Overview
|
HP ProLiant SL170z Generation 6 (G6) | |||
![]() | ![]() | ||
| Open View: | Front View: | ||
| 1. | 16
DDR3 DIMM slots | 1. | Optional low profile x16 PCI-e Gen 2 |
| 2. | Up to two Intel® Quad-Core 5500 sequence processors | 2. | Serial Port |
| 3. | Six 3.5" non-hot plug hard drives using a quick release drive carrier | 3. | (2) 1Gbit NIC |
| 4. | Optional Dedicated Management port | ||
| 5. | (2) USB Ports | ||
| 6. | Power Button | ||
| 7. | Health LED | ||
| 8. | UID | ||
| 9. | Video Port | ||
| What's New |
|
|
|
| At A Glance |
The HP ProLiant SL170z is part of a new family,
HP ProLiant SL6000, of HP server solutions optimized for scale-out customers
to greatly reduce costs, maximize power efficiency, and maintain total flexibility.
The SL6000 supports up to two independent HP ProLiant SL170z G6 Servers
in the 2U HP ProLiant z6000 G6 Chassis. The servers share power supplies
and fans, providing greater power and cooling efficiencies. The HP ProLiant
SL170z G6 Server is a two socket Intel server with 16 DDR3 DIMM sockets.
|
|
|
Standard Features
|
NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - Factory Integrated Models" section. |
|
| Processor One of the following depending on Model |
Quad-Core Processor |
| Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | |
| Intel® Xeon® Processor X5560 (2.8 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo, 2/2/3/3) | |
| Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo, 2/2/3/3) | |
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor L5530 (2.40 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800) | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) | |
| Dual-Core Processors | |
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) | |
| NOTE: HT indicates
that the processor model supports Intel® Hyper-Threading Technology NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active. NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream), and "L" denotes Lower Wattage. NOTE: Up to 2 processors supported. Mixing different processor models is not supported. |
|
|
|
|
| Upgradeability | Upgradeable to two processors |
|
| |
| Chipset | Intel®
5520 Chipset NOTE: For more information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/ |
| | |
| Cache
Memory One of the following depending on Model | 8
MB (1 x 8MB) Level 3 cache NOTE: All processor models except for those identified below. |
| 4
MB (1 x 4MB) Level 3 cache NOTE: For processors L5506, E5504 and E5502. | |
|
| |
| Memory Protection | Advanced memory protection |
| | |
| Memory | Type | DDR3 Registered (RDIMM) or Unbuffered (UDIMM) | |
| Standard
(per server tray) | 6 GB (3 x 2 GB) UDIMMs | ||
| Maximum
(RDIMM) (per server tray) | 128 GB (16 x 8 GB) for Registered Memory configurations | ||
| Maximum (UDIMM) (per server tray) | 24 GB (12 x 2 GB) for Unbuffered Memory configurations | ||
| NOTE:
Depending on the memory configuration and processor model, the memory speed may
run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration
Tool at: www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient. | |||
DDR3
memory options part number decoder | |||
![]() | |||
| | |||
| Network Controller | HP NC362i Integrated Dual Port Gigabit Server Adapter |
|
| |
| Expansion Slots | Expansion Slots
# | Technology |
Bus Width** |
Connector Width |
Form Factor |
Notes |
|
1 |
PCI-Express 2.0 |
x16 |
x16 |
Low Profile |
3.3 volts | |
| ** Indicates the number of physical electrical lanes running to the connector. | ||||||
| | ||||||
| Storage Controller | HP Embedded SATA RAID Controller (RAID 0, 1, 10) per server node | |
| NOTE:
Transfer rate: 3.0 Gb/s SATA. NOTE: A HP Smart Array controller is required for SAS Hard Drives NOTE: An external diskette drive, USB floppy drive key or virtual FDD using LO100 Advanced Pack is needed to install storage controller drivers during a Windows operating system installation from a CD. NOTE: A HP Smart Array Controller is required for SAS HDD. |
||
| | ||
| Storage | Optical Drives | DVD / CD drives via USB only |
| Diskette Drives |
Via USB only | |
| Drive Bays | None ship standard | |
| Up to 6 Non-hot plug SATA or
SAS 3.5" drives Up to 8 Non-hot plug SATA, SAS, or SSD 2.5" drives (requires SFF drive cage) |
||
|
|
||
| Maximum Internal Storage | Non-Hot Plug SATA 3.5" | 6.0TB | 6 x 1TB |
| Non-Hot Plug SAS 3.5" | 1.8TB | 6 x 300GB | |
| Non-Hot Plug SATA 2.5" | 4TB | 8 x 500GB | |
| Non-Hot Plug SAS 2.5" | 2.4TB | 8 x 300GB | |
| Non-Hot Plug SSD 2.5" | 960GB | 8 x 120GB | |
|
|
|||
| Interfaces | Parallel | None |
| Network RJ-45 | 2 10/100/1000 NIC ports (1 NIC shared for the HP ProLiant Lights Out 100i Remote Management) | |
| Serial | 1 | |
| Graphics | 1 | |
| USB |
3 (two front, one internal) | |
| Management | 1 Optional Dedicated LO100i Management Port | |
| Health
LED | 1 front per server node | |
| Power | 1 front per server node | |
| UID | 1 front per server node | |
| | ||
| Graphics |
32MB shared supporting 1600x1200x16M resolution |
| | |
| Form Factor | HP ProLiant z6000 G6 Chassis - 2U Chassis can support up to two SL170z server trays in the 2U chassis |
| HP ProLiant SL170z G6 Server - 1U server tray | |
|
| |
| Embedded Manageability |
HP ProLiant Onboard Administrator Powered by LO100 with LO100i Advanced |
HP ProLiant Onboard Administrator Powered by Lights-Out 100 is standard
with this server and has LO100i Advanced Licenses for Virtual KVM and
Virtual Media available as options.
