Overview
|
HP ProLiant DL585 Generation 6 (G6) | |||
| ![]() | ||
| Front View: | Rear View: | ||
| 1. | Hot Plug Redundant Fans (standard) | 1. | Redundant hot-plug power supply (optional) |
| 2. | System Insight Display | 2. |
PCI Express and PCI-X non-hot-plug expansion slots |
| 3. | Hot Plug Redundant Fans (standard) | 3. |
Hot-plug power supply (primary) |
| 4. | 1.44 MB Diskette Drive bay | 4. |
T-15 Torx screwdriver |
| 5. | DVD/CD-RW drive (standard) | 5. | NIC connector 2 |
| 6. | Front Panel LED Display (internal and external health, Unit ID light) and Power Button | 6. | NIC connector 1 |
| 7. | Integrated Lights-Out 2 (iLO 2) connector | ||
| 7. | Two USB ports | 8. | Serial connector |
| 8. | One video port | 9. | USB connectors (two) |
| 9. | Front accessible processor / memory cage | 10. | Mouse connector |
| 10. | Eight bay Small Form Factor (SFF) Serial Attached SCSI (SAS) drive cage | 11. | Keyboard connector |
| 12. | Video connector | ||
| 11. | 4U (7" Height) Rack Form Factor | 13. |
Rear UID button and LED |
| 12. | Hot Plug Redundant Power Supply | ||
| 13. | Nine PCI I/O Slots (2 64-bit/100MHz PCI-X, 4 PCI-Express x4, 3 PCI-Express x8) | ||
| 14. | Hot Plug Redundant Power Supply | ||
| 15. | Removable Top Access Panel | ||
| At A Glance |
|
Powered by Latest AMD Opteron® Six-Core Processors DL585 G6 is positioned as the leading performance 4P multi-core rack mount server with the expansion capabilities to make it ideal for server virtualization, server consolidation, multi-tiered enterprise application, and corporate infrastructure applications.
|
|
|
Standard Features
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | |
| Processor Two or four of the following depending on model |
Six-Core Processors |
| AMD Opteron™ processor Model 8439SE (2.8 GHz,105W ACP) | |
| AMD Opteron™ processor Model 8425HE (2.1 GHz, 55W ACP) | |
| AMD Opteron™ processor Model 8435 (2.6 GHz,75W ACP) | |
| AMD Opteron™ processor Model 8431 (2.4 GHz, 75W ACP) | |
| NOTE: Processor wattage references reflect Average CPU Power (ACP). For more information on ACP visit: http://www.amd.com/powernow. | |
|
|
|
| Cache Memory | 6 MB Level 3 cache memory |
|
|
|
| Upgradeability | Upgradeable to quad (4) processors |
|
|
|
| Chipset | NVIDIA NForce Professional 2200 and 2050 chipsets, and AMD-8132 chipset |
|
|
|
| Memory Protection | Advanced ECC capabilities |
|
|
|
| Memory | Type | REG PC2-6400 DIMMs (DDR2-800) |
| Standard | 16 GB (8 x 2 GB) | |
| Maximum | 256 GB (32 x 8 GB) | |
|
|
||
| Network Controller | Two embedded NC371i Multifunction Gigabit Network Adapters with TCP/IP Offload Engine, including support for Accelerated iSCSI through an optional Licensing Kit |
|
|
|
| Expansion Slots | ||||||||
| Expansion Slots # | Technology | Bus
Width | Connector Width | Bus Number | Device No. | Form Factor | Notes | |
| 1 | PCI-X | 64-bit | N/A | 66 | 1 | Full height or half length | ||
| 2 | PCI-X | 64-bit | N/A | 66 | 2 | Full length, full height | ||
| 3 | PCI-Express | x4 | x8 | 73 | 0 | Full length, full height | 100MHz | |
| 4 | PCI-Express | x4 | x8 | 76 | 0 | Full length, full height | 100MHz | |
| 5 | PCI-Express | x8 | x16 | 70 | 0 | Full length, full height | ||
| 6 | PCI-Express | x4 | x8 | 79 | 0 | Full length, full height | 100MHz | |
| 7 | PCI-Express | x8 | x16 | 2 | 0 | Full length, full height | 100MHz | |
| 8 | PCI-Express | x8 | x16 | 5 | 0 | Full length, full height | Reserved slot for Smart Array P410 Controller | |
| 9 | PCI-Express | x4 | x8 | 8 | 0 | Full height or half length | ||
| | ||||||||
| Storage Controller One of the following depending on Model |
Performance Models | HP Smart Array P410/512 MB BBWC Controller (RAID 0/1/1+0/5/5+0) |
|
|
||
| Storage Data Protection | The Battery-Backed Write Cache (BBWC) Enabler for the Smart Array P410 Controller protects up to 512-MB write cache memory from hard boot, power, controller, or system board failures. |
|
|
| NOTE: Safely transport your write cache data to another HP ProLiant DL585 G6 in the data center by removing the BBWC and Smart Array P410 Controller Memory Module simultaneously. | |
| | |
| Storage | Diskette Drive | 1.44MB Diskette Drive bay available |
| Optical Drive | Slimline DVD/CD-RW Drive Standard on some models - ejectable for security and serviceability | |
| Hard Drives | None standard | |
| Hard Disk Drive Backplane | Internal SAS backplane supports up to eight SFF hard disk drives | |
|
| ||
| Maximum Internal Storage | Hot Plug SFF SAS | 4.0 TB | 8 x 500GB SFF SAS (internal hot plug) |
| Hot Plug SFF SATA | 4.0 TB | 8 x 500GB SFF SATA (internal hot plug) | |
|
| |||
| Interfaces | Serial | 1 |
| Pointing Device (Mouse) | 1 | |
| Video | 1 front, 1 rear | |
| Keyboard | 1 | |
| USB 2.0 Ports | 2 front, 2 rear, 1 internal | |
| iLO 2 Remote Management port | 1 | |
| Network RJ-45 (Ethernet) | 2 | |
|
|
||
| Graphics | Integrated ATI RN-50 1600x1280x64K 16M color (32 MB DDR1 memory) |
|
|
|
| Form Factor | Rack (4U = 7 inches), ships
with sliding rails and cable management system Space saving form factor (4U) provides space efficiencies while providing maximum deployment flexibility |
|
|
|
|
HP Insight Management Control Software |
HP Insight Foundation |
Managing the growing number of servers can be complex and expensive for
your organization. IT managers need to address changing business needs
with tools that meet the challenges of managing today's complex Datacenters.
|
| ProLiant Onboard Administrator |
HP ProLiant Onboard Administrator (powered by the HP Integrated Lights-Out 2 management processor) simplifies server setup, health monitoring, power and thermal control, and lights-out remote administration of ProLiant ML, DL, and BL servers. HP ProLiant Onboard Administrator functions without additional software, and can be accessed from any location via a web browser. It works hand-in-hand with HP Systems Insight Manager, Insight Control suites, and the Insight Dynamics-VSE suite helping customers unlock the value of the ProLiant platform and deliver the highest possible quality of IT service to the business. See www.hp.com/go/ProLiantOA | |
| HP Insight Control | HP Insight Control,
a product option, delivers essential infrastructure management that can
help save time and money by making it easy to deploy, migrate, monitor,
remote control, and optimize your IT infrastructure through a single, simple
management console.
