|
|
Overview
|
HP PCIe IO Accelerators for ProLiant Servers |
|
| HP IO Accelerator for ProLiant Servers is a PCIe card-based direct-attach solid state storage technology solution for application performance enhancement. Based on Multi-Level Cell (MLC) and Single Level Cell (SLC) NAND Flash technology, these devices are ideal for low latency workloads requiring high transaction rates and real-time data access. | |
![]() |
![]() |
| ioDrive (Genration2) | ioDrive Duo (Generation2) |
![]() |
![]() |
| ioDrive (Genration1) | ioDrive Duo (Generation1) |
|
|
|
| What's New |
|
|
|
| Models | ||
| HP I/O Accelerator Options | Second Generation Accelerators |
|
| HP 365GB Multi Level Cell G2
PCIe ioDrive2 for ProLiant Servers |
673642-B21 | |
| HP 785GB Multi Level Cell G2
PCIe ioDrive2 for ProLiant Servers |
673644-B21 | |
| HP 1205GB Multi Level Cell G2 PCIe ioDrive2 for ProLiant Servers | 673646-B21 | |
| HP 2410GB Multi Level Cell G2 PCIe ioDrive2 Duo for ProLiant Servers | 673648-B21 | |
| First Generation Accelerators |
||
| HP 160GB Single Level Cell PCIe
ioDrive for ProLiant Servers |
600278-B21 | |
| HP 320GB Multi Level Cell PCIe
ioDrive for ProLiant Servers |
600279-B21 | |
| HP 320GB Single Level Cell PCIe
ioDrive Duo for ProLiant Servers |
600281-B21 | |
| HP 640GB Multi Level Cell PCIe
ioDrive Duo for ProLiant Servers |
600282-B21 | |
| HP 1.28TB Multi Level Cell PCIe ioDrive Duo for ProLiant Servers | 641027-B21 | |
|
|
Compatibility
| Compatibility | |
| First Generation Accelerators Support |
ProLiant DL (rack-optimized):
ProLiant ML (expansion-optimized):
ProLiant SL (Scalable System)
NOTE: This is a list of supported servers. Some may be discontinued. |
|
|
|
| Second Generation Accelerators Support |
ProLiant DL (rack-optimized):
ProLiant ML (expansion-optimized):
NOTE: This is a list of supported servers. Some may be discontinued. |
|
|
Standard Features
| What is an IO Accelerator? | The IO Accelerator is an PCIe card-based, advanced storage device that uses solid state storage technology directly on the PCI bus, assuring high read and write data rates and accelerated application performance. The associated application performance improvements will have a positive impact on business results and the ability to accelerate IO-bound workloads like databases, virtualization and data analytics, resulting in significant cost and time savings. |
|
|
|
| Single Level Cell and Multilevel Cell | NAND technology uses flash memory cells to store data. Single level Cell (SLC) stores one bit per cell, while Multi-level Cell (MLC) uses two bits per cell. While MLC can store more data within each device, it has lower endurance characteristics than SLC. |
|
|
|
| IO and Read/Write Performance | HP PCIe IO Accelerators offer superior IO performance up to 892,000 READ IOPS and 935,000 WRITE IOPS, and high throughput up to 3.0 GB/s READ and up to 2.5 GB/s WRITE. |
|
|
|
| Latency | HP PCIe IO Accelerators offer very low latency access to data, as low as 15 microseconds to write a 4K block and as low as 68 microseconds to read a 4K block. In other words, a virtually zero seek time compared to rotating magnetic media. |
|
|
|