Licensed Features:
|
| | ||
| HP Insight Control management software | HP Insight Control for Linux |
HP Insight Control for Linux (IC-Linux), as a product option, delivers
essential lifecycle management that can help save time and money by integrating
discovery, server deployment, firmware updates & provisioning, health
& performance management, remote management, and virtualization. This
makes it easy to optimize your IT infrastructure through a single, simple
management console. The IC-Linux suite installs and licenses software
modules that are integrated into HP System Insight Manager (HP SIM). |
|
|
||
| Core Infrastructure Management |
HP Insight Rapid Deployment software |
HP Insight Rapid Deployment software (RDP) extends HP Systems Insight Manager with a complete deployment solution for HP ProLiant servers. RDP provides a central location (running on a Windows CMS) to configure server hardware, deploy Windows, Linux and VMware ESX operating environments and install HP ProLiant Support Pack drivers using images and scripted profiles. For more information, visit: http://www.hp.com/go/rdp. |
| HP Systems Insight Manager | HP Systems Insight Manager (HP
SIM) provides a unified, secure and extensible standards-based environment
to centrally manage servers, storage and other infrastructure devices, (both
HP and non-HP) across multiple operating system platforms. For additional information, please see: http://www.hp.com/go/insight. |
|
| Subscriber's Choice | Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides software and driver change notifications for ProLiant products. Sign up at: http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis. | |
| ROMPaq, software and latest drivers |
The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options; downloaded from Software and Drivers download pages website at: http://www.hp.com/go/support and from www.hp.com/servers/easysetup. Contains the following:
|
|
|
|
||
| Industry Standard Compliance | ACPI V2.0 Compliant |
| PCI 2.2 Compliant | |
| PXE Support | |
| WOL Support | |
| Microsoft® Logo certifications | |
| IPMI 2.0 | |
| DCMI 1.0 | |
| SMASH CLP compliant | |
| | |
| Security | Power-on password |
| Setup password | |
| Diskette boot control | |
| Secure Sockets Layer (SSL) | |
| Secure Shell (SSH) | |
| | |
| Security - Trusted Platform Module | Trusted Platform Module option kit The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to authenticate the server platform. These artifacts can include passwords, certificates and encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user data and to ensure that a server running Windows Server 2008 has not been tampered with while the system was offline. NOTE:
For more information about TPM, including a white paper, go to http://www.hp.com/go/TPM |
| | |
| Server Power Cords | One 6' Highline
(IEC-IEC) power cord ships standard NOTE: If customers require a power cord, they can check the power cord matrix for the appropriate cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix. |
| | |
| UPS
and PDU Power Cord Matrix |
Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords. |
| | |
| Power Supply | HP has a new design for ProLiant power. The new Common Slot Power Supply bay. This design provides the customer with commonality in power supplies across multiple platforms to save on the cost of spares and allows HP to offer multiple power solutions to fit the customers' needs. Many HP ProLiant Servers come with Common Slot, High Efficiency and Right-Size Power Supplies. Common Slot (CS) designates commonality of the power supply across multiple ProLiant servers. HP's new Common Slot power supplies are designed for highest efficiency to provide power efficiency without degrading performance of the ProLiant. Power Supplies will have efficiency ratings up to 92%. There are three Right Size power options available, depending on the configuration of your server. To make sure you select the correct power supply to meet your configuration, we suggest that you use the HP Power Calculator to decide the "Right-Size" for your configuration. All HP Common Slot power sources are UL, CE Mark Compliant, Hot Plug and Redundant (redundancy dependent on node configurations). |
| | |
| Common Slot ProLiant |
It is highly recommended that you use the HP Power Calculator in defining the "Right-Size" power supply for your needs. HP offers three Power Supply Options:
The HP ProLiant Common Slot Power supplies meet multiple Energy Efficiency
Initiatives: Climate Savers Computing Initiative GOLD and ECOS Consulting
80PLUS GOLD for the 460w and 750w Power Supplies and Climate Savers Computing
Initiative Silver, ECOS Consulting 80PLUS Silver for 1200w Power Supply.
HP has also been working with the EPA on developing an ENERGY STAR? Computer
Server specification and plans on offering models that meet the requirements
when they are published. Please visit the ENERGY STAR website at: www.energystar.gov
for updates on the specification development process and approved platforms. |
| | |
| System Fans | 3 system fans ship standard in z6000 chassis |
| | |
| Operating Systems and Virtualization Software Support for ProLiant Servers |
Microsoft
Windows Server |
| NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/ossupport and our driver download page www.hp.com/support/sl170zG6. | |
|
|
|
| Rack Airflow Requirements | Rack 10000 G2 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 5,350 sq cm (830 square inches) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation). Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 7 cm (2.75 inches) CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: www.hp.com/servers/SL170z. | |
| | |
| Rack Support |
HP ProLiant SL170z G6 models have two different rail kits to choose from:
For additional information, please visit: www.hp.com/go/rackandpower. |
| | |
| Factory Express Portfolio for Servers and Storage | HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to: http://www.hp.com/go/factory-express. |
|
|
|
| HP Enterprise Configurator | The HP eConfigure Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. http://www.hp.com/products/configurator |
| | |
| Service and Support |
HP Care Pack Services provide total care and support expertise with committed response designed to meet your IT and business needs. HP Care Pack Services provide total care and support expertise with committed response designed to meet your IT and business needs. HP Care Pack services include coverage for the HP branded hardware options qualified for the server that are purchased at the same time or afterward and internal to the enclosure. It also includes the 22" and smaller external monitors and tower UPS options up to 3kVA. These items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included and standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. To fully capitalize on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime. Recommended Service Simplify ProLiant solution implementation, maintenance and management.
