Overview
|
HP ProLiant DL320 Generation 6 (G6) | |||
| ![]() | ||
| Front View: | Rear View: | ||
| 1. | Cover |
1. | Power supply |
| 2. |
Non Hot Plug Dual Rotor Fans | 2. | Mouse connector |
| 3. | Optional Slim 9.5mm DVD ROM | 3. |
NIC 1 Port/Shared iLO 2 Management Port |
| 4. | USB connectors (2) | 4. |
NIC 2 Port |
| 5. | Power Button, UID button, and Front LED Indicators | 5. | Serial connector |
| 6. |
Support for up to four SATA or SAS Hard Drives or SSD's | 6. | PCI Express expansion slot 5, low-profile, half-length |
| 7. | Two PCI-Express
Slots (2 PCI-Express 2.0 x16 connectors standard) | 7. | PCI Express expansion slot 4, (optional PCI-X, full-length) |
|
8. | Processor Socket (Intel Xeon, Core 2 and Quad Core) | 8. | Dedicated Integrated Lights-Out 2 (ProLiant Onboard Administrator powered by integrated Lights-Out 2) management port (optional) |
| 9. | Nine DDR3 Memory Slots | ||
| 9. | Video connector | ||
| 10. | USB connectors (4) | ||
| 11. | Keyboard connector | ||
| What's New |
|
|
|
| At a Glance |
|
The HP ProLiant DL320 G6 Server is an enterprise rack-optimized server at an entry level price. The highly manageable 1 processor, 1U server is ideal for single-application IT infrastructure, web and edge-of-network applications. The HP infrastructure management capabilities, combined with other Insight
software, give the DL320 G6 enterprise-class management features. Support
for 1 or 2 low-cost Serial ATA drives on an integrated RAID0/1 controller,
with an optional upgrade to highly reliable hot plug SAS hard drives,
gives the DL320 G6 flexibility to meet the needs of your datacenter. Plus,
you get the cost-effective solution of a single-processor platform with
options from the new Intel® Xeon® Processor 3000 sequence with
turbo mode.
|
|
|
Standard Features
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | |
| Processor One of the following depending on Model |
Quad-Core Processors |
|
Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) |
|
| Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) | |
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3 1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800) | |
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor W3520 (2.63GHz, 8MB L3 Cache, 130W, DDR3-1066, HT, Turbo 1/1/1/2) | |
| Intel® Xeon® Processor W3540 (2.93GHz, 8MB L3 Cache, 130W, DDR3-1066, HT, Turbo 1/1/1/2) | |
| Dual-Core Processors | |
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) | |
| NOTE: HT indicates
that the processor model supports Intel® Hyper-Threading Technology. NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active. NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. ; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. |
|
|
|
|
| Cache Memory One of the following depending on Model |
4MB (1 x 4MB) Level 3 Cache |
| 8MB (1x8M) Level 3 Cache | |
|
|
|
|
Chipset | Intel 5500 Chipset NOTE: For more information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/. |
| | |
| Memory Protection | Advanced ECC |
| Mirroring mode | |
| Lock-step mode | |
| NOTE: Xeon W3500 processor family does not support any of above advanced features. | |
|
|
|
| Memory One of the following depending on Model |
Type | DDR3 1067/1333 Registered (RDIMM) and Unbuffered (UDIMM) |
| Standard (Entry Models) | 4 GB (2 x 2 GB) RDIMM | |
| Standard (High Efficiency Models) | 4 GB (2 x 2 GB) UDIMM | |
| Standard (Performance Models) | 6 GB (3 x 2 GB) RDIMM | |
| Maximum Memory | Up to 96 GB, using DDR3 Registered (RDIMM) memory, operating at 800MHz when fully populated at 2 DIMMs per Channel in 6 Slots. | |
| Up to 24 GB, using DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fully populated at 2 DIMMs per Channel in 6 slots. | ||
|
|
||
| Network Controller | Embedded NC326i Dual Port Gigabit Server Adapter |
|
|
|
| Expansion Slots | ||||||
| Expansion Slots # | Technology | Bus Width** | Connector Width | Bus
Number* | Form Factor | Notes |
5 (Standard) | PCIe | x4 | x16 | 10 | Low profile (half length, half height) slot | |
| 4 (Standard) | PCIe | x16 | x16 | 21 | Full length, full height slot | This
PCIe slot can be replaced with optional PCI-X slot below |
| 4 (Optional) | PCI-X (133MHz, 3.3Volt) | 64-bit | Not applicable | 24 | Full length, full height slot | |
| *
Default bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. | ||||||
| Storage Controllers | Entry Models | HP Smart Array B110i SATA RAID
Controller (RAID 0/1/1+0) NOTE: Transfer rate: 1.5Gb/s SATA NOTE: Hot Plug SAS and SATA controllers available via PCI card option. |
| High Efficiency Models | HP Smart Array B110i SATA RAID
Controller (RAID 0/1/1+0) NOTE: Transfer rate: 1.5Gb/s SATA NOTE: Hot Plug SAS and SATA controllers available via PCI card option. |
|
| Performance Models |
HP Smart Array P410/256MB Controller (RAID 0/1/1+0/5/5+0) |
|
|
|
||
| Storage | Optical Drive | Optional: 9.5mm DVD-ROM, or DVD RW drive | |
| Hard Drives | None ship standard | ||
| | |||
| Maximum Internal Storage Type | SATA (4HDD
models - requires optional 4HDD cage) | 4TB | 4 x 1TB |
| SAS (4HDD models - requires optional PCI controller) | 4TB | 4 x 1TB | |
| | |||
| Interfaces | Serial | 1 |
| Pointing Device (Mouse) |
1 | |
| Keyboard | 1 | |
| VGA |
1 | |
| Network RJ-45 | 2 | |
| SD Slot | 1 | |
| USB 2.0 | 7 (2 front, 1 internal (optional),
4 rear) NOTE: Please see the following URL for additional information regarding USB support. In order to connect a USB device internally, the internal USB Cable G6 Kit must be used (536769-B21). http://h18004.www1.hp.com/products/servers/platforms/usb-support.html |
|
|
|
||
| Graphics |
Integrated ATI ES1000, 32 MB video standard
NOTE: Maximum resolution available via iLO 2 remote console is 1280 x 1024. |
|
| |
| Form Factor | Rack (1U), (1.70 in/4.32 cm), 26.85" deep |
|
|
|
| HP Insight management software | HP Insight Foundation suite |
Managing the growing number of servers can be complex and expensive for
your organization. IT managers need to address changing business needs
with tools that meet the challenges of managing today's complex Datacenters.