Two versions of Insight Control are available, to serve environments requiring either a Linux-based or a Windows-based central management server: HP Insight Control for Linux, and HP Insight Control. See www.hp.com/go/insightcontrol HP Insight Control includes one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/insight. |
|
| HP Insight Dynamics for ProLiant | HP Insight Dynamics
for ProLiant, a product option, is an integrated command center that enables
IT Staff personnel to continuously analyze and optimize a converged infrastructure,
while automating and reducing the cost of common data center tasks by as
much as 40 percent. As a powerfully integrated by design toolkit to accelerate
complex technology projects and simplify daily operations that ultimately
enable IT Staff personnel to dynamically keep pace with the organizations
changing business requirements. It enables them to plan capacity and power
continuously, balance across physical and virtual resources, and ensure
cost-effective high availability. It also enables IT organizations to provision
infrastructure consistently and automatically from pools of shared resources
using a self-service portal. Resources provisioned can range from a single
virtual machine to complex multi-tier environments and their associated
physical and virtual resource requirements. In addition to the previous
functional benefits, it also provides a cost-effective disaster recovery
for physical and virtual environments that works with HP StorageWorks Continuous
Access software for both the Enterprise Virtual Array and the XP storage
array allowing application environments to be reactivated in minutes with
the touch of a button to a remote location.
NOTE: For more information, visit: |
|
| | ||
| Industry Standard Compliance | ACPI 1.0a. Compliant |
| PCI 2.2 Compliant | |
| PXE Support | |
| WOL Support (with embedded NC371i Multifunction Gigabit Network Adapters) | |
| Physical Address Extension (PAE) Support | |
| Microsoft® Logo certifications | |
| USB 2.0 Support | |
|
|
|
| Intelligent Manageability | HP Systems Insight Manager software SmartStart Redundant ROM Remote Flash ROM Management Agents Integrated Management Log (IML) Automatic Server Recovery-2 (ASR-2) ROM-Based Setup Utility (RBSU) Dynamic Sector Repairing (with Smart Array Controllers) Drive Parameter Tracking (with Smart Array Controllers) Pre-Failure Warranty (covers processors, SAS hard drives and memory) Redundant/adaptive load balancing NIC Support |
|
|
|
| Availability |
|
|
|
|
| Serviceability |
|
| | |
| Security | Power-on password Keyboard password Diskette drive control enable/disable Diskette boot control enable/disable External USB port enable/disable Network Server Mode Serial interface control Administrator's password Removable optical drive |
| | |
| Server Power Cords | The HP ProLiant DL585 G6 servers ship standard with a 6-foot IEC 320-C14 to IEC320-C19 jumper cord. If you require a power cord, please check the Power Specifications below for the appropriate power cord, or consult the Power Cord Matrix: http://www.hp.com/products/powercords |
| | |
| UPS and PDU Power Cord Matrix | Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Power Cords, click on the HP Power Cord Matrix link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords. |
| | |
| Power Supply | 910W (low line), 1300W (high
line) with 12V main output. Size is 2.8"(H) X 4.9"(W) X 7.5"(L).
NOTE: One Hot Plug Power Supply ships with Standard Models (optional Redundant Hot Plug Power Supply Option Kit available). High Performance models ship with two Hot Plug Power Supplies. |
| | |
| System Fans | 6 Hot plug, redundant fans (individually removable) |
|
|
|
| Operating Systems and Virtualization Software Support for ProLiant Servers |
Microsoft
Windows Server 2003 R2 |
| | |
| Rack Airflow Requirements | Rack 10000 G2 series Cabinets |
|
The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. |
|
| CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: | |
| |
| CAUTION: Always
use blanking panels to fill all remaining empty front panel U-spaces in
the rack. This arrangement ensures proper airflow. Using a rack without
blanking panels results in improper cooling that can lead to thermal damage.
NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: www.hp.com/servers/dl585. |
|
| | |
| Rack Kit |
Quick deploy rail system provides tool-free support for racks with square or round mounting holes (including Compaq/HP 7000, 9000, 10000 G2 and HP series), with an adjustment range of 24" - 36". The ambidextrous cable management arm can be mounted on either the left or right side for improved cable management. |
| | |
| Telco Rack Support |
Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions at: http://www.racksolutions.com/hp/ |
| | |
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and
deployment services for HP servers and storage products. Customers can
choose how their factory solutions are built, tested, integrated, shipped
and deployed. |
| | |
| HP Enterprise Configurator |
The HP eConfigure Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. For additional information please visit: http://www.hp.com/products/configurator |
| | |
| Service and Support |
HP Care Pack Services provide total care and support expertise with
committed response designed to meet your IT and business needs.
Enhanced Service - optimize service level to increase IT performance
and availability.
Refer to the information on "Installation & Start-Up" for
service on ProLiant server and Microsoft or Linux O/S per the Customer
Description and/or Data Sheet; to be delivered on a scheduled basis 8am-5pm,
M-F, excluding HP holidays. |
|
|
Solutions
| Solutions | Designed for enterprise customers running compute- or I/O intensive database and transaction applications, as well as data centers using virtualization and consolidation to reduce server sprawl, the rack optimized 4-processor HP ProLiant DL585 G6 server delivers maximum performance and high availability for highly complex, business critical applications. Specifically, the HP ProLiant DL585 G6 would be excellent for running the following types of applications: |
| Typical Usage: | |
|
|
|
HPC Interconnects
| NOTE: High Performance Computing (HPC) interconnect technologies are available for this server under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects: http://www.hp.com/techservers/clusters/ucp/index.html | ||
| HPC Interconnect | InfiniBand | PCI-X and PCI-Express adapters |
| Gigabit Ethernet | Use embedded ports | |
| Myrinet XP | PCI-X Rev D and Rev E adapters | |
|
|
Models
| HP DL585 G6
Performance Models HP ProLiant DL585 G6 8439SE 2.8GHz Six Core 4P 16GB 512BBWC Rack Server 539842-001 |
Processors | AMD Opteron™ 8439SE processor Model (2.8 GHz, 105W ACP) |