| RAM Requirements | The amount of free RAM required by the driver depends on the size of the blocks used when writing to the drive. The smaller the blocks, the more RAM required. Here are the guidelines for each 100GB of storage: | |
| Average Block Size (bytes) |
System RAM usage (Megabytes) per 100GB of storage for Driver version 2.x and 3.x | |
| 8,192 | 280MB | |
| 4,096 (most common) | 530MB | |
| 2,048 | 1030MB | |
| 1,024 | 2,000MB | |
| 512 | 3,970MB | |
|
|
||
| Manageability |
Command Line (CLI) tools for both Linux and Windows to configure, monitor,
and upgrade firmware |
|
|
|
| PCI IDs |
Vendor & Device ID 1AED:1005; Subsystem Vendor & Device ID 103C:324E |
|
|
|
| Upgradeability |
The controller for the HP IO Accelerators can be upgraded in the future with new firmware. Online firmware update tools are available for all supported operating systems. |
|
|
|
| Wear-leveling |
NAND Flash devices use semiconductor technology that has a finite number of data that can be written to the device, defined as the Maximum Lifetime. Projected lifetime of the NAND storage due to wear-out varies with type of NAND and amount of writes to the device. |
|
|
|
| Maximum usage |
ioDrive |
ioDrive Duo | |||
| 160GB | 320GB | 320GB | 640GB | 1.28TB | |
| 75 PB writes | 4 PB writes | 150 PB | 8 PB writes | 8 PB writes | |
| ioDrive2 |
ioDrive2 Duo | ||||
| 365GB |
785GB |
1205GB |
2410GB |
||
| 4 PB written | 11 PB written | 17 PB written | 34 PB written |
||
| NOTE: Subject to maximum usage limitations. Parts and components that have exceeded their maximum supported lifetime and/or the maximum usage limitations. Maximum supported lifetime-the period in years set to equal the warranty for the device. Maximum usage limit-This is the maximum amount of data that can be written to the device before write burn-out. | |||||
|
|
|||||
| Data Integrity |
Using advanced ECC techniques, the HP IO Accelerators can correct up to 11 bits out of every 240 bytes, with a design target of a 1 in 10 to the 20th Power probability of uncorrectable data and a 1 in 10 to the 30th Power probability of undetected bad data. |
|
|
|
| OS Support |
RHEL 4,5,6 (64-bit support only) |
| SLES 10, 11 (64-bit support only) | |
| Windows Server x86-64 2003, 2008 (64-bit support only) | |
| Oracle Enterprise Linux 5 (OEL 5) | |
| CentOS | |
| VMware ESX 4.0 Update 1 | |
| NOTE: The HP IO Accelerators are currently not supported as boot devices. | |
|
|
|
| Configurations |
Mixing of capacities is allowed, OS RAID |
|
|
|
| Warranty | 3/0/0 warranty; Customer Self Repair (CSR) Subject to maximum usage limitations (Please see note under Additional Services Information). |
|
|
Service and Support
| Service and Support |
HP Technology Services Protect your business beyond warranty with HP Care Pack Services HP Foundation Care services deliver scalable support-packages for HP
industry-standard servers and software. You can choose the type and level
of service that is most suitable for your business needs. New to this
portfolio is HP Collaborative Support. If you are running business critical
environments, HP offers Proactive Care or Critical Advantage. These services
help you deliver high levels of application availability through proactive
service management and advanced technical response.