SmartStart version supported (minimum): SmartStart 8.20 |
| ProLiant Onboard Administrator |
HP ProLiant Onboard Administrator (powered by the HP Integrated Lights-Out 2 management processor) simplifies server setup, health monitoring, power and thermal control, and lights-out remote administration of ProLiant ML, DL, and BL servers. HP ProLiant Onboard Administrator functions without additional software, and can be accessed from any location via a web browser. It works hand-in-hand with HP Systems Insight Manager, Insight Control suites, and the Insight Dynamics for ProLiant helping customers unlock the value of the ProLiant platform and deliver the highest possible quality of IT service to the business. See www.hp.com/go/ProLiantOA |
|
| HP Insight Control |
HP Insight Control, a product option, delivers essential infrastructure
management that can help save time and money by making it easy to deploy,
monitor, remote control, and optimize your IT infrastructure through a
single, simple management console. |
|
| HP Insight Dynamics for ProLiant | HP Insight Dynamics for ProLiant,
a product option, is an integrated command center that enables IT Staff
personnel to continuously analyze and optimize a converged infrastructure,
while automating and reducing the cost of common data center tasks by as
much as 40 percent. As a powerfully integrated by design toolkit to accelerate
complex technology projects and simplify daily operations that ultimately
enable IT Staff personnel to dynamically keep pace with the organizations
changing business requirements. It enables them to plan capacity and power
continuously, balance across physical and virtual resources, and ensure
cost-effective high availability. It also enables IT organizations to provision
infrastructure consistently and automatically from pools of shared resources
using a self-service portal. Resources provisioned can range from a single
virtual machine to complex multi-tier environments and their associated
physical and virtual resource requirements. In addition to the previous
functional benefits, it also provides a cost-effective disaster recovery
for physical and virtual environments that works with HP StorageWorks Continuous
Access software for both the Enterprise Virtual Array and the XP storage
array allowing application environments to be reactivated in minutes with
the touch of a button to a remote location. NOTE: For more information, visit: http://www.hp.com/go/insightdynamics |
|
|
|
||
| Industry Standard Compliance | ACPI 2.0 Compliant |
| PCI 3.0 Compliant | |
| PXE Support | |
| WOL Support | |
| Microsoft® Logo certifications | |
| USB 2.0 Support | |
| IPMI 2.0 | |
|
| |
| Intelligent Manageability | Automatic
Server Recovery (ASR) |
| | |
| Security | Power-on password USB Port control Removable optical drive assembly (optional) Removable DVD-ROM Drive Assembly (optional) Dedicated iLO2 port (optional) Serial interface control Administrator's password |
|
| |
| Security - Trusted Platform Module | Trusted Platform Module
option kit The TPM (Trusted Platform Module) is a microcontroller chip that
can securely store artifacts used to authenticate the server platform. These artifacts
can include passwords, certificates and encryption keys. Windows® BitLocker™
Drive Encryption (BitLocker) is a data protection feature available in Windows
Server® 2008. BitLocker leverages the enhanced security capabilities of a
Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help
protect user data and to ensure that a server running Windows Server 2008 has
not been tampered with while the system was offline. NOTE:
ProLiant OS pre-installed units will come with the partition required for
TPM deployment. |
| | |
| Server Power Cords | One 6' Highline (IEC-IEC) power cord ships standard |
| NOTE: HP ProLiant DL320 G6 servers ship standard with a C13 to C14 2M Highline jumper cord. If customers require a local power cord, the can check the power cord matrix for the appropriate cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix | |
|
|
|
| Power Supply | Entry Models | 400Watts, non-redundant, 72% Efficiency |
| High Efficiency Models | 500Watts, non-redundant, 92% Efficient | |
| Performance Models | (2) 400Watts, redundant hot
plug power supplies, 85% Efficient NOTE: This power supply is needed to support power capping and power monitoring. |
|
|
|
||
| Common Slot ProLiant |
HP's ProLiant Common Slot Power 460W supply meets multiple Energy Efficiency Initiatives. Climate Savers Computing Initiative GOLD, ECOS Consulting 80PLUS GOLD and plans on offering models that meet the Energy Star for Server requirements when they are published. |
| | |
| UPS and PDU Power Cord Matrix |
Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords. |
|
|
|
| System Fans | 5 dual rotor fans ship standard |
| | |
| Ultra Thin Rack Deployment Overview | For the Ultra Thin Rack Deployment Overview, including best practices for the HP ProLiant DL320 G6, please see the following URL: www.hp.com/servers/proliantdl320-g6. |
| | |
| Required Cabling | For required cabling information, refer to the Web site at: www.hp.com/servers/proliantdl320-g6. |
| | |
| Operating Systems and Virtualization Software Support for ProLiant Servers | Microsoft
Windows Server Microsoft Windows Server Hyper V Red Hat Enterprise Linux (RHEL) SUSE Linux Enterprise Server (SLES) Oracle Enterprise Linux (OEL) Solaris |
| NOTE: Support
differences will exist between the SATA and SAS configurations. NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: www.hp.com/go/ossupport and our driver download site www.hp.com/support/DL320G6. |
|
|
|
|
| Rack Airflow Requirements |
Rack 10000 G2 series Cabinets |
|
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: www.hp.com/servers/proliantdl320g6. | |
| | |
| Rack Kit |
Quick deploy rail system provides tool-free support for racks with square or round mounting holes (including Compaq/HP 7000, 9000, 10000 G2 and HP series), with an adjustment range of 24" - 36". The ambidextrous cable management arm can be mounted on either the left or right side for improved cable management. |
|
| |
| Telco Rack Support |
Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions at: http://www.hp.com/go/rackandpower |
|
| |
| HP Factory Express Capabilities |
HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to: http://www.hp.com/go/factory-express. |
| | |
| HP Enterprise Configurator | The HP eConfigure-Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. http://www.hp.com/products/configurator. |
| | |
| Service and Support |
HP Care Pack Services provide total care and support expertise with committed response times designed to meet your IT and business needs. HP Care Pack services include coverage for the HP branded hardware options qualified for the server that are purchased at the same time or afterward and internal to the enclosure. It also includes the 22-inch and smaller external monitors and tower UPS options up to 3kVA. These items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included and standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. To fully capitalizing on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of support solutions provides a range of support services designed to meet the varying needs of your business. Whether an SMB, or large global corporation, HP has ProLiant server support offers to help you speedily deploy and maximize system uptime. Recommended Service - simplify ProLiant solution implementation, maintenance, and management.