| Cache Memory | 6MB shared L3 cache per processor | |
| Memory | 16GB (8 x 2GB) | |
| Network Controller | Two embedded NC371i Multifunction Gigabit Network Adapters | |
| Storage Controller | Smart Array P410/512 MB BBWC Controller (Raid 0,1,1+0, 5, 5+0) | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 4TB of internal storage | |
| Optical Drive | Slimline DVD/CD-RW Drive (8X/24X) (ejectable) | |
| Power Supply | Redundant standard on performance models | |
| Form Factor | Rack 4U | |
|
|
||
| HP
ProLiant DL585 G6 8439SE 2.8GHz Six Core 4P 16GB 512BBWC ICE Rack Server 577143-001 | Processors | AMD Opteron™ 8439SE processor Model (2.8 GHz, 105W ACP) |
| Cache Memory | 6MB shared L3 cache per processor | |
| Memory | 16GB (8 x 2GB) | |
| Network Controller | Two embedded NC371i Multifunction Gigabit Network Adapters | |
| Storage Controller | Smart Array P410/512 MB BBWC Controller (Raid 0,1,1+0, 5, 5+0) | |
| Manageability | HP Insight Control Management Suites | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 4TB of internal storage | |
| Optical Drive | Slimline DVD/CD-RW Drive (8X/24X) (ejectable) | |
| Power Supply | Redundant standard on performance models | |
| Form Factor | Rack 4U | |
| | ||
| HP ProLiant
DL585 G6 8431 2.4GHz Six Core 4P 16GB 512BBWC Rack Server 539843-001 |
Processors | 6-Core AMD Opteron™ 8400 Series Processors |
| Cache Memory | 6MB shared L3 cache per processor | |
| Memory | 16GB (8 x 2GB) | |
| Network Controller | Two embedded NC371i Multifunction Gigabit Network Adapters | |
| Storage Controller | Smart Array P410/512 MB BBWC Controller (Raid 0,1,1+0, 5, 5+0) | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 4TB of internal storage | |
| Optical Drive | Slimline DVD/CD-RW Drive (8X/24X) (ejectable) | |
| Power Supply | Redundant standard on performance models | |
| Form Factor | Rack 4U |
|
|
Configuration Information - Factory Integrated Models
| NOTE:
This section lists some of the steps required to configure a Factory Integrated
Model. To ensure only valid configurations are ordered, HP recommends the
use of an HP approved configurator. Contact your local sales representative
for information on CTO product offerings and requirements. NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis. NOTE: FIO indicates that this option only available as a Factory Installable Option. |
||
| Step 1: Base Configuration | ||
| Models | HP ProLiant DL585 G6 Rack CTO Chassis |
574409-B21
|
| Factory Integrated Models ship with: | ||
|
Two embedded NC371i Multifunction Gigabit Network Adapters | ||
| | ||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processors | Six-Core Processors | |
| AMD Opteron™ 8431 six-core processor (2.4 GHz, 75W ACP) 2p option kit, FIO | 539848-L21 | |
| AMD Opteron™ 8435 six-core processor (2.6 GHz, 75W ACP) 2p option kit, FIO | 572373-L21 | |
| AMD Opteron™ 8439SE six-core processor (2.8 GHz, 105W ACP) 2p option kit, FIO | 539847-L21 | |
| AMD Opteron™ 8425HE six-core processor (2.1 GHz, 55W ACP) 2p option kit, FIO | 539849-L21 | |
|
|
||
| Base Memory | 2 GB REG PC2-6400 2 x 1 GB Kit |
497763-B21
|
| 4 GB REG PC2-6400 2 x 2 GB Kit |
497765-B21
|
|
| 8 GB REG PC2-6400 2 x 4 GB Kit | 497767-B21 | |
| 8 GB REG PC2-6400 2 x 4 GB Low Power Kit | 504351-B21 | |
| 16 GB REG PC2-5300 2 x 8 GB | 408855-B21 | |
| 64 GB REG PC2-5300 8 x 8 GB | 495605-B21 | |
| NOTE:
Memory must be installed in like-pairs, i.e. two of the same size. NOTE: Memory bus speeds will operate as follows: 2-4 DIMMs at 800MHz; 6 at 667MHz; 8 at 533MHz. |
||
|
|
||
| Storage Controllers | HP Smart Array P410/256 MB Controller |
462862-B21
|
| HP Smart Array P410/512
MB with BBWC Controller |
462864-B21 | |
| HP Smart Array P410/ZM FIO Controller | 462860-B21 | |
| HP Smart Array P410/256 FIO Cntrlr w/Battery | 491195-B21 | |
|
|
||
| Step 3: Choose Additional Options for Factory Integration | ||
| NOTE: For additional options, please refer to the "Core Options and Additional Options" section below. |
|
|
Core Options
| NOTE: Some options may not be available for factory integration. Please contact an HP sales representative for additional information. | ||
| Unique Options | HP O8431 DL585G6 Kit | 539848-B21 |
| HP O8435 DL585G6 Kit | 572373-B21 | |
| HP O8425HE DL585G6 2P Kit | 539849-B21 | |
| HP O8439SE DL585G6 2P Kit | 539847-B21 | |
| HP DL585 Video Power Cable | 576444-B21 | |
|
|
||
| Processors | Six-Core Processors | |
| AMD Opteron™ 8431 2.40GHz Six Core 75 Watts DL585 G6 Processor Option Kit | 539848-B21 | |
| AMD Opteron™ 8435 2.60GHz Six Core 75 Watts DL585 G6 Processor Option Kit | 572373-B21 | |
| AMD Opteron™ 8425HE 2.10GHz Six Core 55 Watts DL585 G6 Processor Option Kit | 539849-B21 | |
| AMD Opteron™ 8439SE 2.80GHz Six Core 105 Watts DL585 G6 Processor Option Kit | 539847-B21 | |
|
|
||
|
Memory |
Registered DIMMs | |
| HP 2GB Registered PC2-6400 2x1GB DDR2 Memory Kit | 497763-B21 | |
| HP 4GB Registered PC2-6400 2x2GB DDR2 Memory Kit | 497765-B21 | |
| HP 8GB Registered PC2-6400 2x4GB DDR2 Memory Kit | 497767-B21 | |
| HP 8GB Registered PC2-6400 2x4GB Low Power DDR2 Memory Kit | 504351-B21 | |
| HP 16GB Registered PC2-5300 2x8GB DDR2 Memory Kit | 408855-B21 | |
| HP 64GB Registered PC2-5300 8x8GB DDR2 Memory Kit | 495605-B21 | |
| NOTE: Memory must
be installed in like-pairs, i.e. two of the same size. NOTE: Memory bus speeds will operate as follows: 2-4 DIMMs at 800MHz; 6 at 667MHz; 8 at 533MHz. |
||
|
|
||
| Optical Drives | HP 8X/24X SlimLine DVD-ROM Drive | 264007-B21 |
| HP 8X Slim DVD+RW Drive | 383975-B21 | |
| HP Slimline CD-RW/DVD-ROM 24X Carbon Combo Drive | 331903-B21 | |
| NOTE: Optical drives are ejectable. | ||
|
|
||
| Hard Drives | SAS Hot Plug SFF Enterprise (ENT)
Drives |
|
| HP 300GB 6G SAS 10K SFF (2.5-inch)
Dual Port Enterprise 3yr Warranty Hard Drive |
507127-B21 | |
| HP 300GB 3G SAS 10K SFF (2.5-inch)
Dual Port Enterprise 3yr Warranty Hard Drive |
492620-B21 | |
| HP 146GB 6G SAS 15K SFF (2.5-inch)
Dual Port Enterprise 3yr Warranty Hard Drive |
512547-B21 | |
| HP 146GB 3G SAS 15K SFF (2.5-inch)
Dual Port Enterprise 3yr Warranty Hard Drive |
504062-B21 | |
| HP 146GB 6G SAS 10K SFF (2.5-inch)
Dual Port Enterprise 3yr Warranty Hard Drive |
507125-B21 | |
| HP 146GB 3G SAS 10K SFF (2.5-inch)
Dual Port Enterprise 3yr Warranty Hard Drive |
418367-B21 | |
| HP 72GB 6G SAS 15K SFF (2.5-inch)
Dual Port Enterprise 3yr Warranty Hard Drive |
512545-B21 | |
| HP 72GB 3G SAS 15K SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive | 418371-B21 | |
| HP 36GB 15K rpm Hot Plug SAS 2.5 Dual Port Hard Drive | 418369-B21 | |
| HP 120GB 3G SATA SFF (2.5-inch) Midline 1yr Warranty Solid State Drive | 572073-B21 | |
| HP 60GB 3G SATA SFF (2.5-inch) Midline 1yr Warranty Solid State Drive | 572071-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12244_na/12244_na.html |