Enhanced Service Optimize service level to increase IT performance and availability
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays. For a complete listing of service offerings and information visit: |
|
|
HPC Interconnects
| NOTE: High Performance Computing (HPC) interconnect technologies are available for the SL170z G6 under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects: http://www.hp.com/techservers/clusters/ucp/index.html | ||
|
|
||
| HPC Interconnects | InfiniBand | PCI-Express adapters |
| Gigabit Ethernet | Use embedded ports | |
|
|
Models
| Non-Hot Plug Serial
ATA (SATA) Model NOTE: Non-Hot Plug models are not upgradeable to Hot Plug. NOTE: A rail kit is not included in model - this allows for the purchase of the right size rail kit. NOTE: This Model includes two HP ProLiant SL170z Server trays. Specs below represent configuration of each tray. |
||
| HP ProLiant
SL170z G6, 2 trays, E5504, 6GB 539611-001 |
Processor(s) | (1) Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) |
| Cache Memory | 4MB shared L3 cache | |
| Memory | 6GB (3 x 2GB) PC3-10600E (UDIMM) | |
| Network Controller | HP NC362i Integrated Dual Port Gigabit Server Adapter | |
| Storage Controller | Embedded SATA RAID 0, 1, 10 | |
| Hard Drive | Optional SATA | |
| Internal Storage | Up to 6 large form factor Non-Hot Plug drives/Server tray using Quick Release carrier | |
| Power Supply | 750W | |
| Fans | 3 system fans ship standard in z6000 chassis | |
| Form Factor | One HP ProLiant z6000 G6 Chassis Two HP ProLiant SL170z G6 Server |
|
|
|
Configuration Information - Factory Integrated Models
|
NOTE: This section lists some of the steps required to configure
a Factory Integrated Model. To ensure only valid configurations are ordered,
HP recommends the use of an HP approved configurator. Contact your local
sales representative for additional information. | ||
| Step 1: Base Configuration (choose one from each list unless otherwise noted) | ||
| Chassis | HP ProLiant z6000 G6 Chassis | 538080-B21 |
| NOTE: Ships with 2U chassis and 3 fans | ||
Server Node |
HP ProLiant SL170z G6 Server NOTE: It is required that 2 server trays be purchased. NOTE: Each SL170z tray has 1 system board. |
570147-B21 |
Rail Kits | HP ProLiant z6000 G6
2U rail kit NOTE: 2U rail kit used for HP or 3rd part racks - allows addition of one z6000 chassis at a time. |
570226-B21 |
| HP
ProLiant z6000 G6 10U Bulk rail kit NOTE: 10U rail kit used for HP racks ONLY - allows addition of five z6000 chassis at a time. |
570227-B21 | |
Power Supplies |
NOTE: Refer to HP Power Advisor when selecting a power supply for your configuration, www.hp.com/go/hppoweradvisor. Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at "www.hp.com/go/proliant-energy-efficient" or www.hp.com/go/hppoweradvisor | |
| HP 460W CS HE Gold Power Supply | 503296-B21 | |
| HP 750W CS HE Gold Power Supply | 512327-B21 | |
| HP 1200W CS HE Silver Power Supply | 500172-B21 | |
| | ||
| Step 2: Choose Required Server Node Options (only one of the following from each list unless otherwise noted) | ||
| Processors | Quad-Core Processors | |
| Intel® Xeon® processor
X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO Base NOTE: If 2 processors are desired, select one 539252-L21 and one 539252-B21. |
539252-L21 | |
| Intel® Xeon® processor
X5560 (2.8 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO Base NOTE: If 2 processors are desired, select one 588191-L21 and one 588191-B21. |
588191-L21 | |
| Intel® Xeon® processor
X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO Base NOTE: If 2 processors are desired, select one 539254-L21 and one 539254-B21. |
539254-L21 |
|
| Intel® Xeon® processor
E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO Base NOTE: If 2 processors are desired, select one 539256-L21 and one 539256-B21. |
539256-L21 | |
| Intel® Xeon® processor
E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO Base NOTE: If 2 processors are desired, select one 539260-L21 and one 539260-B21. |
539260-L21
|
|
| Intel® Xeon® processor
E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO Base NOTE: If 2 processors are desired, select one 539266-L21 and one 539266-B21. |
539266-L21 | |
| Intel® Xeon® processor
L5530 (2.4 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2), FIO Base NOTE: If 2 processors are desired, select one 586601-L21 and one 586601-B21. |
586601-L21 | |
| Intel® Xeon® processor
L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2), FIO Base NOTE: If 2 processors are desired, select one 571698-L21 and one 571698-B21. |
571698-L21
|
|
| Intel® Xeon® processor
L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800), FIO Base NOTE: If 2 processors are desired, select one 571703-L21 and one 571703-B21. |
571703-L21
|
|
| Dual-Core Processors | ||
| Intel® Xeon® Processor
E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO NOTE: If 2 processors are desired, select one 571705-L21 and one 571705-B21. |
571705-L21 | |
| NOTE: HT indicates
that the processor model supports Intel® Hyper-Threading Technology. NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active. NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. |
||
|
|
||
| Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit |
500656-B21
|
|
| HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21
|
|
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit |
500660-B21
|
|
| HP 8GB 2Rx4 PC3-10600R-9 Kit |
500662-B21
|
|
| HP 8GB 2Rx4 PC3-8500R-7 Kit |
516423-B21
|
|
| HP 16GB 4Rx4 PC3-8500R-7 Kit | 500666-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) NOTE: Maximum 12 DIMMs supported per node |
||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient NOTE: There is a maximum support limitation of 8 ranks per memory channel (maximum of 2 quad rank DIMMs per channel) |