Enhanced Service - optimize service level to increase IT performance and availability.
Refer to the information on the Installation of a ProLiant on the ProLiant Data Sheet; to be delivered on a scheduled basis 8am-5pm, M-F, excluding HP holidays. NOTE: For a complete listing of service
offerings and information visit: |
|
|
Models
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | ||
| HP
DL320 G6 Entry Models HP DL320G6 E5502 | Processors | Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80 Watts, DDR3-800) |
| Cache Memory | 4MB L3 Cache | |
| Memory | 4 GB (2 x 2 GB) DDR3 RDIMM | |
| Network Controller | Embedded NC326i Dual Port Gigabit Server Adapter | |
| Storage Controller | HP Smart Array B110i SATA RAID Controller (RAID 0/1/0+1) | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 4 x 1TB 3.5" Hot
plug SATA/SAS, Maximum NOTE: SAS requires optional PCI Controller. |
|
| Optical Drive | Optional | |
| Power Supply | Auto-sensing 400-Watt PFC Power Supply, CE Mark Compliant | |
| Fans | 5 dual rotor fans ship standard | |
| Form Factor | Rack (1U), (1.70 in/4.32 cm) | |
| | ||
| HP DL320 G6
High Efficiency Models
HP DL320G6 L5506 |
Processors | Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800) |
| Cache Memory | 4MB L3 Cache | |
| Memory | 4 GB (2 x 2 GB) DDR3 UDIMM | |
| Network Controller | Embedded NC326i Dual Port Gigabit Server Adapter | |
| Storage Controller | HP Smart Array B110i SATA RAID Controller (RAID 0/1/0+1) | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 4 x 1TB 3.5" Hot
plug SATA/SAS, Maximum NOTE: SAS requires optional PCI Controller. |
|
| Optical Drive | Optional | |
| Power Supply | 500-Watt PFC Power Supply, CE Mark Compliant | |
| Fans | 5 dual rotor fans ship standard | |
| Form Factor | Rack (1U), (1.70 in/4.32 cm) | |
|
|
||
| HP DL320 G6
Performance Models HP DL320G6 E5530 505684-001
|
Processors | Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3 1066, HT, Turbo 1/1/2/2) |
| Cache Memory | 8MB L3 Cache | |
| Memory | 6 GB (3 x 2 GB) DDR3 RDIMM | |
| Network Controller | Embedded NC326i Dual Port Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410/256MB Controller | |
| Hard Drives | None ship standard | |
| Internal Storage | 4 x 1TB 3.5" Hot plug SATA/SAS | |
| Optical Drive | Optional | |
| Power Supply | (2) 400W Redundant Hot Plug Power Supply | |
| Fans | 5 dual rotor fans ship standard | |
| Form Factor | Rack (1U), (1.70 in/4.32 cm) |
|
|
Configuration Information - Factory Integrated Models
| NOTE:
This section lists some of the steps required to configure a Factory Integrated
Model. To ensure only valid configurations are ordered, HP recommends the use
of an HP approved configurator. Contact your local sales representative for information
on CTO product offerings and requirements. NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis. NOTE: FIO indicates that this option only available as a Factory Installable Option. | ||
| Step 1: Base Configuration (choose one of the following configurable models) | ||
| Models | DL320G6 CTO (Configure to Order) Chassis |
505768-B21 |
| Includes: | ||
| Embedded NC326i Dual Port Gigabit Server Adapter | ||
| 1 full length PCI Express x16 slot and 1 half length low profile PCI Express x4 slot | ||
| Integrated Lights-Out 2 (ProLiant Onboard Administrator powered by Integrated | ||
| Lights-Out 2) embedded (shared NIC functionality standard) | ||
| HP Smart Array B110i SATA RAID Controller (RAID 0/1/0+1) | ||
| Rack (1U) form factor, (1.70 in/4.32 cm) | ||
| Fixed, mounting rails | ||
| | ||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processors | Quad-Core Processors | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO |
512058-L21
|
|
| Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO |
512059-L21
|
|
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO |
512060-L21
|
|
| Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3 1066, HT, Turbo 1/1/2/2), FIO | 512061-L21 | |
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO |
512062-L21 |
|
| Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800), FIO |
512063-L21
|
|
|
Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2), FIO |
512064-L21 |
|
| Intel® Xeon® Processor W3520 (2.63GHz, 8MB L3 Cache, 130W, DDR3-1066, HT, Turbo 1/1/1/2), FIO | 519748-L21 | |
| Intel® Xeon® Processor W3540 (2.93GHz, 8MB L3 Cache, 130W, DDR3-1066, HT, Turbo 1/1/1/2), FIO | 519749-L21 | |
|
Dual-Core Processors |
||
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO |
512057-L21
|
|
| Drive Cage | HP 8SFF HDD Cage
& Bkpln G6 FIO NOTE: This cage requires the P410 SAS array controller as a Primary Controller (See Step 3 below if P/N 515938-B21 is selected). |
515938-B21 |
| HP 4LFF HDD Hot Plug
Bkpln G6 Kit FIO NOTE: This cage requires the P212 or P410 SAS array controller as a Primary Controller (See Step below if P/N 570184-B21 is selected). |
570184-B21 | |
| Power Supply | DL320G6 400W Power Supply FIO Kit | 515739-B21 |
| DL320G6 460W PL Power Supply FIO Kit | 515740-B21 | |
| DL320G6 500W NHP Power Supply FIO Kit | 537150-B21 | |
| HP 400W 1U G6 RPS Option Kit | 532092-B21 | |
| Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 |
500656-B21
|
|
| HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21
|
|
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| HP 8GB 2Rx4 PC3-8500R-7 Kit | 516423-B21 | |
| HP 16GB 4Rx4 PC3-8500R-7 Kit | 500666-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE:
Depending on the memory configuration and processor model the memory speed
may run at 1066MHz or 800MHz. See the Online Memory Configuration Tool for
details: http://www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient. |
||
|
|
||
| Step 3: Choose Additional Factory Integratable Options (only one of the following from each list unless otherwise noted) | ||
| Controllers | HP Smart Array P212/256 MB w/ Battery FIO |
491191-B21
|
| HP Smart Array P212/256MB Controller | 462834-B21 | |
| HP Smart Array P212/Zero Memory (ZM) Controller |
462828-B21
|
|
| HP Smart Array P410/Zero
Memory FIO Controller NOTE: May be selected if P/N 515938-B21 selected in Step 2 above. |
462860-B21 | |
| HP Smart Array P410/256MB
Controller NOTE: May be selected if P/N 515938-B21 selected in Step 2 above. |
462862-B21 | |
| HP Smart Array P410/256
MB w/Battery FIO NOTE: May be selected if P/N 515938-B21 selected in Step 2 above. |
491195-B21 | |
| HP Smart Array P410/512MB
with BBWC NOTE: May be selected if P/N 515938-B21 selected in Step 2 above. |
462864-B21 | |
| HP Smart Array P411/256MB Controller | 462830-B21 | |
| HP Smart Array P411/256 MB w/ Battery FIO | 491193-B21 | |
| HP Smart Array P411/512MB BBWC | 462832-B21 | |
| NOTE: Any factory integrated Smart Array Controller purchase automatically includes the HP MS HP CA MiniSAS to MiniSAS 33" Cable Kit (P/N 496014-B21). | ||
|
|
||
| Step 4: Choose Additional Options for Factory Integration | ||
| NOTE: For additional options, please refer to the "Core Options" and Additional Options section below. |