||
| SAS Hot Plug SFF Midline (MDL) Drives | ||
| HP 500GB 6G SAS 7.2K rpm SFF (2.5-inch) Midline 1yr Warranty Hard Drive | 507610-B21 | |
| SATA Hot Plug SFF Entry (ETY) Drives | ||
| HP 250GB 3G SATA 5.4K rpm SFF (2.5-inch) Entry 1yr Warranty Hard Drive | 460355-B21 | |
| HP 120GB 1.5G SATA 5.4K rpm SFF (2.5-inch) Entry 1yr Warranty Hard Drive | 458924-B21 | |
| NOTE: SATA drives have a 1 year warranty. Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_na/13021_na.html | ||
| SATA Hot Plug SFF Midline (MDL) Drives | ||
| HP 500GB 3G SATA 7.2K rpm SFF (2.5-inch) Midline 1yr Warranty Hard Drive | 507750-B21 | |
| HP 160GB 3G SATA 7.2K rpm SFF (2.5-inch) Midline 1yr Warranty Hard Drive | 530888-B21 | |
| NOTE: SATA drives have a 1 year warranty. Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_na/13021_na.html | ||
| NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components. | ||
|
|
||
|
Networking |
Gigabit Ethernet Adapters | |
| HP NC112T PCI Express Gigabit Server Adapter |
503746-B21
|
|
| HP NC360T PCI-E Dual Port Gigabit Server Adapter |
412648-B21
|
|
| HP NC364T PCI-E Quad Port Gigabit
Server Adapter NOTE: There is a maximum of five NC364T PCI Express Quad Port Gigabit Server Adapter NICs allowed in this server. |
435508-B21
|
|
| HP NC373F PCI-E Multifunction 1000SX Gigabit Svr Adapter |
394793-B21
|
|
| HP NC373T PCI-E Multifunction Gigabit Server Adapter |
394791-B21
|
|
| HP NC375T PCI Express Quad Port Gigabit Server Adapter | 538696-B21 | |
| HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter |
458492-B21
|
|
| 10 Gigabit Ethernet Adapters | ||
| HP NC522SFP Dual Port 10GbE Gigabit
Server Adapter NOTE: A minimum of two Gigabytes (2 GB) of server memory is required per each NC522SFP adapter. NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately. |
468332-B21 | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs. | ||
|
|
||
| Riser Cage Options | HP 580/570G3/G4/585G2 US Redundant Power Supply |
348114-001
|
|
|
||
| Power Supplies |
CAUTION: Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at "www.hp.com/go/proliant-energy-efficient" In ProLiant Servers that have more than one power slot (bay), only same size power supplies are recommended. If non-matched power supplies are inserted you will get errors and operation will fail. | |
| Power Supplies | ||
| HP 580/570G3/G4/585G2 Redundant Power Supply | 348114-B21 | |
| NOTE: If you require a local power cord, please check the Power Specifications below for the appropriate country-specific power cord, or consult the Power Cord Matrix: http://www.hp.com/go/powercordmatrix |
|
|
Additional Options
| HP Insight Software | HP Insight Control server deployment | |
| HP Insight Control
suite No Media 1 Server including 1 year 24x7 Support License NOTE: Customer will receive a license entitlement certificate, which must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12631_na/12631_na.html |
452148-B22
|
|
| HP Insight Control
suite Software Media Kit NOTE: Insight Software DVD media without licenses. Contains HP System Insight Manager and Insight software products and components licensed by the Insight Control and Insight Dynamics suites. Uses an integrated installer to perform quick and accurate software installation and updates. |
436222-B21
|
|
| HP Insight Control for Linux | ||
| HP Insight Control
suite for Linux Media Kit NOTE: This optional Media pack DVD contains the ISO image for HP Insight Control Environment for Linux, HP System Insight Manager, HP Insight Power Manager, HP Insight Virtual Machine Management software, and an integrated installer. Servers must be acquired separately. NOTE: This Media pack is optional because the latest ISO image and latest updates may be downloaded at no cost from: http://www.hp.com/go/ice-linux (click on Download button). |
464422-B22
|
|
| HP Insight Control
suite for Linux 1 Server 1yr Support/Updates Software License NOTE: Electronic licenses can be used to purchase multiple licenses with a single activation key, and are available in all countries except China and Japan. Customers in China and Japan should order the physical equivalent. NOTE: Customer will receive a license entitlement certificate, which must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. |
464423-B22 | |
|
NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_na/13019_na.html |
||
|
|
||
| Storage Controllers | SAS Controllers | |
| Smart Array P212 Controller | ||
| HP Smart Array P212/256 Controller | 462834-B21 | |
| HP Smart Array P212/Zero Memory Controller | 462828-B21 | |
| NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13203_na/13203_na.html (HP Smart Array P212 Controller) |
||
| Smart Array P410 Controller | ||
| HP Smart Array P410/512 BBWC Controller | 462864-B21 | |
| HP Smart Array P410/256 Controller | 462862-B21 | |
| NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13201_na/13201_na.html (HP Smart Array P410 Controller) |
||
| Smart Array P411 Controller | ||
| HP Smart Array P411/512 BBWC Controller | 462832-B21 | |
| HP Smart Array P411/256 Controller | 462830-B21 | |
| NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13202_na/13202_na.html (HP Smart Array P411 Controller) |
||
| Smart Array P800 Controller | ||
| HP Smart Array P800 Controller | 381513-B21 | |
| HP 8484 to Mini SAS 33in Cable Assembly | 591734-B21 | |
|
NOTE: Needed to support internal drives on the HP ProLiant DL585 G6 with the Smart Array P800 Controller NOTE: Please see the following QuickSpecs for Technical Specifications
and additional information: |
||
| Optional Upgrades | ||
| HP Mini SAS to 8484 32in/35in
Cable Assembly |
496016-B21 | |
| SCSI HBA | ||
| HP Single Channel Ultra320 PCI-E SC11Xe Host Bus Adapter | 412911-B21 | |
| NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12566_na/12566_na.html (SC11Xe HBA) |
||
| HP StorageWorks U320e SCSI Dual Channel Host Bus Adapter | AH627A | |
| NOTE: Please refer to the HBA QuickSpecs for additional information at: http://www.hp.com/products/hba. | ||
|
|
||
|
Power Cords |
HP Mini SAS to 8484 32in/35in Cable Assembly |
496016-B21
|
|
|
||
| Tape Storage | Tape Drives | |
| USB Rack-Mount Tape Solutions | ||
| HP StorageWorks DAT 160 USB (1)
in 1U Rack-mount Kit NOTE: Pre-configured with one DAT 160 USB tape drive. |
AG703A | |
| HP StorageWorks DAT 160 USB Internal Tape Drive | Q1580A | |
| SAS Rack-Mount Tape Solutions | ||
| HP StorageWorks LTO-4
Ultrium 1760 (1) SAS Tape Drive in 1U Rack-mount Kit NOTE: Pre-configured with one LTO-4 Ultrium 1760 SAS tape drive. |
EH946A | |
| HP StorageWorks 1U SAS Rack Mount
Kit NOTE: Supports up to (2) half-height SAS tape drives. |
AE459A | |
| HP StorageWorks DAT 160 SAS Internal
Tape Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A) |
Q1587A | |