||
|
|
||
| Hard Drive | NOTE: The components
of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and
the server backplane) should operate at the same data transfer rate or the
system bandwidth will be negotiated down to an acceptable level for all
components. NOTE: Hard drives have either a one year or three year warranty. NOTE: The hard drives use a quick release carrier. NOTE: One 2 Drive SFF Drive Cage (582657-B21) is required when installing 2 SFF (2.5in) drives NOTE: When Adding SAS Drives one of the following cable kits needs to be ordered depending on which SAS controller installing - HP P212 SAS 4HDD Cable Kit 574001-B21. |
|
| SAS Enterprise (ENT) Drives - with quick-release (QR) carrier | ||
| HP 600GB 6G SAS 15K 3.5in QR DP ENT HDD | 574758-B21 | |
| HP 300GB 6G SAS 15K 3.5in QR DP ENT HDD | 585980-B21 | |
| HP 300GB 6G SAS 10K 2.5in QR DP ENT HDD | 574879-B21 | |
| SATA Entry (ETY) Drives - with quick-release (QR) carrier | ||
| HP 160GB 3G SATA 7.2K 3.5in QR ETY HDD | 574021-B21 | |
| SATA Midline (MDL) Drives - with quick-release (QR) carrier | ||
| HP 500GB 3G SATA 7.2K 3.5in QR MDL HDD | 574023-B21 | |
| HP 1TB 3G SATA 7.2K 3.5in QR MDL HDD | 574025-B21 | |
| HP 500GB 3G SATA 7.2K 2.5in QR MDL HDD | 574953-B21 | |
| HP 160GB 3G SATA 7.2K 2.5in QR MDL HDD | 574893-B21 | |
| NOTE: The HP SATA / PW CBL SL160/170 G6 KIT (574005-B21) is needed when adding more than six 2.5" hard drives. | ||
| SATA Midline (MDL) Solid State Drives - with quick-release (QR) carrier | ||
| HP 120GB 3G SATA 2.5in QR MDL SSD | 586587-B21 | |
| HP 60GB 3G SATA 2.5in QR MDL SSD | 586585-B21 | |
|
|
||
| Storage Controllers | HP P212/256 FIO SA Cntrlr w/Battery NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller (574001-B21) NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21) |
491191-B21 |
| HP Smart Array P410/ZM FIO Controller NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller (583997-B21) |
462860-B21 | |
| HP Smart Array P410/256 MB w/
Battery FIO NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller (583997-B21) NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21) |
491195-B21 | |
| HP Smart Array P411/256 MB w/
Battery FIO NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21) |
491193-B21 | |
|
|
||
| Step 3: Choose Additional Factory Integratable Options |
| NOTE: For additional options, please refer to the "Core Options" and "Additional Options" section below. |
|
|
Core Options
| NOTE: Some options may not be factory integrated. Please contact your local sales representative for additional information. | ||
| Unique Options | HP Dedicated MGT Port Kit | 517405-B21 |
| HP I/O Riser x16 SL160/170 G6 KIT |
574806-B21
|
|
| HP ProLiant z6000 Redundant Fan Kit | 538082-B21 | |
|
HP ProLiant z6000 Tray blank kit |
574551-B21 |
|
| HP ProLiant z6000 Cable Management
Kit NOTE: This is needed when using Fiber cables. |
575156-B21
|
|
| 1U Filler Panel Blank Mounting
Bracket NOTE: This is needed to mount the 1U blanking panel back with server when the server is recessed mounted. |
579069-B21 | |
| HP P212 SAS 4HDD Cable Kit NOTE: This is required when adding SAS hard drives using the P212 controller. |
574001-B21 | |
| HP P410 SAS 4HDD Cable Kit NOTE: This is required when adding SAS hard drives using the P410 controller. |
583997-B21 | |
| HP SATA / PW CBL SL160/170 G6
KIT NOTE: This is needed when adding more than six 2.5" hard drives. |
574005-B21 | |
| HP z6000 BBWC HDWR KIT NOTE: This is required when adding BBWC. |
582653-B21 | |
| 2 Drive SFF Drive Cage NOTE: This is required when adding SFF (2.5") SSD or hard drives. |
582657-B21 | |
| HP z6000 Processor / Memory Blank
Kit NOTE: This is optional to give the best cooling efficiency when server trays are not configured exactly the same in the z6000 chassis. |
579255-B21 | |
|
|
||
| Processor | Quad-Core Processors | |
| Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | 539252-B21 | |
| Intel® Xeon® Processor X5560 (2.8 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | 588191-B21 | |
| Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) |
539254-B21 |
|
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) |
539256-B21 |
|
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) |
539260-B21 |
|
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) |
539266-B21 |
|
| Intel® Xeon® Processor L5530 (2.4 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) | 586601-B21 | |
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) |
571698-B21 |
|
| Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800) |
571703-B21
|
|
| Dual-Core Processors | ||
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) |
571705-B21
|
|
| NOTE:
HT indicates that the processor model supports Intel® Hyper-Threading
Technology. NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active. NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. |
||
|
|
||
|
Memory |
Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit |
500656-B21
|
|
| HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21
|
|
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit | 500660-B21 | |
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| HP 8GB 2Rx4 PC3-8500R-7 Kit | 516423-B21 | |
| HP 16GB 4Rx4 PC3-8500R-7 Kit | 500666-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) NOTE: Maximum 12 DIMMs supported per node |
||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient |
||
| NOTE: There is a maximum support limitation of 8 ranks per memory channel (maximum of 2 quad rank DIMMs per channel) | ||
|
|
||
| Hard Drives | NOTE: The components
of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and
