
UR292E
HP 5y24x7 24hCTRwDMR SL6000 HW Supp
UR293E
HP Install SL6000 Service
UR285E
HP Startup SL6000 Service
UR286E
HP Install nonStdHrs SL6000 SVC
UR287E
Hardware Installation, Electronic
U9520E
HP LO100i Advanced Pack 3 year 24x7 Software Support
UM748E
NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack.
contents
 Overview      Standard Features      HPC Interconnects      Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Memory

HP ProLiant SL170z G6 Server
NOTE: Memory configurations listed do not apply to "Factory Integrated Models".
NOTE: Chart does not represent all possible memory configurations.
DDR3 memory population guidelines

For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator

Some DIMM installation guidelines are summarized below:

  • For servers with sixteen (16) memory slots
  • There are three (3) channels per processor; six (6) channels per server
  • There are two (3) DIMM slots for two memory channels and one (2) DIMM slots for one memory channel; sixteen (16) total slots
  • Memory channels 1 and 2 consists of the six (6) DIMMs that are furthest from the processor
  • Memory channel 3 consists of the two (2) DIMMs that are closest to the processor
  • DIMM slots that are white should be populated first
  • Do not mix Unbuffered memory (UDIMMs) with Registered memory (RDIMMs)
  • Do not install DIMMs if the corresponding processor is not installed
  • If only one processor is installed in a 2CPU system, only half of the DIMM slots are available
  • To maximize performance, balance the total memory capacity between all installed processors
  • It is not required, but it is recommended to load the channels similarly if possible
  • You can only have up to eight (8) ranks installed per channel
  • You can only install two quad-rank DIMMs per channel
  • You can only install two UDIMMs per channel; if available, the third slot in the channel must remain empty
  • Populate DIMMs from heaviest load (quad-rank) to lightest load (single-rank) within a channel
  • Heaviest load (DIMM with most ranks) within a channel goes furthest from the chipset
  • For memory mirroring mode, channel 3 must be unpopulated. Channels 1 and 2 are populated identically
  • For lock-step mode, channel 3 must be unpopulated. DIMMs in channels 1 and 2 will be installed in pairs. The paired slots will be 1,4; 2,5; 3;6 on a 3DPC system or 1,4; 2,5; on a 2DPC system
  • No mixing DIMM voltage; all DIMMs must be the same voltage
 
DIMM Type ->Registered DIMMs (RDIMMs)Unbuffered with ECC DIMMs (UDIMMs)
DIMM Rank ->Dual Rank (2R)Quad Rank (4R)Single Rank (1R)Dual Rank (2R)
DIMM Capacity ->2GB4GB8GB4GB1GB2GB
DIMM Native Speed (MHz) ->133313331066106613331333
       
SLOTS THAT CAN BE POPULATED
16 slot servers161616121212
       
MAXIMUM MEMORY CAPACITY (GB)
16 slot servers3264128481224
       
POPULATED DIMM SPEED (MHz)
1 DIMM Per Channel133313331066106613331333
2 DIMMs Per Channel10661066106680010661066
3 DIMMs Per Channel (on 2 channels)800800800

N/A

N/AN/A
 

DIMM slot and configuration diagrams
Basic memory slot & population diagram

  • Population order; start with "A" first, "B" second, "C" third, etc.
16 DIMM SLOTS (8 per CPU node)
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11A1AChnl 1
2D2D
3G3G
      
Chnl 24B4BChnl 2
5E5E
6H6H
      
Chnl 37C7CChnl 3
8F8F
 

Standard memory configuration (1 CPU model)

  • 6GB, consisting of three (3) 2GB dual-rank PC3-10600E UDIMMs
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11 A; 2GB DIMM 1A; emptyChnl 1
2 D; empty 2D; empty
3G; empty3G; empty
      
Chnl 24 B; 2GB DIMM 4B; emptyChnl 2
5 E; empty 5E; empty
6H; empty6H; empty
      
Chnl 37C; 2GB DIMM7C; emptyChnl 3
8F; empty8F; empty
 

Standard memory plus optional memory (1 CPU model)