| HP StorageWorks Ultrium 448 SAS
Internal Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A) |
DW085A | |
| HP StorageWorks Ultrium 920 SAS
Internal Tape Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A) |
EH847A | |
| HP StorageWorks LTO-4 Ultrium 1760 SAS Internal WW Tape Drive | EH919A | |
| SCSI Rack-Mount Tape Solutions | ||
| HP StorageWorks LTO-4 Ultrium 1840 (1) SCSI Tape Drive in 3U Rack-mount Kit | EH926A | |
| HP StorageWorks Ultrium 448 (1)
SCSI Tape Drive in 1U Rack-mount Kit |
DW028B | |
| HP StorageWorks Ultrium 920 (1) SCSI Tape Drive in 1U Rack-mount Kit | EH903A | |
| NOTE: HP P212
Smart Array Controller SAS (462828-B21) is recommended for a dedicated HBA
for SAS tape connection. NOTE: For an up-to-date listing of the latest O/S and software support details for HP Ultrium tape drives, please visit: http://www.hp.com/go/connect NOTE: For the complete listing of Tape Drive offerings, please see: http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html |
||
| Tape Autoloaders | ||
| HP StorageWorks DAT Autoloader | ||
| HP StorageWorks DAT 72x10 Tape Autoloader | AE313B | |
| HP StorageWorks 1/8 G2 Tape Autoloader | ||
| HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader | AK377A | |
| HP StorageWorks 1/8 G2 Ultrium 920 SAS Autoloader | AH558A | |
| HP StorageWorks 1/8 Ultrium 448 G2 Tape Autoloader | AH164A | |
| HP StorageWorks MSL2024 1 Ultrium 448 Drive Library | AG116A | |
| NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions. | ||
| HP StorageWorks 1/8 G2 Tape Autoloader Rack Kit | AH166A | |
| NOTE: Please reference the Tape Autoloader QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs | ||
| Tape Libraries | ||
| HP StorageWorks MSL2024 Tape Library | ||
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1840 Tape Library | AJ033A | |
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SAS Tape Library | AK378A | |
| HP StorageWorks MSL2024 1 Ultrium 960 Drive Library | AG115A | |
| HP StorageWorks MSL2024 Ultrium 920 SAS Tape Library | AH559A | |
| HP StorageWorks MSL4048 Tape Library | ||
| HP StorageWorks MSL4048 1 LTO-4 Ultrium 1840 Tape Library | AJ035A | |
| HP StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SAS Tape Library | AK380A | |
| HP StorageWorks MSL4048 Ultrium 920 SAS Tape Library | AH560A | |
| NOTE: Please reference the MSL Tape Library QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs. | ||
|
|
||
| Disk-Based Backup | RDX Removable Disk Backup | |
| HP StorageWorks RDX500 External
Removable Disk Backup System NOTE: 500GB of Disk Storage. |
AJ935A
|
|
| NOTE: Please see
the HP RDX Removable Disk Backup System QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13036_na/13036_na.html |
||
| D2D Backup | ||
| HP StorageWorks D2D2502i Backup System |
EJ001A
|
|
| 1.5 TB of usable network disk backup capacity. | ||
| HP StorageWorks D2D2504i Backup System |
EJ002A
|
|
| 3.0 TB of usable network disk backup capacity. | ||
| HP StorageWorks Disk-to-disk 130 Backup System with LTO-3 Ultrium 920 SAS Tape Drive | EH952A | |
| NOTE: Please see the HP D2D Backup Systems QuickSpecs for additional information: http://www.hp.com/go/d2d | ||
|
|
||
| StorageWorks Options | NOTE: The following
is a list of all Fibre Channel Host Bus Adapters for Windows and Linux.
For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html |
|
| Brocade Fibre Channel HBAs |
||
| HP StorageWorks 41B PCIe 4Gb Fibre
Channel Single Port Host Bus Adapter |
AP767A | |
| HP StorageWorks 42B PCIe 4Gb Fibre
Channel Dual Port Host Bus Adapter |
AP768A | |
| HP StorageWorks 82B PCIe 8Gb Fibre
Channel Dual Port Host Bus Adapter |
AP770A | |
| HP StorageWorks 81B PCIe 8Gb Fibre
Channel Single Port Host Bus Adapter |
AP769A | |
| Emulex Fibre Channel HBAs |
||
| HP StorageWorks 81E 8Gb Single
Port PCI-e Fibre Channel Host Bus Adapter |
AJ762A | |
| HP StorageWorks 82E 8Gb Dual Port
PCI-e Fibre Channel Host Bus Adapter |
AJ763A | |
| HP StorageWorks FC2142SR 4Gb PCIe
Host Bus Adapter |
A8002A | |
| HP StorageWorks FC2242SR 4Gb PCIe DC Host Bus Adapte | A8003A | |
| QLogic Fibre Channel HBAs |
||
| HP StorageWorks 81Q PCI-e Fibre
Channel Host Bus Adapter |
AK344A | |
| HP StorageWorks 82Q 8Gb Dual Port
PCI-e Fibre Channel Host Bus Adapter |
AJ764A | |
| HP StorageWorks FC1142SR 4Gb PCIe
Host Bus Adapter |
AE311A | |
| HP StorageWorks FC1242SR 4Gb PCIe DC Host Bus Adapter | AE312A | |
|
|
||
| HP StorageWorks Modular Smart Array | MSA SAN Storage Arrays | |
| HP StorageWorks Modular Smart
Array 50 Enclosure NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12245_na/12245_na.html |
364430-B21 | |
| HP StorageWorks MSA60 Array NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12627_na/12627_na.html |
418408-B21 | |
| HP StorageWorks MSA70 Array NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12652_na/12652_na.html |
418800-B21 | |
| HP StorageWorks 2012sa Dual Controller
Modular Smart Array NOTE: Please see the Modular Smart Array 2000sa QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/13045_na/13045_na.html |
AJ753A | |
| HP StorageWorks 2012sa Single
Controller Modular Smart Array NOTE: Please see the Modular Smart Array 2000sa QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/13045_na/13045_na.html |
AJ752A | |
| HP StorageWorks D2600 Disk Enclosure NOTE: Please see the D2000 Disk Enclosure QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/13404_na/13404_na.html |
AJ940A | |
| HP StorageWorks D2700 Disk Enclosure NOTE: Please see the D2000 Disk Enclosure QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/13404_na/13404_na.html |
AJ941A | |
|
|
||
|
Uninterruptible Power Systems |
HP Rack-mountable UPS | |
| HP R/T3000 Uninterruptible Power System (UPS) | ||
| HP R/T3000 Low Voltage Uninterruptable Power System | AF452A | |
| HP R/T3000 High Voltage Uninterruptible
Power System |
AF453A | |
| HP R/T3000 2U Extended Runtime Module | AF455A | |
| NOTE: Please see
the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13417_na/13417_na.html |
||
| HP Rack-Mountable R5500 UPS | ||
| HP R5500 VA 3U INT Uninterruptible
Power System NOTE: Please see UPS QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/11871_na/11871_na.html |
AF416A | |
| NOTE: For additional information on HP Uninterruptable Power Systems please go to: www.hp.com/servers/rackups. | ||
|
|
||
|
Power Distribution Units |
Monitored PDUs | |
| HP Monitored Power Distribution Unit: Half Rack Version | ||
| HP Single Input 3 Phase 48A Monitored Power Distribution Unit | AF916A | |
| Modular PDUs | ||
| HP 24A Low Voltage Modular Power Distribution Unit | 252663-D71 | |
| HP 24A High Voltage Modular Power Distribution Unit | 252663-D72 | |
| HP 32A High Voltage Modular Power Distribution Unit | 252663-B31 | |
| HP 40A High Voltage Modular Power