|
|
Core Options
|
NOTE: Some options may not be factory integratable. Contact your local sales representative for additional information. |
||
| Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit | 500656-B21 | |
| HP 4GB 2Rx4 PC3-10600R-9 Kit | 500658-B21 | |
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit | 500660-B21 | |
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| HP 8GB 2Rx4 PC3-8500R-7 Kit | 516423-B21 | |
| HP 16GB 4Rx4 PC3-8500R-7 Kit | 500666-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient. |
||
|
|
||
|
Optical Drives |
HP 9.5mm SATA DVD-ROM Optical Drive | 481045-B21 |
| HP 9.5mm SATA DVD RW Optical Drive | 481047-B21 | |
|
|
||
| Hard Drives | NOTE: The components
of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and
the server backplane) should operate at the same data transfer rate or the
system bandwidth will be negotiated down to an acceptable level for all
components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. |
|
| SAS Hot Plug SFF Enterprise (ENT) Drives | ||
| HP 300GB 6G SAS 10K SFF DP ENT HDD | 507127-B21 | |
| HP 300GB 3G SAS 10K SFF DP ENT HDD | 492620-B21 | |
|
HP 146GB 6G SAS 15K SFF DP ENT HDD |
512547-B21 | |
|
HP 146GB 3G SAS 15K SFF DP ENT HDD |
504062-B21 | |
| HP 146GB 6G SAS 10K SFF DP ENT HDD | 507125-B21 | |
| HP 146GB 3G SAS 10K SFF DP ENT HDD | 418367-B21 | |
| HP 72GB 6G SAS 15K SFF DP ENT HDD | 512545-B21 | |
| HP 72GB 3G SAS 15K SFF DP ENT HDD | 418371-B21 | |
| HP 72GB 3G SAS 10K SFF DP ENT HDD | 384842-B21 | |
| SAS Hot Plug 3.5" Enterprise (ENT) Drives | ||
| HP 600GB 6G SAS 15K 3.5" DP ENT HDD | 516828-B21 | |
| HP 450GB 6G SAS 15K 3.5" DP ENT HDD | 516816-B21 | |
| HP 450GB 3G SAS 15K 3.5" DP ENT HDD | 454232-B21 | |
| HP 300GB 6G SAS 15K 3.5" DP ENT HDD | 516814-B21 | |
| HP 400GB 3G SAS 10K 3.5" DP ENT HDD | 459508-B21 | |
| HP 300GB 3G SAS 15K 3.5" DP ENT HDD | 416127-B21 | |
| HP 146GB 3G SAS 15K 3.5" DP ENT HDD | 384854-B21 | |
| HP 72GB 3G SAS 15K 3.5" DP ENT HDD | 384852-B21 | |
| SAS Hot Plug SFF Midline (MDL) Drives | ||
| 500GB 6G SAS 7.2K 2.5in DP MDL HDD | 507610-B21 | |
| SAS Hot Plug 3.5" Midline (MDL) Drives | ||
| HP 1TB 3G SAS 7.2K 3.5" DP MDL HDD | 461137-B21 | |
| HP 750GB 3G SAS 7.2K 3.5" DP MDL HDD | 461135-B21 | |
| NOTE: SAS Hard
Drives are only supported with optional SAS HBA or RAID cards. NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12244_na/12244_na.html |
||
| SATA Hot Plug SFF Midline (MDL) Drives | ||
| HP 500GB 3G SATA 7.2K 2.5in MDL HDD | 507750-B21 | |
| HP 160GB 3G SATA 7.2K 2.5in MDL HDD | 530888-B21 | |
| SATA Hot Plug 3.5" Midline (MDL) Drives | ||
| HP 1TB 3G SATA 7.2K 3.5" MDL HDD | 454146-B21 | |
| HP 750GB 3G SATA 7.2K 3.5" MDL HDD | 458930-B21 | |
| HP 500GB 3G SATA 7.2K 3.5" MDL HDD | 458928-B21 | |
| HP 250GB 3G SATA 7.2K 3.5" MDL HDD | 458926-B21 | |
| SATA Hot Plug 3.5" Entry (ETY) Drives | ||
| HP 160GB 3G SATA 7.2K 3.5" ETY HDD | 458945-B21 | |
| SATA Hot Plug SFF Entry (ETY) Drives | ||
| HP 250GB 3G SATA 5.4K SFF ETY HDD | 460355-B21 | |
| HP 120GB 1.5G SATA 5.4K SFF ETY HDD | 458924-B21 | |
| NOTE: SATA hard drives have a 1-year warranty. Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_na/13021_na.html | ||
| SATA Hot Plug Midline (MDL) Solid State Drives | ||
| HP 60GB 3G SATA 2.5in MDL 1y Wty SSD | 572071-B21 | |
| HP 120GB 3G SATA 3.5in MDL 1y Wty SSD | 572073-B21 | |
| SATA Hot Plug 3.5" Midline (MDL) Solid State Drives | ||
| HP 60GB 3G SATA 2.5in MDL 1y Wty SSD | 570761-B21 | |
| HP 120GB 3G SATA 3.5in MDL 1y Wty SSD | 570763-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13415_na/13415_na.html |
||
|
|
||
|
Communications |
Gigabit Ethernet Adapters | |
| HP NC112T PCIe Gigabit Server Adapter |
503746-B21
|
|
| HP NC360T PCI Express Dual Port Gigabit Server Adapter |
412648-B21
|
|
| HP NC364T PCI Express Quad Port Gigabit Server Adapter |
435508-B21
|
|
| HP NC373F PCI Express Multifunction Gigabit Server Adapter |
394793-B21
|
|
| HP NC373T PCI Express Multifunction Gigabit Server Adapter |
394791-B21
|
|
| HP NC375T PCI Express Quad Port Gigabit Server Adapter | 538696-B21 | |
| HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter |
458492-B21
|
|
| 10 Gigabit Ethernet Adapters | ||
| HP NC522SFP Dual Port 10GbE Server
Adapter NOTE: A minimum of two Gigabytes (2 GB) of server memory is required per each NC522SFP adapter. NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately. |
468332-B21 | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs. | ||
|
|
||
| Riser Kit Options | HP 1U PCI-X Riser Option Kit | 516230-B21 |
|
|
Additional Options
| HP Insight Software | HP Insight Control server deployment | |
| HP Insight Control server deployment, Electronic License including 1 year of 24x7 Technical Support and Updates |
T9082AAE
|
|
| NOTE:
Electronic and Flexible-Quantity licenses can be used to purchase multiple
licenses with a single activation key. NOTE: Electronic software is available in all countries except China and Japan. Customers in China and Japan should order the physical equivalent. NOTE: Customer will receive a license entitlement certificate. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: Licenses ship without media. The HP Insight Control Media Kit can be ordered separately, or can be downloaded at: http://www.hp.com/go/insightupdates. NOTE: For additional license options please see the Insight Control QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12631_na/12631_na.html |
||
| HP Insight Control for Linux | ||
| HP Insight Control for Linux, 1-server license, including one year of 24x7 Technical Support and Updates, Electronic | T9084BAE | |
| HP Insight Control for Linux, No Media, 1-Server license, including one year of 24x7 Technical Support and Updates | 464423-B22 | |
| HP Insight Control
for Linux, Media pack (DVD) - No licenses included NOTE: Media pack DVD contains the ISO image for HP Insight Control for Linux, HP Systems Insight Manager, HP Insight Control power management, HP Insight Control virtual machine management, and an integrated installer. Servers must be acquired separately. |
464422-B22 | |
| NOTE:
Licenses ship without media. The HP Insight Control Media Kit can be ordered
separately, or can be downloaded at: http://www.hp.com/go/insightupdates.
NOTE: Electronic software is available in all countries except China and Japan. Customers in China and Japan should order the physical equivalent. NOTE: Electronic and Flexible-Quantity licenses can be used to purchase multiple licenses with a single set of activation keys. NOTE: For additional License Kits, including electronic licensing options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_na/13019_na.html |
||
| HP Integrated Lights-Out Advanced | ||
| HP Integrated Lights-Out
Advanced, No Media, 1-Server License, including 1 year of 24x7 Technical
Support and Updates NOTE: This license allows 1 server to be deployed and managed via HP iLO Advanced. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. |
512485-B21 | |
| NOTE: For additional license kits, including electronic delivery options, please see the ProLiant OA/iLO QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12362_na/12362_na.html | ||