  • 12GB, consisting of three (3) 2GB UDIMMs plus three (3) 2GB UDIMMs
    • 6x 2GB dual-rank PC3-10600E UDIMMs
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11 A; 2GB DIMM 1A; emptyChnl 1
2 D; 2GB DIMM 2D; empty
3G; empty3G; empty
      
Chnl 24 B; 2GB DIMM 4B; emptyChnl 2
5 E; 2GB DIMM 5E; empty
6H; empty6H; empty
      
Chnl 37C; 2GB DIMM7C; emptyChnl 3
8F; 2GB DIMM8F; empty
 

Standard memory replaced with optional memory (1 CPU model)
RDIMM maximum configuration

  • 64GB, consisting of eight (8) 8GB dual-rank PC3-8500 RDIMMs
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11A; 8GB DIMM1A; emptyChnl 1
2D; 8GB DIMM2D; empty
3G; 8GB DIMM3G; empty
      
Chnl 24B; 8GB DIMM4B; emptyChnl 2
5E; 8GB DIMM5E; empty
6H; 8GB DIMM6H; empty
      
Chnl 37C; 8GB DIMM7C; emptyChnl 3
8F; 8GB DIMM8F; empty
 

Standard memory replaced with optional memory (2 CPU model)
RDIMM maximum configuration

  • 128GB, consisting of sixteen (16) 8GB PC3-8500 RDIMMs
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11 A; 8GB DIMM 1 A; 8GB DIMM Chnl 1
2 D; 8GB DIMM 2 D; 8GB DIMM
3G; 8GB DIMM3G; 8GB DIMM
      
Chnl 24B; 8GB DIMM4B; 8GB DIMMChnl 2
5E; 8GB DIMM5E; 8GB DIMM
6H; 8GB DIMM6H; 8GB DIMM
      
Chnl 37 C; 8GB DIMM 7 C; 8GB DIMM Chnl 3
8F; 8GB DIMM8F; 8GB DIMM
 

UDIMM maximum configuration

  • 24GB, consisting of twelve (12) 2GB dual-rank PC3-10600 UDIMMs
 CPU1CPU2 
 slot #population orderslot #population order 
Chnl 11A; 2GB DIMM1 A; 2GB DIMM Chnl 1
2 D; 2GB DIMM 2D; 2GB DIMM
3G; empty3G; empty
      
Chnl 24

B; 2GB DIMM

4

B; 2GB DIMM

Chnl 2
5

E; 2GB DIMM

5

E; 2GB DIMM

6

H; empty

6

H; empty

      
Chnl 37 C; 2GB DIMM 7 C; 2GB DIMM Chnl 3
8F; 2GB DIMM8F; 2GB DIMM
 

NOTE: Capacity references are rounded to the common Gigabyte values.

  • 1GB = 1024MB
  • 2GB = 2048MB
  • 4GB = 4096MB
  • 8GB = 8192MB

Following are memory options available from HP:

Memory Registered DIMMs (RDIMMs)  
HP 2GB 2Rx8 PC3-10600R-9 Kit
500656-B21
HP 4GB 2Rx4 PC3-10600R-9 Kit
500658-B21
HP 4GB 4Rx8 PC3-8500R-7 LP Kit 500660-B21
HP 8GB 2Rx4 PC3-10600R-9 Kit 500662-B21
HP 8GB 2Rx4 PC3-8500R-7 Kit 516423-B21
HP 16GB 4Rx4 PC3-8500R-7 Kit 500666-B21
Unbuffered with ECC DIMMs (UDIMMs)
NOTE: Maximum 12 DIMMs supported per node
 
HP 1GB 1Rx8 PC3-10600E-9 Kit 500668-B21
HP 2GB 2Rx8 PC3-10600E-9 Kit 500670-B21
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient
 
NOTE: There is a maximum support limitation of 8 ranks per memory channel (maximum of 2 quad rank DIMMs per channel)
contents
 Overview      Standard Features      HPC Interconnects      Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Storage

1-6 Six 3.5" Non-hot plug SATA hard drive bays - Using quick release carrier
  

Drive Support


Hard Drives
NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Hard drives have either a one year or three year warranty.