|
|
|
|
| Recommended HP Care Pack Services for optimal satisfaction with your HP product | |
| Recommended Services |
3-Year HP 24x7 4 hour Response, Proactive Care http://h20195.www2.p.com/V2/GetPDF.aspx/4AA3-8232ENW.pdf |
|
|
|
| Related HP Care Pack Services to enhance your HP product experience | |
| Related Services |
3-Year HP 24x7 4 hour Response, Proactive Care 3-Year HP 6-hour Onsite Call-to-Repair, HP Collaborative Support |
|
|
|
| Insight Remote Support |
Provides 24 X 7 remote monitoring, proactive notifications, and problem resolution. Learn more http://www.hp.com/go/insightremotesupport |
|
|
|
| HP Support Center |
Personalized online support portal with access to information, tools and experts to support HP business products. Submit support cases online, chat with HP experts, access support resources or collaborate with peers. Learn more http://www.hp.com/go/hpsc HP's Support Center Mobile App*
allows you to resolve issues yourself or quickly connect to an agent for
live support. Now, you can get access to personalized IT support anywhere,
anytime. *HP' Support Center Mobile App is subject to local availability |
|
|
|
| Parts and materials |
HP will provide HP-supported replacement parts and materials necessary to maintain the covered hardware product in operating condition, including parts and materials for available and recommended engineering improvements. Supplies and consumable parts will not be provided as part of this service; standard warranty terms and conditions apply. Parts and components that have exceeded their maximum supported lifetime and/or the maximum usage limitations as set forth in the manufacturer's operating manual or the technical product data sheet will not be provided, repaired or replaced as part of this service. |
|
|
|
| Warranty / Service Coverage |
For ProLiant servers and storage systems, this service covers HP-branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as external monitors up to 22" and tower UPS products; these items will be covered at the same service level and for the same coverage period as the server unless the maximum supported lifetime and/or the maximum usage limitation has been exceeded. Coverage of the UPS battery is not included; standard warranty terms and conditions apply. The defective media retention service feature option applies only to Disk or eligible SSD/Flash Drives replaced by HP due to malfunction. It does not apply to any exchange of Disk or SSD/Flash Drives that have not failed. SSD/Flash Drives that are specified by HP as consumable parts and/or that have exceeded maximum supported lifetime and/or the maximum usage limit as set forth in the manufacturer's operating manual or the technical data sheet are not eligible for the defective media retention service feature option. |
|
|
|
| For more information |
To learn more on services for HP ESSN Options, please contact your HP sales representative or HP Authorized Channel Partner. Or visit: http://www.hp.com/services/proliant or www.hp.com/services/bladesystem |
|
|
Technical Specifications
| HP 2410GB Multi
Level Cell G2 PCIe Solid State Drive IO Accelerator 673648-B21 |
Usable Capacity | 2410GB |
| Technology | NAND Flash, MLC | |
| Bandwidth (1MB) | 2.5GB/s Writes, 3.0GB/s Reads | |
| Access Latency | 15 microseconds for Writes, 68 microseconds for Reads | |
| IOPS | Read 892,000 IOPS (sequential
512B), Write 935,000 IOPS (sequential 512B) Read 285,000 IOPS (random 512B), Write 725,000 IOPS (random 512B) |
|
| Form factor | Full Height/Half length PCI Express x 8 slot (spec 2.0) | |
| Bus Interface | PCI Express 2.0 x 8 | |
| Power (Nominal) | PCI Express 2.0 x 8 | |
| Operating Temperature | 0-55°C (Operational)/-40-70°C (non-operational) | |
| Supported Driver Version | 3.x and higher | |