| HP Insight Rapid Deployment software | ||
| HP Insight Rapid
Deployment software No Media 1-Server License, including 1 year of 24x7
Technical Support and Updates NOTE: This license allows 1 server to be deployed and managed via RDP. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. |
452151-B21 | |
| NOTE: For additional license kits, including electronic delivery options, please see the RDP QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.html | ||
|
|
||
|
Port Options |
HP DL320G6 iLO2 PORT OPT KIT |
514206-B21
|
|
|
||
|
Security | HP Trusted Platform Module Option Kit |
488069-B21 |
|
| ||
| Storage Controllers | SAS Controllers NOTE: When using the following Smart Array Controllers the HP MS HP CA MiniSAS to MiniSAS 33" Cable Kit (P/N 496014-B21) is required. |
|
| Smart Array P212 Controller | ||
| HP Smart Array P212/Zero Memory Controller |
462828-B21
|
|
| HP Smart Array P212/256 MB Controller |
462834-B21
|
|
| Smart Array P410 Controller | ||
| HP Smart Array P410/256 MB Controller | 462862-B21 | |
| HP Smart Array P410/512 MB with BBWC Controller | 462864-B21 | |
| Smart Array P411 Controller | ||
| HP Smart Array P411/256MB Controller | 482830-B21 | |
| HP Smart Array P411/512MB Battery Backed Write Cache | 462832-B21 | |
| NOTE:
Please see the following QuickSpecs for Technical Specifications and
additional information: http://h18000.www1.hp.com/products/quickspecs/13203_na/13203_na.html (Smart Array P212 Controller) http://h18000.www1.hp.com/products/quickspecs/13201_na/13201_na.html (Smart Array P410 Controller) http://h18000.www1.hp.com/products/quickspecs/13202_na/13202_na.html (Smart Array P411 Controller) |
||
| Optional Upgrades | ||
| 256 MB Cache Module NOTE: Supported on HP Smart Array P212 Controller only. |
462968-B21 | |
| 512MB BBWC NOTE: Supported on HP Smart Array P410 Controller and HP Smart Array P411 Controller only. |
462967-B21 | |
| Battery Kit upgrade NOTE: To enable BBWC on the 256MB cache. NOTE: Supported on HP Smart Array P212 Controller, HP Smart Array P410 Controller, and HP Smart Array P411 Controller only. |
462969-B21 | |
| SCSI HBA | ||
| HP SC11Xe Host Bus Adapter |
412911-B21
|
|
|
NOTE: Please see the following
QuickSpecs for Technical Specifications and additional information: |
||
|
|
||
|
Tape Drives |
NOTE: For the
complete listing of Tape Drive offerings, please see: http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html |
|
| USB Rack-Mount Tape Solutions | ||
| HP StorageWorks 1U USB Rack-Mount
Kit with one DAT 160 USB Tape Drive NOTE: Pre-configured with one DAT 160 USB tape drive. |
AG703A
|
|
| DAT 320 USB External Tape Drive | AJ823A | |
| SAS Rack-Mount Tape Solutions NOTE: HP P212 Smart Array Controller SAS (462828-B21) is recommended for a dedicated HBA for SAS tape connection. |
||
| HP StorageWorks 1U SAS Rack-Mount
Kit with one LTO-4 Ultrium 1760 NOTE: Pre-configured with one LTO-4 Ultrium 1760 SAS tape drive. |
EH946A | |
| DAT 320 WW SAS External Tape Drive | AJ828A | |
| NOTE: For an up-to-date listing of the latest O/S and software support details for HP Ultrium tape drives, please visit: http://www.hp.com/go/connect. | ||
|
|
||
|
Disk-Based Backup |
HP StorageWorks RDX Removable Disk Backup System | |
| HP StorageWorks RDX320 Internal NOTE: Requires HP 1U USB rack mount kit (A8007A) to install into 19" rack. |
AJ767A | |
| HP StorageWorks RDX500 Internal NOTE: Requires HP 1U USB rack mount kit (A8007A) to install into 19" rack. |
AJ934A | |
| NOTE: Please see
the HP RDX QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13036_na/13036_na.html |
||
|
|
||
|
Tape Autoloaders |
HP StorageWorks 1/8 G2 Tape Autoloader NOTE: HP P212 Smart Array Controller SAS (462828-B21) is recommended for a dedicated HBA for SAS tape connection. |
|
| HP StorageWorks 1/8 G2 LTO-4 Ultrium
1760 SAS Tape Autoloader NOTE: Requires HP 1/8 G2 Tape Autoloader rack kit (AH166A) to install into 19" rack. |
AK377A | |
| HP StorageWorks 1/8 G2 LTO-3 Ultrium
920 SAS Autoloader NOTE: Requires HP 1/8 G2 Tape Autoloader rack kit (AH166A) to install into 19" rack. |
AH558A | |
| NOTE: Please see the Tape Autoloader QuickSpecs at: http://www.hp.com/go/automation for additional information. | ||
|
|
||
|
Tape Libraries |
HP StorageWorks MSL2024 Tape Library | |
| HP StorageWorks MSL2024 1 LTO-4
Ultrium 1760 SAS Drive Library NOTE: HP P212 Smart Array Controller SAS (462828-B21) is recommended for a dedicated HBA for SAS tape connection. |
AK378A
|
|
| HP StorageWorks MSL2024 1 LTO-2
Ultrium 448 SCSI Drive Library NOTE: HP U320e SCSI HBA (AH627A) recommended MSL SCSI Tape Library connect. |
AG116A
|
|
| HP StorageWorks MSL4048 Tape Library | ||
| HP StorageWorks MSL4048 2 LTO-4
Ultrium 1760 SAS Drive Library NOTE: HP P212 Smart Array Controller SAS (462828-B21) is recommended for a dedicated HBA for SAS tape connection. |
AK380A
|
|
| HP StorageWorks MSL4048 1 LTO-3
Ultrium 920 SAS Drive Library NOTE: HP P212 Smart Array Controller SAS (462828-B21) is recommended for a dedicated HBA for SAS tape connection. |
AH560A
|
|
| NOTE: Please reference the MSL Tape Library QuickSpecs at: http://www.hp.com/go/automation for additional information. Please reference current compatibility information at: http://www.hp.com/go/ebs. | ||
|
|
||
|
Backup & Recovery Software |
HP Data Protector Express NOTE: One base product is required: BB117BA, BB118BA or BB117BT. Delivered as a media kit and License to Use (LTU). |
|
| HP Data Protector Express 4.0 SP1 Backup Server |
BB117BA
|
|
| HP Data Protector Express 4.0 SP1 for Microsoft Small Business Server |
BB118BA
|
|
| HP Data Protector Express Backup
Server 4.0 SP1Upgrade from Data Protector Express Single Server Edition NOTE: This part number allows registered owners of Data Protector Express Single Server Edition to acquire Data Protector Express at a reduced cost. The product received is exactly the same as when the Data Protector Express Backup Server (BB117BA) is ordered. |
BB117BT | |
| NOTE: Only one of these Data Protector Express base products is required. For available options see: http://www.hp.com/go/dataprotectorexpress | ||
| HP Data Protector Express options NOTE: These are added to one of the base products. Delivered as a License to Use (LTU). |
||
| HP Data Protector Express 4.0 SP1 Network Server Agent |
BB121BA
|
|
| HP Data Protector Express 4.0 SP1 Network Server Agent 3 Pack |
BB122BA
|
|
| HP Data Protector Express 4.0 SP1 Application Online Agent | BB125BA | |
| HP Data Protector Express 4.0 SP1 Bare Metal Disaster Recovery Option | BB128BA | |
| HP Data Protector Express 4.0 SP1 D2Any2Any Option | BB130BA | |
| HP Data Protector Express 4.0 SP1 Drive Expansion Option | BB133BA | |
|
|
||
|
HP StorageWorks Modular Smart Array |
MSA SAN Storage Arrays | |
| HP StorageWorks 60 Modular Smart Array | 418408-B21 | |
| NOTE: Please see the Modular Smart Array 60 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/12627_na/12627_na.html | ||
| HP StorageWorks 70 Modular Smart Array | 418800-B21 | |
| NOTE: Please see the Modular Smart Array 70 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/12652_na/12652_na.html | ||
|
|
||
|
HP StorageWorks Fibre Channel HBAs |
NOTE: The following
is a list of all Fibre Channel Host Bus Adapters for Windows and Linux.