the server backplane) should operate at the same data transfer rate or the
system bandwidth will be negotiated down to an acceptable level for all
components. NOTE: Hard drives have either a one year or three year warranty. NOTE: The hard drives use a quick release carrier. NOTE: One 2 Drive SFF Drive Cage (582657-B21) is required when installing 2 SFF (2.5in) drives. NOTE: When adding SAS one of the following cable kits needs to be ordered depending on which SAS controller installing - HP P212 SAS 4HDD Cable Kit 574001-B21. |
|
| SAS Enterprise (ENT) Drives - with quick-release (QR) carrier | ||
| HP 600GB 6G SAS 15K 3.5in QR DP ENT HDD | 574758-B21 | |
| HP 300GB 6G SAS 15K 3.5in QR DP ENT HDD | 585980-B21 | |
| HP 300GB 6G SAS 10K 2.5in QR DP ENT HDD | 574879-B21 | |
| SATA Entry (ETY) Drives - with quick-release (QR) carrier | ||
| HP 160GB 3G SATA 7.2K 3.5in QR ETY HDD | 574021-B21 | |
| SATA Midline (MDL) Drives - with quick-release (QR) carrier | ||
| HP 500GB 3G SATA 7.2K 3.5in QR MDL HDD | 574023-B21 | |
| HP 1TB 3G SATA 7.2K 3.5in QR MDL HDD | 574025-B21 | |
| HP 500GB 3G SATA 7.2K 2.5in QR MDL HDD | 574953-B21 | |
| HP 160GB 3G SATA 7.2K 2.5in QR MDL HDD | 574893-B21 | |
| SATA Midline (MDL) Solid State Drives - with quick-release (QR) carrier | ||
| HP 120GB 3G SATA 2.5in QR MDL SSD | 586587-B21 | |
| HP 60GB 3G SATA 2.5in QR MDL SSD | 586585-B21 | |
|
|
||
| Communications | Gigabit Ethernet Adapters | |
| HP NC112T PCIe Gigabit Server Adapter | 503746-B21 | |
| HP NC360T PCI Express Dual Port Gigabit Server Adapter | 412648-B21 | |
| HP NC364T PCI Express Quad Port Gigabit Server Adapter | 435508-B21 | |
| HP NC373F PCI Express Multifunction Gigabit Server Adapter | 394793-B21 | |
| HP NC373T PCI Express Multifunction Gigabit Server Adapter | 394791-B21 | |
| HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter | 458492-B21 | |
| HP NC375T PCI Express Quad Port Gigabit Server Adapter | 538696-B21 | |
| 10 Gigabit Ethernet Adapters | ||
| HP NC522SFP Dual Port 10GbE Server
Adapter NOTE: A minimum of two Gigabytes (2 GB) of server memory is required per each NC522SFP adapter. NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately. |
468332-B21 | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs. | ||
|
|
||
| Riser Cage Options | HP I/O Riser x16 SL160/170 G6 KIT |
574806-B21 |
|
| ||
| Redundant Options | CAUTION: In ProLiant Servers that have more than one power slot (bay), only same size power supplies are recommended. If non-matched power supplies are inserted you will get errors and operation will fail. | |
| HP 460W CS HE Gold Power Supply | 503296-B21 | |
| HP 750W CS HE Gold Power Supply | 512327-B21 | |
| HP 1200W CS HE Silver Power Supply | 500172-B21 | |
| NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. |
|
|
Additional Options
| Remote Management | HP LO100i Advanced Pack, No Media 1-Server License including 1 year of 24x7 Technical Support and Updates | 530521-B21 |
| NOTE: For additional information, please see the Lights-Out 100i QuickSpecs at www.hp.com/go/lo100. | ||
| | ||
| HP Insight Control | HP Insight Control for Linux | |
| HP Insight Control for Linux, 1-server license, including one year of 24x7 Technical Support and Updates, Electronic |
T9084BAE
|
|
| HP Insight Control for Linux, No Media, 1-Server license, including one year of 24x7 Technical Support and Updates | 464423-B22 | |
| HP Insight Control for Linux,
Media pack (DVD) - No licenses included NOTE: Media pack DVD contains the ISO image for HP Insight Control for Linux, HP Systems Insight Manager, HP Insight Control power management, HP Insight Control virtual machine management, and an integrated installer. Servers must be acquired separately. |
464422-B22 | |
| NOTE: Licenses
ship without media. The Media Kit for Insight Control for Linux can be ordered
separately, or can be downloaded at: http://www.hp.com/go/ic-linux
(click on Download button). NOTE: Electronic and Flexible-Quantity licenses can be used to purchase multiple licenses with a single set of activation keys. NOTE: For additional License Kits, including electronic licensing options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_na/13019_na.html |
||
|
|
||
| Rail Options | HP ProLiant z6000 G6 2U rail kit
NOTE: 2U rail kit used for HP or 3rd part racks - allows addition of one z6000 chassis at a time. |
570226-B21
|
| HP ProLiant z6000 G6 10U Bulk
rail kit NOTE: 10U rail kit used for HP racks ONLY - allows addition of five z6000 chassis at a time. |
570227-B21
|
|
| HP SL Universal Switch Rail Kit NOTE: This kit allows you to install HP or 3rd party switch in the same rack as SL6000. |
592774-B21 | |
| HP ProCurve 6600 rail kit NOTE: This rail kit is used to mount the ProCurve 6600 switch recessed with the z6000 chassis. |
538062-B21 | |
| CISCO 4948 rail kit NOTE: This rail kit is used to mount the CISCO 4948 switch recessed with the z6000 chassis. |
574549-B21 | |
|
|
||
| Security | HP Trusted Platform Module Option Kit |
488069-B21 |
|
| ||
| Storage Controllers | SAS Controllers |
|
| Smart Array P212 Controller NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller (574001-B21). |
||
| HP Smart Array P212/Zero Memory Controller | 462828-B21 | |
| HP Smart Array P212/256 MB Controller | 462834-B21 | |
| Smart Array P410 Controller NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller (583997-B21) |
||
| HP Smart Array P410/256MB Controller | 462862-B21 | |
| HP Smart Array P410/512MB with BBWC | 462864-B21 | |
| Smart Array P411 Controller | ||
| HP Smart Array P411/256MB Controller | 462830-B21 | |
| HP Smart Array P411/512MB Battery Backed Write Cache | 462832-B21 | |
| Optional Upgrades NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21). |