SATA Entry (ETY) Drives - with Quick Release carrier
 

Quantity
Supported

Position
Supported


Controller

160GB 3G SATA 7.2K 3.5in
Up to 6
1-6
HP Embedded SATA RAID Controller
NOTE: Transfer rate: 3 Gb/s SATA

SATA Midline (MDL) Drives with Quick Release carrier
  Quantity
Supported
Position
Supported
Controller
1TB 3G SATA 7.2K 3.5in 500GB 3G SATA 7.2K 3.5in
500GB 3G SATA 7.2K 2.5in
160GB 3G SATA 7.2K 2.5in
Up to 6 1-6 HP Embedded SATA RAID Controller
NOTE: Transfer rate: 3 Gb/s SATA

SAS Enterprise (ENT) Drives - with quick-release carrier
  Quantity
Supported
Position
Supported
Controller
600GB 6G SAS 15K 3.5in
300GB 6G SAS 15K 3.5in
Up to 6 1-6 HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller.
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller.
300GB 6G SAS 10K 2.5in Up to 8 1-8 HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller.
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller.

SATA Midline (MDL) Solid State Drives - with quick-release carrier
  Quantity
Supported
Position
Supported
Controller
120GB 3G SATA 2.5in
60GB 3G SATA 2.5in
Up to 8 1-8 HP Embedded SATA RAID Controller for up to 6
NOTE: Transfer rate: 3 Gb/s SATA
HP Smart Array P410/256 MB Controller for up to 8

External Storage

 

Quantity
Supported

Position
Supported

Controller

60 Modular Smart Array
Up to 4
External
HP Smart Array P212/ 256 MB Controller
Up to 8 External HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller
70 Modular Smart Array Up to 2 External HP Smart Array P212/ 256 MB Controller
Up to 4 External HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller
contents
 Overview      Standard Features      HPC Interconnects      Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Power Specifications

HP 460W Power Supply
Part Number - AC 460W PSU
503296-B21
Input Voltage Range (Vrms) 100 to 240
Frequency Range (Nominal) (Hz) 50/60
Nominal Input Voltage (Vrms)
100
120
208
200
220
230
240
Maximum Rated Output Wattage
460
460
460
460
460
460
460
Nominal Input Current (A rms)
5.5
4.5
2.6
2.5
2.4
2.3
2.2
Max Rated Input Wattage Rating (Watts)
526
520
505
505
503
503
503
Max. Rated VA
(Volt-Amp)
548
542
527
527
524
524
524
Efficiency (%) at Max. Rated Output Wattage
87.5
88.5
91
91
91.5
91.5
91.5
Power Factor
0.97
0.97
0.97
0.97
0.97
0.97
0.97
Leakage Current (mA)
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Max. Inrush Current (A peak)
30
30
30
30
30
30
30
Max. Inrush Current duration (mS)
20
20
20
20
20
20
20
Maximum British Thermal Unit Rating (BTU-Hr)
1794
1773
1725
1725
1715
1715
1715
 
HP 750W Power Supply
Part Number - AC 750W PSU
512327-B21
Input Voltage Range (Vrms) 100 to 240
Frequency Range (Nominal) (Hz) 50/60
Nominal Input Voltage (Vrms)
100
120
208
200
220
230
240
Maximum Rated Output Wattage
750
750
750
0
750
750
750
Nominal Input Current (A rms)
8.9
7.4
4.3
4.1
3.9
3.7
3.6
Max Rated Input Wattage Rating (Watts)
857
847
824
825
820
820
820
Max. Rated VA
(Volt-Amp)
894
884
859
859
854
854
854
Efficiency (%) at Max. Rated Output Wattage
87.5
88.5
91
91
91.5
91.5
91.5
Power Factor
0.97
0.97
0.97
0.97
0.97
0.97
0.97
Leakage Current (mA)
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Max. Inrush Current (A peak)
30
30
30
30
30
30
30
Max. Inrush Current duration (mS)
20
20
20
20
20
20
20
Maximum British Thermal Unit Rating (BTU-Hr)
2925
2892
2812
2812
2797
2797
2797
 