Distribution Unit NOTE: This mPDU (252663-B21), 40A model has a hardwired input. |
252663-B21 | |
| HP 16A High Voltage Modular Power Distribution Unit | 252663-B24 | |
| NOTE: For additional information on HP Power Distribution Units including accessories please go to: www.hp.com/go/pdu (Worldwide) | ||
|
|
||
|
HP Rack Series |
Rack 10000 G2 series |
|
| HP S10614
(14U) Rack |
292302-B22 | |
| NOTE: It is mandatory
to use a shock pallet when shipping racks with equipment installed. NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). NOTE: Please see the Rack 10000 G2 QuickSpecs for Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. |
||
|
|
||
|
HP Rack Options |
Keyboards and Monitors |
|
| HP TFT7600 Rackmount Keyboard 17in Monitor |
AG052A |
|
| HP 1URackmount Keyboard with USB |
AG072A
|
|
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| Console switches (KVM) | ||
| HP 1x4 USB/PS2 KVM Console Switch |
AF611A
|
|
| HP 1x4 KVM Console 6ft PS2 Cable |
AF612A
|
|
| HP 1x4 KVM Console 6ft USB Cable |
AF613A
|
|
| HP 0x2x16 Server Console Switch
with Virtual Media |
AF600A | |
| HP 2x1x16 IP Console Switch with
Virtual Media |
AF601A | |
| HP 4x1x16 IP Console Switch with
Virtual Media |
AF602A | |
| HP 16 Port Serial Console Server |
AF101A | |
| HP Server Console 0x2x16 Port
Analog Switch |
AF617A | |
| HP Server Console 0x2x8 Port Analog Switch | AF616A | |
| HP 0x2x16 KVM Server Console Switch G2 with Virtual Media CAC Software | AF618A | |
| HP 0x2x32 KVM Server Console Switch G2 with Virtual Media CAC Software | AF619A | |
| HP 1x1Ex8 KVM IP Console Switch G2 with Virtual Media CAC Software | AF620A | |
| HP 2x1Ex16 KVM IP Console Switch G2 with Virtual Media CAC Software | AF621A | |
| HP 4x1Ex32 KVM IP Console Switch G2 with Virtual Media CAC Software | AF622A | |
| HP 48 Port Serial Console Server | AF102A | |
|
|
||
| USB Options | HP USB Standard Keyboard
US |
DT528A#ABA |
| HP 4GB USB Flash Media Key Kit | 580385-B21 | |
| NOTE: Blank USB media device is supported for use with ProLiant iVirtualization. USB media must be installed in the internal slot of the ProLiant server. Learn more at http://www.hp.com/go/proliantvirtualization | ||
|
|
||
| Service and Support
Offerings (HP Care Pack Services) |
Hardware Services On-site Service | |
| HP 3 year 4 hour 13x5 ProLiant
DL58x Hardware Support |
U4607E
| |
| HP 3 year 4 hour 24x7 ProLiant D58x Hardware Support |
U4608E
| |
| Hardware Services 6-Hour Call to Repair On-site Service | ||
| HP 3 year 6 hour 24x7 Call to Repair ProLiant DL58x Hardware Support |
U4609E
| |
| Installation & Start-up Services | ||
| HP Install ProLiant DL58x Service |
U4617E
| |
| HP Startup ProLiant DL58x Service |
U4618E
| |
| Support Plus | ||
| HP 3 year Support Plus Microsoft ProLiant DL58x Service |
U4619E
| |
| Support Plus 24 | ||
| HP 3 year Support Plus 24 Microsoft ProLiant DL58x Service |
U4620E
| |
| HP 3 year Support Plus 24 SuSE ProLiant DL58x Service |
U6316E
| |
| HP 3 year Support Plus 24 Red Hat Advanced Server DL58x Service |
U9239E
| |
| NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack. |
|
|
Memory
| NOTE: Standard memory configurations listed do not apply to "Factory Integrated Models." | |
| HP ProLiant DL585 G6 Models | |
|
Standard Memory (One
of the following, depending on Model)
NOTE: Memory must be installed in like-pairs,
i.e. two of the same size. |
|
| The following memory options are available from HP: | |
| 2 GB REG PC2-6400 2 x 1 GB Kit |
497763-B21
|
| 4 GB REG PC2-6400 2 x 2 GB Kit |
497765-B21
|
| 8 GB REG PC2-6400 2 x 4 GB Kit |
497767-B21
|
| 8 GB REG PC2-6400 2 x 4 GB Low Power Kit | 504351-B21 |
| 16 GB REG PC2-5300 2 x 8 GB | 408855-B21 |
| 64 GB REG PC2-5300 8 x 8 GB | 495605-B21 |
|
Standard Memory Configuration (2.2GHz model)
Total Memory = 4 GB |
||||||||
|
|
1 |
2 |
3 |
4 |
5 |
6 |
7
|
8
(Slot closest to processor) |
| Processor 1
Memory Bus |
1 GB
|
1 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
| Processor 2
Memory Bus |
1 GB
|
1 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
| Processor 3
Memory Bus |
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
| Processor 4
Memory Bus |
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
|
Standard Memory Configuration (2.3GHz model)
Total Memory = 8 GB |
||||||||
|
|
1 |
2 |
3 |
4 |
5 |
6 |
7
|
8
(Slot closest to processor) |
| Processor 1
Memory Bus |
1 GB
|
1 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
| Processor 2
Memory Bus |
1 GB
|
1 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
| Processor 3
Memory Bus |
1 GB
|
1 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
| Processor 4
Memory Bus |
1 GB
|
1 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
|
Standard Memory Configuration (2.4GHz and 2.5GHz
models)
Total Memory = 16 GB |
||||||||
|
|
1 |
2 |
3 |
4 |
5 |
6 |
7
|
8
(Slot closest to processor) |
| Processor 1
Memory Bus |
2 GB
|
2 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
| Processor 2
Memory Bus |
2 GB
|
2 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
| Processor 3
Memory Bus |
2 GB
|
2 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
| Processor 4
Memory Bus |
2 GB
|
2 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
| Example #1: Optional
Memory Configuration with DIMM mixing Standard Memory plus Optional Memory and Processors Total Memory = 34 GB | |||||||||
|
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 | |
| Processor
1 Memory Bus | 2
GB | 2
GB | 1
GB | 1
GB | 512
MB | 512
MB | 512
MB | 512
MB | |
| Processor
2 Memory Bus | 2
GB | 2
GB | 1
GB | 1
GB | 512
MB | 512
MB | 512
MB | 512
MB | |
| Processor
3 Memory Bus | 2
GB | 2
GB | 2
GB | 2
GB | 1
GB | 1
GB | 512
MB | 512
MB | |
| Processor
4 Memory Bus | 1
GB | 1
GB | 1
GB | 1
GB | 1
GB | 1
GB | 512
MB | 512
MB | |
| Example #2: Optional
Memory Configuration with Partial Bus Population Standard Memory plus Optional Memory and Processors Total Memory = 8 GB | |||||||||
| |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 | |
| Processor
1 Memory Bus | 512 MB | 512 MB | 512 MB | 512 MB | Empty | Empty | Empty | Empty | |
| Processor
2 Memory Bus | 512 MB | 512 MB | 512 MB | 512 MB | Empty | Empty | Empty | Empty | |
| Processor
3 Memory Bus | 512 MB | 512 MB | 512 MB | 512 MB | Empty | Empty | Empty | Empty | |
| Processor
4 Memory Bus | 512 MB | 512 MB | 512 MB | 512 MB | Empty | Empty | Empty | Empty | |
| Example #3: Maximum
Memory Configuration Maximum Memory (Standard replaced with Optional Memory) Total Memory = 256 GB | |||||||||
|
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 | |
| Processor
1 Memory Bus | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | |
| Processor
2 Memory Bus | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | |
| Processor
3 Memory Bus | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | |
| Processor
4 Memory Bus | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | 8 GB | |
|
|
Storage
![]() |
A | Ejectable: Slimline Diskette or Optical Drive (Optional) |
|
B | Ejectable: Slimline Optical Drive (DVD/CD-RW Standard) | |
| 1-8 | SFF SAS Internal Drive cage | |
|
|
|||
| Drive Support | |||
|
|
|||
|
Quantity |
Position |
Controller |
|
|
Ejectable Slimline Drives |
|
||
| 1.44-MB slimline Diskette Drive | Up to 1 | A or B Based on Boot Device Selector Switch |
Integrated |
| IDE Slimline DVD-ROM Drive (8X/24X) | Up to 2 | A or B | Integrated IDE |
| IDE Slimline CD-RW/DVD-ROM Combo Drive | Up to 2 | A or B | Integrated IDE |
| IDE DVD±R/RW 8X Drive | Up to 2 | A or B | Integrated IDE |
|
|
|||
| Hard Drives NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. |
|||
| SAS Hot Plug SFF Enterprise (ENT) Drives | |||
|
Quantity |
Position |
Controller |
|
| 300GB 6G SAS 10K DP 300GB 3G SAS
10K DP 146GB 6G SAS 15K DP 146GB 3G SAS 15K DP 146GB 6G SAS 10K DP 146GB 3G SAS 10K DP 72GB 6G SAS 15K DP 72GB 3G SAS 15K DP 72GB 3G SAS 10K DP |
Up to 8
|
1-8
|
HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
| SAS Hot Plug SFF Midline (MDL) Drives | |||
|
Quantity |
Position |
Controller |
|
| 500GB 6G SAS 7.2K DP |
Up to 8
|
1-8
|
HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
| SATA Hot Plug Entry (ETY) Drives | |||
|
Quantity |
Position |
Controller |
|
| 250GB 3G SATA 5.4K 120GB 1.5G SATA 5.4K |
Up to 8
|
1-8
|
HP Smart Array P800/512 BBWC Controller |
|
|
|||
| SATA Hot Plug Midline (MDL) Solid State Drives | |||
|
Quantity |
Position |
Controller |
|
| 60GB 3.0G SATA SSD 120GB 3.0G SATA SSD |
Up to 8
|
1-8
|
HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
|
External Storage |
|||
|
Quantity |
Position |
Host Controller or Adapter |
|
| 50 Modular Smart Array | Up to 4 |
External
|
HP Smart Array P800/512 BBWC Controller |
| 60 Modular Smart Array |
Up to 4
|
External
|
HP Smart Array P212/Zero Memory
Controller HP Smart Array P212/ 256 MB Controller |
| Up to 8 | HP Smart Array P800/512 BBWC Controller
HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
||
| 70 Modular Smart Array |
Up to 2
|
External
|
HP Smart Array P212/Zero Memory
Controller HP Smart Array P212/ 256 MB Controller |
| Up to 4 | HP Smart Array P800/512 BBWC Controller
HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
||
| HP 2000sa Modular Smart Array Controller | Up to 4 | External | HP SC08Ge Host Bus Adapter |
| D2600 Disk Enclosure | Up to 4 Up to 8 |
External | HP Smart Array P212/ 256 MB Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| D2700 Disk Enclosure | Up to 2 Up to 4 |
External | HP Smart Array P212/ 256 MB Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
|
|||
|
Maximum Storage Capacity - (External Enclosures Attached) | |
|
Internal |
2.4TB (8 x 300GB SFF SAS ENT drives) |
| External | 1120 TB (56 MSA60 enclosures @ 20 drives per enclosure x 1 TB SATA/SAS MDL Drives) |
| Total | 1122.4 TB |
| | |
| Tape and Disk-Based Backup | |||
|
NOTE: For a complete listing of compatible tape and disk-based backup offerings, please visit: www.hp.com/go/connect |
|
Position |
Controller |
Controller Part Number |
|
| HP StorageWorks SCSI Tape Drives,
External LTO-2 Ultrium 448 LTO-3 Ultrium 960 LTO-3 Ultrium 920 LTO-4 Ultrium 1760 LTO-4 Ultrium 1840 DAT 40 DAT 72 DAT 160 1U Rack-Mount Kit 3U Rack-Mount Kit |
External
|
HP SC11Xe Host Bus Adapter
|
412911-B21
|
|
HP StorageWorks USB Tape Drives, External |
External
|
USB 2.0 Port
|
N/A
|
| HP StorageWorks SAS Tape Drives,
External DAT 160 SAS LTO-2 Ultrium 448 SAS LTO-3 Ultrium 920 SAS LTO-4 Ultrium 1760 SAS LTO-4 Ultrium 1840 SAS 1U Rack-Mount Kit 3U Rack-Mount Kit |
External
|
HP Smart Array P212/Zero Memory Controller |
462828-B21
|
| HP StorageWorks SCSI Tape Automation,
External DAT 72x10 Autoloader 1/8 G2 Autoloader MSL2024 MSL4048 MSL8096 MSL6000 |
External
|
HP SC11Xe Host Bus Adapter HP U320e SCSI Host Bus Adapter NOTE: Recommended for MSL tape libraries. |
412911-B21
AH627A |
| HP StorageWorks SAS Tape Automation,
External 1/8 G2 Autoloader MSL2024 MSL4048 |
External
|
HP Smart Array P212/Zero Memory Controller |
462828-B21
|
| HP StorageWorks Fibre Tape
Automation, External MSL2024 MSL4048 MSL8096 MSL6000 |
External
|
Please consult the EBS connectivity matrix at: http://www.hp.com/go/ebs for detailed connectivity information. |
N/A
|
| HP StorageWorks RDX Removable
Disk Backup System RDX160 RDX320 RDX500 |
External
|
USB 2.0 Port |
N/A
|
| HP StorageWorks D2D Backup
Systems D2D120 D2D130 D2D2503i D2D4004i |
External
|
Embedded Network Controller
|
N/A
|
|
|
Power Specifications
| Part number | 348114-001 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Operational Input Voltage Range (Vrms) |
90 to 264
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Frequency Range (Nominal) (Hz) |
47 to 63 (50/60)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
NOTE: To review typical system power ratings use the HP Power Advisor which is available online located at url: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor
|
|||
|
|||||||
|
|
Technical Specifications
|
System Unit |
Dimensions (H x W x D) |
6.94 x 19 x 26.5 in (17.6 x 48.3 x 67.3 cm) | ||
|
Weight |
Maximum (all hard drives, power supplies, and processors installed) |
95 lb (43 kg) | ||
| Minimum (one hard drive, power supply, and processor installed) |
79 lb (36 kg) | |||
|
Input Requirements |
Rated Line Voltage | 90 - 132 VAC, 180 - 264 VAC |
||
| Rated Input Current | 12 A (at 100 VAC), 8 A (at 200 VAC) |
|||
| Rated Input Frequency | 47 to 63 Hz | |||
| Rated Input Power | 1161 W (at 100 VAC), 1598 W (at 200 VAC) |
|||
| BTU Rating | Maximum | 3985 BTU/hr (at 100 VAC), 5457 BTU/hr (at 200 VAC) |
||
| Power Specifications |
NOTE: To review typical system power ratings use the HP Power Advisor which is available online located at url: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor
|
|||
| Power Supply Output (per power supply) | Rated Steady-State Power | 910 W (at 100 VAC), 1300 W (at 200 VAC) |
||
| Maximum Peak Power | 960 W (at 100 VAC), 1420 W (at 200 VAC) |
|||
| System Inlet Temperature | Operating | 10° to 35°C (50° to
95°F) at sea level with an altitude derating of 1.0°C per every
305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050
m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the type and number of
options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). |
||
| Non-operating | -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). | |||
|
Relative Humidity |
Operating | 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. | ||
| Non-operating | 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. | |||
| Altitude | Operating | 3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | ||