||
| 256 MB Cache Module NOTE: Supported on HP Smart Array P212 Controller only. |
462968-B21 | |
| 512MB BBWC NOTE: Supported on HP Smart Array P410 Controller and HP Smart Array P411 Controller only. |
462967-B21 | |
| Battery Kit upgrade NOTE: To enable BBWC on the 256MB cache. NOTE: Supported on HP Smart Array P212 Controller. |
462969-B21 | |
| NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13203_na/13203_na.html (Smart Array P212 Controller) http://h18000.www1.hp.com/products/quickspecs/13201_na/13201_na.html (Smart Array P410 Controller) http://h18000.www1.hp.com/products/quickspecs/13202_na/13202_na.html (Smart Array P411 Controller) |
||
| SCSI HBA | ||
| HP SC11Xe Host Bus Adapter NOTE: Recommended HBA for SCSI tape drive connect. |
412911-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12566_na/12566_na.html (SCSI HBA) |
||
|
|
||
| HPC Specific Options | HP IB 4X DDR PCI-e Dual Port 0 Memory HCA | 483513-B21 |
| HP IB 4X DDR Conn-X PCI-e G2 Dual Port HCA | 483514-B21 | |
| HP IB 4X DDR PCI-e Dual Port HCA | 409376-B21 | |
| HP IB 4X DDR PCI-e DUAL PORT HCA | 448397-B21 | |
| HP IB 4X QDR CX-2 PCI-e G2 Dual Port HCA | 592520-B21 | |
| HP IB 4X DDR CX-2 PCI-e G2 Dual Port HCA | 592521-B21 | |
| NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13078_na/13078_na.html | ||
|
|
||
| StorageWorks Options | StorageWorks SCSI HBA | |
| HP U320e SCSI Host Bus Adapter NOTE: Recommended HBA for MSL SCSI Tape Library connect. |
AH627A | |
|
|
||
| HP StorageWorks Modular Smart Array | MSA SAN Storage Arrays | |
| HP StorageWorks 50 Modular Smart Array | 364430-B21 | |
| NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12245_na/12245_na.html | ||
| HP StorageWorks 60 Modular Smart Array | 418408-B21 | |
| NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12627_na/12627_na.html | ||
| HP StorageWorks 70 Modular Smart Array | 418800-B21 | |
| NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12652_na/12652_na.html | ||
|
|
||
| Uninterruptible Power Systems | HP Rack-mountable UPS | |
| HP UPS R1500 G2 UPS | ||
| HP, R1.5k VA UPS, 1U |
AF419A
|
|
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12507_na/12507_na.html |
||
|
|
||
| HP Rack Series | HP Rack 5000 Series (Graphite Metallic) | |
| HP 5642 Rack-Unassembled | 358254-B21 | |
| NOTE: Please see
the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.html |
||
| HP Rack 10000 G2 Series (Carbon/Graphite Metallic) | ||
| S10614 (14U) Rack Cabinet - Shock Pallet | 292302-B22 | |
| 10642 G2 (42U) Rack Cabinet - Pallet | AF001A | |
| 10642 G2 (42U) Rack Cabinet - Shock Pallet | AF002A | |
| 10642 G2 (42U) Rack Cabinet - Crated | AF003A | |
| 10636 G2 (36U) Rack Cabinet - Pallet | AF011A | |
| 10636 G2 (36U) Rack Cabinet - Shock Pallet | AF012A | |
| 10636 G2 (36U) Rack Cabinet - Crated | AF013A | |
| 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet | AF014A | |
| 10622 G2 (22U) Rack Cabinet - Pallet | AF021A | |
| 10622 G2 (22U) Rack Cabinet - Shock Pallet | AF022A | |
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Shock Pallet | AF034A | |
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Pallet | AF038A | |
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Pallet | AF041A | |
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Shock Pallet | AF042A | |
| 10647 G2 (47U) Rack Cabinet - Pallet | AF031A | |
| 10647 G2 (47U) Rack Cabinet 1200mm
Deep - Shock Pallet NOTE: Due to handling and shipping requirements, AF044A is only orderable through HP Factory Express. It is not for direct sales. Customer site surveys are required before an order is approved. CTO orders may require additional lead time. |
AF044A | |
| 10647 G2 (47U) Rack Cabinet 1200mm Deep - Pallet | AF045A | |
| NOTE: It is mandatory
to use a shock pallet when shipping racks with equipment installed. NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). |
||
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html |
||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
|
||
| HP Rack Options | Keyboards and Monitors | |
| TFT7600 Rackmount Keyboard Monitor | AG052A | |
| 1U Rackmount Keyboard with USB | AG072A | |
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| HP KVM Switch Options | ||
| 2x1x16 IP Console Switch with Virtual Media | AF601A | |
| 4x1x16 IP Console Switch with Virtual Media | AF602A | |
| 2x16 Server Console Switch with Virtual Media | AF600A | |
| PS/2 Virtual Media Interface Adapter,
1 pack NOTE: Requires PS/2 and one USB port on server. |
AF604A | |
| Server console switch 0x2x8 | AF616A | |
| Server console switch 0x2x16 | AF617A | |
| PS/2 Interface Adapter, 1 pack | 262588-B21 | |
| PS/2 Interface Adapter, 8 pack | 262587-B21 | |
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x4 Console Switch | ||
| HP PS2 Server Console Cable, 6 foot, 2-Pack | AF611A | |
| HP USB Server Console Cable, 6
foot, 2-Pack NOTE: Required for supporting USB peripherals. |
AF612A | |
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
| HP Serial Console Server Options | AF613A | |
| HP 16 Port Serial Console Server | AF101A | |
| HP 48 Port Serial Console Server | AF102A | |
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack | AF103A | |
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack | AF110A | |
| NOTE: Cat5e cables
are required to connect Serial Adapters to Serial Console Servers. Additional
Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. |
||
|
|
||
|
Service and Support Offerings (HP Care Pack Services) |
HP 1y 4h 13x5 SL6000 HW Support | UR258E |
| HP 1y 4h 24x7 SL6000 HW Support |
UR259E | |
| HP 1y 6h 24x7 CTR SL6000 HW Supp |
UR260E | |
| HP 3y Nbd SL6000 HW Support |
UR261E | |
| HP 3y Nbd w/DMR SL6000 HW Supp |
UR262E | |