HP 1200W Power Supply
Part Number - AC
500172-B21
Input Voltage Range (Vrms) 100 to 240
Frequency Range (Nominal) (Hz) 50/60
Nominal Input Voltage (Vrms)
100
120
208
200
220
230
240
Maximum Rated Output Wattage
800
900
1200
1200
1200
1200
1200
Nominal Input Current (A rms)
9.7
9.0
7.0
6.8
6.4
9.1
5.9
Max Rated Input Wattage Rating (Watts)
930
1034
1348
1348
1348
1348
1348
Max. Rated VA
(Volt-Amp)
970
1079
1406
1406
1406
1406
1406
Efficiency (%) at Max. Rated Output Wattage
86
87
89
89
89
89
89
Power Factor
0.97
0.97
0.97
0.97
0.97
0.97
0.97
Leakage Current (mA)
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Max. Inrush Current (A peak)
30
30
30
30
30
30
30
Max. Inrush Current duration (mS)
20
20
20
20
20
20
20
Maximum British Thermal Unit Rating (BTU-Hr)
3174
3530
4600
4600
4600
4600
4600
To review typical system power ratings use the Active Answers HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor
contents
 Overview      Standard Features      HPC Interconnects      Models      Configuration Information - Factory Integrated Models      Core Options      Additional Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Technical Specifications

System Unit
Dimensions (H x W x D)
(with bezel)
3.46 x 17.64 x 28.11 in (8.79 x 44.81 x 71.37 cm)
Weight
(approximate)
Maximum
(all hard drives, power supplies, and processors installed)
69.3 lb (31.43 kg)
Input Requirements
(per power supply)
Rated Line Voltage90 to 140 VAC
180 to 264 VAC
Rated Input Current7.31A at 115VAC
3.6A at 230VAC
Rated Input Frequency47 to 63 Hz
Rated Input Power 855W (at 100 VAC),
840.72W (at 200 VAC)
Power SpecificationsTo review typical system power ratings use the HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient
Power Supply Output
(per power supply)
Rated Steady-State Power 653.10W (at 100 VAC),
653.08W (at 200 VAC)
System Inlet TemperatureOperating50° to 95° F (10° to 35° C) at sea level with an altitude derating of 1.8°F per every 1000 ft (1.0°C per every 305 m) above sea level to a maximum of 10,000 ft (3050 m), no direct sustained sunlight. Maximum rate of change is 18°F/hr (10°C/hr). The upper limit may be limited by the type and number of options installed.
System performance may be reduced if operating with a fan fault or above 86°F (30°C).
Non-operating40° to 140° F (-40° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
Relative Humidity
(non-condensing)
Operating10% to 85% relative humidity (Rh), 82.4°F (28°C) maximum wet bulb temperature, non-condensing.
Non-operating10% to 95% relative humidity (Rh), 101.7°F (38.7°C) maximum wet bulb temperature, non-condensing.
AltitudeOperating10,000 ft (3050 m). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 1500 ft/min (457 m/min).
Non-operating30,000 ft (9144 m). Maximum allowable altitude change rate is 1500 ft/min (457 m/min).
Acoustic NoiseListed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
Idle  
   LWAd6.86
   LpAm52.36dBA
Operating  
   LWAd6.89
   LpAm52.60dBA
Emissions Classification (EMC)FCC RatingClass A
Normative StandardsCISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1
NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements.

Embedded NC362i PCIe Gigabit Server AdapterNetwork InterfaceIntegrated 10/100/1000BASE-T Transceiver
Combines a triple-speed IEEE 802.3TM - Compliant Media Access Controller (MAC) with a triple-speed Ethernet transceiver.
Data Transfer MethodCompliant to x4 PCIe Specification
Network Transfer Rate10Base-T (Half-Duplex)10 Mb/s
10Base-T (Full-Duplex)20 Mb/s
100Base-TX (Half-Duplex)100 Mb/s
100Base-TX (Full-Duplex)200 Mb/s
1000Base-TX (Half and Full-Duplex)2000Mb/s
ConnectorRJ-45 connector
Cable SupportPerforms all the physical layer functions for 10BASE-T, 100BASE-T, and 1000BASE-T Ethemet on standard Category 5 UTP

Environment-friendly Products and ApproachEnd-of-life Management and Recycling

Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner.

The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment.


© Copyright 2009 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice.

Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries.

The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less.


   DA-13332 5 - Version 5 - November 16, 2009