| Auxillary Power (for ioDrive2 Duo only) |
NOTE: This SKU may require auxiliary power to achieve maximum performance. Included in the box is a power cable kit that will plug into the Duo and into a GPU power cable kit for the server (which is not included with the Duo). Please refer to the Quickspec of the applicable server to determine which GPU power cable kit from HP is required. | |
|
|
||
| HP 1205GB Multi
Level Cell G2 PCIe Solid State Drive IO Accelerator 673646-B21 |
Usable Capacity | 1205GB |
| Technology | NAND Flash, MLC | |
| Bandwidth (1MB) | 1.3GB/s Writes, 1.5GB/s Reads | |
| Access Latency | 15 microseconds for Writes, 68 microseconds for Reads | |
| IOPS | Read 445,000 IOPS (sequential
512B), Write 535,000 IOPS (sequential 512B) Read 143,000 IOPS (random 512B), Write 535,000 IOPS (random 512B) |
|
| Form factor | Half Height/Half length-Low profile PCI Express x 4 slot (spec 2.0) | |
| Bus Interface | PCI Express x 4 | |
| Power (Nominal) | PCI Express x 4 (power spec 2.0) | |
| Operating Temperature | 0-55°C (Operational)/-40-70°C (non-operational) | |
| Supported Driver Version | 3.x and higher | |
|
|
||
| HP 785GB Multi
Level Cell G2 PCIe Solid State Drive IO Accelerator 673644-B21 |
Usable Capacity | 785GB |
| Technology | NAND Flash, MLC | |
| Bandwidth (1MB) | 1.1GB/s Writes, 1.5GB/s Reads | |
| Access Latency | 15 microseconds for Writes, 68 microseconds for Reads | |
| IOPS | Read 443,000 IOPS (sequential
512B), Write 535,000 IOPS (sequential 512B) Read 141,000 IOPS (random 512B), Write 535,000 IOPS (random 512B) |
|
| Form factor | Half Height/Half length-Low profile PCI Express x 4 slot (spec 2.0) | |
| Bus Interface | PCI Express x 4 | |
| Power (Nominal) | PCI Express x 4 (power spec 2.0) | |
| Operating Temperature | 0-55°C (Operational)/-40-70°C (non-operational) | |
| Supported Driver Version | 3.x and higher | |
|
|
||
| HP 365GB Multi
Level Cell G2 PCIe Solid State Drive IO Accelerator 673642-B21 |
Usable Capacity | 365GB |
| Technology | NAND Flash, MLC | |
| Bandwidth (1MB) | 590MB/s Writes, 900MB/s Reads | |
| Access Latency | 15 microseconds for Writes, 68 microseconds for Reads | |
| IOPS | Read 415,000 IOPS (sequential
512B), Write 535,000 IOPS (sequential 512B) Read 137,000 IOPS (random 512B), Write 535,000 IOPS (random 512B) |
|
| Form factor | Half Height/Half length-Low profile PCI Express x 4 slot (spec 2.0) | |
| Bus Interface | PCI Express x 4 | |
| Power (Nominal) | PCI Express x 4 (power spec 2.0) | |
| Operating Temperature | 0-55°C (Operational)/-40-70°C (non-operational) | |
| Supported Driver Version | 3.x and higher | |
|
|
||
| HP 160GB Single
Level Cell PCIe ioDrive for ProLiant Servers 600278-B21 |
Usable Capacity | 160GB |
| Technology | NAND Flash, SLC | |
| Bandwidth (64kB) | 770 MB/s Writes 770MB/s Reads | |
| Access Latency (512 Byte) | 26 microseconds | |
| IOPS | 123,000 IOPS (75/25 R/W) | |
| Form factor | Half Height/Half length-Low profile PCI Express x 4 slot (spec 1.1) | |
| Bus Interface | PCI Express x 4 | |
| Power (Nominal) | PCI Express x 4 (power spec 1.1) | |
| Operating Temperature | 0-55°C (Operational)/-40-70°C (non-operational) | |
| Supported Driver Version |
2.x and higher. NOTE: For interoperability with the new IO Accelerator G2 SKUs, you must use a 3.x or higher driver. If upgrading from 2.x to 3.x, you must back up your data first, as a low-level format occurs during the upgrade process and all data will be lost. |
|
|
|
||
| HP 160GB SLC PCIe
ioDrive 600278-B21 |
Usable Capacity | 160GB |
| Technology | NAND Flash, SLC | |
| Bandwidth (64kB) | 750 MB/s Writes 770MB/s Reads | |
| Access Latency (512 Byte) | 26 microseconds | |
| IOPS | 123,000 IOPS (75/25 R/W) | |
| Form factor | Half Height/Half length-Low profile PCI Express x 4 slot (spec 1.1) | |