For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html |
|
| Brocade Fibre Channel HBAs | ||
| HP 81B PCIe 8Gb FC Single Port HBA | AP769A | |
| HP 82B PCIe 8Gb FC Dual Port HBA | AP770A | |
| HP 41B PCIe 4Gb FC Single Port HBA | AP767A | |
| HP 42B PCIe 4Gb FC Dual Port HBA | AP768A | |
| Emulex Fibre Channel HBAs | ||
| HP StorageWorks 81E 8Gb SP PCI-e FC HBA | AJ762A | |
| HP StorageWorks 82E 8Gb Dual-port PCI-e FC HBA | AJ763A | |
| HP StorageWorks FC2142SR 4Gb PCI-e HBA | A8002A | |
| HP StorageWorks FC2242SR Dual Channel 4 Gb PCI-e HBA | A8003A | |
| HP StorageWorks FC2143 4Gb PCI-X 2.0 -to-Fibre Channel HBA | AD167A | |
| HP StorageWorks FC2243 Dual Channel 4Gb PCI-X 2.0 HBA | AD168A | |
| QLogic Fibre Channel HBAs | ||
| HP StorageWorks 81Q PCI-e FC HBA | AK344A | |
| HP StorageWorks 82Q 8Gb Dual Port PCI-e FC HBA | AJ764A | |
| HP StorageWorks FC1142SR 4Gb PCI-e HBA | AE311A | |
| HP StorageWorks FC1242SR Dual Channel 4 Gb PCI-e HBA | AE312A | |
| HP StorageWorks FC1143 4Gb PCI-X 2.0 HBA | AB429A | |
| HP StorageWorks FC1243 Dual Channel 4Gb PCI-X 2.0 HBA | AE369A | |
|
|
||
|
Uninterruptible Power Systems |
HP Rack-mountable UPS | |
| HP R1500 G2 UPS | ||
| HP, R1.5kVA UPS, 1U |
AF419A
|
|
| NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/12507_na/12507_na.html | ||
| HP R3000 UPS | ||
| HP R3000 VA UPS, 2U, Low Voltage L5-30 |
AF422A
|
|
| HP R3000 VA UPS, 2U, High Voltage L6-20 |
AF423A
|
|
| NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/10671_na/10671_na.html | ||
| HP Rack-Mountable R5500 UPS | ||
| HP R5500 VA UPS |
AF426A
|
|
| NOTE: Please
see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/11871_na/11871_na.html |
||
| NOTE: For additional information on HP Uninterruptable Power Systems please go to: www.hp.com/servers/rackups. | ||
|
|
||
| USB and SD Options | USB 1.44-MB External Diskette Drive (Carbonite) | DC141B |
| HP USB-P/S2 Mouse | DC369A | |
| HP 1GB USB 2.0 Floppy Drive Key | 442085-B21 | |
| HP 4GB SD Flash Media Kit NOTE: Blank USB and SD media device is supported for use withVMware and Citrix. USB/SD media must be installed in the internal slot of the ProLiant server. Learn more at: http://www.hp.com/go/proliantvirtualization. |
580387-B21 | |
|
|
||
| Rack Kit | Rack Adapter Kit NOTE: This kit allows HP rack servers to fit in racks that are 24" wide. | 332815-B21 | |
| HP Rack Series | HP Rack 5000 Series (Graphite Metallic) | |
| HP 5642 Rack-Unassembled | 358254-B21 | |
| NOTE: Please see
the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.html |
||
| HP Rack 10000 G2 Series (Carbon/Graphite Metallic) | ||
| 10642 G2 (42U) Rack Cabinet - Pallet | AF001A | |
| 10642 G2 (42U) Rack Cabinet - Shock Pallet | AF002A | |
| 10642 G2 (42U) Rack Cabinet - Crated | AF003A | |
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet | AF004A | |
| 10636 G2 (36U) Rack Cabinet - Pallet | AF011A | |
| 10636 G2 (36U) Rack Cabinet - Shock Pallet | AF012A | |
| 10636 G2 (36U) Rack Cabinet - Crated | AF013A | |
| 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet | AF014A | |
| 10622 G2 (22U) Rack Cabinet - Pallet | AF021A | |
| 10622 G2 (22U) Rack Cabinet - Shock Pallet | AF022A | |
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Shock Pallet | AF034A | |
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Pallet | AF038A | |
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Pallet | AF041A | |
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Shock Pallet | AF042A | |
| 10647 G2 (47U) Rack Cabinet - Pallet | AF031A | |
| HP S10614 (14U) Rack Cabinet - Shock Pallet | 292302-B22 | |
| 10647 G2 (47U) Rack Cabinet 1200mm
Deep - Shock Pallet NOTE: Due to handling and shipping requirements, AF044A is only orderable through HP Factory Express. It is not for direct sales. Customer site surveys are required before an order is approved. CTO orders may require additional lead time. |
AF044A | |
| 10647 G2 (47U) Rack Cabinet 1200mm Deep - Pallet | AF045A | |
| NOTE: It is mandatory
to use a shock pallet when shipping racks with equipment installed. NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). |
||
| NOTE: Please see
the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html |
||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
| ||
|
HP Rack Options |
Keyboards and Monitors | |
| TFT7600 Rackmount Keyboard Monitor | AG052A | |
| 1U Rackmount Keyboard with USB |
AG072A
|
|
| HP KVM Switch Options | ||
| 2 x 1 x 16 IP Console Switch with Virtual Media | AF601A | |
| 4 x 1 x 16 IP Console Switch with Virtual Media | AF602A | |
| 2 x 16 Server Console Switch with Virtual Media | AF600A | |
| PS/2 Virtual Media Interface Adapter,
1 pack NOTE: Requires PS/2 and one USB port on server. |
AF604A | |
| HP Server console switch 0x2x8 | AF616A | |
| HP Server console switch 0x2x16 | AF617A | |
| PS/2 Interface Adapter, 1 pack | 262588-B21 | |
| PS/2 Interface Adapter, 8 pack | 262587-B21 | |
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1 x 4 Console Switch | AF611A | |
| PS2 Server Console Cable, 6 ft, 2 pack | AF612A | |
| USB Server Console Cable, 6 ft,
2 pack NOTE: Required for supporting USB peripherals. |
AF613A | |
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
| HP Serial Console Server Options | ||
| HP 16 Port Serial Console Server | AF101A | |
| HP 48 Port Serial Console Server | AF102A | |
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack | AF103A | |
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack | AF110A | |
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
|
Service and Support Offerings (HP Care Pack Services) | Hardware Services On-site Service | |
| Next Business Day On-site Service, 5-Day x 9-Hour Coverage, 3 Years, Electronic |
U4479E | |
| 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic |
U4480E | |
| 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4481E | |
| 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4482E | |
| Installation & Start-up Services | ||
| Hardware Installation, Electronic |
U4490E | |
| Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays, Electronic |
U4491E | |
| Support Plus | ||
| Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic |
U4492E | |
| Support Plus 24 | ||
| Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U4493E | |
| Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic. |
U6309E | |
| Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic. |
U8331E | |
| NOTE: For more information, customer/resellers can contact: http://www.hp.com/hps/ |
|
|
Memory
|
NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
| DDR3 memory population guidelines |
| NOTE: Charts do not represent all possible memory configurations. |
| For
detailed memory configuration rules and guidelines, please use the Online
DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator
Some DIMM installation guidelines are summarized below:
|
| DDR3 DIMM slot/capacity/populated speed table | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| NOTES:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
DIMM slot and configuration diagrams
| ||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||
| Standard memory configuration