| Non-operating | 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | |||
| Acoustic
Noise
|
Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). | |||
| Idle | ||||
| L WAd | 7.7 B | |||
| L pAm | 58 dBA | |||
| Operating | ||||
| L WAd | 7.7 B | |||
| L pAm | 58 dBA | |||
| Emissions Classification (EMC) |
FCC Rating | Class A | ||
| Normative Standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 | |||
| NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements. | ||||
|
| ||||
|
Slimline CD-RW/DVD-ROM 24X Combo Drive | Shipping Dimensions | 13.88 x 11.38 x 9.25 in (35.26 x 28.91 x 23.50 cm) | |||
|
Shipping Weight | 5 lb (2.27 kg) | ||||
| Disk |
Applicable Disk |
DVD-ROM | |||
|
DVD-R (Read Only) | |||||
|
2.6 GB/side DVD-RAM (Read Only) | |||||
|
5.2 GB/side DVD-RAM (Read Only) | |||||
|
CD-ROM Mode-1 data disc | |||||
| CD-ROM Mode-2 data disc | |||||
| CD Audio disc | |||||
| CD-Extra | |||||
| CD-RW | |||||
| CD-R | |||||
| CD Text | |||||
| PhotoCD | |||||
| CD-I (mode 2) | |||||
| CD-I Ready | |||||
| CD-Bridge | |||||
| Capacity |
DVD-ROM | DVD-SL | 4.7 GB/side | ||
| DVD-DL | 8.5 GB/side | ||||
| Double Sided | 9.40 GB/side | ||||
| DVD-R | 3.95 GB/side | ||||
| DVD-RAM | 2.6 GB/side and 5.2 GB/ | ||||
| CD-ROM | Mode-1 | 650 MB (550 MB) | |||
| Mode-2 | 742 MB (640 MB) | ||||
| Block Size | DVD | 2,048 bytes | |||
| CD | 2,352 (Mode-0) | ||||
| 2352, 2340,
2336, 2048 bytes (Mode-1) | |||||
| 2352,
2340, 2336, 2048 bytes (Mode-2) | |||||
|
Diameter | 120 mm, 80 mm (with adapter at vertical mounting mode) | ||||
| Loading Mechanism | Tray type |
| |||
| Interface |
EIDE (ATAPI) |
| |||
| Access Times (typical) | Random |
DVD-ROM < 120 ms, CD-ROM < 110 ms | |||
|
Full-Stroke |
DVD-ROM < 240 ms, CD-ROM < 160 ms | ||||
|
Audio Output Level (typical) |
Line-out | CD 0.7 Vrms at 47 Kohms Load | |||
| Data Transfer Rate (sustained) |
DVD-ROM | Single Layer | 10.8 MB/sec. Max. | ||
| DVD-RAM | 2.77 MB/sec. Max | ||||
| CD-ROM |
7.2 MB/sec. Max. | ||||
|
Cache Buffer | 2 MB | ||||
| Spin-up Time (typical) | less than 10 seconds |
| |||
| MTBF |
120,000 Power On Hours (POH) |
| |||
| Ambient Temperature |
Operating | -22° to 140° F (-30° to 60° C) | |||
| Relative Humidity | Operating |
10% to 80% | |||
| Storage/Transportation | 5% to 95% | ||||
| Dimensions |
(HxWxD, maximum) |
0.5 x 5.04 x 5.1 in (12.7 x 128 x 129.4 mm) | |||
| Option Kit Contents | DVD-ROM drive with installation guide, warranty card, registration card | ||||
| | |||||
| Integrated Lights-Out
2 Standard (integrated on system board) |
Architecture | 32-bit PCI-based health and remote management ASIC (Application Specific Integrated Circuit) |
| Processor | 32-bit RISC processor core running at 66 MHz | |
| Upgradeability | Option firmware upgradeable via flash ROM | |
| Video Support | Utilizes the host server's embedded video chip. Supports VGA/SVGA, 640 x 480 (256 to 16.7M colors), 800 x 600 (256 to 16.7M colors), 1024 x 768 (256 to 65K colors), 1280 x 1024 (256 colors) | |
| Interfaces | One Ethernet network connection (10/100 Mb/s) | |
| Memory | 2-MB Flash ROM | |
| 8-MB SDRAM | ||
| Operating System and Virtualization Software Support | Microsoft Windows Server Windows Server 2008 Hyper-V Red Hat Enterprise Linux (RHEL) SUSE Linux Enterprise Server (SLES) Oracle Enterprise Linux (OEL) Solaris 10 for x86/x64 based systems VMware XenSource NOTE: For more information on HP's Certified and Support Operating System & Virtualization Software, visit our Support Matrix at: www.hp.com/go/ossupport For our driver download page: www.hp.com/support/DL585G6 |
|
| Client Browser Support | Microsoft Internet Explorer 6.0 SP1 or later. | |
| Mozilla Firefox 2.0 or later (on supported Windows and Linux client systems) | ||
| Mozilla Firefox 1.75 or later (for supported Linux client systems) | ||
| iLO 2 Standard Features | Virtual Text Remote Console | |
| Virtual KVM | ||
| Virtual Power Button Control | ||
| Virtual UID Control | ||
| Power Regulator Control | ||
| Dedicated LAN Connectivity | ||
| Secure access using web browser | ||
| Secure access using Secure Shell (SSH) client | ||
| Serial connectivity | ||
| Automatic IP Configuration via DHCP/DNS/WINS | ||
| Industry Standard 128-bit Secure Sockets Layer (SSL) Security | ||
| IML and iLO2 Event Logging | ||
| Support for up to 12 user accounts with customizable access privileges | ||
| iLO Advanced Features (optional) | Virtual Graphical Remote Console | |
| Virtual Floppy/USB Key drive | ||
| Virtual CD-ROM drive | ||
| Directory Services Integration | ||
| Processor States Reporting | ||
| Terminal Services Integration | ||
|
|
||
|
Smart Array P410 Controller |
Disk Drive and Enclosure Interface - Transfer rate | 6Gb/s SAS (Serial Attached SCSI) 3Gb/s SATA (Serial ATA) |
| SAS Connectors | 2 internal (Mini-SAS) x8 wide port connectors | |
| Cache Memory Speed | DDR2-800MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s maximum bandwidth. | |
| Server Interface | x8 5G PCIe 2.0 provides 4GB/s maximum bandwidth. | |
| SAS Speed | x8 3G SAS provides 2.4GB/s maximum bandwidth. | |
| Cache Memory | 40-bit 256MB ECC protected cache (72-bit 512MB BBWC module upgrades available); transportable with battery-backed upgrade | |
| Logical Drives Supported | Up to 64 logical drives | |
| Maximum Logical Drive Capacity | Greater than 2TB | |
| Host Memory Addressing | 64-bit, supporting greater than 4GB server memory space | |
| RAID Support | RAID 6, 6+0 (Advanced Data Guarding) NOTE: The minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade is required to enable RAID 6, 6+0 |
|
| RAID 5, 5+0 (Distributed Data
Guarding) NOTE: The 256 MB is required to enable RAID 5, 5+0 support of the Smart Array P410i |
||
| RAID 1+0 (Striping & Mirroring) | ||
| RAID 0 (Striping) | ||
|
|
||
|
Two embedded NC371i Multifunction Gigabit Server Adapters | Network Interface | 10/100/1000-T | |
| Compatibility | IEEE 802.3 10Base-T | ||
| IEEE 802.3ab 1000Base-T | |||
| IEEE 802.3u 100Base-TX | |||
| Data Transfer Method | PCI Express, four lanes (x4) | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000 Mb/s | ||
| Connector | RJ-45 | ||
| Cable Support | 10Base-T | Categories 3, 4, or 5 UTP; up to 328 ft (100 m) | |
| 10/100/1000 Base-TX | Category 5 UTP up to 328 ft (100 m) | ||
| | |||
|
Environment-friendly Products and Approach | End-of-life Management and Recycling | Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
| | ||
| © Copyright 2009 Hewlett-Packard
Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows are US registered trademarks of Microsoft Corporation. AMD, the AMD Arrow logo, AMD Opteron™, and combinations thereof, are trademarks of Advanced Micro Devices, Inc. Unix is a registered trademark of The Open Group. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less. |