| Bus Interface | PCI Express x 4 | |
| Power (Nominal) | PCI Express x 4 (power spec 1.1) | |
| Operating Temperature | 0-55°C (Operational)/-40-70°C (non-operational) | |
|
|
||
| HP 320GB Multi
Level Cell PCIe ioDrive for ProLiant Servers 600279-B21 |
Usable Capacity | 320GB |
| Technology | NAND Flash, MLC | |
| Bandwidth (64kB) | 510MB/s Writes 735MB/s Reads | |
| Access Latency (512 Byte) | 29 microseconds | |
| IOPS | 67,000 IOPS (75/25 R/W) | |
| Form factor | Half Height/Half length-Low profile PCI Express x 4 slot (spec 1.1) | |
| Bus Interface | PCI Express x 4 | |
| Power (Nominal) | PCI Express x 4 (power spec 1.1) | |
| Operating Temperature | 0-55°C (Operational)/-40-70°C (non-operational) | |
| Supported Driver Version | 2.x and higher. NOTE: For interoperability with the new IO Accelerator G2 SKUs, you must use a 3.x or higher driver. If upgrading from 2.x to 3.x, you must back up your data first, as a low-level format occurs during the upgrade process and all data will be lost. |
|
|
|
||
| HP 320GB Single
Level Cell PCIe ioDrive Duo for ProLiant Servers 600281-B21 |
Usable Capacity | 320 GB |
| Technology | NAND Flash, SLC | |
| Bandwidth (64kB) | 1.5GB/s Writes 1.5GB/s Reads | |
| Access Latency (512 Byte) | 26 microseconds | |
| IOPS | 238,000 (75/25 R/W mix) | |
| Form factor | Full Height/Half Length PCI Express 2.0 | |
| Bus Interface | PCI Express x 8 or PCI Express 2.0 x 4 | |
| Power (Nominal) | PCI Express power spec 2.0 | |
| Operating Temperature | 0-55°C (Operational)/-40-70°C (non-operational) | |
| Supported Driver Version | 2.x and higher. NOTE: For interoperability with the new IO Accelerator G2 SKUs, you must use a 3.x or higher driver. If upgrading from 2.x to 3.x, you must back up your data first, as a low-level format occurs during the upgrade process and all data will be lost. |
|
|
|
||
| HP 640GB Multi
Level Cell PCIe ioDrive Duo for ProLiant Servers 600282-B21 |
Usable Capacity | 640GB |
| Technology | NAND Flash, MLC | |
| Bandwidth (64kB) | 1.0GB/s Writes 1.5GB/s Reads | |
| Access Latency (512 byte) | 29 microseconds | |
| IOPS | 138, 000 IOPS (75/25 R/W mix) | |
| Form factor | Full Height/Half Length PCI Express 2.0 | |
| Bus Interface | PCI Express x 8 or PCI Express 2.0 x 4 | |
| Power (Nominal) | PCI Express power spec 2.0 | |
| Operating Temperature | 0-55°C (Operational)/-40-70°C (non-operational) | |
| Supported Driver Version | 2.x and higher. NOTE: For interoperability with the new IO Accelerator G2 SKUs, you must use a 3.x or higher driver. If upgrading from 2.x to 3.x, you must back up your data first, as a low-level format occurs during the upgrade process and all data will be lost. |
|
|
|
||
| HP 1.28TB Multi
Level Cell PCIe ioDrive Duo for ProLiant Servers 641027-B21 |
Usable Capacity | 1.28TB |
| Technology | NAND Flash, MLC | |
| Bandwidth (64kB) | 1.1GB/s Writes 1.5GB/s Reads | |
| Access Latency (512 Byte) | 30 microseconds | |
| IOPS | 150, 000 IOPS (75/25 R/W mix) | |
| Form factor | Full Height/Half Length PCI Express 2.0 | |
| Bus Interface | PCI Express x 8 or PCI Express 2.0 x 4 | |
| Power (Nominal) | PCI Express power spec 2.0 | |
| Operating Temperature | 0-55°C (Operational)/-40-70°C (non-operational) | |
| Supported Driver Version |
2.x and higher. NOTE: For interoperability with the new IO Accelerator G2 SKUs, you must use a 3.x or higher driver. If upgrading from 2.x to 3.x, you must back up your data first, as a low-level format occurs during the upgrade process and all data will be lost. |
|
|
|
||
| Environment-friendly Products and Approach | End-of-life Management and Recycling | Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
|
|
||
|
© Copyright 2012 Hewlett-Packard Development Company, L.P. |