| ||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||
| Standard memory plus optional
memory
| ||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||
| Standard memory replaced
with optional memory
| ||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||
| UDIMM maximum configuration
(2 UDIMMs per Channel limit)
| ||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||
| NOTES;
For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator | ||||||||||||||||||||||||||||||||||||||
|
|
Storage
![]() |
1- 4 | Four SATA or SAS drive bays |
|
A |
Optical Drive Bay: Optional 9.5mm DVD-ROM, or DVD-RW drive |
|
Drive Support |
|||
|
Quantity |
Position |
|
|
|
Removable Media |
|||
|
All Models: |
Up to 1 |
A |
HP embedded SATA Controller |
|
|
|||
| Hard Drives NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. |
|||
| SAS Hot Plug SFF Enterprise (ENT) Drives | |||
| Quantity Supported |
Position Supported |
Controller | |
| 300GB 6G 10K DP 300GB 3G 10K DP 146GB 6G 15K DP 146GB 3G 15K DP 146GB 6G 10K DP 146GB 3G 10K DP 72GB 6G 15K DP 72GB 3G 15K DP 72GB 3G 10K DP |
Up to 8 | 1-8 | HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB with BBWC Controller |
|
|
|||
| SAS Hot Plug 3.5" Enterprise (ENT) Drives | |||
| Quantity Supported |
Position Supported |
Controller | |
| 600GB 6G 15K DP 450GB 6G 15K DP 450GB 3G 15K DP 400GB 3G 10K DP 300GB 6G 15K DP 300GB 3G 15K DP 146GB 3G 15K DP 72GB 3G 15K DP |
Up to 4 | 1-4 | HP Smart Array B110i SATA RAID
Controller with RAID 0/1/1+0 support HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB with BBWC Controller |
|
|
|||
| SAS Hot Plug SFF Midline (MDL) Drives | |||
| Quantity Supported |
Position Supported |
Controller | |
| 500GB 7.2K SFF DP | Up to 8 | 1-8 | HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB with BBWC Controller |
|
|
|||
| SAS Hot Plug 3.5" Midline (MDL) Drives | |||
| Quantity Supported |
Position Supported |
Controller | |
| 1TB SAS 7.2K DP 750GB SAS 7.2K DP |
Up to 4 | 1-4 | HP Smart Array P212/Zero Memory
Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB with BBWC Controller |
|
|
|||
| SATA Hot Plug 3.5" Midline (MDL) Drives | |||
| Quantity Supported |
Position Supported |
Controller | |
| 1TB 3G SATA 7.2K 750GB 3G SATA 7.2K 500GB 3G SATA 7.2K 250GB 3G SATA 7.2K |
Up to 4 | 1-4 | HP Smart Array B110i SATA RAID
Controller with RAID 0/1/1+0 support HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB with BBWC Controller |
|
|
|||
| SATA Hot Plug SFF Entry (ETY) Drives | |||
| Quantity Supported |
Position Supported |
Controller | |
| 250GB 3G SATA 5.4K 120GB 1.5G SATA 5.4K |
Up to 8 | 1-8 | HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB with BBWC Controller |
|
|
|||
| SATA Hot Plug SFF Midline (MDL) Drives | |||
| Quantity Supported |
Position Supported |
Controller | |
| 500GB 3G SATA 7.2K 160GB 3G SATA 7.2K |
Up to 8 | 1-8 | HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB with BBWC Controller |
|
|
|||
| SATA Hot Plug 3.5" Entry (ETY) Drives | |||
| Quantity Supported |
Position Supported |
Controller | |
| 160GB 3G SATA 7.2K | Up to 4 | 1-4 | HP Smart Array B110i SATA RAID
Controller with RAID 0/1/1+0 support HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB with BBWC Controller |
|
|
|||
| SATA Hot Plug Midline
(MDL) Solid State Drives NOTE: SSD drives requires SFF drive cage. |
|||
| Quantity Supported |
Position Supported |
Controller | |
| 60GB 3.0G SATA SSD 120GB 3.0G SATA SSD |
8 | 1-8 | HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB with BBWC Controller |
|
|
|||
| SATA Hot Plug 3.5" Midline (MDL) Solid State Drives | |||
| Quantity Supported |
Position Supported |
Controller | |
| 60GB 3.0G SATA SSD 120GB 3.0G SATA SSD |
4 | 1-4 | HP Smart Array P212/Zero Memory
Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB with BBWC Controller |
|
|
|||
|
External Storage | |||
| Quantity |
Position |
Host Controller or Adapter | |
| 60 Modular Smart Array |
Up to 8
Up to 4 |
External | HP
Smart Array P411/512 BBWC Controller HP Smart Array P212/256MB Controller |
| 70 Modular Smart Array |
Up to 4
Up to 2 |
External | HP
Smart Array P411/512 BBWC Controller HP Smart Array P212/256MB Controller |
| HP 2000sa Modular Smart Array Controller | Up to 4 | External | HP SC08Ge Host Bus Adapter |
|
| |||
| Maximum Storage Capacity – (SAS drives) | |
| Internal | 2.4 TB (4 x 600GB SAS) |
| External | 7.2TB (1 x (12 x 600GB SAS)) |
| Total | 8.6 TB |
| NOTE: In order to implement integrated SATA RAID with Smart Start 8.20 on Windows 2003, the use of a floppy drive is necessary. | |
|
| |
| Maximum Storage Capacity – (SATA Drives) | |
| Internal | 4TB (4 x 1TB SATA) |
| External | 12TB (1 x (12 x 1TB SATA)) |
| Total | 16TB |
| | |
| Tape and Disk-Based Backup | |||
| NOTE: For a complete listing of compatible tape and disk-based backup offerings, please visit: www.hp.com/go/connect |
|
Position
Supported |
Controller
|
Controller Part Number |
|
|
HP StorageWorks SCSI Tape Drives |
External
|
HP SC11Xe Host Bus Adapter
|
412911-B21
|
| HP StorageWorks USB Tape Drives DAT 40 DAT 72 DAT 160 DAT 320 1U Rack-Mount Kit |
External
|
USB 2.0 Port
|
N/A
|
| HP StorageWorks SAS Tape Drives DAT 160 DAT 320 LTO-2 Ultrium 448 LTO-3 Ultrium 920 LTO-4 Ultrium 1760 LTO-4 Ultrium 1840 1U Rack-Mount Kit 3U Rack-Mount Kit |
External
|
HP Smart Array P212/Zero Memory Controller |
462828-B21
|
| HP StorageWorks SCSI Tape Automation DAT 72x10 Autoloader 1/8 G2 Tape Autoloader MSL2024 MSL4048 MSL8096 MSL6000 |
Rack Mount
|
HP SC11Xe Host Bus Adapter
|
412911-B21
|
| HP StorageWorks SAS Tape Automation,
External 1/8 G2 Autoloader MSL2024 MSL4048 |
Rack Mount
|
HP Smart Array P212/Zero Memory Controller
|
462828-B21
|
|
HP StorageWorks Fibre Tape Automation, External |
Rack Mount
|
Please consult the EBS connectivity matrix at: http://www.hp.com/go/ebs
for detailed connectivity information.
|
N/A
|
| HP StorageWorks RDX Removable
Disk Backup System, USB RDX160 RDX320 RDX500 |
External | USB 2.0 Port | N/A |
| HP StorageWorks D2D Backup
Systems, iSCSI D2D2502i D2D2503i D2D2504i D2D4004i D2D4009i D2D4112i |
External
|
Embedded Network Controller. If the server requires a hardware iSCSI initiator, the QLogic QLA4050 Host Bus Adapter is recommended. |
N/A
|
| HP StorageWorks D2D Backup
Systems, FC D2D4004 D2D4009 D2D4112 |
External | Direct server attach is not supported, requires connection via SAN fabric. See http://www.hp.com/go/connect for supported Fibre Channel Host Bus Adapters. | N/A |
|
|
Power Specifications
| HP 500W Power Supply Part Number - AC 500W PSU |
515915-B21 Option Kit | |||||
| Input Voltage Range (Vrms) | 100 to 240 | |||||
| Frequency Range (Nominal) (Hz) | 47/63 | |||||
| Nominal Input Voltage (Vrms) | 100 | 120 | 200 | 220 | 230 | 240 |
| Maximum Rated Output Wattage | 500 | 500 | 500 | 500 | 500 | 500 |
| Nominal Input Current (A rms) | 5.74 | 4.99 | 2.86 | 2.58 | 2.46 | 2.36 |
| Max Rated Input Wattage Rating (Watts) | 568 | 568 | 562 | 556 | 556 | 556 |
| Max. Rated VA (Volt-Amp) | 574 | 574 | 573 | 567 | 567 | 567 |
| Efficiency (%) at Max. Rated Output Wattage | 88 | 88 | 89 | 90 | 90 | 90 |
| Power Factor | 0.99 | 0.99 | 0.98 | 0.98 | 0.98 | 0.98 |