| HP 3y 4h 13x5 SL6000 HW Support |
UR263E | |
| HP 3y 4h13x5 w/DMR SL6000 HWSupp |
UR264E | |
| HP 3y 4h 24x7 SL6000 HW Support | UR265E | |
| HP 3y 4h24x7 w/DMR SL6000 HWSupp | UR266E | |
| HP 3y 6h 24x7 CTR SL6000 HW Supp | UR267E | |
| HP 3y 6h24x7 CTRw/DMR SL6000 HWSup | UR268E | |
| HP 4y Nbd SL6000 HW Support | UR269E | |
| HP 4y Nbd w/DMR SL6000 HW Supp | UR270E | |
| HP 4y 4h 13x5 SL6000 HW Support | UR271E | |
| HP 4y 4h13x5 w/DMR SL6000 HWSupp | UR272E | |
| HP 4y 4h 24x7 SL6000 HW Support | UR273E | |
| HP 4y 4h24x7 w/DMR SL6000 HWSupp | UR274E | |
| HP 4y 6h 24x7 CTR SL6000 HW Supp | UR275E | |
| HP 4y 6h24x7 CTRw/DMR SL6000 HW Supp | UR276E | |
| HP 5y Nbd SL6000 HW Support | UR277E | |
| HP 5y Nbd w/DMR SL6000 HW Supp | UR278E | |
| HP 5y 4h 13x5 SL6000 HW Support | UR279E | |
| HP 5y 4h13x5 w/DMR SL6000 HWSupp | UR280E | |
| HP 5y 4h 24x7 SL6000 HW Support | UR281E | |
| HP 5y 4h24x7 w/DMR SL6000 HWSupp | UR282E | |
| HP 5y 6h 24x7 CTR SL6000 HW Supp | UR283E | |
| HP 5y 6h24x7 CTRw/DMR SL6000 HW Supp | UR284E | |
| HP 3y 24x7 24h CTR SL6000 HW Sup | UR288E | |
| HP 3y24x7 24hCTRwDMR SL6000 HW Supp | UR289E | |
| HP 4y 24x7 24h CTR SL6000 HW Sup | UR290E | |
| HP 4y24x7 24hCTRwDMR SL6000 HW Supp | UR291E | |
| HP 5y 24x7 24h CTR SL6000 HW Sup | UR292E | |
| HP 5y24x7 24hCTRwDMR SL6000 HW Supp | UR293E | |
| HP Install SL6000 Service | UR285E | |
| HP Startup SL6000 Service | UR286E | |
| HP Install nonStdHrs SL6000 SVC | UR287E | |
| Hardware Installation, Electronic | U9520E | |
| HP LO100i Advanced Pack 3 year 24x7 Software Support | UM748E | |
| NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack. |
|
|
Memory
| HP ProLiant SL170z G6 Server |
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
| NOTE: Chart does not represent all possible memory configurations. |
| DDR3 memory population
guidelines For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator Some DIMM installation guidelines are summarized below:
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
DIMM slot and configuration diagrams
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory configuration (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory plus optional memory (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory replaced
with optional memory (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory replaced
with optional memory (2 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| UDIMM maximum configuration
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
NOTE: Capacity references are rounded to the common Gigabyte values.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Following are memory options available from HP: |
||
| Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit |
500656-B21
|
|
| HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21
|
|
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit | 500660-B21 | |
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| HP 8GB 2Rx4 PC3-8500R-7 Kit | 516423-B21 | |
| HP 16GB 4Rx4 PC3-8500R-7 Kit | 500666-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) NOTE: Maximum 12 DIMMs supported per node |
||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient |
||
| NOTE: There is a maximum support limitation of 8 ranks per memory channel (maximum of 2 quad rank DIMMs per channel) | ||
|
|
Storage
|
| 1-6 | Six 3.5" Non-hot plug SATA hard drive bays - Using quick release carrier |
|
Drive Support | |||
|
|
|
Hard Drives |
|||
| SATA Entry (ETY) Drives - with Quick Release carrier | |||
|
Quantity |
Position |
|
|
| 160GB 3G SATA 7.2K 3.5in |
Up to 6
|
1-6
|
HP Embedded SATA RAID Controller
NOTE: Transfer rate: 3 Gb/s SATA |
|
|
|||
| SATA Midline (MDL) Drives with Quick Release carrier | |||
| Quantity Supported |
Position Supported |
Controller | |
| 1TB 3G SATA 7.2K 3.5in 500GB 3G
SATA 7.2K 3.5in 500GB 3G SATA 7.2K 2.5in 160GB 3G SATA 7.2K 2.5in |
Up to 6 | 1-6 | HP Embedded SATA RAID Controller
NOTE: Transfer rate: 3 Gb/s SATA |
|
|
|||
| SAS Enterprise (ENT) Drives - with quick-release carrier | |||
| Quantity Supported |
Position Supported |
Controller | |
| 600GB 6G SAS 15K 3.5in 300GB 6G SAS 15K 3.5in |
Up to 6 | 1-6 | HP Smart Array P212/Zero Memory
Controller HP Smart Array P212/256 MB Controller NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller. HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller. |
| 300GB 6G SAS 10K 2.5in | Up to 8 | 1-8 | HP Smart Array P212/Zero Memory
Controller HP Smart Array P212/256 MB Controller NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller. HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller. |
|
|
|||
| SATA Midline (MDL) Solid State Drives - with quick-release carrier | |||
| Quantity Supported |
Position Supported |
Controller | |
| 120GB 3G SATA 2.5in 60GB 3G SATA 2.5in |
Up to 8 | 1-8 | HP Embedded SATA RAID Controller
for up to 6 NOTE: Transfer rate: 3 Gb/s SATA HP Smart Array P410/256 MB Controller for up to 8 |
|
External Storage |
|||
|
Quantity |
Position |
Controller |
|
| 60 Modular Smart Array |
Up to 4
|
External
|
HP Smart Array P212/ 256 MB Controller |
| Up to 8 | External | HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
| 70 Modular Smart Array | Up to 2 | External | HP Smart Array P212/ 256 MB Controller |
| Up to 4 | External | HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|
Power Specifications
| HP
460W Power Supply Part Number - AC 460W PSU |
503296-B21 | ||||||
| Input Voltage Range (Vrms) | 100 to 240 | ||||||
| Frequency Range (Nominal) (Hz) | 50/60 | ||||||
| Nominal Input Voltage (Vrms) |
100
|
120
|
208
|
200
|
220
|
230
|
240
|
| Maximum Rated Output Wattage |
460
|
460
|
460
|
460
|
460
|
460
|
460
|
| Nominal Input Current (A rms) |
5.5