| Leakage Current (mA) | 0.42 | 0.50 | 0.81 | 0.91 | 0.95 | 1.00 |
| Max. Inrush Current (A peak) | 30 | 30 | 30 | 30 | 30 | 30 |
| Max. Inrush Current duration (mS) | 20 | 20 | 20 | 20 | 20 | 20 |
| Maximum British Thermal Unit Rating (BTU-Hr) | ||||||
|
|
||||||
| HP 460W Power Supply Part Number - AC 460W PSU |
503296-B21 Option Kit | ||||||
| Input Voltage Range (Vrms) | 100 to 240 | ||||||
| Frequency Range (Nominal) (Hz) | 50/60 | ||||||
| Nominal Input Voltage (Vrms) | 100 | 120 | 200 | 208 | 220 | 230 | 240 |
| Maximum Rated Output Wattage | 460 | 460 | 460 | 460 | 460 | 460 | 460 |
| Nominal Input Current (A rms) | 5.5 | 4.5 | 2.6 | 2.5 | 2.4 | 2.3 | 2.2 |
| Max Rated Input Wattage Rating (Watts) | 526 | 520 | 505 | 505 | 503 | 503 | 503 |
| Max. Rated VA (Volt-Amp) | 548 | 542 | 527 | 527 | 524 | 524 | 524 |
| Efficiency (%) at Max. Rated Output Wattage | 87.5 | 88.5 | 91 | 91 | 91.5 | 91.5 | 91.5 |
| Power Factor | 0.97 | 0.97 | 0.97 | 0.97 | 0.97 | 0.97 | 0.97 |
| Leakage Current (mA) | 0.42 | 0.50 | 0.83 | 0.87 | 0.92 | 0.96 | 1.00 |
| Max. Inrush Current (A peak) | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
| Max. Inrush Current duration (mS) | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
| Maximum British Thermal Unit Rating (BTU-Hr) | 1794 | 1773 | 1725 | 1725 | 1715 | 1715 | 1715 |
|
|
|||||||
| HP 400W Power Supply Part Number - AC 400W PSU |
532092-B21 | ||||||
| Input Voltage Range (Vrms) | 100 to 240 | ||||||
| Frequency Range (Nominal) (Hz) | 50/60 | ||||||
| Nominal Input Voltage (Vrms) | 100 | 120 | 200 | 208 | 220 | 230 | 240 |
| Maximum Rated Output Wattage | 400 | 400 | 400 | 400 | 400 | 400 | 400 |
| Nominal Input Current (A rms) | 5.5 | 5.0 | 2.5 | 2.4 | 2.3 | 2.2 | 2.1 |
| Max Rated Input Wattage Rating (Watts) | 510 | 500 | 480 | 480 | 480 | 480 | 480 |
| Max. Rated VA (Volt-Amp) | 520 | 520 | 500 | 500 | 500 | 500 | 500 |
| Efficiency (%) at Max. Rated Output Wattage | 83.0 | 84.0 | 86.0 | 86.0 | 87.0 | 87.0 | 87.0 |
| Power Factor | 0.97 | 0.97 | 0.97 | 0.97 | 0.97 | 0.97 | 0.97 |
| Leakage Current (mA) | 0.75 | 0.75 | 0.85 | 0.90 | 0.95 | 0.95 | 1.00 |
| Max. Inrush Current (A peak) | 35 | 35 | 35 | 35 | 35 | 35 | 35 |
| Max. Inrush Current duration (mS) | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
| Maximum British Thermal Unit Rating (BTU-Hr) | 1739 | 1705 | 1636 | 1636 | 1636 | 1636 | 1636 |
|
|
|||||||
| NOTE: To review typical system power ratings use the Active Answers Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor. | |||||||
|
|
Technical Specifications
|
System Unit | Dimensions
(H x W x D) (with bezel) |
1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68.19 cm) | |
|
Weight |
Maximum |
29.95 lb (13.6kg) | |
| Minimum
(one hard drive, power supply, and processor installed) |
25.52lb (11.6kg) | ||
|
Input Requirements |
Range Line Voltage | 90
- 132 VAC, | |
|
Rated Input Current | 6
A (at 100 VAC), | ||
|
Rated Input Frequency |
47 to 63 Hz | ||
| Rated Input Power | 486 W (at 100 VAC),
479 W (at 200 VAC) | ||
| BTU Rating | Maximum | 1836
BTU/hr (at 100 VAC), 1706 BTU/hr (at 200 VAC) | |
| Power Specifications | NOTE:
To review typical system power ratings use the HP Power Advisor which is available
online located at url: www.hp.com/go/proliant-energy-efficient
or www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: DL320 G6 | ||
|
Power Supply Output |
Rated Steady-State Power |
400 W (at 100 VAC), | |
| Maximum Peak Power | 400 W (at 100 VAC),
400 W (at 200 VAC) | ||
| System Inlet Temperature | Operating | 10°
to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C
per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of
3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the type and number of options
installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). | |
|
Non-operating | -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). | ||
| Relative
Humidity (non-condensing) | Operating | 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. | |
| Non-operating | 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. | ||
|
Altitude | Operating | 3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | |
| Non-operating | 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | ||
| Acoustic Noise |
Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). | ||
| Idle | |||
|
6.25 B | ||
|
51.4dBA | ||
| Operating | |||
|
6.25 B | ||
|
51.4 dBA | ||
| Emissions Classification (EMC) | FCC Rating | Class A | |
| Normative Standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 | ||
| NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements. | |||
|
| |||
|
Power Supply |
Input voltage specifications |
Rated input voltage |
100 VAC to 240 VAC |
|
Input Specifications |
Rated input line |
90 VAC to 264VAC |
|
|
Frequency range |
47 to 63 Hz |
||
|
Rated input power |
@ 115V input, Rated input power = 486W (assume output wattage=450W |
||
|
Rated input current |
6 A, 3 A (110 V, 220 V) |
||
|
Steady state power |
420W (rated) |
||
| BTU Rating | 1710 BTU/hr | ||
| Ambient temperature range | Operating | 50° to 118° F (10° to 48° C) | |
| Non-operating | -40° to 158° F (-40° to 70° C) | ||
|
Relative humidity |
Operating |
55% to 85% | |
| Non-operating | 5% to 95% | ||
| Dielectric voltage withstand | Input to output | 1800 VAC/minute | |
| Input to ground | 1800 VAC/minute | ||
| Maximum Wet Bulb Temperature | 106.3° F (41.3° C) | ||
|
|
|||
|
Integrated Serial ATA Controller |
Simultaneous drive transfer channels | 4 channels |
| Transfer rate synchronous (maximum theoretical) | 150 MB/s per channel | |
| Data transfer method | HP Smart Array B110i SATA RAID Controller
(non-RAID mode) HP Smart Array B110i SATA RAID Controller (RAID Mode) |
|
| Drive support | Serial ATA | |
| Data transfer modes | Legacy Mode Combined Mode |
|
| Protocol | Serial ATA | |
| Feature |
NCQ (Native Command Queuing); AHCI (Advanced Host Controller Interface) | |
| RAID levels supported | 0, 1, 1+0 | |
| RAID Features | Supports multiple logical
volumes Setup through ROM based Array Configuration Utility Installation scripting support NOTE: This controller does not support Hot Plug functions or LED functions. |
|
| RAID OS Support | Microsoft Windows Server 2003/2008 NOTE: In order to implement integrated SATA RAID with Smart Start 8.20 on Windows 2003/2008, the use of a floppy drive is necessary. Linux (Red Hat, SuSE, UnitedLinux) |
|
|
|
||
|
Embedded NC326i Dual Port Gigabit Server Adapter | Network Interface | 10Base-T/ 100Base-TX/ 1000Base-TX | |
| Compatibility | IEEE 802.3 10Base-T | ||
| IEEE 802.3ab 1000Base-T | |||
| IEEE 802.3u 100Base-TX | |||
| Data Transfer Method | Four lane (x4), 100MHz PCI Express Reference Clock | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000 Mb/s | ||
| Connector | RJ-45 | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP; up to 328 ft (100 m) | |
| 10/100/1000Base-TX | Category 5 UTP; up to 328 ft (100 m) | ||
|
| |||
|
Environment-friendly Products and Approach | End-of-life Management and Recycling | Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
| | ||
|
© Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less. |