|
4.5
|
2.6
|
2.5
|
2.4
|
2.3
|
2.2
|
| Max Rated Input Wattage Rating (Watts) |
526
|
520
|
505
|
505
|
503
|
503
|
503
|
| Max. Rated VA (Volt-Amp) |
548
|
542
|
527
|
527
|
524
|
524
|
524
|
| Efficiency (%) at Max. Rated Output Wattage |
87.5
|
88.5
|
91
|
91
|
91.5
|
91.5
|
91.5
|
| Power Factor |
0.97
|
0.97
|
0.97
|
0.97
|
0.97
|
0.97
|
0.97
|
| Leakage Current (mA) |
0.42
|
0.50
|
0.83
|
0.87
|
0.92
|
0.96
|
1.00
|
| Max. Inrush Current (A peak) |
30
|
30
|
30
|
30
|
30
|
30
|
30
|
| Max. Inrush Current duration (mS) |
20
|
20
|
20
|
20
|
20
|
20
|
20
|
| Maximum British Thermal Unit Rating (BTU-Hr) |
1794
|
1773
|
1725
|
1725
|
1715
|
1715
|
1715
|
| HP
750W Power Supply Part Number - AC 750W PSU |
512327-B21 | ||||||
| Input Voltage Range (Vrms) | 100 to 240 | ||||||
| Frequency Range (Nominal) (Hz) | 50/60 | ||||||
| Nominal Input Voltage (Vrms) |
100
|
120
|
208
|
200
|
220
|
230
|
240
|
| Maximum Rated Output Wattage |
750
|
750
|
750
|
0
|
750
|
750
|
750
|
| Nominal Input Current (A rms) |
8.9
|
7.4
|
4.3
|
4.1
|
3.9
|
3.7
|
3.6
|
| Max Rated Input Wattage Rating (Watts) |
857
|
847
|
824
|
825
|
820
|
820
|
820
|
| Max. Rated VA (Volt-Amp) |
894
|
884
|
859
|
859
|
854
|
854
|
854
|
| Efficiency (%) at Max. Rated Output Wattage |
87.5
|
88.5
|
91
|
91
|
91.5
|
91.5
|
91.5
|
| Power Factor |
0.97
|
0.97
|
0.97
|
0.97
|
0.97
|
0.97
|
0.97
|
| Leakage Current (mA) |
0.42
|
0.50
|
0.83
|
0.87
|
0.92
|
0.96
|
1.00
|
| Max. Inrush Current (A peak) |
30
|
30
|
30
|
30
|
30
|
30
|
30
|
| Max. Inrush Current duration (mS) |
20
|
20
|
20
|
20
|
20
|
20
|
20
|
| Maximum British Thermal Unit Rating (BTU-Hr) |
2925
|
2892
|
2812
|
2812
|
2797
|
2797
|
2797
|
| HP
1200W Power Supply Part Number - AC |
500172-B21 | ||||||
| Input Voltage Range (Vrms) | 100 to 240 | ||||||
| Frequency Range (Nominal) (Hz) | 50/60 | ||||||
| Nominal Input Voltage (Vrms) |
100
|
120
|
208
|
200
|
220
|
230
|
240
|
| Maximum Rated Output Wattage |
800
|
900
|
1200
|
1200
|
1200
|
1200
|
1200
|
| Nominal Input Current (A rms) |
9.7
|
9.0
|
7.0
|
6.8
|
6.4
|
9.1
|
5.9
|
| Max Rated Input Wattage Rating (Watts) |
930
|
1034
|
1348
|
1348
|
1348
|
1348
|
1348
|
| Max. Rated VA (Volt-Amp) |
970
|
1079
|
1406
|
1406
|
1406
|
1406
|
1406
|
| Efficiency (%) at Max. Rated Output Wattage |
86
|
87
|
89
|
89
|
89
|
89
|
89
|
| Power Factor |
0.97
|
0.97
|
0.97
|
0.97
|
0.97
|
0.97
|
0.97
|
| Leakage Current (mA) |
0.42
|
0.50
|
0.83
|
0.87
|
0.92
|
0.96
|
1.00
|
| Max. Inrush Current (A peak) |
30
|
30
|
30
|
30
|
30
|
30
|
30
|
| Max. Inrush Current duration (mS) |
20
|
20
|
20
|
20
|
20
|
20
|
20
|
| Maximum British Thermal Unit Rating (BTU-Hr) |
3174
|
3530
|
4600
|
4600
|
4600
|
4600
|
4600
|
| To review typical system power ratings use the Active Answers HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor |
|
|
Technical Specifications
| System
Unit | Dimensions (H
x W x D) (with bezel) | 3.46 x 17.64 x 28.11 in (8.79 x 44.81 x 71.37 cm) | |
| Weight
(approximate) | Maximum (all hard drives, power supplies, and processors installed) | 69.3 lb (31.43 kg) | |
| Input
Requirements (per power supply) | Rated Line Voltage | 90 to 140 VAC 180 to 264 VAC | |
| Rated Input Current | 7.31A at 115VAC 3.6A at 230VAC | ||
| Rated Input Frequency | 47 to 63 Hz | ||
| Rated Input Power | 855W
(at 100 VAC), 840.72W (at 200 VAC) | ||
| Power Specifications | To review typical system power ratings use the HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient | ||
| Power Supply Output
(per power supply) | Rated Steady-State Power | 653.10W (at
100 VAC), 653.08W (at 200 VAC) | |
| System Inlet Temperature | Operating | 50°
to 95° F (10° to 35° C) at sea level with an altitude derating of
1.8°F per every 1000 ft (1.0°C per every 305 m) above sea level to a maximum
of 10,000 ft (3050 m), no direct sustained sunlight. Maximum rate of change is
18°F/hr (10°C/hr). The upper limit may be limited by the type and number
of options installed. System performance may be reduced if operating with a fan fault or above 86°F (30°C). | |
| Non-operating | 40°
to 140° F (-40° to 60° C) Maximum rate of change is 36°F/hr (20°C/hr). | ||
| Relative
Humidity (non-condensing) | Operating | 10% to 85% relative humidity (Rh), 82.4°F (28°C) maximum wet bulb temperature, non-condensing. | |
| Non-operating | 10% to 95% relative humidity (Rh), 101.7°F (38.7°C) maximum wet bulb temperature, non-condensing. | ||
| Altitude | Operating | 10,000 ft (3050 m). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 1500 ft/min (457 m/min). | |
| Non-operating | 30,000 ft (9144 m). Maximum allowable altitude change rate is 1500 ft/min (457 m/min). | ||
| Acoustic Noise | Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). | ||
| Idle | |||
| LWAd | 6.86 | ||
| LpAm | 52.36dBA | ||
| Operating | |||
| LWAd | 6.89 | ||
| LpAm | 52.60dBA | ||
| Emissions Classification (EMC) | FCC Rating | Class A | |
| Normative Standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 | ||
| NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements. | |||
|
| |||
| Embedded NC362i PCIe Gigabit Server Adapter | Network Interface | Integrated 10/100/1000BASE-T Transceiver | |
| Combines a triple-speed IEEE 802.3TM - Compliant Media Access Controller (MAC) with a triple-speed Ethernet transceiver. | |||
| Data Transfer Method | Compliant to x4 PCIe Specification | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000Mb/s | ||
| Connector | RJ-45 connector | ||
| Cable Support | Performs all the physical layer functions for 10BASE-T, 100BASE-T, and 1000BASE-T Ethemet on standard Category 5 UTP | ||
|
| |||
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
| | ||
|
© Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less. |